Home

IDEC FL1E Series Smart Relays

image

Contents

1. Operational Control Buttons Program with just the push of a button SmartRelay control buttons can be used to program modify and change preset parameters The four cursor keys can also be configured as inputs as needed berT Digital Outputs IDEC SmartRelays are equipped with four relay outputs rated at 10A pt Using digital expansion modules you can configure a maximum of sixteen outputs Phone 800 894 0412 Fax 888 723 4773 Web EEPROM Memory With IDEC SmartRelays your program is stored in a non volatile EEPROM Memory New Extended Retentive Data Memory Extended memory gives you up to 250 bytes of retentive data memory More than 4 times that of FL1D New Arithmetic Functions Analog Math function blocks allow basic arithmetic operations such as addition subtraction multiplication and division Password Protection Concerned about your program being copied or altered IDEC SmartRelays keep you safe with a unique password protection scheme allowing end users to access certain parameters without seeing or modifying the actual program Additional text display For the first time ever you can connect an external text display to your smartRelay making it easy for you to monitor view and troubleshoot from outside your panel Turn to page 7 to learn more Quality IDEC has built a reputation based on providing high quality dependable products you can trust and our SmartRelays are no exception Each model is CULus li
2. Find Us Visit IDEC website for additional information on FREE software upgrades demo software FAQs manuals and brochures Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Part numbers FL1E Base Modules ketal Communication Modules 1 0 Expansion Modules Starter Kits amp Accessories Part Numbers Rated Voltage Input Signal Input Type Output Type With Clock FL1E H12RCE 12 24V DC DC PNP Relay Yes With LCD FL1E H12SND 24V DC Transistor Source Display FL1E H12RCA 24V AC DC NPN PNP AC DC Relay Yes FLIE H12RCC 100 240V AC DC PNP Without FLIE B12RCE 12 24V DC DC PNP Yes LCD FL1E B12RCA 24V AC DC NPN PNP Relay Display AC DC Yes FL1E B12RCC 100 240V AC DC PNP Part Number Rated Voltage Description FL1E RD1 12 VDC 24 VAC DC FL1E SmartRelay Text Display Part Numbers Module Input Power Total 1 0 Input 16 points FL1B CL1C12 LonWorks Communication Module 24V AC DC Analog Input 8 points Output 12 points FL1B CAS2 AS Interface Communication Module 30V DC Apur t paini Output 4 points LonWorks is a registered trademark of Echelon Part Numbers Module Rated Voltage Input Type Output Type Total 1 0 FL1B M08B2R2 12 24V DC Relay FL1B M08B1S2 inati 24V DC PNP Transistor Combination 8 4 in 4 Out FL1B M08C2R2 1 0 100 240V AC DC F ela FL1B M08D2R2 24V AC DC NPN PNP t FL1B J2B2 Analog Input 12 24V DC 0 10V 4 20mA 2 2 in 0 Out FL1D K2B2 Analog Output 24V DC 0 10V 2
3. VIDEC Think Automation and beyond E iU T ry TE ry IH 09000 eoooee IDEC SmartRelay Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com IDEC SmartRelay 1 I a 7 E Ti l i P H i La i i ha mi a ri r Irr ose Smear tRelay Increase your versatility with a new remote display Look around IDEC SmartRelays are in everything from lighting controls to ice making machines and grocery store misters Proving reliable time after time these intelligent logic modules are the ideal controller for simple automation tasks A new fifth generation of smartRelays offer functions to give you even more flexibility and convenience Advances include extended memory a brighter display with higher LCD contrast improved analog and high speed inputs an external Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Vaca INPUT AJALOOL The Intelligent Choice text display and upgraded programming software With an ever changing market and tough competition you need an edge to stay on top SmartRelay has a new HMI text display panel to do just that This economical interface lets you make quick adjustments while at the same time making it easy to spot and troubleshoot failures using built in operator functions and diagnostics So why wait Make the smart choice IDEC SmartRelay Industrial Facility Systems Unique Solutions
4. 0 in 2 Out Part Numbers Description SMARTSTART BAC E SMARTSTART BDC E SMARTSTART HAC E SMARTSTART HDC E FL9Y LP1CDW FLIA PC1 FL1E PC2 FL1E PM4 FL1E PB1 FL1E PG1 FC4A USB FL9Y B1090 0 FL1B Y1371 SW8 Starter Kits Accessories FL1E B12RCC WindLGC software and programming cable FL1E B12RCE WindLGC software programming cable and simulator switch FL1E H12RCC WindLGC software and programming cable FL1E H12RCE WindLGC software programming cable and simulator switch WindLGC 6 0 programming software smartRelay Serial programming cable SmartRelay USB programming cable direct FL1E SmartRelay memory cartridge FL1E SmartRelay battery cartridge FL1E SmartRelay memory and battery combination cartridge Serial to USB converter FL1E SmartRelay user s manual 8 pt simulator switch used with 12 24VDC 24VDC base module only Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ia A f g eae 2 Fra EITE A ION aO i ToN ii VOOGT Our comprehensive line of automation products along with personalized service and support provide reliable solutions for even your most complex applications Everything from precision sensors to high capacity power supplies bright and compact touchscreens our new FL1E SmartRelays and even the fast MicroSmart Pentra are designed to work together to make your job easier So call IDEC today and get ready to find the customized answer to your speci
5. can be used Modify and change preset parameters or as push buttons for turning on the back scroll the screen with just the push of a light or for starting and stopping programs button Each button has the same functions as the base unit and can also be configured as inputs as needed Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Expand your possibilities In Id 16 26 ft 18 M II I i219 14 Le coocoo 000000 cococo ry24VDC Ii I2 ATS ATA io tovi INPUT s00 Iis All AT 0 104 T e foec Smarthelay joec pec gil H Au ji E UNST e e rs FL sei S2 i RES ETET E ih i i FLIE HIZACE Esc Dni Eais alea HT 4cRELET SA pumpu Hii OUTPUT 4cHELAVIQA is Analog Solutions IDEC SmartRelay is not limited to simple digital 1 0 controls With four built in 0 10V analog inputs compared with only two in FL1D you don t have to spend more money to connect your analog devices Inputs 17 18 11 and 2 can be configured as analog inputs Al1 through Al4 Additional analog I O expansion modules can be utilized to allow the FL1E SmartRelay to expand up to 10 analog inputs and 2 analog outputs Sensors flow meters pressure transducers and many other analog devices can be utilized in the SmartRelay system to give you more power and flexibility without added cost FL1B J2B2 e 2 pt analog input module e Up to four modules can be configured e Accep
6. com Email info clrwtr com Connect a new remote text display for added convenience eeeeceeseoe one SmertRelsy Adjustable Backlit LCD Display System status input output analog values timers and counters can be monitored through the 4x12 display It doesn t get any easier than this Now you can easily adjust settings view status and troubleshoot failures using a remote text message display The IDEC SmartRelay base and text display panel are indepen dent from each other allowing you to choose if message will be displayed on the internal or external display or both With a backlit LCD 128 x 64 pixels for easy viewing the FL1E text display panel can show up to 50 message blocks and is capable of displaying 4x12 characters A scrolling feature allows up to 24 character messages across the screen Plus this intuitive visual interface supports analog values such as level sensor flow rate rom counts temperature and more on horizontal and vertical bar graphs Six predefined cursor keys make screen navigation and data entry along with four user defined function buttons configu rable to your desired equipment operation The FL1E text display panel is IP65 and NEMA 4 4X rated for indoor wash down environments as well as being certified with industry standard agency approval cULus and FM Class 1 Div 2 FIDEC Programmable Function Keys aene ates Operational Control Buttons Four membrane switches that
7. e Conveyor systems e Elevator controls e Exhaust and filtering systems e Automatic food dispensing machines e Water treatment and Irrigation systems e Motor pump and valve controls e Solar electric systems e Marine systems e Extreme environmental conditions e Display panels and traffic light controls e Energy management Housing and Building Management Monitoring Systems e Lighting controls outside and inside e Door and gate controls e Heating and cooling systems e Shutter sun blind and awning controls e Water and sprinkler systems e Ventilation systems e Access controls e Alarm systems e Limit level monitoring e Parking Lot monitoring e Baggage control Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Control at your fingertips New Built in Analog Inputs Each SmartRelay is equipped with 8 digital inputs that can be used for your applications New in the FL1E 12 24VDC and 24VDC models eS els New Faster Inputs E G mame oe 3 are four built in analog inputs Inputs 11 12 17 and 18 can now be FL1E can support up to four SKHz high speed inputs You configured to accept 0 10V analog signals Using expansion modules have the option of configuring inputs 13 14 I5 and l6 as you can utilize a maximum of 24 digital and 8 analog inputs fast counter inputs to give you even more flexibility Universal Voltages one cececcsccccnccecascccccceescoccccesevcis a 0000000
8. 00000000000000000000000090000006000 00000020 Available in 12 24V DC for solar and vehicle applications and 24V AC DC for building automation as well as 100 240V AC DC SmartRelay can be used for a wide variety of applications DIN Rail or Surface Mountable eeeeeeeeeeeeeeeeeeeereeeeeeeeeeeeeeeeeeeeereneeeeeee 7 cosceooooooocoocooooocooooocoooosoocooooosooooosoocooooseooooooooooooosoocooooocoocosecocoooocooocoosoocooooooooo New Controllable Backlit LCD Display FL1E SmartRelays have a built in LCD display with a brighter higher contrast screen you can adjust to your own preference System status input output analog values timers and counters can be monitored through the 4x12 LCD screen or you can display a predefined message with up to 48 characters chosen from 103 special character types Non LCD versions are also available New 50 More Memory FL1E SmartRelays offer an expanded program memory of 200 function blocks This is a 50 increase compared to the existing FL1D series Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com eeeeccccsccccccccece New Memory Cartridges Three memory cartridges are now available for FL1E Violet Green and Brown Violet is a 32K high capacity removable program memory card Green is a battery card that supports a Real Time Clock power supply for up to two years Brown is a combined memory battery card Memory and Battery Memory Battery
9. fic requirements ELLLILILETE Ol Touchscreens Automation Software Photoelectric sensors Power Supplies Programmable logic controllers PLC IDEC Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com
10. st and most effective programmable control based industrial networking protocols used in automation systems worldwide Reducing the amount of engineering by employing simpler wiring this module also enhances your operations by requiring little to no maintenance Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Program in seconds SmartRelay Software WindLGC is the exclusive programming software for the IDEC SmartRelay using Windows e Create Create simulate test and save your program using drag and drop functions Eight basic functions make It easy to create a simple switching program in just a matter of seconds while 31 additional special functions make it just as uncomplicated to create complex programs Choose function block diagrams UER LEETE Lents 65 dii vee he or ladder programming you can always convert from one to the other with the click of an icon mamn e Simulate Offline program simulation without the need for an actual SmartRelay enables testing of the entire program from a PC e Jest Once you verify your control program works in Simulation Mode WindLGC allows you to directly monitor your IDEC SmartRelay during operation using an Online Test mode e Document You can create and save your WindLGC program as a PDF BMP or JPG file Professional documentation is included with all the necessary configuration information such as comments and program settings
11. sted CE certified EMC compliant FM approved for Class 1 Div 2 hazardous locations C tick compliant Lloyds Registered and ABS approved Pe qe Uys O lt a gt CE APPROVED eo www clrwtr com Email info clirwtr com Making things easier rec Sie elay E 1 y Select Program from the main menu Create your control logic ope Sma thak Select Start and you re done Why worry about individual components like relays timers and counters when one IDEC SmartRelay has everything you need reduced costs 50 and spent only a quarter of the time to do it Set up Is as easy as 1 2 3 Don t spend valuable time figuring out wiring IDEC SmartRelays require minimal wiring mount on a DIN rail with a quick snap and make programming as simple as the touch of a button All IDEC SmartRelays meet industry standard approvals including cULus CE C tick and ABS American Bureau of Shipping Plus they are FM approved for Class 1 Div 2 hazardous locations It s safe to say we all want to work smarter not harder while also saving money With IDEC SmartRelays it s easy These all in one controllers are easy to use and require less space in your control cabinet which is basically money in your pocket Combine that with low maintenance and you ve got a cost effective product you can count on for all your control operations Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr
12. ts 0 10V DC and 4 20mA input Phone 800 894 0412 Fax FL1D K2B2 e 2 pt analog output module e Generates 0 10V DC output 888 723 4773 Web www clrwtr com Email info clrwtr com Phone 800 894 0412 Lon Builder Neuron 3120 3150 and Echelon are registered trademarks of Echelon USA FL1B CL1012 LONWORKS Communication Module fa LonMark LonWorks LON ty Contre Watve 3 iotrusion Cecio Livia lee wot This communication module is an interface for connecting your IDEC SmartRelay to a Local Operating Network LON The LonWorks communication module is a bus station on the LON and allows the IDEC SmartRelay to communicate with other LON devices Actuator Sensor Interface AS Interface Module FL1B CAS2 itt Osea a Open Network i CC Link DeviceNet MicroS mart AS Interface Master Module Sr i x PS2R eS AS Interface SX5A onitor AS Interface Light Curtain Communication Module Communication Terminal Value lt L S U Sensor AS Interface 4 Light Tower I SX5A_IP67 PN Direct Connection Type EC Communication Terminal A DI Yr g Sensor ml ae ae is iia Sua no op Switc HW eL6eMCM Series P SwitchNet Control Units e a AS Interface Direct Connection Type AS Interface Safety at work Primarily for control of sensors and actuators at distances of up to 100 meters this interface utilizes the simple