WinPAC-8000 User Manual (Standard series solution)

image

Contents

1. um Industrial Control Products On Data Acquisition System Batteryl OK Task Bar Setting Auto Hide Always On Top Battery2 Empty Desktop Change HTTP document root directory Swindows vwwww wwwnpub to Sew inicio e sn nv LIB m Configure the synchronization with a time server The tab use to How to use Adjust the size of the desktop select a display resolution from the Resolution list Lock or Auto Hide the taskbar Auto Hide Select the Auto Hide check box Lock select the Always On Top check box Check the status of the battery See the Battery1 and Battery2 field that displays the battery status Change the HTTP directory path Enter a new path in the Change HTTP document root directory windows www wwwpub to field and then press the Setting button WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 70 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Ethernet Setting Tab The Ethernet Setting tab provides functions to configure either DHCP Roaming or manually configured Static network settings and to monitor the MAC address Generally DHCP is the default settings but if you don t have a DHCP server you must configure the network settings by using manual configuration WinPAC Utility 2 0 2 1 ile Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution Multi
2. Check the OS version BRP Double click the button WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 90 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 Insert the using WinPACNet into the header area after using System Windows Forms Fusing System using System Collections Generic using System ComponentHodel using System Data using System Drawing using System Text using System Windows Forms namespace suysteminfo i public partial class Fo i muam A Tips amp Warnings AN The WinPacNet of unsing WinPacNet is case sensitive Step 6 Insert the following code in the Editor Window MessageBox Show WinPAC pac_GetOSVersion Namespace syusteminfo i public partial class Formi Form 1 public Formi i Initializetomponent H private void buttoni_Click object sender EventArgs e WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 91 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 4 4 Execute the application on the WinPAC Step 1 On the Build menu click the Build Solution command File Edit View Project Debug Data Format Tools Test Window Build Solution ChhShfHB Rebuild Solution Deploy
3. 4 ________ 2500 DBS7x _ E The table below shows the expansion RS 232 RS 422 RS 485 communication modules that are compatible with the WinPAC I 8142iW 2500 Vrms Terminator block x 1 I 81441W 2500 Vrms Terminator block x 1 The WinPAC can be expanded to support up to 16 COM ports For more detailed information about these support modules please refer to http www icpdas com products Remote lIO i 8ke selection rs232 i8k htm WinPAG Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution En Slot D x Driver enabled Slot 1 e Driver disabled Slot 2 Slot 3 8144 Install driver apply to 1 8112 8114 8142 8144 series modules USE SERE USE Step2 Go to File gt Save and Reboot to enable driver Slot scan Refresh WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 77 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com System Memory Setting Tab The System Memory Setting tab provides functions to adjust and monitor the unused RAM WinPAC Utility 2 0 2 1 m m File Help Configuration Auto Execution Multi serial port wizard System Memory Setting Backplane Compatibility EIn Move slider to the left for more memory to run programs Move slider to the right for more storage room Only unuse
4. WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 22 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 4 Overview The WinPAC contains several interfaces and peripherals that can be integrated with external systems Here is an overview of the components and its descriptions The details of these items are as follows WP 8431 WP 8441 WinPAC User 8000 Manual version 2 0 5 Copyright 2009 ICP DAS Co Ltd All Rights Reserved IB LED Indicators B Rotary zin IL 9 Micro SD Socket Sac VGA Port i E USB Port EB Ethernet Port E anns EB Expansion Slot 1 9 44 ee gt L orti 8 Connector BB LED Indicators B Rotary Sito 53 Micro SD Socket Q vaa Port seesee 282222360 ES 0 Expansion Slot F m Lipe J USB Port Ethernet Port s 8 Connector Last Revised February 2011 23 E mail service icpdas com WP 8431 WP 8831 Rotary Switch LED indicators Micro SD Socket n Port A cow com D DIP Switch 9 USB Port Expansion Slot WP 8441 4 Slots Ethernet Port WP 8841 8 Slots B Connector Redundant Power 10 30 Voc
5. PAC IO API Folder Demo Explanation 7 which plugged in the WinPAC Hu This demo program is used by 8K series DI modules Shows how to write the DO values to DO module do F This demo program is used by 8K series DO modules WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 120 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Folder Explanation Shows how to read the DI and the DO values of the DIO module This demo program is used by 8K series DIO modules Shows how to send receive a command response 87k basic application This demo program is used by 87K series modules Shows how use API and the IO modules located 8 K demo as slots This demo program is used by 87K series modules 8k dio 87k ai Shows how to read the values of Al module This demo program is used by 87K series modules Shows how to write the AO values to AO module 07k ao This demo program is used by 87K series AO modules 87k di Shows how to read the DI values of DI module This demo program is used by 87K series DI modules Shows how to write the DO values to DO module 87k_do This demo program is used by 87K series DO modules Shows how to read the and the DO values of the DIO module 87k dio This demo program is used by 87K series DIO modules Shows how to send receive a command response
6. 21 Windows CE 50 jS Empty Project Ef Console Application My Templates H Other Languages Other Project Types Onlme Templates A project for creating Framework 2 0 forms application for Windows CE 5 0 and later Hame Location i Ti Slatin Crete directory for solution Slaton Name Step 4 Click OK to start creating a systeminfo project WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 87 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 4 2 Add project reference for an application Step 1 On the Solution Explorer window right click the Reference and then click the Add Reference command Solution Explorer Solution X ad solution svstemimtfa 1 project GGA systeminfo Properties References ae a Forml cs Add Reference CE Program cs Add Web Reference 33 Class View os solution Explorer The winpacnet dll file can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 SDK WinPacNet http ftp icpdas com pub cd winpac napdos wp 8x3x ce50 sdk winpacnet gt For WP 8x3x series CD Napdos wp 8x4x_ce50 SDK WinPacNet http ftp icodas com pub cd winpac napdos wp 8x4x_ce50 sdk winpacnet Step 2 In the Add Reference dialog box select the Browse tab and then specify the directory of the lt Winpa
7. iu acetate tiia tain oe ode ERE RI FORE 150 D 4 Random 485 Network 152 D 5 Master Slaves SEWN 153 5 1 WinPAC as a Master deraulb s gu I Eds 154 5 2 WIDE AG aS d Od VO 156 Appendix E Tips How to 158 E 1 How to set a telnet and FTP account to login WinPAC 159 Add a telnet ana FTT accoun sudo Cote otia iue 160 1 2 Remove a telnet and FTP account 161 E 1 3 Use Telnet to login WinPAC from PO vi o8 Udvkv d Uo Udvb 162 E 2 Howto online debug 164 E 2 1 Debug WinPAC programs in 164 2 2 Debug WinPAC programs in Visual Studio 2005 2008 174 How to recompile WinCon 182 E 3 1 Compiler old programs which on Wincon 8x3x and 8x4x 183 E 3 2 Modify vcp file to upgrade the old WinCon project 187 Ed FIOW Ine DIMOT u5000020220522102308980093 08030 03 9080 23 089 2UEO HEU 188 4 1 How to use network DFIMer uscisesa vasa cut 189 E 4 2 How to use prin
8. 2 Type cmd Type the Internet rez o Windows Update Programs J Search Help anc Windows Professional Step 3 Type telnet IP address to connect to WinPAC c CAWINDOWS RIDES Aicrosoft Windows AF Yersion 5 1 26808 Copyright 1985 2081 Microsoft Corp C Documents and Settings Administrator te lnet 1 1 1 61 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 162 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 Type user name and password to login CWIMNDOWSAYS vystem 32cmd exe 1 to the Windows CE Debug Service on WaindowsCE login Anna Step 5 The connection has been established a C WINDOWS System3 7 comd exe Welcome to the Windows CE Debug Service on WindowstE login Anna Password gt Pocket CHD v 5 8 Tips amp Warnings If you can t login please check that the FTP setting is enabled WinPAC Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution Multi serial Disable Allow Anonymous C Enable 9 Disable Upload Change FTP default download directory to WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 163 Copyright 2009 ICP DAS Co Ltd All Rights Reserved
9. 4 3 Understanding the WinPAC SDK The WinPAC SDK includes several application programming interfaces APIs that allows you perform various supporting tasks when developing WinPAC Requirements The WinPAC SDK only supports NET Framework 2 0 or above Installation Path After installing the WinPAC SDKs a number of functions can be installed on the Host PC and this installation puts the header files libraries into the following public places so they are easily changed by update the WinPAC SDKs Header files C Program Files Windows Toolswce500 PAC270McpdasMnclude ARMVAT Libraries C Program Files Windows CE Tools wce500 PAC270 Icpdas Lib ARMV41 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 82 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 3 1 WinPAC SDK Overview System Information Watchdog Backplane Access UART J Interrupt Registry Memory Access Micro SD System Operation Remote Local WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 83 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com e Systemlnformation Functions Provides reference information for the system status e Backplane Access API Provides reference information for the backplane access APIs including backplane information e Interrupt API Provides referenc
10. ange 9 afa domui nm ar trant aom tn d E m Always Change HTTP document rook directory Ea WINGO Ss venen Venen DUD m Setting Setting WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 139 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 9 Click Yes to reboot the WinPAC Warning 1 D Would you like to save the setting and reboot the device Step 10 Check the WinPAC OS version otart the WinPAC Utility and then select the System Information tab to check the current OS version WinPAC 1 6 3 9 Check the OS version WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 140 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 2 SDKs Updates The updates files of SDK are located on gt For WP 8x9x series CD Napdos wp 8x3x_ce50 SDK gt For WP 8x4x series CD Napdos wp 8x4x_ce50 SDK Wp 8x3x ce50 wp 8x4x ce50 IO Modules Modbus _ 5 WinconSDK WinPacNet WinpacSDK By eVC and donet development tools the WinPAC SDK installation is divided into the following two parts i WinPAC SDK updates for dotnet li WinPAC SDK updates for eMbedded Visual C WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 141 Copyright 2009 ICP DAS
11. Program Files Folder v Transport Bootstrapper me Startup Provider v Configure Step 10 On the Options dialog click the OK button LB d ES show devices for platform Find and Replace Fonts and Colors PACZTD aa l Help Devices Import and Export settings Intemational Settings Web Browser Projects and Solutions pourre Control Text Editor Database Tools Debugging Default device PACSOU ARMY4 amp EMVAI Release v WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 178 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 11 On the WinPAC run the CommanClient2 and the CMAccept exe applications which is located at System Disk CPDAS System Address System_Disk ICPDAS System TcepCanne eDbgTL CMAccept clientshut AutaLoader winpacsDK Sleep onManz D 428050 24 WinconsDk WwIMPAC PACSl 2Z P pace01 H WAR TCE 000 Wincor dlece400d 00 4009 MFCCE400 Step 12 On the Tools menu click Connect to Device command File Edit View Project Build Debug Data Tools Window Communitv Help Ek Attach to Process Ct Alt Connect to Database Connect to server Lej Code Snippets Manager Choose To
12. Step 7 On the next page of the wizard leave all the options as they are and then click the Next button to the next step WCE MFC AppWizard exe Step 3 of 4 File Edit iew Insert Build Help Would you like to generate source file comments ff TODO C No thank you ff TODO How would you like to use the MFC library As a shared DLL As a statically linked library Finish Step 8 On the next page of the wizard leave all the options as they are and then click the Finish button to complete the wizard WCE MFC App Wizard exe Step 4 of 4 AppWizard creates the following classes for CSDKinfoApg CSDKinfaDlg Class name Header file CSDKinfoApp SDKintoApp h Base class Implementation file cwinapp SDKinfoApp cpp lt Back Next gt Cancel WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 105 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 9 The final summary appears click the button to exit the wizard Hew Project Information VICE MFC App izard exe will create a new skeleton project with the following specifications Application type of SDKinfo Dialog Based Application targeting Win32 CE ARMY 4I Win32 CE Win32 CE MIPSII FP Win32 CE MIPSIV Win32 CE MIPSIV Win32 CE SHA Win32 CE emulator Win32 WCE x86 Classes to be created Applicatio
13. _ 5 RegistryEditor RegistryViewer Remote_display_application SendToCOM TaskMgr VCEP WInPAC Utility WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 56 E mail service icpdas com Copyright 2009 ICP DAS Co Ltd All Rights Reserved e Backup Utility The Backup Utility is a system backup restore tool used to backup restore all the data OS settings and files from to the WinPAC ViewPAC device For more information about the Backup Utility please refer to 3 6 Bacup Utility eDcomcnfg dcomcnfg exe for Windows CE to configure your DCOM settings NTLMUsSer exe for Windows CE to create local NTLM accounts on the Windows CE Device e DCON CE With Host PC running the DCON Utility on the WinPAC the DCON CE program allows user to view and monitor the status of the DCON Utility e ISQLW35 ISQLW35 implements SQL server compact 3 5 Query Analyzer e Modbus The Modbus provides various applications of Modbus protocol for configuring the WinPAC e NAPOPC CE5 NAPOPC CES5 is an integrated omnibus software package it allows user to quickly establish a DCS control system For more information about the NAPOPC_CE5 please refer to 3 2 NAPOPC WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 57 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com e RegistryEditor The RegistryEdit
14. Hetrieves information about the OS version CPU version SDK version gt For WP 8x3x series CD iie Ata d 8x3x_ce50 Demo WinPAC eVCT Standard ndard gt For WP 8x4x series CD Napdos wp 8x4x_ce50 Demo WinPAC eVC Standard fto ftp icodas com pub cd winpac napdos wp 8x4x ce50 demo winpac evc sta ndard WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 124 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 2 2 eVC Demo programs for IO The table below describes the WinPAC demos that have been designed to demonstrate the expansion I O module features of the WinPAC Local PAC IO API Folder Demo Explanation 7 which plugged in the WinPAC Hu This demo program is used by 8K series DI modules Shows how to write the DO values to DO module do F This demo program is used by 8K series DO modules WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 125 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Folder Explanation Shows how to read the DI and the DO values of the DIO module This demo program is used by 8K series DIO modules Shows how to send receive a command response 87k basic application This demo program is used by 87K series modules Shows how use API and the IO modules located 8 K demo as slots This
15. Step 6 The Manual Server Action dialog will appear displaying command line before click the OK button to close dialog turn to the WinPAC controller side to do the next two steps Manual Server Action Please make sure the following files are the device S tepipe dil wWVINHDUW S Seemgre exe WIND OV dil And launch CEMGACLEXE with the following cmd line CEMGAC EXE 5 rT TTEFIPCLDLL 24 0 10 0 9 52 5000 Cancel Step 7 On the WinPAC select the Start menu and then click the command 1 Programs e Favorites L3 Documents GF Settings Bun WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 167 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 8 On the Run dialog type the command which displays in step 6 and then click the button Eo My Device WINPAC Type the name of a AS acumen tiene er oe Ur gi ic myo wv t it for you 2 29 Ce Internet Microsoft Explorer gt tcpipc dll d 10 0 9 52 500d v My Documents Step 9 Return to the Host PC side on the Manual Server Action dialog click the OK button Manual Server Achon Please make sure the following files are on the device WINDOWS Ste pipe dll WIND WS Scemarc exe WIND UV S Sestlstub
16. WinCon 32 2 GENNI Solare E 38 2 1 Mounting BUR amo IRR TQ 38 2 2 Inserting I O 99 1 P 40 the BOOLMOGG EN ETT T T TT 43 2 4 Using WinPAC Utility to manage the WinPAC 47 2 5 Using Utility to Configure Modules sees 48 2 6 Changing the User Interface Language 50 2 4 Installing the Touch Panel Driver 52 2 8 Using Backup Utility to back up the settings and files 5 2 9 A caution about using _ 5 55 ONEPOCHHNILI CHM S 96 59 60 61 oM eig 62 35 WinPAC S 63 64 69 4 Your First WInPAC Program 1 c csccsssscssecsssennsencssennenssnsensenes 80 4 1 Preparing the Development RED MERE EE 80 4 2 Installing WinPAC DIS 81 24 3 naerstanadaiig th SDK eund aieo aie pectet iod eee ouv 82 d 9 WIDPAG SDK OVelVIBW sss nu b HMM MINH 83 AS VWVINPAG SDK ISI er e Leid 85 4A Your First Progra Gr acu acus deco daemon u
17. application This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the values of Al module 7k87k ai This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to write the AO values to AO module 7k87k ao This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the DI values of DI module 7k87k di This demo program is used by 7K or 87K series Al modules which connected through a COM port WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 121 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Folder Demo Explanation Shows how to write the DO values to DO module 7k87k_do This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the DI and the DO values of the DI le 7k87k dio M This demo program is used by 7K or 87K series Al modules which connected through a COM port For application these demo programs can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 Demo WinPAC DotNET C NET PAC_IO fto ftp icodas com pub cd winpac napdos wp 8x3x_ ce50 demo winpac dotnet c9623 net pac io gt For WP 8x4x series CD Napdos wp 8x4x_ce50 Demo WinPAC DotNE IO ftp ftp icodas com pub cd w
18. service help zzervice name gt get information on what servi are supported zzervice service s name in the registry 1 service instance gt particular instantiation ii lt file name gt s silent d output to debugger WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 194 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix F Revision History Revision Date Description 1 0 July 2008 Initial issue 1 1 August 2008 Added more information about WinPAC Utility functions in section 3 5 August 2008 1 Added additional information on how to establish a new telnet and FTP in Appendix E 2 Added additional information on how to use services tool in Appendix E August 2008 Added additional information on how to use network printer in Appendix E Added additional information on how to use printer via USB in Appendix E September 2008 Added additional information on how to automatically update the WinPAC 8000 SDK in Appendix E Added additional information on how to manually update the WinPAC 8000 SDK in Appendix E 3 Added additional information on how to update the WinPAC 8000 OS image from file 1 5 September 2008 Deleted WP 8041 information July 2009 1 Changed the name of the version of this manual 2 Moved the OS and SDK updates from the Appendix E to the Chapter 6 Added information about the multilingual interface chan
19. HRDO AHR LAT ger dut re A p eriz E Table of Contents 4 KI Preface a Overview of the WinPacspls m vv System Information Functions able onten E Preface Overview of the WinPacSDk El 1 System Information Functions 1 1 pac_GetModuleName 1 2 pac etRatarvID Kl 1 3 pac EnableLED 1 4 pac GetSerialMumber Il 1 5 pac GettPLersion il 1 6 pac GetoS Version 1 7 pac GetEbontversion IK 1 8 pac GetSDk Vversian Il 1 9 pac GetMacAddress 110 pac_ChangeSlot 1 11 pac Reboot 1 12 D um 1 1 pac_GetModuleName l 2 pac GetREntarvID 1 3 pac EnableLED 1 4 pac GetSerialNumber 1 5 pac Get Persian 1 6 pac GetoSVersian 1 7 pac GetEbootversion 1 8 pac GetSDk Vversian 1 9 pac_GetMacAddress 1 10 pac ChangeSlnt pac BackwardCampatible LLL pac Reboot E 1 13 pac_GetComMapping 1 12 2 Backplane Access API pac Backwardcompatible 3 Interrupt 4 Memory Access API 5 watchdog Functions 2 Backplane Access MicroSD Management DE d HHE 3 Interrupt UART API 4 Memory Access e E 5 watchdog Functions MicroSD Management 7 Registry API UART PAC IO uem uem uem uem nom uem uen um 1 13
20. July 2010 Modified information about the companion CD in section 1 5 Modified information about using Backup Utility to back up the settings and files in section 2 8 Added information about WinPAC tools in chapter 3 November 2010 Added information about a caution about using System_Disk in section 2 9 Added information about the FTP setting function of the WinPAC Utility in section 3 5 2 and E 1 February 2011 Modified information about the WinPAC overview in section 1 4 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 196 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com
21. 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 9 2 Property Tabs The WinPAC Utility includes the following property tabs all property tabs will be explained later WinPAC Utility 2 0 2 1 m Ethernet Setting Network Setting System Information Auto Execution Multi serial 4 gt Welcome to use WinPAC Utility This tool will help vou to set WinPAC 8000 Display Resolution 600 WinPAC Industrial Control Products S Data Acquisition System Battery OK Task Bar Setting Auto Hide Always On Change HTTP document root directory Swindows www wwwnpub to Nw inii e wn nw wp ub Configure synchronization with a time server Y System Setting Y Ethernet Setting Y Network Setting Y System Information Y Auto Execution Y Multi serial port wizard v System Memory Setting Backplane Compatibility WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 69 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com System Setting Tab The System Setting tab provides functions to configure the task bar HTTP directory path WinPAC Utility 2 0 2 1 File Help Configuration Ethernet Setting Network Setting System Information Auto Execution Multi serial 4 gt Welcome to use WinPAC Utility This tool will help you to set wWinPAC 8000 Display Resolution 600 _
22. Step 16 On the dialog type the command which displays in step 5 and then click the OK button My Device WINPAC ir mum n mam may ya me the name a program a d or document and Windows will open W s it for you z Open Internet Microsoft Explorer tcpipc dl d 10 0 9 52 5000 Bowse ok My Documents Step 17 Return to the Host PC side on the Manual Server Action dialog click the OK button Manual Server Acton Please make sure the following files on the device WINDOWS Stepipe dii SWAB DO S WAS dll And launch CEMGAC EXE with the following cmd line CEMGRC EXE fo 20 10 0 3 52 5000 Cancel WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 172 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 18 On the Manual Server Action dialog click the button Microsoft eM bedded C CA ARMY 4lHelthemory exe does not contain debugging information Press OK to continue Do not prompt in the future Cancel Step 19 Connection established Then you can debug on line Tips amp Warnings If you want to quit the debugger and return to editing you can click AN the St
23. Step 2 On the File menu select the New command and then click the Project command Edit View Project Build Debug Data Toole Test Window Help New ia Project Ctr Shaft N Open Fig Web Site Shiftr Add File t lose Project From Exiting Code Close Solution save AI Export Template Recent Files Recent Projects Exit WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 94 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 In the New Project dialog box do the following in this order Hew Project Project types Templates E Visual Windows p Smart Device Library Wi Console Application My Templates Smart Device i Pocket PC 2003 H Search Online Templates lae E Windows CE 5 0 A project for cred rues amewark 2 0 forms application for Windows CE 5 0 and later ame Location CA mdesws CE Tools B net Ww Schon ZI Creste directory for solution Solution Step 4 Click OK to start creating a systeminfo project WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 95 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 5 2 Add project reference for an application Step 1 On the Class View window right click the Reference and then click
24. The WinPAC provides the Touch Panel driver for PenMount Egalax and ELO touch panels and which can be obtained from WinPAC System_Disk External_ device driven The table below provides a list of supported models and respective device driver names ADP 1080T U penmount usb touch vyyyymmad cab ADP 1080T R penmount serial touch vyyyymmdd cab GA 700YY USB egalax_usb_touch_vyyyymmdd cab GA 700YY UOM egalax serial touch vyyyymmdd cab ELO USB touch panel elo usb touch vyyyymmad cab ELO RS 232 touch panel elo serial touch vyyyymmdd cab For more information on how to make setting of touch panel driver please refer to http www icpdas com products PAC winpac download winpac 8000 download os im ages htm WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 52 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 8 Using Backup Utility to back up the settings and files After saving the configuration settings for a WinPAC device following the first use it is recommended to use the Backup utility to back up all the data settings and files Step 1 Run the Backup Utility on the WinPAC The DCON firmware is located at System_Disk tools Backup_utility backup u Run the Backup Utility Backup Utility Eboot and OS EEPROM Registry SRAM SIZK Svstem Disk Backup information BackupTime 7 a 2010 12 08 28 PM Language English Step 3 Selec
25. WinconSDK WinPacNet WinpacSDK WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 128 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 1 OS updates The updates files of OS image are located on gt For WP 8x3x series CDANapdosWwp 8x3x ce50 OS Image gt For WP 8x4x series CD ANapdosWwp 8x4x 50 05 Image Wapdos Wp 8x3x ce50 wp 8x4x ce50 2101010 update from Eshell update from file There are two ways to update the OS 1 Update from file Please refer to section 6 1 1 We recommend that you use this one for more quicker and easier to update 2 Update from Eshell Please refer to section 6 1 2 Bi Update_from_files Update_from_eshell m pg Upgrad WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 129 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com The WinPAC OS supports multi language 1 en English 2 sc Simplified Chinese 3 tc Traditional Chinese os image update from file update from eshell WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 130 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 1 1 WinPAC OS updates using installation package file on WinPAC Installation package is easier to upgrade OS image you just copy the pac
26. command File Edit View Project Build Debug Data Tools Test Window Help ied M M 7 Attach to Process v PACSO ARMY4 AEMVAI Release al j as Device security Manager Mz create database Forml cs Desig Ba Connectto Device a __ if Device Emulator Manager E Application _ 1 Connect to Database zw Configuration Eni Connect to Server sis Un tms gj Code Snippets Manager Ctr B Build Event Target device Choose Toolbox Items Debug SO ARMY 4 Add in Manager Autput file folder Macros Resources G4 SIDL PROGRAM FILI Reference Paths Deploy the latest version Create GUID Signing thenticode signing Dotfuscator Community Edition Sign the projectoutputw Eds WCF Service Configuration Editor Devices Extemal Tools select Cer Import and Export Settings Customize Options E Step 6 On the Options dialog select 270 from the Show devices platform list and then click the Properties button si x Find and Replace Fonts and Colors ibd Devices Import settings D alana International cetti I E EI 1 4 ARM 1 AT Release Web Browser Delete Projects and Solutions 8 8 Control Text Editor Database Tools D
27. dii And launch with the following cmd line 5 rFTCPFIPEDLL 0 10 0 3 52 5000 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 168 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 10 On the Testing Device Connection dialog click the OK button Testing Device Connection Device Name ACTU Device Connection to device established TLPAP Transport for Windows CE Step 11 On the Device Properties dialog click the OK button Device Properties Device Name PACZT Device select a transport and a startup server Choose Test to verify that wou can establish a connection to your target device with the selected transport and startup server Transport Transport for Windows CE configure startup server Manual Server Cancel Test WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 169 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 12 On the Windows CE platform or device to configure dialog click the OK button Windows CE Platform Manager Configuration select platform or device to configure Add Device Delete Sy PAC270 Device m STANDARDSDK 420 Windows CE Default Platform use About Step 13 On the Build
28. pac_GetlomMapping 1 miii niu WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 85 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 4 Your First Program in CZ Here we will explain how to create a C program running on WinPAC We assume that you use Visual Studio 2005 Depending on the version of To create a demo program with development tool includes the following main steps 1 Create a new project 2 Add project reference for an application 3 Design and Build an application program 4 Execute the application on the WinPAC All main steps will be described in the following subsection 4 4 1 Create a new project Step 1 Start the Visual Studio 2005 Step 2 On the File menu select the New command and then click the Project command File Edit View Project Build Debug Tools Test Window New g ChbBhfHN Open Web Site Shiftr Alt Add Hk CtrleN lose Project From Existing Code Close solution save All Export Template Recent Files Recent Projects Exit e 86 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 In the New Project dialog box do the following in this order Hew Project Project types Templates E Visual C D Windows Smart Device 58 Class Library 0 Pocket PC 2003
29. 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 3 Star Type RS 485 Network There are branches along the main network In this case it is better to have a repeater to isolate or filter the noise that is made by devices 232 485 Converter 7520 Series 485 Repeater 7510 Series 485 Repeater 7510 Series 485 Repeater 7510 Series WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 150 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com There is a better choice to use 7513 as a RS 485 hub on start type network 232 485 Converter 7520 Series 485 Hub 7513 Series WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 151 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 4 Random RS 485 Network There are branches along the main wire In this case it is better to have a repeater to isolate or filter the noise that is made by devices 232 485 Converter 485 Repeater 7520 Series me 7510 Series 485 Repeater 7510 Series WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 152 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 5 Master Slaves Settings The RS 485 network based on master slave architecture consists of a single master device and one or mor
30. 232 485 ports two Ethernet ports to connect serial I O and Ethernet I O And with FRnet and CAN communication module in local slot FRnet I O and CAN devices are easy to be integrated WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 11 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Built In Flash Disk 31 63 MB In normal situation users can store their AP or data to the Micro SD card or USB Flash disk But in some vibrational environment for example like driving ships the two storage media would be bad connection Then the built in Flash disk will be the best storage media in such the vibrational environment Dual Watchdog Timer A system could be hanged up when the OS or the AP fails There are two watchdogs OS watchdog and AP watchdog designed to automatically reset the CPU when the situations happen The design will increase the reliability of the system Dual Battery Backup SRAM 512 KB To maintain important data while power off non volatile memory is the ideal design The WinPAC 8000 equips a 512 KB SRAM with two Li batteries to maintain data while power off The two Li batteries can continually supply power to the 512 KB SRAM to retain the data for 5 years and the dual battery design can avoid data lost while replacing a new battery Dual Ethernet Ports WinPAC 8000 provides two Ethernet ports The two Ethernet ports can be used to implement r
31. All Rights Reserved E mail service icpdas com COM3 RS 232 RS 485 Operating Modes Selector COM4 RS 232 Power Indicator Micor SD socket Alin OIL S232 DIP Switch 8 Slots Analog Input Out Digital Input Output Motion Timer Counter Redundant Power 10 30 Voc Ethernet Port 2 Relay Output COM2 RS 485 Frame Ground ER R USB Port 1 i B Ethernet Port 1 am P WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 33 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com W 8x3x Phased Out Since 2008 W 8x3x is a equipped with PC interface and 3 7 slots for modules Its PC like interface includes PS 2 keyboard and mouse port USB port and 232 485 communication ports The powerful backplane 3 7 slots can adopts versatile ICPDAS s high performance parallel 1 8 modules and serial type modules I 87K modules USE 7 VO Slots Digital uu 5 Digital InputChutput Keyboard Motion TimarCountar Mouse MCU RS 232 Power a 10 30VDC R amp 485 LED Indicator a ES 10 Base T Compact Flash 1 VGA WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 34 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com W 8x4x WinCon 8x4x series embedded
32. Co Ltd All Rights Reserved E mail service icpdas com 6 2 1 WinPAC SDK updates for C or VB net To determine the SDK version that is compatibly running on the WinPAC you can read the Release Note which is located under each SDK folder these files provides important updated information for what we fixed and added Step 1 Get the latest version of the C or VB net components The latest version of the C or VB net components can be obtained from gt For WP 8x3x series http ftp icpdas com pub cd winpac napdos wp 8x3x ce50 sdk winpacnet gt For WP 8x4x series http ftp icodas com pub cd winpac napdos wp 8x4x_ce50 sdk winpacnet Step 2 Copy the latest version of DLL to Host PC and WinPAC The DLL files on Host PC are located at anywhere only the solution can reference it The DLL files on WinPAC are located at the same directory as the exe file WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 142 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 2 2 WinPAC SDK updates for eMbedded Visual To determine the SDK version that is compatibly running on the WinPAC you can read the Release Note which is located under each SDK folder these files provides important updated information for what we fixed and added Step 1 Get the latest version of the eMbedded Visual components The latest version of the eMbedded Visual components ca
33. DCON protocol RS 485 WinPAC 8000 is equipped with two RS485 COM ports which enable the transmission rate up to a maximum of 115 2 Kops The medium for connection is a twisted pair multi drop 2 wire RS 485 network that can link i 7000 M 7000 RU 87Pn and high profile 87K modules FRnet FRnet is an innovative industrial field bus that has many special features such as high speed deterministic I O control real synchronization capabilities non protocol communication and easy programming Plugging in an FRnet communication module 1 81 72W the WinPAC 8000 can link FRnet modules to implement high speed distributed CAN Bus The Controller Area Network CAN is a serial communication way which efficiently supports distributed real time control with a very high level of security It provides the error processing mechanisms and concepts of message priority These features can improve the network reliability and transmission efficiency Furthermore CAN supplies the multi master capabilities and is especially suited for networking intelligent devices as well as sensors and actuators within a system or a sub system With 1 8120 l 8123 8124 I 87120 1 87123 and 1 87124 WinPAC 8000 is able to demonstrate every feature of CAN CANopen and DeviceNet WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 14 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service i
34. HEC COL OVA IREAD 4 Step 9 On the Project menu click Settings command Ede Edit Yiew Insert Project Build Tools Window Help set Active Project Add To Project Dependencies Export Makefile Insert Project into Workspace Step 10 On the Project Settings dialog select the Link tab and change the value of the Project Options field ARM to THUMB and then built the project Project Settings Settings General Debug C C Link Resources M nn win32 CE ARMYAI Release erae Genera Beset enera T HESE Project Option sgo o R WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 186 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 3 2 Modify vcp file to upgrade the old WinCon project Step 1 Open a text editor to modify the vcp file Step 2 In the vcp file replace 0xa301 with 0 501 Step 3 In the vcp file replace ARMV4 with ARMVAI Step 4 In the vcp file replace MACHINE ARM with MACHINE THUMB Step 5 Save the vcp file just edited Step 6 Open the old WinCon project and recompile it WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 187 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 How to use the printer WinPAC have ability to acce
35. Plug will be available supports high profile 87 modules only I O Module Hot Swap Ability WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 18 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com WP 8131 WP 8141 95x 132x 111 mm WP 8431 WP 8441 230 x 132 x 111 mm WP 8831 WP 8841 354 x 132x 111 mm Operating Environment Operating Temperature 25 C 75 Storage Temperature 30 80 Humidity 10 90 Non condensing WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 19 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 3 Dimensions There are several series of WinPAC modules whose overviews depended on the quantity of the slot All dimensions in millimeter Front View EE a 122 0 132 0 111 0 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 20 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Top View 122 0 132 0 Front View WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 21 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Top View 122 0 1320 E D O 1 ee ME ssl i E WW OB HH Eg
36. R COM Relay Output R NO D JH cowe Frame Ground FG WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 24 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com WP 8441 WP 8841 LED indicators Rotary Switch EB Micro SD Socket Fh d COM4 vca Port S coms com a0 sa es E AP DIP Switch LIEN 1 72 ER E E E In 5 Expansion Slot WP 8441 4 Slots Ethernet Port WP 8841 8 Slots 43 USB Port Gee Connector Redundant Power 10 30 Voc R COM ob Relay Output R NO Da l ob D i Frame Ground WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 25 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 LED Indicators The WinPAC has two LED indicators that are located near the rotary switch and show the operation status LED Indicator State Color Meaning RUN ON Red The OS is ON Blinking The System disk formated ON Green OFF 2 Rotary Switch Tom The Rotary Switch is an operating mode selector switch which provides seven functions related to the selection of the operating mode and authorization control for the WinPAC 2 For more information about the operating mod
37. Step 4 On the WinPAC execute the X EE uploaded file syotemintoa X 01040102 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 116 Check the O5 version 2 ERLED Dialagfeld Steuerelem hier Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 APIs and Demo References This chapter introduces demo programs that have been designed for the WinPAC You can examine the demo source code which includes numerous comments to familiarize yourself with the WinPAC API This will allow developing your own applications quickly by modifying these demo programs The following details the contents of the WinPAC demo programs WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 117 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 1 Demo programs with CZ The following C demos have been designed to demonstrate the various features of the WinPAC 5 1 1 C Demo programs for WinPAC Standard API The table below describes the WinPAC demos that have been designed to demonstrate the standard operation features of the WinPAC system Information Watchdog Backplane Access UART Interrupt Registry Memory Access Micro SD WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 118 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E m
38. and WP 8141 1 0 A 5 V supply to CPU and backplane 0 6 A 5 V supply to I O expansion slots total 30 W WP 8431 and WP 8441 1 1 A 5 V supply to CPU and backplane 4 9 A 5 V supply to I O expansion slots total 30 W WP 8831 and WP 8841 1 2 A 5V supply to CPU and backplane 4 8 A 5 V supply to I O expansion slots total 30 W Consumption WP 8131 and WP 8141 7 3 W 0 3 A 24 V WP 8431 and WP 8441 9 1 W 0 38 A 24 V WP 8831 and WP 8841 9 6 W 0 4 A 24 V amp Communication Ports VGA WP 8x3x Yes with one extra GPU resolution 1024 x 768 800 x 600 640 x 480 WP 8x4x Yes 640 x 480 800 x 600 resolution Ethernet Port RJ 45 x 2 10 100 Base TX Auto negotiating LED indicators USB 1 1 host WP 8x3x 2 WP 8x4x 1 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 16 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com amp Communication Ports COMO Internal RS 485 interface communication with I 87K modules in slots Note CPU internal UART Baud Rate 115200 bps Data Bits 8 Parity None Even Odd Stop Bits 1 FIFO 1 byte RS 232 used to update firmware Note CPU internal UART Baud Hate 115200 57600 38400 19200 9600 4800 2400 1200 bps Data Bits 7 8 Parity None Even Odd Stop Bits 1 FIFO 1 byte COM2 RS 485 Note 160550 compatible Baud Rate 115200 57600 38
39. controllers are derived from existing WinCon 8x3x series This evolution includes dual USB host ports to support more connectivity to USB I O devices dual Ethernet 10 100M ports to provide higher network performance network security and redundancy capability and a rotate switch to configure your system and applications Bus VO Expansion Siot LED indcato COM Port RS232 Port 5485 OS Windows CE 5 0 CPU 520 MHz SDRAM 128 MB Dual Battery 512 KB Backup SRAM Flash 128 MB 64 MB for OS image 63 MB for built in Flash disk 1 MB for registry WinPAC User 8000 Manual version 2 0 5 Windows CE 5 0 Windows CE 4 1 520 MHz 206 MHz 128 MB 64 MB 512 KB Windows CE 4 1 206 MHz 64 MB 96 MB 64 MBfor 32 MB for OS 32 MB for OS OS MB image 31 image only for built in Flash disk 1 MB for registry Last Revised February 2011 Copyright 2009 ICP DAS Co Ltd All Rights Reserved image only Page 35 E mail service icpdas com EEPROM Expansion Memory Slot Interface Ethernet Port COMO COM1 COM2 COM3 COM4 olots 16 KB Micro SD slot Default 1GB USB1 1 x 2 VGA port x 1 1024 x 768 640 x 480 800 x 600 RJ45 x 2 10 100 BaseTX For 1 87 module in I O slot RS 232 RS 485 RS 232 485 RS 232 Expansion 1 4 8 64 bit Hardware Yes Serial Number Push button Programmable LED Dual Timer Watc
40. copy and paste rule users can still finish the upgrading by recompiling the old applications WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 10 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1L mE me Features Power CPU Module The most important features of the CPU module are 1 PXA270 or compatible CPU 32 bit and 520MHz 2 128 MB SDRAM 3 63 MB Built In Flash Disk WP 8x3x 31 MB Built In Flash Disk WP 8x4x Built in Port A built in VGA port can be directly connected to a regular LCD display Users can operate the HMI or SCADA software running on the WinPAC 8000 with display keyboard and mouse just as how they usually did on regular PCs 64 bit Hardware Serial Number The 64 bit hardware serial number is unique and individual Every serial number of WinPAC 8000 is different Users can add a checking mechanism to their AP to prevent software from pirating VO Module Hot Swap Ability The WinPAC 8000 features hot swap which means that there is no need to power off the WinPAC 8000 for replacing modules And the OS provides a function sending plug in and removing P messages to user s applications Using this i feature users can design its own plug and play applications Plug amp Play Rich Expansion Ability RS 232 485 Ethernet FRnet CAN Beside the local I O slots WinPAC 8000 also equips several RS
41. menu select the Start Debug command and then click the Go command Ele Edit View Project Build Tools Window Help 2 Compile systeminfodlgcpp Build SwstemInto exe Rebuild Batch Build lean stat Debug Update Remote Output File s 3 Sten Into Fil Execute Ct ES P Run to Cursor Set Active Configuration Attach to WCE Process configurations oet Active Platform WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 170 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 14 The Manual Server Action dialog will appear displaying a command line before click the OK button to close dialog turn to the WinPAC controller side to do the next two steps Manual Server Action Please make sure the following files are on the device WIND dll wWwINDDWS Seemagrc exe wWwWINDUWS cetlstub dll And launch with the following cmd line CEMGRC EXE ATTCPIPC OLL 4 D 10 0 3 52 2005 Cancel Step 15 On the WinPAC select the Start menu and then click the Run command F Programs gt fz Favorites d 3Documents gt GF Settings b Bun WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 171 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com
42. reliable The following options will provide a better protection for the module The 1 8000 controller has a metallic board attached to the back of the plastic basket as shown in the Figure 2 1 below When mounted to the DIN rail connect the DIN rail to the earth ground because the DIN rail is in contact with the upper frame ground as shown in the Figure 2 2 below Connect to the Earth Ground WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 145 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix B Redundant Power The WinPAC provides two power inputs that can be connected simultaneously to live DC power sources If one of the power inputs fails the other live source acts as a backup to automatically support the WinPAC s power needs The WinPAC provides relay contact outputs to warn technicians on the shop floor when the power fails 24VDC Power Supply Back up Power Supply PWR1 PWR2 Relay Output WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 146 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix C I 8K and l 87K Modules There are 1 4 8 slot options to expand local I O And the I O modules can be parallel bus type high profile I 8K series and serial bus type high profile I 87K series The difference between them is Item l 8K Series 87
43. server WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 63 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 5 1 Menu Bar The WinPAC Utility includes the following function menu All function menu will be explained later File Menu Help Configuration Save Save and Reboot Reboot Without Save Restore Default Settings Exit Y Help Menu File LS Configuration Reset System to Default Release Notes About v Configuration Menu File Help Configuration Import Registry key Export Regsitry key Store All Registry Setting Dump All Registry Setting WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 64 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com File Menu sis Help Configuration Save Save and Reboot Reboot Without Save Restore Default Settings Exit The menu commands Use to Save Saves the settings into Flash The new settings don t take effect until the WinPAC restart Save and Reboot saves the settings into Flash and restart the WinPAC The new settings will take effect after the WinPAC restart Reboot Without Save Restarts the WinPAC without save the settings into Flash Restore Default Settings Restarts the settings of WinPAC to its factory default values The settings include configuration setting network setting auto ex
44. service icpdas com 2 9 A caution about using System Disk The System disk is an authoritative storage device but is not suitable for frequent copying and deleting of files and is only suitable for storing important files that are not changed frequently If files are copied and deleted frequently the system will automatically perform a oystem Disk defragment action which will consume the total resources of the CPU and cause the OS not to function correctly When the OS System Disk defragment action is being performed the run LED will blink and the defragment action icon will show in the system tray in the bottom right hand of the pc screen Note Do not power off the WinPAC while the defragment is being performed Tips amp Warnings Don not power off the WinPAC while the Running Mode defragment is being performed 2 O D w M Ww ICPDAS Took US dete Watchdog gd of LJ Copy 2 of 25 A 9 System Disk Show the icons WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 55 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Tools and Tasks This chapter briefly describes the functions of the WinPAC software toolkits Following tools has been installed on the WinPAC CD Napdos wp 8x3x_ce50 wp 8x4x_ce50 System_Disk Tools Backup Utility Dcomcnfg DCON_CE ISQLW35 Modbus
45. the Reference command Class E Step 2 In the Add Reference dialog box select the Browse tab and then specify the directory of the Winpacnet dll file in the File name field Add Reference Add Web Reference sort Alphabetically sort By Object Type sort By Object Access Group By Object Type The winpacnet dll file can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 SDK WinPacNet http ftp icpdas com pub cd winpac napdos wp 8x3x ce50 sdk winpacnet gt For WP 8x3x series CD Napdos wp 8x4x_ce50 SDK WinPacNet http ftp icodas com pub cd winpac napdos wp 8x4x_ce50 sdk winpacnet Add Reference Projects Browse Recent exe ramets Qm File Name WinPacHet dll File Types Component Files dlL tlb olb ocx exe manifest WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 96 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 5 3 Design and Build an application program Step 1 Buton Adda button object in the From1 dialog box Step 2 Right click the button object and click the Properties command Formi cs Design Start Page Object Browser Form1 E fa x F Judd J n FL AA v n E Q buttoni Im x Prem aere s Bring to Front Send to Back Lock Controls select Forml WinPAC User 8000 Manual version 2
46. the default settings Start the WinPAC Utility and then click the Restore Default Settings command and Save command from the File menu tep 3 Restart the WinPAC in lestie pania normal mode urn the rotary switch to 0 and then restart the WinPAC WinPAC wt Change 79 defaut Geet Cay m ange rm Umm m m e Save Save and Reboot Reboot Without Save Restore Default Settings Exit m m Always Top Change HTTP document root directory En WAI oves ene LID m Setting FTP Setting System gt solution 220 240 Setting WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 44 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Debug mode Debug mode is a special environment in which program debug functions can be used in addition to normal system functions Debug mode is unsupported OS Update mode OS update mode is a way used to update OS To update the WinPAC OS image please refer to 6 1 OS updates DCON CE mode This mode is the same as Normal mode Besides will be run automatically after booting Tips amp Warnings DCON_CE exe must be placed on the V System Disk Tools DCON CE or else CE exe cannot be run automatically after booting VCEP mode This mode is the same as Normal mode Besides VC
47. version 2 0 5 Last Revised February 2011 157 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix E Tips How to WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 158 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 1 How to set up a telnet account to login WinPAC WinPAC Utility has an account management function that controls the user that has access into the telnet and FTP server WinPAC Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution Multi serial gt FTP Setting Users and Password FTP JDisable Allow Anonymous JEnable Disable Allow Anonymous Enable 3 Disable Upload Change FTP default download directory Temp to C WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 159 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 1 1 Add a telnet and FTP account To establish a new telnet and FTP account please perform the following steps Step 1 Run the WinPAC Utility located on desktop tep 2 Select the Network Setting tab and then select the Users and Password tab tempns jorr tmr roma tnr rtm aa temm tamil ewe A vw ueri tep
48. 0 5 Last Revised February 2011 97 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 On the Properties window type Check the OS version in the Text edit box Properties button Syetem Windows Forms Button RightToLeft Check the OS version w Testi lien Middle enter TextlmageRelation Overlay Text The text associated with the control Eg Class View el olution Explorer op Properties Step 4 In the Form1 dialog box double click the button object to open the editor window Check the OS version BRP Double click the button WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 98 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 Insert the following code in the Editor Window 1 Imports WinPacNet 2 MessageBox WinPAC pac GetOSVersion Public Class Formi Private Sub Buttoni Click ByWVal sender As System End Sub End Class Tips amp Warnings A The WinPacNet of Imports WinPacNet is case sensitive WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 99 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 5 4 Execute the ap
49. 18 5 1 2 C Demo programs for PAC 10 120 5 2 Demo Programs with eMbedded Visual 123 5 2 1 Demo programs for WinPAC Standard 123 5 2 2 Demo programs for PAG IO Lassscsasdeuaesudd 125 b WInPAC UDGAIES scien vue EgEENVKIIVENExFNSEEXENI SUECENYURKESENE URS 128 SNO oO 129 6 1 1 WinPAC OS updates using installation package file on WinPAC 131 6 1 2 WinPAC OS updates using Eshell via Ethernet 136 229065 0 141 6 2 1 WinPAC SDK Updates TOF or VBDOL io 142 6 2 2 WinPAC SDK updates for eMbedded Visual 143 7 WinPAC Download Center 144 Appendix A Frame Ground eee 145 Appendix B Redundant Power 146 Appendix C I 8K and 1 87 Modules 147 Appendix D Application of RS 485 Network 148 Basic T19 499 NODWOUIN i debi t EE bene 148 D2 Daisy Chain He 495 NeDWOFK 149 D 3 Star Type RS 485
50. 3 Fill a user account the User name and Password field and then press Add button the user will be added to the user account list WinPAC Utility 2 0 m File Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution J4 WinPAC Utility 2 0 2 1 File Help Configuratior The user wi be t System Setting Ethernet added the user Note FTP Setting Users and account list The accounts is uf User name Password the servers search FTP WebServer Username Password Esther Password d ser name Esther The accounts is used to login the servers search as Telnet FTP WebServer etc on WinPAC Step 4 Press Setting button FTP login If the login succeeds the dialog will display when the user account has been created Login succeeds The users af FTP have been enabled right now WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 160 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 1 2 Remove a telnet and FTP account To remove a telnet and FTP account please perform the following steps Step 1 Run the WinPAC Utility located on desktop tep 2 Select the Network Setting tab nd then select a user account from he user account list The user account hat you select will display in the User name an
51. 400 19200 9600 4800 2400 1200 bps Data Bits 5 6 7 8 Parity None Even Odd Mark Always 1 Space Always 0 otop Bits 1 2 FIFO 16 bytes RS 232 RS 485 for WP 8431 WP 8441 WP 8831 and WP 8841 only Note 16C550 compatible Baud Rate 115200 57600 38400 19200 9600 4800 _ 2400 1200 bps Data Bits 5 6 7 8 Parity None Even Odd Mark Always 1 Space Always 0 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 17 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com amp Communication Ports Stop Bits 1 2 FIFO 16 bytes Tips amp Warnings N COMG can be configured as either RS 232 or 485 that only can select one at a time and Its configuration depends on the pin connections as follows RS 232 RXD TXD CTS RTS and GND RS 485 Data and Data There is no software configuration or hardware jumper needed COM4 RS 232 for WP 8431 WP 8441 WP 8831 and WP 8841 only Note 16C550 compatible Baud Rate 115200 57600 38400 19200 9600 4800 2400 1200 bps DSR Data Bits 5 6 7 8 RTS CTS Parity None Even Odd Mark Always 1 Space Always RI 0 Stop Bits 1 2 FIFO 16 bytes I O Expansion Slots Slot Number supports high profile 8K and 87 modules WP 8131 and WP 8141 1 Slot WP 8431 WP 8441 4 Slots WP8831 WP 8841 8 Slots Hot
52. 5 After completing the above mentioned tasks the Warning dialog box will appear as follow before clicking the button you must first turn the rotary switch to the 0 position Reboot this device right now Please turn the rotary swithc ta 0 normal made WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 134 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 6 Check the WinPAC OS version otart the WinPAC Utility and then select the System Information tab to check the current OS version WinPAC Ufity 1 0 3 9 Check the OS version WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 135 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 1 2 WinPAC OS updates using Eshell via Ethernet Upgrade By default the OS updates via LAN1 Therefore to update the OS image make sure LAN1 is connected to the PC Below is a step by step procedure for updating the WinPAC OS Step 1 Get the latest version of the WinPAC OS image The latest version of the installation package can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 OS_Image update_from_Eshell htto fto icodas com pub cd winpac napdos wp 8x3x ce50 os image update from Eshell For WP 8x4x series CD Napdos wp 8x4x_ce50 OS_Image update_from_Eshell htto fto icodas c
53. E mail service icpdas com 2 How to online debug WinPAC Debugging is a process that you use to find and resolve errors or bugs in a program E 2 1 Debug WinPAC programs in EVC Step 1 On the Tools menu click Configure Platform Manager command File Edit View Insert Project Build Tools Window Enor Lookup Remote Call Profiler WCE500 Remote File Viewer WCE500 Remote Heap Walker WCE500 7 Remote Kemel Tracker WCE500 Remote Performance Monitor WCES5O00 Remote Process Viewer WCE500 Remote Registry Editor WCE500 P gt Remote WCESOQ Ao Remote System Information WCE500 Remote Zoomin WCESOQ select Remote Tools gt Customize Options 9 Macro Record Quick Macro Ctrl Shift R Play Quick Macro Ctrl Shift P Configure Platform Manager WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 164 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 On the Windows CE Platform Manager Configuration dialog click the Properties button Windows CE Platform Manager Configuration select platform or device to configure Add Device EE Delete STANDARDSDK_420 zm Windows CE Default Platform Step 3 On the Device Properties dialog click the Configure button Device Properties Device Name PACZT Device select a t
54. EP exe will be run automatically after booting Tips amp Warnings AN VCEP exe must be placed on the System_Disk Tools VCEP or else VCEP exe cannot be run automatically after booting WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 45 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com User mode Rotary switch position 7 8 9 are reserved for user s applications When WinPAC is boot with one of these rotary switch positions it is boot at normal mode User s application can check the rotary switch position to run at different mode WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 46 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 4 Using WinPAC Utility to manage the WinPAC The WinPAC Utility is a toolkit used to quickly control and configure the WinPAC For more detailed information on WinPAC Utility applications please refer to 3 5 WinPAC Utility Step 1 Run the WinPAC Utility located on desktop tep 2 Configure IP address DHCP FTP Server Auto Execution files etc Ethernet Setting FTP Setting System Batteryl OK Display Resolution 320 240 v Battery Task Bar Setting Auto Hide w Always On Top Change HTTP document raot directory to System Setting setbng Step 3 Save and Reboot the Win
55. LLO exe 5 met Active Confieuratiam ontieuratiomns set Active Flattonm Step 3 Make sure the CPU type is STANDARDSDK fa Demo Microsoft eMbedded Visual DemoDIg cpp Sele E Ede Edit View Insert Project Build Tools Window Demo px TCHAR temp 28 stopstring Demo resources oi VWH m ROB8 GetWindovText temp 28 oat wcstod temp amp stopstring WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 183 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 On the Configurations dialog click the button Lontizuratons Projects and Demo Win32 WCE emulator Release Step 5 On the Project Configuration dialog choose one of the CPU type and then click the OK button Add Project Configuration CPU Wini VICE ARMV 4l Cancel Copy settings from Default Debug Configuration Contiguration Release The new configuration will be called Demo fin32 ARMVAI Release WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 184 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 6 On the Project menu click Settings command E Bile Edit View Insert Project Build Tools Window Help set A
56. LSAC4 TASy Ed Create new workspace C Add to current workspace Dependency of Hello CPUs je Win32 WCE ARMV4 iewWin32 ARMVAI Win32 WCE ARMVAT Win32 WCE MIPS16 ie Win32 WCE MIPSII wWin32 MIPSII FP cancel Tips amp Warnings AN The selected CPU type must have Win32 WCE ARMVAI Step 4 Click the button to start the wizard WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 103 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 On the first page of the wizard select Dialog based option then click the Next button to the next step WCE App Wizard exe Step 1 of 4 What type of application would you like to create c Single document Document View architecture support What language would you like your resources in Step 6 On the next of the wizard leave all the options as they are and then click the Next button to the next step Step 2 of 4 What features would you like to include Windows Help Active Controls Please enter a title for your dialog SDKinfo Help contents file SDKinfo htp lt Back Finish Cancel WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 104 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com
57. Off Punnindg Punnirncdgq Iunnir Step 3 Type the commands to configure service Syntax services stop services name For example turn on the FTP service services stop FTPO File Edit Help Pocket CHD x 65 0 gt 17 services list 000030110 Bunning TPO x g03157 0 HTTPD DLL Bunning x no3z credzswvc dll Bunning 11 000036790 HSH D Dll off 00 66 0 UBERSrVr dll TELNETD D11 zmbserwver dll timezswvco dll ax d s37act SHBU Ox000se3e0 TPO x nn3ttrftr Bunning Bunning Bunning WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 193 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Tips amp Warnings For more information about using services tool you just type services help File Edit Help Packet CMD x 5 0 help print this text list lists loaded services load zerwvice name gt activates a service that is i stop zervice instance gt stops pauses a service doe start instance gt startz rezsumezs a Service refresh zzervice instance gt causes service to refer unload zervice instance gt causes service to be ur register cservice name gt service will be automatic ebhoot unregister Service name gt service will not be aut ext reboot Command Service name gt argl send servi
58. PAC Help Configuration Save d NNI rur Save and Reboot Reboot Without Save eSdlution 20 240 Restore Default Settings Exit E Always on Change HTTP document root directory to WAITS AAA AAA LIB Setting Setting WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 47 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 5 Using DCON Utility to Configure I O Modules DCON Utility is a tool kit used to quickly control and manage 1 87 series expansion modules Step 1 Run the DCON firmware on the WinPAC DCON firmware is located at System_Disk tools DCON_CE Step 2 Run the DCON Utility on the host PC Run the DCON firmware The DCON Utility can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 PC_Tools DCON_ Utility http fto icodas com pub cd winpac napdos wp 8x3x ce50 pc tools dcon utility gt For WP 8x4x series CDANapdosWwp 8x4x ce50 PC Tools DCON Utility http ftp icpdas com pub cd winpac napdos wp 8x4x ce50 pc tools dcon utility Run the Utility Run the WINCE button exer aem Rer Ue Bedae T SEP Fe Won Dua Seem 1 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 48 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 Enter the IP address o
59. Series Microprocessor Yes 8051 Communication interface Serial bus Communication speed Slow Counter input for digital input module Yes 100 Hz Safe value No Yes es Programmable slew rate for AO module WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 147 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix D Application of RS 485 Network The RS 485 length can be up to 4000 ft or 1 2 km over a single set of twisted pair cables if the RS 485 network is over 4000 ft or 1 2Km the RS 485 repeater must be added to extend the RS 485 network D 1 Basic RS 485 Network The basic component of the RS 485 network consist of a Master Controller or using a PC as a host controller and some RS 485 devices it 1 EERE A L LLELELELELELE 232 485 Converter 7520 Series WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 148 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 2 Daisy Chain RS 485 Network All RS 485 devices are wired directly to the main network If the network is up to 1 2 km it will need a repeater 7510 series to extend the network length 232 485 Converter 485 Repeater 485 Repeater 7520 Series Rm 7510 Series meee 7510 Series WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 149 Copyright
60. WinPAC 8000 User Manual Standard series solution Version 2 0 5 February 2011 service and usage information for Model WP 8131 Model WP 8431 Model WP 8831 Model WP 8141 Model WP 8441 Model WP 8841 Written by Sean Hsu Edited by Anna Huang Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year beginning from the date of delivery to the original purchaser Warning ICP DAS assumes no liability for any damage resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements of patents or other rights of third parties resulting from its use Copyright Copyright 2009 by ICP DAS Co Ltd All rights are reserved Trademark The names used for identification only may be registered trademarks of their respective companies Contact US If you have any problem please feel free to contact us You can count on us for quick response Email service icpdas com Table of Contents t UO UG t 7 Spee apr etc pe ene ee 8 CIC 15 1 3 DIMENSIONS QT ENEMIES 20 I MODERNE 23 iro MM 31 1 6 Comparison or WinPAC
61. account account press the Add button and then press the Setting button Delete a user Choose a user name from the user account list the user account account that you select will display in the User name and Password filed press the Delete button and then press the Setting button The maximum number of the user accounts is 5 The maximum of the string length of the user name and password fields must be less than 20 charachters For more information on how to use a user account to login WinPAC please refer to E 1 How to set up a telnet and FTP account to login WinPAC WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 74 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com System Information Tab The System Information tab provides functions to monitor necessary system information of the WinPAC The system information is the most important note of version control for upgrading system WinPAC Utility 20 2 1 File Help Configuration System Setting Ethernet Setting Network Setting Slot 0 Module Slot 1 Flash Type iSystem disk Flash 5 64 bit Serial Number 01 89 81 12 00 00 06 OS Version 1 4 1 2 2009 08 06 10 16 15 Eboot version 1 0 5 8 2008 01 22 15 58 42 Backplane version CPU Version WP 844x 96MB 1 0 2 0 1 0 8 0 WinFacsbk version na c WinPacMet version Framewo
62. ail service icpdas com WinPAC Standard API Folder Demo Explanation O Retrieves information about the DIP switch backplane ID and slot count Shows how to read write date values memory from to EEPROM memoryaccess Shows how to read or write to the battery backup sram battery backup watchdog watchdog Displays how the watchdog operate Shows how to enables disables microsd microsd management Micro SD Shows how to read write date values registry registry from to registry m Shows how to read the name of local I O modules via UART For C application these demo programs can be obtained from Hetrieves information about the OS version CPU version SDK version gt For WP 8x3x series CD Napdos wp 8x3x_ce50 Demo WinPAC DotNE T C NET Standard ftp ftp icpdas com pub cd winpac napdos wp 8x3x ce50 demo winpac dotnet C 23 net standard gt For WP 8x4x series CD Napdos wp 8x4x_ce50 Demo WinPAC DotNE I C NET Standard ftp ftp icodas com pub cd winpac napdos wp 8x4x_ce50 demo winpac dotnet C9623 net standard WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 119 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 1 2 Demo programs for IO The table below describes the WinPAC demos that have been designed to demonstrate the expansion I O module features of the WinPAC Local
63. and Windows capable PCs WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 7 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 1 Features Software Feafures Windows CE Net 5 0 Inside Most of the popular features in MS software are included such as 1 FTP Server 2 HTTP Server 3 ASP Java script VB script 4 SQL Server Compact Edition 3 5 5 Compact Net Framework 2 0 Remote Maintenance via FTP Server and VCEP Software The FTP server is used for uploading applications or downloading data And VCEP is designed for managing the WinPAC 8000 VCEP can synchronize every movement screen keyboard and mouse actions between the PC and the WinPAC 8000 via the Ethernet By using the FTP server and VCEP you can update and manage the WinPAC 8000 remotely via the Ethernet Built In OPC Server NAPOPC CE5 is OPC server and SCADA software can easily integrate modules through it Furthermore it also provides a library which users can use to develop their by eVC C or VB Net NAPOPC_CE5 not only supports I O modules in local slots but also supports remote I O modules with the following protocols via the RS 232 485 or Ethernet 1 Modbus RTU 2 Modbus ASCII 3 Modbus TCP 4 DCON WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 8 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail s
64. aster using communication interface the pull high pull low resistor located on the power board must adjust to enable as shown below WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 155 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 5 2 WinPAC as a Slave For most of application when using one 7520 series as RS 232 485 converter its pull high pull low resistors are set to enabled Then the WinPAC 8000 and all the other devices on this network must be slave mode the pull high pull low resistors must be disabled If there are repeaters on the RS 485 network there will be pull high pull low resistors on both sides of the repeaters l 7510 232 485 Converter 7520 Series 485 Repeater 485 Repeater 7510 Series 7510 Series Slave Mode WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 156 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com When WinPAC as a slave using COM2 communication interface the pull high pull low resistor located on the power board must adjust to disabled as shown below 1 n JP1 JP2 Jee pukov Deade _ 0272 When WinPAC as a slave using communication interface the pull high pull low resistor located on the power board must set to Slave as shown below WinPAC User 8000 Manual
65. ce of this procedure will ease flash memory Warning Updating OS image will erase flash memory Please dont turn off the device during updating WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 132 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 Click Update Now to start the process 1 4 1 0 WinPAC 8000 Update Step 1 Install Boot Loader file Step 2 Erase flash disk Step 3 Install OS image Step 4 Set and save registry This installation procedure will perform the following tasks i Install boot loader file Important Warnings Be careful if the boot loader broken off in this step and cannot restart in safe mode you have to send it back to us Erase flash disk iii Install OS image iv Set and save registry WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 133 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Tips amp Warnings AN This procedure will reset the registry settings to their default settings and all of your settings will be lost During this time do not turn off the WinPAC If the update is cancelled before completion the WinPAC may become damaged and may require servicing or exchange Besides we recommend that you turn off all other applications before starting to upgrade the OS Step
66. cnet dll file the File name field Add Reference Qd ou DN SET File Mame WinPacMet dll T File Types Component Files d1L tlb exe manifest WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 88 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 4 3 Design and Build an application program Step 1 Buton Adda button object in the From1 dialog box Step 2 Right click the button object and click the Properties command Formi cs Design Start Page Object Browser Form1 E fa x F Judd J n FL AA v n E Q buttoni Im x Prem aere s Bring to Front Send to Back Lock Controls select Forml WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 89 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 On the Properties window type the OS version in the Text edit box Properties button Syetem Windows Forms Button RightToLeft Check the OS version w Testi lien Middle enter TextlmageRelation Overlay Text The text associated with the control Eg Class View el olution Explorer op Properties Step 4 In the Form1 dialog box double click the button object to open the editor window
67. cpdas com 1 2 Specifications System Software OS WinCE Net 5 0 Net Compact Framework 2 0 Embedded Service FTP server Web server supports VB script JAVA script Embedded SQL server SDK Provided DII for eVC DII for Visual Studio Net 2003 2005 2008 CPU Module CPU PXA 270 or compatible 32 bit and 520 MHz SDRAM 128 MB Dual Battery Backup SRAM 512 KB for 5 years data retain Flash WP 8x3x 128 MB 64 MB for OS image 63 MB for built in Flash disk 1 MB for registry WP 8x4x 96 MB 64 MB for OS image 31 MB for built in Flash disk 1 MB for registry Expansion Flash Memory Micro SD socket with one 1 GB Micro SD card can support 16GB microSD card Real Time Clock Year 2000 compliance seconds minutes hours date of the month month year valid up from 1980 to 2079 EEPROM 16 KB 0 8 KB for user 9 14 KB for other programs 15 16 KB for OS Data Retention 40 years 1 000 000 erase write cycles 64 bit Hardware Serial Yes Number Dual Watchdog Timer Yes Programmable LED Indicator 1 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 15 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Rotary Switch Yes 0 9 DIP Switch Yes 8 bits for WP 8431 WP 8441 WP 8831 and WP 8841 only Input Range 10 30 Vpc Isolation 1 kV Redundant Power Inputs Yes with one power relay 1 24 Vpc for alarm Capacity WP 8131
68. ctive Project k Add To Project k Dependenties Export Makefile Insert Project into Workspace Step 7 On the Project Settings dialog select the Link tab and change the value of the Entry point symbol field WinMainCRTStarup to wWinMainCRTStartup Project Settings Settings For General Debug C C Link Resources M Win32 MYCE ARMY4 Release z ccc TT Base address Entry point symbol 0x0001 0000 wWinMainCRTStartup Stack allocations Reserve Commit 75 0000 ox 000 Version information Major Project Options UARTCE lib I7 DOCE lib fnologo 0 00010000 gt fstack 0x10000 0x1000 entry wSNinMainCRTStartup lincremental no pdb ARMVAHel Demo pdb cancel WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 185 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 8 After performing above mentioned steps build the project your project should build success If not it will Show error message as follow Please continue with the following steps int sistDr bool timer n false int 0 number 8 DI number B8 Ea ClassView HesourceView FileView king UARTCE lib UARTCE dll fatal error LNK1112 module machine type THUMB conflicts with target machine type ARM Error executing link exe Ln 11 Col 17
69. d E mail service icpdas com Step 7 Insert the following code into the Editor Window char OS 32 TCHAR buf 32 pac GetOSVersion OS pac AnsiToWideString OS buf 0 OK return TRUE return TRUE unless void CSysteminfoD1g nBtnCheck s 4 f f TODO Add your control notification Step 8 Insert the include winpacsdk h into the header area Hinclude stdafx h include systeminfo h include systeminfoDdlg h ifdef DEBUG fidefine new DEBUG HEU Hundef THIS FILE static char THIS FILE _ FILE _ fendif WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 115 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 6 5 Execute the application program on WinPAC Step 1 On the Build menu click the Build systeminfo exe command Bie Edit Yiew Insert Project Build Tools Window Help 2 al db Fu 3 Compile DKinfoDlecpp ERES Build SDEmfa exe F7 Rebuild All Batch Build Clean start Debug b Update Remote Output File fs Execute 5 LiEmtao exe tir ES set Active Configuration Configurations set Active Platform Step 2 Open the web browser and type the IP address to connect the FTP server of WinPAC Step 3 Upload the systeminfo exe application to the WinPAC via the WinPAC FTP server File Edit View
70. d February 2011 189 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 On the WinPAC open a WordPad format file si Edit View Format Tools ew Open Step 3 Set up the printer Save Ctri 5 Save As Password 1 Printer PCL Laser 2 Port Network 3 Net Path ServerName PrinterName The ServerName is your PC s name or IP Print Ctrl P The PrinterName is your printer s shared name of your PC Paper Size Select the paper size Recent Files Close Ctrl File Edit View Format Tam 114 Test Pct Laser w Print Range Network wv 9 Al Net Path RD 1 User2 Anna O n E Margins inches Paper Size 4 v Left 1 25 1 Draft Mode at Advanced Right 125 Bottom AT WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 190 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 4 2 How to use printer via USB To use a shared network printer via USB please perform the following steps Step 1 On the WinPAC open a WordPad format file si Edit View Format Tools ew Open Save Ctrl 5 Step 2 Set up the printer Save As Password 1 Printer Hewlett Packard LaserJet 2 Port LETI Print Ctrl P 3 Paper Size Select the paper size Recent Files C
71. d Password field WinPAC Step 3 Press Delete button the user mp Will be deleted from the user account list WinPAC Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting Network Setting FTP Setting Users and Password System Information Auto Execution Multi serial 4 WinPAG Utility 2 0 2 1 ile Help Configuration ela User name Password The counts is used to lagir FI 2587 name Password D he servers search as Telnet FTP WebServer etc on WinF Esther p fote The accounts is used to login the servers search as Telnet gt d emp the User name and Password file will display the selected account Select a user account from the user account list Step 4 Press Setting button ETP login If the login succeeds the dialog will display when the user Login succeeds The users of FTP have been enabled right now account has been removed WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 161 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 1 3 Use a Telnet to login WinPAC from To use telnet to login WinPAC from PC please perform the following steps Step 1 On the PC side select Run from the start menu Step 2 Type cmd and then press OK button
72. d RAM can be adjusted Storage n Program Memory Memory Allocated 48456KB Allocated 48456KB In Use In Use 14988 The tab use to How to use Adjust display Move the slider left to release more memory running programs or move the slider right to release more storage room and then press the Setting button WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 78 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Backplane Compatibility Tab The Backplane Compatibility tab provides functions to keep old programs running on WinPAC without any modification the unused RAM WinPAG Utility 2 0 2 1 Auto Execution Mult serial port wizard System Memory Setting Backplane Compatbilty This setting may let WinPac support old programs which run an the following device WinPAC 8000 Port Backward Compatible for WinCon Support Devices WHR SH Series W Bxdx Series Wi BO31 8039 6 Wi BO041 3047 8049 6 44 8331 8339 6 44 8341 8347 8349 6 W B731 8739 6 W B741 8747 8749 6 The tab use to How to use Configure programs Select the COM Port Backward Compatible for running at WinCON 8000 WinCon and then press Setting button WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 79 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 Y
73. demo program is used by 87K series modules 8k dio 87k ai Shows how to read the values of Al module This demo program is used by 87K series modules Shows how to write the AO values to AO module 07k ao This demo program is used by 87K series AO modules 87k di Shows how to read the DI values of DI module This demo program is used by 87K series DI modules Shows how to write the DO values to DO module 87k_do This demo program is used by 87K series DO modules Shows how to read the and the DO values of the DIO module 87k dio This demo program is used by 87K series DIO modules Shows how to send receive a command response application This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the values of Al module 7k87k ai This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to write the AO values to AO module 7k87k ao This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the DI values of DI module 7k87k di This demo program is used by 7K or 87K series Al modules which connected through a COM port WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 126 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Demo Explanation Sh
74. e please refer to section 2 3 Configuring the Boot Mode 3 Micro SD Socket There is a Micro SD expansion slot which is used to increase memory capacity just in case 16 GB 4 VGA Connector The connector is a 3 row 15 pin connector that can be used to connect a monitor at a variety of supported VGA resolutions These resolutions range from 640 x 400 to 1280 x 1024 px WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 26 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 Expansion Slot The WinPAC includes some additional slots that can be used for expansion purposes The number of expansion slots for each model is as follows WP 8141 WP 8131 1 I O slot WP 8441 WP 8341 4 I O slots WP 8841 WP 8831 8 I O slots 6 Connector The connector has 10 pins and the pin assignments are as follows WP 8131 WP 8141 WP 8431 WP 8441 WP 8831 WP 8841 Signal Description Signal Description COM2 Lowri Power input 1 RS 485 COM1 Lano Power input 2 RS 232 output Relay Output RS 485 m o Power Input 2 PWR2 PGND Power Input 1 PWR1 gt F j x WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 27 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 7 Ethernet Port LAN1 LAN2 The WinPAC con
75. e information for the Interrupt APIs e Memory Access API Provides reference information for the memory R W APIs including EEPROM and SRAM e Watchdog Functions Provides reference information for the watchdog APIs including hardware watchdog and OS watchdog Uart API Provides reference information for the Uart APIs e Registry API Provides reference information for the registry e MicroSD Management API Provides reference information for the MicroSD Manager e PAC IO API Provides reference information for IO APIs including local and remote In additions no matter 8K or 87K modules use the same API e Error Handling API Provides reference information for error handling WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 84 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 3 2 WinPAC SDK Reference For full usage information regarding the description prototype and the arguments of the functions please refer to the WinPAC Standard API Manual located at gt For WP 8x3x series CD Napdos wp 8x3x_ce50 Document SDK_Document fto ftp icodas com pub cd winpac napdos wp 8x3x ce50 document sdk document gt For WP 8x4x series CD Napdos wp 8x4x_ce50 Document SDK_Document fto ftp icodas com pub cd winpac napdos wp 8x4x ce50 document sdk document WinPAC Standard manual 1 9 1_pdf Adobe Acrobat Pro te
76. e slave devices The WinPAC provides two RS 485 communication interfaces based on the master slave system architecture all of which have a pull high pull low resistor user can set it to master or slave for implementing an RS 485 multi drop network One of the RS 485 communications its pull high pull low resistor located on power board the other COMS located on the right side and its pull high pull low resistor located on the bottom of the right side as shown below JP1 and 2 are the jumpers settings of the pull high pull low resistor WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 153 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com D 5 1 WinPAC as a Master default When one of WinPAC is set to master then all the other devices on the same network must be slave mode If the network is up to 1 2 KM it will need a repeater 7510 series to extend the network length 7 Master Mode 485 Repeater 7510 Series 485 Repeater 7510 Series Slave Mode WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 154 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com When WinPAC as a master using COM2 communication interface the pull high pull low resistor located on the power board must adjust to enable as shown below Puller 272 f When WinPAC as a m
77. ebugging in dicic Default device PACSO ARMY4 Release ye Farm Factors TTm FT WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 176 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 7 On the 50 ARMV4 ARMV4L Release Properties dialog click the Configure button SOU ARMY4 ARMY4I Release Properties Default output location on device Program Files Folder Transport Bootstrapper me Startup Provider v configure Step 8 On the Configure TCP IP Transport dialog select the Use specific IP address option and type the IP address of WinPAC and then click the button Options EJ Ed Find and Replace Fonts and Colors pg Help 0 impor and Export Settings Par Si a RYA Relea Configure TCP IP Transport 53 Use fixed port number Device IP address C Obtain an IP address automatically using ActiveSync Use specific IP address 10 0 9 43 a WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 177 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 9 On the 50 ARMVA4 ARMYVAI Release Properties dialog click the button ARMY4I Release Properties Default output location on device
78. ecution etc Exits the WinPAC Utility WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 65 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Help Menu File LJ Configuration Reset System to Default Release Notes About The menu commands Use to Reset System to Default Resets the system interrupt status to default The operation used in the situation when the interrupt crash You can select this operation to reset the interrupt status without rebooting the device About Displays a dialog box with information about WinPAC Utility including the current version and copyright information WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 66 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Configuration Menu File Help Configuration Import Registry key Export Regsitry Key Store All Registry Setting Dump Al Registry Setting The menu commands Use to Import Registry Key Backs up a sub key of registry by using a registration entry reg file How to use Step 1 Select the Import Registry Key then the Open dialog box will appear Step 2 On the Open dialog box select a specific reg file to import Warning 1 The reg file which should be saved by Export Registry Key 2 It will not Save automatically after import a reg file Export Registry Ke
79. edundant Ethernet communication and separate Ethernet communication one for global Internet one for private Ethernet Redundant Power Input To prevent the WinPAC 8000 from failing by the power loss the power module is designed with two input connectors Once a power input fails the power module switches to the other power input And there is a relay output for informing the power failure Ventilated Housing Design Allows Operation Between 25 75 C Each WinPAC 8000 is housed in a plastic based box with a column like ventilator that can help to cool the working environment inside the box and allow the WinPAC 8000 operating between 25 C and 75 C WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 12 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com WinPAC 8000 provides the following I O expansion bus Local I O Slot There are 1 4 8 slot options to expand local I O And the I O modules can be parallel bus type high profile 8K series and serial bus type high profile 87K series The difference between them is Item I 8K Series 87 Series WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 13 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Ethernet The available Ethernet I O devices ET 6000 ET 7000 1 8 4 8 and l 8KE4 8 MTCP WinPAC 8000 can access them with Modbus TCP or
80. er communication protocols It also provides one advanced function Rule Script for use in the integration and transformation and some conditional Logic operation Any version before 2 1 0 of the NAPOPC CE5 was named Quicker WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 60 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 3 SendToCOM The SendToCOM uses the serial port to communicate with expansion module To use the Send ToCOM you can send data to expansion module through the serial port and receive data from other device through the serial port For more information about these commands for communicating with expansion module please refer to CDANapdosNo module 87k high profile modules htm ICPDAS Send to COM v2 00 Connect ion Stal 9 a pu au zx E BE End st rir g with S gt CLF ye Autc Interna m set WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 61 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 4 VCEP Manage Your WinCon From Anywhere ICPDAS VCEP is designed for managing your WinPAC anywhere No matter where you are ICPDAS VCEP provides a convenient environment on the Desktop PC and allows you control your WinPAC remotely ICPDAS VCEP is composed of two main components T
81. ervice icpdas com Rich Software Solutions ISaGRAF Indusoft WinPAC VS net 2003 2005 2008 On the WinPAC 8000 ICP DAS provides the following software solutions to fit in different applications 1 Visual Studio Net 2003 2005 2008 and eVC solution SDK as well as demo programs for VB Net and eVC are provided 2 SoftPLC solution A ISaGRAF supports IEC61131 3 languages Ladder Diagram LD Structured Text ST Function Block Diagram FBD Sequential Function Chart SFC Instruction List IL and Flow Chart FC B KW software supports IEC61131 3 languages and HMI features 3 SCADA solution Indusoft provides simple drag and drop point and click developing environment for HMI and SCADA applications WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 9 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Upgrading applications from WinCon to WinPAC just copy and play Copy amp Play is WinCon 8000 WinPAC 8000 Users can upgrade their controller from WinCon 8000 to WinPAC 8000 and meanwhile still keep most of their old applications exe file running smoothly on WinPAC 8000 without any modification The only thing that users have to do is just to copy the exe file from WinCon 8000 paste it to WinPAC 8000 and then play it How simple it is And for exceptions that old applications exe file are not able to follow the
82. f the WinPAC to search the I 87K series expansion I O modules IP 10 1 0 50 Connect COM 3 RS232 RS 485 Step 5 Select the module name that you want to configure Fi DCON UTILITY YER 506 The Found Out I O module File COM Port Search Eun Terminal Language Help madule wincon O00 1 I SENE 50 115200 onfiguration for 87055 Yersion 108 51 115200 52 115200 MEMME 53 115200 87055 54 115200 S5 115200 is Digital Output 14 xE REM 36 115200 LSB 0 57 115200 d audit Configuration Setting Modbus Response Delay Time Setting Protocol N _ Delav Time 0 30 ms ettina Address ad Baudrate ma Power On Yalue of DO Safe Yalue of DO Searching Status Checksum set Value SetValue TCP IP Address 10 1 0 58 Parity Option None Part B Read Value Read Value Enable WDT First Digital Input j 0 0x00 LSB CH 0 MSB CH Host Watchdog Setting Timeout 255 0 1 25 5 sec Send Host OK Latch Counter Enable WDT Setting et Exit WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 49 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 6 Changing the User Interface Language The WinPAC is a Windows CE based operating system which provides mult
83. ges in section 2 6 Added information about installing the touch panel driver in section 2 7 Added information about the Multi serial port wizard function of the WinPAC Utility in section 35 Added additional information about the revision history in Appendix F September 2009 1 Added a section about the module selection in 1 2 2 Added information about the support of the printer WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 195 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com driver in Appendix E 4 October 2009 1 Modified the specification of the flash disk in section 1 1 and 1 2 2 Deleted auto mdi mdi x or auto mdix to Ethernet port specification 3 Added additional information about the support of the Micro SD socket in section 1 2 4 Modified the printer configuration in Appendix E 4 October 2009 1 Added information about two new OS mode DCON CE and VCEP mode in section 2 3 2 Replaced Quicker with NAPOPC CE5 2 0 0 November 2009 Added information about WP 8x3x series modules December 2009 1 Modified the WinPAC installation in section 2 1 2 Added information about the requirements of the WinPAC SDK in section 4 3 April 2010 1 Modified the specification of Dual Battery Backup SRAM feature in section 1 1 2 Added information about Expansion Slots in section 1 2 3 Modified information about Operating Environment in section 1 2
84. get any problems caused by updating the WinPAC Utility software please feedback to your local seller and ask essential helo amp Seyi ces WinPAC Utility MN Leur noe 2 0 1 1 Jul 2005 WP 8x4x WP 8Sx3x Tools to save view the system information registry and setup the HTTP FTP path and update nan valatile internal memory within WinPFAC 8000 The following update categories are available from the WinPAC Download Center Y OS images Includes updates and the latest version of WinPAC OS Y WinPAC SDK Includes updates and the latest version of each WinPAC component SDK such as WinPAC SDK NAPOPC CE5 SDK Modbus SDK etc Y Utility amp Tools Includes updates and the latest version for WinPAC toolkits Y Demo Includes all related WinPAC demos Y Documents Includes updates and the latest version for related WinPAC documents Y System Disk Includes updates and the latest version for WinPAC toolkits WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 144 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Appendix A Frame Ground Electronic circuits are constantly vulnerable to Electro Static Discharge ESD which become worse in a continental climate area Some l 7000 M 7000 and l 8000 series modules feature a new design for the frame ground which provides a path for bypassing ESD allowing enhanced static protection ESD capability and ensures that the module is more
85. hdog Yes Heal Time Clock Yes WinPAC 8000 User Manual version 2 0 5 Copyright 2009 ICP DAS Co Ltd All Rights Reserved 16 KB Micro SD slot Default 1 GB USB1 1 x 1 VGA port x 1 640 x 480 800 x 600 RJ45 x 2 10 100 BaseTX For 1 87 module in slot RS 232 RS 485 RS 232 485 RS 232 1 4 8 Yes Yes Yes 16 KB Compact Flash type Default 1 GB USB1 1 x 1 PS 2 port x 2 Keyboard and Mouse VGA port x 1 320 x 240 768 1024 x RJ45 x1 10 For 1 87 module in slot RS 232 RS 485 0 3 7 Yes Yes for Reset Yes Yes Last Revised February 2011 16 KB Compact Flash type Default 1GB USB1 1 x 2 VGA port x 1 320 x 240 1024 x 768 RJ45 x 2 10 100 Basel X For 1 87 module in I O slot RS 232 RS 485 0 3 7 Yes Yes For Reset Yes Yes Page 36 E mail service icpdas com WP 8x3x WP 8x4x Yes 3 d DIP Switch 8 bit Yes Rotary Switch Yes 0 9 Yes 0 9 Yes 0 2 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 37 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 Getting Started This chapter describes installation basic configuration and fundamental operating principle needed to install and set up the WinPAC 2 1 Mounting the Hardware Step 1 Mounting the WinPAC The WinPAC installation must provide pr
86. he Server which runs on WinPAC The Client which runs on a Desktop PC Once a connection is established between the client and server initiated by the client the client will periodically send requests for screen updates and send mouse key click information to the server to simulate Each video frame is inter compressed against the previous frame and then intra compressed with a modified LZW scheme to minimize the amount of data transmitted from server to client For more detailed information on VCEP application please refer to http www icpdas com products PAC wincon 8000 wincon VirtualCE htm WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 62 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 5 WinPAC Utility The WinPAC Utility is a tool which is designed to quickly control and manage the WinPAC WinPAC Utility 2 0 2 1 File Help Configuration Ethernet Setting Network Setting System Information Auto Execution Multi serial gt Welcome to use WinPAC Utility This tool will help you to set 8000 Display Resolution 600 WinPAC Industrial Control Products Re Data Acquisition System Batteryl OK Task Bar Setting Auto Hide Always Batterye OK Empty Desktop Change HTTP document root directory Windows wea a w LB to o inicios n Sn vv LIB zd Configure the synchronization with a time
87. ilingual user interface and the user interface can be set to one of multi languages Step 1 Open the Control Panel ag Programs d dz Favorites d iE Documents E Settings E Control Panel e Network and Dial up Connections a Taskbar and Start Menu 5 i M Virtual CE Step 2 Run the Regional Settings BA Step 3 Choose the display language and then click OK Regional Regional and Language 5e Settings Language User Interface Language The option will determine the language used for the menus dialogs and alerts English United States English United States German Germany Russian WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 50 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 Run the WinPAC Utility located on desktop teens ort werg vmm tmm rtr mmm am tm mm aanert c LASER AN A vw mer Step 5 Save and Reboot Help Configuration FTP Setting Syste Save and Reboot Reboot Without Save 320 240 Restore Default Settings Exit r E Always on Top Change HTTP document root directory to Setting WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 51 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 7 Installing the Touch Panel Driver
88. inpac napdos wp 8x4x_ce50 demo winpac dotnet c9623 net pac io WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 122 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 2 Demo Programs with eMbedded Visual The following eVC demos have been designed to demonstrate the various features of the WinPAC 5 2 1 eVC Demo programs for WinPAC Standard API The table below describes the WinPAC demos that have been designed to demonstrate the standard operation features of the WinPAC system Information Watchdog Backplane Access UART Interrupt Registry Memory Access Micro SD WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 123 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com WinPAC Standard API Folder Demo Explanation Hetrieves information about the DIP switch backplane ID and slot count Shows how to read write date values Memory from to EEPROM memoryaccess Shows how to read or write to the battery backup sram battery backup watchdog watchdog Displays how the watchdog operate Shows how to enables disables microsd microsd management Micro SD Shows how to read write date values registry registry from to registry m Shows how to read the name of local I O modules via UART For eVC application these demo programs can be obtained from
89. k box in the FTP field Disable Select the Disable check box in the FTP field Enable or disable Enable anonymous FIP Select the Enable check box in the Allow Anonymous field access Disable Select the Disable check box in the Allow Anonymous field Enable or disable Enable anonymous FIP Select the Enable check box in the Allow Anonymous upload Upload field WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 72 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com The tab use to How to use Disable select the Disable check box in the Allow Anonymous Upload field Change the FTP Enter a new path in the Change default download directory path directory field and then press the Setting button WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 73 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com The FTP settings tab provides functions to add delete and manage the user account for FTP telnet and Web server access WinPAC Utility 2 0 2 1 System Setting Ethernet Setting Network Setting FTP Setting Users and Password User Password Username Password Note The accounts is used to login the servers search as Telnet FTP WebServer etc on WinPAC The tab use to How to use Fill in the User name and Password field of your user
90. kage file exe and the corresponding Autolnit bat file to WinPAC and then double click installation package file to run it Upgrade Install amp Autolnit be Below is a step by step procedure for updating the WinPAC OS Step 1 Get the latest version of the installation package file and the corresponding Autolnit bat file downloading to WinPAC The latest version of the installation package file and the corresponding Autolnit bat file can be obtained from gt For WP 8x3x series CD ANapdosWp 8x3x ce50 VOS from file http ftp icpdas com pub cd winpac napdos wp 8x3x 50 image update from file gt For WP 8x4x series CD Napdos wp 8x4x_ce50 OS_Image update_from_file http ftp icpdas com pub cd winpac napdos wp 8x4x ce50 os image update from file WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 131 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com The corresponding Autolnit bat file can be obtained from the same folder There are several ways to download the installation package file and the corresponding file to WinPAC i On the WinPAC you can download these files via Ethernet connection ii On the PC you can download these files via a USB storage device the removable Micro SD card or FTP server Step 2 Run the installation package file and then click OK to make sure you receive the important noti
91. l service icpdas com Copyright 2009 ICP DAS Co Ltd All Rights Reserved Step 3 In the systeminfo dialog box right click the button object and then click the Properties command EZ SDEinfo IDD SDEINFO DIALOG German Germany Dial BEES Copy Paste Insert Active Control ZU ERLED Dialogfeld Steuen mize to Content ES Align Lett Ed ges Alien Edges Check Mnemonics Events Properties Step 4 Type the Check the OS version in the Caption edit box and then click the close button Push Button Properties 40 General Styles Extended Styles ID IIDC BUTTONI Caption Check the OS version Visible Group Disabled Tab stop WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 113 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 In the systeminfo dialog box double Click the button object Double click ZU ERLED DialagFeld Steuerelerr the button Step 6 Type the OnBtnCheckOS in the Member function name edit box and then click the OK button Add Member tii function name OnBtnCheckOs Cancel Message BN CLICKED Object ID IDC BUTTON WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 114 Copyright 2009 ICP DAS Co Ltd All Rights Reserve
92. latform PAC270 S TANI Directories t CAProgram Files indows CE Toolstwce5O0 s TANDARDSDE 5 0VncludeVA CAProgram Files findows Toolstwce5O00 STANDARDSDE 5SO00tmic inclu Click this button to specify the header file include path WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 109 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 In the Option dialog select the Directories tab and do the following in this order to specify the library file path The specified include path of the library file is default located at C Program Files Windows CE Toolswce500 PAC270McpdasVLibAARMVAM Options a Directories kspace Macros Format S bpasdiseobesis T Suber fies Download Bi Platform 270 S TANI Win32 UE ARMY AI Directories ot CAProgram Files indows CE ToolstwceS50O0 S TANDARDSDK bVAR MV CAProgram Files indows CE Tonlstwceb nDAS TANDARDSDK 50 0mfcMibVAF HILF Ih AE Click this button to specify the library file path WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 110 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 Click the Settings command from
93. lose Ctrl File Edit View Format Tools cmm E Tahom m 14 m Test Printer Hewlett Packard Laser Print Range Orientation Part al 3 Portrait Selection Landscape Met Path O 4 Paper Size 4 v Margins inches Draft Mode LER a5 Ve B Color Right 1 25 Bottom 1 Advanced WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 191 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 5 How to use services tool The services tool can help you turn on turn off and monitor the WinCE services Step 1 Open a MS DOS command prompt 1 Programs de Favorites 3 Documents GF Settings Type the name of a program folder or document and Windows will open it for you Open End WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 192 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 List all services Syntax services list File Edit Help Pocket CHD x 5 0 0 00030110 TPO OxO0O031570 OxO0032Z070 l ax adgpgs3e739 0 x n se ebz x n0g37770 ax dggs37ac OxOO00se3e0 TPO HITPD DLL credswvo dll HMSH DP Dll OBESSrVr dll IELNEID DllI smbserwver dll timezwvc dll Punnindg Bunning Off
94. me To File select Image Exit gt pen Lock rc jen Of 2G 4 og VF ho 20090506 Ver 00 5 en ban select Image My Piece Documents Microsoft Windows CE Debug Shell VP 44498 20 File Edit Tools Options View Help als al af zs viel UP 44498 Bootloader Version 1 8 IP 16 1 6 56 MAC 68881F6816DD2 xL Downloading Rdfs cd_2 WinPAC napdos up 2666_ceS56 0S_image up 23w1 update_from_Eshell en ul Jumping to image on UP_44498 Connecting to UP 44498 using Ethernet WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 138 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 6 Once the procedure is completed the Warning dialog box will Appear on WinPAC screen as below shown click to finish the process Warning Please turn the rotary switch to 0 normal made and reboot the device Would you like to reboot right now or later Step 8 Run the WinPAC Utility to save the settings and reboot the WinPAC Run the WinPAC Utility and then select the Save and Reboot command from the File menu to save the settings and reboot the WinPAC Help Configuration Save Setti Save and Reboot FTP Setting lt Reboot Without Save esalution 320 240 Restore Default Settings
95. n CSDKinfoApp in SDKinfo h and SDKinfo cpp Dialog CSDKinfoDIg in SDKinfoDlg h and SDKinfaDlIg cpp View CChildView in ChildView h and ChildView cpp Features Uses shared DLL implementation Localizable text in Hes 22 8 Project Directory CADOCUMENTS AND SETTINGS WINDOWS CE TOOLSAEVCYSDKinfo Cancel WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 106 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 6 2 Configure compiler options On the WCE configuration toolbar select the Win32 WCE ARMV4 Release eq SDEinfo Microsoft eMbedded Visual Bil Edit View Project Build Tools Window Help amp e 2 c mms EIE CSDKintoApp l i All class members CSDKinfoApp dE B EIL mmy ee WCE ARVAN Release MYCE ARMYAI Release STANDARDSDK 500 Emulator Wind WCE ARMV4I Debug Win32 Release SDKinfo classe DKinfo classes in32 CE emulator Debug in32 WCE emulator Release in32 WCE MIPSII Debug Inge WCE MIPSII Release in32 MIPSIL FP Debug in32 MIPSIL Release in32 MIPSIV Debug Inge WCE MIPSIV Release 132 MIPSIV FP Debug in32 MIPSIV Release in32 SHA Debug inj SH4 Release in32 W CE x86 Debug WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 107 Copyrigh
96. n be obtained from gt For WP 8x3x series http ftp icpdas com pub cd winpac napdos wp 8x3x ce50 sdk winpacsdk gt For WP 8x4x series http ftp icpdas com pub cd winpac napdos wp 8x4x ce50 sdk winpacsdk Step 2 Copy the latest version of header files and libraries to Host PC The header files are located at C Program Files Windows CE Tools wce500 PAC270 Icpdas Include ARMV4 I The libraries are located at C Program Files Windows CE Tools wce500 PAC270 Icpdas Lib ARMV4 Step 3 Copy the latest version of DLL files to WinPAC The DLL files are located at System_Disk ICPDAS System WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 143 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 7 WinPAC Download Center This chapter introduces the WinPAC Download Center Visit the WinPAC Download Center http www icpdas com products PAC winpac download winpac 8000 download os ima ges htm WinPAC 8000 Download Center Hate When you download the software programs you should notice if the programs conform to your machine The published date and indicated requirement of program can help user ta determine the compatibility for your WinPAC BDDD Before you download any program please read the notes of each online program first to avoid the confused situation Utility amp Tools Note User should consider the suitability over his application If you
97. n be selected at a time and the configuration depends on TxD the pin connections as described below RS 232 RXD TXD CTS RTS and GND RS 485 Data and Data No software configuration or hardware jumpers are needed 11 COMA RS 232 Port Type Male Baud Rate 115200 57600 38400 19200 9600 4800 2400 1200 bps Data Bits 5 6 7 8 Parity None Even Odd Mark Always 1 opace Always 0 Stop Bits 1 2 FIFO 16 bytes 12 DIP Switch 8 bits The DIP switch can be used to set the Module ON ID to a number from O to 255 Do not use Module ID 0 for communication E E E E I E WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 30 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 5 Companion CD This package comes with a CD that provides drivers software utility all of the required documentations etc All of them are listed below CD napdos L 8 3 _ 50 8 4 _ 50 Backup Backup files related to the documents OS images SDKs etc Demo Demos related to WP 8x3x WP 8x4x Document Document related to WP 8x3x WP 8x4x eLogger Demos and drivers related to eLogger Micro_SD Tools and drivers related to manage the microSD misc Files related to miscellaneous OS Image OS Image related to WP 8x3x WP 8x4x PC_Tools Tools related to management WP 8x3x WP 8x4
98. nnectiona dll pro perty port S000 system disk icpdas system fixed port number 2000 Device IP address Obtain an IP address automatically using ActiveSync 9 Use specific IP address 10 0 9 10 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 181 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 3 How to recompile WinCon programs To recompile Wincon programs to run on WinPAC certain components of the programs require an adjustment that divides into two parts 1 Compiler old programs which ran on Wincon 8x3x and 8x4x 2 Modify vcp file to upgrade the old WinCon project Tips amp Warnings In general you only need to do part 1 after this if the program still can t be compiled to an application the part 2 just need to do WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 182 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 3 1 Compiler old programs which ran on Wincon 8 3 and 8x4x Step 1 Open project which programmed in WinCon using eMbedded Visual Step 2 On the Build menu click Configurations command Edit View Insert Project Build Layout Tools Window Help 2 Compile Cti F7 Build HELLO exe E Rebuild Batch Build lean start Debug Update Remote Output File s f Execute HE
99. oject 2 Configure compiler options 3 Design and Build an application program 4 Execute the application on the WinPAC All main steps will be described in the following subsection 4 6 1 Create a new Forms Based project Step 1 Start the Microsoft Embedded Visual Step 2 From the File menu click the command File Edit View Insert Project Build Tools Window Help Files Projects Workspaces Project name WCE ATL COM AppWizard FO WCE Dynamic Link Library fir WCE ActiveX ControlVizard Location i WCE AppWizard dll MFC AppWizard exe CAWINDOWS CE TOOLSACI E amp WCE Static Library Create new workspace Add to current workspace Dependency of Recent Files Recent Work V Win32 WCE ARMY4 eee ie Win32 WCE ARMVAI Win32 WCE ARMVAT Exit OWin32 WCE 16 ie Win32 WCE MIPSII i Win32 WCE MIPSII x Leet WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 102 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 In the New dialog select the Projects tab and do the following in this order New Files Projects Workspaces a YYCE Application CE ATL COM AppWizard systeme J WCE Dynamic ink Library ls WCE ActiveX ControlVWizard Appvvizari 0 WCE AppWizard exe 4 CAWINDOWS CE TOO
100. olbox Add in Manager Macros Create GUID L atfuscator Community Edition External Tools Device Emulator Manager Import and Export kettings Lustonuze WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 179 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 13 On the Connect to Device dialog select 270 from Platform list and then click the Connect button Connect to Device To connect to a physical device or launch emulator image select a platform then choose a device below Step 14 On the Tools menu click Connect to Device command Connecting FACSO ARMY4 AEMVAI Release Connection succeeded Step 15 Connection established Then you can debug on line WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 180 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com If the connection fails shown as follow return to step 11 to do the action below Io PACSU ARMVY4 AEMVAI Release Connection failed A cteeeswme is not installed Open the command prompt run the CommanClient2 exe transport tcpconnectiona dll property port 5000 id Con at System_Disk ICPDAS System and then run the CMAccept exe 9 system disk 1 4 system gt 1 2 transport tcpco
101. om pub cd winpac napdos wp 8x4x ce50 os update from Eshell WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 136 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 Run the ESHELL on the PC ESHELL you be obtained at ESHELL gt For WP 8x3x series CD Napdos wp 8x3x_ce50 PC_Tools http ftp icpdas com pub cd winpac napdos wp 8x3x 50 tools gt For WP 8x4x series CD Napdos wp 8x4x_ce50 PC_Tools http ftp icpdas com pub cd winpac napdos wp 8x4x 50 tools Step 3 Configure the reboot in OS update mode Turn the rotary switch to 3 and then reboot the WinPAC Step 4 Select the device which you want to update the OS image After starting the ESHELL software the Select Device dialog will appear and then select the device which you want Select Device Enter Device wWINPAC270 535 Or Select From the List YO 535 Reset devices to automatically put names on the list WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 137 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 Select the latest version of the OS image file F Microsoft Windows CE Debug Shell WINPAC270 626 gig Edit Tools Options View save Curent Log As Cth A 10 start Losine To Fie otop Loge
102. op Debugging button from Debug menu BE Edit View Insert Project Debug Layout Tool Window Help FS Restart Ctr hift F5 Break m step Into Fil step wer FIO P Step 1 Eun te Cursor CCETEFTU Eh Exceptions Threads Modules Be show NextStatement Alt Num ge Quick Watch WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 173 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 2 2 Debug WinPAC programs in Visual Studio 2005 2008 Debugging in Visual Studio 2005 2008 are provided by WinPAC OS image V 1 3 0 4 or later Step 1 Make sure the following file are listed with the matching version numbers C Program Files Common Files Microsoft 1 ActiveSyncBootstrap dll shared CoreCon 1 0 Bin 2 ConMane2 dll 3 ConManPS dll 4 DesktopDMA all 5 eDbgIL adll 6 TcoConnectionC dll Shared CoreConM 0 1 033 C Program Files Common Files Microsoft 1 DeviceDMA dll shared CoreCon 1 0 Target wce400 armv4i 2 eDbgTL all TcoConnectionA dll 4 clientshutdown exe 5 CMAccept exe 6 ConmanClient2 exe Step 2 If the version matches correctly and the entire file are there copy the following files to WinPAC System DiskVCPDAS System folder v Clientshutdown exe v ConmanClient2 exe v CMaccept exe v eDbgTL dll v TcpConnectionA dll WinPAC 8000 User Manual version 2 0 5 Last Revised Februar
103. oper ventilation spacing and grounding to ensure the equipment will operate as specified A minimum clearance of 50mm between the WinPAC and the top and bottom side of the enclosure panels must be provided There is a minimum of 50mm clearance between the top and bottom edges of the WinPAC and the enclosure panels WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 38 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 Connecting power and I O device The diagram below shows the connections of the 1 slot of the WinPAC A The input range of power supply is 10 30 Voc VS GND The diagram below shows the connections of 4 8 slots module of the WinPAC WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 39 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 2 Inserting I O Modules The I O slots support parallel bus type high profile I 8K series and serial bus type high profile I 87K series modules There are more than 60 kinds of module for Al AO AO counter input frequency input PWM output motion control memory communication etc For more information about expansion module that are compatible with the WinPAC please refer to htto www icodas com products PAC winpac io support list htm Tips amp Warnings It is recommended that the powe
104. or allows user to editor the registry value of Windows CE Operating system e RegistryViewer The Registry Viewer allows user to view the registry value of Windows CE Operating system e Remote display application The remote display application allows user to view the display remotely of the WinPAC on a Host PC e SendToCOM The SendToCOM allows user to send receive data to from the expansion module via serial port e TaskMgr The TaskMgr provides details about programs and processes running on the WinPAC e VCEP The VCEP allows user to manage the WinPAC remotely on a Host PC For more information about the VCEP please refer to 3 4 VCEP Virtual CE Pro e WinPAC Utility The WinPAC Utility provides various useful functions such as configuring Ethernet settings monitoring system settings and FTP services etc for easy and quick management For more information about the WinPAC Utility please refer to 3 5 WinPAC Utility WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 58 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 1 DCON Utility DCON Utility ag Ea r 8 Protoco ASCII Command 7188 8000 o age I 87K Series 1 7000 Series 1 8000 Series The DCON Utility is a toolkit that help user search the network easily to Configure the I O modules and test the I O status via the serial port RS 232 485 or Ethernet
105. our First WinPAC Program This chapter describes the components of the WinPAC SDK and provides step by step tutorial for developer that will teach you how to create your first WinPAC program Before writing your first program ensure that you have the necessary development tools and the corresponding WinPAC SDKs are installed on your system 4 1 Preparing the Development Tools There are several programming tools available for application developers targeting Windows CE based WinPAC One of the following tools must be installed on the Host Y Microsoft eMbedded Visual Visual Basic net v Visual C WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 80 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 2 Installing WinPAC SDKs The WinPAC SDK is a Software Development Kit SDK that contains C header files C libraries and documents Below is a step by step procedure for installing the WinPAC SDKs Step 1 Insert the CD into your CD ROM drive Step 2 Execute the 270 SDK_YYYYMMDD msi which is located in gt For WP 8x98x series CD Napdos wp 8x3x_ce50 SDK gt For WP 8x4x series CD Napdos wp 8x4x_ce50 SDK Step 3 Follow the prompts until the installation is complete WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 81 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com
106. ows how to write the DO values to DO module 7k87k do This demo program is used by 7K or 87K series Al modules which connected through a COM port Shows how to read the DI and the DO values of the DIO module This demo program is used by 7K or 87K series Al modules which connected through a COM port 7k87k dio For eVC application these demo programs can be obtained from gt For WP 8x3x series CD Napdos wp 8x3x_ce50 Demo WinPAC eVC PAC_IO fto ftp icodas com pub cd winpac napdos wp 8x3x ce50 demo winpac evc pa C 10 gt For WP 8x4x series CD Napdos wp 8x4x_ce50 Demo WinPAC eVC PAC_IO ftp ftp icodas com pub cd winpac napdos wp 8x4x_ce50 demo winpac evc pa C 10 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 127 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 WinPAC Updates This chapter provides instructions on how to upgrade WinPAC OS and SDK ICP DAS will continue to add additional features to WinPAC SDK and OS in the future so we advise you to periodically check the ICP DAS web site for the latest updates WinPAC updates services can be divided into the following two main categories CD Napdos Wp 8x3x ceb0wp 8x4x ce50 BEEBE EEG 1 0Su dates os_image gt 2101010 update_from_Eshell update from file lt 2 SDK updates SDK IO Modules Modbus NAPOPC CES5
107. plication on the WinPAC Step 1 On the Build menu click the Build Solution command File Edit View Project Debug Data Format Tools Test Window Build Solution ChhShfHB Rebuild Solution Deploy solution lean Solution Build systeminfo Rebuild syetemuntio Deploy zvsteminto Clean systemunto Batch Build Configuration Manager Step 2 Open the web browser and type the IP address to connect the FTP server of WinPAC Step 3 Upload the systeminfo exe application and the corresponding Winpacnet dll file to the WinPAC via the WinPAC FTP server WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 100 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Tips amp Warnings N For applications programming in and VB net with net framework when executing these application on the WinPAC controller the corresponding Winpacnet dll file must be in the same directory as the exe file File Edit View Go gt Step 4 On the WinPAC execute the uploaded file WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 101 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 6 Your First Program in eMbedded Visual To create a demo program with eMbedded Visual development tool includes the following main steps 1 Create a new Forms Based pr
108. port using virtual com port It supports not only the DCON Protocol I O modules but also the M Series I O Modules Modbus RTU M 7K M 87K and will support Modbus ASCII M 87K now For more detailed information on WinPAC Utility applications please refer to 2 5 Using Utility to configure the I O modules WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 59 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 2 5 ji _ DA Server is a free OPC DA Server The 2 stands for OLE for Process Control and the DA stands Data Access working on WinPAC ViewPAC amp WinCon controllers provided by ICP DAS Ltd The first standard originally called simply the OPC Specification and now called the Data Access Specification resulted from the collaboration of a number of leading worldwide automation suppliers working in cooperation with Microsoft Originally based on Microsoft s OLE COM component object model and DCOM distributed component object model technologies the specification defined a standard set of objects interfaces and methods for use in process control and manufacturing automation applications to facilitate interoperability NAPOPC_CE5 DA Server integrates OPC Modbus TCP Slave and Modbus RTU Slave three kind Slave services as well as integrates Modbus TCP Master Modbus RTU Master and DCON three kind Mast
109. r to the WINPAC 8000 is switched off when wring the I O module which are plugging in the WINPAC 8000 slots WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 40 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 1 Read the relevant documentation The documentation for I 8K series modules is located at CD module http www icpdas com products PAC winpac io support list htm The documentation for 87 series modules is located at CD module http www icpdas com products PAC winpac io support list htm WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 41 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 Wiring Connections All documents include the I O module specifications pin assignments and wiring connections For example Pin Assignments and Wiring connections for the I 8 054W module are as follows Pin Assignments DI COMO DIO DI 012 013 E E DI COM 05 samen LOS O amp A DI6 017 pus 06 a Hv Open Collector On Open Collector Off 002 NPN C Output IE za EIE I PNP E poe tss je tis Wire Connection p DOx oz Se ers DOx DO GND DO GND WinPAC 8000 User Manual version 2 0 5 La
110. ransport and a startup server Choose Test to verify that vou can establish a connection to your target device with the selected transport and startup server Transport Transport for Windows CE startup server Manual Server Cancel Test WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 165 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 On the TCP IP Transport Configuration dialog select the Fixed port check box and then click the OK button TEEME Transport Confizuraton Configuration Far device 270 Device Check connection status Interval msec 60000 Part number 5000 Use fixed address 10 0 3 52 C Configure automatically over serial Cancel Step 5 On the Windows CE Platform Manager Configuration dialog click the Test button Device Properties Device Name Device select a transport and a startup server Choose Test to verity that you can establish a connection to your target device with the selected transport and startup server Transport Transport for Windows CE configure startup Server Manual Configure Cancel WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 166 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com
111. rk version SOL CE Version 1 Eh oy Oo C Last Save Date December 06 2010 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 75 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Auto Execution Tab The Auto Execute tab provides functions to configure programs running at WinPAC startup it allows users to configure ten execute files at most order of program 1 program 2 etc AN The allowed file types are exe and bat and they are executed in WinPAG Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting Network Setting System Information Auto Execution Program 1 System_Disk Tools VCEPw_remote exe Program 3 At most 10 programs can be 9 AVENUE execute 2 system startup The tab use to How to use Configure programs Press the Browse button to select the execute file running at startup which you want and then press the Setting button WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 76 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Multi Serial Port Wizard Tab The Multi serial port provides functions for installation of the RS 232 RS 422 RS 485 communication module driver oi Item RS 232 RS 422 RS 485 Isolation Connector I 8112iW 2500 Vrms DB 9 x 2 ae 4 srt o
112. serial 4 gt MAC Address 1 UU OD ED 30 01 6C LAN 1IP Address Setting Use DHCP to get IP address Assign IP address Address 10 1 0 61 Mask 255 255 0 0 Gateway 10 1 0 254 DNS Server 10 0 0 3 The tab use to How to use Configure the network Obtaining an IP address automatically from settings DHCP select the Use DHCP to get IP address option Manually assign an IP address Select the Assign IP address option Monitor the MAC address see the MAC Address 1 and MAC Address 2 fields that display the physical address of LAN1 and LAN2 WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 71 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Network Setting Tab The Network Setting tab includes two tabs FTP Setting and Users and Password The FTP settings tab provides functions to enable disable the FTP access enable disable anonymous access and configure the FTP directory path WinPAC Utility 2 0 2 1 File Help Configuration System Setting Ethernet Setting System Information Auto Execution Multi serial 4 gt FIP Setting Users and Password 3 Enable JDisable Allow Anonymous Enable Disable Allow Anonymous Enable Disable Upload Change FTP default download directory Temp to m The tab use to How to use Enable or disable Enable the FTP access Select the Enable chec
113. solution lean Solution Build systeminfo Rebuild syetemuntio Deploy zvsteminto Clean systemunto Batch Build Configuration Manager Step 2 Open the web browser and type the IP address to connect the FTP server of WinPAC Step 3 Upload the systeminfo exe application and the corresponding Winpacnet dll file to the WinPAC via the WinPAC FTP server WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 92 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Tips amp Warnings N For applications programming in and VB net with net framework when executing these application on the WinPAC controller the corresponding Winpacnet dll file must be in the same directory as the exe file File Edit View Go gt Step 4 On the WinPAC execute the uploaded file WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 93 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 5 Your First Program in VB net To create a demo program with development tool includes the following main steps 1 Create a new project 2 Add project reference for an application 3 Design and Build an application program 4 Execute the application on the WinPAC All main steps will be described in the following subsection 4 5 1 Create a new project Step 1 Start the Visual Studio 2005
114. ss the printer you can connect to the printer via Ethernet network or USB Tips amp Warnings WinPAC only supports HP Laser Jet Printers which support PCL6 driver WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 188 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E 4 1 How to use network printer To use a shared network printer please perform the following steps Step 1 On the Host PC check the name of the Host PC and the shared printer System Properties Hemote Advanced System Restore Automatic Updates Computer Mame General Hardware Windows Uses the following information to identify your computer on the network For example Kitchen Computer ar Mary s To use the ROT KEYIM_WIMPAC Properties domain and cre ou can share this printer with other users on your network enable sharing for this printer click Share this printer Do not share this printer _ Drivers IF this printer i shared with users running different versions Windows you may want to install additional drivers that the users do not have to find the print driver when they connect to the shared printer Additional Drivers WinPAC User 8000 Manual version 2 0 5 Last Revise
115. st Revised February 2011 42 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 3 Configuring the Boot Mode The WinPAC has five operating modes that can be determined through a rotary switch The table below lists the operation mode selection Rotary switch position Modes of operation Normal mode Default Safe mode Debug mode OS update mode Development mode DCON VCEP For user Normal mode Default Normal mode is the default mode of operation and the one you will use most of the time Use this mode for more tasks and configurations Programs also are executed in this mode Safe mode oafe mode is a trouble shooting The mode loads the minimum required device drivers and system services to boot the WinPAC If you have malicious software or a program caused the WinPAC cannot be boot or run the normal mode you can boot in safe mode to solve the problem WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 43 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Tips amp Warnings In normal mode if the new settings are not saved when you AN change and save the settings using the WinPAC Utility to solve this problem perform the following steps Step 1 Restart the WinPAC in safe mode Turn the rotary switch to 1 and then restart the WinPAC Step 2 Start the WinPAC Ultility to restore
116. t 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 6 3 Specify the path for project reference Step 1 Click the Options command from the Tools menu E File Edit Yiew Insert Project Bvid Tools Window Help pourrie Browser lose source Browser File fi Error Lookup Remote Call Profiler WICESOO A5 Remote File Viewer 500 Remote Heap Walker CWICESUU ft Remote Kernel Tracker OW CESOO Pa Remote Performance Monitor WCEBOUQ f Remote Process Viewer MCESO0 Remote Registry Editor WICESUD Remote CESO Remote system Information IWCESUL Ah Remote Zoomin WICES500 select Remote Tools k Customize ptons ta Macro Record Qvick Macro tirs huft E Play Quick Macro Ltl Shitt P configure Platform Manager WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 108 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 2 In the Option dialog select the Directories tab and do the following in this order to specify the header file include path The specified include path of the header file is default located at C Program Files Windows CE Toolswce500 PAC270McpdasWMncludeARMVATN Options E Download H fd Directories kspace Macros Format CPUs show 25204070 Include files 2 Win32 CE ARMY AI P
117. t the options that 64 bit Searial Nunber 01 40 65 04 11 00 00 71 you want to backup OS Yersion 1 5 0 2 CPU Version 1 0 1 0 enter text annotations BP Version 1 0 1 0 and then click the Start 1 address 0D D0 3F 01 A5 64 2 5 00 00 10 71 00 backup button aAnnatbatbian Backup by ICP DAS WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 53 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 4 Confirm the backup options and then click Yes button Browse for Folder Network z System Disk Micra SD z Recycled Application Data My Documents Program Files profiles Cancel Step 6 Wait for process to finish WinPAC 8000 User Manual version 2 0 5 Copyright 2009 ICP DAS Co Ltd All Rights Reserved Total number of backup items 3 Are you sure you want to backup there items Eboot and OS Need 32M6 af space Registry Step 5 Choose the folder that you want to save backup file and click the Ok button Ackup Utility Backup Restore Help Backup SRAM Backup the System Disk ok b 3 Compressing the OS and eboot file need 2 mint Compressing System_Disk need 1 minutes Compressing the backup file WSB_DiskiBackup 2010 04 06 11 06 zip Compression is finish Backuping is finish lt Last Revised February 2011 Page 54 E mail
118. tains two Ethernet ports for use with network devices and are denoted as LAN1 and LAN2 WP 8441 AWP 8841 WP 8431 WP 8831 Each Ethernet port has two LED indicators which are used to indicate the network speed and Link Acting as described below LED Indicator State Color Meaning 10 100 Network Speed 100 MB Network Speed 10 MB Link Act ON Green The Link is active The Link is inactive Blinking Green Network activity WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 28 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 8 USB Port The WinPAC contains 1 2 USB port s that allow support for USB devices such as mouse keyboard or an external USB hard drive WP 844 1 WVP 884 1 WP 8431 AWP 8831 USB Port 9 COM1 Port Type Female Baud Rate 115200 57600 38400 19200 9600 4800 2400 1200 bps Data Bits 7 8 Parity None Even Odd Stop Bits 1 FIFO 1 byte WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 29 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 10 RS 232 RS 485 Port Type Male Baud Rate 115200 57600 38400 19200 9600 4800 2400 1200 bps Data Bits 5 6 7 8 Parity None Even Odd Mark Always 1 Space Always 0 can be configured as either RS 232 or RS 485 but only one Data mode ca
119. te apetece Te Dan aene tede 86 4 4 1 Create a new project 86 4 4 2 Add project reference for an application 88 4 4 3 Design and Build an application program 89 4 4 4 Execute the application on the WinPAQC 92 4 5 Your First Program in VB net 94 A SN Grede ANEW 94 4 5 2 Add project reference for an application 96 4 5 3 Design and Build an application program 97 4 5 4 Execute the application on the WinPAC 3 2 8 9 99 2925 100 4 6 Your First Program in eMbedded Visual 102 4 6 1 Create new Forms Based dem E EE 102 4 6 2 Configure compiler Options v s ooo o oerte tee e e acces 107 4 6 3 Specify the path for project 108 4 6 4 Design and Build an application program 112 4 6 5 Execute the application program on WINPAC 116 5 APIS and Demo References 117 SM MM BEMO programs WII OH 118 5 1 1 C Demo programs for WinPAC Standard AP 1
120. ter via USB 191 E o HOW TOJ3ISS SCIVICOS haa a I ESO 192 Appendix F Revision History 195 1 Introduction Experience new PAC technology Maximize business Win DAC 8000 the most powerful control systems lj mr me M gt au Ei gt WinPAC 8000 is the second generation of ICPDAS It equips a PXA270 CPU 520 MHz running a Windows CE NET 5 0 operating system various connections VGA USB Ethernet RS 232 485 and 1 4 8 slots for high performance parallel I O modules high profile 8K series and serial type I O modules high profile I 87K modules Its operating system Windows CE 5 0 has many advantages including hard real time capability small core size fast boot speed interrupt handling at a deeper level achievable deterministic control and low cost Using Windows CE Net 5 0 in the WinPAC 8000 gives it the ability to run PC based Control software such as Visual Basic NET Visual CZ Embedded Visual SCADA software Soft PLC etc Comparing with the first generation WinCon 8000 it not only improves the CPU performance from 206 MHz to 520 MHz and upgrading OS from CE 4 1 to CE 5 0 but also adds many reliability features such as dual LAN redundant power input dual battery backup SRAM etc It gives you all of the best features of both traditional PLCs
121. the Project menu E Ele Edit View Insert Project Build Tools Window Help set Active Froject k Add To Project k Dependencies Export Makefile Insert Project ito Workspace Step 5 In the Project Settings dialog box do the following in this order Project Settings Settings For Win32 CE ARMVAI Release Output file name ARMVAIRellsysteminfo exe Generate debug info Ignore all default libraries Generate mapfile Project Options nologo fbase 0x00010000 stack 0 10000 0 1000 leny w rinMainCHT Startup fincremental no Ipdb ARMVAIBel systeminfo pdb camel WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 111 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 6 4 Design and Build an application program Step 1 On the Workspace window select the ResourceView tab and expand the dialog folder and then double click the IDD DEMO DIALOG to open the dialog box x Ela 4 2 ClassView aes HesnurceView amp FileView Step 2 Add the button object in the systeminfo dialog box SDKinfo rc IDD SDEINFO DIALOG German Germany Dial E 5 k HE Aa abl 1 x EB EE m t E Buttoni EF ZU ERLED Dialogfeld Steuerelem hier Last Revised February 2011 Page 112 WinPAC 8000 User Manual version 2 0 5 E mai
122. x that install on PC SDK SDKs related to WP 8x3x WP 8x4x System_Disk Tools and drivers related to System Disk that install on WP 8x3x WP 8x4x Update Installation packages related to WP 8x3x WP 8x4x updates WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 Page 31 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 1 6 Comparison of WinPAC and WinCon WP 8x3x WP 8x4x WP 8x3x WP 8x4x is the second generation of PAC It is equipped with various connections VGA USB Ethernet RS 232 485 and 1 4 8 slots for high performance parallel modules high profile I 8K series and serial type I O modules high profile 87 I O modules Comparing to the first generation WinCon it not only improves the CPU performance from 206 MHz to 520 MHz but also add many reliability features COM3 RS 232 RS 485 Operating Modes Selector Dual Battery Backup SRAM COM4 1 RS 232 Power Indicator Micor SD socket di T PA LI WP 8831 Na B J m COM1 VGA m aes 5 232 Analog Input Output DIP Switch 61 0 Slots Digital Input Output Motion Timer Counter Redundant Power Fi 10 30Vo0 m USB Port 2 Relay Output L Ethernet Port 2 COM2 RS 485 i Ze USE Port 1 Frame Ground Ethernet Port 1 WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 32 Copyright 2009 ICP DAS Co Ltd
123. y 2011 174 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 3 On the Project menu click Project Name Properties command File Edit View Evld Debug Format Toole Window Community Help Add Windows Form Bj Add User Control i Add Component vig Add Class Shift Alec Add New Item Add Existing Shaft Alte A Exclude From Project show All Files Add Reference Add Web Reference met as start p Change Target Platform Swstemlnfo Properties Step 4 On the Systemlnfo tab unselect Deploy the latest version of the NET compact Framework including Service Packs check box _ ereate_database Form cs Fonnlcs Design Object Browser Configuration Platform Build plowment Options Build Events Target device Debug PACSO ARMY4 AEMVAI Release Jutput file folder CSIDL_PROGRAM FILES icreate_database Reference Paths Deploy the latest version of the NET Compact Framework including Service Packs 1 Siening thenticode Signing Sign the project output with this certificate Devices select Cer WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 175 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 5 On the Tools menu click Options
124. y Makes a back up of a registry sub key How to use Step 1 Select the Export Registry Key then the Export Registry box will appear otep 2 Select a specific root key otep 3 Input a specific path of sub key otep 4 Push the OK button then the Save As dialog box will appear prompting you to select a location where you want to save this exported file Warning The export operation will export all the sub keys of the specific key which you input Store All Registry otores all registry setting to flash from das file which oetting is saved by Dump All Registry Setting How to use WinPAC User 8000 Manual version 2 0 5 Last Revised February 2011 67 Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com The menu commands Use to Step 1 Select the Store All Registry Setting then the Open dialog box will appear Step 2 On the Open dialog box select a specific das file to store Warning 1 The das file which should be saved by Dump Registry Setting 2 It will save automatically after store das file Dump All Registry Dump all registries setting to das file Settings How to use Select the Dump All Registry Setting then the Save As dialog box will appear prompting you to select a location where you want to save this exported file WinPAC 8000 User Manual version 2 0 5 Last Revised February 2011 Page 68 Copyright

Download Pdf Manuals

image

Related Search

Related Contents

Meeting Rooms User Manual  DW721 DW722 DW725 DW726 - Service après vente    Add-On Computer Peripherals (ACP) SFP-SX-AU-AO network transceiver module  防火区画貫通部措置製品 (PDF 3726KB)  IQBoard ET & PS V7.0 User Manual  Product User Manual - Gerling Applied Engineering, Inc.  T-336Cx/Nx/NDx User Manual  料理をおいしく、キッチンをきれいに。 クリステルなら毎日が快適  Philips Multimedia Speakers 2.0 SPA7210R  