1. LHP S Traffic Light Controller Uninterruptible Power Supply Pure Sinewave Line Interactive UPS Digital with Microprocessor Control Advanced LCD Control Panel A Multi Functional Outdoor UPS Long Back Up to Support Traffic Application Applicable for Traffic Lights amp Controllers Designed to Operate Under Harsh environment Built in Solar Cooling Fan Saves Power in Extreme Temperatures Protection against Lightings Surges Disturbances Blackouts etc Available with Gel Batteries with 10 Years Life Expectancy True RS 232 Communication Interface EEC 9160 Traffic Signal Controller Uninterruptible Power Supply PowerBank EEC 9160 system the first traffic signal controller UPS in Taiwan is designed to provide emergency power back up support at critical intersection to enhance public safety and improve signal controller reliability EEC 9160 provides power under very tough and harsh outdoor environment With the fully controlled microprocessor it assures flawless operation on reducing equipment failures maintenance cost and prolonging life of traffic signal controller Intersections with high speed traffic emergency evacuation routed potential hazardous EEC 9160 is your ideal solution Traffic Signal Controller UPS T S C UPS is consists of two major parts which including UPS system and Battery system UPS system Battery system UPS SYSTEM 1 Front Face A
2. Input Breaker H LED Display B Battery Breaker I LCD Display C Output Breaker J UPS Manual Bypass Switch D Maintenance Manual Bypass Switch K AC Switch E Buzzer Alarm L LCD Menu Selector up Protective Fuse for Maintenance Socket M LCD Menu Selector down G Maintenance AC Socket N Alarm Switch 2 Back Face a L amp N reverse warning LED d Battery Input Bolt g AC Power failure Signal Terminal b Generator Input Bolt e AC Output Bolt h AC Input Bolt c RS 232 Interface f Cooling Fan 1 Input Breaker 3 Side Face I Generator Input Bolt Buzzer Switch e The UPS switching efficiency not less than 85 leakage current less than 3 5mA RMS eOver 80db buzzer warning to safeguard UPS against provoked opening of the cabinet door eL amp N reverse LED warning Battery System Battery Bracket GEL VRLA Battery eHot Swappable Battery System assures no disruption of the traffic signal would occur during removing the UPS or battery for maintenance ewell mounted battery brackets provide enough space for batteries eMTTR Mean Time to Replace or Repair shall not exceed 5 min Cabinet Design a 2 3mm zinc coated steel cabinet with super durability is the very design for harsh outdoor environment b Four lifting rings on top of the cabinet for easy handling after equipped Solar Cooling Fan can provide a maximum revolving speed of 1200RPM Min Machinery Shocking Test 1 Te
3. ing battery symbol when the UPS is in testing mode Buck mode The AVR Auto Voltage Regulator is reducing the output voltage of the UPS when the input voltage is too high and the sine wave symbol as mentioned in item 4 will also display steadily to indicate that the output is in the normal mode The AVR is increasing the output voltage of the UPS when the input voltage is too low and the sine wave symbol as mentioned in item 4 will display to indicate it s the normal mode Timer is This symbol will show up in the following situations enabled 1 A turn on turm off schedule has been set using the monitoring software Refer to User s Manual 5 6 and the Readme file or Help function of the monitoring software 2 The Green Mode is enabled and the loading is under 25W approximately The UPS will turn itself off automatically in 30 seconds Refer to 4 3 of User s Manual The temperature inside the UPS is over 55 If the user does not reduce the load the temperature will continue to rise and the UPS will shut down automatically at 60 C is This symbol is used only for long run series and the 5000VA model High speed The symbol will display whenever the cooling fan is running in high speed and will disappear at low speed 10 Silence The audible alarm has been silenced reset the alarm mode Back up mode push the control button not available during low ba
4. sting Equipment Ling Electronics 612 Vibration Machine DACTRON LASER shaker system controller 2 Testing Environment Temperature 24 28 Relative Humidity 52 60 3 Testing Condition Impact Load 30G Time of Impulse 11 ms Three times per surface 4 Testing Results No degradation of performance existed after testing Remarks Data of Machinery Shocking Test are provided by Electronics Research amp Service Organization of Industrial Technology Research Institute Taiwan LCD DISPLAY Load level Mode amp value Battery level J im meon Ql 3 SELF TEST ALARM RESET 4 P Se Main Control Button LCD Screen Selection Button for Mode amp Value Symbol neon KS Over load The loading exceeds the rating of UPS HS Load level The higher the loading the more bars will illuminate UPS is When Green Mode is enabled this symbol will display if the loading is over loaded 30W approximately and disappears when it s under 25W approximately Please refer to User s Manual 4 3 If Green Mode is disabled the symbol will always display 4 Normal 1 The sine wave symbol will display steadily without battery symbol mode when UPS is in the normal mode 2 The sine wave symbol and battery symbol will blink when the mode UPS is in back up inverter mode a Test mode 3 The sine wave symbol will display steadily with blink
5. ttery level or abnormal condition 11 UPS fault The UPS has failed and must be repaired Contact a qualified service person 1 In normal operation this symbol indicates a charged battery 2 When the battery charge level is low the word LOW will be added to the symbol replacement checked each time the Test Function is executed 13 Battery The battery has failed and must be replaced The battery is 14 H 1 The higher the battery voltage the more bars will illuminate a 2 When the UPS is charging the battery the battery symbol and the level indicator will blink together 15 Mode Value Deseripton ACout output voltage 00000000 AC input voltage 0 00000000000 ACout Hz AC output frequency 0 0000000 BATT DC battery voltage eee Min to off The UPS will turn off when the displayed value reaches zero For example if the timer shows 0 5 Min to off the UPS will shut down in 30 seconds TIMER Hr to on The UPS will turn on when the displayed value reaches zero For example if the timer shows 48 Hr to on the UPS will turn on in 2 days BATT Min to off The estimated remaining run time in Back up mode The accuracy of the value is influenced by the loading type ambient temperature and battery condition old or new selection Button for mode amp value All the operation data will be displayed on LCD screen By selecting the req
6. uired mode upward or downward the related value will be displayed

Download Pdf Manuals

image

Related Search

Related Contents

HP Deskjet D1560 User's Manual  OUTDOOR WIRELESS SIREN  CLIPSTER Edit Tool User Guide (Version 1.4)  Manual de instalación para SimonVOX.2  User's Manual SP200F SERIES - i  D-Link DSL-2750B router  Transition Networks SBFTF1011-120 User's Manual  Built-In Electric Oven User Manual  Livret de compétences de l`élève en ULIS 2011  Untitled - 広島ガス高田販売  