User`s Manual - INHECO Industrial Heating & Cooling GmbH
Contents
1. 7 INHECO GmbH Annex Plate 384 Pos PCR 11 Plate 96 Pos PCR 11 Plate Multi Purpose 10 Safety 7 Safety instructions for operation 12 Scope of 9 lupe 8 Shut down and Disposal 8 Technical 7 Technical 15 Ventilation 12 20
2. 2 0 cceccceeccecceecceeccecceecceecceseeacceeceaseeaecesseeseeaseeeseuseeaeeeeseesens 19 ANNEX B INDEX OF ILLUSTRATIONS 0 0ccceecceeccecceecceeccecceecceecceeceaceesceeseeaeeeseceseeeeeeeseesens 19 ANNEX C INDEX OF TABLES osccovzcoveosecoezase vuze duvaczz ocuu 19 ANNEX D INDEX 1 2 20 INHECO GmbH Explanation of Symbols 1 Explanation of Symbols A possible danger leading to serious bodily harm is being pointed out to you Caution hot surface A possible danger leading to less serious bodily harm is being pointed out to you This signal also warns you of tangible damage A possible dangerous situation leading to material damage is being pointed out to you Important D This sign refers to useful information as to installation etc e Bullet points refer to enumeration gt These arrows are intended to give instructions These squares refer to procedures which run automatically and results which should be achieved INHECO GmbH INHECO GmbH Safety Instructions 2 Safety Instructions Technical Changes e For safety reasons no technical changes to this unit are allowed Any modification or change which is not approved by the manufacturer leads to loss of guaranty e The original parts are designed especially for the MTC Parts provided by other suppliers are not tested and therefore not approved by INHECO
3. ethylene oxide gas The surface decontamination can include a wipe down of the housing surface A solution of 7096 alcohol should be used where effective for target organisms It is recommended that the CPAC is left running during decontamination and is running for at least 5 minutes in order to purge the atmosphere inside before it is switched off Make sure that no moisture enters inner parts Calibration For proper thermal performance of the MTC Unit and the connected devices it is recommended to check the calibration once a year Depending on the application shorter calibration intervals may be required This job has to be done by authorized service stuff only or at the INHECO service center Munich Germany Spare Parts Spare Parts for the device must be ordered by INHECO Only original parts from INHECO may be used 16 INHECO GmbH 6 Technical Data supply voltage maximum power input temperature range plate temperature range ambient transportation and storage conditions max reachable temperature difference in the heating mode max reachable temperature difference in the cooling mode sensor type LxWxH of basic version weight including cord maximum admissible relative atmospheric moisture temperature cycling CPAC steady state CPAC Table 1 Technical Data Technical Data 12Vdc 7000179 7000195 24Vdc 7000163 60W 7000179 7000195 113W 7000163 4 to 70 C 39 to 158 F 7
4. 000179 4 to 90 C 39 to 194 F 7000195 4 to 110 C 39 to 230 F 7000163 15 C to 32 C 10 C to 60 C non condensing 14 0 F to 140 F up to 80K up to 30K two PT100 128mmx89mmx103mm 7000179 128mmx89mmx103mm 7000195 128mmx89mmx1 13mm 7000163 approx 1 0 kg 8096 non condensing On request 7000179 7000195 7000163 depends on the used adapter plates and disposables 17 Declaration of Conformity 7 Declaration of Conformity INHECO GmbH Fraunhoferstr 11 82152 Martinsried Germany Declares that the following product CPAC Microplate HT meets the essential requirements of the following European Union Directive s using the relevant section s of the normalized standards and related documents shown Standard and Date of Issue IEC 61010 1 2001 2 Edition EN 61010 1 2001 2 Edition Safety requirement for electrical equipment for measurement control and laboratory use EN 61010 2 010 2004 Particular requirements for laboratory equipment for the heating of materials EN 61000 3 2 EN 61000 3 3 Electrical equipment for measurement control and laboratory use EMC requirements EN 61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements This product is in complies with the essential requirements of the Low Voltage Directive 73 23 EWG and EMC directive 2004 108 EC when us
5. GmbH Using them can lead to the impairment of the functionality of the unit e For damages which may occur due to the usage of non original parts liability is excluded by INHECO GmbH Burn Hazard You can burn your skin when touching the inner parts and especially contact surface and disposables These parts can reach up to 50 122 F Do not use materials that are not sufficiently temperature resistant up to 110 C 230 Use in Biosafety Laboratory Environment When using the Thermoshake in a Biosafety Laboratory Environment the user of the Thermoshake is responsible for labeling the device according to the WHO Laboratory Biosafety Manual ISBN 92 4154650 6 The user is furthermore responsible for operating the Thermoshake depending on the biosafety level regulations according the WHO Laboratory Biosafety Manual The safety regulations valid for the lab are to be constantly observed when working with the device Malfunctions Report occurring malfunctions immediately to the responsible person sure the unit is secured against violation and misuse Dismantled safety relevant parts have to be mounted and checked before initial operation Name Plate and Labels Please observe all name plates and labels and make sure to maintain their legibility Replace all name plates and labels if their legibility is no longer ensured INHECO GmbH Safety Instructions Conventional Usage The CPAC Microp
6. PAC Microplate No service is necessary for this unit Therefore no inspection is needed Shut Down and Disposal The unit is to be disposed according to the effective environmental directives Safety instructions in case of contamination have to be preserved The Thermoshake is RoHS and WEEE compliant Initial Operation 3 Initial Operation Scope of Supply Before initial operation make sure that shipment was complete and no part had been damaged These components should be included in each shipment e Tempering Unit CPAC Microplate Integrated mounting flange Patch cord with connector e Mounting frame for PCR adapter plate 4 mounting screws e User s Manual on USB stick not shown on the picture below tu Fig 1 Scope of Supply Basic Version The CPAC Microplate tempering unit matches INHECO s MTC STC perfectly The special MTC settings for the CPAC Microplate are listed on page 15 INHECO GmbH 10 INHECO GmbH Initial Operation Additional Options Controller Multi Tec Control MTC and Single Tec Control STC e Comfortable Plug amp Play MTC Adapter Plates Plate Flat Bottom A ay e Adapter Plate for Tempering of Microplates with Flat Bottom e Reproducible Positioning of Plates by Spring System Initial Operation Plate Multi Purpose Universal Adapter for Divers Applications Plate 96 pos PCR 29999099 9999090999 29990006 990009006 Adapter for the Tempering of 96 Pos PCR Pla
7. ed for its intended purpose Place Martinsried Munich Date March 2009 Signature Name Gunter Tenzler Managing Director Position INHECO GmbH INHECO GmbH Annex Annex A Index of Acronyms Acronyms Explanation Degree Celsius B W Width H Height Hz Hertz 1 5 lac Alternating Current Direct Current Kelvin Kilogram Length Proportional Integral Derivative Function of TEC Control TEC Thermo Electric Cooler Thermoelectric Module Udc Direct Voltage W Watt Table 2 Index of Acronyms Annex B Index of Illustrations Fig 1 Scope of Supply Basic Version 10 Fig 2 Ventilation Openings 14 Annex C Index of Tables Table 7 Technical Data 17 Table 9 Index of Acronyms 19 19 Annex D Index Additional 10 5 13 Declaration of Conformity 16 Explanation of symbols 6 Index of Acronyms 17 Index of Illustrations 17 Index of 17 Initial 9 Malfunctions eseee 7 Meaning of this 4 Mounting 9 Name Plate and
8. inheco CPAC Microplate Part No 7000163 7000179 7000195 Heating and Cooling Unit User s Manual January 2010 Uncontrolled when printed or transmitted electronically Doc ID 900003 000 Printed in Germany INHECO GmbH CPAC Microplate INHECO GmbH reserves the right to modify their products in order to improve their quality These modifications do not have to be documented as a rule This manual and the information herein have been assembled with the necessary diligence INHECO GmbH does not assume liability for misprint or damages caused by misprint The brand and product names within this manual are registered trade marks and belong to the titleholders respectively INHECO GmbH Contact INHECO GmbH Fraunhoferstr 11 82152 Martinsried Germany Telephone Sales Telephone Technical Hotline Fax E Mail Sales E mail Technical Hotline Website This manual belongs to Type Serial No Year of manufacture Order No To be filled in by customer Inventory No Place of installation 089 899593 101 089 899593 201 089 899593 499 sales inheco com techhotline inheco com www inheco com PRODUCT SERVICE Contact INHECO GmbH CPAC Microplate Meaning of this Manual This manual is part of the CPAC Microplate and must be e retained until the CPAC Microplate is disposed e passed on when the CPAC Microplate is sold or lent Please contact the manufacturer in case you d
9. late meets the current technical level and complies with today s standards The manufacturer attached much importance to the user s safety The following rules obtain to the user e Rules of accident prevention e General rules for technical safety e EU and other country specific directives The conventional usage contains the usage according to the user s manual This unit is to be used only in non precipitating and dry environment The CPAC device is designed for the usage in Life Science and IVD in vitro diagnostic environments The CPAC device is prepared for an easy integration into IVD applications but the final IVD validation has to be performed by the first marketer You must able to disconnect the main power supply the unit immediately if necessary Explosive flammable and volatile materials may not be heated in the CPAC Microplate The unit may not be operated in rooms at risk of explosions The CPAC Microplate may only be operated in an upright position The CPAC Microplates are optimized maintaining a constant temperature in the disposable and thermal cycling see chapter Technical Data It should be ascertained that no liquids penetrate into the unit The CPAC Microplate unit may not be stored below 10 Who is Permitted to Operate this Unit Only instructed and skilled personnel are permitted to operate this unit Only specialized staff is allowed to make any amendments of the operating menu Service of C
10. o not understand something within this manual Your opinion on this manual provides us with valuable insights on how we can serve you better Please do not hesitate to direct your comments to us at the address or the phone numbers on page 3 The safety instructions must be read very carefully They must be understood and observed in order to ensure a safe handling Missing or insufficient knowledge of the manual leads to loss of liability against INHECO GmbH The operator should therefore ask for an instruction confirmation from the manufacturer Content Content 1 EXPLANATION OF 9 7 2 SAFETY INSTRUCTIONS 11 5 2 22 22 22 edad 0022 ea ooa oia cca cosa aora aou as 8 3 INITIAL nh mena sacra ssa 10 4 MTC ADJUSTMENT 1 33226 od ve aus aaa oU sk ea ausa cU sk caa seno 15 5 USER MAINTENANCE 22 22205222222 212c 2527255702275 caca o ana cara non asa cona naa caua cara Dona nara c anna aaea 16 6 DAT A c DEE 17 7 DECLARATION OF CONFORMITY 18 ANNEX A INDEX OF ACRONYMSG
11. tes 06062 Plate 384 pos PCR Adapter for the Tempering of 384 Pos PCR Plates 12 INHECO GmbH INHECO GmbH Initial Operation Tube Rack 24x1 5ml 7900015 e Adapter for the Tempering of Standard Reaction Tubes of 1 5ml for example Eppendorf make e Other adapter plates are available on request Please contact INHECO More detailed information about reachable temperature differences temperature uniformities heating and cooling rates on request 13 INHECO GmbH Initial Operation Safety Instructions for Operation To avoid injuries and damage an unimpeded air supply must be ensured The maximum ambient temperature must not be exceeded in order to prevent the CPAC Microplate from damage Also see the technical data on page 16 You can burn your skin when the contact surface heat sink and disposables These parts can reach up to 50 122 F Do not use materials that are not sufficiently temperature resistant up to 110 C 230 F An unimpeded air supply must be ensured to avoid injuries to persons and or damage to the unit Do not operate the CPAC Microplate above the maximum ambient temperature to prevent the CPAC Microplate from damage Ensure that there is a minimum of at least 25 cm 10 inches free space at the ventilation openings Ventilation Openings Fig 2 Ventilation Openings 14 INHECO GmbH MTC Adjustment 4 MTC Adjustment For the precise procedure please refer
12. to the MTC Control user s manual The adjustment of the PID parameters has been done for the CPAC Microplate basic version Depending on the optional attachment for example plate 96 pos PCR a new adjustment of the PID parameters may be necessary in order to achieve an optimized result Information about the adjustment of the PID parameters can be found in the MTC manual If you need any assistance please contact us 15 INHECO GmbH User Maintenance 5 User Maintenance Cleaning Before cleaning the CPAC Microplate disconnect the power and make sure that the temperature at the contact surface is below 50 122 F The contact surface anodized aluminum should be cleaned regularly to ensure optimum heat transfer to the disposables Always clean the contact surface if there has been a spillage Use a cloth dipped in 50 50 water isopropanol solution and make sure that no deposits are left on the surface Care should be exercised to prevent water from running inside the unit The plastic frame of the CPAC Microplate can be cleaned with a cloth dipped in water or methanol No part of the body should be immersed in the solvents Do not use aggressive cleaning fluids such as acetone or abrasive cleaners Please check with INHECO any cleaning method that is not mentioned in this paragraph to prevent damage to the CPAC Microplate Decontamination The most common decontamination method is by fumigation with formaldehyde or