1. OT Courant de soudage continu Welding direct current Gleichschwei strom La corriente de solda dura es continua Ha Alimentation lectrique triphas e 50Hz Three phase power supply 50 Hz Dreiphasige Netzversor gung mit 50 Hz Alimentacion el ctrica monofasica 50 Hz Tpexcba3Hoe 50 Tension assignee vide Rated no load voltage Leerlaufspannung Tension asignada de Tension assign e d alimentation rated supply voltage Netzspannung Tension de la red Courant d alimentation assigne maximal valeur efficace Rated maximum supply current effective value Maximaler Versorgungsstrom Effektivwert Corriente m xima de alimentaci n de la red Courant d alimentation effectif maximal Maximum effective supply current Maximaler tats chlicher Versorgungsstrom Corriente de alimentaci n efectiva maxima EN60 974 1 Lappareil respecte la norme 60974 1 The device complies with EN60974 1 standard relative to we
2. Clean or replace ad wire unwinding x Reel brake too tight Release the brake See the branch connection and look if Bad connection to the main supply the plug is fed by 3 phases Control the earth cable connection and clamp condition Power contactor inoperative Control the torch trigger Covering wire guide crushed Check the covering and torch body Locking of the wire in the torch Clean or replace The wire rubs down after the rollers No capillary tube Check the presence of capillary tube Wire speed too fast Reduce the wire speed The gas flow rate is not sufficient NSW dr Clean the working metal Gas bottle empty Replace it Gas quality non satisfying Replace it Air flow or wind influence Avert air blast protect welding area The welding cord is porous Gas nozzle too full Clean or replace the gas nozzle Use adapted WIRE for MIG MAG Bad wire quality welding Surface to weld in bad condtion rust Clean the working parts before etc welding Arc voltage too low or too high See welding settings Very important flashing particules Bad earth connection Cari Ze have a better connection Protecting gas insufficient Adjust the gas flow See ifthe gas coupling beside the No gas at the torch output Bad gas connection engine is well connected Check the flowmeter and the solenoid valves No welding current Bad earth connection 13 TRIMIG SCHEMA ELECTRIQUE
3. ft X 25 26 x x xx zal LLLLEEEETIE x 129 30 x 34 TRIMIG Trimic 350 45 DUO DV 230 400V CARTE MICRO CARTE MOTEUR 51915 commande devidoir 35 TRIMIG Trimic 350 DV 230 400V CARTE MICRO CARTE MOTEUR KEY EDA RD connecteur commande devices s par 36 TRIMIG 5 DETACHEES SPARE PARTS ERSATZTEILE PIEZAS DE RECAMBIO 200 45 250 45 DV 300 4S 300 G 350 4S DUO DV 350 DV Rz 300 G 350 DV ri AAAA Trimic 300 G 350 45 DUO DV Trimic 350 G DV 37 TRIMIG 7 17 LA 2 de 80cm 80cm chain 80cm Sicherungskette cadena de 80cm 80 Support c bles arriere Rear cable support Hinterer Brennerhalter Soporte trasero de cables Support torches avant Front torches support Vorderer Brennerhalter Soporte antorchas delanteras Poignee Handle Griff Bouton reglage de vitesse fil Wire speed adjusting knob Poti Drahtvorschubgeschwindigkeit Bot
4. Rad 200mm Durchmesser Rueda diametro 200mm Koneco 200 MM Embout End axis Radachse Boquilla de pasador Ocb Contacteur 24V AC 10A Contactor 24V AC 10A 24V AC 10 Schalter Contactor 24V AC 10 24B AC 10A Transformateur de commande Control transformer Steuertransformator Transformador de mando Electrovanne Solenoid valve Elektroventil Electro valvula 73099 51916 51915 52461 7 pos 10 pos 12 pos 7 pos 51054 51072 51074 51227 2 pos 51071 51136 51257 21475 21497 21470 71603 71361 71364 52190 52173 52174 52221 96076 96079 96081 96083 52101 96075 96078 96080 96082 51006 71375 71376 71382 51114 51107 92994 96029 96047 96029 71512 8 TRIMIG Carte de commande Control card Steuerkarte Carta 97132 97172 de mando Carte d affichage Display card Anzeigekarte Carta de 97183 97233C fijacion 27 Tuyau gaz 1m Gas pipe 1m Gasschlauch 1m 95993 Tubo del gas 1m 1 Collier 10 5 Collar 10 5 Schlauchschelle 10 5 Collar Ss 10 5 10 5 71225 Connecteur 1 4 cable de masse Earth cable connector 1 4 Texasbuchse 1 4 Leistungsanschlus
5. CIRCUIT DIAGRAM SCHALTPLAN DIAGRAMA ELECTRICO Tr m s 200 45 LdHIYOL wf JON VSSINd WO Wika 12 Lg CS Hain SITE 44 1 USORTIE ZU WHOWHSHL LNI LA E 942101 31 71512 gt lt ASII l A d A f 2 s rl D A 51136 Kuu oot ac Se ET 1 IH USORTIE USORTIE 9 2 3 j g Ge 5 a D m x GL 1 z KEYBOARD 32 TRIMIG Tr m s 300 45 KEYBOARD 4 53101 ALa 715129 1 J Ad H H TES p i i i I I I 2930 11 a Ix lx xix x x x 33 TRIMIG 300 G KEYBOARD 53101 connecteur commande dewidoir s par HRF ale 78 91011 12 PT 56 x RCE ELL swf III DL gia txt 1516 DOIT ive L Le 21 22 x x x xx L
6. Wire feeder control cable connector 17 Wire feeder power cable connector 18 Selection switch potentiometer only on 300G and 350 G DV SEMI AUTOMATIC WELDING FOR STEEL STAINLESS STEEL MAG MODE FIG III Trimig 200 45 can weld 0 6 0 8 1 steel and stainless steel wires fig III A The device is capable of working with 1 0 mm steel wire roller 0 8 1 0 contact tip of 01 0 If using lower diameter wire you should use change the contact tip and ensure that the reversible rollers in the wire feeder are positioned correctly so that required diameter is visible when in place Trimig 250 45 DV 230 400V can weld 0 8 1 1 2mm steel and stainless steel wires The device is capable of working with 1mm steel wire roller 2 0 8 1 0 contact tip of 1 The Trimig 300 45 300 G 350 45 DUO DV and 350 G DV can weld 0 8 1 1 2mm steel and stainless steel wires The device is capable of working with 1mm steel wire roller 1 0 1 2 contact tip of 1 For Steel or Stainless Steel you will need to use specific gas Argon CO2 Ar CO2 The proportion of CO2 will vary depending on usage The gas flow for steel is between 10 and 20L min depending on the environment and experience of the welder SEMI AUTOMATIC WELDING FOR ALUMINIUM MIG MODE FIG III The Trimig 200 45 can weld 0 8mm imm aluminium wires fig III B Trimig 250 300 and 350 can weld 1mm and 1 2mm aluminium wires fig III B To wel
7. entspricht europ ischen Richtlinien El aparato esta conforme a las normas europeas Conforme aux normes GOST Russie Conform to standards GOST Russia in be reinstimmung mit der Norm GOST PCT Conforme a la normas GOST Rusia L arc lectrique produit des rayons dangereux pour les yeux et la peau protegez vous elec tric arc produces dangerous rays for eyes and skin protect yourself Der elektrische Lichtbogen verursacht Strahlungen auf Augen und Haut Sch tzen Sie sich El arco produce rayos peligrosos para los ojos la piel i Protejase Attention souder peut declencher un feu ou une explosion Caution welding can produce fire or explosion Achtung Schwei en kann Feuer oder Explosion verursachen Cuidado soldar puede iniciar un fuego una explosi n CBapka Attention Lire le manuel d instruction avant utilisation Caution Read the user manual Achtung Lesen Sie die Betriebsanleitung Cui
8. 16A or 32A plug type EEC RS 015 They should be plugged in to a 400V 3PH power socket WITH earth and protected by 16 circuit breaker and 1 differential 30mA 230V 3 phase power supply for 250 45 DV 350 G DV and 350 45 DUO DV WARNING This device is pre built in 400V three phase If your electrical installation is 230V three phase you must modify the connection on the terminal board This modification must be undertaken by qualified personnel In order to do so please refer to the technical diagram inside the product The plug must be protected by a 16A or 25A for models 350 circuit breaker and 1 differential 30mA DEVICE PRESENTATION FIG II 1 On Off switch 8 Earth cable connector 2 Power Settings 2 switches with 7 positions for ad justment of the welding voltage output The adjustment of the output voltage is proportional to the thickness of 9 Gas bottle support max 1 bottle of 10m3 10 Fastening chain for bottles Warning fasten the chain securely see IV 1 the work piece 3 Control panel Welding settings manual or automatic mode 4 European standard torch connection 5 Thermal Protection light Indicates when a cool down period is necessary following intensive use 6 Torch support 7 Power Cable 5m 11 Reel support 200 mm 300mm 12 Gas connector 350 45 DUO DV 13 Torch Cable support 14 Wire feeder solenoid valve 2 15 Wire feeder gas connection for torch 2 16
9. Position the potentiometer 4 in the middle of the SPOT Spot welding with adjustable spot diameter OPTIMAL SYNERGIC zone Wire speed selection 4 In this mode the device determines the optimum wire Wire speed regulator speed according to 3 parameters The speed varies from 1 to 15 m minute Voltage Wire diameter SPOT DELAY setting potentiometer 5 The power mode It is possible to adjust the speed wire Manual Mode 1 In manual mode the wire speed is determined by the user by adjusting the potentiometer 4 10 TRIMIG MANUAL MODE FIG V To set your device proceed as follows Choose the welding voltage using the 2 power switches 2 and 7 positions Example For welding Steel 1 mm with a 0 0 8 wire set the switch to 1 Adjust the wire speed with potentiometer 4 Advice The wire speed adjustment is often determined by the noise the arc must be stable and emit low crackling If the speed is too low the arc will not be continuous If the speed is too high the arc crackles and the wire will push back the torch SYNERGIC MODE FIG V This function automatically controls the wire speed There is no need to set the wire speed manually e Position the wire speed potentiometer 4 in the middle of the Optimal synergic zone e Select Wire type 3 Wire diameter 3 Power setting switch on the front To select the right position accordance with the thickness of th
10. TRIMIG TRIMIG TRIMIG www gys fr 73502 V4 03 09 13 II 200 4S 250 4S DV 300 4S Acier Steel Stahl Acero Staal Aco Inox Stainless steel TRIMIG 300 350 W WA A TRIMIG 250 300 350 Gi Ss elo MIG MADE IN FRANCE LS EASY CONTROL 4 4 TRIMIG DESCRIPTION Thank you for choosing this product please read this instruction manual carefully before installing and using the product and keep in a safe place for future reference The Trimig are semi automatic welding units they are ventilated for semi automatic welding MIG or MAG and are capable of welding steel stainless steel and aluminium Adjustment is quick and easy with their synergic wire speed function They work on a 400V three phase power supply and or 230V three phase for the DV models ELECTRICITY SUPPLY absorbed current Ileff is indicated on the device for use at maximum settings Check that the power supply and its protection fuse and or circuit breaker are compatible with the current needed during use The device must be placed in such way that the power socket is always accessible Do not use an extension cable which has a wire section smaller than 4 mm These products are supplied with a
11. YS certifica que estos aparatos de soldadura son fabricados en conformidad con las directivas baja tension 2006 95 CE del 12 12 2006 y las directivas compatibilidad electromec nica 2004 108 CE del 15 12 2004 Esta conformidad esta establecida por el respeto a las normas 60974 1 de 2005 50445 de 2008 EN 60974 10 de 2007 El mar cado CE fue fijado en 2013 GYS 2006 95 12 12 2006 2004 108 15 12 2004 EN60974 1 2005 EN 50445 2008 EN 60974 10 2007 2013 01 02 2013 Societe GYS 134 BD des Loges Nicolas BOUYGUES President Directeur General 53941 Saint Berthevin Nuss France 41 TRIMIG ICONES SYMBOLS ZEICHENERKL RUNG Amperes Amps Ampere Amperios Volt Volt Volt Voltios Hertz Hertz Hertz Hertz Tepu Soudage MIG MAG MIG Metal Inert Gas MAG Metal Active Gas MIG MAG Welding MIG Metal Inert Gas MAG Metal Active Gas MIG MAG Schwei en MIG Metal In
12. aced by the manufacturer its after sales service or a qualified person e Ensure the ventilation holes of the device are not blocked to allow adequate air circulation e Before each use check the state of welding cables of the torch and earth clamp The conductive metal should not be exposed SAFETY Arc welding can be dangerous and can cause serious and even fatal injuries Protect yourself and others Ensure the following safety precautions are taken Arc radiation Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379 Rain steam damp Use your welding unit in a clean dry environment pollution factor lt 3 on a flat surface and more than one meter from the welding work piece Do not use in rain or snow Electric choc This device must only be used with an earthed power supply Do not touch the parts under high voltage Check that the power supply is suitable for this unit Falls Do not place carry the unit over people or objects Burns Wear protective fire proof clothing cotton overalls or Jeans Wear protective gloves and a fire proof apron Ensure other people keep a safe distance from the work area and do not look directly at the welding arc Protect others by installing fire proof protection walls Fire risks Remove all flammable products from the work area Do not work in presence of flammable gases Fumes Do not inhale welding gases and fumes Use the device in a well ventil
13. ated environment with artificial extraction if welding indoors Additional Precautions Any welding operation undertaken in rooms where there is an increased risk of electric shocks Poorly ventilated rooms In the presence of flammable or explosive material Use should always be approved by a responsible expert and made in presence of people trained to intervene in case of emergency Technical protection as described in the Technical Specification CEI IEC 62081 must be implemented Welding in raised positions should not be undertaken except in case of safety platforms use People wearing Pacemakers are advised to see their doctor before using this device Do not use the welding unit to unfreeze pipes Handle gas bottles with care there is increased danger if the bottle or its valve are damaged 12 TRIMIG TROUBLESHOOTING Symptoms Reasons Solutions Clean out the contact batch or change Cracklings block up the opening it and replace the anti adherence product Ref 041806 The welding wire speed is not Control the roller pressure or replace constant di t with The wire skids in the rollers roller Covering Wire guide in the torch non consonant Reel or roller brake too tight Release the brake and rollers The unwinding motor doesn t operate Check that the running button is on Electrical supply problem the position Badwi Covering wire guide dirty or damaged
14. d aluminium neutral gas pure Argon AR is required For specific gas requirements seek advice from your gas distributor The gas flow in aluminium should be between 15 and 25 L min depending on the environment and experience of the welder Things to note when welding with Aluminium Set the pressure of the rollers to a minimum so as not to crush the wire Remove the capillary tube before connecting the aluminium torch When welding aluminium use a special aluminium torch with Teflon sheath to reduce friction TRIMIG Do not cut the sheath near the connector It is used to guide the wire from the rollers fig III B Contact Tip Use the specific Aluminium contact tip corresponding to the diameter of the wire SEMI AUTOMATIC BRAZING FOR HIGH TENSILE STRENGTH STEELS Trimig 200 45 can braze weld high tensile strength plates with Cuprosilictum CusI3 wire or Cuproaluminium CuAl8 wire 2 0 8 mm and 1 mm welder must use a neutral gas pure argon Ar For specific gas requirements seek advice from your gas distributor The required gas flow is between 15 25L min REEL AND TORCH ASSEMBLY FIG IV Open the door of the machine e Position the reel on to the support 3 To place a 200mm wire reel first install the adapter ref 042889 on the support e Adjust the reel brake 4 to avoid the reel movement tangling the wire when welding stops Be careful not to tighten too much Then tighten the plastic scre
15. dado leer las instrucciones de utilizaci n MO Produit faisant l objet d une collecte selective Ne pas jeter dans une poubelle domestique Separate collection required Do not throw in a domestic dustbin F r die Entsorgung Ihres Ger tes gelten besondere Bestimmungen Sonderm ll Es darf nicht mit dem Hausm ll entsorgt werden Este aparato es objeto de una recolecci n selectiva No debe ser tirado en un cubo dom stico He 43 TRIMIG x1 x 10 x3 DD SE 086111 00 6 086166 00 6 Acier Steel Stahl 086126 20 8 086227 20 8 086135 81 0 086234 01 0 041837 041905 20 6 Inox Stainless 042353 00 6 0 8 00 6 0 8 4m am 041950 004 20L min Edelstahl 042360 20 8 1 0 041844 041967 21 0 041998 21 0 043787 041622 FR 25 mm Cuaig 086661008 2 044050 041219 DE 20 8 040939 041059 00 8 Alu 086565 00 8 086524 81 0 042377 80 8 1 0 044067 250A 4m 041066 01 0 21 0 Am Trimig 250 45 DV 230 400V 086227 00 8 x 22 086234 21 0 ee 040922 041950 20 3 0 086241 21 2 042360 08110 08 4m osoa am 041967 210 042384 81 2 1 6 041844 Inox Stainless 01 12 4m 041974 012 Edelstah
16. e work piece please refer to the synergic mode table on the previous page From the settings chosen the Trimig determines the optimum wire speed and the device is ready to weld It is also possible to adjust the wire speed if necessary by adjusting potentiometer or manually 4 The last welding configuration is saved in the memory automatically wire diameter wire type mode ADVICE AND THERMAL PROTECTION e Trimig should not be lifted by its handles torch support or the top of the machine When lifting the Trimig ensure the weight is fully supported at the bottom of the machine There must be no gas bottle connected during this operation e Always respect the basic rules of welding e Do not block cover the ventilation holes of the machine e Leave the device plugged in after welding to allow proper cooling down e Thermal protection If the machine becomes too hot the warning light will illuminate and the machine will stop Cooling will take a few minutes the length of time will also depend on the external temperature DUTY CYCLE AND WELDING ENVIRONMENT IN USE e The welding unit describes an output characteristic of constant current type The duty cycles following the standard EN60974 1 at 40 C 10 cycle are indicated in the table below 60974 1 40 C x max x x 100 Trimig 200 4S 200A 30 140A 120A Trimig 250 4S 250A 30 180A 140A Trimig 300 4S et G 300A 35 240A 180A Trimig 350 4S DUO
17. ert Gas MAG Metal Active Gas Soldadura MIG MAG MIG Metal Inert Gas MAG Metal Active Gas cBapka MIG MAG MIG Metal Inert Gas MAG Metal Active Gas Convient au soudage dans un environnement avec risque accru de choc lectrique La source de courant elle m me ne doit toutefois pas tre plac e dans de tels locaux Adapted for welding in environment with increased risks of electrical shock However the welding source must not be placed in such places S Zeichen Das Schwei en unter beengten Verh ltnissen ist mit diesen Schwei ger ten zugelassen Adaptado a la soldadura en un entorno que comprende riesgos de choque el ctrico La fuente de corriente ella misma no debe estar situada dentro de tal locales Prot g contre l acc s aux parties dangereuses avec un doigt et contre les chutes verticales de gouttes d eau Protected against rain and against fingers access to dangerous parts Schutz gegen Beruhrung mit den Fingern und mittelgroBe Fremdkorper Schutz gegen Tropfwasser Protegido contra el acceso a las partes peligrosas con los dedos y contra las caidas verticales de gotas de agua OT
18. et G DV 350A 35 270 220 Note The machines duty cycle has been tested at room temperature 40 C has been determined by simulation e These are Class A devices They are designed to be used in an industrial or professional environment In a different environment it can be difficult to ensure electromagnetic compatibility due to conducted disturbances as well as radiation e These devices comply with IEC 61000 3 12 provided that the power of the short circuit Ssc is equal to or greater than 3 9MVA 2 8MVA for the Trimig 200 45 at the interface between the machine and the mains power network It is the responsibility of the installer or user of the equipment to ensure if necessary by consulting the operator of the mains electricity that the equipment is only connected to a power supply where the power of short circuit ssc is equal to or greater than 3 9MVA 2 8MVA for the Trimig 200 45 11 TRIMIG MAINTENANCE e Maintenance should only be carried out by a qualified person e Ensure the machine is unplugged and that the ventilator inside has stopped before carrying out maintenance work DANGER High Voltage and Currents GYS recommends removing the steel cover 2 or 3 times a year to remove excess dust Take this opportunity to have the electrical connections checked by a qualified person with an insulated tool e Regularly check the condition of the power supply cord If damaged it will need to be repl
19. l 086326 20 8 30L min 043787 041622 FR 044050 041882 UK 22 20 8 Am 041219 DE Alu 086524 01 0 042377 80 8 1 0 044067 040939 041066 01 0 086531 81 2 042391 81 2 1 6 21 0 Am 250A Am 041073 81 2 044074 21 2 Am Trimig 300 45 300 G 350 45 DUO DV 350 DV Acier Steel Stahl 086227 20 8 2 GE 086234 21 0 251927 040946 041790 20 8 0 086241 012 042360 008 10 0 8 4m osoa Am 419803 910 042384 81 2 1 6 041844 Inox Stainless 086326 20 8 21 12 4m 419810 81 2 Edelstahl 043817 044050 041785 ug 4 20 8 Am 041219 DE Alu 086524 81 0 042377 80 8 1 0 044067 040953 419766 81 0 043824 086531 81 2 042391 81 2 1 6 21 0 Am 350A Am 419773 81 2 500A 4m 044074 Eege 21 2 Am 043800 300A Am 25 mm Acier Steel Stahl 30L min 041622 FR 44
20. l usure normale des pi ces Ex c bles pinces etc En cas de panne retournez l appareil la soci t GYS port refus en y joignant Le pr sent certificat de garantie valid par le vendeur Une note explicative de la panne Apr s la garantie notre SAV assure les r parations apr s acceptation d un devis Contact SAV Soci t GYS 134 Bd des Loges BP 4159 53941 Saint Berthevin Cedex Fax 33 0 2 43 01 23 75 Tel 33 0 2 43 01 23 68 HERSTELLERGARANTIE Die Garantieleistung des Herstellers erfolgt ausschlie lich bei Fabrikations oder Materialfehlern die binnen 12 Monate nach Kauf angezeigt werden Nachweis Kaufbeleg Nach Anerkenntnis des Garantieanspruchs durch den Hersteller bzw seines Beauftragten erfolgen eine f r den K ufer kostenlose Reparatur und ein kostenloser Ersatz von Ersatzteilen Der Garantiezeitraum bleibt aufgrund erfolgter Garantieleistungen unver ndert Ausschluss Die Garantieleistung erfolgt nicht bei Defekten die durch unsachgem en Gebrauch Sturz oder harte St e sowie durch nicht autorisierte Reparaturen oder durch Transportsch den die infolge des Einsendens zur Reparatur hervorgerufen worden sind Keine Garantie wird f r Verschlei teile z B Kabel Klemmen Vorsatzscheiben etc sowie bei Gebrauchsspuren bernommen Das betreffende Ger t bitte immer mit Kaufbeleg und kurzer Fehlerbeschreibung ausschlie lich ber den Fachhandel einschicken Die Reparatur erfolgt e
21. lding units Das Ger t entspricht der Norm EN60974 1 f r Schwei ger te El aparato esta conforme a la norma EN60974 1 referente a los aparatos de soldadura EN60974 1 Transformateur redresseur triphasee Three phase converter rectifier Dreiphasiger Trafo Frequen zumwandler Transformador rectificador trifasico 409 Facteur de marche selon la norme 60974 1 10 minutes 40 C Duty cycle according to the standar EN 60974 1 10 minutes 40 C Einschaltdauer gem EN 60974 1 10 Minuten 40 C Factor de marcha seg n la norma EN 60974 1 10 minutos 40 C EN 60974 1 10 40 C 2 12 courant de soudage conventionnnel correspondant 12 corresponding conventional wel ding current 12 entsprechender Schwei strom I2 Corrientes correspondientes 12 X U2 Tensions conventionnelles en charges correspondantes U2 conventional voltages in corres ponding load U2 entsprechende Arbeitsspannung U2 Tensiones convencionales en carga U2 42 TRIMIG Appareil conforme aux directives europeennes The device complies with European Directive Ger t
22. on reglaje de velocidad de hilo Bouton SPOT DELAY SPOT DELAY button SPOT DELAY Poti boton SPOT DELAY SPOT DELAY Clavier de commande Control Keyboard Bedienfeld Teclado de mando Interrupteur I O I O Switch Netzschalter AN AUS Conmutador ON OFF Commutateur Switch Spannungsschalter Conmutador Motodevidoire sans galet Wire feeder without roller Drahtvorschub ohne Drahtf rderrollen Devanadera sin rodillos sin rodillo Cable d alimentation Supply cable Netzstromkabel Cable de alimentacion Support bobine 15Kg Reel support 15 Kg Drahtforderrollen 15Kg Soporte de bobina 15kg 15 Kr Roue avant Front wheels Vorderrad Rueda de atras Pont de diodes Diode bridge Gleichrichter Puente de LED Self Induction oil Self Drossel Thermostat Thermostat Thermostat termostato Transformateur Transformer Trafo Transformador Ventilateur Fan Ventilator ventilador Roue diametre 200mm 200mm diameter wheels
23. rst nach Erhalt einer schriftlichen Akzeptanz Unterschrift des zuvor vorgelegten Kostenvoranschlags durch den Besteller Im Fall einer Garantieleistung tr gt GYS ausschlie lich die Kosten f r den R ckversand an den Fachh ndler 40 TRIMIG DECLARATION DE CONFORMITE GYS atteste que ces postes de soudure sont fabriques conformement aux exigences des directives Basse tension 2006 95 CE du 12 12 2006 et aux directives 2004 108 CE du 15 12 2004 Cette conformite est tablie par le respect des normes harmonisees EN60974 1 de 2005 EN 50445 de 2008 EN 60974 10 de 2007 Le marquage CE a ete appose en 2013 DECLARATION OF CONFORMITY The equipment described on this manual is conform to the instructions of low voltage 2006 95 CE of 12 12 2006 the instructions of CEM 2004 108 CE of the 15 12 2004 This conformity respects the standards EN60974 1 of 2005 EN 50445 de 2008 EN60974 10 of 2007 CE marking was added in 2013 KONFORMIT TSERKL RUNG GYS erkl rt dass die synergisch geregelten Schwei anlagen TRIMIG 200 45 250 45 DV 300 4S 300 G 350 45 DUO DV 350 G DV richtlinienkonform mit Niederspannungsrichtlinie 2006 95 CE 12 12 2006 und EMV Richtlinien 2004 108 CE 15 12 2004 elektromagnetische Vertr glichkeit hergestellt wurden Diese Ger te stimmen mit den harmonisierten Normen EN60974 1 von 2005 EN 50445 von 2008 EN60974 10 von 2007 berein CE Kennzeich nung 2013 DECLARACION DE CONFORMIDAD G
24. s separates Drahtvorschubger t connector cable de tierra 51469 51461 1 4 S lecteur 230 400V Voltage selection switch 230 400V Umschalter 230 400V Selector de tensi n 230 400V 75012 75012 230 400B Pour les postes avec d vidoir For machines with wire feeder Ger te mit separatem Drahtvorschubger t Para equipos con devanadera Passe cloison de Gaz Gas connector Schutzgasanschluss 2 Ausgang f r separates Drahtvorschubgerat Conector de gas B Connecteur de commande Wire feeder control connector Steueranschluss separates Drahtvorschubger t Conector de mando Interrupteur de selection du potentiometre Potentiometer selection switch Potentiometer Auswahlschalter Interruptor de selecci n del potenci metro Ha 39 TRIMIG CONDITIONS DE GARANTIE FRANCE La garantie n est valable que si le bon correctement rempli par le vendeur La garantie couvre tout defaut ou vice de fabrication pendant 1 an a compter de la date d achat pieces et main d uvre La garantie ne couvre pas les erreurs de tension incidents dus un mauvais usage chute d montage ou toute autre avarie due au transport La garantie ne couvre pas
25. w 2 firmly e The wire feeder uses double groove rollers 8 0 8 1 1 0 1 2 The visible diameter on the roller when fitted is the one currently in use For 1 mm wire use the 1 groove For first use Release the fixing screw of the wire guide 5 Place the rollers and tighten the screws 9 Place the wire guide 7 as close as possible to the roller but without touching it then tighten the fixing screw To select the adjustment of the drive rollers 6 loosen the knob fully Start the motor by pressing the trigger of the torch tighten the knob whilst pressing the trigger until the wire starts to move Bend the wire where it comes out of the nozzle and hold it in place to stop its progress The setting is correct when the guide roller slides over the wire even when it is blocked at the end of the torch e Common adjustment of knob 6 scale 3 4 for steel and scale 2 3 for aluminium CHOICE OF REELS Possible settings Wire type Se 2 200 Consider Teflon sheath and special aluminium contact tip GAS COUPLING Fit the regulator flowmeter to the gas bottle and then fit the gas pipe to the connector To avoid gas leaks use the collars provided in the accessories box Ensure proper maintenance of the gas cylinder in accordance with the attachment of the chain cf 1 CONTROL PANEL FIG V Welding mode selection 2 2T two stage welding Synergic Mode 3 4T 4 stage welding