1. Uninstalls the driver for the selected device Illustration 2 24 Uninstall USB drivers on Windows Vista Step 1 Windows Vista provides an automatic method to delete driver files via check box Delete the driver software for this device on the uninstall dialog box Just mark the check box and click OK to remove the installed USB drivers of your device Confirm Device Uninstall OKM Quick Link Waming You are about to uninstall this device from your system Delete the driver software for this device Illustration 2 25 Uninstall USB drivers on Windows Vista Step 2 OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 27 2 3 Windows 7 The instructions in this section are only valid for the Windows 7 operating system 2 3 1 Install USB drivers on Windows 7 The installation of the USB drivers on Windows 7 is a little bit different as known from previous Windows versions Connect the device to a spare USB port on your PC and make sure everything is switched on Windows 7 is now trying to install the latest USB drivers and displays the message from figure 2 19 Installing device driver software gt Click here for status 12 49PM 12 7 2009 Paz m I Illustration 2 26 Install USB drivers on Windows 7 Step 1 Shortly after this Windows 7 will bring up a new message as shown in figure 2 20 to inform you about the fact that it
2. OKM Ortungstechnik GmbH www okmmetaldetectors com Technical Specifications 34 Technical Specifications The following technical indications are medial values During operation small variations are quite possible 3 1 Control Unit Dimensions LSV X DV ee oe eve din ce sc ie ee ea 430 x 150 x 260 mm NY SG ne ee ee about 3kg MOV AG eE T E EEE ERA EA AE E AE AAE 9 6 14 4 VDC 22 W maximal E Oli ee oan A ee IP40 Operating Time full charged Power Pack 25 C zesesesesssssssnenenessenenennenensnnsenennsneneneesn nenn about 3 hours Operanng 10m pPE raure eee eer erent EE NET 0 C 40 C DI DV ea E EE 300 mcd Background lighting 6 4 Diagonale 640 x 480 Pixel TFT Color COMPULET anreisen 800 MHz Processor INTEL i586 compatible Working Memory RANE een ares semnouneats 256 MB Da COLE Genese Re Eine 256 MB FC CG en aaa ee ee ern slhe accustic visual Storage TEIIPETIEULG ee ee ee EEE TE 20 C 60 C DS STU CLAY a ee ee ee 5 75 VV OTTO OO ee A E E OE E nee No Sensor technology air en Tee TCFX 01 A 3 2 Data Transmission TECHNO 00U re EEE TEEN OEA E EAEAN USB Maximal Data Transmission Rabe ia aaa sata een TORETE E Ur EEE Gada ceeds 19200 Baud 3 3 Computer Minimum Requirements The computer is not part of the scope of delivery The indicated values should help you for a correct selection of a suitable computer for analysis of your measured results POC OT e
3. Go to your start position and adjust all necessary parameters to your needs Then you have to select option Start Scanning to start the measurement The message from figure 7 6 will appear and ask you if you are ready to start your first scan line now f Do you want to scan f the first line now Po x 7 Illustration 7 6 Start first scan line While using the keys W and M select option Yes if you want to start the measurement Confirm your selection by pressing the OK key As soon as you press the OK button begin walking immediately for the eXp 4000 is now recording data As soon as your first scan line is finished a new message will appear where you have to select Yes if you want to scan another measured line OKM Ortungstechnik GmbH www okmmetaldetectors com Operating Modes 51 Repeat this procedure until your complete area is scanned Step by step a graphical representation similiar to figure 7 7 will appear Illustration 7 7 Graphical Representation ofa Measurement in Operating Mode Ground Scan The graphic where a target is present should primarily be a green color for the background which represents normal ground In this green area red and blue objects can be placed Metallic objects are normally represented in red and cavities water reserves and earth interferences in blue colors Areas where ground mineralization is present is often shown in red also 7 2 2 Browse Scans After selecting th
4. Illustration 2 1 Install USB drivers Windows XP Step 1 If your Windows XP has Service Pack 2 installed you will see the dialog from figure 2 2 if Windows Update has to search for drivers up to date Mark entry No not this time and click on Next Assistent fir das Suchen never Hardware Willkommen Es wird nach aktueller und aktualisierter Software auf dem Computer auf der Hardiwareinstallations CD oder auf der Windows Update website mit Ihrer Erlaubnis gesucht Datenschutznchtlinie anzeigen Soll eine Yerbindung mit Windows Update hergestellt werden um nach Software zu suchen Ja nur diese eine Mal Ja und jedes Mal wenn ein Ger t angeschlossen wird Klicken Sie auf Weiter um den Yorgang fortzusetzen 4 Zuruck Abbrechen Illustration 2 2 Install USB drivers Windows XP Step 2 In other versions of Windows this window should not appear In the following dialog window like figure 2 3 select the entry Install software from a list and click Next OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 15 Assistent f r das Suchen neuer Hardware Mit diesem Assistenten konnen Sie Software f r die folgende Hardwarekomponente installieren OKM Quick Link C Falls die Hardwarekomponente mit einer CD y oder Diskette geliefert wurde legen Sie diese gt jetzt ein Wie mochten Sie vorgehen Software automatisch inst
5. The device stops at the end of each finished scan line so that the user can find the starting position of the next line In this way all paths will be recorded and the area will be measured Figure 8 1 shows all 4 possible starting positions and the corresponding first scanning path Depending on the composition of your terrain you can determine the optimal starting point for your measurement by yourself Start of 1 scanning path End of 1 scanning path Figure 8 1 Starting position of a scan area The scanning paths may be referred as Zig Zag or Parallel traverses Also the number of impulses measure points which are recorded during one scanning path can be adjusted individually depending on the size of your scan area length of scanning path 8 1 1 Scan Mode There are two general techniques to surveying an area with the eXp 4000 e Zig Zag The starting position of two scanning paths next to each other is on the opposite side of the measured area You will record data on your scanning path and on the return path as well e Parallel The starting position of two scanning paths is always on the same side of the measured area You will only record data in one way and in one direction while you should return and walk back to the starting position of the next scanning path without recording data Figure 8 2 represents both techniques schematically OKM Ortungstechnik GmbH www okmmetaldetectors com F
6. SNAMETE EE E ne re ia ele tnedy se E EEE A A oe E E E EE 1 2 20 A S E essen SPS A rA Daa E EEEE EEEN Da E ee ee ee ee SE ie tote le ee elo ee ee FeBEBEREBE BESRBEREBEEBER EER OKM Ortungstechnik GmbH www okmmetaldetectors com Illustration Index Illustration 2 1 Illustration 2 2 Illustration 2 3 Illustration 2 4 Illustration 2 5 Illustration 2 6 Illustration 2 7 Illustration 2 8 Illustration 2 9 Illustration 2 10 Illustration 2 11 Illustration 2 12 Illustration 2 13 Illustration 2 14 Illustration 2 15 Illustration 2 16 Illustration 2 17 Illustration 2 18 Illustration 2 19 Illustration 2 20 Illustration 2 21 Illustration 2 22 Illustration 2 23 Illustration 2 24 Illustration 2 25 Illustration 2 26 Illustration 2 27 Illustration 2 28 Illustration 2 29 Illustration 2 30 Illustration 2 31 Illustration 2 32 Illustration 2 33 Illustration 2 34 Illustration 2 35 Illustration 2 36 Illustration 2 37 Illustration 5 1 Illustration 5 2 Illustration 5 3 Illustration 5 4 Illustration 6 1 Illustration 6 2 Illustration 6 3 Illustration 7 1 Illustration 7 2 Install USB drivers Windows XP Step 1 ou cece cc ec ececencecesenceceneececenseeeeeeesensenseenes 14 Install USB drivers Windows XP Step 2 cece cece cc ecececencececenseceneecesensenseessesensenseenes 14 Install USB drivers Windows XP Step 3 ce 15 Install USB drivers Windows XP Step 4 ccc
7. Further information about the correct usage of the detector and the principle of discrimination you can find in section Optional Equipment DDV system of this users manual OKM Ortungstechnik GmbH www okmmetaldetectors com 54 Operating Modes 7 4 Discrimination This operating mode is used to identify metals and cavities Therefore it is necessary to connect the optional available Supersensor If you don t have the optional Super Sensor contemplate very seriously on acquiring one This is an extremely powerful function and can assist you in verifying real targets There are three basic modes in which you will use this function Discrimination of course tunnel recognition and then also when on the water from a boat For water operations please contact one of our trainers at the factory to receive a more detailed operation In this section we will only cover Discrimination and Tunnel Recognition In this mode there is no given manner fixed or a scan direction You can walk as you want to determine the soil This operating mode is most effective if you have already detected possible objects and now want to know more details about them Ground Scan Metal Detector Exit Beeorw 2 18 v1 8 666 Th 3 A Ba L Illustration 7 11 Discrimination The Supersensor should point vertical towards the ground It should not be turned or pivoted Now you can slowly move the Supersensor from one side to another above the possible o
8. OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 29 In the Device Manager see figure 2 27 there will be a device under Other devices with a yellow warning symbol to indicate a problem i e no driver installed The text next to this device will depend on the device attached In this example the device was an eXp 4000 device Right click on the other device eXp 4000 in this example to bring up a menu as shown below gt Device Manager File Action View Help eB aAlE BA e Fee a g user PC gt gil Computer aca Disk drives MS Display adapters DVD CD ROM drives 4g IDE ATA ATAPI controllers 5 Keyboards JA Mice and other pointing devices ME Monitors EF Network adapters l Other devices lp xp anna gt e Ports Ci Update Driver Software b Frocessd Disable bm Sound Uninstall gt lt gt Storage b ii System q Scan for hardware PET io Stang Properties Launches the Update Driver Software Wizard for the selected device Illustration 2 31 Install USB drivers on Windows 7 Step 6 From the displayed menu select Update Driver Software which then displays the option for an automatic or manual search Select the second option to browse manually Update Driver Software eXp 4000 How do you want to search for driver software gt Search automatically for updated driver software Windows will search your co
9. some functions which have to be used for an initial first measurement in an unknown area to get a general overview whereas others are more suitable for a more detailed search and analysis with a special processing software program The eXp 4000 has the following operating modes e Magnetometer Search an area with the integrated magnetometer e Ground Scan Measurement with graphical evaluation whereby measured data can be stored in the internal memory of the device for later review Metal Detector Activate optional DDV system to discriminate between metals Discrimination Examination of detected objects regarding their characteristics on iron contents e Empty Memory Delete all data stored in the internal memory e Exit Power off the device and shut down the integrated PC module If you are connecting the optional FS Thermoscan to the eXp 4000 there will be two more operating modes available Without FS Thermoscan those functions are inactive and not visible e Thermograph This operating mode is used to view and analyze differences in temperature measured with FS Thermoscan e Thermo Scan In Thermo Scan you can create graphical infra red images to visualize the distribution of temperatures of a field Both operating modes will be visible in the main menu as soon as the optional device FS Thermoscan is connected to the eXp 4000 These options are useful for seeking cavities Via the touchpad on t
10. N N Sensitivity Discriminator regulator LED Connector plug Illustration 9 2 Control Elements of the Detector To use the DDV system just plug in the connector plug into the control unit of your eXp 4000 Then select the operating mode Metal Detector in the main menu Attention As soon as you confirm this option the ground balance will start Detailed information you can find in section 9 2 3 on page 70 Now you have to pivot the detector coil continiously right above the ground trying to keep the same distance to the soil Adopt the rhythm of the graphical representation on the screen As soon as you pass above a metallic object a yellow colored trace will appear in your graphic and you can hear an acoustical sound through the headphones 9 2 1 Calibration The manual calibration is only possible for product version V1 1 and following In case of need all former product versions have to be calibrated from the manufacturer The version of your device you can read inside the main menu Before using the metal detector for the first time the DDV system has to be adjusted on the eXp 4000 If you purchased the DDV system together with the main unit the metal detector has already been OKM Ortungstechnik GmbH www okmmetaldetectors com 9Optional Equipment 68 calibrated in the optimal way Anyway you have the possibility at any time to recalibrate the DDV system Therefore
11. Start button but is more comfortable and can facilitate the measurement procedure OKM Ortungstechnik GmbH www okmmetaldetectors com 44 Control Elements With the keys W and you can select the operating mode To confirm your selection you have to press the OK button 6 1 2 Rear View Figure 6 3 shows the rear view of the control unit and its connections Display A Connector for Headphones IES a USB cable CE Connector for Connector for Connector for probe power supply headphones Illustration 6 3 Control unit rear view The connector for the power supply is used to connect the battery There the external power supply has to be plugged in On the probe connector the different probes as well as the DDV system can be connected The connector for the headphones is used to plug in the delivered headphones enabling the user to hear an audio output Via the connector for the USB cable the device can be connected to a computer via the USB cable This is necessary to transfer data from the device to a computer OKM Ortungstechnik GmbH www okmmetaldetectors com HAP TE Operating Modes In this section you will learn more about the different operating modes of the eXp 4000 Every function is explained in its proper subsection 46 Operating Modes Selecting the correct operating mode depends primarily on the desired output So for example there are
12. are limited In this case repeat the scan and change the position of your scan area to receive an optimal position of the anomaly inside of the graphic e There should not be more than one object in a scan This will influence the depth measurement It is useful to scan partial areas over such targets e You should do at least two controlled scans to be more sure about your results This is also important to recognize areas of mineralization e Most important rule when dealing with mineralization REAL TARGETS DON T MOVE If your target moves then it is most likely mineralization 8 2 1 Orientation of probe During one measurement the probe should have always the same distance to the ground Generally we recommend a height of about 5 15 cm from the surface of the ground if possible In the event that you are going to go over stones wood or high grass that is higher start your scan with the sensor higher right from the beginning In circumstances like these then perhaps you will need to start the scan with the probe at a height of 2 feet 50 cm and keep it at that level for the entire scan It is important to maintain the height this will eradicate many errors As a rule do not change the height during a scan for it may create unnecessary errors Another important aspect is the physical orientation of the probe During the Parallel scan mode the orientation of the probe does not change because you are always measuring in
13. cc sisc cies ocean tewase ea 15 Install USB drivers Windows XP Step ou cece cece cence ceetececeeseceneesecenseeseesetensenseeges 16 Install USB drivers Windows XP Step 6 u ann 16 Uninstall USB drivers Windows XP Step 1 2 0 cece ccc ccecececeeceeeneneeceenseceneeseeseeseenes 17 Uninstall USB drivers Windows XP Step 2 2 0 cece cece ec ececcncececeneecesencecenenseceneneeeseeseenes 17 Uninstall USB drivers Windows XP Step 3 2 0 ccc cece ec ececeecececeneeceeneecesenseceneeseeseeseenes 18 Uninstall USB drivers Windows XP Step 4 ccc cece ec eceeenceceneececeneeeeeneesessenseeseens 18 Uninstall USB drivers Windows XP Step 5 au uuu uu uuu a an 19 Install USB drivers Windows Vista Step 1 uu cece cece ececcecececeececeeececensensenseeeeeseenes 20 Install USB drivers Windows Vista Step 2 ccccececcecececencececencecencesecenseseenseesenseenes 20 Install USB drivers Windows Vista Step 3 sssessessseesensnnensnnnnensnnnnennnnnsnesnnseesnessnenen 21 Install USB drivers Windows Vista Step 4 essesessssesesssnssnsssnnnnsnnnnnsennennsnennnsensnesnnenen 21 Install USB drivers Windows Vista Step 3 essssesessesesssnnnnsssnnenssnnnesennnnesnesnnsnnsnesnnenen 21 Update USB drivers on Windows Vista Step 1 sssesesessessssssesssnnesennnnenennnnesennen nenn 22 Update USB drivers on Windows Vista Step 2 eeeseseesesesssnesssnnnsessnnenennnnenennnneennen nenn 22 Update USB drivers on
14. example worthless iron and steel objects Or people who are hunting for treasures and gold are able to exclude other materials with the help of this discriminator Illustration 9 5 Adjustment of discrimination In figure 9 5 the regulator to adjust the discrimination is represented This regulator can filter certain materials Table 2 explains the adjustment in the case of normal ground conditions Adjustment Indicated materials 0 All metallic objects 3 Iron gold bronze silver aluminium 5 Gold bronze silver aluminium 7 Silver aluminium 10 Aluminium Table 2 Standard adjustment of the discrimination When you adjust the regulator for discrimination on gold the detector reacts besides gold also on bronze silver and aluminium To find out if there is really gold in the ground you have to follow the following instructions 1 Switch the discriminator on gold and start your soil examinations until you reach a place where the detector reacts positive which means you can hear an accustical sound signal 2 Now switch the discriminator on silver and examine this place again Following there will be two possibilities e The detector reacts positive The material under the ground is not gold but could be silver or aluminium e The detector does not react There is probably golden material in the ground but also bronze is possible Please consider that you always should do the ground balance which is exp
15. natural to the soil Other targets that you can use in your own area are buried utilities Pipes tanks electrical sewers graveyards etc Most of these items can be found in every community town or city This is where you need to begin your training if you are going to self train e Get professional training When you take advantage of receiving the training either from the factory or a qualified dealer you will understand not only the use and operation of the OKM detector but also the software so much easier and be able to identify targets as well as errors e Do not rely on just one scan measurement So many users go out into the field and they make a measurement and see a target Instead of repeating the scan and reproducing it several times they go out and get a shovel and dig On very rare occasion will the first scan be perfect Even the trainers do multiple scans to ensure that they are not looking at areas of mineralization or an error OKM Ortungstechnik GmbH www okmmetaldetectors com Field procedure Soil Mineralization Oh Very frustrating We will all experience it When you are in an area that is known to have pockets of mineralization be prepared to conduct more scans than normal o Clay is probably the number one foe Depending on the iron content of the clay will determine how strong the attenuation will be A quick rule of iron content is how dark it is it can vary from a light gray up to a dark ora
16. of the DDV system step 2 ssssssssesssessesssessesseessessoesoesseesoeeseesoeeseeseeessseeeeesso 68 Illustration 9 5 Adjustment of discrimination sssesssessessresessessesersseserseesessessessessesoesseseesocseesoesesseesesese 69 Illustration 10 1 Only a small amount of memory available ussssssssssssssssssnsnensnenenennnnnnnnnnen nenn 72 Illustration 10 2 No free memory available cece cece eee eee ee ee eeeeen ee eneeeeseseseneaeaseseseaeaeneaeeegs 72 Illustration 10 3 Internal Hardware Error cccccccseecscscececececenenescecececeaeenessesesececeaeeseeceesessessessessess 12 Illustration 10 4 The external power supply has to be charged uz2ssssssssensnesennsennnsnesnennenenn nenn 73 INhustration 70 5 Shutting down the syster session 73 Illustration 10 6 Shutting down the system is not possible sessseseesseseesnnennnnnnnnnnnnnnnnnnnnnnenenn nen 73 OKM Ortungstechnik GmbH www okmmetaldetectors com CHAPTER 1 Introduction 8 Introduction 1 1 Preface Dear customer all of the engineers sales training and support staff at OKM Ortungstechnik GmbH would like to thank you for your purchase of the eXp 4000 The eXp 4000 detector works on the principle of Electro Magnetic Signature Reading EMSR Besides the detection of metallic objects this device is also capable of detecting natural features of the earth like formations of strata cavities voids
17. to the main amplitude there is another small peak which is typically for precious metals Also here the order of amplitude and the small peak is not important and depends on the scan direction Non metallic targets All non metallic items have a pure negative signature Illustration 7 14 Signature of a non metallic target The last of the typical signatures is represented in figure 7 14 It is the signature of all non metallic targets and structures These can be voids tunnels or buried plastic pipes or boxes You can recognize that there is only a negative amplitude blue 7 5 Empty Memory The Empty Memory mode is used to delete all data which is stored in the internal memory of the device If you confirm this option you will be asked again if you really want to delete all data If you confirm now by pressing Yes all data will be deleted and cannot be rebuilt or transferred to a computer OKM Ortungstechnik GmbH www okmmetaldetectors com 56 Operating Modes Yiew Gran Imasa w Do you really want to Magnetometer Ground Scan Discrimination gne delete this scan image 4 ER 7 8 Metal Detector Exit Beeorw 2 18 Illustration 7 15 Empty Memory 7 6 Exit You have to select the Exit mode to finish the operation with this unit and to power it off As soon as you confirmed this selection the integrated pc module will shut down and the device will power off itself Magnetometer Ground Scan Discrimi
18. visit our web site Our equipment is constantly being tested and when improvements or upgrades are available we will list them also on our web site It is necessary for our company to protect our developments and all of the information learned during the Research and Development phases in creating our technology We strive to stay within the given framework of legislation patents and trademark registration Please take your time to read this User Manual and familiarize yourself with the operation functionality and how to utilize the eXp 4000 We also offer training for your equipment in our factory and on site We strive to maintain worldwide dealer network for assistance and support Please visit our web site for more information OKM Ortungstechnik GmbH www okmmetaldetectors com Introduction 9 1 2 Important Notes Prior to using the eXp 4000 and its accessories please read these operating instructions carefully These instructions give information on how to use the detector and potential sources where precautions should be taken The eXp 4000 and its accessories serve for the analysis documentation and detection of sub surface anomalies and ground disturbances The recorded data of the ground structure will be transmitted to a PC to give a visual representation using our proprietary software program Any additional notes to the software should be observed Please read the user manual of the software 1 2 1 Genera
19. you have to activate at first the operating mode Metal Detector Place the DDV system on the ground like shown in figure 9 3 Take care that no metal is situated near to the coil Press the key OK to start the calibration Illustration 9 3 Calibration of the DDV system step 1 In the first step of calibration you have to turn the sensitivity regulator completely to the right side and so adjust it on full power The discriminator has to be adjusted on the value 0 Take care that no metal is located near to the coil Now press the key OK to start the calibration Wait until this process is finished Illustration 9 4 Calibration of the DDV system step 2 In the second step of calibration you have to leave the sensitivity regulator in the same position and place a piece of iron e g screw or nail under the detectors coil Alternative choice is to place the metal directly on the top of the coil like you can see in figure 9 2 Now press again the key OK and wait until this process is also finished After finishing the calibration a visual signal yellow light should be visible on the screen If the headphones are connected you will also hear an acoustical signal The DDV system is now calibrated to work correctly on site OKM Ortungstechnik GmbH www okmmetaldetectors com 69 Optional Equipment 9 2 2 Adjust the discriminator The discriminator serves to filter certain materials So it is possible to exclude for
20. 2 Update USB drivers on Windows Vista If you need to update the USB drivers on your operating system or the initial installation failed please open up the Device Manager of Windows Vista Therefore press the Windows start button and click on Control Panel Eh E mail A Windows Mail Sg Visualizer 30 ga BlueSoleil Paint Y dhe Backup and Restore Center E ey Calculator Internet FF Internet Explorer Documents Pictures Music Games Recent Items Computer Network Connect To Control Panel Default Programs gt All Programs Help and Support Start Search pa 5 Tr FE zum Illustration 2 17 Update USB drivers on Windows Vista Step 1 At the next screen shown in figure 2 18 select View hardware and devices which can be found on the bottom of the left sidebar OD t Control Panel Control Panel Home Classic View Recent Tasks i Cp View hardware and devices Get started with Windows System and Maintenance Get started with Windows Back up your computer Security Check for updates Check this computer s security status i Allow a program through Windows Firewall Network and Internet Connect to the Internet View network status and tasks Set up file sharing Hardware and Sound Play CDs or other media automatically Printer Mouse ern Ill Programs Uninstall a program Change startup programs User Accounts and Family Safety Fg Set up parental control
21. E A E E ER IE iy lls da Erne NOW sc conccaanaauieadene nan E r EON EEE EETA A REEE E a Be a ee a asin a a A N A E E A A ZINSEN ren iUe NEN errar EN AEAEE PESEE ENN EEren ai EA MagnoloMbLOE erris iit ri eee nt eee OAIE ene ee er rt ee ener RTS Fe ARE OTE EEE A EEE E T N ee VIL EEE A E nn unuunenn inane aceeseoninnsabe Venn eononsaceqacanmunabenne ness EES s CON iol om I een Cen eRe ee ne eee eRe Te ee DEI NIE De ta eae ies Sree cies nern FL DOT ee waco pe ee ee TEED Mea A at eee OIE a EA NEEE OKM Ortungstechnik GmbH www okmmetaldetectors com IN RAMEN ee ee aban neta eens eat 72 DIOR N een ENT EEE PS WN 2 2 10 EEE E EEE O Field GUNG Le 210 1 gt EEE eter ee earn ene IUELERUEREEUUEUEREREEUENCHEONTEURERETEEEEEUEEHENERTERERTENERHETTERERTEURNEREREORIERESEUERLERURGE Gk General SCANMING PVOCCUUNS een ker 520 BG eye AMUN 1015 RENTE BENENNEN REGAL REEENE FEN EN ER NONE EEE PIERRE E RER U VER RE NEL NIE RER ER ORIEINERRNERRNE 8 1 2 Regulation of the number of impulses per Scanning Path esesesssssssssenesensnesnesnesnennenenn DMA opodal advices Tor Tel DIOCOOUIE veria a EEEE EEEE E E BF TONE eine AEE EEEE EEA Oee Pa elor an ee E E EE EA EA EEA 8 2 3 Manu al or automatic impulse TONE Fas irindtenuiiedad og dansaserseauadnbncnd snes da cenvansdaadaadiadhondadaiasdpnoareiaiars 8 2 4 Tips from the trainers themselves cccccccsccscscscecececcacscseececececccseeesesesceacsesseesceesessesses
22. E EIEOIEREEREEUFSURUERENZERRSEREUFGENEURELEEEENERENHEERERTEGR 14A Possible Health Hazards ernennen 12a UI ATEO arer re EEEE EEEE EEEE EEE NN j E E L EE O E E E E nenne EA E a EE EE EE E E To ME Wi iene Waele mU DEN Lei lt gt nen EEA E A EEA 1 4 Danger of Explosion during Excavation eu 2 Install Uninstall USB drivers on Windows esesessesesesesenessenennnnensnnsenennnnensnesesesnenenen ER BB WEN a E A SAW REEL EUER EREREERENEEEEEREFERUUENENFEREELERELERNENEIUERUIEEURERERERRRESEREN 2 1 1 Install USB drivers on Windows XP seinen 2 1 2 Uninstall USB drivers on Windows XP essen ensure PARE I A A EE E E I A E E E ie Fue E E ATAA 2 2 1 Install USB drivers on Windows Vista ecesesessesensnesesensenenenennenennsennnnenenen 2 2 2 Update USB drivers on Windows Vista ccccsccsvscrccsvectecscncssvecnecsveces 2 2 3 Uninstall USB drivers on Windows Vista ess ssseeersseccesseccresescccsseecee ee ge ED ee ee ee ee 2 3 1 Install USB drivers on Windows 7 2 2 cece cece cece cc cncccceccccccecccccceecscceeccaceees 2 3 2 Uninstall USB drivers on Windows 7 xicccccssicvedsevelecacadisvexaeevececeacieiwbesseasndes 3 lechnical OO ee ONS ee erlernen iiai CAEP onea RE i aE E E EET E EAA E A E E TEE EA 3 A Er Ta an ee ee er 3 3 Computer Minimum Requirements sescsrecsssssssssrsssrisererrisescsitnsssssssisssseterasss A opera DOTE ar A RE E E EEEE RE AE E E E MN E men ounsi a EE R Eanna EE iA E A van A E EE T
23. FS Future Series eXp 4000 Version 2 1 User s Manual Any information contained in these operating instructions may be changed without prior notice OKM does not make any warranty for this document This also applies without limitation to implied assurances of merchantability and fitness for a specific purpose OKM does not assume any responsability for errors in this manual or for any incidental or consequential damage or loss associated with the delivery exploitation or usage of this material This documentation is available as presented and without any kind of warranty In no circumstances OKM takes responsibility for lost profits usage or data losts interruption of business activities or all kind of other indirectly damages which developed because of errors in this documentation This instruction manual and all other stored media which are delivered with this package should only be used for this product Program copies are allowed only for security and savety purposes The resale of these programs in original or changed form is absolutely forbitten This manual may not be copied duplicated or translated into another language neither in part nor completely over the copyright matters without the prior written consent of OKM Copyright 2002 2010 OKM Ortungstechnik GmbH All rights reserved Table of Contents aS a e A a a E E T T E aso daa Sentara baa E T E EE TEO r A E E E LA Bapor DIOR een 1 2 1 General Notes EH
24. Set up parental controls for any user Appearance and Personalization Change the theme Change desktop background Adjust screen resolution Clock Language and Region Change keyboards or other input methods Change display language Ease of Access Let Windows suggest settings Optimize visual display Illustration 2 29 Install USB drivers on Windows 7 Step 4 At the next screen shown in figure 2 30 select Device Manager which can be found under Devices and Printers leg Control Panel Hardware and Sound Control Panel Home ai System and Security Cy BEA DENEE Network and Internet Hardware and Sound Programs Sound User Accounts and Family Safety Appearance and Personalization Clock Language and Region Ease of Access Display Make text and other items larger or smaller Adjust system volume 47 Devices and Printers Add a printer RI AutoPlay Change default settings for media or devices Power Options Change power saving settings Require a password when the computer wakes Choose a power plan Connect to an external display Change system sounds 4 Search Control Panel p Mouse W Device Manager Play CDs or other media automatically Manage audio devices Change what the power buttons do Change when the computer sleeps Adjust screen resolution How to correct monitor flicker refresh rate Illustration 2 30 Install USB drivers on Windows 7 Step 5
25. Windows Vista Step 3 sesesessesesssnessssnssensnnnnennnnenennnneennen nenn 23 Update USB drivers on Windows Vista Step 4 sssssssssesssessseesreesseeserreseessseesereeseeessese 23 Update USB drivers on Windows Vista Step sesessssesssssnessssnnsesennenennnneennnneennen nenn 24 Update USB drivers on Windows Vista Step 6 zessssesessssessssnnsessnnnnennnnenennnneennen nenn 24 Update USB drivers on Windows Vista Step 7 eeeceseseesesesssnesssnnnensennenennnnenennnneennen nenn 25 Uninstall USB drivers on Windows Vista Step 1 ezsssesessssessssnsssssnnesennnnnnnnennen nenn 26 Uninstall USB drivers on Windows Vista Step 2 eesesessesesssssnesssnnssensnnenennnnnnnnennennenn 26 Install USB drivers on Windows 7 Step 1 e sesesessesessssesessenenssnnnnnnennennnsnnsnesnnsnnenen 27 Install USB drivers on Windows 7 Step 2 eeseseesesessesenessenensenenensennnnsnennnnnesnnsneseessnenen 27 Install USB drivers on Windows 7 Step 3 eeceseseesessssenessenensesennnnennenenennennennnnnssnesenenen 27 Install USB drivers on Windows 7 Step 4 ssssssssessssessseessesesrcsssreseeesseresseeeeeeesseerereeee 28 Install USB drivers on Windows 7 Step essssesssssssessseessecssecssseeseecesersssereeeesssesreeeeeee 28 Install USB drivers on Windows 7 Step 6 eceseesesessessssesessenennnsennnnnsennennennnsnesnesnnenen 29 Install USB drivers on Windows 7 Step 7 sssssssssssssessseesseesseesssres
26. aces or overgrown areas it is wise to use the manual impulse mode Because each impulse will be released manually you have enough time to position the probe in the correct way and record the measured value In this way you can also measure accurately previously marked dots of a predefined grid 8 2 4 Tips from the trainers themselves When conducting scans there are some extremely important items that need to be noted First of all it is crucial that you relax When you are tense you are putting too much pressure on yourself to do the scan correctly often resulting in errors e Newly buried targets are difficult to see Many users receive the equipment and the first thing they do is go out and bury an object When an object goes into the ground it changes the natural Signature of the soil and creates some kind of noise Usually the buried object has a weaker signature than the unnatural noise and therefor is not detectable So taken scan images will not Show the buried item but visualize the noisy area in blue colors After the item has been seasoned meaning it has been in the ground for a complete cycle of seasons usually a year the noise gets reduced and the signature of the buried object becomes visible again e Train on known targets In the training course at the factory we have several objects that have been buried for years just like real targets in the field These targets can be quickly and easily identified because they are not
27. age like in figure 2 6 will appear on your computer screen Now the drivers of your device are installed and you can transfer data to your PC i Neue Hardware gefunden x Die neue Hardware wurde installiert und kann jetzt verwendet werden Illustration 2 6 Install USB drivers Windows XP Step 6 OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 17 2 1 2 Uninstall USB drivers on Windows XP If you need to delete the USB open the device manager o represented in figure 2 7 drivers from your operating system because of a wrong installation please f Windows XP Therefore please click on Start gt control panel like Programme F Dokumente Systemsteuer Einstellungen ee eee coe eng i Netewerkyverbindungen Suchen Ro 4 Drucker und Faxger te Hilfe und Support Taskleiste und Startmen ChrisE abmelden Windows XP Professional Ja 2 7 Ausf hren Computer ausschalten Astat G Illustration 2 7 Uninstall USB drivers Windows XP Step 1 After that a dialog like in figure 2 8 appears There you can find the entry system and click twice on it E Systemsteuerung Datei Bearbeiten Ansicht Favoriten Extras Q zur ck gt Bi pe gt Ordner es x i Et Adresse Systemsteuerung Scanner und Kameras Schriftarten Software Sounds und Audioger te re F s TE we Sprachein
28. allieren empfohlen Software von einer Liste oder bestimmten Quelle installieren fur fortgeschrittene Benutzer DARPREPBFFERPFERPEELTELPERRITEPRREFELTERLFELTETPRERTEBEUFTENERETSRTLTELTERLERTEFTERTRERTRTELRLIRFFRTEETFTTTTETFTER Klicken Sie auf Weiter um den Yorgang fortzusetzen lt Zur ck Abbrechen Illustration 2 3 Install USB drivers Windows XP Step 3 In the next dialog window from figure 2 4 mark the entry No search select driver individually and click on Next Assistent f r das Suchen neuer Hardware Wahlen Sie die Such und Installationsoptionen gS Diese Quellen nach dem zutreffendsten Treiber durchsuchen Versenden Sie die Kontrollk stchen um die Standardsuche zu enaeitern oder einzuschr nken Lokale Pfade und fechselmedien sind in der Standardsuche mit einbegriffen Der zutreffendste Treiber wird installiert F wechselmedien durchsuchen Diskette ED 17 Folgende Duelle ebenfalls durchsuchen a Durchsuchen Yerwenden Sie diese Option um einen Geratetreiber aus einer Liste zu w hlen Es wird nicht garantiert dass der von Ihnen gew hlte Treiber der Hardware am besten entspricht lt Zur ck Abbrechen Illustration 2 4 Install USB drivers Windows XP Step 4 Another window will open represented in figure 2 5 where you have to select the driver file Therefore click on Data carrier Immediately another window appears where you click on the button Searc
29. arrying strap Control unit External power supply Telescopic rod assembly Supersensor T mount GPR probe 25 cm Illustration 6 1 Control unit with power supply and probe Via the display you can see the navigation menu and all recorded scans The horizontal antennas like the 25 cm GPR probe have to be connected via the T mount to the Telescopic rod assembly Vertical probes like the Super Sensor can simply be held in your hand OKM Ortungstechnik GmbH www okmmetaldetectors com Control Elements 43 6 1 Control Unit The control unit is the processing center of the eXp 4000 Via the control unit various functions can be selected all measured values can be recorded and stored 6 1 1 Front View Figure 6 2 shows the front side of the control unit with its control elements Display E 2 4 i es Fee nl er Oe es run Power switch Start button Carrying strap Next operating mode Connector Previous for joystick operating mode Illustration 6 2 Control unit front view Activate operating mode The Power switch is used to power on the device Prior to operating your unit connect the external Power Pack and turn it on The Start button is used to start a scan When in Manual mode it is also a secondary trigger to record a measurement The joystick Connector is used to connect the joystick to the device The joystick fullfils the same functions as the
30. ausgabe Taskleiste und Startmen Tastatur i ei Zeigt Informationen ber das Computersystem an 1 H Arbeitsplatz ve Illustration 2 8 Uninstall USB drivers Windows XP Step 2 The dialog from figure 2 9 appears on your screen Click on the tab hardware and after that the button device manager OKM Ortungstechnik GmbH www okmmetaldetectors com 18 Install Uninstall USB drivers on Windows Systemeigenschaften E ajx Spstemwiederherstellung Automatische Updates Remote Allgemein Computername Hardware Erweitert Hardware Assistent Mit dem Hardware Assistent konnen Sie Hardware installieren Hardware 42sistent Ta Gerate M anager Der Gerate M anager f hrt alle auf dem Computer installierten Hardwarekomponenten auf Yerwenden Sie den Gerate Manager um die Eigenschaften aller Komponenten zu ndern Treibersignierung Gerate M anager Hardwareprotile ber Hardwareprofile k nnen Sie verschiedene Hardware konfigurationen einrichten und speichern Hardwareprotile Abbrechen bernehmen Illustration 2 9 Uninstall USB drivers Windows XP Step 3 A list of devices like in figure 2 10 will be represented There you can find the entry USBController By clicking the plus symbol next of this entry all available USB devices will be shown CT PR Gerdte Manager Datei Aktion Ansicht age a Fl M use und ande
31. bH www okmmetaldetectors com Install Uninstall USB drivers on Windows 21 When the window from figure 2 14 is visible insert the software CD with the USB drivers into your CD drive and click on the Next button Windows will now search for the correct USB drivers automatically Found New Hardware eXp 4000 Insert the disc that came with your eXp 4000 F you have the disc that came with your device insert it now Windows will automatically search the disc for driver software Idon t have the disc Show me other options Illustration 2 14 Install USB drivers Windows Vista Step 3 When the installation has finished the completion screen from figure 2 15 is displayed Press Close to close this window k mi Found New Hardware ORM Quick Link The software for this device has been successfully installed Windows has finished installing the driver software for this device OKM Quick Link Illustration 2 15 Install USB drivers Windows Vista Step 4 Now you have completed the installation of the USB drivers in Windows Vista which will be confirmed by presenting the message from figure 2 16 x OKM Quick Link Device driver software installed successfully bo ty i ee 10 46 AM Illustration 2 16 Install USB drivers Windows Vista Step 5 OKM Ortungstechnik GmbH www okmmetaldetectors com 22 Install Uninstall USB drivers on Windows 2 2
32. bject Please try to capture the complete object which means you should measure beyond the edges of the object Repeat this measurement a few times to get a clear signature of the object There are 3 different signatures from which you can recognize a specific characteristic of any target Ferromagnetic metals Ferromagnetic targets have a positive negative signature Illustration 7 12 Signature of a ferromagnetic metal target The figure 7 12 shows a typical signature of a ferromagnetic metal like iron The signature includes a positive red and a negative blue amplitude When looking closely you can see even 2 ferromagnetic signatures The first signature starts with a positive amplitude and the second signature starts with a OKM Ortungstechnik GmbH www okmmetaldetectors com Operating Modes 55 negative amplitude The order is not important it depends on the direction of movement of the Supersensor If you keep moving the probe from one side to another these 2 signatures will change continuously Take care to move the Supersensor slowly and at the same height above the ground and above a detected object to get a clear signature Non ferromagnetic metals Non ferrous targets have a pure positive Signature Illustration 7 13 Signature of a non ferromagnetic metal target The figure 7 13 represents a signature of a non ferrous target You can recognize that there is only a positive amplitude red Additionally
33. can it is important to not only make note of how many impulses are being used but to get a clear picture of what you are scanning it is very important to watch your speed Every scan line Should be measured at the same speed as the previous line Figure 8 5 shows what can happen if you walk at different speeds during your scan Start of scanning path End of scanning path Parallel scanning Zig Zag scanning Figure 8 5 Different walking speeds during scanning Using a different walking speed in the scanning paths will cause displacements in the scanning path As a matter of fact a target can get cut into several smaller items or completely lost because it was missed Later when the data is downloaded for further analysis speed errors can make a target completely unidentifiable and may be discarded In general the following rule is valid Keep scans at practical sizes where you can see the beginning and stop lines and can comfortably traverse an area to keep your speed and the distances reasonable 8 2 Special advices for field procedure There are some aspects which you should take note of when conducting scans In principle a scan is only as good as the path that was taken Making errors while scanning will show up in the final graphical representation also as an error This will cause frustration and lost time Before you start with a measurement in the field you should think of what you are looking for and if the sele
34. could not install any drivers for your device successfully AL Device driver software was not successfully installed gt Click here for details 11 58 AM it B i a le apo Illustration 2 27 Install USB drivers on Windows 7 Step 2 Press the Windows 7 start button to bring up the start menu and select Control Panel as shown in figure 2 26 Snipping Tool 2 User eS Ta u 5 J Documents Getting Started Pictures Windows Media Center Music le Calculator er Im ames f aa Sticky Motes a Computer 4 Wink Control Panel Remote Desktop Connection Devices and Printers Au Magnifier Default Programs sj Solitaire Help and Support gt All Programs Shut down mm Illustration 2 28 Install USB drivers on Windows 7 Step 3 OKM Ortungstechnik GmbH www okmmetaldetectors com 28 Install Uninstall USB drivers on Windows This will open up the control panel window as shown in figure 2 29 From the control panel window you have to select Hardware and Sound System and Security Review your computer s status Back up your computer Find and fix problems Network and Internet View network status and tasks Choose homegroup and sharing options Hardware and Sound View devices and printers Add a device Programs Uninstall a program View by Category User Accounts and Family Safety Add or remove user accounts
35. cted area is suitable Measuring without a plan usually will produce unacceptable results Please consider the following advice e What are you looking for graves tunnel buried objects This question has direct effects on how a scan is conducted If you are looking for larger targets the distance between the single measure points and scanning paths can be larger as if you are looking for small targets e Inform yourself about the area where you are searching Does it make sense to detect here Are there historical references which confirms your speculation What type of soil is on this area Are there good conditions for data recording Is it allowed to search at this place e g private property OKM Ortungstechnik GmbH www okmmetaldetectors com 62 Field procedure e Your first measurement in an unknown area has to be large enough to get representative values All further control measurements should be adjusted individually e What is the form of the object you search If you are looking for an angular metal box the identified object in your graphic should have a form according to this e To get better values concerning depth measurements the object has to be in the center of the graphic which means it has to be framed by normal reference values normal ground If the object is on the side of the graphic and not totally visible an estimated depth measurement is not possible and also measurement of size and form
36. e Browse Scans function with the OK key you will see a list of the stored scans as represented in figure 7 8 Select the measurement which you like to see with the keys W and For the 20060124102822 Back To Main Menu Illustration 7 8 Select Stored Measurement selected measurement the following options represented in figure 7 9 are provided Delete Scan Image Cancel Illustration 7 9 Submenu Browse Scans www okmmetaldetectors com 52 Operating Modes View Scan Image The selected measurement will be displayed once again Press any key to go back to the selection menu Delete Scan Image The current selected measurement will be deleted if you confirm the following message with Yes Following you will go back to the menu Ground Scan Back To Ground Scan Menu You go back to menu Ground Scan OKM Ortungstechnik GmbH www okmmetaldetectors com Operating Modes 53 7 3 Metal Detector To use this operating mode you have to connect the optional DDV system first This detector is specialized to find small objects e g coins which are located near to the surface Magnetometer Ground Scan Discrimination AH Exit From 2 18 v1 8 I AA E 25 A eh 2 UP DHH Cancel t OH Zero Value Illustration 7 10 Metal Detector Also with this detector you have the possibility to discriminate between different metals So for example you can find out if an object is gold silver or iron
37. e are different aspects which Should be considered These are some considerations e the length of your measured area and e the size of the objects you are searching for A preferable distance between two impulses is about 15 cm to 30 cm The smaller the distance between two impulses is the more exactly the graphical representation will be If you are looking for small objects you have to select a smaller distance for big objects you can increase the distance between the impulses Figure 8 3 shows the effects of the distance and the number of impulses per scanning path for some objects ee Ua Figure 8 3 Effects of changing the number of impulses and their distance Figure 8 4 shows the difference between very few impulses left side and much more impulses right Side on the same length of scanning path Therefor the second record right side shows much more details and also smaller objects can be seen Figure 8 4 Comparison of low and high number of impulses Do not hesitate to record more measurements with different numbers of impulses For example you can scan a large area before doing a second detailed precision measurement Especially if searching for OKM Ortungstechnik GmbH www okmmetaldetectors com Field procedure 61 bigger objects you can proceed like this With this manner you can measure a larger area very quickly and afterward you make new scans localizing the suspect targets When conducting a s
38. e distance between the paths the more accurate your scans will be When you are conducting your first scans the lines should not be to close together to locate possible targets 8 1 2 Regulation of the number of impulses per scanning path It is possible to select the number of impulses before starting the measurement or selecting the automatic mode Auto to adjust the number of measure points after finishing the first scanning path When the number of measure points has been configured the device will stop automatically when this number has been reached and waits for the start of the new scanning path In the automatic mode you should stop the measurement of the first scanning path by yourself by pressing the appropriate button as soon as you have reached the end of the first scanning path This effective amount of measure points will be used for all further scanning paths of this measurement Starting from the second scanning path the device now stops automatically after the assumed number of impulses has been reached OKM Ortungstechnik GmbH www okmmetaldetectors com 60 Field procedure Keep in mind the number of impulses which you have recorded per scanning path This amount Should be entered later in the software program when transferring the data to a PC to receive all measured data correctly from your measuring instrument There is no special rule for selecting the right number of impulses But ther
39. e er ee O minimum 1 5 GHz ED ROM DIN ee EIERN ee minimum 4x POr Dal Trans Son en ee nea sc nee ER ee ee see USB PC IIOP sorreraren r E E minimum 50 MB Working Memory RAM zusesesessssssssssnsennnsenennnnenennnnnennnnsnensnnnnnnnnnnsnnnsnsnnsnnsensnnsnnsnnsnn minimum 256 MB STF og DT ee ee ea TE minimum 128 MB OpenGL compatible Operating System ii r aE RNE Windows XP Windows Vista Windows 7 OKM Ortungstechnik GmbH www okmmetaldetectors com Scope of Delivery 36 Scope of Delivery In the following section you can find all standard equipment The scope of delivery can be different in some circumstances because of some optional accessories which should not be included in the basic equipment Control unit incl carrying strap Headphones Telescopic rod assembly for GPR antenna Power Pack with charger and travel adapter GPR antenna 25 cm Joystick User s manual Carrying case 3D Software Visualizer 3D USB cable Super sensor PPP YP PP PP YP PP PP YP PP PP PN FP PP PrP YP PN FP PP PP PP PP Antenna for metal discrimination DDV system GPR antenna 50 cm GPR antenna 75 cm GPR antenna 100 cm Antenna for tunnel detection PP YP PP HE FS Thermoscan Table 1 Scope of delivery OKM Ortungstechnik GmbH www okmmetaldetectors com CHAPTER 5 Assembly This section explains how to assemble the eXp 4000 and to prepare the unit for operation 38 Assembly Befo
40. e this mode you can actually move quite quickly to clear a field of easily identified metallic objects Most of the time when your target may be of a newer nature or is located in an area where there is a lot of modern construction this is the first choice to identify potentially Hot targets A hot target can be debris like cans nails screws old automobile parts etc These should be cleared first The magnetometer measures usually only near to the surface for quick hunts OKM Ortungstechnik GmbH www okmmetaldetectors com 48 Operating Modes 7 2 Ground Scan This operating mode allows you to do a measurement with graphical representation whereby all measured values will be stored in the internal memory of the device Also you have the possibility to recall and see previous stored graphics This mode can be used with all antennas except the DDV system The Ground Scan mode is your primary function This is the mode where you are going to find the targets and locate areas of disturbed soils When something is buried then whoever buried it had to dig a hole Look for the disturbance in the soil first If a hole was created at 4 feet 1 5m deep after a couple of seasons the hole will appear to be over 6 ft 2m in diameter at the surface Start with a scan that has an impulse approximately every 1 to 2 feet 40cm 60cm forward and to the sides Don t go too fine on the first scans until you have a possible anomaly Look for
41. ects off of your person like cellular telephones keys jewelry etc Do not wear steel toe boots 1 2 4 Voltage The power supply should not be outside the indicated range of values Use only approved chargers batteries and rechargeable batteries which are included in the scope of delivery Never use the 115 230 Volt mains supply OKM Ortungstechnik GmbH www okmmetaldetectors com 10 Introduction 1 2 5 Data safety Data errors can occur if e the range of the sender module has been exceeded e the power supply of the device or the batteries are too low e the cables are too long e the unit is operating to close to devices which sends out disturbances or e atmospheric conditions electrical storms lightning etc 1 3 Maintenance and Services In this section you will learn how to maintain your measuring instrument with all included accessories to keep it in good condition a long time and to get good measuring results The following list indicates what you absolutely should avoid e penetrating water e strong dirt and dust deposits e hard impacts e strong magnetic fields e high and long lasting heat effect To clean your device please use a dry soft rag To avoid any damage you should transport the device and accessories always in the appropriate carrying cases Prior to using your eXp 4000 please be sure that all batteries and accumulators are fully charged Also allow the batteries to comp
42. eeresersseeeeeeeessesereeeeee 29 Install USB drivers on Windows 7 Step 8 cece cece sc ecenencecencncecensecesenseceesensensenseenes 30 Install USB drivers on Windows 7 Step 9 ec ecc cece sc eceecececencncecensecesenseceessensentenseenes 30 Install USB drivers on Windows 7 Step 10 ec ccc cc nsec ec cecececcecececeeceensenseesenseenes 31 Uninstall USB drivers on Windows 7 Step 1 ou ec ececcccececeneesecentecesenseceneeeeeengens 32 Uninstall USB drivers on Windows 7 Step 2 eeeesesessesessssessennnnsnennesennnnnsennenenennennennenn 32 CORNEELOM OF DFO C ee ee a REN EEE 38 Connection of Power Pack uuosuuueunesennnann una 38 Connection of headphones cece ececencecececencecenenceceneececeneeeesessesenseessensenseessensecseenes 38 Connection DE JOVSUCI ee 39 Control unit with power supply and probe cece cecc sence cecececeeeenensenseaeeseeseeseenensens 42 CONU OL UN TORE VAC W soc ee sans 43 GCONLL OL UNI ROAD VIEW ae Renee 44 Magnetometer Main Menu Representation of Values ccccececececeneeeececececeeeneeeeaees 47 CS TO AW ee EETA A E T een 48 OKM Ortungstechnik GmbH www okmmetaldetectors com IN stration 7 9 Ground Scan SUD MENU asus ea 48 Illustration 7 4 Ground Scan Parameter evosadsenedavoedenesrnimebense EE EIEE aaaea 49 lust ration 7 05 Zig Zag Or Para Wen seen anne ee es Bere ee 49 Illustration 7 6 Start first scan line susanne an aa ne een 50 I
43. en minimize the distance to the ground You are turning the discriminator during ground balance Only if you are doing a correct soil reconciliation the functionality of discrimination can be guaranteed OKM Ortungstechnik GmbH www okmmetaldetectors com CHAP al en 2 10 Error Messages In this chapter you will find possible error messages which can appear during the work with the device 72 Error Messages In case you are scanning very large areas in the operating mode Ground Scan the stored files will also be very large which could fill up the internal memory completely As soon as the free memory cell is less than 20 the message shown in figure 10 1 will appear Illustration 10 1 Only a small amount of memory available If there is no more free memory available you will see a message like in figure 10 2 You can free memory space by transfering all stored data via software to your computer or by selecting the option Empty Memory to delete all stored data without having transferred them to your computer Illustration 10 2 No free memory available If message 10 3 appears the device cannot control the operating voltage This also means it cannot warn you in case of a low status of the battery Also the automatic shutdown of the device may be affected It is adviced to let the device check from the manufacturer to avoid further damages Illus
44. faults ground water and other non metallic objects Then of course this equipment is best suited at detecting sepulchers treasure buried utilities tanks and the like The eXp 4000 is able to locate document and analyze buried objects within various structures and vessels non intrusively without having to excavate the area Using EMSR is particularly useful in areas where detection is a must and excavation is not possible The facile and flexible handling of the eXp 4000 can easily and quickly give reproducible results With our team of specialists we guarantee that our products are under recurrent control Our specialists try to implement new developments in terms of further quality improvements for you By purchasing or using one of our products we cannot guarantee that during the course of your research that you will be successful and have a find The recognition of hidden and buried objects depends on a huge number of factors As you well may know there are different soil types all over the world with different levels of natural attenuation Variable soil properties can and will hamper and alter ultimate scan measurements Areas where there is an extreme amount of ground water varying clays sands and wet soils making scanning more difficult and may reduce the maximum depth capabilities of any and all detection equipment regardless of make or model For more information regarding where this equipment has been used and operated please
45. h Then select the file OKM_LE INF which you can find in the directory drivers usb_cable of your software CD Afterwards you have to click on Open OK and Next to start the installation of the files OKM Ortungstechnik GmbH www okmmetaldetectors com 16 Install Uninstall USB drivers on Windows Assistent f r das Suchen neuer Hardware Wahlen Sie den fur diese Hardware zu installierenden Ger tetreiber ne Wahlen Sie den Hersteller und das Modell der Hardwarekomponente und klicken Sie auf fe Wetter Klicken Sie auf Datentr ger wenn Sie ber einen Datentr ger verf gen der den erforderlichen Treiber enth lt 7 Kompatible Hardware anzeigen Modell Installation von Datentr ger x Legen Sie den Installationsdatentrager des Herstellers Ok a ein und stellen Sie sicher dass weiter unten das richtige d l anbmark SH ist i aea Datei suchen ajx Datentr ger Suchen im E usb cable wi fr OKM_LE I y Zuletzt verwendete Dokumente Desktop Eigene Dateien i Abbrechen E E Arbeitsplatz EA 3 Diskette A Durchsuchen os SYSTEM C Ta DATEN D x RECOVER E Cy DYD Laufwerk F 3 CD Aw Laufmerk G E drivers usb cable __ttnen Dateiname i pe Offnen 4 Gemeinsame Dokumente ffnen Dateityp ET Eigene Dateien F Abbrechen Hetzwerkumgebung Z Illustration 2 5 Install USB drivers Windows XP Step 5 After successful installation of the driver a mess
46. he front of your device you can select and confirm your desired operating mode OKM Ortungstechnik GmbH www okmmetaldetectors com Operating Modes 47 7 1 Magnetometer By selecting the Magnetometer mode from the main menu you can scan the sub surface for ferromagnetic targets and areas of the soil with a high iron content Also you may view the oscilloscope output on the monitor to be able to identify ferromagnetic materials in the ground Ground Scan Discrimination Al Metal Detector Empty Memory Exit Beeorw 2 18 VI B Kaa el UF DOWH Cancel 3 OH Zero Value Illustration 7 1 Magnetometer Main Menu Representation of Values The Magnetomer mode can be used with all the antennas except the DDV system As soon as you confirm the operating mode Magnetometer the integrated magnetometer will be adjusted to the current ground value of the place where it is situated at that moment During the initialization process the message Ground Balance Please Wait appears on the display Only after this message disappears can you start your search When powering on the unit above a neutral soil all metallic signatures will be shown in upward spikes If by mistake you start the unit above a metal target all like metals will not be recognized To re balance the Magnetometer press the OK button while staying on a neutral place To exit the Magnetometer mode press the or A to return to the main menu When you us
47. ield procedure 59 Start of scanning path End of scanning path Parallel scanning Zig Zag scanning Figure 8 2 Scan modes to measure an area Doing the scan in Parallel mode you will start on the bottom right corner of your scan area point to walk and record a scan path towards the upper right corner of the area After recording the first line you should walk back to the starting point and move to the left of the first scan line to start the scan path 2 point to start there the second scanning path In this way all other paths will be scanned until you have reached the left side of your measure area Doing the scan in Zig Zag mode you will start also from the bottom right side of your measure area point to walk and record a scanning path towards the right upper corner of the measure area Different from the parallel measurement you should continue recording data while walking back the second scanning path So you go to the starting point of the second scanning path point and scan in the opposite direction In this way all other paths will be scanned in the scan mode Zig Zag until you have reached the left side of your measure area The distance between the scanning paths should be consistent during one measurement but can vary from measure area to measure area If you mostly look for smaller targets than you should also select a smaller distance between the lines A standard rule is The smaller th
48. ions such as rocker fuses acid fuses and ball fuses Those components have been rusting away in the course of time and the slightest movement may cause parts of them to break and be triggered Even seemingly harmless objects such as cartridges or large ammunition are anything but that Explosives may have become crystalline over time that is sugar like crystals have formed Moving such an object may cause those crystals to produce friction leading to an explosion If you come across such relics mark the place and do not fail to report the find to the police Such objects always pose a danger to the life of hikers walkers farmers children and animals OKM Ortungstechnik GmbH www okmmetaldetectors com APTER 2 Install Uninstall USB drivers on Windows In this chapter you will learn how to install the USB drivers that are necessary to transfer data from the machine to your computer software Please make sure to read the proper section appropriate to your Windows operating system 14 Install Uninstall USB drivers on Windows 2 1 Windows XP The instructions in this section are only valid for Windows XP 2 1 1 Install USB drivers on Windows XP The installation of the USB drivers in Windows XP is relatively simple After you have connected the device with your computer switch it on and the message from figure 2 1 appears on your screen i Neue Hardware gefunden x exp 3000
49. l Notes Being an electronic device the eXp 4000 has to be treated with caution and treated with care as with any electronic device Any failure to observe the safety precautions given or any use for purposes other than the ones it is designed for may result in damage or destruction of the processing unit and or its accessories or connected components The device has a built in anti tampering module which will destroy the unit if it is improperly opened There are no end user serviceable parts on the inside of the unit 1 2 2 Possible Health Hazards If used properly this device normally does not pose any health hazards According to current scientific knowledge the high frequency signals are not harmful to the human body on account of their low power 1 2 3 Surrounding Area When moving this unit from a cold place to a warmer place watch out for condensation Do not immediately operate the unit until any possible condensation could have evaporated The unit is not weather proof and water or condensation can destroy the unit Avoid strong magnetic fields which may occur in places where there are large electric motors or unshielded loudspeakers Try to avoid using this equipment within 50 meters 150 ft of this type of equipment Metallic objects on the ground such as cans tin nails screws or debris can influence your scan data and present negative results regarding your scan data Also it is a good habit to remove any metallic obj
50. l USB drivers on Windows 7 Step 9 When the installation has finished the completion screen from figure 2 32 is displayed Press Close to close this window and go back to the Device Manager OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 31 The Device Manager will now show a device under Universal Serial Bus Controllers indicated in the screenshot below as OKM Quick Link Da fi i File Action View Help e m el ie 4 a user PE gt gi Computer b cq Disk drives Ey Display adapters DVD CD ROM drives Ca IDE ATA ATAPI controllers 5 Keyboards A Mice and other pointing devices ME Monitors b EP Network adapters bA Ports COM amp LPT b a Processors b Sound video and game controllers b e Storage controllers pgi System devices ae 7 Universal Serial Bus controllers 9 OKM Quick Link en F Standard Enhanced PCI to USB Host Controller u 7 Standard OpenHCD USB Host Controller 9 USB Root Hub Illustration 2 35 Install USB drivers on Windows 7 Step 10 Tr The USB drivers are correctly installed now and you can close the Device Manager window OKM Ortungstechnik GmbH www okmmetaldetectors com 32 Install Uninstall USB drivers on Windows 2 3 2 Uninstall USB drivers on Windows 7 If you need to delete the USB drivers from your Windows 7 operating system please open up the Device Manager as described in the previous s
51. lained in this following section 1 The indications from table 2 concern the use in normal type of soil In extreme conditions mineralisation salt deposits they can variate from this normal value OKM Ortungstechnik GmbH www okmmetaldetectors com 9Optional Equipment 70 9 2 3 Ground Balance A correct soil reconcilation Ground Balance is absolutely necessary that the adjusted discrimination can work properly If the soil reconciliation is not done correctly the operation of the device and the integrated discriminator cannot work properly In the following section you can find a list of all necessary working procedures to do a correct soil reconciliation 1 Power on the eXp 4000 and connect the DDV system 2 Adjust the discriminator on the material you like see previous section 3 Put the device with coil approx 10 cm above the ground 4 Select the operating mode Metal Detector and confirm it If you hear an acoustic signal from the DDV system after these indications then the ground balance is not finished correctly Repeat these steps until there is no acoustic signal from the metal detector The following causes can prevent a correct soil reconciliation You are staying above a metalic object You confirm the operating mode Metal Detector without holding the coil directly above the ground During the confirmation of the operating mode Metal Detector you are holding the coil to high and th
52. letely discharge before recharging them regardless if you are working with the external battery or with internal accumulators This way your batteries will have a long and durable life To charge the external and internal batteries use only the approved chargers which are part of our scope of delivery 1 4 Danger of Explosion during Excavation Unfortunately the last two world wars also made the ground in many places of the world a potentially explosive scrap heap A host of those lethal relics are still buried in the ground Do not start digging and hacking for an object wildly when you receive a signal of a piece of metal from your device Firstly you might indeed cause irreparable damage to a truly rare find and secondly there is a chance that the object reacts in an insulted way and strikes back Note the color of the ground close to the surface A red or reddish color of the ground is an indicator of rust traces As regards the finds themselves you should definitely pay attention to their shape Curved OKM Ortungstechnik GmbH www okmmetaldetectors com Introduction 11 or round objects should be a sign of alarm especially if buttons rings or little pegs can be identified or felt The same applies to recognizable ammunition or bullets and shells Leave that stuff where it is do not touch anything and most importantly do not take any of it home with you The killing machines of war made use of diabolical invent
53. llustration 7 7 Graphical Representation of a Measurement in Operating Mode Ground Scan 50 Illustration 7 8 Select Stored Measurement ccccccecececececesenencecececececeaeseeeesecececeseseseeceeceesessessensenss 51 Illustration 7 9 Submenu Browse Scans cccccccecscscececececeseseesecececeeceseesesessceeeseneseeaeeceeceecessensessessess 51 Illustration 7 10 Metal Detector esesesesenessnsnononunnnonennnununenunenenunnnnnnnnnnnnnnnunununnnnnunnnnssnnsnsnnnsnnnnn 32 Hlostration 7 112 Discrimination esse Renee 32 Illustration 7 12 Signature of a ferromagnetic metal target 2s2sssssssssssnensnenennnenenennsnsnnnnnnnsn nenn 53 Illustration 7 13 Signature of a non ferromagnetic metal target sssessessessressesseesseeesssseeeesssseeesso 53 Illustration 7 14 Signature of a non metallic target sssessessesseseessesesssesesseesesseesessessesoeseeseeseeessseeeso 53 TIES TRAIT 7 13 Empty ECO seinoria ENTE 54 Hacia onr AO E Eae E ee ee 54 Illustration 9 1 Position of Super Sensor ssssssesesesreserssreseessesssessesssessesseessessorsoeesssssreesssssreeesssereeesso 66 Illustration 9 2 Control Elements of the Detector 22020s0ssesensonenennnenenennenennnnnnnennsnenennsnnsnnsnnenn 67 Illustration 9 3 Calibration of the DDV system step 1 ersesesssenesensesensnnnnnnnnenenennenenennnenennnnnsnnsneenn 68 Illustration 9 4 Calibration
54. mputer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings gt Browse my computer for driver software Locate and install driver software manually Cancel Illustration 2 32 Install USB drivers on Windows 7 Step 7 OKM Ortungstechnik GmbH www okmmetaldetectors com 30 Install Uninstall USB drivers on Windows In the address box put the exact location where the drivers have been saved to Usally this may be your software CD or a folder on the PC if you downloaded the drivers from our website It is not necessarily the exact same location as shown in the screenshot of figure 2 31 Som Update Driver Software eXp 4000 Browse for driver software on your computer Search for driver software in this location D Drivers USB_Cable W Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device Illustration 2 33 Install USB drivers on Windows 7 Step 8 After entering the drivers location select Next to start the installation Update Driver Software OKM Quick Link Windows has successfully updated your driver software Windows has finished installing the driver software for this device OKM Quick Link Illustration 2 34 Instal
55. nation Metal Detector Empty Memory Peso 2 18 v1 8 4 64 E 2561 eh 2 Illustration 7 16 Exit Please wait until the device has powered itself off After the device is off you can power off the external power supply 7 7 Thermograph This operating mode is only visible and usable if the optional device FS Thermoscan is connected Detailed information about this functionality is available in the user s manual of FS Thermoscan 7 8 Thermo Scan This operating mode is only visible and usable if the optional device FS Thermoscan is connected Detailed information about this functionality is available in the user s manual of FS Thermoscan OKM Ortungstechnik GmbH www okmmetaldetectors com 28 HAP I 1 Field procedure This chapter gives practical instructions about the general procedure of scanning an area The different scanning methods and procedures will be explained in detail 58 Field procedure 8 1 General scanning procedure In general every scan always starts on the bottom right corner of your scan area Starting from this point you should walk scan path by scan path whereby every following path is situated on the left side of its previous path During walking these lines the measurement values will be recorded and depending on the selected operating mode either transferred directly to a computer or saved into the memory of the device
56. nge The darker the more iron it will have in it o Sand is usually very clear and easy to hunt in There are two factors of sand that need to be noted Sand where the ground water is very shallow meaning that the ground water is usually just a couple of meters from the surface or desert sand where it is very arid In desert sand the targets can be situated 3x deeper than indicated o Farmland is another area to take note of In modern farms so many nutrients and fertilizers are introduced creating an unnatural area of mineralization o Rocky mountainous areas Areas with many mountains are also riddled with patches of mineralization Mountainous areas are created from faults in the earth and this is probably the biggest area for natural treasures as well as mineralization OKM Ortungstechnik GmbH www okmmetaldetectors com HAP Optional Equipment Here you can find additional information on accessories that can compliment the basic unit Keep in mind that the mentioned accessories are not included in the normal scope of delivery 66 Optional Equipment 9 1 Super Sensor The Super Sensor is a hig hresolution antenna which is specially adjusted to detect metals Yet it is also possible to recognize larger voids with this antenna A particular characteristic is to distinguish ferrous metals from nonferrous metals This discrimination is possible in the operating mode Discrimination Compared t
57. ntroller Standard OpenHCD USB Host Controller USB Composite Device USB Mass Storage Device USB Root Hub USB Root Hub USB Root Hub USB Root Hub Illustration 2 23 Update USB drivers on Windows Vista Step 7 The USB drivers are correctly updated installed now and you can close the Device Manager window OKM Ortungstechnik GmbH www okmmetaldetectors com 26 Install Uninstall USB drivers on Windows 2 2 3 Uninstall USB drivers on Windows Vista If you need to delete the USB drivers from your Windows Vista operating system please open up the Device Manager as described in the previous subsection Installed devices can be removed using the Device Manager by simply right clicking on the mouse and selecting Uninstall This will delete the associated registry entries for that device only gay Device Manager File Action View Help gt mE BAR eRe 5 5 Imaging devices He Keyboards a Mice and other pointing devices a Modems al Monitors ces Network adapters ce Portable Devices a Ports COM amp LPT af Processors H Sound video and game controllers a Storage controllers jil System devices H g Universal Serial Bus controllers Realtek USB Update Driver Software standard En Disable Standard Enh Standard Ope Standard Ope Scan for hardware changes USB Compos USB Mass Sta Properties USB Root Hub USB Root Hub USB Root Hub USB Root Hub Uninstall
58. o the standard Horizontal GPR antennas the Super Sensor can find much smaller and deeper situated metal objects 9 1 1 Usage The Super Sensor can be used in the following operating modes e Magnetometer e Ground Scan e Discrimination To use the Super Sensor with the device you just have to connect it to the main unit Therefore you have to plug in the connector of the antenna in the appropriate input of the device Hold the antenna always vertical to the ground in your hand whereby the cable should come out at the upper end of the antenna The figure 9 1 shows how the Super Sensor has to be hold in a correct way Illustration 9 1 Position of Super Sensor The Super Sensor should not be swinged nor moved up and down during the measurement The more even you hold the antenna the better will be your measured graphical results The distance between the ground and lower part of the antenna should be about 10 cm but can be enlarged depending on the terrain conditions The orientation of the antenna should not be changed during the complete measurement OKM Ortungstechnik GmbH www okmmetaldetectors com 67 Optional Equipment 9 2 DDV system With the DDV system Disc Detector Visualization System a powerful metal detector is on your disposal which not only supports your underground research with a visual representation but also offers you various filter possibilities ra X ry
59. ple After you have connected the device with your computer switch it on and the message from figure 2 12 appears on your screen Click on Locate and install driver software recommended Found New Hardware x Windows needs to install driver software for your eXp 4000 Locate and install driver software recommended Windows will quide you through the process of installing driver software for your device gt Ask me again later Windows will ask again the next time you plug in your device or log on Don t show this message again for this device Your device will not function until you install driver software Illustration 2 12 Install USB drivers Windows Vista Step 1 At the next window shown in figure 2 13 click on Don t search online k Found New Hardware eXp 4000 P pP Allow Windows to search online for driver software for your eXp 4000 Yes always search online recommended Windows will automatically search for the latest drivers and applications for your hardware and download them to your computer Yes search online this time only Windows will search for the latest drivers and applications for this device and download them to your computer Don t search online Your device may not function properly until you get the latest software Please read Microsoft s privacy statement Illustration 2 13 Install USB drivers Windows Vista Step 2 OKM Ortungstechnik Gm
60. re Zeigeger te co Modems E z Monitore Ee Netzwerkadapter Ee I Prozessoren E Y Systemger te Higa Tastaturen een USB Controller EOKR1 Quick Link Standard USE Hub LISE Root Hub LISE Root Hub VTA Rev 5 oder h her USB universeller Hostcontroller YIA Rev 5 oder h her USB universeller Hostcontroller Illustration 2 10 Uninstall USB drivers Windows XP Step 4 Mark the device which you like to delete which means eXp 4000 Additionally the device may be listed as OKM Quick Link Then click on the button Alternatively you can select the entry Uninstall in the menu Action OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 19 Entfernen des Ger ts best tigen a ajx fe OKM Quick Link Warnung Sie sind dabei das Ger t aus der Systemkonfiguration zu deinstallieren Abbrechen Illustration 2 11 Uninstall USB drivers Windows XP Step 5 The dialog from figure 2 11 appears Click there on the button OK Now all drivers will be deleted from your computer If needed you can now install the USB driver again correctly OKM Ortungstechnik GmbH www okmmetaldetectors com 20 Install Uninstall USB drivers on Windows 2 2 Windows Vista The instructions in this section are only valid for the Windows Vista operating system 2 2 1 Install USB drivers on Windows Vista The installation of the USB drivers in Windows Vista is relatively sim
61. re you can use the device eXp 4000 for a field measurement you should do some preparations Please make notes to the following steps Step 1 Connect the probe which you would like to use to the control unit Regardless of which probe you are using you will always use the same plug for each probe You can only use one probe at a time for one measurement Illustration 5 1 Connection of probe Step 2 Now you can connect the Power Pack to the control unit After powering on the Power Pack you can put it in your pocket Now you should power on the device by using the Power On Off button Illustration 5 2 Connection of Power Pack Step 3 The headphones are necessary to hear the acoustic output of the device But you are also able to scan the field without connecting the headphones Illustration 5 3 Connection of headphones OKM Ortungstechnik GmbH www okmmetaldetectors com Assembly 39 Step 4 If you are going to be conducting a scan in Manual mode plug in the joystick to the control unit Illustration 5 4 Connection of joystick OKM Ortungstechnik GmbH www okmmetaldetectors com 4APTER 6 Control Elements In this section you will learn more about the fundamental use of all control elements for the eXp 4000 measuring instrument All connections inputs and outputs are explained in detail 42 Control Elements Headphones C
62. s HE System d H F Universal Properties Launches the Update Driver Software Wizard for the selected device Illustration 2 19 Update USB drivers on Windows Vista Step 3 From the displayed menu select Update Driver Software which then displays the option for an automatic or manual search Select the second option to browse manually amp Update Driver Software eXp 4000 How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device gt Browse my computer for driver software Locate and install driver software manually Illustration 2 20 Update USB drivers on Windows Vista Step 4 OKM Ortungstechnik GmbH www okmmetaldetectors com 24 Install Uninstall USB drivers on Windows In the address box put the exact location where the drivers have been saved to Usally this may be your software CD or a folder on the PC if you downloaded the drivers from our website It is not necessarily the exact same location as shown in the screenshot of figure 2 28 J Update Driver Software eXp 4000 Browse for driver software on your computer Search for driver software in this location E Drivers USB_Cable Include subfolders gt Let me pick from a list of device drivers on my computer This list will sho
63. s for any user i Add or remove user accounts Appearance and Personalization Change desktop background Customize colors Adjust screen resolution Clock Language and Region Change keyboards or other input methods Change display language Ease of Access Let Windows suggest settings Optimize visual display Additional Options Illustration 2 18 Update USB drivers on Windows Vista Step 2 OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 23 In the Device Manager see figure 2 27 there will be a device under Other devices with a yellow warning symbol to indicate a problem i e no driver installed If the drivers has been installed already it will show up under Universal Serial Port Controllers The text next to this device will depend on the device attached In this example the device was an eXp 4000 device Right click on the device eXp 4000 in this example to bring up a menu as shown below 4 Device Manager foro bs x File Action View Help ASN e eRe Ea OKM PC mA Batteries Ei Computer H a Disk drives cM Display adapters af DVD CD ROM drives a ga Human Interface Devices 3 IDE ATA ATAPI controllers Imaging devices H a keyboards a Mice and other pointing devices a Modems ER Monitors H E Network adapters al Other devices exp 4000 Update Driver Software i Ports CQ Disable BMI Processor Uninstall Es Sound vi rie Storage c Scan for hardware change
64. ted to the current length of your search line During the first line the device will read values regulary without stopping When you want to finish your first line you have to press the OK key to stop the measuring process of the current line The device will store the number of impulses and use it for all further scan lines on the same scan By selecting the value 10 20 or 50 you can preset the number of impulses you need in one measured line OKM Ortungstechnik GmbH www okmmetaldetectors com 50 Operating Modes e Scan Mode Parallel Zig Zag Scan Mode defines the method of scanning an area In the Parallel mode measurement starts always from the starting line whereas in the Zig Zag mode measurements starts at the end of Illustration 7 5 Zig Zag or Parallel the line which was scanned before like represented in figure 7 5 In the last scanning method Zig Zag you have to take care not to change the orientation of the antenna which means if the white arrow on the side of the probe shows to north direction for example it has to show to north direction in every measured line Select the parameter which you want to change with the keys W and 4 until it is highlighted in red color Now press the OK key The marking will change so that only the current value is highlighted in red color Now you can change the value of the selected parameter by using the keys WV and To finish this process you have to press the OK key again
65. the holes Usually without a hole you could be looking at mineralization Discrimination Peso 2 18 Illustration 7 2 Ground Scan In the first submenu which is shown in figure 7 3 you can choose between the following alternatives New Scan Set up and record a new graphic Browse Scans See or delete stored graphics Back To Main Menu Finish Ground Scan and go back to the main menu OKM Ortungstechnik GmbH www okmmetaldetectors com Operating Modes 49 Browse Scans Back To Main Menu Illustration 7 3 Ground Scan Submenu 7 2 1 New Scan After activating this operating mode you have the possibility to adjust certain settings There are different parameters which influence the measurement In figure 7 4 you can see the corresponding submenu Impulse Mode Automatic Scan Mode ZigZag Start Scanning Back To Main Menu Illustration 7 4 Ground Scan Parameter You can modify the following parameters the underlined values correspond to the setting made by the factory e Impulse Mode Automatic Manual If you are working in the Manual mode the measured values will only be recorded when using the joystick or by pushing on the start button If you select the Automatic mode the measured values will be recorded represented on the display continuously e Impulses Auto 10 20 50 Number of measured values per search line If you select Auto the number of impulses can be adap
66. the same direction Even in the Zig Zag scan mode the orientation of the probe must not be changed That means you are not allowed to turn yourself with the device and the probe at the end of the scanning path Instead you Should walk backwards and continue scanning Otherwise your obtained graphic includes red or blue stripes These stripes throughout a scan are commonly referred to as Rotational Errors 8 2 2 Parallel or Zig Zag For skilled users of the eXp 4000 both scan modes are suitable According to experience the best graphics has been received in the Parallel mode because you are starting at the same point and traveling in the same direction It is also easier to control your walking speed OKM Ortungstechnik GmbH www okmmetaldetectors com Field procedure 63 Especially in uneven territories like mountain sides acclivities or other inclined layers the parallel mode is preferred When it comes to speed the experienced user will very often use the Zig Zag mode for the initial scan to determine if there are anomalies in the area worth further research 8 2 3 Manual or automatic impulse mode Large even or passable surfaces are commonly measured in the automatic mode The manual impulse mode is mostly used for difficult uneven terrain areas where there is quite a bit of growth and if the measurement result needs to be very accurate In terrains with difficult access like mountain cliffs and sides slippery surf
67. tration 10 3 Internal Hardware Error OKM Ortungstechnik GmbH www okmmetaldetectors com Error Messages 73 Message 10 4 appears if the battery is low because of a long operating time with the device and not enough voltage is available You should power off the device and charge the external power supply as soon as possible If you continue operating with the device it could be possible that data gets lost Illustration 10 4 The external power supply has to be charged Because there is a PC module integrated in the device you have to shutdown it like a normal computer Therefore you have to use option Exit from the main menu The message like in figure 10 5 remind you to wait until the device powered off by itself Illustration 10 5 Shutting down the system If the device itself is not able to power off a message like in figure 10 6 is shown In this case you simply power off your external power supply Illustration 10 6 Shutting down the system is not possible OKM Ortungstechnik GmbH www okmmetaldetectors com
68. ubsection Installed devices can be removed using the Device Manager by simply right clicking on the mouse and selecting Uninstall This will delete the associated registry entries for that device only Device Manager LE E File Action View Help a g user PC b JE Computer b cq Disk drives pE Display adapters gt DVD CD ROM drives b 4g IDE ATA ATAPI controllers b Keyboards gt A Mice and other pointing devices b E Monitors b EF Network adapters gt FF Ports COM amp LPT b pp Processors b Q Sound video and game controllers b LE Storage controllers p gi devices ae F Universal Serial Bus controllers E OKM Quick Lint S F Standard Enh Update Driver Software vee F Standard Ope Disable 9 USB Root Hu Uninstall ia ig USB Root Hu Scan for hardware changes Properties Uninstalls the driver for the selected device Illustration 2 36 Uninstall USB drivers on Windows 7 Step 1 Windows 7 provides an automatic method to delete driver files via check box Delete the driver software for this device on the uninstall dialog box Just mark the check box and click OK to remove the installed USB drivers of your device Confirm Device Uninstall ES OKM Quick Link Waming You are about to uninstall this device from your system Delete the driver software for this device Illustration 2 37 Uninstall USB drivers on Windows 7 Step 2
69. w installed driver software compatible with the device and all driver software in the same category as the device Illustration 2 21 Update USB drivers on Windows Vista Step 5 After entering the drivers location select Next to start the installation amp mi Found New Hardware OKM Quick Link The software for this device has been successfully installed Windows has finished installing the driver software for this device OKM Quick Link Illustration 2 22 Update USB drivers on Windows Vista Step 6 When the installation has finished the completion screen from figure 2 17 is displayed Press Close to close this window and go back to the Device Manager OKM Ortungstechnik GmbH www okmmetaldetectors com Install Uninstall USB drivers on Windows 25 The Device Manager will now show a device under Universal Serial Bus Controllers indicated in the screenshot below as OKM Quick Link gay Device Manager File Action View Help e9 mHE BAR eee fq Imaging devices ee Keyboards a Mice and other pointing devices aA Modems ce Monitors aP Network adapters ce Portable Devices ca Ports COM amp LPT a Processors H Sound video and game controllers a Storage controllers m g System devices ta 7 Universal Serial Bus controllers S F OKM Quick Link Realtek USB 2 0 Card Reader Standard Enhanced PCI to USB Host Controller Standard Enhanced PCI to USB Host Controller Standard OpenHCD USB Host Co
Download Pdf Manuals
Related Search
Related Contents
35495.2 BLH 550 X Pro Kit istruzioni LONE STAR ITA.cdr Manual de uso y mantenimiento de los grupos Hand-manipulated electronic camera tethered to a personal computer Samsung GT-E2152L User Manual Document PDF M2 GB User manual Copyright © All rights reserved.
Failed to retrieve file