Contents
1. dipswitches should be moved inwards The dipswitches are placed under the lower door to open it put a screwdriver under the edge and pry it open CAREL S p A CAREL Tel 39 0499716611 Fax 39 0499716600 Via dell Industria 11 35020 Brugine Padova Italy http www carel com e mail carel carel com CAREL si riserva la possibilit di apportare modifiche o cambiamenti ai propri prodotti senza alcun preavviso CAREL reserves the right to modify the features of its products without prior notice cod 050003210 rel 1 2 13 01 2004
2. PTI of the insulation materials gt 250 V e Period of electric stress across the insulating parts Long e Category of resistance to heat and fire D e Category immunity against voltage surges 2 Collegamenti Connections dist max vedi caratteristiche sonde for max distance refer to probe specifications L sonde umidit humidity probes mado m interfaccia interface T 20m conio dC controller d pCOUMI2000 pCo pCo i ili pco 1 1 cilindro lt cylinder Fig 2 Schema di collegamento Connection diagram humidifier inputTAM input Cond r r2r1 c2 ci J o eo enopram conecevel elle foz Tor J Lelli ni n ici tocuoi dip switch Dig output Level input Level e Ju uu analoa output PI i PCO Fig 3 Esempio di schema elettrico Example wiring diagram sonda umidit humidity probe Level humidity input conduc input Cond TAM Level input M NS DOSI DON DO DO ant opa a 1901 a TAM input i gli ingressi e le uscite utilizzati dipendono dal software applicativo the inputs and outputs used depend on the application software Fig 4 COLLEGAMENTI In generale il collegamento tra un umidifi
3. catore e un pCO pu essere schematizzato come in Fig 2 Effettuare il collegamento rispettando le distanze massime riportate e posizionando i cavi su canaline dedicate separati dai cavi di potenza e fonti di disturbo ALIMENTAZIONE Rispettare le polarit G e GO del PCOUMI2000 e del controllo pCO quando l alimentazione fornita da uno stesso trasformatore sensori di rilevamento livello acqua o conducibilit dell umidificatore non hanno polarit quindi non necessitano di particolari attenzioni durante il collegamento alla scheda Schema di collegamento CONNECTIONS The connection diagram between the humidifier and the pCO is shown in Fig 2 Make the connection respecting the maximum distances recommended and positioning the cables on dedicated channels separately from the power cables and disturbance sources POWER SUPPLY The polarity of G and GO on the PCOUMI2000 and on the pCO controller must be observed when the power is supplied by the same transformer The sensors measuring water level or conductivity in the humidifier have no polarity and therefore no special attention is required when connecting these to the board Connection diagram Morsetti Tipo Natura G G 24 Vac GO GO riferimento alimentazione TI input TAM TAM induttivo 0 2 Vac T2 GND GND riferimento segnali CI input conducibilit acqua misura resistiva eseguita C2 con 0 7 Vac 5 kHz Li input alto livello ac
4. cod 050003210 rel 1 2 13 01 2004 PCOUMI2000 Scheda per gestione umidificatore OEM per pCO OEM humidifier control board for pCO CAREL LEGGI E CONSERVA gt QUESTE ISTRUZIONI lt WU ini A u Ne UNIR humidifier interfoce sj idii I Dimensioni 4 moduli DIN Dimensions 4 DIN modules e FE 3 58 eee 70 READ AND SAVE THESE INSTRUCTIONS 60 Fig 1 D Vi ringraziamo per la scelta fatta sicuri che sarete soddisfatti del vostro acquisto CARATTERISTICHE GENERALI Il modulo PCOUMI2000 un interfaccia dei controllori elettronici pCO Permette di controllare i parametri fondamentali degli umidificatori OEM prodotti da CAREL alto livello e conducibilit acqua di alimento nel cilindro sensore TAM di assorbimento corrente direttamente dal regolatore elettronico a microprocessore pCo pCO pC0 pC0 I valori raccolti dagli appositi sensori vengono convertiti in segnali compatibili dagli ingressi presenti nel pCO per maggiori informazioni si rimanda al relativo manuale utente del programma applicativo L interfaccia PCOUMI2000 rispetto all interfaccia PCOUMID000 si differenzia per maggior precisione e immunit ai disturbi sia per la misura di conducibilit che per la misura del sensore di livello il segnale di alto livello acqua pu esse
5. iers manufactured by CAREL high water level water conductivity in the cylinder and TAM current sensor directly from the pCO pCO pC0 pCO electronic microprocessor controller The values read by the special sensors are converted into signals that are compatible with the inputs on the pCO for further information refer to the corresponding application software user manual The PCOUMI2000 interface differs from the PCOUMID000 interface in the following ways greater precision and immunity to disturbances for both the conductivity and the level sensor the high water level signal can be managed either by a digital or analogue output Consequently both the PCOUMID000 and the PCOUMI2000 boards can be connected to the pCO with the only requirement being that a special parameter has to be set to allow the software to use the correct conductivity curve TECHNICAL SPECIFICATIONS power supply 24 Vac 15 power consumption 3 W 5 VA terminal blocks wire cross section min 0 5 mm max 2 5 mm operating conditions 10T60 C 90 rH non condensing storage conditions 20T70 C 90 rH non condensing pollution normal dimensions mm 110 8 x 70 4 x 60 case index of protection IP20 classification according to protection against electric shock Class Il All outputs are protected against short circuits INSTALLATION The device is installed by mounting on a standard DIN rail DECLARATIONS e
6. qua misura resistiva eseguita con L2 0 7 Vac 5 kHz 01 output alto livello acqua switch ON OFF optoisolato 02 digitale digitale Level output alto livello acqua analogico 0 1 Vdc 0 2000 uS cm Terminals Type Description G G 24 Vac G0 GO power supply ground TI TAM input 0 to 2 Vac inductive T2 GND GND ground CI water conductivity input resistive measurement made C2 at 0 to 7 Vac 5 kHz L1 high water level input resistive measurement made L2 at 0 to 7 Vac 5 kHz 01 high water level digital ON OFF switch 02 digital output optically isolated Level analogue high water level output 0 to 1 Vdc 0 2000 uS cm Cond output conducibilit acqua 0 1 Vdc 0 2000 uS cm TAM output TAM 0 1 Vdc 0 400 corrente nominale non usato n c Dipswitch Di default il PCOUMI2000 settato per lavorare con i pCO pCO e pCO e i quattro dip switch sono posizionati verso l esterno Per il funzionamento con il pCO i dipswitch vanno spostati tutti quattro verso l in terno dipswitch si trovano sotto lo sportellino inferiore rimuoverlo con l utilizzo di un cacciavite Cond water conductivity output 0 to 1 Vdc 0 2000 uS cm TAM TAM output 0 to 1 Vdc 0 400 rated current not used n c Dipswitch As default the PCOUMI2000 is set to work with the pCO pCO and pCO and the four dipswitches are positioned towards the outside For operation with the pCO all four
7. re gestito sia con uscita digitale che analogica Risulter dunque possibile collegare al controllore sia la scheda PCOUMID000 che la scheda PCOUMI2000 con l unica accortezza di dover configurare un opportuno parametro in modo da permettere al software di utilizzare la corretta curva di conducibilit CARATTERISTICHE TECNICHE tensione d ingresso 24 Vac 15 potenza assorbita 3W_ 5VA morsettiere sez conduttori condizioni di funzionamento 10T60 C 90 U R non condensante condizioni di immagazzinamento 20T70 C 90 U R non condensante grado di inquinamento normale dimensioni mm 110 8 x 70 4 x 60 grado di protez fornito dall involucro __1P20 classificazione secondo la protezione contro le scosse elettriche min 0 5 mm max 2 5 mm Classe Il Tutte le uscite sono protette da cortocircuito INSTALLAZIONE Il montaggio previsto mediante fissaggio su guida omega guida DIN standard DICHIARAZIONI e PTI dei materiali usati per l isolamento gt 250 V e Periodo di sollecitazioni elettriche delle parti isolanti Lungo e Categoria di resistenza al calore e al fuoco D e Categoria immunit contro le sovratensioni 2 GB Thank you for your choice We trust you will be satisfied with your purchase GENERAL CHARACTERISTICS The PCOUMI2000 module is an interface for the pCO series electronic controllers It is used to control the fundamental operating parameters of the OEM humidif