1. admin only To set the working mode of the of digital input 2 use the command DIG 2 working mode timing alarm unit where gt OPEN CLOSE for the alarm with regard to the open or closed status of the input timing alarm gt alarm delay time around 18 hours unit gt h hours m minutes s seconds working mode Example DIG 2 CLOSE 20 M gt alarm if the status of input 2 remains closed for 20 minutes Setting alarm text for admin only To set the text which will be sent to the staff numbers use command DIGTXT 2 alarm text alarm return text where gt string of max 60 characters of text that are sent to staff in case of alarm gt separator for alarm return text alarm return text gt string of max 60 characters of text that are sent to staff in case of alarm return alarm text Example DIGTXT 2 burglar alarm burglar alarm end Setting display To know the configuration of the DIG2 input use the command DIGINFO Here is an example of a possible reply DIG 2 OPEN ALARM CLOSE 10S which means Digital input 2 open alarm defined when input 2 remains closed for 10 consecutive seconds ADVANCED INSTRUMENT MANAGEMENT Modify admin number for admin only The admin number can be modified by sending the following command from the current admin number ADMIN new admin number The new admin number will receive a confirmation text message Note If the admin number is lost it can be cha
2. than 48kW the POK alarm is generated When the power drops below 44 5kW 48 3 5 generates the alarm RPOK SETPOK NO gt remove the production threshold currently setting Note The behaviour of the instrument in case of alarm conditions POK RPOK is determined by commands OUTALARM activation outputs or SENDALARM for sending sms or ring Automatic activation of an output on alarm conditions for admin only It is possible to make the outputs switch automatically when there is one of following alarm Table 4 Type of alarm Alarm description DIG2 Alarm from digital input 2 LOWBAT Low battery alarm POWERF No network alarm POK Production exceeds the threshold defined with SETPOK The output OUT2 is preset to switch for 30 seconds when there is an alarm at digital input DIG2 The OUTALARM command enables the output behaviour to be modified OUTALARM output number output status cause of alarm reset alarm mode gt lor2 gt ON OFF or DISABLE gt please see table 4 gt MAN manual AUTO at the end of an alarm condition or timing maximum around 18 hours with unit of measurement s seconds m minutes h hours output number output status cause of alarm reset alarm mode Examples OUTALARM 2 OFF DIG2 MAN gt in the case of digital alarm 2 output 2 becomes OFF and remains in such status OUTALARM 1 OFF POWERF AUTO gt The output 1 goes OFF in case of no network and remains in this status until
3. F reply to enabled text message reply to enabled ring tone and change output status by pressing the relative key Modify output name for admin only To assign a name to the output that recalls the device to which it is connected use the command OUTTXT output number output label Some examples OUTTXT 1 siren OUTTXT 2 valve OUTTXT 2 NO assigns the name siren to output 1 assigns the name valve to output 2 restores the original name to output 2 A string of a maximum of 10 characters with no spaces can be assigned as a name If an alternative number for an output is defined it is possible to use this name to indicate the output in the transmitted commands For example valve ON 10 M activates output 2 valve for 10 minutes INPUTS MANAGEMENT GWI solar has two digital inputs whose status is signalled by two green leds on gt input is short circuited off gt input open and an analog input The digital input DIG and the analog input are pre set to be connected to the to the pulse output of the energy meter and the radiation sensor respectively Their behaviour cannot be modified The digital input DIG2 can on the other hand be used with the discretion of the user for example for connecting a burglar alarm system In particular digital input 2 can be connected to signals from switches ON OFF Note The minimum measurable pulse length is 20ms max frequency 25Hz Set working mode for digital input 2 for
4. INSTALLATION commands executed will only be those whose reply is contained in a standard text message 160 characters To enter numbers with the decimal separator you need to use a full stop V31S00546 020 042011 sjem Vemer S p A 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it User manual GSM COMMUNICATION INTERFACE uN Read all instructions carefully Preparation Mod Tle solar CE SPA The structure of a reply to a command is similar to the command itself with the addition of the symbol to indicate the current status For example Disable the pin code request from the sim card which will be inserted into the GWI solar i lt lt Insert the sim card into the slot type push push The direction of insertion provides that the bevel of the sim card goes inside in the left m Tlc solar is a system for the remote control of photovoltaic systems by sending text messages or ring tones to certified users The heart of the system is made up of GWI solar which compares the signal coming from the produced energy meter on the system and that coming from the radiation sensor to check if production complies with the radiation conditions thus enabling any malfunctions to be found in time Any fall in production is automatically communicated by the system by sending text messages to the selected users Furt
5. S new password with new password which should have a maximum of 8 figures For example PASS 11223344 e Assigning system name for admin only It is possible to assign a name to the plant where the Tlc solar is installed In this way each alarm text message or reply from the GWI solar will be headed by its given name The command is NAME name system A name with a maximum string of 20 characters can be assigned To cancel write NAME disabled e Count sms sent for admin only You can check the number of text messages sent by the tool with the command NSMS The instrument responds to the sender with a text message containing the number of SMS sent in count includes both sms sms alert that the response to commands NSMS RESET lets you reset the counter e Key operating mode setting for admin only By briefly pressing a key the relevant output can be adjusted Output behaviour can be defined with the following command OUTKEY functionality with functionality that can assume the values TOGGLE gt when the key is pressed the output switches ON OFF in a bistable manner BLOCK gt disables the key functions it will no longer be possible to access the programming mode If the value is omitted the current instrument status will be the reply SWITCHING ON SWITCHING OFF AND RESET THE GWI SOLAR e Turn off the instrument gt Hold approximately 10 seconds for either the 1 SET or 2 until all LEDs
6. an alarm return OUTALARM 2 OFF DIG2 25 M gt output 2 goes OFF for 25 minutes in case of alarm on digital 2 OUTALARM 2 DISABLE gt function disabled Setting the output status The output status can be piloted simply with the command OUT output number output status status holding time unit of measurement where output number gt indicates the output to which reference is made 1 or 2 output status gt can assume the values ON OFF permanence status time gt maximum settable time 130 years optional parameter unit of measurement gt s seconds m minutes h hours optional parameter Some examples OUT 1 OFF 10S gt sets the relay 1 OFF for 10 seconds OUT 20N12S gt sets the relay 2 ON for 12 hours Send text message to sender setting for admin only The instrument can be set to send the sender a text message of confirmation upon receiving a command via a text message The command is OUTRISP status with status that can assume the values ON gt enables the sending of a text message of reply to the sender OFF gt disables the sending of a text message of reply to the sender If the status is omitted the reply will be the current instrument status Setting display The device can be queried to know the relevant configuration using the command OUTINFO Here is an example of a possible reply OUT 1 ON OUT 2 OFF OUTRISP ON RINGRISP ON OUTKEY TOGGLE meaning output 1 ON output 2 OF
7. de the text Setting text message time for admin only It is possible to synchronise the date and time of the instrument with the command RTCSMS To synchronise the instrument reads the date and time in the received text message If there is a prolonged black out with the battery going flat it is necessary to repeat the command If this command is not carried out the instrument substitutes date and time with It is also possible to link this command to the end of any command text message For example OUTALARM 2 OFF POWERF AUTO RTCSMS Disable alarm messages For admin only Command MSG manages enablement or not of forwarding messages to the staff If MSG is OFF the forwarding of all the messages or signalling of alarms managed by SENDALARM is disabled MSG ON Enables the transmission of messages and ringtones MSG OFF Disables the transmission of messages and ringtones OTHER FUNCTIONS Set threshold production By the command SETPOK you can set a threshold of production which if exceeded generates an alarm condition alarm POK In this way you can for example to switch a relay output when the power exceeds the threshold defined The syntax is SETPOK threshold differential threshold gt differential gt where represents the threshold in kW for alarm POK represents the hysteresis in kW for the return alarm RPOK For example SETPOK 48 3 5 gt if the power produced is greater
8. hase network In this phase it is possible to add other telephone numbers as well as the administrator s IMP Inverter malfunction max 690 kW max 69 kW max 15 kW Sia oe where alarm signals will be sent by choosing for each number which type of RIMP Alavi eain ierte malneton ENERGY 400D PWRi ENERGY 400 D90 ADR 230 D63 GWI SOLAR TMC 10 12 Furthermore it i possible tomodity the automatic forwarding plan for messages with DELTA Alarm energy production lower than predicted planned set times or activate automatic switching function for an output following a specific RDELTA Alarm return energy production alarm condition POK Production exceeds the threshold defined with SETPOK OUT 2 RPOK Alarm return energy production above the threshold i n STRUCTURE OF A COMMAND TEXT MESSAGE o n ee Fara a hh oo fF l It is possible to define which types of alarms are sent to each staff number and in which TA D i DRIE The general structure of a text message is as follows format text message or ring tone The first 5 staff numbers are set as follows a password separator command separator parameter1 separator parameterNo Table 2 T TE here TEE S g S S ls a Number Communications received Mode a T ae ical fi i i STAFF 1 Each alarm event Text message 10 11 E 13 14 15 16 17 18 fo 17 10 17 12 13 14 i a a password gt numerical field of a maximum of 8 figures 9 1 ra 15 16 7 18 sile mm to Neel ella separat
9. hermore GWI solar has another input available for connecting a burglar alarm and two outputs which can be activated manually or following an alarm OUTKEY BLOCK gt OUTKEY BLOCK MODIFY PULSE WEIGHTS for admin only Note the rechargeable sim needs a periodical Pe By default the pulse weight that the GWI solar receives from the energy meter minimum top up usually once a year in order to eat is 0 1 kWh If it is necessary to modify this value use the command be valid Check with your operator about the renewal mode GWI solar TECHNICAL CHARACTERISTICS WIMP pulse weight where Power supply 12V AC from TMC 10 12 as shown in the diagram Absorption 100mA max Note The sim card insertion and removal operations should be carried out with Output SAFETY WARNINGS the instrument switched off and not powered up please see the relative chapter pulse weight gt new value to be given to a pulse two bistable relays with change over contact During the installation and operation of the device observe the following instructions for switching off the instrument E wae E EEEE T E T EOT A io Fl einer A ar dh Dehli a e Wiri To read the current value use the command WIMP with no parameters Signalling LEDs 2 The instrument must be installed and activated in compliance with current electric iring i Two red leds for output relay status signalling systems standards Two green leds for digital input stat
10. if there is an alarm on Digital 2 Note a new setting SENDALARM for a given type of alarm will overwrite the present one for which it is necessary to indicate all the receivers of the alarms in one single command NB to cancel a SENDALARM setting enter 0 as the recipient Example SENDALARM DIG2 0 gt cancels the send alarm settings Set the alarm ringing time for admin only If you have chosen to send alarms ringing through phone see control sendalarm you can set the length of the ring with the command MAXRING number where number gt duration of the ringing in seconds values between 0 and 255 By default the duration of the ringing is 15 seconds Planned message sending function for admin only The instrument is set by default to send to the admin number on a monthly basis and to the staff member 2 if defined a text message with the value of produced energy The SCHEDTIME and SCHEDTXT commands enable the period and the text of the message to be modified respectively SCHEDTIME period offset start where gt interval expressed in hours between one forwarding and another gt start delay expressed in minutes period offset start For example SCHEDTIME 2415 gt send text message every 24 hours the first in 15 minutes SCHEDTIME 260 60 gt send text message every 15 days the first in one hour SCHEDTIME 0 SCHEDTXT text gt disable sending where text gt text message that will be sen
11. inistrator with the value of produced energy send a text message containing the value of produced energy and instantaneous power following a ring tone forward messages destined to the GWI solar and not recognisable as commands for example a text message from a telephone service provider to the administrator To have a complete overview of the telephone book write STAFF without parameters Note the admin number is inserted by default as staff number position 1 ALARMS MANAGEMENT The possible alarm sources are reported in the following table J a Table 1 5 3 N 2 Furthermore a text message is sent to the administrator in cases of Type of alarm Alarm description De ee TTT TTT desea ate ee alarm DIG2 Alarm from digital input 2 i 3 no meter pulses alarm Ore GWI SOLAR cikat Generator Eeneral panel o aa ie heldalden RDIG2 Alarm return from digital input 2 GWI SOLAR TT panel TT no electrical network or buffer battery flat alarm LOWBAT Low battery alarm ns For each of the alarms listed above an alarm return text message is sent POWERF No network alarm pn RPOWERF Alarm return for no mains By default the pulse weight received from input DIG is 0 1 kWh modifiable SCHED Message for periodici warding e Advanced configuration LUX Radiation sensor malfunction 2 RLUX Alarm return radiation sensor Three phase network Three phase network Single p
12. nds this will end when it starts blinking green once a second signalling the correct reception of the gsm network If this should not be the The staff numbers are identified progressively from 1 to 10 The first 5 staff numbers are already associated by default to 5 well defined alarm Q The device status is signalled by the led situations please see Alarms management even if they can be modified SWITCHED OFS no ipowersupply todevice Code Model Description case please see the overview Device state RED BLINKING gt sim card not inserted or pin active KT018000 _ Tic solar 230 Kit telecontrol for single phase systems up tol kW Kit telecontrol for single phase systems up to 15 kW e Basic configuration To add a staff number RED STEADY gt insufficient gsm field KT018500 Tlc solar 400 Kit telecontrol for three phase systems up to 69 kW l GREEN STEADY gt initialising instrument network search KT021500 Tlc solar 400TA Kit telecontrol for three phase systems up to 690 kW Consists in defining the admin number which has full control of the system usually for the send the following command from the admin number GREEN BLINKING gt gsm network connection owner to whom alarm messages are sent GREEN BLINKING VELOCE gt command ring tone or text message incoming GREEN RED BLINKING gt active programming mode YELLOW BLINKING gt gsm network connection but battery flat QUICKLY BLINKING RED gt modem error or fail
13. nged only by forcing a reset thus losing all the previously enabled numbers To avoid having to re enter them manually please refer to section Sim card management Sim card management for admin only The staff telephone numbers are saved in the memory of the device In case of reset this implies the loss of all the enabled utilities To avoid having to re enter all the numbers manually it is possible to make a backup copy of the sim card through the following commands to be given by the administrator only STORE RESTORE creates a copy in the sim card of all the saved staff numbers only restores the numbers previously saved with STORE Therefore once all the telephone utilities have been enabled it is advisable to make a backup of the phone book Forwarding management function for admin only The instrument can be set to redirect to a specified number all the text messages it receives and does not recognise as commands The command is FORWARD number By default the number to which these text messages will be forwarded is the admin number FORWARD OFF disables the function The text messages which are forwarded to the specified number begin with the string FW e Password management for admin only A text message sent from the admin number enables an instrument protection password to be changed to be used in case you wish to send a command via text message from a disabled number The command is PAS
14. off During the pression of the key the output led P blinks quickly and the led blinks green or yellow for the first 5 seconds and green red for the other 5 seconds e Turn on the instrument without reset gt Press 2 The LED will be green initially fixed and then begin to flashing green or yellow indicating the correct reception of the GSM signal e Turn on the instrument with reset gt Press the 1 SET All LEDs will illuminate for a few seconds indicating that the reset occurred after which the LED begins to flash green or yellow indicating the correct reception of the GSM signal Note The reset erases all data settings and users stored tool and restore factory defaults see box on Password 12345678 Relay output status Off ADMIN number Undefined STAFF numbers Not defined STAFF behaviour 1 5 Predefined please see table 2 Caller control Active Automatic call answer Enabled Reply to text message commands Active Forwarding unknown text messages Active to Admin No power supply warning Active REFERENCE STANDARDS Compliance with Community Directives 2006 95 EC low voltage 2004 108 EC Electromagnetic compatibility 1995 5 EC R amp TTE is declared with reference to Harmonised Standards e EN 61010 1 e EN 61000 6 2 EN 61000 6 4 e EN 60950 1 e EN 301489 1 EN 301489 7
15. or gt comprised of one or more space characters STAFF 2 Scheduled event only SCHED Text message H a pa seer 2 ae ae es S a f STAFF 3 Alarms only LUX RLUX IMP RIMP DELTA RDELTA Text message i LB f 12v parameter NE E ey mrt terrae STAFF 4 Burglar alarm only DIG2 RDIG2 Text message dainas jidai aia The password field may be omitted if the command is given by a registered STAFF 5 No electrical network only POWERF RPOWERF LOWBAT Text message ad _ O number Several commands may be included in one text message In this case the To define the behaviour of other staff numbers or modify the behaviour of the pre set ones use the command SENDALARM type of alarm recipient type of signalling recipient type of signalling type of alarm gt please see table 1 receiver gt index of a staff number signal type gt SMS to receive a message RING a ringtone Some examples SENDALARM DIG2 1 SMS 2 RING 3 RING gt when there is an alarm on digital input 2 it sends a text message to contact staff member 1 and a ring tone to staff members 2 and 3 SENDALARM RPOWEREF 2 SMS 6 RING gt when there is an alarm return due to no power supply an alarm text message is sent to staff member 2 and a ring tone to staff member 6 SENDALARM with alarm type displays the alarm warning parameters for the type of selected alarm Example by sending the command SENDALARM DIG2 the device responds with STAFF 2
16. r 4 DIN modules 8 Carefully respect the wiring diagrams fo install the instrument connect any burglar system presence sensors microswitches at digital input 2 It is possible to create a telephone book containing up to 10 telephone numbers staff Backup battery capacity approximately 1 hour 9 Before accessing the connection terminals verify that the leads are not live GWI solar DIG2 terminals 11 and 13 numbers which can receive text message or ring tone in case of alarms receive text message with the produced energy and the instantaneous power following a ring tone receive text message following a scheduled event 10 Do not power or connect the instrument if any part of it is damaged 11 The use of a GSM device can cause interference with the functioning of electronic devices non screened from radiofrequency signals electromedical devices pacemakers hearing aids etc 12 In case of fault do not service the device yourself but contact the after sales service 13 The instrument is aimed for use in place with over voltage category III and pollution degree 2 as per standards EN 60730 1 connect the transformer to the GWI solar and the network voltage For a detailed description of the connections please see the diagram Connection diagram GWI solar DEVICE STATUS Once the kit has been powered up the led of the GWI solar relating to the device status will remain on steady green for around 30 seco
17. sitions 2 4 and 7 hours of sunshine STAFF 2 044177458 4 392123445 7 12345678 At the end the admin number will receive a text message and from then on it will begin to monitor the produced energy To cancel a staff number use the word NULL For example if you want to cancel the staff number 4 leaving the position in the telephone book empty Inverter STAFF 4 null e Default settings sensor F Burglar alarm Produced energy unidirectional meter Bidirectional produced absorbed energy meter The factory settings for the kit provide for the admin number to receive a series of text messages send a monthly text message to the adm
18. t The text can contain a few special characters symbols which indicate the meter or pulse meter values These characters are solved by the instrument when the message is sent For example SCHEDTXT Produced energy P1 kWh The text that will be sent could be Energy produced 32 kWh with the value of meter P1 at 32 The possible symbols are the following Table 3 Tag Description PT1 pulse meter total not zeroable associated with digital input 1 P1 pulse meter associated to digital input 1 P1R pulse meter associated to digital input 1 with auto reset after forwarding D2 digital input 2 status In the message are the words OPEN LO or CLOSE HI 01 Output status 1 In the message are the words ON or OFF 02 Output status 2 In the message are the words ON or OFF CKS date and time of the forwarding of the last scheduled event CK current date and time If tag P1 or P2 are followed by a numeric value this is used as a multiplicative factor for the meter display Example SCHEDTXT Energy produced today P1 1 34 kWh The value of the pulse meter is shown as multiplied by 1 34 and on the forwarded message in place of P1 1 34 will be a number obtained by multiplying 1 34 by the value of the pulse meter associated with digital input NB The number of decimal numbers is the same as the multiplier in the case of previous example 2 NB Each tag must be separated by at least 1 space insi
19. ure if still flashing The Tlc solar is made up of GWI solar control unit code VE326500 radiation sensor code VE327300 TMC 10 12 transformer code VN314100 ADR D 230 D63 energy meter code VE035200 single phase systems or STAFF index telephone number where MEMORISING ADMINISTRATIVE NUMBERS gt position in the staff telephone book where the new number is saved gt number to be added to the telephone book index press the 1 key of the GWI solar for 5 seconds until the led starts blinking red green telephone number Note blinking 1 lamp second quickly blinking 5 lamps second ENERGY 400 D90 code VN984100 three phase 69kW systems or ENERGY 400D PWRi code VE120200 three phase 690kW systems alternately carry out a ring tone with the number which you want to set as admin number The caller will receive a confirmation text message that this has taken place Note after having set the admin number the GWI solar will carry out a self For example to insert the staff number 392123445 in position 4 STAFF 4 392123445 It is also possible to enter several staff numbers using one command only CONNECTION DIAGRAM calibration procedure during which time it analyses all the parameters of the For example if you want to insert the numbers 044177458 392123445 and 12345678 in system where it is installed To carry out this operation the GWI solar needs a few po
20. us signalling 3 After installation inaccessibility to the connection terminals without appropriate tools Multicolour leds for device status signalling must be granted GSM Quad Band module 900 950 1800 1900 MHz 4 Do not use the instrument for purposes other than indicated SMA F connector for external antenna provided with 3 m long cable 5 The device must be installed in a electric closed panel well protected Working conditions 0 50 C 10 90 non condensing 6 A two pole disconnect device shall be provided as part of the building installation For example WIMP 1 gives the value 1 00 kWh to each pulse WIMP 0 1 gives the value 0 10 kWh to each pulse WIMP restores the current weight of the pulse Attach the radiation sensor near the photovoltaic panels with the same inclination and connect it to the analog input of the GWI solar the white black wire to terminal 14 the black one to terminal 12 Caution the sensor must be positioned so that the solar rays do not hit it before they hit the panels in order to avoid false alarms being sent for example at dawn Degree of protection IP40 7 A protection device against over currents should be installed in the electrical system connect the energy meter down from the solar production inverter and connect the pulse MEMORISING STAFF NUMBERS for admin only Insulation class II upstream of the device output meter at input 1 of the GWI solar DIG1 terminals 10 and 13 l l _ Containe