Contents
1. Program Refer to the programming steps as outlined in the Residential 5 2 or 7 Day programming section The only difference is that two schedules per day Day and Night will be programmed Commercial Default Schedule eee 1 Time eating Temperature Schedule 7 7 DaysPerWeek Per Week Heating Cooling 6 00 AM i 10 00 PM MANUAL MODE When the T 21 P is configured for manual mode it provides setpoint adjustment Mode and Fan selection only The thermostat clock is hidden and no programming is necessary Typical Manual Mode Display Fan Automatic TROUBLESHOOTING Display is blank Check HVAC circuit breaker and reset if necessary Make sure power switch at HVAC system is on If thermostat is battery powered only replace batteries Heating or cooling Touch MODE to set system to Heat or Cool Set the heating does not respond temperature a few degrees above the space temperature or the cooling temperature a few degrees below the space temperature Heat or Cool should flash confirming that the thermostat is calling The thermostat has a 4 minute equipment time delay for cooling and heat pump systems Wait 4 minutes for the system to restart Contact your installing HVAC contractor if T 21 P does not function properly J k O 5418 Elmwood Avenue Indianapolis IN 46203 6025 acKS Cn Toll Free 888 652 9663 Fax 317 227 1034 SYSTEMS www jacksonsystems com 14 06 1074 080811
2. flash Use the UP and DOWN arrows to adjust the hour If the time is PM adjust the hour until the PM symbol appears Touch the clock again The minutes will flash Use the UP and DOWN arrows to adjust the minutes Touch the clock again and the thermostat will resume normal operation Mode selection The T 21 P can control both heating and cooling Touch the Mode box to cycle through and select available modes Based on equipment and thermostat configuration mode selection can be as follows Mode Heat Fan selection Off Thermostat will not call for heating or cooling Heat Thermostat only controls heating When heating system is running Heat flashes Cool Thermostat only controls cooling When cooling system is running Cool flashes Auto Thermostat controls both heating and cooling Heat or Cool will flash when equipment is running E Heat Emergency heat for heat pump systems should the compressor fail Touch the Fan box to select Automatic or Always On fan mode In Automatic mode the fan operates with a heating or cooling call If set to Always On the fan will run continuously If the thermostat is turned Off while the fan is set to Always On the fan will switch to Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off Fan Autg yatic Programming 4 daily events 5 2 schedule Touch and hold the Program box until the UP and DOWN arrows along with the flash
3. JacksOn SYSTEMS Comfort System T 21 P Touchscreen Thermostat User Manual Version 1 40 INTRODUCTION Your new Comfort System T 21 P touch screen thermostat has been manufactured using the highest quality components and design currently available As a result when properly installed and configured by a professional heating and air conditioning contractor the T 21 P will provide years of trouble free operation The T 21 P has been designed to be an attractive highly reliable and easy to use thermostat By taking time to read and understand this User Manual you can take advantage of the many features offered in this premium product Great care has been taken in the preparation of this manual Jackson Systems takes no responsibility for errors or omissions contained in this document It is the responsibility of the user to ensure that this thermostat or equipment connected to it is operating to their respective specifications and in a safe manner Due to ongoing product improvements Jackson Systems reserves the right to change the specification of the T 21 P thermostat or its components without notice All right reserved Jackson Systems LLC 2011 Intellectual rights apply BASIC FUNCTIONS To simplify use the T 21 P only displays information relevant to the current mode of operation When adjustments are required the thermostat will display additional functions Set temperature displayed or hidd
4. Mode box to cycle through and select available modes Based on equipment and thermostat configuration mode selection can be as follows Heat Off Thermostat will not call for heating or cooling Heat Thermostat only controls heating When heating system is running Heat flashes Cool Thermostat only controls cooling When cooling system is running Cool flashes Auto Thermostat controls both heating and cooling Heat or Cool will flash when equipment is running E Heat Emergency heat for heat pump systems should the compressor fail Fan selection Touch the Fan box to select Automatic or Always On fan mode In Automatic mode the fan operates with a heating or cooling call If set to Always On the fan will run continuously If the thermostat is turned Off while the fan is set to Always On the fan will switch to Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off Fan Autg atic Programming 2 daily events 7 Day or 5 2 Schedule Touch and hold the Program box until the UP and DOWN arrows along with the flashing days of the week appear The program format starts with Monday for 7 Day programming and Monday through Friday for 5 2 programming You will now be able to program two schedules per day Day and Night with individual heating and cooling setpoints for each schedule If the Programmable Fan option is ON you may also program the fan operation for each scheduled event
5. atile memory Residential 5 2 Day FactoryDefault Schedule Start Time Set Temperature Schedule Mon Fri Sat Sat Sun i Morning 6 00 AM 70 Day 8 00 AM 62 Evening 6 00 PM 70 Night 10 00 PM 62 RESIDENTIAL 7 DAY PROGRAMMING MODE Setting the clock Touch the clock on the display The day of the week will flash Use the UP and DOWN arrows to adjust the day Touch the clock again The hour will flash Use the UP and DOWN arrows to adjust the hour If the time is PM adjust the hour until the PM symbol appears Touch the clock again The minutes will flash Use the UP and DOWN arrows to adjust the minutes Touch the clock again and the thermostat will resume normal operation Mode selection The T 21 P can control both heating and cooling Touch the Mode box to cycle through and select available modes Based on equipment and thermostat configuration mode selection can be as follows Mode Heat Fan selection Off Thermostat will not call for heating or cooling Heat Thermostat only controls heating When heating system is running Heat flashes Cool Thermostat only controls cooling When cooling system is running Cool flashes Auto Thermostat controls both heating and cooling Heat or Cool will flash when equipment is running E Heat Emergency heat for heat pump systems should the compressor fail Touch the Fan box to select Automatic or Always On fan mode In Automatic mode th
6. e fan operates with a heating or cooling call If set to Always On the fan will run continuously If the thermostat is turned Off while the fan is set to Always On the fan will switch to Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off Fan Autg atic Programming 4 daily events 7 individual days Touch and hold the Program box until the UP and DOWN arrows along with the flashing days of the week appear The program format starts with Monday You will now be able to program four schedules per day with individual heating and cooling setpoints for each day of the week If the Programmable Fan option is ON you may also program the fan operation for each scheduled event Touch the Program box again and the start time for the Monday Morning program will appear and the hour will flash Use the UP and DOWN arrows to adjust the Morning start time hour Touch the Program box again and the minutes will flash Use the UP and Down arrows to adjust the minutes in 10 minute increments Program Morning Touch the Program box again and the Morning Heat Set temperature will appear and flash Use the UP and DOWN arrows to change the heating setpoint Heat Set Ha Program Morning Touch the Program box again and the Morning Cool Set temperature will appear and flash Use the UP and DOWN arrows to change the cooling setpoint Repeat the same steps for the Day Evening and Night programs Aft
7. en based on thermostat configuration Time and Day only shown in i programmable mode Touch to set day and time Space temperature always displayed Fan Mode Touch to select Touch to select py Program Heat Cool Auto ways On only shown in Off or E Heat operation programmable mode To override programmable mode touch the Program icon until Hold appears This will allow manual operation of the thermostat Touch the Hold icon until Program appears to resume programmable mode BASIC FUNCTIONS Some symbols and display functions are normally hidden from view until needed or may not appear based on the thermostat configuration Make sure your contractor configures the T 21 P to suit your specific needs Fit Filter Optional filter reminder alternates with the current time Reset by touching both Mode and Fan Clean Screen Touching this button when shown will lock out all thermostat functions for 30 seconds to permit cleaning the display screen Up and Down Arrows Used to set temperature time day of week and other values Vv Lock Padlock symbol indicates that the selected function is prohibited or the setpoint limit has been reached Battery Shown when battery needs to be replaced RESIDENTIAL 5 2 DAY PROGRAMMING MODE Setting the clock Touch the clock on the display The day of the week will flash Use the UP and DOWN arrows to adjust the day Touch the clock again The hour will
8. er the Night Cool Set temperature is confirmed touch the Program box again and the copy symbol will appear If you wish to copy the Monday schedule to additional days of the week use the UP and DOWN arrows to select each additional day For example you might want to copy the Monday schedule to Tuesday and Wednesday Once you have selected the days touch the Program key and the copy symbol will flash confirming that the Monday schedule has been copied to the additional days selected Touch the Program key again and programming will commence with the next non scheduled day which in the example would be Thursday Mon Tue Wed Program To skip the copy feature and advance to the next day simply press the Program key after the copy symbol appears You can program a different schedule for each day of the week The factory default schedule is the same as the 5 2 programming mode COMMERCIAL PROGRAMMING MODE Setting the clock Touch the clock on the display The day of the week will flash Use the UP and DOWN arrows to adjust the day Touch the clock again The hour will flash Use the UP and DOWN arrows to adjust the hour If the time is PM adjust the hour until the PM symbol appears Touch the clock again The minutes will flash Use the UP and DOWN arrows to adjust the minutes Touch the clock again and the thermostat will resume normal operation Mode selection The T 21 P can control both heating and cooling Touch the
9. ing a of the week appear The program format starts with Monday through Friday You will now be able to program four schedules per day with individual heating and cooling setpoints for all five days of the week If the Programmable Fan option is ON you may also program the fan operation for each scheduled event Mon Tue Wed Thu Fri Touch the Program box again and the start time for the Morning program will appear and the hour will flash Use the UP and DOWN arrows to adjust the Morning start time hour Touch the Program box again and the minutes will flash Use the UP and Down arrows to adjust the minutes in 10 minute increments Program Morning Touch the Program box again and the Morning Heat Set temperature will appear and flash Use the UP and DOWN arrows to change the heating setpoint Heat Set Program Morning Touch the Program box again and the Morning Cool Set temperature will appear and flash Use the UP and DOWN arrows to change the cooling setpoint Repeat the same steps for the Day Evening and Night programs After the Night Cool Set temperature is confirmed touch the Program box again and Saturday and Sunday Sat Sun will flash Repeat the same steps for the Saturday and Sunday programs After the Saturday and Sunday Night Cool Set temperature is confirmed or Programmable Fan if used the thermostat will resume normal operation in approximately 20 seconds All scheduled events will be saved in non vol