Home

micronet - Southwest Microwave, Inc.

image

Contents

1. uf N ICE MICRONET Perimeter Security System RONET k E The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience It is a sophisticated perimeter security system which provides precise location of alarms MICRONET is based on MicroPoint cable technology which detects any fence disturbance and locates it to within 10 feet Precise location allows proprietary digital signal processing DSP algorithms to detect any attempt to cut or climb the fence while ignoring distributed noise from wind rain or heavy vehicles Reliable detection is assured MICRONET also transmits alarm signals and operating power to all MICRONET modules and auxiliary sensors along the perimeter eliminating the need for extra wiring MICRONET software interfaces directly with a per sonal computer PC so that your computer becomes the installation test set graphic map and alarm monitoring display Installed cost is very low Best of all MICRONET was designed by Southwest Microwave and it is backed by our 30 years experience with exterior security systems around the world Features p MicroPoint Detection with location to 10 feet B Sensitivity Leveling for varying fence conditions p Free Format Zoning eliminates hardware constraints in system design B Point Impact Discrimination increases detection withou
2. Link Units terminate the detection process and provide a means of interconnecting multiple Signal Control Units They are used at the ends of the A and B MicroPoint cables They also provide terminals to interface to auxiliary Sensors Size 35 5L x 30 5W x 15 3H cm 14 x 12 x 6 in Weight 7kg 15 5 Ibs Operating Temperature 40 C to 70 C 40 F to 159 F Inputs 2 MicroPoint cables 4 Isolated contacts Outputs 12 VDC at 150 ma for auxiliary sensors and devices optional with Power Converter Card Optional Isolated Link Unit Used on larger systems please consult factory Termination Unit The Termination Unit is used at the end of line in an open loop configuration to terminate detection process Size 7 6L x 6 4W x 13 3H cm 3 0 x 2 5 x 5 25 in Weight 0 45 kg 1 Ib Operating Temperature 40 C to 70 C 40 F to 159 F Inputs 1 MicroPoint Cable Network Interface Module The Network Interface Module provides interface points for external connections to data and graphic displays This module provides RS232 and RS422 RS485 data ports for external communications and real time clock This module plugs into any Signal Control Units Operating Temperature 40 C to 0 C 40 F to 159 F Outputs RS485 to Relay Module RS232 or RS422 to PC modem Real time clock RS422 to Converter Southwest Microwave Inc Relay Module Relay Modules communicate via RS485 to the Signal Control Unit with a Netw
3. p Remote diagnostics Modem interface reports site conditions and alarm information over ordinary telephone lines This fea ture allows for remote trouble shooting MICRONET MICRONET MICRONET MICRONET s major components are the Signal Control Unit MicroPoint cable and Windows software The Signal Control Unit provides the system intelligence to perform powerful signal processing DC power distribution and data communications networking The MicroPoint cable permits the easy connection of the perimeter system provid ing DC power data communication for alarms and control as well as an intrusion detection sensor The MICRONET Perimeter Manager software included provides site de sign step by step installation and graphic map display Principle of Operation The signal control unit sends a pulse down the MicroPoint cable The pulse is reflected back by a disturbance provid ing location of the intrusion along the length of cable The received signal is sampled to create a signature which describes the reflected pulse Digital Signal Processing DSP allows MicroPoint sensor to measure the location and shape of the reflected pulse The microprocessor recognizes the shape of the response from a point target cutting or climbing and distinguishes it from responses caused by distributed signals such as rain wind and vehicle traffic The installer uses any PC to calibrate the MicroPoint cable sens
4. 86 75 O07 05 7 06
5. Microsoft Corporation Specifications subject to change without notice MICROWAVE Southwest Microwave Inc www southwestmicrowave com 9055 South McKemy Street Tempe Arizona 85284 2946 USA e Telephone 480 783 0201 FAX 480 783 0401 European Offices Southwest Microwave Ltd e Suite 1 Deer Park Business Centre Woollas Hill Eckington Pershore Worcestershire WR10 3DN UK e TEL 44 0 1386 75 15 11 FAX 44 0 1386 75 O07 05 7 06 MICRONET Perimeter Security Systems System Specifications p MicroPoint Detection locates intrusions to within 3 meters 10 feet Point Impact Discrimination recognizes and suppresses distributed disturbances due to wind rain and vibrations Ee Sensitivity Leveling automatically compensates for fence variations to equalize entire perimeter Ea Free Format Zoning allows the zones to be set in software independent of cable length or equipment location ie MicroPoint cable provides detection power distribution and data communications for the entire system ee Windows based MICRONET Perimeter Manager with Drawing Tool and Installation and Service Tool included ie MICRONET Map software with precise intrusion location displayed in color graphics ae Auxiliary sensors and devices are powered and controlled by the system See Each Signal Control Unit protects up to 1310 Feet 1 4 mile 400 meters of perimeter p Multiple Signal Control Units can be connect
6. ed together for larger lengths of perimeter Ee Operating voltage range 10 5 60 VDC ae Temperature range 40 C to 70 C 40 F to 159 F System Components Signal Control Unit Each module processes data from two lengths of Micro Point cable A and B Each length of transducer cable can be up to 200 meters 650 ft long Both A and B lengths of transducer cable are terminated in either Link Units or Termination Units Size 35 5 L x 30 5 W x 15 3H cm 14 x 12 x 6 in Weight 7 kg 15 5 Ib Operating Temperature 40 C to 70 C 40 F to 159 F Power 10 5 to 60 VDC at 3 5 watts without auxiliary sensors 12 VDC at 580 ma 24 VDC at 260 ma and 48 VDC at 160 ma Inputs 2 MicroPoint cables A and B 6 Dry contacts inputs 3 Analog inputs 0 5 V 4 Alarms and 2 Tampers from the Link Units over the MicroPoint cable Outputs 3 Alarm relays SPDT Form C 2 amp 28 VDC 12 VDC at 150 ma for auxiliary sensors Communications port for computer or relay models with optional 232 or 422A Adapter MicroPoint Cable MC 115 The MicroPoint cable is used for detection power distri bution and data communications MC 115 Type Size 4 902 mm 0 193 in diameter Jacket High density polyethylene UV resistant black Operating Temperature 40 C to 70 C 40 F to 159 F Minimum Bend Radius 10 cm 4 in Packaged Roll Size Weight y P 100m 328 ft 4kg 9 Ibs 200m 656 ft 8kg 18 Ibs A PO Link Unit
7. ems Difficult to locate problems Free Format Zoning YES Software Controlled Zones NO Hardware defined zones Y Multiple zones per cable NO Only 1 zone per cable Y Easy to add zones Requires more processors Y Easy to change zone boundaries Requires reinstallation Point Impact Discrimination YES Recognizes local disturbances NO Responds equally to all disturbances Y Ignores noise from wind rain NO Sensitivity to wind rain vehicles MicroPoint cable with Integrated Power and Data YES Power amp Data Superimposed NO Separate power amp data wires on Transducer Cable Y One cable carries all Additional material amp labor Y Secured by the sensor Requires conduit to secure Y Supports auxiliary sensors Separate power and data required MICRONET Communications YES Built in FSK network NO Separate wiring required Y Peer to peer network Separate wiring from each sensor Computer Aided Installation YES Windows based Installation and NO User Manual is rarely read often lost Service Tools 4 Install it right the first time Costly repairs Y Well documented sites NO Documentation is lost or never read Y Telephone maintenance amp diagnostics Many unnecessary trips to site remote upload download capability MICRONET technology is patented by Southwest Microwave Inc US 5446446 e MICRONET and MicroPoint are trademarks of SOUTHWEST Southwest Microwave Inc and Windows is a registered trademark of
8. or and assign zones During calibration the sensitivity MicroPoint Sensor Detection Concept MicroPoint Cables Perimeter Monitor Operator Graphic Display of each 3 ft of cable is set to provide uniform sensitiv ity along the entire length of MicroPoint cable In fence installations Sensitivity Leveling accommodates varia tions in the type of fence fabric and in the fabric tension Zones are user defined from the keyboard Free Format Zoning allows the number and location of zones to be easily altered to meet changing site conditions Windows based installation software provides installation guidance and records as installed details for later maintenance and diagnostic purposes K intrusion Pulse ee Response TTI Z MICROPROCESSOR iat se Digitized pesnunee Range Cells Filtered Response L Ai SOUTHWEST MICROWAVE Intrusion Location MICRONET OTHER SENSORS MicroPoint Detection and Assessment YES Locates alarms within 10 feet NO Only detects presence Y Intruder stands out from wind rain NO Intruder buried in wind rain Y Digital processing increases Pd External processors required Y Focused CCTV assessment Many more processors needed Sensitivity Leveling YES Calibrated every 3 feet NO One threshold for entire zone Y Compensates for fence variations Often requires fence work Y Calibration optimizes Pd vs FAR NO Pd vs FAR compromised Y Easy to locate probl
9. ork Interface Module It provides both NO and NC relay contacts and analog channels for external alarm panels auxiliary controls or remote devices Multiple Relay Modules can be connected up to 10 to the RS 485 line Size 33 7 x 12 7 x 13 9H cm 13 25 x 5 x 5 5 in Weight 1 36 kg 3 Ibs Operating Temperature 40 C to 70 C 40 F to 159 F Power 10 5 to 13 VDC at 2 0 watts 110 ma Inputs 6 Dry contact inputs 4 Analog Inputs O 5 VDC RS485 from Network Interface Module Outputs 6 Alarm Relays SPDT Form C 2 Amp 28 VDC 12 VDC at 150 ma for Auxiliary Sensors and devices optional with Power Converter Card Accessories Bm Heavy Duty DC Power Supplies MicroPoint Cable Splice Kit 232A or 422A Adapter for Communication Connection p Power Converter Card Options amp Multiple Map Graphic Display amp Control Software Armored MicroPoint cables available MICRONET and MicroPoint Cable are trademarks of Southwest Microwave Inc and Windows is a registered trademark of Microsoft Corporation Specifications subject to change without notice Aii SOUTHWEST MICROWAVE www southwestmicrowave com 9055 South McKemy Street Tempe Arizona 85284 2946 USA e Telephone 480 783 0201 e FAX 480 783 0401 European Offices Southwest Microwave Ltd e Suite 1 Deer Park Business Centre Woollas Hill Eckington Pershore Worcestershire e WR10 3DN UK e TEL 44 0 1386 75 15 11 FAX 44 0 13
10. t increasing nuisance alarms p MicroPoint cable with integrated power and data for reduced installation costs B Windows based PC installation A SOUTHWEST MICROWAVE MICRONET Perimeter Security Systems System Description MICRONET MicroPoint cable is tie wrapped to a chain link fence where it detects vibrations from any cut or climb and precisely locates the point of intrusion MicroPoint cable transmits alarm data and system status to each MICRONET module and provides power to these modules and auxiliary sensors along the perimeter No other equipment or wiring is needed Precise location of each fence disturbance provides p Point Impact Discrimination Sensitive to a localized fence disturbance caused by a cut or climb Insensitive to distributed fence noise due to wind rain and nearby vehicles p Sensitivity Leveling Calibration automatically compensates for fence varia tions Each meter of perimeter fence is equally sensitive to intrusions l MICRONET MICRONET p Free Format Zoning Zones are set from the keyboard independent of processor location and may be changed at will Built in microprocessor and PC software provide p Windows based installation program Installation and service is completed with easy to use graphic tools Graphic annunciator map User drawn site map is converted into a basic graphic annunciator map No other multiplexer or map display system is needed