1. CAUTION o Miuswireing the input or output connectors may damage the unit o Exceeding the ratings for current voltage and temperature may damage the unit o Use only as directed to prevent personal injury and damage o Avoid touching components as static discharge may damage them INTRODUCTION This low voltage disconnect LVD 1s basically an electronic switch that automatically disconnects the battery from the product using the battery load It is used to prevent damage to either the battery from over discharge or the load from a low operating voltage These conditions usually occur in backup applications during an AC power failure with the load running off the backup battery or in portable applications where AC power is not available W Wen LOW VOLTAGE DISCONNECT Alarm versions are available that provide an audible and or visual warning before disconnecting the battery Models are available covering a wide range of lead acid nickel cadmium and nickel metal hydride batteries If used in a system with a battery charger once the battery is about 50 charged the LVD will automatically reconnect the battery to the load INSTALLATION Due to wire resistance the voltage at the load will be lower than at the battery This effect is more pronounced at higher currents with smaller gage wires and with longer wire runs Because of this location plays a roll in how to best implement the low voltage disconnect in your applicat
2. DECR INCR DISCONN VOLT ADJ EGUN OPTIONAL REMOTE RED LED ACCESSORY Xenotronix TLI Inc 5 DP10 DP20 User s Manual Hook Up Summary To summarize the BATT and BATT terminals on the LVD must be attached to the battery to power the circuit The negative load wire must be attached to the LOAD terminal on the LVD The positive load wire is normally attached directly to the positive battery terminal preferred for high current applications however it may be connected to the LOAD terminal on the LVD if it is more convenient If the LOAD terminal is used the full load current will flow through the wire connecting the BATT terminal to the battery so that wire must be sized to handle the full load current as well For the best performance the shortest length and largest gage hook up wires should be used OPERATING INSTRUCTIONS Once the LVD is properly connected to the load and battery operation is automatic When first attached to the battery the LVD circuit defaults to a connected status and the BATT and LOAD terminals are connected to each other If the battery is discharged down to the disconnect voltage the LVD will wait 3 seconds to make sure it 1s not a transient condition before disconnecting the load While in a disconnected state the LVD will draw a small quiescent current to operate the circuit Alarm ve
3. This wire must be sized for the full load current The LOAD terminal is an optional connection point for connecting the positive load wire if the positive battery terminal is not convenient If used it will draw the full load current from the battery through the BATT terminal and both wires must be sized for the full load current The BEEPER header is for connecting the optional remote beeper accessory if using a remote alarm version of the LVD Small gage wires may be used The LED header is for connecting the optional remote LED accessory if using an alarm version of the LVD Small gage wires may be used Recommend Wire Sizes Wire manufacturers rate the current carrying capacity of wire based on a safe temperature rise for the insulation However these ratings do not account for the voltage drop caused by high currents and the resistance of the wire We recommend the following wire gages Load Current Wire Size Load Current Wire Size 0 to 4 Amps 18 AWG 11 to 15 Amps 12 AWG 4 to 7 Amps 16 AWG 15 to 20 Amps 10 AWG 7 to 10 Amps 14 AWG Hook Up Diagram REMOTE BEEPER ACCESSORY NEG J y BATT NEG NEG to LOAD IS FEAN BATTERY LOAD gt BATTERY CHARGER O D a SIG o SIG POS D POS POS
4. DP10 DP20 User s Manual A XENOTRONIX BRAND Models DP10 amp DP20 Series Low Voltage Disconnects User s Manual Rev 1 1 October 31 2007 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLl Inc 2541 Tracy Road Toledo Ohio 43619 Phone 419 666 6982 Fax 419 666 6534 Xenotronix TLI Inc 1 DP10 DP20 User s Manual Warranty Seller warrants that its products Product s will meet the specifications set forth in its catalog from time to time unless the Buyer is notified otherwise prior to delivery Seller will without charge repair or provide a replacement for any of the Products which prove to be defective in materials or workmanship within one 1 year from the date of shipment Warranty Period If within the Warranty Period Buyer discovers a defect in materials or workmanship which interferes with the operation of any Product Buyer must promptly notify Seller in writing of such defect Seller s sole obligation to Buyer under this Warranty is to repair and correct any defect in material or workmanship or provide a replacement Product to Buyer Seller s decision with respect to the applicability of this Warranty to any defect shall be final and conclusive Seller reserves the right to require Buyer at Buyer s sole cost and expense to return any defective Product including any alterations made thereto F
5. O B Seller s factory in Ohio Seller does not warrant against abrasion corrosion or erosion Seller shall not be liable to Buyer or to any other person for work done or repairs made to remedy any defect by any person who is not an authorized representative of Seller unless Seller s written consent is first obtained by Buyer This Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the subject of improper storage installation or operation c is the subject of intentional or negligent misuse misapplication neglect or accident or d is not used repaired or altered in accordance with Seller s written instructions Seller expressly reserves the right to declare this Warranty null and void upon Buyer s failure to make full and timely payments with respect to any Products purchased by Buyer from Seller in which event all of Seller s obligations and Buyer s rights under this Warranty shall immediately terminate SELLER DISCLAIMS THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTIES ARISING FROM COURSE OF PERFORMANCE COURSE OF DEALING OR USAGE OF TRADE SELLER SHALL NOT BE LIABLE TO BUYER OR ANY OTHER PARTY UNDER THIS WARRANTY FOR DIRECT SPECIAL CONSEQUENTIAL INDIRECT OR INCIDENTAL DAMAGES OF ANY KIND Notice to the User The information cont
6. OZ LOAD J 1 LOAD ALLOW AN ADDITIONAL 0 5 1 INCH IN 1 00 2 05 HEIGHT FOR QUICK DISCONNECTS AND WIRING CLEARANCE Refer to the DP10 amp DP20 Application Notes document available on the website for more detailed information on topics discussed in this manual and additional important information about using your LVD and its available features and options Xenotronix TLI Inc 9
7. ained in this manual is believed to be correct However Xenotronix TLI Inc assumes no responsibility for any inaccuracies therein Information in this manual is subject to change without notice No part of this manual may be reproduced or transmitted in any form electronic or mechanical for any purpose without the express written permission of Xenotronix TLI Inc Copyright 2007 Xenotronix TLI Inc All rights reserved Xenotronix TLI Inc 2 DP10 DP20 User s Manual TABLE OF CONTENTS Models DP10 amp DP20 Low Voltage Disconnect User s Manual PE CUO ss rato at ito Ne Ra l Irsa AA A E O E O ETE EE TE E ET l Product PNOO AAA l A eS o A l FOO KS Oi capt E O E TE 2 3 TOMNA S ot dan ia de Veet E R RT N aA 2 Recommended Wire SIZES ea Rg R Reg Ra RRR RRR ooo 2 Hook Up Digctanl estaa ed a da id aia 2 a Is A E a E E ng es 3 Operating INSHUCHONS eres cried e a 3 LVD Operation Notes and TDS isa as 3 4 CUSO MMS at a Stereo tok es ia 5 Battery Charger Specifications xs e e e e e e e cece ee eens 6 IR as A A A eas a A E Ea 6 Xenotronix TLI Inc 3 DP10 DP20 User s Manual SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for DP10 amp D20 Low Voltage Disconnects Before using the low voltage disconnect please read this manual and all instructions and cautionary markings on the battery the product using the battery and 1f using a battery charger the battery charger
8. ation disconnect the battery from the LVD and all connected equipment while in storage or use a float charger Xenotronix TLI Inc 7 DP10 DP20 User s Manual MODIFIED CUSTOM UNITS Xenotronix TLI Inc can modify our standard products or make custom units to exactly match your specifications Call our sales department for technical information and pricing on modified and custom units or to see 1f another unit will work in your application These are some of the modifications we can make to our standard units O Set the disconnect voltage to your specification Set the reset voltage to your specification Calibrate for different battery types Extended temperature operation Make changes to timers or other program operations Supply hook up wires and connectors Custom enclosures Private labeling minimums may apply Xenotronix TLI Inc 8 DP10 DP20 User s Manual LOW VOLTAGE DISCONNECT SPECIFICATIONS General Conditions 25 C 77 F Maximum Continuous Current Maximum Surge Current 5 sec Standard Disconnect Voltage Custom Disconnect Voltage 0 6 to 1 2 V cell 1 5 Standard Reset Voltage 1 3 V cell 3 Battery Available Models 6 to 24 V 5 20 cells DIMENSIONS 0 250 X 0 032 TABS 4 PL 20 166 BATT No E 2 05 lt 050 e BATT LOAD LOAD EE TE Car E O E WEIGHT APPROX 2
9. attery charger is rated for at least twice the load current so that there will be adequate current available to finish charging the battery once the load is automatically reconnected Xenotronix TLI Inc 6 DP10 DP20 User s Manual The battery should be recharged as soon as practical after the LVD has disconnected the load this will help prevent damaging sulfation At this point all of the useful capacity of the battery should have already been used and attempting further discharging will almost certainly cause battery damage Connect a battery charger directly to the battery and not through the LVD terminals because the battery charger may be rated for a higher current than the LVD terminals or the wires connecting the LVD to the battery The LVD may be left connected to the battery in parallel with the battery charger without damage If installing a fuse or circuit breaker to protect the load battery LVD or the wiring from overload conditions it should be located as close to the battery the source of the energy as practical Reversing the BATT and BATT input power connections will damage the unit If the BATT and LOAD connections are reversed it may appear that the unit is functioning normally however when the LVD attempts to disconnect the battery it will be damaged Double check all wiring before making the final battery connection The LVD can not be used in common negative ground applications such as using a metal
10. chassis to make common negative connections The LVD must be able to break the path between the negative battery terminal and the negative load terminal An exception 1s if the LVD is used to control a relay that is then used to control the positive connection When using the LVD in a system with a relay as the relay coil magnetic field collapses it can generate a voltage spike of several hundred volts that will damage the LVD If the relay does not already have a catch diode added to prevent this voltage spike from occurring 1t must be added The diode must be very fast to prevent the spike general purpose diodes are not sufficient In some types of motor load applications disconnecting the battery while the motor is operating may cause the motor to act as an unregulated generator This could allow the voltage to fly up causing current to flow in the reverse direction In most applications the battery will filter the voltage spike and protect the LVD and other connected equipment In some applications where the motor has a lot of stored energy the reverse current may be significant enough to damage the LVD or other equipment To prevent a damaging reverse current flow a diode must be installed near the motor The diode must be adequately rated to handle the motor operating current as well as the voltage spike To prevent parasitic loads including the LVD itself from discharging the battery and potentially damaging the battery from sulf
11. ion If the main purpose of using the LVD 1s to protect the battery while obtaining the maximum discharge locate the LVD as close to the battery as possible shortest wire runs located between the LVD and the battery This will minimize the voltage drop in the leads between the battery and the LVD and the voltage the LVD sees will be closer to the actual battery voltage If the main purpose of using the LVD is to protect sensitive equipment from potentially damaging low voltage conditions locate the LVD as close to the equipment as possible In both cases the battery will be protected from a damaging over discharge condition Mount the LVD using a no 8 screw through the mounting hole in the center of the LVD The LVD may also be mounted using double sided tape Mount inside an enclosure or use a protective cover to prevent mechanical damage Xenotronix TLI Inc 4 DP10 DP20 User s Manual HOOK UP Terminals The BATT terminal is used to power the LVD and monitor the battery voltage A small gage wire may be used however if the LOAD terminal is used to connect the load then a wire sized for the full load current must be used The BATT terminal is used to power the LVD monitor the battery voltage and is also the path for the full load current to flow into the LVD from the battery This wire must be sized for the full load current The LOAD terminal is the path for the full load current to flow out of the LVD and into the load
12. rsions will indicate a warning for approximately 60 seconds and the low voltage condition must be maintained for 60 seconds before the LVD disconnects the load The alarm will reset if the low voltage condition 1s removed for a continuous 3 seconds during the alarm If using an LED indicator alarm versions will draw slightly more quiescent current after disconnecting WARNING This LVD has an automatic reconnect feature When charging the battery once it has been charged to approximately 50 of capacity the LVD will automatically reconnect the load This may cause unexpected operation of the equipment If this will cause a problem with the load or it is a safety issue then do not charge the battery with the LVD connected or use a separate switch to disable the load during charging LVD OPERATION NOTES AND TIPS When the LVD is not connected to a battery the default condition between the BATT and LOAD terminals is disconnected As soon as the LVD is powered even at a voltage below the disconnect voltage the battery and load terminals are automatically connected until the LVD runs through a normal disconnect cycle For longer battery life once the load is disconnected it should not be turned on again until the battery is fully recharged This will ensure the battery is adequately recharged between successive discharges This 1s especially important when using lead acid batteries If the load can not be controlled this way then make sure the b
Download Pdf Manuals
Related Search
Related Contents
Les camping chèques numériques 取扱説明書 [PDF形式] NVR Station User Guide Audiovox 9155-GPX Telephone User Manual ThunderION - Electrostatica Monster Duo - Performance Audio KEF Reference 205/2 Fujitsu PRIMERGY RX100 S6 MANUAL DE INSTRUÇÕES Copyright © All rights reserved.
Failed to retrieve file