Home

RS-Global system Tracking Server v.3.3.x. program User manual

image

Contents

1. Object ID Number witch will be used to display object in TrackingView program Type device type See p 2 3 Description Information field filled by user Object description Data life time s determines after what time received data and commands will be sent to archive If you need to register more than one object you have to use electronic USB dongle made by the Guardant Company This dongles and software for them are included into server package You can register objects only if dongle is inserted into USB port and ready for work In every dongle are assigned number of objects that user can register 2 5 1 Guardant dongle driver installation and remote programming 1 Driver installation First of all to avoid to avoid system conflicts and to ensure dongle stable work you have to install last version of Guardant drivers To do this 1 Start INSTDRV exe file witch is located in Drivers_ 4 88 directory 2 Press Install driver button in Guardant driver installation dialog window 3 Restart computer if necessary 4 Connect dongle to USB port 5 After connecting dongle standard New hardware wizard will appear You have to choose Automatic installation and press Next button 6 After searching and configuring Wizard will report that these drivers isn t signed by Microsoft Corporation and will recommend to abort installation To continue driver installation you have to press Continue anyway After
2. RS Global system Tracking Server v 3 3 x program User manual 1 2007 Table of contents EEE Aa ee 0 ENE ERE GE 3 2a DO WINGS EN EE 4 21 GENERAL parameter SEWING Senisi a 4 2 2 Archive parameter SettingS cccccccsssssscceesssssenseeceeecessesneeeceesseseseeseesessessseeeesessessseanaeseness D 2 3 Device type configuration and status assigning rrrrrrnvrrrnrnvrrrrrrarrrrnrnnrrrrrrnrrrrrnnnrrrrrnnrrrsrnnnnnn 6 24 SOUFCE template COMMOURAU OM syes S ES 7 2 NTN 7 2 5 1 Guardant dongle driver installation and remote prograMmMing ccccccccceceeseeeeeeeeeeeees 9 26 FE COMMENT 10 Ze VET CONAN 10 Ss NOK VM NOR 11 1 General information Tracking Server program is designed for information gathering saving processing and providing to user Program general window appearance is shown on Pic 1 Attention This program version is only compatible with_Tracking View_version_not less than 3 3 x Tracking server a SRA x File Monitoring Configuration Help El bn 15 k Start Stop Events Backup Archivate Last backup time 30 11 2005 10 26 29 Next backup time 03 12 2005 Last archive time 01 12 2005 13 42 12 Nest archive time 04 12 2005 Server RO Data accepting Data sending Listening port 900 Listening port 901 Connection count 1 1 Queue size Data Commands Control commands Text messages Object Latitude Longitude Last updated Server st
3. 3 information Object to witch command is sent Object sent command command time of command sending Time Text messages bookmark allows viewing text messages sent from object witch is in Offline mode in the way as they would be seen on mobile phone display Available information Object who sent the message Object message text Text time of message receiving Time To receive text messages GpsTsc program version must be at least 3 1 6 Attention Available command list see in manual for GSM GPRS GPS object module 2 Settings Server settings window can be opened through main menu Configuration settings 2 1 General parameter settings General parameter settings is made through Main bookmark See Pic 2 Main Archives name Device types Sources Objects Filters Data accepting Common Port 300 gg Connection life time Monitor port Session life time s Port 301 Message lite times Data Commands Control commands One client connection per user i Cancel Pic 2 General parameter settings window In Data accepting field is specified number of port through witch server will receive data from the objects In Monitor port field is specified number of port through witch server will connect with user Connection life time s determines the time after witch session will be closed if there is no activity Session life time s field determines the time during witch you can restart Tr
4. pooo IP Mask oo o To change user or group rights you have to press el icon and in i A i ser Qroups appeared window activate checkboxes near necessary rights ok User name Password Also you have to presin and specify ID s of an objects witch will be available for user to monitor and control With the help of icn you can change name and password of existing user User rights are added to group rights So if user has rights to modify archive but this function is forbidden to group than user will be able to modify archive anyway Cancel When you select a group in the window lower field will be shown a users that are included in that group When you select a user in the window lower field will be shown all groups where this user is included 3 Working with program All program control is made using icons that are located in general window upper part With the help of Start and Stop icons you can start or stop server With the help of Events icon you can see event log from the server start moment Using Backup icon you can activate data backup process Using Archivate icon you can move data to archive Attention When you are making data backup or sending data to archive timer nullification is made So next backup or archivation process will take place in time specified in program settings 2 days by default 11
5. window In Archivate block is configured data archive process algorithm Interval days determines time interval between archive processes Time determines archivation time Leave data for days determines after what time data will be sent to archive In Backup block is configured data backup algorithm Directory user can specify path to folder where backup copy will be stored Interval days determines time interval between two backup copies creations Time determines backup copy creation time 2 3 Device type configuration and status assigning Pic 4 Device type configuration window In this window are configured device types and statuses for them When pressingiic n add device type window will appear In this window you can specify following parameters gt Device bad fel es Name device type name Control commands checkbox when active allows sending control commands to the objects of this type Name Control commands When you press icon status assign window will de opened There you can choose necessary status color and assign event code which will activate this status There are 4 status types Each of them has their own color Status colors are fixed and cannot be changed Status 1 displayed in white color and by default used as Unknown status Status 2 displayed in green color and by default used as Armed status Status 3 displayed in pink co
6. acking view program without session interruption Fields combined into Message life times s block aren t used in this version of program and shouldn t be configured One client connection per unit checkbox when active doesn t allow two or more users to connect simultaneously if they have same login and password 2 2 Archive parameter settings Archive parameter configuration is made using Archives name bookmark See Pic 3 DB Parameters block data base parameters Local checkbox determines whether database will be saved on the same computer where server is installed or no In Host field is specified IP address of the computer where database will be stored This computer must have MySQL installed field isn t active if Local checkbox is activated Database field determines name of the directory where database will be saved Archives name field determines the name of the directory where archive will be saved It s not recommended to change Users and Password fields because it can cause problems with data base configuration Main Archives name Device types Source Object Filters DB Parameters Archivate Local Interval days Host ocalhost Time Database Tracking leave data tor days Archives name Tracking archive Users root Directory Password C Program Filas kK ork oh T r aml meh C ar ar th ack Dm Test Interval days 2 Time fo jo al Cancel Pic 3 Archive parameter settings
7. arted 9 36 06 Pic 1 Program general window Monitoring paragraph of the Main Menu allows receiving information about connections on both ports used by the program Data accepting column shows information about received data Status field shows number of port which is used for data receiving Connection count field shows number of communication channels Attention Data transmitting from object to server is made using connecting program GpsTsc GPRS connection MapTsc WinSC UHF connection or others Data sending shows information about sent data Status field shows number of port which is used for data sending Connection count field shows number of communication channels In information window that is located lower you can see information about objects and commands Data bookmark gives information about objects information from witch was received at least once during the session Available information Object ID Object object coordinates latitude longitude Latitude Longitude time of last data update Last updated object status moving stopped state Online Offline Flags object speed Speed ADC value ADC object movement direction Direction Commands bookmark shows information about commands received from objects Available information Object who sent command Object received command command time of command receive Time Control commands bookmark shows information about commands sent to objects Available
8. ecting appropriate parameter In the former case in new dialog window user must specify a path to the received update file in latter case additionally specify if answer was received in the form of hexadecimal number or file Number is entered in the appropriate field or file path is specified After that user gains access to the last dialog window where system informs about update procedure result 2 6 Filter configuration Filter configuration is made through Filters bookmark see Pic 6 E 2 x Main Archives name Device type Sources Objects Filters Enabled iv Max speed km h 200 Max acceleration km h per second a0 Max braking km h per second SU Statistic size 5 Minimal statistic matches 3 Pic 6 Filter configuration window To minimize invalid route points appearance in the archive program uses filter Filter works the following way Program extracts from archive number of route points set in the Statistic size field Every route point is compared to previous and verified if it fits into limitations specified in the Max speed km h Max acceleration km h per second and Max braking km h per second fields Minimal number of route points that fit into the limitations is specified in the Minimal statistic matches field Attention It is recommended to set Minimal statistic matches field value same as value of the_Statistic size field But it NEVER should be greater than value of the Statistic
9. lor and by default used as Disarmed status Status 4 displayed in red color and by default used as Alarm status 2 4 Source template configuration In this window is og source number for specified device rype Man Archives name Device types Sources Object Filters ID Device type 1 GSM a LIHF Cancel Pic 5 Source template configuration window When you press i on template configuration window will be opened There you should specify source number device type see p 2 3 and template description 2 5 Object configuration A x Main Archives inn Device Sources Objects Filters 1 37126475420 1 3000 test Syg 3 520 3 3000 UHF 3 630 999 4000 UHF l Cancel Pic 5 Object configuration window Object configuration is made through Objects bookmark see Pic 5 In this window you have to assign all objects that will be connected to sever To do this you i have to press icon Object registration window will appear Object configuration Ioj x Source fe Device ID 37126475420 Object ID 1 Type GSM Description test 0 Data life time s foo 4 i Cancel Pic 6 Object registration window Source ID Number of channel that will be used to connect with object Must be same as assigned in GpsTsc MapTsc or WinCS programs Device ID Object phone number or ID if UHF module Phone number must be with international code
10. size field or else all the route points will be deleted 2 7 User configuration users Tracking server program has authorization system that consists of user name and password If no user is registered program works with minimum rights You can add user through main menu Configuration Users User window will open Also in this window you can create groups of users with common rights When you add a user into the group he automatically receives all group rights To create group you have to pre icon and in appeared window enter group name After name confirmation group rights assignment window will appear To add a user you have to press icon Add user window will appear There in User name field you have to specify user login and then press icon to set password In IP Network and IP Mask fields you can specify user s IP address and or subnet mask If user will try to login from a different IP or mask he will be ignored If any bit of the IP or mask will be set 0 than this bit won t be analysed If all 4 bits are 0 it means that user can connect to server from any IP or mask Pic 7 User configuration window 10 User properties In the lower field you can choose one or more groups where user will be included If no group is selected than user won t be included in any After accepting user details user rights assignment window will appear Later user and group rights can be changed NREN
11. that driver installation will be finished 7 If dongle drivers were correctly initialized by operating system green light will appear on the dongle Also dongle should appear in the Windows Device manager s list Attention It s recommended to repeat articles 4 7 separately for each USB port of the computer 2 Dongle memory remote programming For whole or partial dongle memory programming you have to start GSREMOTE exe utility Attention During work with utility programmable dongle must be inserted into USB port After start you will see program start window where you have to choose whole or partial dongle s memory contents and press Next button Utility will generate question number witch you have to send to secured software provider using phone or e mail After that if you don t expect the answer soon you can finish working with program by pressing Finish button When software provider receives question number he makes necessary changes in the mask file and receives answer in the form of a number or update file according to update method and sends it back to user If program work session was finished user must start program once again choose necessary option and in next dialog select Process number answer received from software vendor selected by default If work session wasn t canceled just press Next button Than user must specify if he s programming whole dongle memory or just a part of it by sel

Download Pdf Manuals

image

Related Search

Related Contents

Homelite GS120V Trimmer User Manual  取扱説明書 - M    地域限定募集!加盟店概要資料  Service Manual  

Copyright © All rights reserved.
Failed to retrieve file