Home
Installation and User Manual Havanna D
Contents
1. Heaters installation Heater safety distances and sensor position to wall Sensor installation Sensor installation Location for the connection box Wiring diagram Wiring diagram when Digi 1601 12 is used as control panel Wiring diagram when OT 2 PS 3 or OT 2 PUi is used as control panel Exploded view diagram of the heater Safety clearances Cable and Fuse Spare parts for Havanna D Page 08 oo oO NO O0 oo D I A A WwW WwW WwW 10 11 12 13 14 oo Co oo N A 10 10 11 12 13 Installation and User Manual Havanna D 3 1 Quick instructions for use of the sauna heater 1 1 Check before taking a sauna bath 1 The sauna room is suitable for taking a sauna bath 2 The door and the window are closed 3 The sauna heater is topped with stones that comply with the manufacturer s recommendations the heating elements are covered with stones and the stones are piled sparsely NOTE Ceramic rocks are not allowed A pleasant smooth sauna bath temperature is about 70 C degrees Rearrange the sauna stones at least once a year and replace any weathered stones This enhances air circu lation between the stones which extends the useful life of the heating elements If you encounter any problems please contact the manufacturer s warranty service shop For additional information about enjoying a sauna bath please visit our website at www helo fi 1 2 Operation of the sauna heater controls The main switch is
2. SEPC 93 4 5207680 230V 1500W 3 Heating element SEPC 94 4 4316229 230V 2000W 3 Heating element SEPC 95 4 4316230 230V 2670W 3 Heating element SEPC 96 4 4316231 230V 3000W 3 Table 3 Spare parts for Havanna D Installation and User Manual Havanna D 4 ROHS Ymp rist nsuojeluun liittyvi ohjeita T m n tuotteen k ytt i n p tytty sit ei saa h vitt normaalin talousj tteen mukana vaan se on toimitettava s hk ja elektroniikkalaitteiden kierr tykseen tarkoitettuun ker yspisteeseen Symboli tuotteessa k ytt ohjeessa tai pakkauksessa tarkoittaa sit Valmistusaineet ovat kierr tett viss merkint ns mukaan K ytettyjen laitteiden uudelleenk yt ll materiaalien hyd ynt misell tai muulla uudelleenk yt ll teet arvokkaan teon ymp rist mme hyv ksi Tuote palautetaan ilman kiuaskivi ja verhouskivi kierr tyskeskukseen Tietoa kierr tyspaikoista saat kuntasi palvelupisteest Anvisningar f r milj skydd Denna produkt f r inte kastas med vanliga hush llssopor n r den inte l ngre anv nds Ist llet ska den levereras till en tervinningsplats f r elektriska och elektroniska apparater Symbolen p produkten handboken eller f rpackningen refererar till detta De olika materialen kan tervinnas enligt m rkningen p dem Genom att teranv nda nyttja materialen eller p annat s tt teranv nda utsli
3. cuts power off the sauna heater Installation and User Manual Havanna D 10 Image 7 Location for the connection box 2 10 Location the connection box for connection cable in the sauna room A Specified minimum safety clearance 1 Recommended location for the connection box 2 Silumin box recommended in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles When installing the connection box to zones 2 or 3 refer to the instructions and regulations of the local energy supplier 2 11 Wiring diagram Teho Effekt L mp vastukset V rmeelement Tennid Input Potencia Heating elements Heizeelement Resistores Leistung Moc Termicos El amp ments chauffants Elementy V imsus Wejscie grzewcze T3Hb Puissance SEPC 93 SEPC 94 SEPC 95 SEPC 96 3000W 4 900 04 400V 415V 3N 354 SKSO 32 A Image 8 Wiring diagram Installation and User Manual Havanna D 2 12 Principle image when Digi 1601 12 is used as control panel Connector strip Limiter penecnanancnenecennannnannmenenemmnemen prmmmmnnnnnngfnnnnnnnnnannnnnnnnnnnnnennnnnnnnnnnnnnenn Contactor box 4a RAN Sensor cable 3 2 White 3 Red ee en Control panel Contactor box 4601 2812 i Eye
4. instructions THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREM ISES FOR THE FUTURE USER 2 6 Preparing for sauna heater installation Check the following before installing the sauna heater 1 The ratio of the heater s input kW and the sauna room s volume m Volume input recommendations are presented in Table 1 on page 9 The minimum and maximum volumes must not be exceeded 2 The sauna room ceiling must be min 1900 mm high Uninsulated and masonry stone walls extend the preheating time Each square metre of plastered ceiling or wall surface adds 1 2 m to the sauna room s volume 4 Check page 9 Table 2 section for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question 5 Conform to the specified safety clearance around the sauna heater There should be enough room around the sauna heater for maintenance purposes a doorway etc 2 7 Installation Follow the safety clearance specifications on page 9 when installing the sauna heater Thin panel is not a suitable mounting base The mounting base must be reinforced with timber behind the panel The minimum clearances specified on page 9 table 1 must be followed also in case the sauna room wall materials are incombustible Walls or ceilings must not be clad with fibre reinforced plaster board or other light weight cladding because they may cause a fire hazard A single sauna heater i
5. 1 1 EN GE BY 033 og A oa Ba gs i sjo i I a i lt z A1 Valk Vit White Weiss B1 Rosa Ljusr d Pink Rose A2 Ruskea Brun Brown Braun B2 Sin Bl Blue Blau A3 Vihre Gr n Green Fr n B3 Pun R d Red Rot A4 Kelt Gul Yellow Gelb B4 Musta Svart Black Schwarz A5 Harm Gr Grey Grau B5 Violetti Violett Violet Violett Control panel OLET 19 Silicone 4 x 0 25mm _ LiYY 10 x 0 25mm Sauna heater Contactor box WE3 Power supply 400V 415V 3N Image 9 Wiring diagram when Digi 1601 12 is used as control panel Installation and User Manual Havanna D 12 2 13 Principle image when OT 2 is used as control panel Control panel Connector strip Limiter OT 2 PS 3 or OT 2 PUi Pe ee nnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 472 l Sensor cable a 2 White a 3 Red 4 Yellow Sensor OLET 6 1 Silicone 4 x 0 25mm Control panel OT 2 PS 3 Power supply 400V 415V 3N Sauna heater Image 10 Wiring diagram when OT 2 PS 3 or OT 2 PUi is used as control panel Installation and User Manual Havanna D 13 1 4 Image 11 Exploded view diagram of the heater 3 Spare parts for Havanna D electric sauna heater Havanna Havanna Havanna Havanna Parts Product number Product title 450D 600 D 800 D 900 D 1 4069013 Havanna basic grate 1 1 1 1 2 7712000 Cable clamp NKWA 1 1 1 1 1 3 7812550 Mains connector NLWD 1 1 1 1 1 1 Heating element
6. g the for the sensor when using the contactor control panels 1418 2 1517 3 OT 2 PS 3 and casing WE 3 and the Digi 1 or 2 1418 2 1519 OT 2 PUi control panel Sensor OLET 19 The sensor must not be installed on the wall when using the Havanna D Heater Image 5 Sensor installation Image 6 Sensor installation Installation and User Manual Havanna D Power Saunaroom Minimum distance to Stone Volume Height Side In front Ceiling Floor wall of min max min max A D K B J Circa Circa kW m m min mm mm mm mm mm mm mm kg kg 4 5 3 6 1900 40 80 1100 120 135 245 20 28 6 0 5 9 1900 45 100 1100 120 140 245 20 35 8 0 8 12 1900 75 130 1100 150 170 275 20 35 9 0 9 13 1900 80 150 1100 150 175 275 20 35 Table 1 Safety clearances Power Power supply cable HO7RN F 60245 IEC 66 Fuse mm kW 400V 415V 3N A 45 5x 1 5 3x 10 6 0 5 x 1 5 3x10 8 0 5 x 2 5 3x 16 9 0 5 x 2 5 3x 16 Table 2 Cable and Fuse 2 8 Mains connection The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regula tions Sauna heater is connected with a semi permanent connection Use AO7BB F or HO7RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection cable for the sauna heate
7. helo GENUINE SAUNA amp STEAM Installation and User Manual Havanna D ELECTRIC SAUNA HEATER 400V 415V 3N 1714 450 04 1714 600 04 1714 800 04 1714 900 04 CONTACTOR BOXES 2005 3 WE 3 CONTROL PANELS 1601 12 RA 12 Digi 2 1601 13 RA 13 Digi 1 1418 2 1517 3 OT 2 PS 3 1418 2 1519 OT 2 PUi 314 SKSO 77 3 A Installation and User Manual Havanna D Contents 1 Quick 1 1 1 2 instructions for use of the sauna heater Check before taking a sauna bath Operation of the sauna heater controls 2 Information for users 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 13 Sauna room Recommended sauna room ventilation Heating the sauna Sauna heater stones If the sauna heater will not heat up Preparing for sauna heater installation Installation 2 7 1 Installation instructions 2 7 2 Heater safety distances and sensor position Mains connection Electric heating toggle Location the connection box for connection cable in the sauna room Wiring diagram Principle image when Digi 1601 12 is used as control panel Principle image when OT 2 is used as control panel 3 Spare parts for Havanna D electric sauna heater 4 ROHS Image and Table Image 1 Image 2 Image 3 Image 4 Image 5 Image 6 Image 7 Image 8 Image 9 Image 10 Image 11 Table 1 Table 2 Table 3 Recommended sauna room ventilation Heaters installation
8. id odour and dust Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from Sauna stones should be large enough measuring about 50 80 mm to allow good ventilation between the stones This extends the useful life of the heating elements Sauna stones should be piled sparsely in order to enhance ventilation between the stones Do not bend the heating elements together or against the frame Rearrange the stones regularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements Please refer to the table on page 9 Table 1 for an adequate amount of stones Any small stones in the package of stones mustn t be piled on the sauna heater The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed stones Structural clay tiles are not allowed They may cause damage to the sauna heater that will not be covered by the warranty DO NOT USE THE HEATER WITHOUT STONES Installation and User Manual Havanna D 6 2 5 Ifthe sauna heater will not heat up If the sauna heater will not heat up please check that the power is on the main fuses of the sauna heater are intact is there any error messages on the control panel In case of an error message on the control panel please refer to the control panel
9. ndung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten leisten Sie einen wichtigen Beitrag zum Schutze unserer Umwelt Dieses Produkt soll ohne Steine und Specksteinmantel an dem Sammelpunkt f r Recycling zur ckgebracht werden Bitte erfragen Sie bei der Gemeindeverwaltung die zust ndige Entsorgungsstelle 14
10. on the side of the contactor case The type plate shows the position of the switch O1 For contactor case and control panel use refer to the specific operating manuals 2 Information for users Persons with reduced physical and mental capacity sensory handicap or little experience and knowledge about how the device is operated e g children should only operate the device while supervised or according to instructions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a sauna room should be thermally well insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements in the sauna room such as decorative stone glass etc note that these elements may extend the pre heating period even though the sauna room is otherwise well insu lated see page 6 section 2 6 Preparing for sauna heater installation Installation and User Manual Havanna D 4 2 2 Recommended sauna room ventilation N l DAN Image 1 Recommended sauna room ventilation 1 Sauna room 3 Electric sauna heater 5 Exhaust flue or channel 2 Washroom 4 Exhaust valve 6 Door to the sauna room 7 A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing Inlet vent can be positioned in
11. r A multipolar e g 7 pole cable is allowed if the voltage is the same In the absence of a separate control current fuse the diameter of all cables must be the same i e in accordance with the front fuse For example in an 8 kW sauna heater the diameter of separate cables to the signal lamp and the mains control unit has to be at least 2 5 mm The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater The maximum height for the connection box is 500 mm from the floor Image 7 Location for the con nection box page 10 If the connection box is located at 500 mm distance from the heater the maximum height is 1000 mm from the floor Sauna heater insulation resistance The sauna heater heating elements may absorb moisture from air e g during storage This may cause bleeder currents The moisture will be gone after a few heating sessions Do not connect the heater power supply through a ground fault interrupter Adhere to the effective electrical safety regulation when installing the sauna heater 2 9 Electric heating toggle Electric heating toggle applies to homes with an electric heating system Sauna heater has connections marked 55 for controlling the electric heating toggle Connectors 55 and the heating elements are simultaneously live 230V The sauna heater thermostat also controls the heating toggle In other words home heating turns on once the sauna thermostat
12. s allowed per a sauna room Installation and User Manual Havanna D 2 7 1 Installation instructions 1 The wall mount is attached to the wall according to the mounting dimensions The dimensions can be found on the following page 2 Mounting the sauna heater onto the support brackets 3 Lift the heater on the support brackets so that the connection box is situated on the open side in order to allow the installation and connection of the electric cable If you wish to situate the connection box on the other side the steam guide frame of the stone compartment must be turned over The steam guide is fastened with two screws from the inside of the stone compartment see image The collar the higher edge of the steam guide must always be placed closest to the wall After mounting tighten the screws and ensure that the heater is securely fastened by lifting it carefully Image 2 Heaters installation Installation and User Manual Havanna D 8 Minimum distances for the mounting mm Drill 03 5 mm Screw 6 x 40 2kpl Screw 6 x 16 2kpl Image 3 Heaters installation 2 7 2 Heater safety distances and sensor position OLET 19 Absolute measure of 40mm IC from ceiling OLET 19 I mm 475 A A min 30 min 1100 min 1900 OLET 19 i OLET 6 1 Figure 5 Alternative installation location Figure 6 NOTE Only ceiling installation when usin
13. ten utrustning bidrar du till att skydda v r milj Produkten returneras till tervinningscentralen utan bastusten och eventuell t ljstensmantel V nligen kontakta de kommunala myndigheterna f r att ta reda p var du hittar n rmaste tervinningsplats Instructions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the instruction manual or the package refers to this The materials can be recycled according to the markings on them By reusing utilising the materials or by otherwise reusing old equipment you make an important contribution for the protection of our environment Please note that the product is returned to the recycling centre without any sauna rocks and soapstone cover Please contact the municipal administration with enquiries concerning the recycling place Hinweise zum Umweltschutz Dieses Produkt darf am Ende seiner Lebens Dauer nicht ber den normalen Haushaltsabfall Entsorgt werden sondern muss an einem Sammelpunkt f r das Recycling von elektrischen und elektronischen Ger ten abgegeben werden Das Symbol auf dem produkt der Gebrauchsanleitung oder der Verpackung weist darauf hin Die Werkstoffe sind gem ihrer Kennzeichnung wiederverwertbar Mit der Wiederverwe
14. the A zone Make sure the incoming fresh air will not interfere with i e cool down the sauna heater s thermostat near the ceiling The B zone serves as the incoming air zone if the sauna room isn t fitted with forced ventilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LO CATED AT THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna heater may emit some odour If you detect any odour while the sauna heater warms up disconnect the sauna heater briefly and air the room Then turn the sauna heater back on The sauna heater is turned on by twisting the timer knob and the temperature is adjusted from the thermostat knob You should turn the sauna heater on roughly an hour before you plan to take a sauna bath so that the stones have time to heat up properly and the air warms up evenly in the sauna room Do not put any objects on the sauna heater Do not dry clothes on the sauna heater or anywhere in its vi cinity Installation and User Manual Havanna D 2 4 Sauna heater stones Quality stones meet the following requirements Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on the stones Stones should be rinsed before use in order to avo
Download Pdf Manuals
Related Search
Related Contents
Manuale Christie Duo 769-02507 Snow Fox om Dale Tiffany TW100887 Installation Guide Guide for protecting boreholes User Manual for ARTDemoApp - Amp`ed RF Technology, Bluetooth National Instruments NI 5422 User's Manual Juillet 2010 for HPLC-ECD systems (carbohydrates) Copyright © All rights reserved.