Home
ST 3000 Smart Transmitter Specification and Model Selection Guide
Contents
1. 0 04 of URL per year Performance specifications are based on reference conditions of 25 C 77 F 10 to 55 RH and 316L SS diaphragm Transmitter URL limit or maximum process connection rating whichever is lower 34 ST 03 70 Page 6 Performance Under Rated Conditions General for all Models Parameter Description Output two wire Analog 4 to 20 mA or digital communications DE mode Options available for FOUNDATION Fieldbus and HART protocol Supply Voltage Effect 0 005 span per volt Damping Time Constant Adjustable from 0 to 32 seconds digital damping EMC Classification CE Conformity Europe Lightning Protection Option Code LP Group 1 Class A ISM Equipment EN 55011 emissions Industrial Equipment EN 50082 2 immunity 89 336 EEC Electromagnetic Compatibility EMC Directive 10 microamps max 42 4 VDC 93 C 10 20 u sec 5 000 Amps 50 strikes 10 000 Amps 20 strikes 10 1000 u sec 250 Amps 1000 strikes 500 Amps 400 strikes Leakage Current Impulse Rating rise decay Physical and Approval Bodies Parameter Description Process Interface See Model Selection Guide for Material Options for desired process connection Diaphragm Materials wetted 316L Stainless Steel Gasket Ring Materials wetted 316L Stainless Steel Mounting Flange non wetted 316 Stainless Steel Fill Fluid Sili
2. Abu Dhabi U A E In Asia Honeywell Asia Pacific Inc Honeywell Building 17 Changi Business Park Central 1 Singapore 486073 Republic of Singapore In the Pacific Honeywell Pty Ltd 5 Thomas Holt Drive North Ryde NSW Australia 2113 61 2 9353 7000 In Japan Honeywell K K 14 6 Shibaura 1 chrome Minato ku Tokyo Japan 105 0023 Or visit Honeywell on the World Wide Web at http www honeywell com 34 ST 03 70 Page 11 Model Selection Guide 34 ST 16 47 Instructions Select the desired Key Number The arrow to the right marks the selection available Make one selection from each Table and Il using the column below the proper arrow Select as many Table III options as desired if no options or approvals are desired specify 9X An approval code MUST be selected A denotes unrestricted availability A letter denotes restricted availability Restrictions follow Table IV Key Number l Ill Optional ssc ure am oe es me ama eos KEY NUMBER Selection Availablilty 0 0 9 to 0 500 psig 0 0 063 to 0 35 barg STG14T v 0 0 9 to 0 500 psig 0 0 063 to 0 35 barg Flange Mount STF14T Vv The STG amp STF14T replaces the STG amp STF15T models TABLE METER BODY Barrier Diaphragm Process Heads ete eee Threaded 316L SS 316 E Je Barrier Diaphragm Lower wetted ZARR Silicone see Process Head No ae TABLE II FLANGE ASSEMBLY Selection No Selection No Selection 1 2 ANSI Cla
3. Without Meter Without Meter 3 74 With With 3 135 Meter Met pe eae lt q gt Z gt eter 0 12 ai 5 32 Plug 48 5 F Ba ay R NPT gt OR i ee Optional Adapter i _ for M20 or 3 4 A SE ie NPT fC o Optional IJ a Analog m Meter on S 4 carey ae oD Terminal Optional Block side Local Smart Meter on Optional 151 162 Electronics External 5 95 6 38 ic coun Rotational Lock es pe 2 Tri Clamp gt Sanitary connection lt 63 1 2 48 Figure 5 Typical mounting dimensions for flush sanitary seal connection models for reference Reference Dimensions millimeters inches Removal Clearance for all Caps Optional Analog Meter on Terminal Block Side Rotational lt gt lt 53 1 34 ST 03 70 Page 9 65 1 45 7 82 9 1 80 3 26 With Meter 2 09 Without Meter gt lt a 2 56 Without Meter Optional Adapter for M20 or 3 4 NPT Customer Supplied Flange and Hardware Local Smart Meter on Electronics Side O Optional External Ground a i Flange Flange Description Thickness t Bolt Raised Face Circle B Dia Raised Face B Diameter Bolt Circle 60 3 34 9 2 38 1 38 Studs are threaded and welded in place Figure 6 Typical mounting dimensions
4. for small flange connection models for reference 34 ST 03 70 Page 10 Options Indicating Meter ME and SM Options Two integral meter options are available An analog meter option ME is available with a 0 to 100 linear scale The Smart Meter option SM provides an LCD display for both analog and digital output and can be configured to display pressure in pre selected engineering units Lightning Protection Option LP A terminal block is available with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes HART Protocol Compatibility Option HC An optional electronics module is available for the ST 3000 that provides HART Protocol compatibility Transmitters with the HART Option are compatible with the AMS System Contact your AMS Supplier if an upgrade is required Transmitter Configuration Option TC The factory can configure the transmitter linear square root extraction damping time LRV URV and mode analog digital and enter an ID tag of up to eight characters and scratchpad information as specified Lifetime Warranty Option WL Extends limited 1 year warranty policy to 15 years for ST 3000 S100 pressure transmitters See Honeywell Terms and Conditions Indicator Configuration Option Cl Provides custom configuration of Smart Meters Tagging Option TG Up to 30 characters can be added on the stainless steel nameplate mounted on the tr
5. O OOK OO o o X o O 34 ST 03 70 Page 13 Model Selection Guide cont Availability STF14T STG14T Approval Body Approval Type Location or Classification No hazardous location approvals 9X ele Explosion Proof Class I Div 1 Groups A B C D Factory Dust Ignition Proof Class Il Ill Div 1 Soups E F G Mutual intrinsically Safe Class T Tl Tl Div T Groups A B T D EFG Class Div 1 ros B C D Intrinsically Safe Exia iC 14 Non Sparking ExnliCT6 O O Intrinsically Safe oll 1 G EEx ia IIC 14 T5 16 iil o EE Flameproof Zone 1 Ell 2 G EExd IIC T5 T6 Non Sparking Ell 3 G EEx nA IIC T6 Zone 2 Honeywell Enclosure IP 66 67 3N See ATEX installation requirements in the ST 3000 User s Manual 97 23 EC Pressure Equipment Directive PED The ST 3000 pressure transmitters listed in this Model Selection Guide are in conformity with the essential requirements of the PED A formal statement from TUV Industry Service Group of T V America Inc a division of T V S ddeutschland a Notified Body regarding the Pressure Equipment Directive is available upon request TABLE IV Factory Identification XXXX RESTRICTIONS Restriction Available Ony Win Not Availabre wih Letter Tabie Selection Table Selection Ca aoaBodgyPensng O O O O O OOOO e f m f select ony one option fom his group e oa o 28 m Oe A 34 ST 03 70 Page 14 This
6. Page 2 Description The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates over a standard two wire system The measuring means is a piezoresistive sensor which actually contains three sensors in one It contains a differential pressure sensor a temperature sensor and a static pressure sensor Microprocessor based electronics provide higher span turndown ratio improved temperature and pressure compensation and improved accu racy The transmitter s meter body and electronics housing resist shock vibra tion corrosion and moisture The electronics housing contains a com partment for the single board electronics which is isolated from an inte gral junction box The single board electronics is replaceable and inter changeable with any other ST 3000 Series 100 or Series 900 model transmitter Like other Honeywell transmitters the ST 3000 features two way com munication between the operator and the transmitter through our Smart Field Configurator SFC You can connect the SFC anywhere that you can access the transmitter signal lines The SCT 3000 Smartline Configuration Toolkit provides an easy way to configure instruments using a personal computer The toolkit enables configuration of devices before shipping or installation The SCT 3000 can operate in the offline mode to configure an unlimited number of de vices The database can then be loaded downline during commissioning F
7. Page Intentionally Blank ST 3000 is a registered trademark of Honeywell International Inc HART is a trademark of the Hart Communication Foundation FOUNDATION is a trademark of the Fieldbus Foundation Honeywell Industrial Measurement and Control Honeywell International Inc 16404 North Black Canyon Highway Phoenix Arizona 85053 Honeywell International Inc
8. ST 3000 Smart Transmitter Series 100 High Temperature GP Models 0 500 psig 0 35 barg STG14T STF14T Introduction In 1983 Honeywell introduced the first Smart Pressure Transmitter the ST 3000 In 1989 Honeywell launched the first all digital bi directional protocol for smart field devices Today Honey well transmitters demonstrate proven reliability in hundreds on installations in a wide variety of industries and applica tions For applications requiring direct connection to processes requiring small flange small sanitary connec tions or 1 2 NPT Honeywell offers the STG14T transmitter Applications in clude gauge pressure for reaction ves sels in the chemical industry as well as level applications in both the chemical and hydrocarbon processing industries with a relatively high process tempera ture of 302F 150C Applications for the food and pharmaceutical industries typically use sanitary connections and M 20 fill fluid All ST 3000 transmitters can provide a 4 20 mA output Honeywell Digitally Enhanced DE output HART output or FOUNDATION Fieldbus output When digitally integrated with Honey well s Process Knowledge System EXPERION PKS ST 3000 instru ments provide a more accurate proc ess variable as well as advanced diag nostics Honeywell s high performance ST 3000 100 transmitters lead the industry in e Accuracy e Stability e Reliability e Rangeability e Warrant
9. ansmitter s electronics housing at no extra cost Note that a separate nameplate on the meter body contains the serial number and body related data A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available The number of characters for tagging includes spaces Custom Calibration and ID in Memory Option CC The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory FOUNDATION Fieldbus Option FF Equips transmitter with FF protocol for use in 31 25 kbit s FF networks See document 34 ST 03 72 for additional information on ST 3000 Fieldbus transmitters Specifications are subject to change without notice Ordering Information Contact your nearest Honeywell sales office or In the U S Honeywell Industrial Automation amp Control 16404 North Black Canyon Hwy Phoenix AZ 85053 1 800 288 7491 In Canada The Honeywell Centre 155 Gordon Baker Rd North York Ontario M2H 3N7 1 800 461 0013 In Latin America Honeywell Inc 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 954 845 2600 In Europe and Africa Honeywell S A Avenue du Bourget 1 1140 Brussels Belgium In Eastern Europe Honeywell Praha s r o Budejovicka 1 140 21 Prague 4 Czech Republic In the Middle East Honeywell Middle East Ltd Khalifa Street Sheikh Faisal Building
10. ave the CE mark or the manufacturer has the free choice of a module when the CE mark is required for pressures gt 200 bar 2 900 psig NOTE Pressure transmitters that are part of safety equipment for the protection of piping systems or vessel s from exceeding allowable pressure limits equipment with safety functions in accordance with Pressure Equipment Directive 97 23 EC article 1 2 1 3 require separate examination Pressure Connection Reference Diniencion _ millimeters ererence ensions inches pele oA EAEE 65 1 PERA Removal Clearance 45 7 82 9 2 09 2 56 94 9 for All Caps 41 80 3 26 Without Meter Without Meter 3 74 3 135 ne Ha Meter Meter 0 12 zg 5 32 Plug pa L De 48 5 TI as 1 91 1 2 NPT gt OR EWEN ay R ra Adapter _ for M20 or 3 4 _ NPT loa ir Optional Analog i Meter L Eg a ae Optional 5 186 7 197 7 External 7 35 7 78 Ground Rotational Lock 112 NPT Figure 4 Typical mounting dimensions for 1 2 inch NPT connection models for reference 34 ST 03 70 Page 8 Ref Di _ millimeters ererence Dimensions inches aaa 93 1 pig 85 1 _ypig Removal Clearance 457 82 9 _ 2 09 2 56 94 9 for All Caps 1 80 3 26
11. cone DC 200 or Neobee M20 Electronic Housing Epoxy Polyester hybrid paint Low copper aluminum alloy Meets NEMA type 4X watertight and designed to meet NEMA 7 explosion proof Process Connections Process Head 1 2 inch NPT Sanitary 2 Sanitary Tri Clamp Flange 1 2 1 1 1 2 and 2 150 or 300 ANSI flange Wiring Accepts up to 16 AWG 1 5 mm diameter Mounting 1 2 inch NPT sanitary seal or flange mount connection Dimensions See Figures 4 to 6 Net Weight 7 pounds 3 2 Kg to 15 pounds 7 Kg Table continued on next page gt 34 ST 03 70 Page 7 Physical and Approval Bodies continued Parameter Description Approval Bodies Hazardous Areas Approved as explosion proof and intrinsically safe for use in Class Division 1 Groups A B C D locations and nonincendive for Class Division 2 Groups A B C D locations Approved EEx ia IIC T4 T5 T6 and EEx d IIC T5 T6 per ATEX standards See attached Model Selection Guide for options 97 23 EC Pressure Equipment Directive The ST 3000 pressure transmitters listed in this Specification have no pressurized internal volume or have a pressurized internal volume rated less than 1 000 bar 14 500 psig and or have a maximum volume of less than 0 1 liter Therefore these transmitters are either not subject to the essential requirements of the directive 97 23 EC PED Annex 1 and shall not h
12. eatures Choice of linear or square root output conformity is a simple configuration selec tion Direct digital integration with Experion PKS and other con trol systems provides local measurement accuracy to the system level without adding typical A D and D A converter inaccuracies Unique piezoresistive sensor automatically compensates input for temperature and static pressure Added smart features include configuring lower and upper range val ues simulating accurate ana log output and selecting pre programmed engineering units for display Smart transmitter capabilities with local or remote interfac ing means significant man power efficiency improve ments in commissioning start up and ongoing mainte nance functions Tank Level Measurement Application Pressure transmitters are commonly used to measure the level in an open or non pressurized tank See Figure 2 The level is directly proportional to the DP H1 measurement by the relationship Level H1 x SGp Where SGp specific gravity of process fluid Figure 2 Tank Level Measurement Small Flange shown Maximum Level Minimum Level 34 ST 03 70 Page 3 34 ST 03 70 Page 4 Operating Conditions All Models Specifications Parameter Silicone Fill Fluid Ambient Temperature Process Interface Temp Neobee Fill Fluid Ambient Temperature Process Interface Temp Humidity RH Over
13. o support communications Loop resistance equals barrier resistance plus wire resistance plus receiver resistance Also 45 volt operation is permitted if not an intrinsically safe installation 21012 1440 1200 aop 800 Resistance ohms 650 450 Figure 3 Supply Voltage and 0 10 8 16 28 20 63 25 28 3 37 0 42 4 Loop Resistance Chart Operating Voltage Vdc 34 ST 03 70 Page 5 Ambient Temperature De rating Silicone Fill Fluid Neobee Fill Fluid Process temperatures above 125 C 257 F require Process temperatures above 85 C 185 F require de rating the ambient limit as follows de rating the ambient limit as follows Process Temperature Ambient Temperature Process Temperature Ambient Temperature Limit Limit 150 C 302 F 50 C 122 F 110 C 230 F 50 C 122 F 140 C 284 F 60 C 140 F 100 C 212 F 60 C 140 F 125 C 257 F 85 C 185 F 85 C 185 F 75 C 167 F Performance Under Rated Conditions Models STG14T and STF14T 0 500 psig 0 35 barg Parameter Description Upper Range Limit psig barg 500 psig 35 barg Minimum Span psig barg 0 9 psig 0 063 barg Turndown Ratio 550 1 Zero Elevation and Suppression No limit except minimum span from absolute zero to 100 of URL Specifications valid over this range Accuracy Reference Includes In Analog Mode 0 0875 of calibrated span or upper range value URV combined effec
14. pressure Sanitary Threaded psi bar Flanged ANSI Class 150 psi bar ANSI Class 300 psi bar Vacuum Region Minimum Pressure mmHg absolute inH20 absolute Supply Voltage Current and Load Resistance Reference Rated Condition Operative Limits Transportation and Condition Storage oC oF oF oC oF oC oF 25 1 7742 40 to 85 40 to 185 40 to 93 40 to 200 55to125 67 to 257 25 1 7742 40 to 150 40 to 302 40to 150 40 to 302 NA NA 25 1 7742 15 to 75 5 to 167 15 to 75 5 to 167 15 to 75 5 to 167 25 1 7742 15 to 110 5 to 230 15 to 110 5 to 230 NA NA 10 to 55 0 to 100 0 to 100 0 to 100 0 750 750 0 52 52 316 SS 316 SS 0 275 215 0 19 15 0 720 560 0 50 39 atmospheric 300 t 2 short term tt atmospheric 150 1 short term tt Voltage Range Current Range 3 8 to 21 8 mA 10 8 to 42 4 Vdc at terminals Load Resistance 0 to 1440 ohms as shown in Figure 3 Sanitary pressure rating depends on the type of clamp Single toggle type rated to 150 psi 10 bar Flange rating versus temperature is per ANSI B16 5 Value shown is for reference temperature Flange rating versus temperature is per ANSI B16 5 Value shown is for operative limit temperature t Limit is 600 mmHg absolute 321 inH2O absolute for Neobee fill tt Short term equals 2 hours at 70 C 158 F A Operating Area NOTE A minimum of 250 Ohms of loop resistance is necessary t
15. ss 150 1 ANSI Class 150 1 ANSI Class 300 1 1 2 ANSI Class 150 1 1 2 ANSI Class 300 2 ANSI Class 150 2 ANSI Class 300 No Selecion fT Drain 34 ST 03 70 Page 12 Model Selection Guide cont Availability STF14T STG14T l TABLE III OPTIONS Selection FOUNDATION Fieldbus Communications HART Protocol compatible electronics Analog Meter 0 100 Even 0 10 Smart Meter Customer Configuration of Smart Meter Local Zero Local Zero and Span Lightning Protection Custom Calibration and I D in Memory Transmitter Configuration Write Protection 316 SS NACE Bolts and 304 SS NACE Retaining Ring for Head and 316 SS NACE Bolts for Adapter Stainless Steel Customer Tag 4 lines 28 characters per line customer supplied information Stainless Steel Customer Tag blank Viton Process Head Gasket teflon is standard 316 ST ST Electronics Housing with M20 Conduit Connections M20 316 SS Conduit Adapter 3 4 NPT 316 SS Conduit Adapter Stainless Steel Housing with M20 to 1 2 NPT 316 SS Conduit Adapter use for FM and CSA Approvals Calibration Test Report amp Certificate of Conformance F3399 Certificate of Conformance F3391 Certificate of Origin F0195 Attestation if Amiens built FMEDA SIL Certificate NACE Certificate F0198 Additional Warranty 1 year Additional Warranty 2 years Additional Warranty 3 years Additional Warranty 4 years Lifetime Warranty 15 years a e e ee 3B xK O Qa 4 43 xk O
16. ts of linearity whichever is greater hysteresis and repeatability For URV below reference point 20 psi accuracy equals 1 4 bar Jor 0 025 0 0625 ganar in span In Digital Mode 0 075 of calibrated span or upper range value URV whichever is greater For URV below reference point 20 psi accuracy equals Accuracy includes residual error after 410 025 0 0625 Geena averaging successive readings span psi e For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications _20 psi_ 14bar g p 0 0125 0 0625 span psi Jor 0 0125 0 0625 spanbar in span Zero Temperature Effect per 28 C In Analog Mode 0 0625 of calibrated span 50 F For URV below reference point 50 psi effect equals 50 psi 3 5 bar 0 0125 0 05 zarpa Jor 0 0125 0 05 antar in span In Digital Mode 0 05 of calibrated span For URV below reference point 50 psi effect equals 50 psi 3 5 bar 0 05 es psi or 0 05 Span bar bar in span Combined Zero and Span In Analog Mode 0 10 of calibrated span Temperature Effect per 28 C 50 F For URV below reference point 50 psi effect equals 50 psi 3 5 bar 0 05 0 05 ara Jor 0 05 0 05 ater Jin span In Digital Mode 0 075 of calibrated span For URV below reference point 50 psi effect equals 50 psi 3 5 bar 0 025 0 05 oaa Jor 0 025 0 05 oa in span Stability
17. y Includes Lifetime Tranmsitters e Accuracy 0 0375 e Stability 0 01 per year e Reliability 470 years MTBF e Rangeability 400 to 1 e Lifetime Warranty 15 years Honeywell 34 ST 03 70 10 2002 Specification and Model Selection Guide Figure 1 Series 100 High Temperature GP Transmitters feature proven pie zoresistive sensor technology The devices provide comprehensive self diagnostics to help users maintain high uptime meet regulatory requirements and attain high quality standards S100 transmitters are ideal for critical applications such as custody transfer of natural gas and energy and material bal ances where accuracy and stability are of the utmost importance Our commitment to Honeywell field instruments is based on seam less integration with our Honeywell system and the enhanced fault detection that the Honeywell DE protocol offers Honeywell instru ments also offer us a better way of ensuring database integrity over simple analog instruments In addition Honeywell s high quality sup port has enabled us to better implement solutions to some of our more difficult problems We have used Honeywell differential pressure smart transmitters for the past eight years Based on their accuracy and low failure rates we are now targeting critical flow applications that require the robustness that these transmitters bring DCS Systems Engineer International Integrated Oil Company 34 ST 03 70
Download Pdf Manuals