1. erate the unit at high fan speed The compressor will not be switched on in this function 3 Low Cool Speed Turn the control knob to the COOL position smaller fan to INSTALLATION operate the unit in low cool speed Unit Setup High Cool Speed Turn the control knob to the COOL position larger fan to operate the unit in high cool speed Fig 1 Note Fig 1 When the unit operates in cooling mode the POWER light will be switched on When the water tank is full the FULL light will be switched on 1 Lift unit and remove the exhaust hose from the base 2 Fit hot air exhaust hose to the unit as shown on diagram below 3 Install exhaust hose be rotating it clockwise onto the hot air exhaust attachment Fig 2 Ensure it is fully inserted before use 4 To remove rotate in an anti clockwise direction Locating the unit Install the portable air conditioner in a flat location with adequate space to ensure the air inlets and outlets will not be blocked Keep a minimum clearance of 50cm from walls and other objects Position the unit to allow the exhaust hose to reach a suitable window as shown Avoid sharp bends or kinks in the exhaust hose The optional adjustable window slider is included to ensure the exhaust hose is held in place in the window and prevents expelled hot air re entering the room The appliance should not be used in damp areas such as a laundry or ba
2. ewt MODEL EWTC9 INSTRUCTION MANUAL PORTABLE AIR CONDITIONER IMPORTANT INFORMATION Carefully read this instruction manual before you install or use your portable air conditioner Please retain this manual for product warranty and for future reference CAUTION 1 Make sure the inlet and outlet vents are never blocked 2 Ensure the appliance is on a stable even surface when operating to avoid water leakage 3 Do not operate this unit in an explosive or corrosive atmosphere 4 When switched to cooling only operate this unit in ambient temperatures between 17 C and 43 C 5 Clean the air filter frequently to ensure efficient operation 6 To prevent compressor damage when the unit has been operating and is turned off please wait at least 3 minutes before restarting 7 This unit needs to be plugged into a 220 240V 50Hz AC 10 Amp power outlet 8 Do not use any extension cords with this unit 9 This unit is for indoor operation only 10 Open the adjustable air vent and extend the exhaust pipe and drain pipe if fitted to the closest window before using 11 Only ever have a professional technician manufacturer or service agent replace a damaged power cord 12 The batteries from the remote control must be removed and disposed of safely before the appliance is scrapped 13 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lac
3. k of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 14 Children should be supervised to ensure that they do not play with the appliance Important The air conditioner must always be stored and transported upright In case of doubt we suggest you wait for at least 24 hours before operation Please keep unit upright at all times PACKAGE CONTENTS Portable air conditioner User manual Extendable window kit PARTS 1 Control panel ae Pej Cool air outlet Exhaust hose connector eT Exhaust hose i Hot air inlet Lower drain hose HIO pr pr w a Hot air exhaust hose attachment 6 8 Hot air outlet 1S 9 Cool air outlet 10 Upper drain hose CONTROLS AND DISPLAY COOL FAN Sis sig COOL STARTING THE UNIT 1 Turn the control knob to the POWER OFF position 2 Plug the unit into a standard 10amp power supply 3 Turn the control knob to the COOL position The POWER light will turn on while the unit is in operation SWITCHING THE UNIT OFF Turn the control knob to the POWER OFF position FUNCTION Low Fan Speed Turn the control knob to the FAN position smaller fan to operate the unit at low fan speed The compressor will not be switched on in this function High Fan Speed Turn the control knob to the FAN position larger fan to op
4. llection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water polluting the food chain and damaging health and well being 10 SPECIFICATION Power Consumption EN14511 Dimensions mm 11
5. s are Remove the blockage blocked The room temperature is Lower set temperature below the set temperature The air conditioner is not Place the air conditioner on an even solid level surface The air conditioner is noisy The Wait 30 minutes until the temperature has compressor The overheat protection is decreased then restart the air conditioner does not activated Note Compressor operation begins 3 work minutes after the unit is switched on The distance between the Move closer to the air conditioner Aim the The remote remote control and the air Soniral condiuoner lt io lar remote control directly at the control panel does not function The batteries are flat Replace the batteries If you have any issues with your unit please contact Glen Dimplex on 1300 556 816 for your nearest service agent Proof of purchase is required at the time of service WARRANTY The warranty period is 24 months from the date of purchase Glen Dimplex Australia Pty Ltd Glen Dimplex New Zealand Ltd Unit 1 21 Lionel Road 38 Harris Road East Tamaki Mount Waverley VIC 3149 Manukau Auckland 2013 Australia New Zealand Ph 1300 556 816 Ph 09 274 8265 Fax 1800 058 900 Fax 09 274 8472 Web www dimplex com au Web www dimplex co nz DISPOSAL Do not dispose of electrical appliances as unsorted municipal waste Use separate collection facilities e Contact your local government for information regarding the co
6. throom Do not place the unit where it will be in direct sunlight as it may overheat and turn off ADJUSTABLE WINDOW SLIDER KIT The adjustable window slider kit is installed as shown below Window slider kit min 55cm max 100cm Window slider kit min 55cm max 100cm WATER DRAIN When the air conditioner is used excess water condensation may be produced that will fill the water tank This water is captured by an internal container When this is full the unit will stop working and the FULL indicator will illuminate This means the unit will need to be drained as follows 1 Switch off and unplug the unit 2 Move the unit to a suitable location to drain the water Consider placing a small tray beside the outlet pipe to catch the drained water 3 Remove the drain plus as per the image below Fig 2 4 Slightly tilt the unit to the rear to drain the water 5 Replace the drain plug Ensure the drain plug is fully fitted before use Connect the exhaust hose to the window kit before the unit is switched back on MAINTENANCE WARNING ALWAYS UNPLUG THE UNIT BEFORE MOVING OR CLEANING CLEANING Air filters The air filters are located on the left and right side of the unit To remove the air filters please follows the arrow directions below by pulling out the filters in an upward direction Clean only with warm soapy water Cabinet As with filters clean only with warm soapy
7. water CARE OF THE UNIT 1 Only plug the unit into a suitable 220 240V 50Hz AC 10 AMP power supply 2 Hold the plug when unplugging the unit never pull on the cord 3 Do not place the unit in direct sunlight This can fade the plastic case 4 Do not operate the unit in a confined space 5 Do not place objects on top of the unit This blocks the air outlet 6 Do not place the unit where the air inlets or outlets may be blocked by curtains or furniture 7 Keep the filters clean OVERHEAT PROTECTION This unit is fitted with an overheat prevention device If the unit overheats it will TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself Unauthorized repairs may result in automatically turn off The unit can be restarted after 30 minutes the loss of warranty and can endanger the user and their property Connect to a functioning power supply No power supply socket and switch on The air conditioner does not FULL indicator is shown indicating the internal water Empty the internal water container Refer to WATER DRAIN container is full operate The start timer function is Press the POWER button to deactivate the active TIMER function The air conditioner is in direct de thevcuaing sunlight THEA Windows or doors are open Close windows and doors conditioner COE tet The filters are dirty Clean the filters seem to operate efficiently The air inlets or outlet

Download Pdf Manuals

image

Related Search

Related Contents

Giardia Control Kit  Brodit ProClip 513514  Cables Direct 15.0m LC-ST 62.5/125 MMD OM1  Emerson NetSure 802 DC Power System Application Guide  Concurrence, mode d`emploi  Télécharger PDF - Paul Forrer AG  Triarch 31610/1 User's Manual  Untitled - Perfuradores.com  Montageanweisung WWP L 6 AD  CoMo AV Instruction Manual  