1. On Off switch on the DB inverter box to the On position e Switch off the breaker in the main DB to the circuits that will be supplied by the inverter e After 2 seconds you should hear the inverter working Verify that the circuits have power on them If not verify all your wiring e Replace the covers to both DB boards e Place a label on the main DB board circuit breakers with a label stating that the respective breakers are going to the Inverter DB e Place a label on the Inverter DB facia indicating the respective circuits that are being supplied by the inverter e Place a label indicating the method to isolate the circuits so that any future electrician will be aware of the modifications made on the DB boards e The system is now ready for full operation To isolate the loads from the DB boards you must switch the respective circuit breakers off on both DB s and place the On Off switch of the Inverter DB into the off position so that the inverter is not powered by the battery Specifications Inverter power 500Watt or 1000Watt model dependant Inverter output voltage 200V to 250V dependant on battery voltage Inverter wave output Modified sine or Pure sine wave model dependant Inverter load 100 overload for 1 second Unit physical size W 223mm D 286mm H 124mm Weight 500W model 4Kg 1000W model 5Kg Packed size 235mm X 300mm X 130mm Packed weight 500W model 4 5Kg 1000W model 5 5Kg Bat
2. and on the other end join to the main DB box earth bar Next connect the Red wire of the Norsk cable to the Circuit breaker bottom output terminal Join the other Red wire side to the cable removed from the main DB circuit breaker at an earlier step Use a glass end cap to make the connection safe 2 Circuit breaker DB Inverter Unit Do the same to the next circuit breaker circuit and connecting to the number L1 terminal of the changeover PCB Take the wire from the 2 circuit breaker bottom output terminal and join to the second circuit in the main DB box Connect the battery as per the next step Connecting the Battery The battery is the energy source which the inverter uses to drive your load Any problems with your battery will have a direct influence on the capability of the inverter to supply your load When using the battery for the first time charge the battery at least for 24 hours to get the full output capacity of the battery BEFORE CONNECTING OR REMOVING THE BATTERY ENSURE THAT THE PANEL ON OFF SWITCH IS IN THE Off POSITION THE MAINS SUPPLY FROM THE ORIGINAL DB BOARD IS IN THE OFF POSITION Failure to do this may cause damage to the DB Grid Charged Inverter or to your load This action will also void all warranties REVERSE CONNECTION OF THE BATTERY WILL ALSO VOID ALL WARRANTIES BEFORE MAKING ANY CONNECTIONS MAKE SURE THAT YOU ARE CONNECTING THE CORRECT COLOUR WIRE TO THE BATTERY The
3. symbol or with a BLACK washer or other marking such as Neg Now take the BLACK wire and locate the end ring and attach it to the battery terminal Tighten the screw or bolt well Tug on the cable and ensure that the ring does not move If it does move then retighten the screw bolt DO NOT OVETIGHTEN or you may strip the thread either in the battery or strip the bolt Next locate the Positive terminal on the battery This is usually marked with a symbol or with a RED washer or other marking such as Pos Now take the RED wire and locate the end ring and attach it to the battery terminal Tighten the screw or bolt well Tug on the cable and ensure that the ring does not move If it does move then retighten the screw bolt DO NOT OVETIGHTEN or you may strip the thread either in the battery or strip the bolt In Line Battery Connector In the case the inline connector has not been connected to a battery then follow these instructions Check the battery and locate the Negative terminal on the battery This is usually marked with a symbol or with a BLACK washer or other marking such as Neg Now take the BLACK wire and locate the end ring and attach it to the battery terminal Tighten the screw or bolt well Tug on the cable and ensure that the ring does not move If it does move then retighten the screw bolt DO NOT OVETIGHTEN or you may strip the thread either in the battery or strip the bolt N
4. following convention is used in this manual and with the DB Grid Charge Inverter RED Positive BLACK Negative Depending on which model you have there are two ways that the unit connects to the battery either directly from the cables from the unit to the battery or via an inline battery connector If the battery was supplied by the unit representative chances are that the battery will have already been connected to the inline connector correctly and you simply have to mate the connectors and push them in until a solid click is felt and heard The polarity of the battery would have been confirmed by your supplier In the case that you have not purchased the battery directly from your supplier then you will have to connect the battery to the DB Grid Charge Inverter Before commencing ensure you have the correct tools to tighten the cables to the battery terminals To avoid damage fire or dangerous usage must you under no circumstances use a different capacity of battery for what the unit has been manufactured for Battery Charge table Maximum Battery Minimum Charge Capacity Recommended Current Amp Hour solar panel size 1 5A 20Amp 35W 3A 30Amp 75W 4A 45Amp 100W 6A 65Amp 150W 7 5A 80Amp 180W 10A 100Amp 250W 12 5A 125Amp 300W 15A 150Amp 350W Cables with ring connectors Check the battery and locate the Negative terminal on the battery This is usually marked with a
5. DB Grid Charged Inverter PR301 Renewable energy series Light and power from batteries By Microsolve C C User Manual Thank you for purchasing this state of the art product This product has been designed to provide years of trouble free service Introduction This unit serves as an alternative electrical supply DB to any existing grid supplied home to provide limited power via an inverter running off batteries The main features is the simplicity of operation to the user Depending on the control switch position the system can supply power upon a power failure or load shedding situation automatically or can be under the control of the user via a panel mounted control switch The user simply ensures that any equipment powered by the wall mounted DB inverter is what is required and any nonessential appliance is switched off to preserve energy in the battery for the limited powered appliances The only understanding the user must have is that there is a limited amount of energy stored in the battery and it will power whatever is connected to the battery for a fixed period of time The amount of time that the inverter runs will be directly linked to battery size and load consumption that is the number of appliances powered by the inverter The higher the load consumption the less time the battery will be able to maintain power to the load via the inverter The unit has its own DIN rail mounted circuit breakers not only to offer overloa
6. d protection to the equipment but to also enable safety to any maintenance being done on the circuits connected to the DB This DB unit is to only be installed by qualified electricians who understand the operation of alternative power supplies and must be installed under the respective local electrical regulations who must also provide the necessary certificates of conformity Sine Wave Output Depending on the model you have purchased it can either be a modified Sine Wave or a Pure Sine Wave The unit converts the 12V DC from the battery to 230V AC using power electronics The AC can be used to power up a number of mains equipment It is important that you do not overload the inverter In the case that the inverter is overloaded it will shut down and will require you to switch the unit off remove the loads and switch on again Reconnect the loads one a time to see which load is over loading the inverter If the inverter you have is too small for your application then you may have to purchase an inverter which can handle a higher load Speak to your supplier to see what other solutions that they may have for your application Modified Sine Wave Suitable for most loads such as TVs P C s decoders LED and CFL lamps cell phone chargers Pure Sine Wave Suitable for devices with electric motors fans micro waves gate controllers audio equipment TVs P C s decoders LED and CFL lamps cell phone chargers Operation The inv
7. erter output is controlled by the On Off switch at the base of the DB unit When the mains is available there is power through the switch over control through the DIN rail mounted circuit breakers and directly to the loads connected to the DB unit irrespective if the switch is in the On or Off position When the mains fails and the switch is in the Off position the inverter is disconnected and there is no power to the load When the mains returns the internal switch will immediately pass the mains to the loads again In the case that the switch is in the On position while mains is available there is power through the switch over control through the DIN rail mounted circuit breakers and directly to the loads connected to the DB unit When there is a mains failure the internal relay switches over and the inverter starts and approximately 2 seconds later there will be power through the changeover switch through the panel mounted circuit breakers and the load is powered by the inverter When the mains returns the internal relay immediately transfers the mains to the loads and switches the inverter off This ensures that the inverter only works when the user wishes to have battery backup and preserves the battery should there be a mains failure during a time the user is not making use of the battery backup thereby preserving the battery for when it is required by the user When the switch is in the Off position the inverter does n
8. ext locate the Positive terminal on the battery This is usually marked with a symbol or with a RED washer or other marking such as Pos Now take the RED wire and locate the end ring and attach it to the battery terminal Tighten the screw or bolt well Tug on the cable and ensure that the ring does not move If it does move then retighten the screw bolt DO NOT OVETIGHTEN or you may strip the thread either in the battery or strip the bolt Connect to the unit inline connector by mating with the battery side connector and push in until you feel and hear a click To disconnect the in line connector simply pull hard on each connector and they will separate The advantage of the inline connector is that you can change batteries very quickly without tools or without having to worry about the polarity being correct ALWAYS remember to switch the DB Inverter unit off and to disconnect the main DB circuit breakers off when disconnecting or connecting the battery The amount of time that the inverter runs will be directly linked to battery size and load consumption The higher the load consumption the less time the battery will be able to maintain power to the load via the inverter Electronics Charger and Controller A PWM based 3 stage charger ensures the battery is fully charged For best results match the battery to the internal charger Adding more batteries will take the charger longer to charge all the batteries in so
9. me cases if the internal charger is too small then it may never charge the batteries properly thereby affecting the amount of inverter running time Always order and match the battery to the DB Inverter charger There is an internal circuit which monitors the battery voltage and when it drops below 10 5V will disconnect until the power is restored and the battery is recharged On new installations in which there is no mains available at the time of installation and the user wishes to use the inverter locate the red reset button on the bottom side of the DB inverter unit press for a second or two to enable the electronics to power up and run the inverter This is not s Reset switch for when the battery has been disconnected due to use and is now below the 10 5V threshold Continually over riding this mode will damage the battery permanently When the battery is discharged and is in this situation ensure that the battery is charged as soon as it is possible to ensure the battery recovers from this deep discharge Periods longer than 12 to 24 hours will begin the damage to the battery chemistry Switch On the system Recheck the wiring to ensure that there are no shorts open circuits or errors Switch on the main DB circuit breaker Next switch on the 2 isolated circuits via the circuit breakers in both DB boxes Test to see that mains is getting to the 2 circuits that were modified If not recheck your wiring e Place the
10. nverter DB and the battery connections It is better to have longer mains wires than to extend the battery wires The reason for this is the high currents on the battery side will require the use of very thick copper cables to prevent volt drops across the cables and reduce the efficiency of the inverters Remove the lid of the inverter DB box by loosening the 4 large plastic screws in each corner Mounting of the box to the wall will make use of the 4 corner holes in which to use a maximum of MS screws or bolts to mount to the wall Once the box is bolted on the wall open the main DB box and trace out the 1 or 2 circuits which will be supplied by the inverter Switch off the main switch on the DB and always observe safety when working around the DB boxes Remove the 1 or 2 wires from the original circuit breakers Using Norsk 6Amp cable will make the installation easier and safer Find the earth bar on the main DB box connect the Norsk cable earth wire to the this earth terminal and route the Norsk cable to the DB inverter box Place the first cable Red wire cable from the existing circuit breaker and connect to the DB Invertor box and locate L2 terminal on the changeover PCB Next connect the Black Norsk cable to the Neutral us bar from the main DB box and route it to the DB inverter box and wire it into the terminal marker N on the changeover PCB Using another Norsk cable join the earth in the DB inverter box
11. ot run placing the unit in a low power drain mode preserving the energy in the battery for when you need it Whenever there is power from the grid the battery is always maintained at full power via the internal battery charger Mains Input The Mains Input is used to charge the battery but it also supplies power to the load irrespective of the state of charge of the battery through the changeover switch Ensure that the On Off switch is in the Off position before connecting A grid supply circuit monitors the mains and while the grid is supplying power the grid power is passed onto the load through the changeover switch As soon as the grid supply falls away due to load shedding or whatever reason the inverter is switched on provided the On Off switch is in the on position and the load is connected to the inverter As soon as the mains returns the load is immediately switched over to the mains and the battery starts charging to replenish the used energy Depending on the model purchased which may have 1 or 2 circuit breakers All monitoring and local electronics supply is coming of the number 2 input line When connecting single circuit breaker DB Grid inverters use the number 2 terminal connections on the input side Installation of the DB Inverter Locate the position of the main supply DB box now plan where the DB inverter unit will be installed taking into consideration the wires from the main DB to the i
12. tery sold separately When ordering battery size must be advised so that the unit is set up at the factory for your requirements In accordance with our policy of continual improvement Microsolve C C reserve the right to alter specifications materials and dimensions without prior notice E amp OE Contact details Microsolve C C Tel 27 11 493 5110 P O Box 61014 Fax 27 11 493 5114 Marshalltown email microsolve icon co za 2107 Web www microsolve co za
Download Pdf Manuals
Related Search
Related Contents
Pioneer DV-58AV User's Manual CIRCULAIRE n° 1266 DU 20/10/2005 OBJET いと吉はすぐにお買いあげの販売店にお申し出く ださい。 0万一故障し蓮 60" Laser ARF Instruction Manual FSP/Fortron FSP220-60LE power supply unit Manhattan 161091 Samsung ML-5010ND Mono Laser (48 ppm) Manual de utilizare Really Important Numbers! Copyright © All rights reserved.