1. MiWSN Wireless Sensors Network Mi Sensor 1 and Mi Gateway 1 User Manual MiWSN Contents Certifications FCC and IC 1 Mi Sensor 1 L I 1 2 1 3 1 4 1 5 Sensor Introduction Battery Installation Sensor Installation Sensor Notifications Sensor Precautions 2 Mi Gateway 1l 2d Ze 2 3 2 4 Zed 2 6 ZF 2 8 2 9 Gateway Introduction Gateway Installation Gateway Reset Gateway Repeater Function Gateway Web Management Interface Gateway Login Authentication Setup Page Rebooting Page Configure Page 2 10 Configuring Page 2 11 Status Page 2 12 Help Page Warranty Information Limitation of Warranty and Remedies Certifications FCC and IC Contains Mi Sensor 1 FCC ID AUF S1 and Mi Gateway 1 FCC ID AUF G1 www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 Se ON DAMN Ua aaa R KR WH WH amp H W WNW ae a KR HR QU N N This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Contains Mi Sensor 1 IC 10170A S1 and Mi Gateway 1 IC 10170A G1 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interferenc
2. Low 12 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 RSSI Received Signal Strength Indicator measurement in dBm from the message sent by the sensor This is an indication of signal quality with 7 being the best and 91 the weakest Refresh selecting this button refreshes the messages displayed Clear selecting this button deletes all status messages 2 12 Help Page The gateway has a basic help page built in to aid the user when the User Manual is not handy 13 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 Warranty Information If it does not work return it and it will be replaced for the cost of shipping and handling Does not include abuse or batteries Limitation of Warranty and Remedies Use at your own risk 14 14
3. Reset the sensor battery was inserted or a battery is very low 3 The gateway name plus the sensor name plus an event number signifying where the message came from The event number is incremented each time the sensor sends a message Temp indicates the current temperature C indicates Celsius and F indicates Fahrenheit RSSI indicates the signal strength of the message received by the gateway The farther away from the gateway the sensor is the lower the signal strength will be Signal strength is measured in dBm units 1 5 Sensor Precautions amp Do not place the sensor in liquid Do not expose the sensor to heat in excess of 85 degrees Celsius Do not drop the sensor onto a hard surface 4 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 Mi Gateway 1 2 1 Gateway Introduction p The Mi Gateway 1 receives wireless messages from multiple Mi z Sensor 1 sesnors and sends them to an email account or text message to a phone using your Local Area Network LAN to Internet connection The Mi Gateway 1 has a built in web server that is accessed with any web browser to configure all parameters of the Mi Gateway 1 and Mi Sensor 1 The Mi Gateway 1 plugs into your LAN and is powered from an AC outlet 2 2 Gateway Installation Connect the gateway to your router or local area network using the supplied CAT 5 cable If required a CAT 5 cable up to 30m 100 feet maybe used You
4. Status Motion Alarm Motion Threshold Moisture Contact Alarm Battery Alarm Temp C High Alarm Temp C Low Alam 10 Report Period Min Configure Copyright Gorko Systems Inc 9 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 Sensor Name used to identify the sensor messages displayed on the Status page and in Email messages Motion Alarm the sensor has an accelerometer that will indicate Yes when motion is present and No when no motion is present The sensor can send an alarm on detecting motion or absence of motion Motion Threshold is the sensitivity to motion 1 most sensitive 99 least sensitive Moisture Contact Alarm the sensor has a Moisture Contact input which indicates Yes when contacts have moisture across them or are shorted and No when the contacts have no moisture or are open A length of wire can be attached to the sensors to bring the end points close to the moisture contact being monitored The sensor must not get wet Battery Alarm occurs when the sensor battery needs replacing Temp High Alarm occurs when the sensor temperature becomes greater than the specified temperature in degrees Leave blank to ignore Range is 30C to 60C Temp Low Alarm occurs when the sensor temperature becomes less than the specified temperature in degrees Leave blank to ignore Range is 30C to 60C Report Period the sensor will send a periodic report at pro
5. by sensors The Status parameters are described in the following paragraphs Mi Wireless Sensor Network v1 Setup Configure STATUS Report Report Temp Moisture Time Type C Contact Test 0 00 11 10 Test No 18 No OK 2 72 Test 0 00 10 55 Alarm Yes 19 No OK 272 Test 0 00 09 54 Alarm N 21 Yes OK 2 72 Test 0 00 09 27 Alarm No 7 No OK 2 73 Test 0 00 08 30 Alarm I 31 No OK 2 73 Testl 0 00 06 40 Report 22 No OK 2 73 Testl 0 00 01 53 Report N 20 No OK 2 75 Testl 0 00 00 51 Reset I 21 No OK 2 68 s4 0 00 00 10 Test 18 No OK 244 Battery Voltage KSSI Name Copyright Gorko Systems Inc Name of the sensor Report Time in Days Hours Minutes Seconds since the sensor sent the message Report Type of message sent by the sensor Config is sent after successful sensor configure Test is sent when the sensor test button is pressed quickly Reset is sent on very low battery or replacement Alarm is sent when an alarm condition is detected and Report is sent on programmable time intervals if the Report Period is not zero Test Reset Alarm and Report messages will cause an Email to be sent to the Notify Email Address Motion state of Motion sensor No or Yes Temp current sensor temperature in units specified in the Setup Page Moisture Contact state of sensor Moisture Contact input Yes for wet shorted and No for dry open Battery state of sensor battery condition OK or
6. e including interference that may cause undesired operation of the device 2 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 1 Mi Sensor 1 1 1 Sensor Introduction The Mi Sensor 1 is a multifunction battery powered wireless sensor capable of simultaneously monitoring Temperature Motion and Moisture present or Contact closure Open sensor by prying case open by hand Insert CR2032 battery in holder ensuring to observe polarity indicator on battery and battery holder WARNING Incorrect installation will damage sensor and void warranty 1 3 Sensor Installation Configure sensor using gateway CONFIGURE page See gateway sensor configuring section for details Test sensor signal strength at the location the sensor is intended to be used by pressing the test button on the sensor and viewing the sensor message signal strength RSSI on the gateway STATUS page If signal strength is too low or the gateway is unable to receive the sensor test message try adjusting the sensor and gateway orientation and location Additional gateways may be used to extend range For temperature and motion sensing the sensor only needs to be placed in a suitable location If the sensor is being use to sense the presence of a liquid or contact closure attach the supplied sensing wire to the sensor moisture contact terminal block Each of the two wire ends are inserted into the two larger terminal block holes You
7. grammable intervals Range is 1 to 9999 minutes Enter 0 to disable reports A non calibrated clock is used Configure selecting this button will place the gateway in the Configuring mode When in this mode sensors can be configured with the above parameters by holding the sensor test button for at least 5 seconds 10 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 10 Configuring Page This page allows sensors to be configured with the Configure parameters Sensors should be close to the gateway when performing this operation Mi Wireless Sensor Network v1 Press and hold sensor button for 5 seconds and then release to configure Copynght Gorko Systems Inc Selecting the OK button will cancel the Configuring mode and take the user to the STATUS screen where if a sensor is correctly configured a Config Report Type will be displayed for the configured sensor If you do not see a Config Report Type the sensor test button was not held for greater than 5 seconds or the sensor is out of range Mi Wireless Sensor Network v1 Setup Configure STATUS Rep ort Report Motion Temp Moisture Ba ttery V oltag e RSSI Time Type C Contact Test 0 00 00 02 Config No 19 No OK 2 172 40 Copyright Gorko Systems Inc 11 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 11 Status Page This page displays the most recent messages reported
8. may use your own supplied 18 24 AWG wire if the supplied wire is not suitable for your application To release the wire from the terminal block insert a pin into the two smaller slots of the terminal block For moisture sensing the other ends of the wire should be spaced about 3mm 1 8 inch apart and placed in a location where they can come in contact with the liquid For contact sensing the other ends of the wire should be attached to a dry contact closure element such as a door open close contact containing a reed switch 3 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 Attach double sided tape to the sensor and then attach sensor to its final sensing location 1 4 Sensor Notifications The sensors will send notification to the email account specified in the gateway Setup page Notifications consist of alarm conditions or periodic reports as defined in the Configure Page of the gateway and configured into the sensor Notifications are delivered as email or phone text messages with the subject line fields separated by commas and formatted as follows t O Y From Subject Received Ej me MISH Test WSN Test 58 Motion No ntck No Bat 0K Temp 19C RSSI 39 2301 2012 2 24 PM Indicates the message type Types are Test the test button on the sensor was pressed Alarm an alarm notification condition exists with Motion Cntct Bat or Temp Report sent periodically if configured
9. n acting as a repeater the gateway does not need to be plugged into a LAN Temp Units specifies Fahrenheit or Celsius temperature units IP Type the gateway will use Static or Dynamic IP addressing to join the local network If dynamic addressing is used the gateway gets the next 5 parameters from the local DHCP server If static addressing is used the user specifies the next 5 parameters IP Address is the IP Address of the gateway Subnet Mask is the Subnet Mask of the gateway Gateway if the IP address the gateway uses for external access Primary DNS and Secondary DNS is the first and second IP addresses the gateway uses to resolve Internet names Enable Emails Enable sending Emails for messages reported by sensors SMTP Server and Port is the name and portof the outgoing Email server Use SSL to encrypt email use SSL SMTP Account and Password is the account name and password used for authentication Notify Email Address is the email address used to send messages to Messages are formatted in the subject line of the Email Multiple email addresses separated by a comma may be used Save Reboot selecting this button will save all Setup parameters and reboot the gateway if needed Test Email selecting this button will send a test email to the Notify Email Address to verify that Email parameters are setup correctly A success or fail message will be displayed after the send is complete Thi
10. r network should have a DHCP server connected to it in order for the gateway to receive its initial IP address Connect the gateway to an AC outlet using the supplied AC DC adapter The green link LED on the gateway should turn on You should see periodic pulses on the orange activity LED Place the gateway in a location that provides the best reception of sensor messages The gateway has the best reception when attached to a vertical surface using the provided adhesive pads Other orientations will work but may be less sensitive to sensor messages 5 d Access the gateway management interface using your web browser to configure the gateway and sensors as described in the following pages 2 3 Gateway Reset If you need to reset the gateway parameters to the original factory settings you can perform the following steps all previously stored gateway settings are lost and the sensors will retain their configured settings a Remove power from the gateway b Press the Reset button c Apply power to the gateway d Hold the Reset button for at least 5 seconds e Release the Reset button 2 4 Gateway Repeater Function The gateway may be used as a repeater to extend the range of the gateway connected to the local area network LAN When in this mode the gateway does not need to be connected to the LAN and may be placed in any location within range of an existing gateway and where power is available 5 14 M IWS N ww
11. raphs Mi Wireless Sensor Network v1 User IP Type User Password IP Address 192 168 0 107 MAC Address Subnet Mask Gateway Primary DNS Secondary DNS Temp Units Enable Emails SMTP Server smtp gmail com SMTP Port Use SSL SMTP Account your email address gmail com SMTP Password Notity Email Address your email address qmail com Save Reboot Copyright Gorko Systems Inc User ID and User Password provides secure access to the gateway web interface Leave these blank for no authentication MAC Address is the 6 byte hex MAC address of the gateway Each gateway must have a unique MAC address on the IP network Host Name is the name of the gateway You enter this into the web browser to access the web management interface This is the network name reported in Emails The default is WSNG 7 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 RF Channel is the channel the network operates on Valid channels are 0 to 15 Channel 0 is 2405 MHz and Channel 15 is 2480 MHz Channel spacing is 5 MHz RF Key is a 2 byte hex key used to encrypt RF messages Only messages encrypted with the correct key will be processed RF Repeat this will enable the gateway message repeater function When this is set to Yes the gateway will retransmit valid sensor messages This retransmission allows the gateway to be used as a repeater to extend the range of sensor transmissions Whe
12. s can be received within a second but may take approximately 60 seconds if incorrect parameters are set The received email subject will indicate that it is from the MiWSN network is a TestEmail and which gateway it came from t O From Subject Received Y 3 me Miw SM1 TestEmail SMG 2afO1fe01l2 2 24 PM 8 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 8 Rebooting Page When parameters are changed that affect the network operation the gateway will automatically reboot and the web browser will present the Setup Page after a successful boot If wrong network parameters were saved and the gateway does not respond you can reset to factory defaults by holding down the button on the gateway for 5 seconds when turning power on Mi Wireless Sensor Network v1 Rebooting please wait Changing Host Name IP or MAC address may make it necessary to clear the address caches in your web browser and OS Copynght Gorko Systems Inc 2 9 Configure Page This page is used to enter parameters needed for the operation of a sensor The sensor will save these parameters Sensor defaults will be loaded by holding the sensor test button for at least 5 seconds when the gateway in not on the Configuring page The defaults do no monitoring and report nothing power savings when not in use The Configure parameters are described in the following paragraphs Mi Wireless Sensor Network v1 CONFIGURE
13. w MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 5 Gateway Web Management Interface The gateway management interface may be E wend Ga x accessed using your web browser Type the name of the gateway in your web browser address bar The default name of the gateway 1s http wsng If your network does not support name resolution you should type the IP address of the gateway into your browser You can find this address in your DHCP server s active client list After successful login to the gateway you will be presented with the Setup Page 2 6 Gateway Login Authentication By default the gateway does not require you to provide a HOC login name and password If you have enabled login The server wsng 80 requires a username and password The authentication you will be presented with a login e authentication dialog similar to the following Enter the UserNome OE User ID and User Password parameters specified in the password OOOO SEA Setup Page If you forget your User ID and Password you may Reset the gateway to default settings 6 14 M iWSN www MiWSN com Copyright Gorko Systems Inc User Manual Rev1 1 2 7 Setup Page This page has one time setup parameters needed to specify the local IP network RF network and SMTP email Enter the parameters and use the Test Email button to verify that they work before pressing the Save Reboot button The setup parameters are described in the following parag
Download Pdf Manuals