Home

20150819 ~ FORBO-EUROCOL-NL ~ 950-europlan

image

Contents

1. definitely prime it using one of the primers listed above e Cracks seams in the subfloor should be affixed using 021 Euroblock Reno combined with 063 Euroband and 846 Quartzsand or using 808 Eurojoint Connector in combination with 021 Euroblock Reno e For asphalt floors and bituminous substrates please contact our Technical Advice department e Calcium sulphate bound subfloors anhydrite should be levelled using 925 Europlan Alphy Direct or 920 Europlan Alphy e Always consult our technical product data sheets in advance If you have any doubts about using a product contact our Technical Advice department in advance User manual Processing conditions Recommended environmental temperature 18 23 C Temperature for material and subfloor min 15 max 20 C Relative humidity 40 70 Directions for use e Add 19 kg 950 Europlan Easylight to 5 25 litres of cool clean tap water When combined with 811 reno fibres 5 5 litres of water should be used e Mix the mortar mechanically using the Eurocol 855 Mixing Iron to obtain a smooth lump free product e Allow the mixed mortar to rest for about 3 minutes and then briefly mix at a low rpm e Apply the mortar to the floor within 20 minutes using a smoothing trowel or notched spreading comb e If pumping the 950 Europlan Easylight set the mixing unit so that 5 25 litres of clean tap water is added per 19 kg of 950 Europlan Easylight e Protect fresh levelling layers pro
2. eurocol 5 950 EUROPLAN EASYLIGHT Self smoothing lightweight levelling compound for stony and wooden subfloors Product Typification Basis Cement powder with lightweight additives and synthetic binding agents Colour Grey Consistency Powder e Lower burden on the floor construction e Applicable in ships e Very low VOC emissions Emicode EC 1 plus e Less dust e High coverage efficiency e Self smoothing e Good flow out e Pumpable e High compression strength e Office chair proof e Maximum layer thickness 15 mm Performances Flammability gt Non flammable Bending Strength According to NEN EN 13892 2 2002 2 8 N mm after 28 days Bureau Wheelchair resistance From 2 mm layer thickness Compressive strength In accordance with NEN EN 13892 2 2002 2 32 N mm after 28 days Passableness 1 5 2 hours at 18 20 C Consumption About 1 3 kg m per mm of layer thickness Application To level cement bound and other stony subfloors in layers of no more than 15 mm For use on ships a maximum layer thickness of 10 mm is permitted Also applicable to wooden floor constructions finished with wood or cement fibre sheets that need to be covered with floor covering For pumping Consult with the pump supplier to determine whether the pump is suitable for all types of levelling compounds Pumps with a very high mixing speed may result in insufficient flow out of the levelling compound Working Process St
3. orage Store in a cool and dry place Tools Smoothing trowel or notched spreading comb a spiked roller mix pump installation Mixing ratio 19 kg 950 Europlan Easylight with 5 25 litres of water Processing time Binnen 20 minuten na het mengen Latency It is recommended the mortar be allowed to cure for about 2 minutes Drying 24 hours Shelf Life 6 months in unopened packaging The mentioned values have been established in our laboratory and must be considered as guidelines in view of possible variations in climatic circumstances subfloor compositions and layer thickness Substrate e 950 Europlan Easylight can be applied to any rigid pressure and tension resistant stony and wooden subfloor The subfloor must also be clean permanently dry and free of grease or dirt in accordance with the requirements of DIN 18 365 e Smooth and sealed subfloors tile floors granito terrazzo etc should be degreased thoroughly using e g 014 Euroclean rinsed sufficiently and allowed to dry completely Next the layer as well as sanded old waterproof glue remains prime using 044 Europrimer Multi using a foam roller e Porous cement floors cement fibre and wood sheeting should be primed with 044 Europrimer Multi 049 Europrimer ABS or 099 Dispersion primer using a pile roller e Holes and deeper gashes should be filled in advance with 905 Europlan Fill 945 Europlan Solid Once the 905 Europlan Fill 945 Europlan Solid has hardened
4. tect against drafts and direct sunlight e Under normal circumstances the levelling layer can be walked on after 1 5 to 2 hours For a Layer thickness of up to 5 mm the levelling layer is ready for further processing after 24 hours e For use in ships or a layer thickness greater than 10 mm 806 Foam Strip Profil should be installed prior to levelling e For extensive information about the safety measures required we refer you to the material safety data sheet at our website www eurocol com Underfloor heating constructions 950 Europlan Easylight may be used for underfloor heating constructions The start up protocol for the floor heating must be performed in advance and in full accordance with the supplier s guidelines Turn off the heating one day before levelling wait at least 24 hours after levelling before turning on the underfloor heating again in steps of no more than 5 C of water temperature per day Quality and guarantee Environment and health Hazard Class Xi irritating MSDS Available on request Articles Article Definition Packaging EAN code 950 Europlan Easylight 19 kg 8 710345 950107 the strong connection

Download Pdf Manuals

image

Related Search

Related Contents

"取扱説明書"  Samsung Induktiokeittotaso CTN264EA01 Käyttöopas  INSTALLATION MANUAL    1 - Sony  Ektron CMS400.NET User Manual  

Copyright © All rights reserved.
Failed to retrieve file