Home

AccessZone GC400 User Manual HW rev 03 - MVC

image

Contents

1. O022B4B62508 gt Bluetooth ID 0022B4B62508 is send 10 8 Wiegand 40 with XOR checksum 08 Wiegand 40 with XOR checksum Uses a non standard Wiegand format with 3 ID bytes Instead of the MSB and LSB parity bits a 8 bit XOR checksum is used Frame format 8 bit 24 bit 8 bit Facility code of Bluetooth ID XOR checksum Frame The facility code with the last 3 bytes LSB of the 6 byte Bluetooth ID is sent together with an 8 bit XOR checksum A total of 40 bits 8 24 8 In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID B62508 is send All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 28 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 10 9 Wiegand 56 with XOR checksum 09 Wiegand 56 with XOR checksum Uses a non standard Wiegand 26 format with 5 ID bytes Instead of the MSB and LSB parity bits a 8 bit XOR checksum is used Frame format 8 bit 40 bit 8 bit Facility code of Bluetooth ID XOR checksum Frame The facility code with the last 5 bytes LSB of the 6 byte Bluetooth ID is sent together with an 8 bit XOR checksum A total of 56 bits 8 40 8 In example
2. GC400 Series GC401 GC404 User Manual MVC Data 3 Security Precautions Several security precautions have been implemented in the system to make it safe to use The system will only accept system configuration commands in a special configuration mode refer to section 7 2 How to enter Configuration Mode All system configuration commands are entered by temporarily changing the mobile phones friendly name and must be followed by a unique 8 digit Master PIN code The Master PIN code should only be known to a limited number of people system administrators The 8 digit Master PIN code should be changed and is unique for each GC401 GC404 system It can be entered from any Bluetooth enabled mobile phone Please change the Master PIN code before continuing Two privileged users administrators can add and delete users at any time Refer to section 7 4 How to Add or Delete Users Normal Operation Caution The Bluetooth friendly name feature is used for commands and can be read from another Bluetooth device from the distance typically up to 10 meters Therefore it is highly recommended to immediately change the Bluetooth friendly name again or make the mobile phone invisibly to avoid that unauthorized people read the commands containing vital user information All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Co
3. LSB parity makes a total of 26 bits 1 8 16 1 in each frame The Wiegand controller must be able to combine these frames In example Read Bluetooth ID 0O022B4B62508 gt Bluetooth ID B4B6 is send in frame 1 and Bluetooth ID 2508 is send in frame 2 10 3 Triple Wiegand 26 03 triple Wiegand 26 frame Same as Wiegand 26 but the Bluetooth ID is sent in 3 Wiegand 26 frame with 25 ms delay between Frame 1 The facility code and the last 2 bytes LSB of the 6 byte Bluetooth ID is sent Frame 2 The facility code and the next 2 bytes middle of the 6 byte Bluetooth ID is sent Frame 3 The facility code and the first 2 bytes MSB of the 6 byte Bluetooth ID is sent A even MSB parity bit and a odd LSB parity makes a total of 26 bits 1 8 16 1 in each frame The Wiegand controller must be able to combine these frames In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID 0022 is send in frame 1 Bluetooth ID B4B6 is send in frame 2 and Bluetooth ID 2508 is send in frame 3 l e the full 6 byte ID is send 10 4 Wiegand 34 04 Wiegand 34 Uses the classic Wiegand 26 format but with an additional ID byte Frame The facility code with the last 3 bytes LSB of the 6 byte Bluetooth ID is sent A even MSB parity bit and a odd LSB parity makes a total of 34 bits 1 8 24 1 In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID B62508 is send All information
4. MOG dasiscicastierssansicicasneainaeaamseentagieeeeemneaminniamammeen 30 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 3 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 12 USER ACCESS key SOUP iss cncccsacctacesentanccsancgecerantecacyseceesmoetsagnaaneteaniceretanautt ann ena 31 12 1 Mobile Phone as i etersntcsen Seen ngs as os nase cbse seaceuerancnhasten tea mandimtanmscestoatequessamstansaal 31 12 2 GPS Key aS KO Vici ceciass ccasaseu venga ve icine aie cade eelezenduaivaaascaaivancsandinaesaes E AER 32 12 3 Acc ssZ ne Bluetoothi Tagsir A R EEN 32 13 ACCESS Detection Rane Eeri E E A E aR 33 13 1 Detection Range Command Exam les iisxsisdagscossoseeeanss onyt e aiai 33 13 2 Detection range IS TO SIMON tusiina E a aaa 34 13 3 Detection range is too long cruscraminiinn a E a EE E AEA 34 14 De fa lt Factory System Setting Saienisi n a a a a 35 14 1 Restore Factory Default System S ttings 0 csssssescsenssanscsoeosnessscacasesteasavessonnnsseaauseseansoannoas 35 15 Appendix A User Log Templat E is ciccicssaccecesscansiesanaceasaagarewesaceneinoantasianacananeeeiaeiiasadoiancieewensesuawiae 36 16 Appendix B System Master PIN Code Log Templates s
5. Read Bluetooth ID 0022B4B62508 gt Bluetooth ID 22B4B62508 is send 10 10 Wiegand 64 with XOR checksum 10 Wiegand 64 with XOR checksum Uses a non standard Wiegand 26 format with all 6 ID bytes Instead of the MSB and LSB parity bits a 8 bit XOR checksum is used Frame format 8 bit 48 bit 8 bit Facility code of Bluetooth ID XOR checksum Frame The facility code with all 6 bytes of the Bluetooth ID is sent together with an 8 bit XOR checksum A total of 64 bits 8 48 8 In example Read Bluetooth ID O022B4B62508 gt Bluetooth ID O022B4B62508 is send l e the full 6 byte ID is send All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 29 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 11 Virtual Keypad The system has a wireless virtual keypad functionality which can operate in two different modes Virtual Keypad only Mode and Virtual Keypad Mixed Mode This feature will allow access to all users that know the 4 digit access PIN code or to any with a Bluetooth device 11 1 Virtual Keypad only Mode The system can be configured to run as a purely virtual keypad l e no users have
6. for power differences and antenna location between the used Bluetooth keys e g mobile phones fa device must be closer to the reader than most others before access is granted set parameter 3 weak device fa device gets access further away from the reader than most others set parameter 1 strong device Default is 2 standard device All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 15 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data Total length 20 digits or optional 22 digits Examples Examples On position 1 add unique user 0022b4b62918 with PIN code 1234 enter 01 0022b4b62918 1234 On position 5 add unique user 0022b4b62918 without PIN code enter 05 0022b4b62918 0000 On position 1 add unique user 0022b4b62918 without PIN code and strong enter 01 0022b4b62918 0000 1 On position 5 add unique user 0022b4b62918 without PIN code and weak enter 05 0022b4b62918 0000 3 Note Any exiting user on the storage position selected will be erased l e it is not necessary to erase an existing user first System administrator should maintain a system log of users and storage positions used Please see 15 A
7. is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 27 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 10 5 Wiegand 42 05 Wiegand 42 Uses the classic Wiegand 26 format but with two additional ID byte Frame The last 4 bytes LSB of the 6 byte Bluetooth ID is sent together with the facility code A even MSB parity bit and a odd LSB parity makes a total of 42 bits 1 8 32 1 In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID B4B62508 is send 10 6 Wiegand 50 06 Wiegand 50 Uses the classic Wiegand 26 format but with tree additional ID byte Frame The last 5 bytes LSB of the 6 byte Bluetooth ID is sent together with the facility code A even MSB parity bit and a odd LSB parity makes a total of 42 bits 1 8 40 1 In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID 22B4B62508 is send 10 7 Wiegand 58 07 Wiegand 58 Uses the classic Wiegand 26 format but with 4 additional ID byte l e the full Bluetooth ID Frame All 6 bytes of the Bluetooth ID is sent together with the facility code A even MSB parity bit and a odd LSB parity makes a total of 58 bits 1 8 48 1 In example Read Bluetooth ID
8. system However it is possible to add some unique Bluetooth IDs with an optional 4 digit PIN code for increased security l e the Bluetooth ID will first be sent to the central access controller for final access verification after the unique PIN code has been entered by the user The used mobile phones or other Bluetooth devices must be set to visible to allow them to be discovered by the system The GC400 series eliminates the need for mechanical readers and keyboards outside the secured area This removes the risk for property damage and breakdown due to harsh environmental conditions and heavy use Please refer to the GC400 Firmware Release Note for the latest changes The latest firmware versions introduces New easy user enrolment method It can be used to add users to the system without entering knowing the Bluetooth ID of the used mobile phone Only storage position and access PIN code must be entered New system commands Added support for two new groups of system commands to make administration easier System commands E01 E07 and System configurations commands C01 C06 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 6 40 AccessZone
9. uniquely identify the reader on the Wiegand bus The number should be uniquely selected to avoid 2 digits duplicates in a system The number is entered 0x00 0xFF as a hexadecimal number E g 0x20 is written as 20 0x00 00 0 and OxFF FF 255 Default 20 32 The number selects the Wiegand frame format to used 01 Wiegand 26 de facto 02 double Wiegand 26 frame 03 triple Wiegand 26 frame 04 Wiegand 34 2 digits 05 Wiegand 42 1 10 06 Wiegand 50 07 Wiegand 58 08 Wiegand 40 with XOR checksum 09 Wiegand 56 with XOR checksum 10 Wiegand 64 with XOR checksum E g 01 is written as 01 Default 01 Wiegand 26 lt Wiegand facility code gt lt Wiegand type gt Total length 5 digits Example To select facility code 5 and standard Wiegand 26 enter 05 01 To select facility code 255 and standard Wiegand 58 enter FF O7 Refer to section 10 Wiegand Types The system settings can be reset to factory value Please see section 14 Default Factory System Settings System administrator should maintain a system log with changed System Settings for Normal Operation Mode Please see 17 Appendix C System Configuration Log Template All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright
10. user list and adds the E05 3 digits default Any user FFFFFFFFFFFF on storage position 01 as new administrator RRR R Increases the RX range to allow access to the Decreases the RX range to allow the users to be E07 3 digits closer to the reader before access 3 dBm steps Note The system also supports small letters E g e01 e02 etc The System Reset command E01 is useful when new firmware must be uploaded to the module This is similar to reapplying the power 2 These commands can be executed again and again to allow easy adjustment of the RX range The command changes the third parameter of the System Configuration Command 2 e g 2 6 50 0 0 1 1 This mean that command E06 adds a value of 3 to the lt Detection range gt parameter And E07 subtracts a value of 3 to the lt Detection range gt parameter E g start condition 2 6 50 0 0 1 1 E06 is executed twice and the new setting is 2 6 56 0 0 1 1 etc The limits 00 or 99 are reached when 2 beeps are heard and the system will stop prompting for the administrator PIN code If this is not enough the TX range must be adjusted Refer to the figure in section 8 6 for more information about the RX range All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data
11. 04 User Manual MVC Data 8 2 Add new User Command This command adds a new user to the system This is also used for editing an exiting user Make sure to store the user on the same storage position This command can also be execute in normal mode by the privileged users administrators on storage position 01 and 02 Parameters Values Description Position in system database to store the user 2 digits 01 02 Privileged users administrators 01 02 03 07 Normal users GC401 03 07 03 12 Normal users GC402 03 12 03 22 Normal users GC403 03 22 03 52 Normal users GC404 03 52 E g position 1 is written as 01 The unique Bluetooth address of device lt Add storage position gt lt BD address of new device gt 12 digits Valid values 0 9 and A F or a f E g O01256ABCDEF OOBB592F030B User access PIN code Eg 12354 Use 0000 to disables use of access PIN code for that particular user Device power class lt power class gt ae 1 strong device 2 standard device optional not required 3 weak device Default 2 lt PIN code for user gt 4 digits 1 The privileged users administrators should be added with a PIN code 2 The access PIN code must be entered within 15 seconds before it continues to scan for another user 3 Can be used to compensate normalize in some degree
12. 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 20 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 6 Change System Configuration Command 2 Advanced settings This command can change some additional system settings and thereby customize the system to your requirements Caution Caution must be taken when changing these system configuration parameters Please refer to section 13 1 Detection Range Command Examples Parameters Values Description Maximum transmit power range TX me V 0 1m 2m lt power range gt FA 2 0 5m 10m 3 5m 100m Default 1 idi System transmit power TX level lt TX power level gt amp 1 0 1 m 8 10 m 1 8 iz Default 3 IR Device detection range RX i 2 digits DA men lt Detection range gt 00 shortest distance 99 longest distance 00 99 Faro Default 40 1 digit O low active GND 1 high active open SE eevee Oor1 Default 0 NOT USED 1 digit O low active GND 1 high active open lt Input2 active level gt Sart Default t O low active GND 1 high active 12V DC lt Output1 active level gt Open collector output for alarm light Default 1 NOT USED O low active GND 1 high active 12V DC lt Output2 active level gt Open collector output for gate do
13. 5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 12 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 7 4 How to Add or Delete Users Normal Operation Privileged users administrators are stored on storage position 01 or 02 These two privileged users administrators are allowed to add and delete users from normal operation mode l e it is not necessary to enter configuration mode first The user administrator might be prompted to first enter the normal access 4 digit PIN code if access PIN code is required and then the 8 digit Master PIN code if a valid and new Add new User or Delete User command has been found A short beep indicates that the command has been successfully executed as in normal configuration mode TIP Make sure that the mobile phone used is stored on position 01 or 02 and have an access PIN code recommended before continuing It will not accept commands in this mode if PIN code is not used Follow these steps to add or delete a user Steps 1 Enter the required Add new User or Delete User command on the mobile phone and click save refer to section 8 2 Add new User Command and 8 4 Delete User Command 2 Set the mobile phone to visible 3 Place mobile phone within the detection range of the system 4 Enter normal access PIN e g 1234 when prompted ID is sent on Wiegand bus if correct 5 Wait for 3 short beeps 6 Enter Master P
14. 50 users A GC500 series is also available as a stand alone access control systems AccessZone G6C501 GC504 with 2 5 2 10 2 20 and 2 50 users A AccessZone GC400 with Please see the GC400 series Installation Manual for instructions on how 3 inputs 2 outputs to install the system Form factor 127 x 47 x8 mm Get easy and seamless accesses to the secured areas with your mobile phone working as a secure access key from a distance of 0 1 up to 10 meters All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 2 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data Table of Contents IAE e MM era ca A E ss E mnse une A AE E E E A E EAE A cc T testa 5 2 Mro duction sicco E eee 6 3 SECUrIY PRECAUTIONS vxccericaravedcora cave naa A N A A EAA ORA 4 A System OVEFVIE Wieniin aide A E A aA an E O A RA 8 SIO DEScHip UO Ma E T 8 SA MPU Sn nenon N E E EA EAEE 8 SZ OUUDUUS nnn anna E EEA EE a E EAE EE EEE 8 S LED ec ce Sanen ee ne ere oe aaa aaa a a 9 EPO MOT UD an AN EE E I E E E E A A E EE 9 6 2 Blue LED icneriesnineineccinnen oinen E a E aarian 9 6 2 Green WED 7 Ext Red VED vc cnastssicacariciacinsiiameauaiaisnetaisventiaasspndanimiaiaiomasnuaa
15. AccessZone GC400 Series GC401 GC404 User Manual MVC Data GC400 Series GC401 GC404 User Manual New Generation of Wireless ccess Control Systems User Manual for GC401 GC404 with firmware Ver 0 52 and above HW revision 03 For modules with serial numbers from 0011009 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 1 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data AccessZone System A Key to a Safer Future Congratulations on choosing an AccessZone GC400 Bluetooth Reader It is a flexible and easy to use system for controlling access to doors and gates to private homes shops and small and middle size companies It enables quick configuration with a few simple commands entered on a standard mobile phone with Bluetooth without installing any software No license or subscription is required The Bluetooth ID is send on the Wiegand bus to an external access controller This manual covers the easy configuration and use of the AccessZone GC400 series of Wiegand Bluetooth Readers GC401 2 administrators and 5 users GC402 2 administrators and 10 users GC403 2 administrators and 20 users GC404 2 administrators and
16. ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 23 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 8 Execute System Configuration Advanced settings Supported from firmware version 0 52 This section describes some predefined system configurations which helps adjusting the system to the required detection distance The configuration commands can easily be executed from the administrator mobile or from any mobile phone when in configuration mode The system will automatically perform a system reset to allow the new settings to take affect Caution Caution must be taken when changing these system configuration commands The settings might be influenced by local installation conditions and need further adjustment Command Values Description Very short range 10 cm Col 3 digits Corresponds to the system command 1 2 30 X X X X Door access short lt 50 cm COZ 3 digits Corresponds to the system command 1 4 50 X X X X Door access normal lt 2m Cos 3 digits Corresponds to the system command 2 3 60 X X X X Gate access lt 5m cog 3 digits Corresponds to the system command 2 6 70 X X X X Gate access long lt 10 m 05 3 digits Corresponds to the system command 2 8 80 X X X X Very long range lt 100 m COG 3 digits Corresponds to the system command 3 8 99 X X X X Not
17. IN code e g 12345678 when prompted 7 Wait for beep for successful execution of the Add new User or Delete User command 8 Set the mobile phone to invisible hidden 9 Erase command from mobile phone If more users must be added deleted repeat step 1 8 7 4 1 If the system doesn t respond to a command The administrator is outside the normal access range of approximately 20 cm Administrator must get closer to the system The command has already been executed Try change one of the parameters or try another command The command is not valid Wrong number of parameters wrong parameter values and or wrong command length e g spaces at the end The system times out waiting to read the command or connection to mobile failed Wait for next detection All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 13 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 System Commands This section describes the simple and easy to use mobile configuration command set for GC401 GC404 the Wiegand series 8 1 Change 8 digit Master PIN Code Command This command changes the Master PIN code which is used to validate all system commands The system will aut
18. Series GC401 GC404 User Manual MVC Data 7 2 How to enter Configuration Mode The system must be set into configuration mode before it will accept the system commands However it is possible for two privileged users administrators to use the Add new User and Delete User commands in normal mode Refer to section 7 4 How to Add or Delete Users Normal Operation 7 2 1 Method 1 Follow these steps to enter configuration mode Steps 1 Power off the module 2 Pull down the buzzer input IN2 to GND 3 Power on the module again 4 The buzzer input can be released again after the short beep 7 2 2 Method 2 Enter the system command E02 on the administrator phone and enter the 8 digit master PIN code The system is now in configuration mode for 10 minutes and will flash with the Blue LED Refer to section 7 3 How to enter System Commands Configuration Mode for how to enter system commands The system coverage range will be limited to approximately 20 cm in the configuration period to prevent that unauthorized people can tamper with the system The configuration period is restarted every time a valid command has been executed Configuration mode is automatically terminated after 10 minutes without any valid commands by sending 2 short beeps Alternatively by power cycling the device to startup in normal operation or by sending the system reset command E01 from the administrator mobile phone and the 8 dig
19. US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 32 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 13 Access Detection Range The detection range may be influenced by the surroundings at the installation location indoor or outdoor If metal is close by reflections may increase decrease the detection range It may also vary between the different used devices mobile phones l e some devices have a longer shorter range than others because of different antenna designs and where and how they are placed e g held in the hand or placed in the pocket etc The system has some advanced and unique features to make individual adjustments of the detection range Both the transmitted power TX and received signal power RX can be adjusted to compensate the installation environment and individual requirements And the used devices can be added as a strong standard or weak device to compensate for individual device characteristics If the detection range is not as expected the values can be adjusted up down to find a suitable set of values Please test and adjust as appropriate on location 13 1 Detection Range Command Examples The section shows some typical detection range commands you can use as a starting point to find your own specific values The first to value 1 2 30 0 0 1 1 corresponds to the used
20. aiiauamiumes 9 6 4 Red LED Ext Green ol Aan mee naa reese eee ERT n n ERT aidia 9 POs COCO SUS the Systemerne a E eed a Ua aoa 10 7d COMMAS Vie IMIGING ccccizasceseazcdceincadininainiaeissateaeinaateadnisasiiaes Aaaa 10 7 2 HOW toenter Configuration Wie sis senscusss tes sinspainauandednsunguinmeisroatasuniaaenniunntaneiminnlemmlanaains 11 F AG Wile e ae th aried hate E a ieee 11 TEAPA E TO e EETA E E E A EEN E ET A A a E A 11 7 3 How to enter System Commands Configuration Mode sssssssssesrresssrrrsssrrsssrerrrrrererene 12 7 3 1 If the system doesn t respond toa command ssiiiiieiscissriisereririsieriicinicnsiierninieiienina 12 7 4 How to Add or Delete Users Normal Operation ccccccccecsssececssssececeesseeeceeeeeeeceeeeeeeeeeees 13 7 4 1 If the systein doesn t respond TOS Commandes oscaisnicnseniteinsiasbieniteeunorincutabisiewaXinaeinepieas 13 8 System COMMING Sersrioiinzen naea aoni 14 8 1 Change 8 digit Master PIN Code Comm anA unisini 14 8 2 Add new User Comm aNd arn rani a T E E T 15 8 3Add new User Command Easy Enrolment asineidiccnssisienccacaisnssacanisesnasnasartaatsnniadeiiaeibinenstoneas 17 Default 6 2 standard device i sixisAecrarnenation ieiinaemnuinie nena esa 17 See an example in section 18 2 Adding Users to the System from factory reset Easy MMI ON RN screener dbase Seek ascents crac N E E E A T A toon ened A 18 8 4 Delete User Commanderin a Ei 19 8 5 Change system Configuration Command 1 rs sis
21. and deletes a user from the system This command can also be execute in normal mode by the privileged users administrators on storage position 01 and 02 Parameters Values Description User position to delete from system database Privileged users administrators O1 02 Normal users GC401 03 07 Normal users GC402 03 12 Normal users GC403 03 22 Normal users GC404 03 52 Ex position 1 01 8 08 and 10 10 lt Delete storage position gt Total length 2 digits Examples Delete privileged user administrator stored on position 1 enter 01 Delete normal user stored on position 5 enter 05 Note An exiting user can also be deleted by adding a new user on the same storage position l e it is not necessary to use the delete command first All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 Allrights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 19 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 5 Change System Configuration Command 1 This command can change some Wiegand bus settings and thereby customize the system to your requirements Parameters Values Description The facility code is a number used to
22. and type is by default Wiegand 26 Detection range is approximately 20 40 cm Master PIN code is 12345678 Please change this as the first thing Below is a list of the commands for the default factory settings See how to restore default values in section 14 1 System Master PIN Code 12345678 Default System Settings 1 Normal Operation Mode 20 01 Note Settings in bold is fixed for the duration of the system configuration mode System Settings 2 System Configuration Mode Default System Settings 2 Normal Operation Mode 1 3 40 0 0 1 1 Default User 01 FFFFFFFFFFFF 1234 1 2 30 0 0 1 1 14 1 Restore Factory Default System Settings The Master PIN code and the other system configuration settings can be restored to factory settings Please follow the below steps Steps Power off the device a Disconnect input 2 Disconnect output 1 and output 2 from the Wiegand bus Connect short input 2 with output 1 and output 2 Power on the device Wait a short beep acknowledges that the factory settings have been restored Power off the device again Reconnect input 2 Reconnect output 1 and output 2 to the Wiegand bus Device can safely be re powered with the restored factory settings Caution General caution must be taken when working with the wires to avoid short circuits etc All information is subject to change without notice All other products and brand names are registered trademarks of t
23. ange of the system 6 Wait for 3 short beeps which indicate that a valid command has been found and Master PIN code is required 7 Enter 8 digit Master PIN code on mobile phone when prompt 8 Wait for beep for successful execution 9 Set the mobile phone to invisible hidden 10 Erase the command in the mobile phone For more commands repeat step 2 9 If no more commands are required Set friendly name back to desired name All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 39 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 18 5 Mobile Phone as Access Key Any Bluetooth enabled mobile phone can be used as access key No software has to be installed on the mobile phone The system will detect the mobile phone when it comes within the specified detection range TIP A few mobile phones cannot handle an active pairing or search for devices at the same time Steps 1 Enable Bluetooth on mobile phone and set it to visible Refer to the mobile phone s User Manual 2 Enter the 4 digit access PIN code when prompt Only if PIN code is required Note The time Bluetooth inquiry scan time a mobile phone uses to scan for other Bluetooth devi
24. arks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 8 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 6 LED Status The GC400 series have 3 internally controlled LEDs Blue Green and Red and two externally controlled LEDs Red and Green for system indications The Green LED mid is a dual LED with an additional Red LED controlled though input 3 Orange core The Red LED right is a dual LED with an additional Green LED controlled though input 4 Blue core Dual LEDs 6 1 Power Up The Blue LED and Red LED will light for 2 seconds from power up This is the bootloader waiting for new firmware Bootloader will call the application if new firmware is not received 6 2 Blue LED Normal Mode the Blue LED is solid on It flashes shortly whenever a Bluetooth device ID is read from a nearby Bluetooth device e g a mobile phone Configuration Mode the Blue LED blinks 1 time sec The device can accept commands 6 3 Green LED Ext Red LED The Green LED starts blinking when waiting for user to enter the PIN code The Green LED flashes shortly when an Bluetooth ID has been read and is send on the Wiegand bus The external Red LED is by default OFF leave not connected It can be controlled from an external controller through input 3 Orang
25. ces that want to connect to it is typically set to a low value to preserve battery power l e the time to discover a nearby Bluetooth enabled mobile phone strongly depends on implementation details for a particular mobile phone All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 40 40
26. cissccscssnsadescnciciiaceaasceiasaustacasaadscasanssainaaaeas 36 17 Appendix C System Configuration Log Template iis sssiscaiscds cccuasuedcacesacatuaasiesedescssman Gusheawiasuctavees 36 1S Appendix D OUK GUJE ranures a E E E eka eas tere A commands 37 18 1 Setting as a simple Bluetooth ID reader from factory reset Easy Enrolment 00066 37 18 2 Adding Users to the System from factory reset Easy Enrolment ccssccessssteeeeseseereees 37 18 3 Mobile Phone used for Adding and Deleting Users Normal Operation ccccesseeeeeee 38 18 4 Mobile Phone used for System Commands System Configuration Mode ccccceseceeees 39 18 5 Mobile Phone aS Access NEY cniinne innnan esii iane daa r n eie 40 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 4 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 1 Disclaimer All rights reserved MVC Data ApS assumes no responsibility for any errors in this manual MVC Data ApS is constantly working to improve its products and offer new features in collaboration with customers and partners Therefore MVC Data ApS reserves the right to change the hardware software and or specificati
27. e The system also supports small letters E g c01 c02 etc X means that the I O setting is not affected changed Use the E06 and E07 commands to adjust RX range Refer to the figure in section 8 6 for more information about the TX and RX range All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 24 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 9 How to understand TX and RX parameters The TX and RX range should ideally lay on the same circle It is recommended that the TX range is greater than the RX range Case 1 The user is outside the TX and RX range and the user is not detected by the AccessZone system l e no access allowed TX range Case 2 The user is now inside the TX circle and the AccessZone system can read the unique ID from the mobile phone However access is not allowed because the user is outside the RX range Case 3 The user is now inside the TX circle and the AccessZone system can read the unique ID from the mobile phone The user is also within the RX range and access are allowed All information is subject to change without notice All other products and brand names are registered t
28. e Core The LED is set ON by pulling input 3 down to GND 6 4 Red LED Ext Green LED The Red LED flashes shortly when an Bluetooth ID has been read but it could not be send on the Wiegand bus because it was busy to avoid collisions The external Green LED is by default OFF leave not connected It can be controlled from an external controller through input 4 Blue Core The LED can be set ON by pulling input 4 down to GND All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 9 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 7 Howto Configure the System This section describes how to enter system commands and how to enable the system for configuration Section 8 System Commands describes the different commands in details 7 1 Commands via Mobile System configuration adding deleting users and changing system settings can be done from any Bluetooth enabled mobile phone Note It is not necessary to install any software on the mobile phone or use any PC tool The mobile phone used must support at least 20 characters as Friendly Name also called Phone Name This is the name revealed for other Bluetooth devices A system command e
29. enough increase 1 lt TX power level gt and set lt Detection range gt 50 Check detection distance follow adjusting procedure depending on result Final adjustment can be done by changing 1 the lt Detection range gt value Refer to section 8 8 for commands to adjust TX and RX range 13 3 Detection range is too long Follow and repeat these steps or use system command E07 to shorten the detection range Decrease 3 the lt Detection range gt If lt Detection range gt 0 then decrease 1 the lt TX power level gt value and set lt Detection range gt 99 Check detection distance follow adjusting procedure depending on result The final adjustment can be done by changing 1 the lt Detection range gt value Refer to section 8 8 for commands to adjust TX and RX range All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 34 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 14 Default Factory System Settings Here is a short recap of the systems default settings Virtual Keypad user OxFFFFFFFFFF with PIN code 1234 is default on storage position 01 Facility code is by default set to 20 decimal 32 Wieg
30. ently without affecting the other users Caution The system will start to search for a match from position 01 going up The virtual keypad user must be placed after the last used storage position or store it on the last storage position 7 12 22 or 52 if you want to be able to add more users in the future All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 30 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 12 User Access Key Setup In principal all Bluetooth enabled devices can function as user access keys If entering of PIN code is required the device must have a suitable keypad to enter the code The used Bluetooth device must also be configured to be visible from other Bluetooth devices to allow it to be detected by other Bluetooth devices Please refer to MVC Data How to Get the Bluetooth ID paper http www mvc data com Misc html Note The time it takes to detect a nearby user can be influenced by The time Bluetooth inquiry scan time i e the time a mobile phone uses to scan for other Bluetooth devices that want to connect to it The time is typically set to a low value to preserve battery power The time to discover a nearby Blue
31. er to section 7 How to Configure the System for more details about the different commands 18 1 Setting as a simple Bluetooth ID reader from factory reset Easy Enrolment This example shows how to easily setup the system as a simple Bluetooth ID reader The read ID is send on the Wiegand bus Enter the 4 digit access PIN code 1234 and then the 8 digit master PIN code 12345678 when prompted Mobile phone1 Enter command 01 3423 New administrator Mobile phone 1 Enter command 03 FFFFFFFFFFFF 0O000 Any user A new administrator is added with a access PIN code The Bluetooth ID is send on the Wiegand bus without PIN code for all users 18 2 Adding Users to the System from factory reset Easy Enrolment This example shows how to easily enrol 3 mobile phones and a new system administrator all with unknown BD addresses The command must be entered on the mobile phone to add Enter the 4 digit access PIN code 1234 and then the 8 digit master PIN code 12345678 when prompted Mobile phone1 Enter command 03 2250 Position 3 and PIN 2250 Mobile phone 2 Enter command 04 7822 Position 4 and PIN 7822 Mobile phone 3 Enter command 05 3322 Position 5 and PIN 3322 Add more Mobile phone 4 Enter command 01 3423 Enter new administrator Note The specified positions and user access PIN code is just used as example Caution Remember to change the 8 d
32. g 01 0022b4b62918 1234 is entered by temporarily changing the mobiles Bluetooth Friendly Name Refer to section 8 System Commands Please refer to the User Manual for a specific mobile phone type for how to change the Bluetooth friendly name Caution The Bluetooth specification states a maximum length of 248 characters as Friendly Name However most mobile phones have limited the space allowed for Friendly Name A minimum of 20 characters must be supported by the used mobile phone All commands must be followed by an 8 digit Master PIN code for safe use The system gives 3 short beeps to indicate that a valid command has been found and the Master PIN code is required The user will automatically be prompted when to enter the Master PIN code Note This is not the normal 4 digit user access PIN code Please note when entering the commands All command parameters enclosed by lt gt must be separated by a comma No spaces between or after values are allowed Have the exact length as specified l e no additional characters in the end 7 indicates an integer range 1 2 3 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 10 40 AccessZone GC400
33. heir respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 35 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 15 Appendix A User Log Template Write your log of permitted users and store in a safe place Storage Position User Name Bluetooth Address PIN Code 16 Appendix B System Master PIN Code Log Template Write your Master PIN code here and store in a safe place System Master PIN Code 17 Appendix C System Configuration Log Template Write your configuration setting here and store in a safe place System Configuration 1 System Configuration 2 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 Allrights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 36 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 18 Appendix D Quick Guide Users must first be added to the system with an optional 4 digit user access PIN code before access can be granted All system commands e g add user can in configuration mode be send from a Bluetooth enabled mobile phone as long as the user knows the 8 digit Master PIN code Please ref
34. hich gives a total of 65 536 0 to 65 536 individual ID s Due to the mathematical limitations of the Wiegand 26 format duplicates may occur However if Wiegand 58 is used instead all 48 bit of the unique Bluetooth ID number is send For a general introduction to Wiegand refer to http en wikipedia org wiki Wiegand_ protocol 10 1 Wiegand 26 01 Wiegand 26 frame This is the classic de facto Wiegand 26 frame format Frame The last 2 bytes LSB of the 6 byte Bluetooth ID is sent together with the facility code A even MSB parity bit and a odd LSB parity makes a total of 26 bits 1 8 16 1 In example Read Bluetooth ID 0022B4B62508 gt Bluetooth ID 2508 is send All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 26 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 10 2 Double Wiegand 26 02 double Wiegand 26 frame Same as Wiegand 26 but the Bluetooth ID is sent in 2 Wiegand 26 frame with 25 ms delay between Frame 1 The facility code and the last 2 bytes LSB of the 6 byte Bluetooth ID is sent Frame 2 The facility code and the next 2 bytes middle of the 6 byte Bluetooth ID is sent A even MSB parity bit and a odd
35. hone and set it to hidden 3 Enter the required system command on the mobile phone and click save Refer to section8 System Commands for available commands 4 Set the mobile phone to visible 5 Place mobile phone within the detection range of the system 6 Wait for 3 short beeps 7 Enter Master PIN code e g 12345678 when prompted 8 Wait for beep for successful execution of the command 9 Set the mobile phone to invisible hidden 10 Erase command from mobile phone If more commands must be executed repeat step 2 9 7 3 1 If the system doesn t respond to a command System is not in configuration mode any more 10 minutes time out Check Blue LED flashing Else re enter configuration mode Refer to section 7 2 How to enter Configuration Mode The administrator is outside the allowed configuration range of approximately 20 cm Administrator must get closer to the system The command has already been executed Try change one of the parameters or try another command The command is not valid Wrong number of parameters wrong parameter values and or wrong command length e g spaces at the end The system times out waiting to read the command or connection to mobile failed Wait for next detection All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse
36. hout PIN code and weak enter on position 5 05 0022b4b66518 0000 3 Delete User Refer to section 8 4 Delete User Command Delete user stored on position 1 enter 01 or on position 5 enter 05 3 Set the mobile phone to visible 4 Enter 4 digit access PIN code on mobile phone when prompt ID is send if correct 5 Wait for 3 short beeps which indicate that a valid command has been found and Master PIN code is required 6 Enter 8 digit Master PIN code on mobile phone when prompt acknowledge with a short beep for successful execution 7 Set the mobile phone to invisible hidden 8 Erase the command in the mobile phone For more commands repeat step 1 7 If no more commands are required Set friendly name back to desired name All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 38 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 18 4 Mobile Phone used for System Commands System Configuration Mode All mobile phones can in system configuration mode be used to enter system commands like adding and deleting users Refer to section 7 2 How to enter Configuration Mode for more details about the systems commands The system wi
37. ice Default 2 lt PIN code for user gt 4 digits 1 The privileged users administrators should be added with a access PIN code 2 The access PIN code must be entered within 15 seconds before it continues to scan for another user 3 Can be used to compensate normalize in some degree for power differences and antenna location between the used Bluetooth keys e g mobile phones fa device must be closer to the reader than most others before access is granted set parameter 3 weak device fa device gets access further away from the reader than most others set parameter 1 strong device Default is 2 standard device All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 17 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data Total length 7 digits or optional 9 digits Examples On position 1 add unique user with unknown BD address 0022b4b62918 with PIN code 1234 enter 01 1234 On position 5 add unique user with unknown BD address 0022b4b62918 without PIN code enter 05 0000 On position 1 add unique user with unknown BD address 0022b4b62918 without PIN code and strong enter 01 0000 1 On posit
38. igit master PIN code when finished All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 37 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 18 3 Mobile Phone used for Adding and Deleting Users Normal Operation The privileged users administrators on storage position 01 and 02 can add and delete users in normal operation if they are added with an access PIN code The user is first requested the normal 4 digit access PIN code Then it will prompt for the 8 digit Master PIN code if the privileged user administrator has entered a valid Add new User or Delete User command Steps 1 Enable Bluetooth on the mobile phone and set it to hidden 2 Temporarily change the Bluetooth friendly name to the desired command Examples Add User Refer to section 8 2 Add new User Command Add user with ID 0022b4b62918 and PIN code 1234 enter on position 1 01 0022b4b62918 1234 or Add user with unique ID 0022b4b62918 and without PIN code enter on position 5 05 0022b4b62918 0000 or Add user with unique ID 0022b4b62918 and with PIN code 1234 and strong enter on position 1 01 0022b4b62918 1234 1 or Add user with unique ID 0022b4b66518 and wit
39. ion 5 add unique user with unknown BD address 0022b4b62918 without PIN code and weak enter 05 0000 3 Note Any exiting user on the selected storage position will be erased l e it is not necessary to erase an existing user first System administrator should maintain a system log of users and storage positions used Please see 15 Appendix A User Log Template Caution A virtual user is by default from factory added on storage position 01 to allow easy configuration of users without first going through the normal system configuration mode The default PIN code is 1234 This corresponds to the command 01 FFFFFFFFFFFF 1234 Any user It is highly recommended to overwrite this with a specific user with a unique PIN code The virtual user can be placed on another last storage position and other PIN code to allow access for all users knowing the access PIN code Please refer to section 11 Virtual Keypad See an example in section 18 2 Adding Users to the System from factory reset Easy Enrolment All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 18 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 4 Delete User Command This comm
40. its master PIN code Buzzer input IN2 is not pulled down to GND Caution The system will not scan for detect users in configuration mode I e no Bluetooth IDs are send on the Wiegand bus All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 11 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 7 3 Howto enter System Commands Configuration Mode The system commands adding deleting users and changing system settings can be executed from any Bluetooth enabled mobile phone by temporarily changing the mobile phones friendly name After entering a command and the Master PIN code the system gives a short beep to indicate that the command has been accepted and executed and restarts the 10 minute configuration period The next command can be entered or wait for the termination of the configuration period execute the E01 command or power cycle the device to startup in normal operation Note 3 short beeps indicate when to use the Master PIN code instead of normal access PIN code Follow these steps to execute commands Steps 1 Set system into configuration mode Refer to section 7 2 How to enter Configuration Mode 2 Enable Bluetooth on mobile p
41. ive companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 16 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 3 Add new User Command Easy Enrolment Supported from firmware version 0 52 This command adds a new user to the system This is also used for editing an exiting user Make sure to store the user on the same storage position This command can only be execute in configuration mode or when the any user default is located as the privileged users administrators on storage position 01 and 02 This command will store the information together with the BD address of the mobile phone the command is read from l e you do not need to know the BD address of a mobile phone Parameters Values Description Position in system database to store the user 2 digits 01 02 Privileged users administrators 01 02 03 07 Normal users GC501 03 07 Sarane pee 03 12 Normal users GC502 03 12 03 22 Normal users GC503 03 22 03 52 Normal users GC504 03 52 Ex position 1 is written as 01 User access PIN code Ex 1234 Use 0000 to disables use of access PIN code for that particular user Device power class lt power class gt 1 strong device 2 standard device optional not required 3 weak dev
42. ll prompt for the 8 digit Master PIN code if a valid system command is found Steps 1 Set system into configuration mode by pulling the buzzer input IN2 to GND Refer to section 7 2 How to enter Configuration Mode for more details 2 Enable Bluetooth on the mobile phone and set it to hidden 3 Temporarily change the Bluetooth friendly name to the desired command Examples Change Master PIN Refer to section 7 2 How to enter Configuration Mode Change Master PIN to 12345678 enter 12345678 Add User Refer to section 8 2 Add new User Command Add user with unique ID 0022b4b62918 and with PIN code 1234 enter on position 1 01 0022b4b62918 1234 or Add user with unknown ID and without PIN code enter and weak on position 5 05 0000 3 Enter the command on the users mobile phone Delete User Refer to section 8 4 Delete User Command Delete user stored on position 1 enter 01 or on position 5 enter 05 Change Wiegand type Refer to section 8 5 Change System Configuration Command 1 Facility code is 32 0x20 and Wiegand type is changed to standard Wiegand 26 enter 20 01 Change Detection Range Refer to section 8 6 Change System Configuration Command 2 Advanced settings Select power range 2 lt 10 m and approximately 5 m with input 1 and 2 active at low level GND and output 1 and 2 with high level enter 2 6 50 0 0 1 1 4 Set the mobile phone to visible 5 Place mobile phone within the detection r
43. must be power cycled for changes to take effect The System settings can be reset to factory value Please see section 14 Default Factory System Settings Please see section 13 Access Detection Range for some typical values for lt power range gt lt TX power level gt and lt Detection range gt and how to adjust detection range System administrator should maintain a system log with System Settings 2 for Normal Operation Mode Please see 17 Appendix C System Configuration Log Template All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 22 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 8 7 Execute System Command Advanced settings Supported from firmware version 0 52 This section describes some predefined system commands for easy execution from the administrator mobile or from any mobile phone when in configuration mode Caution Caution must be taken when using these system commands Command Values Description Performs a System Reset Performs a Factory Reset refer to section 14 1 System enters Configuration Mode Eog sde Performs a Factory Reset and enters 8 Configuration Mode E02 E03 Erases the complete
44. omatically prompt the user for the Master PIN code The Master PIN code is a system code for authenticating the user system administrator Caution The default Master PIN code should be changed before use of the system The Master PIN code should only be known by a system administrator or a limited number of people to avoid unauthorized use Parameters Values Description The Master PIN code for adding removing users lt New Master PIN code for igit nd change system settings the system gt 8 digits mo me Default 12345678 Total length 8 digits Example To change Master PIN to 12345678 enter 12345678 Note The present old Master PIN code must be entered on the mobile to enable the new Master PIN code The Master PIN code can be reset to factory value Please see section 14 Default Factory System Settings System administrator should store the new master PIN code in a system log Please see 16 Appendix B System Master PIN Code The Master PIN code must be entered and accepted within 15 seconds before it continues to scan for another user All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 Allrights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 14 40 AccessZone GC400 Series GC401 GC4
45. ons without notice and shall have no obligation to update the information contained in this manual MVC Data ApS s products are not authorized for use as system critical components in life supporting devices or systems AccessZone is a registered trademark of MVC Data ApS The Bluetooth trademark is owned by the Bluetooth SIG All other trademarks are owned by their respective owners The displayed screens may differ and depends on the mobile phone used for configuration Copyright 2005 2011 MVC Data ApS All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 5 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 2 Introduction The AccessZone GC400 series GC401 GC404 are Wiegand Bluetooth ID Readers They are well suited for use in private homes shops and companies Since they have Wiegand output they can be used with all access control systems with Wiegand bus They are unique wireless Bluetooth Readers with the latest Bluetooth technology a wireless technology that operates in the license free ISM band at 2 4 GHz The reader sends the Bluetooth ID on the Wiegand bus for verification in a central access control system No validation is done in the
46. or Default 1 NOT USED Note Input 3 and input 4 are by default low active 0 GND and cannot be changed 1 The figure show the relation between TX and RX A mobile phone must be within the RX green zone and TX should ideally be on RX or a little longer Mobile phone is a NOT detected Mobile phone ID is read and send A mobile phone between TX and RX is detected but ID is not send All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 84 02 21 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data Total length 14 digits Example To select power range 2 lt 10 m and approximately 0 5 m with input 1 and 2 active at low level GND and output 1 and 2 with high level enter 2 6 50 0 0 1 1 There is a close relation between parameters lt power range gt lt TX power level gt and lt Detection range gt The system detection range depends on selected lt power range gt lt TX power level gt Shortest detection range is with lt power range gt 1 lt TX power level gt 1 and lt Detection range gt 0 Longest detection range is with lt power range gt 3 lt TX power level gt 8 and lt Detection range gt 99 System
47. plementation details for a particular mobile phone All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 31 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 12 2 GPS Key as Key A Bluetooth GPS antenna is also suitable as a simple wireless key It works fine with and without PIN code The PIN is typically fixed to 0000 or 1234 so the PIN code can typically be left out The GPS antenna can typically not have an active connection to another Bluetooth device to be detectable visible Note PIN 0000 means no PIN code in the GC400 system Some battery powered devices will automatically switch off after e g 60 minutes to preserve battery power Please refer to the GPS user manual for more details 12 3 AccessZone Bluetooth Tags The AccessZone Bluetooth Tags is very suitable as a simple wireless key They work without PIN code They are available as battery powered hand held devices or as power wired devices for mounting on cars trucks or wheelchairs Please refer to user manuals for more information All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29
48. ppendix A User Log Template Caution A virtual any user is by default from factory added at storage position 01 a privileged user to allow an easy first time configuration of users without going through the normal system configuration mode PIN code 1234 is used This corresponds to the command 01 FFFFFFFFFFFF 1234 Bluetooth ID reader with unique users with PIN code It is highly recommended to overwrite this with a specific user with a unique PIN code and move the any default user to the last location used In example move any user to the last storage position 7 GC401 Execute command 07 FFFFFFFFFFFF Q000 The privileged users devices added on position 01 or 02 can be used to add other users and the any user on position 07 will allow the system to send all other Bluetooth IDs on the Wiegand bus Simple Bluetooth ID reader Add the any user without PIN code on storage position 03 if PIN code is not used Delete position 01 and 02 if no privileged users 01 and 02 are required The Bluetooth reader will now send all the detected Bluetooth IDs on the Wiegand bus Execute command 03 FFFFFFFFFFFF 0000 Refer to section 11 Virtual Keypad for more details Note With user 01 and 02 delete you need to enter Configuration Mode to be able to add users again All information is subject to change without notice All other products and brand names are registered trademarks of their respect
49. pyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 7 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 4 System Overview This section presents a system overview with an I O description Input 2 IN2 External Buzzer Output 1 OC1 Wiegand DataO DO Input 3 IN3 External Red LED Output 2 OC2 Wiegand Data1 D1 Input 4 IN4 External Green LED 5 1 O Description GC400 series have 3 inputs and 2 outputs The active levels high 1 low 0 when an action is performed can be configured inverted for some inputs outputs Please refer to section 8 6 Change System Configuration Command 2 Advanced settings for more details 5 1 Inputs Input 1 IN1 Not used Input 2 IN2 External control of buzzer entering configuration mode during power up Input 3 IN3 External control of Red dual LED in the middle Input 4 IN4 External control of Green dual LED to the right 5 2 Outputs Open collector type 500mA Output 1 OC1 Wiegand DataO DO output for external access controller Output 2 OC2 Wiegand Data1 D1 output for external access controller Please see the GC400 series Installation Manual for instructions on how to install the system All information is subject to change without notice All other products and brand names are registered tradem
50. rademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 25 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 10 Wiegand Types The GC400 series supports 10 different Wiegand frame formats The Wiegand access controller must support at least one of the supported Wiegand formats GC400 uses the Wiegand signalling and different frame data formats The data is send on the Wiegand bus l e a 0 is send on line DataO and a 1 is send on line Data1 The signals are held at logical high levels until the data is sent GC400 places the data as asynchronous low going pulses on the Data0 or Data1 lines to transmit the data to the access control system The Wiegand specification requires a pulse width time between 20 us and 100 us and a pulse interval time between 200 us and 20ms GC400 uses a pulse width of 50 us and a pulse interval time of 2 ms A 8 bit facility code and Bluetooth ID lengths between 16 48 bit are used depending on the selected Wiegand type Frame format 1 bit 8 bit 16 48 bit 1 bit MSB even parity Facility code of Bluetooth ID LSB odd parity Caution Mathematically it only gives a total of 256 different 0 to 255 facility codes The shortest Wiegand format Wiegand 26 only uses the lowest 16 bit of the Bluetooth ID number w
51. saniassaiserdvounasascuaapatadssaatiaanadnorasanmeanuea eteki 20 8 6 Change System Configuration Command 2 Advanced Settings ccccssscccessssteceeeeeeeeeeees 21 8 7 Execute System Command Advanced SQtuin eS sicccsicsassniscsctoiieassaseidewasanesnausnceeteabeolebialesmeainns 23 8 8 Execute System Configuration Advanced SOtrIN GS sisicisaccssgasccsassassescaasncscedssnseesndgastncasenesennnd 24 9 How to unde rstand TX and RX Parameter Sipsscsesaiusiesatndsdenan caansaacsctannsupaiaxeancssaunspaciamavedeiawoacaemanseends 25 1O Wecana TYDE Siiran a aaa ae 26 10 1 Wiegand 26 cccccesssececeescessessesaeeeceeeesceesesseeeeeeesceesesaeseeeeeescesesaeeeaeseeeeeeseeeeeeeeeeeseauaaaaseeeeess 26 10 2 Double Wiegand 2 6niuinsnennnnnan nnan a aia 27 10 3 Triple Wiegand 26 srasni arane R AORO 27 10A Wiegand SMneninerannen mne n tbl Son cas a anaes races T N 27 105 Wiecand A2 oan N E E E eed eeeeseenaeenes 28 10 6 Wiegand BOrsincninnynicinna a iaaa 28 10 7 Wiegand 58inci e E E E E A AA 28 10 8 Wiegand 40 With XOR Checks Wiems snninnunian a Aaaa 28 10 9 Wiegand 56 with XOR checkSUM sssssssessessssersssssrrssrrtrsrtrtrtestentsstennsstetssrtttentertentserennssrennt 29 10 10 Wiegand 64 with XOR ChecCkS Mieisnsrincininicnsinenmne oneei 29 11 Virtual Keypad zensten a a A aR TARA 30 11 1 Virtual Keypad INNO a ncseacsolrantancanatdnedaapsiomasuasd idaasaucantaiawssbedntnsdeecanentalnaneshaetontiacauerenssunaat 30 11 2 Virtual Keypad Mixed
52. to be added The system administrator adds a user with the special BD address FFFFFFFFFFFF not a valid BD address and a 4 digit access PIN code on storage position 03 Refer to section 8 2 Add new User Command The system will in this mode send the Bluetooth ID on the Wiegand bus for all users who enter the correct 4 digit access PIN code The request for PIN code is disabled when 0000 is entered as PIN code and thereby send all Bluetooth ID number on the Wiegand bus l e a simple Bluetooth ID reader The system administrator can at any time change the PIN code Caution If this special user is placed on storage position 01 or 02 all users will have the ability to add and delete users privileged user if they know the correct access PIN code and the Master PIN code This is not recommended 11 2 Virtual Keypad Mixed Mode The system can be configured to be a mixed mode virtual keypad with up to 4 9 19 or 49 unique users and 2 privileged number depends on purchased system version and a virtual keypad user with the special BD address FFFFFFFFFFFF not a valid BD address and optional a 4 digit access PIN code The system will in this mode send the Bluetooth ID for all unique users after entering of their unique 4 digit access PIN code no PIN code and the Bluetooth ID for all other users which enter the correct 4 digit virtual keypad access PIN code This feature allows the virtual keypad PIN code to be changed frequ
53. tooth enabled mobile phone strongly depends on implementation details for a particular mobile phone Radio noise from other radio communication in the 2400 2483 5 MHz ISM frequency band e g WI FI access points and other Bluetooth activity etc can course disturbances of the radio signals to from the Bluetooth transceiver and consequently increase the detection time Metal surfaces in the vicinity can also course disturbances distortion or prevent radiation of the radio signals to and from the Bluetooth transceiver How the mobile phone device is held in the hand may have an significant impact on the radio signals to and from the Bluetooth transceiver 12 1 Mobile Phone as Key Any Bluetooth enabled mobile phone can be used as access key No software has to be installed on the mobile phone The system will detect the mobile phone when it comes within the specified detection range TIP A few mobile phones cannot handle an active pairing or search for devices at the same time Steps 1 Enable Bluetooth on mobile phone and set it to visible Refer to the mobile phone s User Manual 2 Enter the 4 digit access PIN code when prompt If PIN code is required Note The time Bluetooth inquiry scan time a mobile phone uses to scan for other Bluetooth devices that want to connect to it is typically set to a low value to preserve battery power l e the time to discover a nearby Bluetooth enabled mobile phone strongly depends on im
54. transmitting power TX The next parameter 1 2 40 0 0 1 1 corresponds to the received signal strength RX The parameters can also be set with the configuration commands in section 8 8 Execute System Configuration Advanced settings Here are some example commands to start with Range Distance System Command Very short range 1 2 30 0 0 1 1 1 4 50 0 0 1 1 2 3 60 0 0 1 1 2 8 80 0 0 1 Very long range 3 8 99 0 0 1 1 Note The values 1 2 40 0 0 1 1 in bold must match your requirements The default values are used in these examples Please refer to 8 6 Change System Configuration Command 2 Advanced settings for more details Please follow the descriptions in section 13 2 Detection range is to short and 13 3 Detection range is too long for adjusting to desired detection range up or down All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2011 01 29 US 1 06 Copyright 2005 2011 All rights reserved MVC Data ApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mailinfo mvc data com Phone 45 25 12 8402 33 40 AccessZone GC400 Series GC401 GC404 User Manual MVC Data 13 2 Detection range is to short Follow and repeat these steps or use system command E06 to increment the detection range Increase 3 the lt Detection range gt value If lt Detection range gt 99 is not

Download Pdf Manuals

image

Related Search

Related Contents

Vorwort alte Pik I.fm  ATL + IP - Leucotron  Structured Funds User Manual  Palm Tungsten E Handbook  User Manual    ASUS I7825 User's Manual  Complete Owner`s and Service Manual for the Universal  GUIDA PER L`UTENTE - Motorola Monitors & Cordless Phone North  Trouble Shooting Guide  

Copyright © All rights reserved.