Home
Instruction Manual
Contents
1. 0ceeeeee eee e eee 15 18 Return Authorizations 0 e cece e eee eee ee 19 CC20 Approval Label Bullard CC20 Approval Label os SERVICES bal j Type C Continuous Flow Supplied Air Respirator 2 C This respirator is approved only in the following configurations RESPIRATOR ALTERNATE BREATHING TC PROTECTION MODEL ALTERNATE SUSPENSION TUBE ALTERNATE FLOW CONTROL DEVICE HOOD HARD HAT cc20 PARZ o alu w ziz rz z a be SSISIASSSBSSsisisisSassle noobs 22 SCE SE SSeS sss S lgelsaalselelssalselesslesieses sees sseeesseees aSgeasajsiada ds sees se Z RRISIRRIRR RRRS S KRAG S R EE Ee Fess gag Ssisgsgsisgs 19C 154 SA CF CC20 XIXI XIXI XIXI XIXIXIXIXIXIX X XIX X X I XIXIXIXIXIXIXIXIXIXIXIXIXIXIXIXIXIXIXI XI XIXIXIXI XI XIXIXIXI XIX IXIXIXIX Protection CF Continuous Flow SA Supplied Air Cautions and Limitations A Not for use in atmospheres containing less than 19 5 oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards D Airline respirators can be used only when respirators are supplied with respirable air meeting the requirements of CGA G 7 1 Grade D or higher quality E Use only the
2. Other Available Flow Control Assemblies without breathing tube for CC20 Series Airline Respirators Adjustable Flow disconnect fittings F40 4 Industrial Interchange 52532 25 7 6m with 1 4 Snap Tite steel fittings F40B 4 Industrial Interchange Brass V52535BLACK 25 7 6m with 1 2 Industrial Interchange F40S 4 Industrial Interchange Stainless Steel brass fittings F41 4 Schrader V55035BLACK 50 15 2m with 1 2 Industrial Interchange F42 4 Snap Tite steel brass fittings F43 4 Snap Tite brass V20 Series Hoses ae ye or stainless steel For use with Bullard Free Air Pumps Include 1 2 I D rubber hose with 1 2 Industrial Interchange Constant Flow 7 Hansen compatible female quick disconnect coupler and F30 a Industrial Interchange 1 2 male quick disconnect nipple F30B 4 Industrial Interchange Brass F30S 4 Industrial Interchange Stainless Steel V2050ST 50 15 2 m F31 4 Schrader V20100ST 100 30 5 m F32 4 Snap Tite steel Quick Disconnect Nipples Couplers and Adapters F33 4 Snap Tite brass For use with V10 hoses only F34 4 Snap Tite stainless steel Nipples F35 2 Industrial Interchange 1 4 Industrial Interchange Hansen compatible F37 4 Cejn S9841 With 1 4 Female NPT F35B 2 Industrial Interchange Brass V17 With 3 8 Female NPT F35S 2 Industrial Interchange Stainless Steel Adjustable Cool Tubes Cold Only Hot Cold Dual Cool Coupling Type AC100030 HC240030 DC5040 1 4 Industrial
3. Airline respirators can be used only when respirators are supplied with respirable air meeting the requirements of CGA G 7 1 Grade D or higher quality E Use only the pressure ranges and hose lengths specified in the instruction manual J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance of these respirators S Special or critical Users Instructions and or specific use limitations apply Refer to User s Instructions before donning Operations Protection Respiratory The CC20 respirator is NIOSH approved TC 19C 154 as a Type C continuous flow supplied air respirator It can be worn for general purpose applications including pharmaceutical manufacturing chemical and pesticide handling tank cleaning spray painting and other industrial or agricultural applications in which hazardous compounds are present The CC20 respirators are not approved for use in any atmosphere immediately dangerous to life or health IDLH or from which the wearer cannot escape without the aid of the respirator IDLH is defined in 29 CFR 19
4. Interchange 1 4 Snap Tite steel AC100030B HC240030B DC5040B 1 4 Industrial Interchange Brass 1 4 Snap Tite brass AC100030S HC240030S DC5040S 1 4 Industrial Interchange Stainless Steel 1 4 Snap Tite AC100031 HC240031 DC5041 1 4 Schrader stainless steel AC100032 HC240032 DC5042 1 4 Cejn AC100033 HC240033 DC5043 AC100034 HC240034 DC5044 AC100037 HC240037 DC5047 AC100035B HC240035B N FRIGITRON2000 v5 Coiled Hose FRIGITRONZOOOR 4696 46913 46915 V52530 V55030 V52531 FRIGITRON2000S 5454 5457 5458 V55031 V52532 V55032 V2050ST V20100ST V52535BLACK V55035BLACK CC20 Series Airline Respirator User Manual Return Authorization The following steps must be completed before Bullard will accept any returned goods Please read carefully Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs 1 Contact Bullard Technical Support by telephone or in writing at Bullard 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Phone 859 234 6616 In your correspondence or conversation with Technical Support describe the problem as completely as possible For your convenience your technical support specialist will try to help you correct the problem over the phone 2 Verify with your technical support specialist that the product should be returned to Bullard Technical Support will provide you with written permission and a return authorization
5. air supply hose sjuawaiinbay sry Huryze ig G Breathing Air Pressure Table Bullard CC20 Breathing Air Pressure Table This table defines the air pressure ranges necessary to provide CC20 Series respirators with a volume of air that falls within the required range of 6 15 cfm or 170 425 Ipm according to U S Government regulations 42 CF R Part 84 Subpart J 84 150 Table 8 1 2 3 4 5 6 Flow Control Valve Air Supply Air Supply Maximum Required Air Source Climate Control Device Hose Hose Length Number of Pressure Range feet Hose Sections psig air Stationary F30 F30B F30S F31 F32 v10 25 1 14 15 or Portable F33 F34 F37 50 2 15 18 Air Compressor 100 3 19 24 150 4 23 29 200 5 25 34 250 300 5 31 39 F35 F35B v5 25 1 12 18 50 2 19 23 F40 F40B F40S F41 F42 v10 25 1 22 25 F43 F44 F47 50 2 24 27 100 3 27 32 150 4 30 37 200 5 33 40 250 300 5 38 45 v5 25 1 22 26 50 2 25 30 AC100030 AC100030B v10 25 50 2 55 65 AC100030S AC100031 75 150 3 60 70 AC100032 AC100033 175 300 5 65 75 AC100034 AC100035B AC100037 V5 25 1 55 65 50 1 56 69 DC5040 DC5040B DC5040S v10 50 2 48 52 DC5041 DC5042 DC5043 100 3 59 63 DC5044 DC5047 150 3 68 72 200 3 80 84 250 3 85 92 300 5 90 98 V5 25 1 53 57 50 2 67 71 HC240030 HC240030B v10 25 1 59 61 HC240030S HC240031 50 2 63 65 HC240032 HC240033 100 3 68 70 HC240034 HC240035B 150 4 73 75 HC240037 200 4 77 79 250 5 80 82 300 5 8
6. is supplied from a breathing tube connected to the back of the hood CC20 Series Airline Respirator User Manual Type C Continuous Flow Class Approval No TC 19C 154 CC20 Series respirators are compatible with breathing air sources such as breathing air compressors or Bullard Free Air Pumps Bullard offers the appropriate approved breathing tube flow control device and air supply hose to connect the CC20 Series respirator to these breathing air sources CC20 Series respirators are approved by NIOSH for use with optional Bullard climate control devices Contact Bullard or its local authorized distributor for more information about these and other accessories for CC20 Series respirators All Bullard parts must be present and properly assembled to constitute a NIOSH approved respirator For technical assistance contact Bullard Technical Support at 877 BULLARD 285 5273 or 859 234 6616 NOTE Bullard CC20 hoods are also NIOSH approved for certain PAPR configurations Please refer to your Bullard PAPR manual or call Customer Service at 877 BULLARD 285 5273 Save this manual for future reference injury A WARNING Read all instructions and warnings before using these respirators Failure to follow these instructions could result in death or serious injury The CC20 Series Airline Respirators are not approved for abrasive blasting The CC20 respirator s air source must supply clean breathable air Grade D or
7. number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products suspected to be contaminated will be professionally discarded at the customer s expense 4 Ship returned products including those under warranty with all transportation charges pre paid Bullard cannot accept returned goods on a freight collect basis 5 Returned products will be inspected upon return to the Bullard facility Bullard Technical Support will telephone you with a quote for required repair work which is not covered by warranty If the cost of repairs exceeds stated quote by more than 20 your technical support specialist will call you for authorization to complete repairs After repairs are completed and the goods have been returned to you Bullard will invoice you for actual work performed A UoeZHoy ny UIng y Bullard Bullard 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany phone 0049 2642 999980 fax 0049 2642 9999829 www bullardextrem com Bullard Asia Pacific Pte Ltd Cisco Centre 20 Jalan Afifi 08 03 Singapore 409179 Tel 65 6745 0556 Fax 65 6745 5176
8. of CC20 Series Series respirators 10 DO NOT connect the respirators air supply hose to nitrogen oxygen toxic or inert gases To prevent this airline couplings used for this respirator shall be incompatible with outlets for other gas systems Failure to connect to the proper air source could result in death or serious injury Be certain your employer has determined that the breathing air source provides at least Grade D breathable air 11 DO NOT use these respirators in poorly ventilated areas areas where oxygen is less than 19 5 or in confined spaces such as tanks small rooms tunnels or vessels unless the confined space is well ventilated and contaminant concentrations are below the upper limit recommended for this respirator The procedures for confined space entry operation and exit are defined in applicable regulations and standards including 29 CFR 1910 146 12 DO NOT use these respirators for abrasive blasting or underwater diving 13 DO NOT reach your hand into the hood head cover in atmospheres containing air contaminants Leave the contaminated area and clean hands before reaching inside the hood B Butusem o Operations Bullard Cautions amp Limitations For CC20 Airline Respirators A Not for use in atmospheres containing less than 19 5 oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards D
9. of protection originally provided Use only CC20 components and replacement parts manufactured by Bullard and approved by NIOSH for use with these respirators Since respirator use and the quality of maintenance performed vary with each job site it is impossible to provide a specific time frame for respirator replacement Inspect all components of this respirator system during cleaning and before and after each use for signs of wear tear or damage that might reduce the degree of protection originally provided Respirators used by more than one person must be cleaned inspected and sanitized after each use If not cleaned contamination may cause illness or disease WARNING The air you breathe will not be clean unless the respirator you wear is clean Failure to heed this warning could result in death or serious injury CC20 Series Airline Respirator Hood and Headband Suspension Inspection Inspect the hood material for rips tears or damage from excessive wear that might reduce the degree of protection originally provided Inspect the inner neck cuff for elasticity The respirator s plastic lens should be inspected for cracks scratches or any other signs of damage Disassemble the breathing tube from the hood by removing the nylon hose clamp To remove the hose clamp slide the locks sideways in opposite directions Remove the headband suspension and optional chin strap from the hood except on loose fittin
10. pressure ranges and hose lengths specified in the instruction manual J Failure to properly use and maintain this product could result in death or serious injury CC20 Series Airline Respirator User Manual Bullard m Cynthiana KY 41031 USA 1 800 827 0423 COMPONENTS AIR HOSE ACCESSORIES CAUTIONS AND LIMITATIONS alu uju E 2 EE 5s 8 oO alo O x x ees Q z Zlo G ira 5 aln ass gt a gt 32 ulsa nS BSE ele 5 5 2 el 2 amp z z W H a 3S SSFP VITBAS Fa qalsls ol SASS SSIS eS TENS al oly 22 AAA TS scala Bola Aa SBA aS H 4 dal s3 ele 3 3 S S S S S 9 5 FA AAs asgosags SIAN S a alal al al S S S Al S al a m tA S 8 8 S S S S t t S t E Se Z SSS ASASSSASS SSS SegqeosssssyAaasqas SSSA 4gsaFeasaga da sag aaa siVsgssags SA SSS S888 B ee AA 4 F449 BO FSi 4 VSS SSSss SSTT aoa ss TF aLa Saaga g S e e a o a gea A S g Afu 3 8 8322 35 55 B S e Sa EE ga SS S858222 3RR Rsa Ea Sl D pal F S S o gt gt 0 LA a oe SIS g a 1 gt gt a gt XEX X X XEXEX XEX X X EX X EX X XEX X EX EX EX X EX X IX IX X PRIX IR IX XIX IR X IX X PRIX X X X X IR IX X RIX IX X X PRIX X X X PX IR X X X X X X X ABCDEJMNOS M All approved respirators shall be selected fit
11. the air remains contaminant free Always use an inlet filter on your air source Use suitable after cooler dryers with filters and carbon monoxide monitors and alarms like the Bullard Series of CO monitors and filters as necessary The air should be regularly sampled to be sure that it meets Grade D requirements CC20 Series Airline Respirator CC20 Breathing Air Pressure Air pressure should be monitored at the point of attachment while operating this respirator A reliable air pressure gauge must be present to permit you to monitor pressure during actual respirator operation A WARNING Failure to supply the minimum required pressure at the point of attachment for your hose length and CC20 respirator type will reduce airflow and could result in death or serious injury Special or Critical User s Instructions The Breathing Air Pressure Table see page 8 defines the air pressure ranges necessary to provide CC20 Series respirators with a volume of air that falls within the required range of 6 15 cfm or 170 425 Ipm Ref 42 CFR Part 84 Subpart J 84 150 Make sure you understand the information in the Breathing Air Pressure Table before using this respirator m Determine the type of air source you are using Column 1 then find your flow control valve climate control device Column 2 2 Be sure your Bullard air supply hose Column 3 is approved for use with your flow control valve climate control dev
12. 0 F34 F40 F42 AC100030 AC100034 DC5040 DC5042 HC240030 HC240033 R F30B F35 F40B F43 AC100030B AC100035B DC5040B DC5043 HC240030B HC240034 T F30S F35B F40S F44 AC100030S AC100037 DC5040S DC5044 HC240030S HC240035B F31 F35S F4l F47 AC100031 Frigitron 2000 DC5041 DC5047 HC240031 HC240037 A F32 F37 AC100032 Frigitron 2000B HC240032 i F33 AC100033 Frigitron 2000S All flow control devices require the 20BT breathing tube to constitute complete breathing tube assemblies Breathing tube must be purchased separately Air Supply Hose Connects breathing tube to air source supplying clean breathable air Hose for High Pressure Hose for Low Pressure Compressed Air Source Ambient Air Pump V5 v10 v20 3 8 Coiled I D Hose 3 8 I D Hose 1 2 I D Hose V5 Starter Extension Hose 469 Starter Hose V20 Starter Extension Hose 545 Extension Hose Available in 25 and 50 foot lengths with Available in 25 50 and 100 foot lengths Available in 50 and 100 foot lengths with 1 2 a variety of 1 4 and 1 2 quick with a variety of 1 4 quick disconnect quick disconnect Industrial Interchange disconnect fitting styles and materials fitting styles and materials See parts list fittings See parts list page 18 for details See parts list page 18 for details page 18 for details CC20 Series Airline Respirator User Manual A WARNING Failure to heed these warnings could result in death or serious injury 1 Improper
13. 00 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple HC240031 With 1 4 Schrader steel quick disconnect nipple HC240032 With 1 4 Snap Tite steel quick disconnect nipple CEG DC5040 ig Dual Cool Bh HC2400 Series CC20 Series Airline Respirator User Manual CATALOG NUMBER DESCRIPTION Dual CooL Climate Control Device DC5040 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple Includes CH60 connector hose and nylon belt Order vest separately DC70M L Medium Large cooling vest DC7OXL XXL Extra Large XX Large cooling vest Replacement Parts for Climate Control Assemblies MV2400 Muffler valve assembly for HC2400 CH60 Connector hose for use with DC5040 Climate Control Assembly For use with Bullard EDP30 or ADP20 Free Air Pump Cool Tube Adjustable Flow Frigitron 2000 With 1 2 Industrial Interchange steel Hansen compatible quick disconnect nipple DC70M L DC7OXL XXL CH60 AC1000 Series a uo ewozug Huuapig l Ordering Information Bullard Air Supply Hoses and Fittings for CC20 Series Airline Respirators V10 Series Starter Hose Kits For use with Breathing Air Compressors Include 25 7 6m 3 8 I D rubber hose with 1 4 female quick disconnect coupler and V13 adapter fitting 3 8 hose to 3 8 pipe 4696 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect coupler 46913 With 1 4 S
14. 10 134 b Head CC20 Series respirator hoods with the 20TG or 20RT headband suspension DO NOT provide head protection If head protection is required order the 20TICH or 20SICH model The 20TICH and 20SICH hoods when used with a Bullard model 51 or 3000 hard hat meet ANSI Standard Z89 1 2003 Type I Classes E amp G requirements for protective headwear for industrial workers These hard hats are designed to provide limited head protection by reducing the force of falling objects striking the top of the hard hat shell Face The 20TICH and 20SICH models meet ANSI Z87 1 2003 impact and penetration requirements for face protection The 0 040 acetate lens provides limited face protection from flying particles or spray of hazardous liquids but is not shatterproof Eyes CC20 Series respirators DO NOT provide eye protection Wear approved safety glasses or goggles at all times Ears CC20 Series respirators DO NOT provide hearing protection Use properly fitted earmuffs earplugs or other protection when exposed to high noise levels CC20 Breathing Air Requirements Air Quality WARNING The CC20 respirator must be supplied with clean breathable air Grade D or better at all times This respirator does NOT purify or filter out contaminants Failure to heed these warnings could result in death or serious injury Respirable breathable air must be supplied to the point of attachment of the approved Bullard air supply hos
15. 4 86 v5 25 1 65 66 50 1 68 69 Bullard F35 F35B F35S v20 50 1 4 6 Free Air 100 2 6 8 Pumps 200 2 10 15 300 3 13 18 Frigitron 2000 v20 50 1 16 22 Frigitron 2000B 100 2 18 25 Frigitron 2000S 200 2 22 30 300 3 25 34 CC20 Respirator Assembly Adjusting and Installing Headband Suspension in Hood If using 20TICH or SICH models see page 10 1 Size the standard 20TG headband suspension by squeezing top and bottom edges of rear buckle with your thumb and forefinger Decrease size of headband suspension by sliding band through buckle 2 Squeeze the buckle to disengage sizing mechanism and place headband suspension on your head Continue squeezing buckle while pulling headband suspension down over your head Headband suspension automatically adjusts to your size and locks when you release your grip see Figure 4 Headband suspension should feel comfortable and snug Figure 4 Tf using the optional 20RT ratchet headband suspension refer to the instruction sheet provided with the 20RT Sizing 20RT Ratchet Headband Suspension Working from inside hood turn ratchet knob until headband suspension is at its largest size Place hood on your head and adjust ratchet knob from outside the hood to a comfortable fit An optional chin strap is available for additional comfort and stability 3 Remove tissue paper from plastic lens of respirator hood 4 With clear lens facing you insert headband suspension in
16. Bullard TREFFIT AFT k Bullard CC20 Respiratory Systems provide a continuous flow of air from a remote air source via airline The flow of air is delivered to the respirator wearer through a patented air delivery system CC20 Series respirators offer protection from airborne contaminants that are not immediately dangerous to life or health IDLH or that do not exceed concentrations allowed by applicable OSHA MSHA EPA NIOSH or ACGIH regulations and recommendations or any other applicable regulations for continuous flow airline respirators CC20 Series airline respirators are approved by NIOSH TC 19C 154 Type C Bullard has determined that these respirators may be used to provide respiratory protection in general purpose applications including pharmaceutical manufacturing chemical and pesticide handling tank cleaning spray painting and other industrial or agricultural applications in which hazardous compounds are present Bullard hoods are available in 12 different styles and sizes including a loose fitting facepiece style with a partial facial seal Bullard hoods will accommodate limited facial hair without compromising the level of protection Facial hair must not interfere with or protrude under the facial seal on the 20LFL and 20LFM hoods The hood covers are held in place by snap in replaceable suspensions or in the case of the loose fitting facepiece hoods a sewn in elastic suspension Breathing air
17. C20 Series respirator assemble the respirator using the instructions given on pages 9 11 1 Connect NIOSH approved Bullard air supply hose to an air source supplying Grade D breathable air as defined on page 7 Turn on breathing air source 2 With air flowing connect breathing tube assembly to air supply hose see Figure 16 Connect quick disconnect fitting on breathing tube assembly to quick disconnect coupler on air supply hose Once fitting is secured release coupling sleeve to lock fittings together Pull on both hoses to make sure they are attached securely Figure 16 3 Adjust air pressure at point of attachment to within the approved pressure range see Figure 17 See the Breathing Air Pressure Table page 8 for approved pressure ranges Pressure Gauge Point of Attachment Respirator lt a f A Air Supply Hose Grade D Breathable Air Source Figure 17 4 With air still flowing put on CC20 Series respirator hood pi Position headband suspension or hard hat for a comfortable fit See instructions on page 9 for proper sizing 6 If using an optional chin strap pull elastic strap under your chin Adjust for a secure and comfortable fit N Tf using the Bullard loose fitting facepiece hoods Available in 20LFM medium head sizes 6 1 2 to 7 and 20LFL large head sizes 7 1 8 to 8 Select the size that fits most comfortably and matches your head size Remove the protective cover from the visor
18. Pull the hood over your head and adjust the headband around your head and the elasticized edge of the faceseal under your chin Make sure that the breathing tube is not twisted after donning 8 Tuck inner bib of hood except on 20TJ 20LFM and 20LFL into shirt or protective clothing for additional splash and overspray protection see Figure 18 Figure 18 9 Pull respirator outer bib over collar of shirt or protective clothing If you are using the 20SIC 20SICH or 20TICH model pull the long outer bib down on the outside of clothing and tie at the sides 10 With breathing tube assembly attached to the hood fasten belt at waist or hip level and adjust for comfort 11 Recheck air pressure and adjust if necessary 12 With air flowing into your respirator you are now ready to enter work area Removing the CC20 Respirator When finished working leave work area wearing respirator and with air still flowing Once outside contaminated area remove respirator and then disconnect the air supply hose using the quick disconnect fittings NOTE If using V20 Series 1 2 I D air supply hose the hose quick disconnect coupler does not have a shut off valve Therefore air will continue to flow freely after disconnecting hose from respirator Inspection Cleaning and Storage A WARNING Failure to heed these instructions could result in death or serious injury LEAVE WORK AREA IMMEDIATELY IF Any respirator componen
19. SICH not included Hood with inner bib and long outer bib for use with headband suspension 20TICS Tychem QC with taped and sealed seams and 20TG headband suspension 20TICSN Tychem QC with taped and sealed seams no headband suspension 20SIC Tychem SL with taped and sealed seams and 20TG headband suspension 20SICN Tychem SL with taped and sealed seams no headband suspension 20LFM Tychem QC facial seal sewn in suspension small 20LFL Tychem QC facial seal sewn in suspension large Accessory Items for All Hoods 20LC Mylar lens covers 25 pkg 20LCL Mylar lens covers 25 pkg Headband Suspensions and Hard Hats 20TG Standard headband suspension 20RT Sure Lock ratchet headband suspension 3000 Hard hat with standard suspension white 3000R Hard hat with ratchet suspension white 51WHP Hard hat with standard suspension white 51WHR Hard hat with ratchet suspension white Accessories for Headband Suspension and Hard Hats ESULTRA Standard replacement suspension for 3000 hard hat ESRTSL Replacement ratchet suspension for 3000R hard hat RS4PC Standard replacement suspension for 51WHP hard hat RS4RC Replacement ratchet suspension for 51WHR hard hat 20NC Chin strap for 20TG and 20RT headband suspension ES42 Chin strap for 3000 and 5100 hard hats ES42 3000 51WHP 51WHR a uolzeWojuT BuLiapic B Ordering Information Bullard CATALOG NUMBER DESCRIPTION Breathing Tubes 20BT Breathing tu
20. aled seams with inner bib long outer bib and headband suspension 20SICH Tychem SL hood with taped and sealed seams with inner bib and long outer bib for use with head protection 20LFM ychem QC loose fitting facepiece hood facial seal sewn in suspension lightweight breathig tube small medium head sizes 6 2 7 20LFL Tychem QC loose fitting facepiece hood facial seal sewn in suspension lightweight breathig tube large head sizes 7 8 Requires one of the following Bullard hard hat models 3000 3000R 51WHP or 51WHR NOTE Optional accessories include 20LCL lens covers 20RT Clean Breathable Air Source Supplying Grade D ratchet headband suspension 20NC or ES42 chin strap Figure 1 or Higher Air Quality Headband Suspension or Head Protection Hard hat models See Breathing Air Requirements on page 7 3000 3000R 51WHP or 51WHR or suspension models 20TG and 20RT 20LFM and 20LFL have sewn in elastic headband suspensions Breathing Tube for CC20 Respirators 20BT For 20Tu 20TIC 20TICH 20TICS 20SIC and 20SICH 20LFBT For 20LFM and 20LFL Flow Control Device Connects respirator hood to air supply hose Available with a choice of quick disconnect fittings constant or adjustable airflow control and optional climate control devices Flow Control Device Without Climate With Climate Control Devices Control Devices Cold Only Hot Cold Constant Adjustable A F3
21. be with clamp for CC20 only 20LFBT Breathing tube lightweight with clamp for 20LFL and 20LFM hoods only airline mode Breathing Tube Assemblies for CC20 Series Airline Respirators Include breathing tube airflow control device quick disconnect nipple and belt Note 20BT F30 V30 Constant Flow Breathing Tube Assemblies For use with Breathing Air Compressors v30 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple V31 With 1 4 Schrader steel quick disconnect nipple V32 With 1 4 Snap Tite steel quick disconnect nipple V33 With 1 4 Snap Tite brass quick disconnect nipple Constant Flow Breathing Tube Assemblies For use with 20LFM and 20LFL Loose Fitting Facepiece Hoods X30 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple X31 With 1 4 Schrader steel quick disconnect nipple X32 With 1 4 Snap Tite steel quick disconnect nipple X33 With 1 4 Snap Tite brass quick disconnect nipple Constant Flow Breathing Tube Assemblies For use with Bullard Free Air Pumps V35 With 1 2 Industrial Interchange steel Hansen compatible quick disconnect nipple X35 For 20LFM and 20LFL hoods with 1 2 Industrial Interchange steel Hansen compatible quick disconnect nipple V30 Series Breathing Tube Assembly F30 Series Constant Flow Control Valve CATALOG NUMBER DESCRIPTION Adjustable Flow Breathing Tube Assemblies For use with Breathing Air Compressors v40 Wi
22. better at all times The CC20 respirator does not purify air or filter out contaminants Connecting the CC20 respirator to a line supplying nitrogen or other harmful gases could cause death or serious Table of Contents Approval Label 26 05 52ceciclexs as auesiseteckuasearabsenvdas Component Concept CC20 Warnings and Limitations 0 0 0 Operations Protectioni chucninreiacoiet A E EE E E woereukiene et Riad 6 Breathing Air Requirements 2 00 eeeeee ennenen F Breathing Air Pressure TF Breathing Air Supply Hoses and Hose Fittings 7 Breathing Air Pressure Table 2 2002 20e cece cece ee eeee 8 Respirator Assembly Adjusting and Installing Headband in Respirator HOOd REEE A E eas vedeiauawe T 9 Adjusting and Installing Hard Hat In RESpirator HOOG E esgic keen ater E A T 10 nstalling Breathing Tube Assembly in Respirator HOO rneer snide the meee ace AR niente ASEE AES 11 Using Climate Control Devices 200200 cece cece eee 11 Respirator Use DONMING oi dec ced Heeerd Betas Sais dated NE E eee 12 REMOVING A E EE T EEA EE EEEE EET 12 Inspection Cleaning and Storage Hood and Headbani sis eena a e REARS 13 Hard Hat Breathing n EE E daas its Se ied tue E es 14 Flow Control Valve Climate Control Device 2 0005 14 Air Supply Hoses SORAQEE asic tines s AEE SE EAN T TE EENE soars Parts and Accessories
23. chrader steel quick disconnect coupler 46915 With 1 4 Snap Tite steel quick disconnect coupler V10 Series Extension Hose Kits For use with Breathing Air Compressors Include 3 8 I D rubber hose V11 hose to hose adapter fitting and V13 hose to pipe fitting 3 8 hose to 3 8 pipe 5454 25 7 6 m Extension hose kit 5457 50 15 2 m Extension hose kit 5458 100 30 5 m Extension hose kit V5 Series Coiled Hoses For use with Breathing Air Compressors Include 3 8 I D Nylon coiled hose with 1 4 female quick disconnect coupler and 1 4 male quick disconnect nipple V52530 25 7 6 m with 1 4 Industrial Interchange steel Hansen compatible fittings V55030 50 15 2 m with 1 4 Industrial Interchange steel Hansen compatible fittings V52531 25 7 6 m with 1 4 Schrader steel quick 1 4 Schrader 19432 With 1 4 Female NPT 519433 With 3 8 Female NPT 1 4 Snap Tite S519442 With 1 4 Female NPT S17651 With 3 8 Female NPT Couplers Shut Off Type 1 4 Industrial Interchange Hansen compatible V14 With 1 4 Female NPT V15 With 3 8 Male NPT 1 4 Schrader 8 With 1 4 Female NPT 7603 With 1 4 Male NPT 7601 With 3 8 Male NPT 4 Snap Tite m NN V19 With 1 4 Female NPT S17615 With 3 8 Female NPT S17611 With 1 4 Male NPT S17614 With 3 8 Male NPT Hose Adapters Vll Hose to hose 3 8 hose to 3 8 hose V12 Hose to pipe 3 8 hose to 1 4 pipe V13 Hose to pipe 3 8 hose to 3 8 pipe
24. ditions Failure to follow these instructions could result in death or serious injury A CAUTION Do not cut or remove the foam that is inside the CC20 Series Airline Respirator breathing tube The foam helps reduce the noise level of the incoming air supply It does not filter or purify your breathing air NIOSH has approved this respirator with the foam in place Failure to follow these instructions may result in minor or moderate injury and or equipment damage Storage After reusable respirator components have been cleaned and inspected place them in a plastic bag or an airtight container Store the respirator and parts where they will be protected from contamination distortion and damage from elements such as dust direct sunlight heat extreme cold excessive moisture and harmful chemicals Parts and Accessories CC20 Series Airline Respirator User Manual CC20 Series airline respirators consist of five components respirator hood headband suspension or head protection breathing tube flow control device and air supply hose CATALOG CATALOG NUMBER DESCRIPTION NUMBER DESCRIPTION Respirator System Hood with inner bib for use with Bullard hard hat i i 20TICH Tychem QC hard hat not included a CC20SYS Includes 20TIC35 respirator assembly Free Air 20SICH Tychem SL with taped and sealed seams hard hat pump and V20100ST air supply hose and 20LCL lens covers Respirator Assemblies Fo
25. e Inspection Be sure the hose thread is screwed tightly into the breathing tube so no air can escape during use Check the adjustment knob on the flow control device for cracks and other damage Cleaning To clean hand sponge with warm water and mild detergent being careful not to get water inside After cleaning once again carefully inspect flow control valve climate control device for signs of damage If any signs of excessive wear are present replace the flow control valve climate control device or remove the respirator from service Air Supply Hoses Inspection Air supply hose s should be inspected closely for abrasions corrosion cuts cracks and blistering Be sure the hose fittings are crimped tightly to the hose so that no air can escape Make sure the hose has not been kinked or crushed by any equipment that may have rolled over it If any of the above signs are present or any other signs of excessive wear are detected replace the hose s immediately or remove the respirator from service Cleaning The air supply hose s should be hand sponged with warm water and mild detergent rinsed and air dried Do not get water inside the air supply hose After cleaning once again carefully inspect air supply hose s for signs of damage A WARNING Only use air supply hoses that are NIOSH approved for use with the CC20 respirator Other hoses could reduce airflow and protection and expose the wearer to life threatening con
26. e The point of attachment is the point at which the air supply hose connects to the air source A pressure gauge attached to the air source is used to monitor the pressure of air provided to the respirator wearer see Figure 3 Supplied breathing air must AT MINIMUM meet the requirements for Type 1 gaseous air described in the ANSI Compressed Gas Association Commodity Specification G 7 1 for Grade D or higher quality as specified by Federal regulations 42 CFR Part 84 141 b and 29CFR1910 134 i The requirements for Grade D breathable air include ONVGO iiaia dieters hae d aeiia aa iasan dace 19 5 23 5 Hydrocarbons condensed IN NOAM Of GAS ie nea aain ansaa ia a 5 mg m max Carbon monoxide 0cc cece eee eee 10 ppm max Carbon dioxide cece eee eee 1 000 ppm max Odor No toxic contaminants at levels that make air unsafe to breathe Specific measurement of odor in gaseous air is impractical Air may normally have a slight odor The presence of a pronounced odor should render the air unsatisfactory Contact the Compressed Gas Association 1725 Jefferson Davis Highway Arlington VA 22202 or www cganet com for complete details on Commodity Specification G 7 1 Air Source Locate the source of supplied air whether it is a breathing air compressor or an ambient air pump such as a Bullard Free Air pump in a clean air environment Locate the air source far enough from your work site to ensure
27. e of lens cover to clear your vision The 20TICH and 20SICH model respirator hoods require a hard hat Figure 8 Velcro strip Front elastic band fs Figure 9 Velcro tabs Velcro Strip Figure 10 CC20 Series Airline Respirator User Manual Installing Breathing Tube Assembly Installing Breathing Tube Assembly in Hoods in Loose Fitting Facepieces 1 Remove nylon clamp from plastic anchor plate on hood see 1 The 20LFM and 20LFL loose fitting facepieces have a sewn in Figure 11 Do not remove foam from inside the 20BT breathing tube connector on the back The 20LFBT breathing breathing tube used with CC20 Series Airline Respirators The tube has a special connector on the hood end with bayonet foam helps reduce the noise level of incoming air type pins 2 Insert the bayonet connector of the 20LFBT breathing tube in the hood connector and turn clockwise until it locks in place see Figure 14 To remove To tighten To tighten Figure 11 Figure 14 2 Insert the open end of the breathing tube approximately five inches into hood s air entry sleeve see Figure 12 Using Climate Control Devices for ast CC20 Series Airline Respirators CC20 Series Airline Respirators are approved by NIOSH for use with four optional Bullard climate control devices AC1000 Series DC50 Series HC2400 Series and Frigitron 2000 Series WARNING Climate control devices are not approved for use
28. g facepiece hoods remove the breathing tube by turning the connector on the tube counter clockwise and pulling out Inspect headband suspension for cracks frayed or cut crown straps torn headband or size adjustment slots loss of pliability or other signs of excessive wear Check the chin strap for loss of elasticity cuts and cracked hanger clips If damage is detected replace immediately with Bullard replacement part s or remove the respirator from service Cleaning Bullard does not recommend laundering the hood When the hood becomes dirty it should be discarded and replaced The respirator s plastic lens headband suspension and optional chin strap should be hand sponged with warm water and mild detergent rinsed and air dried Mineral spirits may be used to remove paints or coatings from the solvent resistant lens of the 20 TP and 20TPC hoods After cleaning and before reassembling once again carefully inspect parts for signs of damage A CAUTION Do not use volatile solvents for cleaning this respirator or any parts and assemblies with the exception that mineral spirits may be used to clean the solvent resistant lens of the 20TP and 20TPC hoods Strong cleaning and disinfecting agents and many solvents can damage the plastic parts and reduce the protective properties of the respirator Failure to heed these instructions may result in minor or moderate injury and or equipment damage User Manual A Je1
29. he respiratory hazard s in the workplace and that this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard s and an identification of the contaminant s chemical state and physical form 5 DO NOT wear this respirator if any of the following ambient conditions exist Atmosphere is immediately dangerous to your life or health IDLH IDLH is defined in 29 CFR 1910 134 b You CANNOT escape without the aid of the respirator Atmosphere contains less than 19 5 oxygen Work area is poorly ventilated Unknown contaminants are present Contaminant concentrations are in excess of regulations or recommendations as described in item 4 above 6 There are users environments and chemicals for which these respirators are not suitable It is the responsibility of the user and the employer to determine that these respirators are appropriate for the intended use These respirators should not be used around heat open flames sparks or in any potentially flammable or explosive environment CC20 materials will burn and will melt DuPont Tychem spunbonded olefin apparel fabrics have Class 1 Normal Flammability characteristics as tested according to the Flammable Fabrics Act Class 1 fabrics will burn and do not provide thermal protection if a fire or explosion should occur CC20 materials may create static electricity under low relative humidity Surface resistance and charge dissipation are
30. ice W Determine that your Bullard air supply hose is within the approved length Column 4 4 Make sure you have not exceeded the maximum number of hose sections Column 5 uo Set the air pressure at the point of attachment within the required pressure range Column 6 for your flow control valve climate control device and air supply hose type and length CC20 Breathing Air Supply Hoses and Hose Fittings NIOSH approved Bullard air supply hose s MUST be used between the breathing tube connection fitting on the wearer s belt and the point of attachment to the air supply NIOSH approved Bullard quick disconnect fittings MUST be used to connect V5 or V20 hose lengths together When connecting lengths of V10 hose only use Bullard V11 hose to hose adapters Secure connection s until wrench tight and leak free Total connected hose length and number of hoses MUST be within the ranges specified on the Breathing Air Pressure Table see page 8 The breathing tube connection fitting MUST be secured to the belt that is supplied with this respirator Securing the breathing tube connection helps prevent the air supply hose from snagging disconnecting or pulling the respirator hood off your head User Manual Respirator Air Supply A Hose Point of Pressure Attachment Gauge Grade D Breathable z Air Source Figure 3 Use either a V13 hose to hose pipe adapter or a quick disconnect coupler to attach the
31. o 5 pue buiues uop dsur B Inspection Cleaning and Storage Bullard Hard Hat Inspection Inspect the hard hat shell for nicks gouges cracks and any damage due to impact rough treatment or wear Remove the headband suspension and optional chin strap from the hard hat Inspect the headband suspension for cracks frayed or cut crown straps torn headband and size adjustment slots loss of pliability or other signs of excessive wear Check the chin strap for loss of elasticity cuts and cracked hanger clips If damage is detected replace part s immediately with Bullard replacement parts or remove the hard hat from service Cleaning The hard hat shell headband suspension and optional chin strap should be hand cleaned with warm water and mild detergent rinsed and air dried After cleaning and before reassembling once again carefully inspect parts for signs of damage Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided If any signs of excessive wear are present replace the breathing tube immediately or remove the respirator from service Cleaning To clean the breathing tube hand sponge with warm water and mild detergent being careful not to get water inside Rinse and air dry After cleaning once again carefully inspect breathing tube for signs of damage Flow Control Valve Climate Control Devic
32. proportional to the amount of antistatic agent on the fabric and the ambient relative humidity Since the antistatic agent is water soluble it can be washed off with water In addition other clothing items that are not anti static treated might be a potential source of static formation and discharge Contact your employer or DuPont at 1 800 44 TYVEK on this material 7 Bullard recommends that you DO NOT wear these respirators until you have passed a complete physical exam including a chest x ray conducted by qualified medical personnel 8 Do not modify or alter these respirators in any manner Use only CC20 components and replacement parts manufactured by Bullard and approved by NIOSH for use with this respirator Failure to use Bullard components and replacement parts approved by NIOSH for use with this respirator voids NIOSH approval of the entire respirator invalidates all Bullard warranties and could result in death or serious injury lung disease or exposure to other hazardous or life threatening conditions 9 Inspect all components of these respirator systems during cleaning and before and after each use for signs of wear tear or damage that might reduce the degree of protection originally provided Immediately replace worn or damaged components with Bullard CC20 components approved by NIOSH for use with this respirator or remove the respirator from service See INSPECTION CLEANING AND STORAGE section for instructions on proper maintenance
33. r use with compressed air CC20TJ30 Includes 20TUN hood 20TG headband suspension and V30 breathing tube assembly CC20TIC30 Includes 20TCN hood 20TG headband suspension and V30 breathing tube assembly CC20TICH30 Includes 20TICH hood 20TG headband suspension and V30 breathing tube assembly Includes 20LFL hood and X30 breathing tube assembly CC20LF30 For use with Bullard Free Air pumps CC20TJ35 Includes 20TUN hood 20TG suspension and V35 breathing tube assembly CC20TIC35 Includes 20TCN hood 20TG suspension and V35 breathing tube assembly CC20TICH35 Includes 20TICH hood 20TG suspension and V35 breathing tube assembly Includes 20LFL hood and X35 breathing tube assembly CC20LF35 Respirator Hoods Basic style hood for use with headband suspension 20TU Tychem QC with 20TG headband suspension 20TUN Tychem QC no headband suspension 20TP Tychem QC with solvent resistant polyester lens 20TG headband suspension CC20 only 20TPN Tychem QC with solvent resistant polyester lens no suspension CC20 only Hood with inner bib for use with headband suspension 20TIC Tychem QC with 20TG headband suspension 20TICN Tychem QC no headband suspension 20TPC Tychem QC with solvent resistant polyester lens 20TG headband suspension CC20 only 20TPCN Tychem QC with solvent resistant polyester lens no suspension CC20 only 20TIC 20TJN 3 20TICN 20TP 20TPC 20TPN A 20TPCN eA 20TICH 20
34. respirator use could result in death or serious injury Improper use may also cause certain life threatening delayed lung diseases such as silicosis pneumoconiosis or asbestosis 2 This respirator when properly fitted and used significantly reduces but does not completely eliminate the breathing of contaminants by the respirator wearer Where excessive airborne contaminant levels are found you may obtain better respiratory protection from other types of respiratory protection equipment such as a valve operated pressure demand airline respirator or a pressure demand self contained breathing apparatus respirator 3 Regulations require that the employer provide training to the user on the proper use maintenance and limitations of this equipment Each person using this respirator must first read and understand this entire instruction manual The CC20 Series respirators should only be used in accordance with these operating and maintenance instructions If you have any questions concerning the use of this respirator ask your employer or call Bullard Technical Support at 877 BULLARD 285 5273 4 Before using these respirators be sure your employer has determined that ambient airborne contaminant concentrations do not exceed those allowed by applicable OSHA MSHA EPA NIOSH or ACGIH regulations and recommendations or any other applicable regulations Before using the above respirator Federal law requires that the employer shall identify and evaluate t
35. t becomes damaged Airflow into respirator hood stops or slows down Air pressure gauge drops below the minimum specified in the Breathing Air Pressure Table Breathing becomes difficult You become dizzy nauseous too hot too cold or ill You taste smell or see contaminants inside respirator hood Your vision becomes impaired A WARNING Do not store respirator in your work area or leave it unattended in a contaminated environment Respirable contaminants can remain suspended in the air for several hours after work activity ceases even though you may not see them Proper work practice requires you to wear the respirator until you are outside the contaminated area If you place or store the respirator in a contaminated environment contaminants dirt and dust could get into the respirator When you put the respirator back on you could breathe in contaminants upon reuse Failure to heed these instructions could result in death or serious injury Bullard CC20 Series respirators have a limited service life Therefore a regular inspection and replacement program must be conducted The Bullard CC20 Series respirators and all component parts and assemblies should be inspected for damage or excessive wear before and after each use to ensure proper functioning Immediately remove the respirator from service and replace parts or assemblies that show any sign of failure or excessive wear that might reduce the degree
36. t suspensions RS4PC or ES ULTRA or the optional ratchet suspensions RS4RC or ESRTSL by following the directions on instruction sheet attached to headband on hard hat Read all hard hat warning labels and instructions The following Bullard hard hat models are NIOSH approved for use with CC20 Series respirator hoods 3000 3000R 51WHP and 51WHR Nn Tf desired install and adjust optional ES42 hard hat chin strap Ww Before inserting hard hat into hood remove the two adhesive backed Velcro strips attached to the Velcro piece that is sewn into the hood see Figures 9 amp 10 Peel the backing off the longer Velcro tab and apply it to the inside center rear of the hard hat about 1 4 up from the edge Apply shorter Velcro tab to the underside of the brim of the hard hat see Figure 9 gt uo Insert hard hat into respirator hood with cap visor facing front of hood see Figure 8 6 Tuck cap brim on top of front elastic Velcro band sewn into hood see Figure 9 N Loop the Velcro strip sewn inside the hood around the back of the cap and affix it to the corresponding Velcro tab previously installed inside the hard hat in step 4 see Figure 10 8 Remove protective plastic from plastic lens of respirator hood If desired apply optional 20LC or 20LCL adhesive backed lens covers designed to protect the respirator s plastic lens Apply 2 3 lenses at a time When lens becomes soiled remove by pulling tab at edg
37. ted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance of these respirators S Special or critical User s Instructions and or specific use limitations apply Refer to User s Instructions before donning w 1 qe7 yeaouddy 029 gt CC20 Component Concept Bullard Component Concept Respirator Hood or A y loose fitting facepiece hood CC20 Airline Respi rators Headband Suspension or Hard Hat Bullard CC20 Series airline respirators consist of five components Figure 1 all must be present and properly assembled to constitute a complete NIOSH approved respirator Respirator Hood Available in a variety of styles including loose fitting facepiece and in two Tychem based materials 20TJ Tychem QC basic hood and headband suspension 20TP ychem QC basic hood and headband with solvent resistant polyester lens 20TIC ychem QC hood with inner bib and headband 20TPC ychem QC hood with inner bib and headband with solvent resistant polyester lens 20TICH Tychem QC hood with inner bib for use with head protection 20TICS Tychem QC hood with taped and sealed seams with inner bib long outer bib and headband suspension 20SIC ychem SL hood with taped and se
38. th 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple V4l With 1 4 Schrader steel quick disconnect nipple V43 With 1 4 Snap Tite brass quick disconnect nipple X40 For 20LFM and 20LFL hoods with 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple Replacement Parts for Breathing Tube Assemblies S18051 Nylon breathing tube clamp 4612 Belt Nylon webbing V40 Series Breathing Tube Assembly 20BT Breathing Tube 18051 Clamp F40 Series Constant Flow Control Valve CATALOG NUMBER DESCRIPTION Flow Control Devices for CC20 Series Airline Respirators Flow Control Valves F30 Constant flow control valve with 1 4 Industrial Interchange Hansen compatible quick disconnect nipple other industrial fittings available F40 Adjustable flow control valve with 1 4 Industrial Interchange Hansen compatible quick disconnect nipple other industrial fittings available F35 Constant flow control valve with 1 2 Industrial Interchange Hansen compatible quick disconnect nipple Climate Control Assemblies for CC20 Series Airline Respirators For use with Breathing Air Compressors Cold Tubes Adjustable Flow AC1000 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple AC100031 With 1 4 Schrader steel quick disconnect nipple AC100032 With 1 4 Snap Tite steel quick disconnect nipple Hot Cold Tubes Adjustable Flow HC24
39. to hood with headband suspension snaps facing front 5 Engage four headband suspension snaps into corresponding snap studs mounted in plastic lens see Figure 5 Figure 5 Adjusting Crown Straps for Vertical Fit To improve the comfort of 20TG and 20RT headband suspensions adjust the crown straps vertically by repositioning the headband suspension keys in the crown straps Vertical adjustment makes headband suspension ride higher or lower on the wearer s head To adjust the crown strap 1 Remove headband suspension from respirator hood 2 Rotate crown strap 90 until key dislodges from keyhole see Figure 6 CC20 Series Airline Respirator User Manual Crown Strap Headband Headband Suspension Suspension Key Key Hole Dania Brow Pad z Figure 6 3 Move key to desired vertical position 4 Rotate crown strap 90 to secure key in keyhole see Figure 7 Ratchet Knob Headband Figure 7 5 Repeat steps 2 4 for other crown strap keys 6 Reinstall headband suspension into CC20 respirator hood following directions above IEY NOTE 20LFM and 20LFL loose fitting facepiece hoods have a sewn in headband ILS NOTE Tf the hood rises off your head during use select a different hood for your application or use the optional chin strap o pueqpeay Bupeysur Bunsnfpy B Installing Hard Hat Bullard Adjusting and Installing Hard Hat in Respirator Hood 1 Assemble and adjust the standard Bullard hard ha
40. with Powered Air Purifying Respirators Failure to heed these instructions Figure 12 could result in death or serious injury 3 Install nylon clamp over air entry sleeve and breathing tube l Follow the instructions supplied with your climate control inserting clamp locks through two holes in plastic anchorplate device that is sewn into hood Locks should face away from users 2 Be sure to use only the 20BT with your climate control device neck see Figure 13 9 3 Screw nylon hose connector on end of breathing tube to hose ae thread on climate control device 2 Z 4 Firmly tighten hose connector by hand see Figure 15 Figure 13 4 Engage clamp locks and squeeze together until tight 5 For CC20 Series Airline Respirators attach other end of 20 BT breathing tube to flow control device on belt by screwing nylon hose connector on flow control device 5 Lace belt supplied with respirator through belt loop bracket on climate control device NOTE Refer to PAPR manual for connection of breathing tube to PAPR blower Figure 15 E s Jln q 101 U0 9 eW1 Ajquiassy qn Huryze g RI CC20 Respirator Use Donning Doffing Bullard CC20 Respirator Use WARNING Do not put on or remove these respirators in a hazardous atmosphere except for emergency escape purposes Failure to heed these warnings could result in death or serious injury Donning the CC20 Respirator Before using your C
41. www bullard com 1S0 9001 certified 2007 Bullard All rights reserved Free Air Sure Lock and Frigitron are registered trademarks of Bullard Tt s Your Life and You re Worth It and Dual Cool are trademarks of Bullard Tychem is a registered trademark of E I DuPont de Nemours amp Company Velcro is a registered trademark of Velcro USA 6088001040 0207
Download Pdf Manuals
Related Search
Related Contents
TIMEX IRONMAN Move x20 Activity Tracker Full Leica Manuel de l`utilisateur User manual Kit 59561 - Air Lift KMBT_C654-20140818204240 Toshiba 27A40 CRT Television User Manual CC-Link IE Field Network Ethernet Adapter Module User`s Manual COD. 15.5010.00 順番待ちサービスについて Freie Werkstattketten: So nah und doch so fern Copyright © All rights reserved.