Home
WT‐9002N GSM Intercom
Contents
1. WT 9002N GSM Intercom USER MANUAL WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual FE INTRODUCTION The WT 9002N is a GSM Intercom that comes with its own stainless steel external call point and when a visitor at the gate presses the call button the system will call the numbers programmed regardless of the location of the telephone being called The system can call up to 5 mobile phones or landline number in the order they were programmed Once the owner has responded by answering the call the visitor at the gate and the owner can have a normal two way conversation voice communication If the owner decides to allow the visitor to enter the premises all the owner has to do is use speed dial to call the gate and the gate will open without incurring call costs The WT 9002N is also an access control system You can register up to 5 users into the system and if any of these users calls the system it will reject the call and open the gate without any cost of call If the incoming call is not the registered user the gate will not open The system usesa CE and FCC approved industry internal power supply connected on board A backup lithium battery can power up to 8 hours and will send a power down or power restored alerts in the event of any circuit s power failure The interface is housed in a back flanged IP 65 rated enclosure and can be located and fixed without having to open the cover or requiring any internal fixing
2. Master Check the relay status in ON relay lt ON gt if the relay is or OFF Mode 2013 10 10 16 10 on The unit will return Thu Master relay lt OFF gt if the relay is off Check Signal Strength CSQ lt 28 gt If the signal is too weak the unit will not function 2013 10 10 16 11 properly Thu CSQ 5 12 Signal too weak CSQ 13 24 Signal Good CSQ 25 32 Signal Excellent Time change OK YYYY 4 digit for year Setting the year month day 12 YYYYMMDDHHMMX MM 2 digit for Month hours minutes week 2013 10 10 16 05 DD 2 digit for Date Thu HH 2 digit for Hour MM 2 digit for Minutes X 1 7 Day of the Week SMS Message when the 21 N Message switch N 0 Message OFF system ON OFF lt ON gt N 1 Message ON 2013 10 10 17 06 Factory Default as SMS Thu Message ON To receive SMS Message or not 22 NH After sending N 0 Message OFF to receive SMS Message when command 22 0 N 1 Message ON the system is triggered by a Status switch lt OFF gt phone call Factory Default as SMS 2013 10 10 17 10 Message ON Thu After sending command 22 1 Master relay lt ON gt 2013 10 10 17 08 Thu WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual V1 0 m When Setting as Security mode Open Mode Security Mode N 1 Security mode Only 23 1 Mode switch allow the numbers in the lt ON gt list to control the system 2013 10 10 17 13 N 0 Open mode Anybody Thu can call to the unit to control the system When Setting
3. the externa control devices i e Magnetic Door Sensor DCi2V The mx powers that can control are AC240V 20A Connector to Connect with MIC Left to Shield Ground Wire Right to White positive Shielded Wire WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual V1 0 l5 Warranty Witura Technology Sdn Bhd warrantees the WT 9002N GSM Intercom against defective parts and workmanship Witura Technology Sdn Bhd shall at its option repair or replace the defective equipment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres The WT 9002N is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co Ltd WARNING For safety reasons only connect equipment with a telecommunications compliance label This includes customer equipment previously labelled permitted or certified WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual V1 0 E
4. ECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual lh Enter programming mode You only can perform the next commands after enter into programming mode 0 1234 new password For example if you need to change to the new password of 1212 0 1234 1212 1 1 telephone number Add telephone number into the admin list For example set Admin number 18617185300 into admin 2 1 2 18617185300 Check phone number you program in the list Delete an admin number 3 N N Admin number 1 5 For example if you want to delete admin no 2 just enter 3 2 You get administrator privileges 2013 10 09 00 33 Wed New password lt 1212 gt 2013 10 10 16 07 Thu Administrator 1 15989427391 2 18617185300 2013 10 10 16 08 Thu Administrator 1 15989427391 2 18617185300 2013019019 16 09 Thu Administrator 1 15989427391 2 3 4 5 2013019019 17 16 Thu When you enter 0 12344 you enter into programming mode Maximum 4 digits of passwords Set Admin Numbers 1 1 set 1st admin number set 2nd admin number set 3rd admin number set 4th admin number set 5th admin number 1 2 1 3 1 4 1 5 Delete Admin Number Delete 1st admin 3 1 Delete 2nd admin 3 2 Delete 3rd admin 3 3 Delete 4th admin 3 4 Delete 5th admin 3 5 WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual V1 0 Master relay lt ON gt The unit will return
5. ad and react to the message you will need to insert the SIM card into an unlocked mobile phone After successfully registering the SIM card ensure there is sufficient credit on the card for programming confirmation texts to be sent from the GSM Intercom You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Intercom If you do not disable the PIN request the GSM Intercom will not work If the PIN request is not disabled and the unit is switched on more than 3 times you may have to reset the PIN using the PUK code which will have to be obtained from the service provider To check the PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the disable PIN request and disable it You MUST disable any voicemail that is set up on the SIM card The SIM card is now ready to use Insert the SIM card and carefully close the carrier When first booting up the system you will see green LED lights on the side of the enclosure and it should light up when the network is applied to the unit The green LED is the network indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network WITURA T
6. as Open Factory Default is N 1 for Mode 23 0 Security Mode Mode switch lt OFF gt 2013 10 10 17 13 Thu When Setting as SMS Text Message to Switch 24 NH 24 1H N 1 means switch on the On Off Master relay ON relay by SMS Message Relay 2013 10 10 17 13 N 0 means switch off the Thu relay by SMS Message When Setting as 24 0H Master relay lt OFF gt 2013 10 10 17 13 Thu SPECIFICATIONS Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 1x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps 230v ac per relay GSM Frequency MHz GSM 850 GSM 900 GSM 1800 GSM 1900 Humidity Less Than 80 RH Operating Temperature 20c to 55c Physical Size 130 x 100 x 50mm Protection IP 65 Weather Proof Casing Approvals C E FCC ETSI WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual V1 0 3G GSM Module SIM Card Holder Antenna FACTORY RESET If you required you can rest the system by simply pressing the button FACTORY on the control board until you hear the du This indicates the unit back to the factory default Reset Button Connector to connect the wire from the press button GND to Black Wire Another to RED Wire Press until you hear the du sound Connector to Connect With Speaker Left to Yellow Wire Right to White Wire 12V 12V Connect with the Power of
7. s within the enclosure making a secure and waterproof installation giving maximum protection of the control equipment inside The call point is a two piece fixing with the shield located and fixed and the main intercom fascia locked into place and secured via the security fixing on the under frame of casing and again providing a very secure vandal resistant and waterproof housing It is advised the distance from the interface to the call point does not exceed 3 meters WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual EN It is recommended that the GSM Intercom be programmed to operate as required before final installation Connection Details Connector 1 2 3 4 5 6 7 8 9 10 11 12 Label J16 J3 Power Supply J17 J18 Description Line GND Relay Output Power Supply Input MIC MIC SPK SPK Press Press Details Button Button NC NO Com GND N L MIC MIC SPK SPK Wire 1 Wire 2 WITURA TECHNOLOGY SDN BHD WT 9002N GSM Intercom User Manual leq PREPARING THE SIM CARD All new SIM cards have to be registered with the network provider before they can be used usually by calling the network provider or registering on their website please refer to the instructions supplied with your SIM card During the registration procedure a confirmation code or text message is usually sent to the SIM cards telephone number to be able to re
Download Pdf Manuals
Related Search
Related Contents
Válvulas de mariposa Novus Perfora Line Desktop Magazine File Weider WEEVSY8721 User's Manual Manual - Bildiagnosebutikken.no Fiche technique du produit guía práctica del usuario de la chimenea eléctrica compacta ProteoLens in - Discovery Informatics and Computing Group 取扱説明書 取付・設置説明書 JIS Z 4752-3-1 - 日本画像医療システム工業会 Copyright © All rights reserved.