MLDOORPLUS User`s Manual

image

Contents

1. taken to Inspection mode At this moment the door is stable It is provided to do the mechanical adjustments without cutting the power by operator At this moment some functions are assigned to ENTER UP DOWN buttons This functions are described below To exit Inspection mode must be pressed ESC button Pressing ESC button on board it is taken to Manual Movement mode At this moment it is moved in direction of door closing by pressing UP button it is moved in direction of door opening by pressing DOWN button To exit Manual Movement must be pressed ENTER button INSPECTION MODE KEY DEFINITIONS ENTER By pressing this button during 2 sec it is started programming mode UP By pressing this button Total Run number is screened on LCD during 5 sec DOWN By pressing this button door lenght Teaching is started Door is opened with teaching speed first Then it 1s closed with teaching speed While teaching operation detected encoder value is screened on upper right side of LCD ESC By pressing this button it is exit from Inspection PROGRAMMING Ver 1 01 e To programming of MLDOORPLUS card by pressing ENTER button it is taken to Inspection mode first At this mode by pressing ENTER button again it is started programming Program No Program Name Registered Parameter Value When this sign on screen parameter value can be changed e You can choose any program by using UP and DOWN but
2. IMIT CLOSE P11 Low speed distance when closing Close High b l LIMIT P45 Skate Zone Speed Close Low ess gt Speed Skate Close Speed DISTANCE cm MLDOORPLUS CARD CONNECTION TO LIFT CONTROL SYSTEM 1 Connection with using 24VDC that coming from Control Panel Recommended MLDOORPLUS 24V GNDFC 142 EIN EA EB GND 5V COM OPEN CLOSESLOW FAST Ba Wee Se BA Sist Floor Level J F Contact Photocell Open Contact 1000 100 a A 24 VDC 24 VDC RA RA Door opening relay open contact RK Door closing relay open contact eee e e e e e e e e e o e a MLDOORPLUS 24VGND FC 142 EIN EA EB GND 5V COM OPENCLOSE SLOW FAST Nest Floor Level JF Contact Photocell Open Contact 1000 100 ao ra 24 VDC 24 VDC gt RA RA Door opening relay open contact RK Door closing relay open contact
3. MLDOORPLUS AUTOMATIC DOOR CONTROL CARD TERMINAL EXPLANATIONS AC20 Transformator Input Motor power 10W MOTOR 24 V DC Motor EI Open with Battery CH Open with Extra Power 24V 24V internal supply for input signals pin GND 24V internal supply for input signals pin o V FC Photocell signal input 142 Floor level signal input o Q EIN Rezerved input aa EA Encoder A Channel EB Encoder B Channel GND Encoder supply 5V Encoder supply 24V GND FC 142 EIN EA EB GND 5V COM OPEN CLOSE SLOW FAST COM Common for speed signals OPEN Open signal input CLOSE Close signal input SLOW Slow close signal Nudging input FAST Fast signal input AKU Battery 2 qty 12V 1 2 Ah dry battery AKU Battery CLI Door closed relay common CL2 Door closed relay NO contact OP1 Door open relay common OP2 Door open relay NO contact FL1 Fault and photocell detect relay common FL2 Fault and photocell detect relay NO contact USAGE INFORMATION Door situation informations are shown upper line of LCD screen Door speed is screened at left side of bottom line V X Xcm s and position information at right side P XXXcm When the first power ON the door is moved in the direction of openning if there is not CLOSE input and it is moved in the direction of closing if there is CLOSE input with teaching speed At this operation moment because of missing door location is screened on LCD Pressing ENTER on board it is
4. lay contact which activated when detected pressure or photocell 16 142 Function Passive Passive Open At Floor ClosedAtFloor Chosing rescue mode with at floor signal action when selected Open with Battery When there is Open with Battery situation these situations are applied by looking this parameter Passive Door is opened without looking 142 input Open At Floor Door is not open if there is 142input if there is not it is opened Close At Floor Door is not opened if there is not 142 input if there is it is opened Open amp Battery Open amp Ext Pow Chosing rescue mode 18 Demo Mode Passive Iptal O1s 30s If the value is passive there is no demo It is always provided the door working at waiting door open and close during the value of selected second without noticing door open close signal 19 SetUserPassw Changing user password 20 CanselU Pass Canceling the password with changing 0000 Manufact Setting CAUTION Door manufacturer can be reach these parameters 99 Factory Set NG All parameter values are changed into factory settings OPENING TRAVEL CURVES SPEED cm s P45 Skate Zone P03 Accelerating ramp when opening CLOSE P04 Slowing down ramp when opening LIMIT P05 Low speed distance when opening OPEN LIMIT Open High Speed Skate Open Speed DISTANCE cm CLOSING SPEED cm s P09 Accelerating ramp when closing P10 Slowing down ramp when closing OPEN L
5. tons e To exit programming mode ESC button is pressed in main menu Exit gt ENTER Return gt ESC is screened on LCD When pressed ENTER button it is exit from programming mode and by pressing ESC button it is returned to first menu which is operated e When ENTER button in the main menu is pressed the program on the screen starts e If the program has parameter an arrow appears at the beginning of the second line of LCD screen You can change the parameter value by using UP and DOWN buttons To store the value press the ENTER button and return the main menu By pressing the ESC button the registered value is valid and you can return the main menu Factory Settings Parameters Explanations 00 aka Turkce English High speed when opening Low speed when openning Accelerating ramp adjusment when openning Slowing down ramp adjustment when openning meme gt Low speed movement distance when openning ee SE Pressure level adjustment when openning High speed when closing Low speed when closing Accelerating ramp adjusment when closing Slowing down ramp adjustment when closing Low speed movement distance when closing Pressure level adjustment when closing 1 3 Run InputType Open Close Open Close Close Working the door with Open Close or only Close Chosing contact of Limit relays 15 PressureRelay Open Contact Open Contact Close Contact Chosing fault re

Download Pdf Manuals

image

Related Search

Related Contents

DERNIER TRIMESTRE 2012  Frigidaire FCCS071FW User's Manual  Herunterladen  Webster 2 User Manual (NW) (CD-116)  Kingwin HDCV-1 storage enclosure  Jwin JXCD8500 Shelf System  Pumpenregler  corso di programmazione microcontrollori  LKAT Plus BI-DIRECTIONAL HIGH CURRENT  Manual Rastreo Satelital Quantom 2011  