Home

SIMATIC S7-1200 – Micro Controller for Totally Integrated

image

Contents

1. dicular axes dicular axes dicular axes Degree of protection IP20 Yes Yes Yes Standards approvals certificates CE mark Yes Yes Yes C TICK Yes Yes Yes cULus Yes Yes Yes FM approval Yes Yes Yes Dimensions and weight Dimensions and weight e Width 90 mm 90 mm 90 mm e Height 100 mm 100 mm 100 mm e Depth 75mm 75mm 75mm Weight e Approx weight 425 g 370g 385 g Siemens ST 70 N April 2009 2 23 SIMATIC S7 1200 Central processing units Siemens AG 2009 a Ordering data Order No Order No CPU 1212C SB 1223 signal board C 6ES7 223 0BD30 0XB0 Compact CPU AC DC relay C 6ES7 212 1BD30 0XB0 integral program data memory 25 KB load memory 1 MB wide range power supply 85 264 V AC Boolean execution times 0 1 us per operation 8 digital inputs 6 digital outputs relays 2 analog inputs expandable by up to 3 communication modules 2 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz Compact CPU DC DC DC C 6ES7 212 1AD30 0XB0 integral program data memory 25 KB load memory 1 MB power supply 24 V DC Boolean execution times 0 1 us per operation 8 digital inputs 6 digital outputs relays 2 analog inputs expandable by up to 3 communication modules 2 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz 24 V DC digital outputs can be used as pulse outputs PTO or pulse width modulated outputs PWM with 100 kHz Compact
2. Encoders Connectable encoders e 2 wire BEROs 2 20 Yes Siemens ST 70 N April 2009 Yes Yes Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XB0O 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Integrated functions Number of counters 4 4 4 ax counter frequency 100 100 100 Frequency meters Yes Yes Yes Controlled positioning Yes Yes Yes PID controllers Yes Yes Yes Number of alarm inputs 4 4 4 Number of pulse outputs 2 Limit frequency pulse 100 kHz Operator control and monitoring Display e Integrated No No No Galvanic isolation Galvanic isolation of digital inputs e Galvanic isolation of digital inputs e Between the channels in groups of 500 V AC for 1 minute 1 500 V AC for 1 minute 4 500 V AC for 1 minute 1 Isolation of digital outputs e Isolation of digital outputs e Between the channels e Between the channels in groups of Yes relays No 2 Yes No Relays No Permissible potential difference Between different circuits 500 V DC between 24 V DC and 5VDC 500 V DC between 24 V DC and 5V DC 500 V DC between 24 V DC and 5 VDC EMC Immunity to static discharge e Immunity to static discharge in accordance with IEC 61000 4 2 test voltage with air disch
3. 2 MB C 6ES7 954 8LB00 0AA0 24 MB C 6ES7 954 8LF00 0AA0 7 1200 automation system System Manual for SIMATIC S7 1200 and STEP 7 Basic German 6ES7 298 8FA30 8AHO English 6ES7 298 8FA30 8BHO STEP 7 Basic engineering software Target system SIMATIC S7 1200 controllers and the associated I O The WinCC Basic which is included permits configuration of the SIMATIC Basic Panels Requirement MS Windows XP SP3 MS Windows Vista SP1 Type of delivery German English with online documentation Single license D 6ES7 822 0AA00 0YA0 STEP 7 Basic Software Update D 6ES7 822 0AA00 0YLO Service 1 year D Subject to export regulations AL N and ECCN EAR99S Siemens AG 2009 SIMATIC S7 1200 rocessing units Central a Overview The superior compact solution With 14 integral input outputs Expandable by 1 signal board SB 2 signal modules SM max 3 communication modules CM E Design The compact CPU 1212C has e 3 device versions with different power supply and control voltages e Integrated power supply either as wide range AC or DC power supply 85 to 264 V AC or 24 V DC e Integrated 24 V encoder load current supply For direct connection of sensors and encoders With 300 mA output current also for use as load power supply e 8 integrated digital inputs 24 V DC current sinking current sourcing IEC type 1 current sinking e 6 integrated digital outputs either 24 V
4. Mechanical and climatic condi tions in operation Climatic conditions in operation e Temperature permissible temperature range permissible temperature change e Atmospheric pressure acc to IEC 60068 2 13 permissible atmospheric pressure permissible operating altitude e Concentration of pollutants SO at RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C o 55 3 C min 1080 795 hPa 1000 m 2000 m S05 lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 3 C min 1080 795 hPa 1000 m 2000 m S0 lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 3 C min 1080 795 hPa 1000 m 2000 m SOs lt 0 5 ppm HS lt 0 1 ppm RH lt 60 without condensation Environmental requirements Operating temperature e Min 0 C 0 C 0 C e Max 15 IC Some 591C e Vertical installation min 0 C One 0 C e Vertical installation max 45 C 45 C 45 C e Horizontal installation min QEG eC ORE e Horizontal installation max 55 55 C 55E Storage transport temperature e Min 40 C 40 C 40 C e Max 70 C 70 C 70 C Atmospheric pressure e Operation min 795 hPa 795 hP
5. Siemens AG 2009 Operator control and monitoring D Technical specifications continued 6AV6 647 0AA11 6AV6 647 0AB11 6AV6 647 0AD11 6AV6 647 0AF11 6AV6 647 0AG11 3AX0 3AX0 3AX0 3AX0 3AX0 Product name SIMATIC KTP400 SIMATIC KTP600 SIMATIC KTP600 SIMATIC KTP1000 SIMATIC TP1500 Basic mono PN Basic mono PN Basic color PN Basic color PN Basic color PN Languages e Online languages e Configuration languages e Fonts 5 DIGCBAMINETCHN traditional CHN simplified DK FIN GR J KP ROK NL N PL P RUS S CZ SK TR H WinCC flexible Standard symbol languages 5 DIGBIFRIMETCHN traditional CHN simplified DK FIN GR J KP ROK NL NL PL PRS S CA SKRE WinCC flexible Standard symbol languages 5 D GB F E CHN traditional CHN simplified DK FIN GR J KP ROK NL N PL P RUS S CZ SK TR H WinCC flexible Standard symbol anguages 5 D GB F E CHN traditional CHN simplified DK FIN GR J KP ROK NL N PL P RUS S CZ SK TR H WinCC flexible Standard symbol languages 5 D GB F E CHN traditional CHN simplified DK FIN GR J KP ROK NL N PL P RUS S CZ SK TR H WinCC flexible Standard symbol languages Transfer Upload Download e Transfer of configuration Ethernet automatic transfer recognition Ethernet automatic transfer recognition Ethernet automatic tra
6. 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO0 Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Shock test e Tested in accordance with IEC 60068 2 27 Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen dicular axes dicular axes dicular axes Degree of protection IP20 Yes Yes Yes Standards approvals certificates CE mark Yes Yes Yes C TICK Yes Yes Yes cULus Yes Yes Yes FM approval Yes Yes Yes Dimensions and weight Dimensions and weight e Width 90 mm 90 mm 90 mm e Height 100 mm 100 mm 100 mm e Depth 75mm 75mm 75mm Weight e Approx weight 420g 370g 380 g Siemens ST 70 N April 2009 2 13 SIMATIC S7 1200 Central processing units a Ordering data Order No Order No Siemens AG 2009 CPU 1211C Compact CPU AC DC relay C 6ES7 211 1BD30 0XBO integral program data memory 25 KB load memory 1 MB wide range power supply 85 264 V AC Boolean execution times 0 1 us per operation 6 digital inputs 4 digital outputs relays 2 analog inputs expandable by up to 3 communication modules and 1 signal board digital inputs can be used as HSC at 100 kHz Compact CPU
7. IP20 Safety class Class 1 Galvanic isolation SELV acc to EN 60950 and EN 50178 Ambient temperature 0 60 C Transport storage temperature 26 85 C Mounting Standard mounting rail EN 60715 35x7 5 15 Dimensions W x H x D in mm 70 x 100 x 75 Approx weight 0 3 kg Certification CE cULus o Ordering data Order No PM 1207 power supply Input 120 230 V AC output 24 V DC 2 5 A 6EP1 332 1SH71 Siemens AG 2009 Operator control and monitoring Basic Panels E Overview E Design az Fani diddddda e The ideal entry level series of 3 8 to 15 for operating and monitoring simple machines and plants e Clear process representation thanks to use of pixel graphics displays e Intuitive operation using Touch and tactile function keys e Equipped with all the necessary basic functions such as alarm logging recipe management plots vector graphics and language switching e Simple connection to the controller via integral Ethernet interface or separate version with RS485 422 a Benefits e Integral component of Totally Integrated Automation TIA Increased productivity minimum engineering overhead reduction in life cycle costs Can be used even where installation space is restricted thanks to vertical configuring 4 and 6 devices Short configuring and commissioning times Service friendly thanks to maintenance free design and long service life of the
8. 35 35 35 35 35 incliniation without external venti lation max relative humidity in 90 90 90 90 90 Temperature e Operation vertical installation 0 C to 50 C 0 C to 50 C 0 C to 50 C 0 C to 50 C 0 C to 50 C e Operation max tilt angle e Transport storage 0 C to 40 C 20 C to 60 C 0 C to 40 C 20 C to 60 C 0 C to 40 C 20 C to 60 C 0 C to 40 C 20 C to 60 C 0 C to 40 C 20 C to 60 C Degree of protection Front IP65 NEMA 4 IP65 NEMA 4 IP65 NEMA 4 IP65 NEMA 4x IP65 NEMA 4x NEMA 4x NEMA 12 NEMA 4x NEMA 12 NEMA 4x NEMA 12 NEMA 12 when NEMA 12 when when installed when installed when installed installed installed Rear IP20 IP20 IP20 IP20 IP20 Certifications amp Standards Certifications CE UL cULus CE UL cULus CE UL cULus CE UL cULus CE UL cULus NEMA 4 NEMA 4x NEMA 4 NEMA 4x NEMA 4 NEMA 4x NEMA 4x NEMA 12 NEMA 4x NEMA 12 NEMA 12 NEMA 12 NEMA 12 0 Options I O devices None None None None None Type of output LED colors None None None None None Acoustics Sound signal Sound signal Sound signal Sound signal Sound signal Interfaces Interfaces 1 x Ethernet RJ45 1x Ethernet RJ45 1x Ethernet RJ45 1 x Ethernet RJ45 1 x Ethernet RJ45 PC card slot No No No No No CF card slot No No No No No Multi Media C
9. Siemens AG 2009 SIMATIC S7 1200 Central rocessing units Overview The clever compact solution With 10 integral input outputs Expandable by 1 signal board SB max 3 communication modules CM Design The compact CPU 1211C has e 3 device versions with different power supply and control voltages e Integrated power supply either as wide range AC or DC power supply 85 to 264 V AC or 24 V DC e Integrated 24 V encoder load current supply For direct connection of sensors and encoders With 300 mA output current also for use as load power supply e 6 integrated digital inputs 24 V DC current sinking current sourcing IEC type 1 current sinking e 4 integrated digital outputs either 24 V DC or relay e 2 integrated analog inputs O to 10 V e 2 pulse outputs PTO with a frequency of up to 100 kHz e Pulse width modulated outputs PWM with a frequency of up to 100 kHz e Integrated Ethernet interface TCP IP native ISO on TCP e 3 fast counters 100 kHz with parameterizable enable and reset inputs can be used simultaneously as up and down counters with separate inputs or for connecting incremental encoders Expansion by additional communication interfaces e g RS485 or RS232 Expansion by analog or digital signals directly on the CPU via signal board with retention of CPU mounting dimensions Optional memory expansion SIMATIC Memory Card PID controller with auto tuning functionality
10. lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m SOs lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation Environmental requirements Operating temperature e Min 0 C 0 C 0 C e Max 15 IC Some 591C e Vertical installation min 0 C One 0 C e Vertical installation max 45 C 45 C 45 C e Horizontal installation min 0 C 0 C 0 C e Horizontal installation max Soe 5 IC B15 AC Storage transport temperature e Min 40 C 40 C 40 C e Max 70 C 70 C 70 C Atmospheric pressure e Operation min 795 hPa 795 hPa 795 hPa e Operation max 1080 hPa 1080 hPa 1080 hPa e Storage transport min 660 hPa 660 hPa 660 hPa e Storage transport max 1080 hPa 1080 hPa 1080 hPa Relative humidity e Operation max 95 no condensation 95 no condensation 95 no condensation Vibrations e Vibrations e In operation tested according to IEC 60068 2 6 2 g mounting in switchboard 1 g mounted on DIN rail Yes EA Siemens ST 70 N April 2009 2 g mounting in switchboard 1 g mounted on DIN rail Yes 2 g mounting in switchboard 1 g mounted on DIN rail Yes Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO
11. Integral real time clock e Interrupt inputs For extremely fast response to rising or falling edges of process signals Removable terminals on all modules Simulator optional For simulating the integrated inputs and for testing the user program Device versions Version Supply voltage Input voltage DI e DC DC DC 24V DC 24V DC e DC DC relay 24V DC 24V DC e AC DC relay 85 264 VAC 24V DC Output voltage DO Output current 24V DC 0 5 A transistor 5 30VDC 2A 5 250 VAC 30 W DC 200 W AC 5 30VDC 2A 5 250 V AC 30 W DC 200 W AC Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central processing units Wrunction time triggered interrupts counter interrupts can be triggered when a setpoint is e Comprehensive instruction set reached or when the direction of counting changes A wide range of operations facilitate programming communication interrupts allow the rapid and easy basic operations such as binary logic operations result exchange of information with peripheral devices such as allocation save count create times load transfer printers or bar code readers compare shift rotate create complement call subprogram e Password protection with local variables integral communication commands e g USS protocol Modbus RTU S7 communication T Send T Receive or e Test and diagnostics functions Easy to use functions support testing and diagnostics
12. a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Climatic and mechanical condi tions for storage and transport Climatic conditions for storage and transport e Free fall max height of fall in packaging e Temperature permissible temperature range e Relative humidity permissible range without condensation at 25 C 0 3 m five times in transport packaging 40 C 70 C 95 0 3 m five times in transport packaging 40 C 70 C 95 0 3 m five times in transport packaging 40 C 70 C 95 Mechanical and climatic condi tions in operation Climatic conditions in operation e Temperature permissible temperature range permissible temperature change e Atmospheric pressure acc to IEC 60068 2 13 permissible atmospheric pressure permissible operating altitude e Concentration of pollutants SO at RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m S05 lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m S0
13. 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XBO 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Integrated functions Number of counters 6 6 6 Max counter frequency 100 kHz 100 kHz 100 kHz Frequency meters Yes Yes Yes Controlled positioning Yes Yes Yes PID controllers Yes Yes Yes Number of alarm inputs 4 4 4 Number of pulse outputs 2 Limit frequency pulse 100 kHz Operator control and monitoring Display e Integrated No No No Galvanic isolation Galvanic isolation of digital inputs e Galvanic isolation of digital inputs e Between the channels 500 V AC for 1 minute 1 500 V AC for 1 minute 4 500 V AC for 1 minute 1 in groups of Isolation of digital outputs e Isolation of digital outputs Relays Yes Relays e Between the channels No No No e Between the channels 2 2 1 in groups of Permissible potential difference Between different circuits 500 V DC 500 V DC 500 V DC between 24 V DC and 5 V DC between 24 V DC and 5 V DC between 24 V DC and 5 V DC EMC Immunity to static discharge e Immunity to static discharge in accordance with IEC 61000 4 2 test voltage with air discharge test voltage with contact discharge Yes 8 kV 6 kV Yes 8 kV 6 kV Yes 8 kV 6 kV Immunity to conducted interference e on the su
14. 2 15 Siemens AG 2009 SIMATIC S7 1200 Central processing units Wirunction OOOO time triggered interrupts counter interrupts can be triggered when a setpoint is e Comprehensive instruction set reached or when the direction of counting changes A wide range of operations facilitate programming communication interrupts allow the rapid and easy basic operations such as binary logic operations result allo exchange of information with peripheral devices such as cation save count create times load transfer compare printers or bar code readers shift rotate create complement call subprogram with local e Password protection variables integral communication commands e g USS protocol Modbus RTU S7 communication T Send T Receive or A Freeport online offline diagnostics user friendly functions such as pulse width modulation Forcing of inputs and outputs during testing and diagnostics pulse sequence function arithmetic functions floating point Inputs and outputs can be set independently of cycle and thus arithmetic PID closed loop control jump functions loop permanently for example to test the user program functions and code conversions Motion Control in accordance with PLCopen for simple move mathematical functions e g SIN COS TAN LN EXP ments e Counting l a eee e Library functionality User friendly counting functions in conjunction with the inte ial for high grated counters an
15. 60 s month at 25 C 60 s month at 25 C 60 s month at 25 C Test and startup functions Status control e Status modify variable Yes Yes Yes e Tags Inputs outputs bit memories DBs Inputs outputs bit memories DBs Inputs outputs bit memories DBs distributed inputs outputs timers distributed inputs outputs timers distributed inputs outputs timers counters counters counters Forcing e Forcing Yes Yes Yes Communications functions S7 communication e Supported Yes Yes Yes e As server Yes Yes Yes e As client Yes Yes Yes Open IE communication e TCP IP Yes Yes Yes data length max e ISO on TCP RFC1006 Yes Yes Yes Number of connections e Total 16 dynamic 16 dynamic 16 dynamic 1st interface Type of interface PROFINET PROFINET PROFINET Physics Ethernet Ethernet Ethernet Isolated Yes Yes Yes Automatic determination of transfer Yes Yes Yes rate Autonegotiation Yes Yes Yes Autocrossover Yes Yes Yes CPU programming Configuring software e STEP 7 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Programming language e KOP Yes Yes Yes e FUP Yes Yes Yes Cycle time monitoring e Configurable Yes Yes Yes 2 28 Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XB0O 6ES7 214 1HE30 0XBO Product name CPU 1214C AC D
16. Basic engineering soft ware Target system SIMATIC S7 1200 controllers and the associated I O The WinCC Basic which is included permits configuration of the SIMATIC Basic Panels Requirement MS Windows XP SP3 MS Windows Vista SP1 Type of delivery German English with online documentation Single license D 6ES7 822 0AA00 0YA0 STEP 7 Basic Software Update D 6ES7 822 0AA00 0YLO Service 1 year E Subject to export regulations AL N and ECCN EAR99T Siemens AG 2009 SIMATIC S7 1200 rocessing units Central a Overview The compact high performance CPU With 24 integral input outputs Expandable by 1 signal board SB 8 signal modules SM max 3 communication modules CM E Design The compact CPU 1214C has e 3 device versions with different power supply and control voltages e Integrated power supply either as wide range AC or DC power supply 85 to 264 V AC or 24 V DC e Integrated 24 V encoder load current supply For direct connection of sensors and encoders With 400 mA the output current can also be used as load power supply e 14 integrated digital inputs 24 V DC current sinking current sourcing IEC type 1 current sinking e 10 integrated digital outputs either 24 V DC or relay e 2 integrated analog inputs O to 10 V e 2 pulse outputs PTO with a frequency of up to 100 kHz e Pulse width modulated outputs PWM with a frequency of up to 100 kHz e Integrated Ethe
17. Buffered period e Deviation per day max Yes 240 h typically 60 s month at 25 C Yes 240 h typically 60 s month at 25 C Yes 240 h typically 60 s month at 25 C Test and startup functions Status control e Status modify variable Yes Yes Yes e Tags Inputs outputs bit memories DBs Inputs outputs bit memories DBs Inputs outputs bit memories DBs distributed inputs outputs timers distributed inputs outputs timers distributed inputs outputs timers counters counters counters Forcing e Forcing Yes Yes Yes Communications functions S7 communication e Supported Yes Yes Yes e As server Yes Yes Yes e As client Yes Yes Yes Open IE communication e TCP IP Yes Yes Yes e ISO on TCP RFC1006 Yes Yes Yes Number of connections e Total 16 dynamic 16 dynamic 16 dynamic 1st interface Type of interface PROFINET PROFINET PROFINET Physics Ethernet Ethernet Ethernet Isolated Yes Yes Yes Automatic determination of transfer Yes Yes Yes rate Autonegotiation Yes Yes Yes Autocrossover Yes Yes Yes CPU programming Configuring software e STEP 7 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Programming language e LAD Yes Yes Yes e FBD Yes Yes Yes Cycle time monitoring e Configurable Yes Yes Yes 218 Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continu
18. DC power supply diagnostics on LEDs S7 1200 module including electronic manual on CD ROM 6GK7 277 1AA00 0AA0 IE FC RJ45 Plug 180 RJ45 plug in connector for Industrial Ethernet with rugged metal enclosure and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables 180 cable outlet for network components and CPs CPUs with Industrial Ethernet interface e 1 pack 1 unit Accessories IE TP Cord RJ45 RJ45 TP cable 4 x 2 with 2 RJ45 connectors 0 5m 6XV1 870 3QE50 e 1 pack 10 units e 1 pack 50 units 6GK1 901 1BB10 2AA0 6GK1 901 1BB10 2AB0 6GK1 901 1BB10 2AE0 IE FC stripping tool Preadjusted stripping tool for fast IE FC TP Standard Cable GP 2 x 2 Type A 4 core shielded TP installation cable for connection to IE FC Outlet RJ45 IE FC RJ45 Plug PROFINET compatible with UL approval sold by the meter max length 1000 m minimum order quantity 20 m 6XV1 840 2AH10 stripping of the Industrial Ethernet FC cables 6GK1 901 1GA00 IE FC Outlet RJ45 For connecting Industrial Ethernet FC cables and TP cords graduated prices for 10 and 50 units or more 6GK1 901 1FC00 OAAO SIMATIC NET Manual Collection Electronic manuals on communi cations systems protocols FC TP Trailing Cable 2 x 2 6XV1 840 3AH10 Type C 4 core shielded TP installation cable for connection to IE FC Outlet RU45 IE FC RJ45 Plug 180
19. DC DC DC C 6ES7 211 1AD30 0XBO integral program data memory 25 KB load memory 1 MB power supply 24 V DC Boolean execution times 0 1 us per operation 6 digital inputs 4 digital outputs relays 2 analog inputs expandable by up to 3 communication modules and 1 signal board digital inputs can be used as HSC at 100 kHz 24 V DC digital outputs can be used as pulse outputs PTO or pulse width modulated outputs PWM with 100 kHz Compact CPU DC DC relay C 6ES7 211 1HD30 0XBO integral program data memory 25 KB load memory 1 MB power supply 24 V DC Boolean execution times 0 1 us per operation 6 digital inputs 4 digital outputs 2 analog inputs expandable by up to 3 communication modules and 1 signal board digital inputs can be used as HSC at 100 kHz C Subject to export regulations AL N and ECCN EAR99H Ey More information Brochures Information material for downloading can be found in the Internet http Awww siemens com simatic printmaterial 274 Siemens ST 70 N April 2009 SB 1223 signal board C 6ES7 223 0BD30 0XB0 2 inputs 24 V DC IEC type 1 current sinking two 24 V DC transistor outputs 0 5 A 5 W can be used as HSC at up to 30 kHz SB 1232 signal board C 6ES7 232 4HA30 0XB0 1 analog output 10 V with 12 bit or 0 20 mA with 11 bit Simulator optional C 6ES7 274 1XF30 0XA0 8 input switches for CPU 1211C CPU 1212C SIMATIC Memory Card optional
20. DC or relay e 2 integrated analog inputs O to 10 V e 2 pulse outputs PTO with a frequency of up to 100 kHz e Pulse width modulated outputs PWM with a frequency of up to 100 kHz e Integrated Ethernet interface TCP IP native ISO on TCP 4 fast counters 3 with max 100 kHz 1 with max 30 kHz with parameterizable enable and reset inputs can be used simul taneously as up and down counters with 2 separate inputs or for connecting incremental encoders Expansion by additional communication interfaces e g RS485 or RS232 Expansion by analog or digital signals directly on the CPU via signal board with retention of CPU mounting dimensions Expansion by a wide range of analog and digital input and output signals via signal modules Optional memory expansion SIMATIC Memory Card PID controller with auto tuning functionality Integral real time clock Interrupt inputs For extremely fast response to rising or falling edges of process signals Removable terminals on all modules Simulator optional For simulating the integrated inputs and for testing the user program Device versions Version Supply voltage Input voltage DI e DC DC DC 24V DC 24V DC e DC DC relay 24 V DC 24V DC e AC DC relay 85 264 VAC 24V DC Output voltage DO Output current 24V DC 0 5 A transistor 55 610 W IDG j 2A 5 250 V AC 30 W DC 200 W AC 5 30VDC 2A 5 250 V AC 30 W DC 200 W AC Siemens ST 70 N April 2009
21. EAR99S Siemens AG 2009 Communication CSM 1277 unmanaged a Overview a Design The CSM 1277 compact switch module offers all advantages of DA A the SIMATIC S7 1200 design aa e Compact design the rugged plastic enclosure contains 4x RJ45 sockets for connecting to Industrial Ethernet 3 pole plug in terminal strip for connection of the external 24 V DC supply on the top LEDs for diagnostics and for status display of the Industrial Ethernet ports e Simple mounting on the mounting rail of the S7 1200 e Fanless and therefore low maintenance design e The module can be replaced without using a programming device al Function e Multiplication of Ethernet interfaces of the SIMATIC S7 1200 e Design of a small local Industrial Ethernet network with three e For connecting a SIMATIC S7 1200 to an Industrial Ethernet further nodes network with a line tree or star topology e Automatic detection of data transfer rate by means of e Up to three further nodes can be connected autosensing and autocrossover functions e Simple space saving mounting on the SIMATIC S7 1200 e Secure industry standard plug in connections mounting rail e LEDs for diagnostics and for status display Biba solution for implementing small local Ethernet Network topology and configuration e Rugged industry standard node connections with RJ45 Various network topologies can be implemented using the connectors CSM 1277 compact switch module e Simple and fas
22. ECCN EAR99S D 6ES7 822 0AA00 0YA0 D 6ES7 822 0AA00 0YL0 H More information Brochures Information material for downloading can be found in the Internet http www siemens com simatic printmaterial Siemens ST 70 N April 2009 5 3 SIMATIC S7 1200 Power supplies PM 1207 power supply Siemens AG 2009 E Overview O Technical specifications e Stabilized power supply for SIMATIC S7 1200 e In S7 1200 design e Input 120 230 V AC output 24 V DC 2 5 A 2 60 Siemens ST 70 N April 2009 PM 1207 power supply Order No 6EP1 332 1SH71 Input voltage rated value 120 230 V AC autoranging e Range 85 132 V 176 264 V AC Mains buffering gt 20 ms at 93 187 V Line frequency rated value 50 60 Hz e Range 47 63 Hz Input current rated value 1 2 0 67 A e Switch on current 25 C lt 13A e Recommended miniature circuit breaker 16 A characteristic B 10 A characteristic C Output voltage rated value 24V DC e Tolerance 3 e Residual ripple lt 150 mVpp e Adjustment range No Output current rated value 2 5A Approx efficiency at rated values 83 Connectable in parallel Yes 2 units Electronic short circuit protection Yes automatic restart Radio suppression level EN 55022 Class B Status display Green LED for 24 V OK Line harmonic limitation EN 61000 3 2 Not applicable Degree of protection EN 60529
23. Horizontal installation max Soe 5 IC B15 AC Storage transport temperature e Min 40 C 40 C 40 C e Max 70 C 70 C 70 C Atmospheric pressure e Operation min 795 hPa 795 hPa 795 hPa e Operation max 1080 hPa 1080 hPa 1080 hPa e Storage transport min 660 hPa 660 hPa 660 hPa e Storage transport max 1080 hPa 1080 hPa 1080 hPa Relative humidity e Operation max 95 no condensation 95 no condensation 95 no condensation Vibrations e Vibrations e in operation tested according to IEC 60068 2 6 2 g mounting in switchboard 1 g mounted on DIN rail Yes 2722 Siemens ST 70 N April 2009 2 g mounting in switchboard 1 g mounted on DIN rail Yes 2 g mounting in switchboard 1 g mounted on DIN rail Yes Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XBO 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Shock test e Tested in accordance with IEC 60068 2 27 Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen
24. at 30 kHz Cable length e Max cable length shielded e Max cable length unshielded 500 m 50 m for technological functions 300 m for technological functions No 500 m 50 m for technological functions 300 m for technological functions No 500 m 50 m for technological functions 300 m for technological functions No Digital outputs Number of digital outputs e of those as fast outputs 10 relays 10 relays 2 100 KHz pulse train output 10 relays Short circuit protection No to be provided externally No to be provided externally No to be provided externally Voltage induced on current inter ruption limited to L 48 V Switching capacity of outputs e with ohmic load max 2A O5A 2A e with lamp load max 30 W DC 200 W AC 5 W 30 W DC 200 W AC Output voltage e for 1 signal min 20 V Output current e for 1 signal rated value O5A e for O signal residual current 0 1 mA max Siemens ST 70 N April 2009 2 29 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XBO 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Output delay with ohmic load e O to 1 max 10 ms max 1 us 10 ms max e 1 to 0 max 10 ms max 5 Us 10 ms max Switching frequency
25. backlighting display e Simple and user friendly representation of process values thanks to for example input output fields vector graphics trend curves bar charts text and bitmaps e Graphics library available with off the shelf picture objects e Can be used worldwide 32 languages can be configured incl Asian and Cyrillic character sets You can switch between up to 5 languages online Language dependent texts and graphics a Application The SIMATIC HMI Basic Panels can be used wherever simple machines and plants are controlled and monitored locally in production process and building automation alike They are used in the most diverse sectors and applications 4 2 Siemens ST 70 N April 2009 The SIMATIC HMI Basic Panels are installation compatible with the existing touch devices of the product family of Panels and Multi Panels e KTP400 Basic mono 3 8 STN mono 1 Ethernet interface TCP IP Touch screen and 4 tactile function keys e KTP600 Basic mono 5 7 STN mono 1 Ethernet interface TCP IP Touch screen and 6 tactile function keys e KTP600 Basic color 5 7 TFT with 256 colors 1 Ethernet interface TCP IP or 1 RS 485 422 interface separate version Touch screen and 6 tactile function keys e KTP1000 Basic color 10 4 TFT with 256 colors 1 Ethernet interface TCP IP or 1 RS 485 422 interface separate version Touch screen and 8 tactile function keys e TP1500 Basic color 15 1 TFT with 256 co
26. e for 1 signal rated value 0 5A e for O signal residual current max 0 1 mA Siemens ST 70 N April 2009 29 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XB0O 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Output delay with ohmic load e O to 1 max 10 ms max 1 us max 10 ms max e 1 to O max 10 ms max 5 us max 10 ms max Wiring 2 outputs in parallel e for performance increase No No Switching frequency e of pulse outputs with ohmic load 1 Hz 100 kHz 1 Hz max Cable length e Max cable length shielded 500 m 500 m 500 m e Max cable length unshielded 150 m 150 m 150 m Relay outputs Number of relay outputs 4 4 Number of operating cycles Mechanically 10 million with rated Mechanically 10 million with rated load voltage 100000 load voltage 100000 Analog inputs Number of analog inputs 2 Number of analog inputs with voltage current measurement ax cable length shielded 10 m twisted and shielded 10 m twisted and shielded 10 m twisted and shielded nput ranges e Voltage Yes Yes Yes nput ranges rated values voltages 0 4 10V e Input resistance 0 10 V Yes gt 100 kOhm Yes 2100 kOhm Yes 2100 kOhm Analog value generation Integration and conv
27. entries non retentive Recipes e Recipes 5 5 5 5 5 e Data records per recipe 20 20 20 20 20 e Entries per data record 20 20 20 20 20 e Recipe memory 40 kB integrated 40 kB integrated AO kB integrated 32 kB integrated 32 kB integrated Flash Flash Flash Flash Flash Number of process images e Process images 50 50 50 50 50 e Variables 128 128 128 256 256 e Limit values Yes Yes Yes Yes Yes e Multiplexing Yes Yes Yes Yes Yes Image elements e Graphics object Bit maps icons icon full screen vector Bit maps icons icon full screen vector Bit maps icons icon full screen vector Bit maps icons icon full screen vector Bit maps icons icon full screen vector graphics graphics graphics graphics graphics e dynamic objects Diagrams Diagrams Diagrams Diagrams Diagrams Lists e Text lists 150 150 150 150 150 e Graphics list 100 100 100 100 100 e Libraries Yes Yes Yes Yes Yes Security e Number of user groups 50 50 50 50 50 e Passwords exportable No No No No No e Number of user rights 32 32 32 32 32 Data medium support e PC card No No No No No e CF card No No No No No e Multi Media Card No No No No No Recording e Recording Printing PROFINET PROFINET PROFINET PROFINET PROFINET Fonts e Keyboard fonts US American US American US American US American US American English English English English English Siemens ST 70 N April 2009 4 5 Basic Panels
28. inputs programmable e for counter technological functions programmable 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 KHz Differential 3 at 80 KHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 KHz Differential 3 at 80 KHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 KHz Differential 3 at 80 KHz Cable length e Max cable length shielded e Max cable length unshielded 500 m 50 m for technological functions 300 m for technological functions No 500 m 50 m for technological functions 300 m for technological functions No 500 m 50 m for technological functions 300 m for technological functions No Digital outputs Number of digital outputs e of those as fast outputs 4 relays 4 2 100 kHz pulse train output 4 relays Short circuit protection No to be provided externally No to be provided externally No to be provided externally Voltage induced on current inter ruption limited to L 48 V Switching capacity of outputs e with ohmic load max 2A 0 5A 2A e with lamp load max 30 W DC 200 W AC 5W 30 W DC 200 W AC Output voltage e for O signal DC max 0 1 V with 10 kOhm load e for 1 signal min 20 V Output current
29. per operation 0 1 us per operation 0 1 us per operation for word operations min 12 us per operation 12 us per operation 12 us per operation for floating point arithmetic min 18 us per operation 18 us per operation 18 us per operation Data areas and their retentivity Total retentive data area including timers counters bit memories max 2048 byte 2048 byte 2048 byte Address range I O address range e Total I O address range 1024 byte for inputs 1024 byte for inputs 1024 byte for inputs 1024 byte for outputs 1024 byte for outputs 1024 byte for outputs e Inputs 1024 byte 1024 byte 1024 byte e Outputs 1024 byte 1024 byte 1024 byte Digital channels e Integrated channels DI 8 8 e Integrated channels DO Analog channels e Integrated channels Al 2 2 2 Siemens ST 70 N April 2009 2 17 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XB0O 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Hardware configuration Number of modules per system max 3 communication modules 1 signal board 2 signal modules 3 communication modules 1 signal board 2 signal modules 3 communication modules 1 signal board 2 signal modules Time Clock e Hardware clock real time clock e
30. per operation 12 us per operation for floating point arithmetic min 18 us per operation 18 us per operation 18 us per operation Data areas and their retentivity Total retentive data area including timers counters bit memories max 2048 byte 2048 byte 2048 byte Address range I O address range e Total I O address range 1024 byte for inputs 1024 byte for inputs 1024 byte for inputs 1024 byte for outputs 1024 byte for outputs 1024 byte for outputs e Inputs 1024 byte 1024 byte 1024 byte e Outputs 1024 byte 1024 byte 1024 byte Digital channels e Integrated channels Dl 14 14 14 e Integrated channels DO 10 10 10 Analog channels e Integrated channels Al 2 2 2 Siemens ST 70 N April 2009 2 27 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XBO 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Hardware configuration Number of modules per system max 3 communication modules 1 signal board 8 signal modules 3 communication modules 1 signal board 8 signal modules 3 communication modules 1 signal board 8 signal modules Time Clock e Hardware clock real time clock Yes Yes Yes e Buffered period 240 h typically 240 h typically 240 h typically e Deviation per day max
31. 14 gt n oO oO KTP400 Basic KTP1000 Basic 2i 5 o SIMATIC PANEL A A f P J SIEMENS SIMATIC PANEL ry 0 Q Go EESE m J X S 8 g E 3 aalala S 1 y H 8 44 62 3 p 400 59 9 6 2 L 214 A cere ames A KTP600 Basic TP1500 Basic More information Additional information is available in the Internet under Note http www siemens com panels Do you require a specific modification to or supplement for the products described here Look in the catalog ST 80 under Customized products We provide information there about additional and generally available sector products and about the customer specific modification and adaptation options 4 8 Siemens ST 70 N April 2009
32. 47 0AB11 6AV6 647 0AD11 6AV6 647 0AF11 6AV6 647 0AG11 3AX0 3AX0 3AX0 3AX0 3AX0 Product name SIMATIC KTP400 SIMATIC KTP600 SIMATIC KTP600 SIMATIC KTP1000 SIMATIC TP1500 Basic mono PN Basic mono PN Basic color PN Basic color PN Basic color PN Supply voltage Supply voltage 24V DC 24 V DC 24 V DC 24 V DC 24 V DC permissible range 19 2 V to 19 2 V to 19 2 V to 19 2 V to 19 2 V to 28 8 V DC 28 8 V DC 28 8 V DC 28 8 V DC 28 8 V DC Rated current 0 07 A 0 24 A 0 35 A 0 6 A 0 24 A Memory Type of storage Type Flash RAM Flash RAM Flash RAM Flash RAM Flash RAM Memory usable for project data Options 512 KB usable memory for user 512 KB usable memory for user 512 KB usable memory for user 1024 KB usable memory for user 1024 KB usable memory for user data data data data data Time Clock e Type Software clock not Software clock not Software clock not Software clock not Software clock not battery backed battery backed battery backed battery backed battery backed Protocols Protocols terminal link e Sm rtAccess No No No No No Configuration Configuration tool WinCC flexible WinCC flexible WinCC flexible WinCC flexible WinCC flexible Compact Version Compact Version Compact Version Compact Version Compact Version 2008 or higher to be 2008 or higher to be 2008 or higher tobe 2008 or higher to be 2008 or higher to be ordered separately ordered separately
33. 90 for use as trailing cable PROFINET compatible with UL approval sold by the meter max length 1000 m minimum order quantity 20 m products on DVD German English 6GK1 975 1AA00 3AA0 Siemens ST 70 N April 2009 as Siemens AG 2009 Software STEP 7 Basic E Overview E Benefits Optimized interaction of controller and HMI engineering Efficient solving of complete automation task through naas e Integrated handling of controller programming and HMI configuration in one engineering framework e Common data management 5 e Integral WinCC Basic configuration environment a the application can be supplemented seamlessly by SIMATIC HMI Basic Panels Fast startup using the portal view n pr te The portal view facilitates navigation e It is also possible for beginners to access each task rapidly and specifically e In the event of maintenance fast access to the online views directly in the portal overview previous downloading of a project is unnecessary Intuitive user interface STEP 7 Basic portal view Use of STEP 7 Basic is extremely intuitive AL Editors matched to the tasks and sequence e Use of the latest Windows technologies x H Application f F STEP 7 Basic is the engineering system for automation systems with SIMATIC S7 1200 In addition to programming of the con troller it permits configuration of the connected SIMATIC HMI Basic Panels in association with the integr
34. AC for 1 minute 1 500 V AC for 1 minute 4 500 V AC for 1 minute 1 Isolation of digital outputs e Isolation of digital outputs e Between the channels e Between the channels in groups of Yes relays No 1 Yes No Relays No Permissible potential difference Between different circuits 500 V DC between 24 V DC and 5 VDC 500 V DC between 24 V DC and 5V DC 500 V DC between 24 V DC and 5 VDC EMC Immunity to static discharge e Immunity to static discharge in accordance with IEC 61000 4 2 test voltage with air discharge test voltage with contact discharge Yes 8 kV 6 kV Yes 8 kV 6 kV Yes 8 kV 6 kV Immunity to conducted interference e On the supply lines in accordance with IEC 61000 4 4 e Immunity on supply lines in accor dance with IEC 61000 4 4 Yes Yes Yes Yes Yes Yes Immunity to surge voltages e On the supply lines in accordance with IEC 61000 4 5 Yes Yes Yes Immunity to conducted inter ference induced by high frequency fields e Immunity to high frequency irradiation in accordance with IEC 61000 4 6 Yes Yes Yes Emission of radio interference in accordance with EN 55 011 e Emission of radio interference in accordance with EN 55 011 limit class A Yes Group 1 Yes Group 1 Yes Group 1 Siemens ST 70 N April 2009 271 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units
35. C relay CPU 1214C DC DC DC CPU 1214C DC DC relay Digital inputs Number of digital inputs e Inputs which can be used for technological functions 14 integrated 6 HSC high speed counting 14 integrated 6 HSC high speed counting 14 integrated 6 HSC high speed counting Current sourcing sinking Yes Yes Yes Concurrently controllable inputs e All mounting positions concurrently controllable inputs 14 14 14 up to 40 C Input voltage e Rated value DC 24V 24V 24 V e for O signal 5VDCat1 mA 5 V DC at 1 mA 5 VDC at 1 mA e for 1 signal 15 V DC at 2 5 mA 15 V DC at 2 5 mA 15 V DC at 2 5 mA Input current e for 1 signal typ 1 mA 1 mA 1 mA Input delay at rated value of input voltage e for standard inputs programmable for 0 to 1 min for O to 1 max e for alarm inputs programmable e for counter technological functions programmable 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 3 at 30 kHz Differential 3 at 80 kHz 3 at 30 kHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 3 at 30 kHz Differential 3 at 80 kHz 3 at 30 kHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 3 at 30 kHz Differential 3 at 80 kHz 3
36. CPU DC DC relay C 6ES7 212 1HD30 0XBO integral program data memory 25 KB load memory 1 MB power supply 24 V DC Boolean execution times 0 1 us per operation 8 digital inputs 6 digital outputs 2 analog inputs expandable by up to 3 communication modules 2 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz C Subject to export regulations AL N and ECCN EAR99H D Subject to export regulations AL N and ECCN EAR99S El More information Brochures Information material for downloading can be found in the Internet http www siemens com simatic printmaterial 2 24 Siemens ST 70 N April 2009 2 inputs 24 V DC IEC type 1 current sinking two 24 V DC transistor outputs 0 5A 5W can be used as HSC at up to 30 kHz SB 1232 signal board C 6ES7 232 4HA30 0XB0 1 analog output 10 V with 12 bit or 0 20 mA with 11 bit Simulator optional C 8 input switches for CPU 1211C 6ES7 274 1XF30 0XA0 CPU 1212C SIMATIC Memory Card optional 2 MB C 6ES7 954 8LB00 0AA0 24 MB C 6ES7 954 8LF00 0AA0 Starter box CPU 1212C E 6ES7 212 1BD30 4YB0 AC DC relay Complete offer SIMATIC S7 1200 starter box comprising CPU 1212C AC DC relay simula tor STEP 7 BASIC CD manual CD info material in Systainer S7 1200 automation system System Manual for SIMATIC S7 1200 and STEP 7 Basic German 6ES7 298 8FA30 8AHO English 6ES7 298 8FA30 8BH0 STEP 7
37. WinCC flexible Communication e German 6AV6 691 1CA01 3AA0 e English 6AV6 691 1CA01 3AB0 e French 6AV6 691 1CA01 3ACO e Italian 6AV6 691 1CA01 3AD0 e Spanish 6AV6 691 1CA01 3AE0 SIMATIC HMI Manual Collection D Electronic documentation on DVD 5 languages English French German Italian and Spanish contains all currently available user manuals manuals and communication manuals for SIMATIC HMI 6AV6 691 1SA01 0AX0 Accessories Accessories for supplementary ordering See Catalog ST 80 E Subject to export regulations AL N and ECCN EAR99T Siemens ST 70 N April 2009 Siemens AG 2009 Operator control and monitoring Basic Panels a Dimensional drawings All dimensions in mm x SIEMENS SIMATIC PANEL x x Cia O oe Q gt T o S oc O N N or onc 0 E E y 8 PLT FI PI PI PI F FI 3 i a Y Si 40 6 2 e x 3 140 hee S al k gt b 335 oe 2
38. a 795 hPa e Operation max 1080 hPa 1080 hPa 1080 hPa e Storage transport min 660 hPa 660 hPa 660 hPa e Storage transport max 1080 hPa 1080 hPa 1080 hPa Relative humidity e Operation max 95 no condensation 95 no condensation 95 no condensation Vibrations e Vibrations e In operation tested according to IEC 60068 2 6 2 g mounting in switchboard 1 g mounted on DIN rail Yes PA Siemens ST 70 N April 2009 2 g mounting in switchboard 1 g mounted on DIN rail Yes 2 g mounting in switchboard 1 g mounted on DIN rail Yes Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XB0O 6ES7 214 1AE30 0XB0O 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Shock test e Tested in accordance with IEC 60068 2 27 Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen Yes magnitude of shock 15 g peak value duration 11 ms 6 shocks in each of the three mutually perpen dicular axes dicular axes dicular axes Degree of protection IP20 Yes Yes Yes Standards approvals certificates CE mark Yes Yes Yes C TICK Yes Yes Yes cULus Yes Yes Yes FM approval Yes Ye
39. ad memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card 1 MB load memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card 1 MB load memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card Buffering e Available e without battery Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes CPU execution times For bit operations min 0 1 us per operation 0 1 us per operation 0 1 us per operation For word operations min 12 us per operation 12 us per operation 12 us per operation For floating point arithmetic min 18 us per operation 18 us per operation 18 us per operation Data areas and their retentivity Total retentive data area including timers counters bit memories max 2048 byte 2048 byte 2048 byte Address range I O address range e Total I O address range 1024 byte for inputs 1024 byte for inputs 1024 byte for inputs 1024 byte for outputs 1024 byte for outputs 1024 byte for outputs e Inputs 1024 byte 1024 byte 1024 byte e Outputs 1024 byte 1024 byte 1024 byte Digital channels e Integrated channels DI 6 6 6 e Integrated channels DO Analog channels e Integrated channels Al 2 2 2 Siemens ST 70 N Ap
40. al WinCC Basic It is thus possible to use the full performance of these systems sim ply and conveniently with just one tool STEP 7 Basic can be used for e Programming of the SIMATIC S7 1200 controller family CPU 1211C CPU 1212C CPU 1214C z e Configuration of the PROFINET based SIMATIC HMI Basic Panels KTP400 Basic KTP600 Basic mono and KTP600 Basic color KTP1000 Basic TP1500 Basic KTP400 Basic and KTP600 Basic can also be configured for upright mounting LLES CEEE TETEE ey rus tiie tie Ti 4 gyeuruey STEP 7 Basic project view The STEP 7 Basic software is the engineering system for pro gramming the SIMATIC S7 1200 The WinCC Basic engineering system included in the package additionally allows configura tion of SIMATIC HMI Basic Panels on the S7 1200 STEP 7 Basic thus provides support in all phases of the automa tion project e Configuring and parameterizing the hardware e Specifying the communication e Programming in LAD Ladder Diagram and FBD Function Block Diagram Configuration of the visualization e Test commissioning and service 5 2 Siemens ST 70 N April 2009 Siemens AG 2009 Software STEP 7 Basic a Function E Technical specifications Device amp network configuration e Clear configuration of network and device functionalities in specialized views of the editor e Device view photorealistic representation and configuration of
41. ard slot No No No No No USB No No No No No Ethernet 1 x Ethernet RJ45 1x Ethernet RJ45 1x Ethernet RJ45 1x Ethernet RJ45 1 x Ethernet RJ45 Operating systems Operating system LINUX LINUX Processor Processor RISC 32 bit 75 RISC 32 bit 75 MHz RISC 32 bit 75 MHz RISC 32 bit RISC 32 bit 200 Functionality under WinCC flexible Applications options None None None None None Number of Visual Basic scripts Not possible Not possible Not possible Not possible Not possible Task planner Yes Yes Yes Yes Yes 4 4 Siemens ST 70 N April 2009 Siemens AG 2009 Operator control and monitoring Basic Panels E Technical specifications continued 6AV6 647 0AA11 6AV6 647 0AB11 6AV6647 0AD11 6AV6 647 0AF11 6AV6 647 0AG11 3AX0 3AX0 3AX0 3AX0 3AX0 Product name SIMATIC KTP400 SIMATIC KTP600 SIMATIC KTP600 SIMATIC KTP1000 SIMATIC TP1500 Basic mono PN Basic mono PN Basic color PN Basic color PN Basic color PN Help system Yes Yes Yes Yes Yes Status control Not possible Not possible Not possible Not possible Not possible Message system e Number of messages 200 200 200 200 200 e Bit messages Yes Yes Yes Yes Yes e Analog messages Yes Yes Yes Yes Yes e Message buffer Message buffer n x 256 entries non retentive Message buffer n x 256 entries non retentive Message buffer n x 256 entries non retentive Message buffer n x 256 entries non retentive Message buffer n x 256
42. arge test voltage with contact discharge Yes 8 kV 6 kV Yes 8 kV 6 kV Yes 8 kV 6 kV Immunity to conducted interference e on the supply lines in accordance with IEC 61000 4 4 e Immunity on supply lines in accor dance with IEC 61000 4 4 Yes Yes Yes Yes Yes Yes Immunity to surge voltages e on the supply lines in accordance with IEC 61000 4 5 Yes Yes Yes Immunity to conducted interfer ence induced by high frequency fields e Immunity to high frequency irradia tion in accordance with IEC 61000 4 6 Yes Yes Yes Emission of radio interference in accordance with EN 55 011 e Emission of radio interference in accordance with EN 55 011 limit class A Yes Group 1 Yes Group 1 Yes Group 1 Siemens ST 70 N April 2009 2 21 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XBO 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Climatic and mechanical condi tions for storage and transport Climatic conditions for storage and transport e Free fall max height of fall in packaging e Temperature permissible temperature range e Relative humidity permissible range without con densation at 25 C 0 3 m five times in transport pack 0 3 m five times in
43. d special commands for high speed I Programming counters open up new application areas for the user e Interrupt processing The STEP 7 Basic programming package permits complete pro edge triggered interrupts activated by rising or falling gramming of all S7 1200 controllers and the associated I O edges of process signals on interrupt inputs support a rapid response to process events E Technical specifications Test and diagnostics functions Easy to use functions support testing and diagnostics e g 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XBO 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Product version Associated programming package STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Supply voltages Rated value e 24V DC Yes Yes e 120 VAC Yes e 230 V AC Yes e Lower limit of permissible range 20 4 V 20 4 V DC e Upper limit of permissible range 28 8 V 28 8 V DC e Lower limit of permissible range 85 V AC e Upper limit of permissible range 264 V AC e Lower limit of permissible frequen 47 Hz cy range e Upper limit of permissible frequen 63 Hz cy range Load voltage L e Rated value DC 24V 24V 24V e Lower limit of permissible range 5V 20 4 V 5V DC e Upper limit of permissible range 250 V 28 8 V 250 V DC 2 16 Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications contin
44. e g online offline diagnostics Freeport user friendly functions such as pulse width modulation e Forcing of inputs and outputs during testing and diagnostics pulse sequence function arithmetic functions floating point Inputs and outputs can be set independently of cycle and thus arithmetic PID closed loop control jump functions loop permanently for example to test the user program functions and code conversions e Motion Control in accordance with PLCopen for simple mathematical functions e g SIN COS TAN LN EXP movements e Counting e Library functionality User friendly counting functions in conjunction with the integrated counters and special commands for high speed Mecasanming 8 8 Programming counters open up new application areas for the user e Interrupt processing The STEP 7 Basic programming package permits complete pro edge triggered interrupts activated by rising or falling gramming of all S7 1200 controllers and the associated I O edges of process signals on interrupt inputs support a rapid response to process events E Technical specifications 6ES7 211 1BD30 0XB0 6ES7 211 1AD30 0XB0 6ES7 211 1HD30 0XB0 Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Product version Associated programming package STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Supply voltages Rated value e 24V DC Yes Yes e 120 VAC Yes e 230 V AC Yes e Lower limit of permis
45. e of pulse outputs with ohmic load 1 Hz 100 kHz 1 Hz max Cable length e Max cable length shielded 500 m 500 m 500 m e Max cable length unshielded 150 m 150 m 150 m Relay outputs Number of relay outputs 10 10 Number of operating cycles Mechanically 10 million Mechanically 10 million with rated load voltage 100000 with rated load voltage 100000 Analog inputs Number of analog inputs 2 2 2 Max cable length shielded 10 m twisted and shielded 10 m twisted and shielded 10 m twisted and shielded Input ranges e Voltage Yes Yes Yes Input ranges rated values voltages e0 10V e Input resistance 0 10 V Yes 2100 kOhm Yes gt 100 kOhm Yes 2100 kOhm Analog value generation Integration and conversion time resolution per channel e Resolution with overrange bits including sign max e Integration time can be parame terized e Conversion time per channel 10 bit Yes 625 us 10 bit Yes 625 us 10 bit Yes 625 us Analog value generation in isochronous mode Cable length e Max cable length shielded 10 m twisted 10 m twisted 10 m twisted Encoder supply 24 V encoder supply e 24V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V Encoders Connectable encoders e 2 wire BEROs 2 30 Yes Siemens ST 70 N April 2009 Yes Yes Siemens AG 2009 SIMATIC S7
46. ed 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XBO 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Digital inputs Number of digital inputs e Inputs which can be used for tech nological functions 8 integrated 4 HSC high speed counting 8 integrated 4 HSC high speed counting 8 integrated 4 HSC high speed counting Current sourcing sinking Yes Yes Yes Concurrently controllable inputs e All mounting positions concurrently controllable inputs 8 8 8 up to 40 C Input voltage e Rated value DC 24V 24V 24V e for O signal 5 VDC at 1 mA 5 V DC at 1 mA 5 VDC at 1 mA e for 1 signal 15 V DC at 2 5 mA 15 V DC at 2 5 mA 15 V DC at 2 5 mA Input current e for 1 signal typ 1 mA 1 mA 1 mA Input delay at rated value of input voltage or standard inputs programmable for O to 1 min for O to 1 max e For alarm inputs programmable e For counter technological functions programmable 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 0 2 0 4 0 8 1 6 3 2 6 4 and 12 8 ms selectable in groups of 4 0 2 ms 12 8 ms Yes Single phase 3 at 100 kHz 1 at 30 kHz 1 at 30 kHz 1 at 30 kHz Dif
47. ersion time resolution per channel e Resolution with overrange bits including sign max e Integration time can be parame terized e Conversion time per channel 10 bit Yes 625 us 10 bit Yes 625 us 10 bit Yes 625 us Analog value generation in isochronous mode Cable length e Max cable length shielded 10 m twisted 10 m twisted 10 m twisted Encoder supply 24 V encoder supply e 24V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V Encoders Connectable encoders e 2 wire BEROs 2 10 Yes Siemens ST 70 N April 2009 Yes Yes Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Integrated functions Number of counters 3 3 3 ax counter frequency 100 kHz 100 kHz 100 kHz Frequency meters Yes Yes Yes Controlled positioning Yes Yes Yes PID controllers Yes Yes Yes Number of alarm inputs 4 4 4 Number of pulse outputs 2 Limit frequency pulse 100 kHz Operator control and monitoring Display e Integrated No No No Galvanic isolation Galvanic isolation of digital inputs e Galvanic isolation of digital inputs e Between the channels in groups of 500 V
48. ferential 3 at 80 kHz Differential 3 at 80 kHz Differential 3 at 80 kHz 1 at 30 kHz 1 at 30 kHz 1 at 30 kHz Cable length e Max cable length shielded 500 m 500 m 500 m 50 m for technological functions 50 m for technological functions 50 m for technological functions e Max cable length unshielded 300 m 300 m 300 m for technological functions No for technological functions No for technological functions No Digital outputs Number of digital outputs e of those as fast outputs 6 relays 6 relays 2 100 kHz pulse train output 6 relays Short circuit protection No to be provided externally No to be provided externally No to be provided externally Voltage induced on current interrup tion limited to L 48 V Switching capacity of outputs e with ohmic load max e with lamp load max 2A 30 W DC 200 W AC O5A 5W 2A 30 W DC 200 W AC Output voltage e for O signal DC max 0 1 V with 10 kOhm load e for 1 signal min 20 V Output current e for 1 signal rated value 0 5A e for O signal residual current max 0 1 mA Siemens ST 70 N April 2009 219 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XB0O 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Output delay with ohm
49. ic load e O to 1 max 10 ms max 1 us 10 ms max e 1 to 0 max 10 ms max 5 us 10 ms max Switching frequency e of pulse outputs with ohmic load 1 Hz 100 kHz 1 Hz max Cable length e Max cable length shielded 500 m 500 m 500 m e Max cable length unshielded 150 m 150 m 150 m Relay outputs Number of relay outputs 6 6 Number of operating cycles Mechanically 10 million with rated Mechanically 10 million with rated load voltage 100000 load voltage 100000 Analog inputs Number of analog inputs 2 2 2 ax cable length shielded 10 m twisted and shielded 10 m twisted and shielded 10 m twisted and shielded nput ranges e Voltage Yes Yes Yes nput ranges rated values voltages 0 4 10V e Input resistance 0 10 V Yes gt 100 kOhm Yes gt 100 kOhm Yes 2100 kOhm Analog value generation Integration and conversion time resolution per channel e Resolution with overrange bits including sign max e Integration time can be parameter ized e Conversion time per channel 10 bit Yes 625 us 10 bit Yes 625 us 10 bit Yes 625 us Analog value generation in isochronous mode Cable length e Max cable length shielded 10 m twisted 10 m twisted 10 m twisted Encoder supply 24 V encoder supply e 24V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V Permissible range 20 4 28 8 V
50. lors 1 Ethernet interface TCP IP Touch screen e No slot for SD CF MultiMedia Card no USB interface E Function e Permanent window and template concept for creating screen templates e input output fields for displaying and modifying process parameters e Buttons are used for direct triggering of functions and actions Up to 16 functions can be configured simultaneously on buttons e Graphics can be used as icons instead of text to label function keys or buttons They can also be used as full screen background images The configuration tool contains a library with extensive graphics and diverse objects All editors with an OLE interface can be used as graphics editors e g PaintShop Designer or CorelDraw etc e Vector graphics Simple geometric basic forms line circle and rectangle can be created direct in the configuring tool e Fixed texts for labeling function keys process images and process values in different font sizes e Curve functions and bars are used for graphical display of dynamic values e Language switching 5 online languages 32 configuration languages including Asian and Cyrillic character sets Language dependent texts and graphics e User administration Security in accordance with the require ments of the different sectors Authentication with user ID and password User group specific rights E Function continued e Signaling system Discrete alarms Analog messages Freely defi
51. nable message classes e g status fault messages for defining acknowledgment response and displaying message events Message history e Recipe management e Help texts for process screens messages and variables e Arithmetic functions e Limit value monitoring for reliable process control of inputs and outputs e Indicator light for indicating machine and plant statuses e Task planner for cyclic execution of functions e Template concept Siemens AG 2009 Operator control and monitoring Basic Panels Backup restore of configuration operating system and firmware on a PC using ProSave Configuration download via MPI PROFIBUS DP or Ethernet Automatic transfer identification Individual contrast setting and calibration Clean screen No battery required Configuration The configuration is implemented using the engineering software SIMATIC WinCC flexible 2008 Compact or WinCC Basic V10 5 which is part of STEP 7 Basic V10 5 for PROFINET based devices only a Integration The Basic Panels can be connected to e SIMATIC S7 controllers e Non Siemens controllers applies for DP devices Allen Bradley DF1 Modicon Modbus e Creation of picture templates picture elements configured in the template appear in every image e Simple maintenance and configuration thanks to E Technical specifications Note Further information can be found under System interfaces 6AV6 647 0AA11 6AV6 6
52. ng e Interrupt processing The STEP 7 Basic programming package permits complete pro edge triggered interrupts activated by rising or falling gramming of all S7 1200 controllers and the associated I O edges of process signals on interrupt inputs support a rapid response to process events E Technical specifications 6ES7 214 1BE30 0XB0 6ES7 214 1AE30 0XB0 6ES7 214 1HE30 0XB0 Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Product version Associated programming package STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Supply voltages Rated value e 24V DC Yes Yes e 120 VAC Yes e 230 V AC Yes e Lower limit of permissible range 20 4 V 20 4 V DC e Upper limit of permissible range 28 8 V 28 8 V DC e Lower limit of permissible range 85V AC e Upper limit of permissible range 264 V AC e Lower limit of permissible 47 Hz frequency range e Upper limit of permissible 63 Hz frequency range Load voltage L e Rated value DC 24V 24V 24V e Lower limit of permissible range 5V 20 4 V 5V DC e Upper limit of permissible range 250 V 28 8 V 250 V DC 2 26 Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XBO 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Current co
53. nsfer recognition Ethernet automatic transfer recognition Ethernet automatic transfer recognition Process coupling e Connection to controller S7 200 S7 300 400 WinAC PC TCP IP see Catalog ST 80 7 200 S7 300 400 WinAC PC TCP IP see Catalog ST 80 7 200 S7 300 400 WinAC PC TCP IP see Catalog ST 80 7 200 S7 300 400 WinAC PC TCP IP see Catalog ST 80 7 200 S7 300 400 WinAC PC TCP IP see Catalog ST 80 Expandability openness e Open Platform Program No No No No No Dimensions Front of enclosure W x H 140 mm x 116 mm 214mm x 158 mm 214mm x 158 mm 335 mm x 275 mm 400 mm x 310 mm Mounting cutout Device depth W x H D in mm 123 mm x 99 mm 40 mm device depth 197 mm x 141 mm 44 mm device depth 197 mm x 141 mm 44 mm device depth 310 mm x 248 mm 60 mm device depth 367 mm x 289 mm 60 mm device depth Dimensions and weight Weight e Weight 4 6 0 33 kg Siemens ST 70 N April 2009 KO 1 1 kg 2 5kg 4 2 kg Siemens AG 2009 Operator control and monitoring Basic Panels E Ordering data Order No Order No SIMATIC KTP400 Basic mono E 6AV6 647 0AA11 3AX0 PN Starter kit for SIMATIC KTP400 A 6AV6 652 7AA01 3AA0 Basic mono PN SIMATIC KTP600 Basic mono E 6AV6 647 0AB11 3AX0 PN Starter kit for SIMATIC KTP600 A 6AV6 652 7BA01 3AA0 Basic mono PN SIMATIC KTP600 Basic col
54. nsumption Current consumption rated value 100 mA at 120 V AC 50 mA at 240 V AC 500 mA typically Current consumption max 300 mA at 120 V AC 1 5 A 24 V DC 1 2 A 24 V DC 150 mA at 240 V AC Max starting current 20 A at 264 V 12 A at 28 8 V 12 A at 28 8 V Current output at backplane bus 1600 mA 1600 mA 1600 mA 5 V DC max max 5 V DC for SM and CM max 5 V DC for SM and CM max 5 V DC for SM and CM Current consumption power loss Power loss typ 14W 12W 12W Memory Usable memory for application data 50 kbyte 50 kbyte 50 kbyte Work memory e Integrated 50 kbyte 50 kbyte 50 kbyte e Expandable No No No Load memory e Integrated e Expandable max 2 Mbyte load memory expandable using SIEMENS Memory Card 24 Mbyte with SIEMENS Memory Card 2 Mbyte load memory expandable using SIEMENS Memory Card 24 Mbyte with SIEMENS Memory Card 2 Mbyte load memory expandable using SIEMENS Memory Card 24 Mbyte with SIEMENS Memory Card Buffering e Available e Without battery Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes CPU execution times for bit operations min 0 1 us per operation 0 1 us per operation 0 1 us per operation for word operations min 12 us per operation 12 us
55. or E 6AV6 647 0AD11 3AX0 PN Starter kit for SIMATIC KTP600 A 6AV6 652 7DA01 3AA0 Basic color PN SIMATIC KTP1000 Basic color E 6AV6 647 0AF11 3AX0 PN Starter kit for SIMATIC KTP1000 A 6AV6 652 7FA01 3AA0 Basic color PN SIMATIC TP1500 Basic color E 6AV6 647 0AG11 3AX0 PN Starter kits consist of e the relevant SIMATIC KTP Basic Panel e SIMATIC WinCC flexible Compact engineering software e SIMATIC HMI Manual Collection DVD 5 languages English French German Italian Spanish comprising all currently available user manuals manuals and communication manuals for SIMATIC HMI e Ethernet cable on PN devices e MPI cable on DP devices for download and test purposes only e Voucher for Software Update Service for 1 year A Subject to export regulations AL N and ECCN 5D992 D Subject to export regulations AL N and ECCN EAR99S Configuration e all devices with SIMATIC WinCC flexible Compact e PROFINET based devices with WinCC Basic V10 5 part of STEP 7 Basic V10 5 See Catalog ST 80 See Catalog ST 80 Documentation to be ordered separately You can find the manual for the Basic Panels on the Internet at http support automation siemens com User Manual WinCC flexible Compact Standard Advanced e German 6AV6 691 1AB01 3AA0 e English 6AV6 691 1AB01 3AB0 e French 6AV6 691 1AB01 3AC0 e Italian 6AV6 691 1AB01 3AD0 e Spanish 6AV6 691 1AB01 3AE0 User Manual
56. ordered separately ordered separately ordered separately Display Display type STN gray scales STN gray scales TFT 256 colors TFT 256 colors TFT 256 colors Size 3 8 Si S 10 4 15 Resolution W x H in pixel 320 x 240 320 x 240 320 x 240 640 x 480 1024 x 768 e MTBF backlighting at 25 C about 30 000 h about 50 000 h about 50 000 h about 50 000 h about 50 000 h Siemens ST 70 N April 2009 4 3 Basic Panels Siemens AG 2009 Operator control and monitoring D Technical specifications continued 6AV6 647 0AA11 3AX0 6AV6 647 0AB11 3AX0 6AV6 647 0AD11 3AX0 6AV6 647 0AF11 3AX0 6AV6 647 0AG11 3AX0 Product name SIMATIC KTP400 Basic mono PN SIMATIC KTP600 Basic mono PN SIMATIC KTP600 Basic color PN SIMATIC KTP1000 Basic color PN SIMATIC TP1500 Basic color PN Operating mode Operating elements Membrane keyboard Membrane keyboard Membrane keyboard Membrane keyboard Touchscreen Function keys programmable 4 function keys 6 function keys 6 function keys 8 function keys none Connection for j afefe mouse keyboard barcode reader e Touchscreen analog resistive analog resistive analog resistive analog resistive analog resistive e Numeric alphabetical input Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Ambient conditions Mounting position vertical vertical vertical vertical vertical maximum permissible angle of
57. pply lines in accordance with IEC 61000 4 4 e Immunity on supply lines in accor dance with IEC 61000 4 4 Yes Yes Yes Yes Yes Yes Immunity to surge voltages e on the supply lines in accordance with IEC 61000 4 5 Yes Yes Yes Immunity to conducted inter ference induced by high frequency fields e Immunity to high frequency irradiation in accordance with IEC 61000 4 6 Yes Yes Yes Emission of radio interference in accordance with EN 55 011 e Emission of radio interference in accordance with EN 55 011 limit class A Yes Group 1 Yes Group 1 Yes Group 1 Siemens ST 70 N April 2009 2131 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 214 1BE30 0XBO 6ES7 214 1AE30 0XB0O 6ES7 214 1HE30 0XBO Product name CPU 1214C AC DC relay CPU 1214C DC DC DC CPU 1214C DC DC relay Climatic and mechanical condi tions for storage and transport Climatic conditions for storage and transport e Free fall max height of fall in packaging e Temperature permissible temperature range e Relative humidity permissible range without condensation at 25 C 0 3 m five times in transport packaging 40 C 70 C 95 0 3 m five times in transport packaging 40 C 70 C 95 0 3 m five times in transport packaging 40 C 70 C 95
58. rator panels programming devices other controllers or the office world The CSM 1277 and the SIMATIC S7 1200 controller can be used to implement simple automation networks at low cost 3 4 Siemens ST 70 N April 2009 Siemens AG 2009 Communication CSM 1277 unmanaged E Technical specifications 6GK7 277 1AA00 0AA0 6GK7 277 1AA00 0AA0 Product name CSM 1277 Product name CSM 1277 Transfer rate 1 10 Mbit s Input current 70 mA Transfer rate 2 100 Mbit s Effective power loss 1 1W Number of electrical connec eat 24V DC 1 6 W tions e maximum storsignaling contol i Ambient temperature i oe components or 4 e during operation 0 C 60 C e for power supply 1 e during storage 40 C 70 C Electrical connection version e during transport 40 C 70 C e for signaling contact r e at 95 e for network components or RJ45 socket terminals e for power supply 3 pole terminal block Construction type SIMATIC S7 1200 device design Power supply 24 V DC e maximum 28 2 V e minimum 19 2 V Width 45 mm Height 100 mm Depth 76mm Net weight 150 g Type of fixing 7 1200 mounting rail wall mounting IP degree of protection IP20 Ej Ordering data Order No Order No CSM 1277 compact switch module Unmanaged switch for connecting a SIMATIC S7 1200 and up to three further nodes to Industrial Ethernet with 10 100 Mbit s 4 x RJ45 ports external 24 V
59. ril 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Hardware configuration Number of modules per system 3 communication modules 1 signal 3 communication modules 1 signal 3 communication modules 1 signal max board board board Time Clock e Hardware clock real time clock Yes Yes Yes e Buffered period 240 h typically 240 h typically 240 h typically e Deviation per day max 60 s month at 25 C 60 s month at 25 C 60 s month at 25 C Test and startup functions Status control e Status modify variable Yes Yes Yes e Tags Inputs outputs bit memories DBs Inputs outputs bit memories DBs Inputs outputs bit memories DBs distributed inputs outputs timers distributed inputs outputs timers distributed inputs outputs timers counters counters counters Forcing e Forcing Yes Yes Yes Communications functions S7 communication e Supported Yes Yes Yes e As server Yes Yes Yes e As client Yes Yes Yes Open IE communication e TCP IP Yes Yes Yes e ISO on TCP RFC1006 Yes Yes Yes Number of connections e Total 16 16 dynamic 16 1st interface Type of interface PROFINET PROFINET PROFINET Physics Ethernet Ethernet Ethernet I
60. rnet interface TCP IP native ISO on TCP 6 fast counters 3 with max 100 kHz 3 with max 30 kHz with parameterizable enable and reset inputs can be used simul taneously as up and down counters with 2 separate inputs or for connecting incremental encoders Expansion by additional communication interfaces e g RS485 or RS232 Expansion by analog or digital signals directly on the CPU via signal board with retention of CPU mounting dimensions Expansion by a wide range of analog and digital input and output signals via signal modules Optional memory expansion SIMATIC Memory Card PID controller with auto tuning functionality Integral real time clock Interrupt inputs For extremely fast response to rising or falling edges of process signals Removable terminals on all modules Simulator optional For simulating the integrated inputs and for testing the user program Device versions Version Supply voltage Input voltage DI e DC DC DC 24V DC 24V DC e DC DC relay 24 V DC 24V DC e AC DC relay 85 264 V AC 24V DC Output voltage DO Output current 24V DC 0 5 A Transistor 5 a 610 W IDG j 2A 5 250 V AC 30 Watt DC 200 Watt AC 5 30VDC 2A 5 250 V AC 30 Watt DC 200 Watt AC Siemens ST 70 N April 2009 2 25 Siemens AG 2009 SIMATIC S7 1200 Central processing units tian i time triggered interrupts Function counter interrupts can be triggered when a se
61. s blocks etc for system based project analysis or trouble shooting e Automatic generation of connections when using the control variables in the HMI e Global and local libraries for simple repeated use of precon figured elements e Intelligent drag amp drop for importing and interconnecting data from different editors Online diagnostics e Clear representation of module diagnostics information e Monitoring tables with Force and Control facilities e Automatic display of all nodes accessible in the network e Detailed comparison between online and offline projects STEP 7 Basic Single License Licensing form Software class A V10 5 SIMATIC S7 1200 Windows XP Professional SP3 32 bit Windows Vista Ultimate SP1 32 bit Windows Vista Business SP1 32 bit Windows Vista Home Premium SP1 Current version Target system Operating system 32 bit Main memory size in 1GB programming device PC min Disk memory requirement in 2 GB programming device PC Remark Includes the IEC programming languages LAD and FBP E Ordering data Order No STEP 7 Basic V10 5 Target system SIMATIC S7 1200 SIMATIC HMI Basic Panels Requirement Windows XP SP3 Vista Ultimate SP1 Vista Business SP1 Home Premium SP1 Type of delivery German English STEP 7 Basic V10 5 on DVD Software Update Service requires current software version D Subject to export regulations AL N and
62. s Yes Dimensions and weight Dimensions and weight e Width 110 mm 110 mm 110 mm e Height 100 mm 100 mm 100 mm e Depth 75mm 75mm 75mm Weight e Approx weight 455 g 415g 435g Siemens ST 70 N April 2009 2 33 SIMATIC S7 1200 Central processing units a Ordering data Order No Order No Siemens AG 2009 CPU 1214C Compact CPU AC DC relay C 6ES7 214 1BE30 0XBO integral program data memory 50 KB load memory 2 MB wide range power supply 85 264 V AC Boolean execution times 0 1 us per operation 14 digital inputs 10 digital outputs relays 2 analog inputs expandable by up to 3 communication modules 8 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz Compact CPU DC DC DC C 6ES7 214 1AE30 0XBO integral program data memory 50 KB load memory 2 MB power supply 24 V DC Boolean execution times 0 1 us per operation 14 digital inputs 10 digital outputs relays 2 analog inputs expandable by up to 3 communication modules 8 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz 24 V DC digital outputs can be used as pulse outputs PTO or pulse width modulated outputs PWM with 100 kHz Compact CPU DC DC relay C 6ES7 214 1HE30 0XBO integral program data memory 50 KB load memory 2 MB power supply 24 V DC Boolean execution times 0 1 us per operation 14 digital inputs 10 digital outputs 2 analog inputs expandable b
63. sible range 20 4 V 20 4 V DC e Upper limit of permissible range 28 8 V 28 8 V DC e Lower limit of permissible range 85 V AC e Upper limit of permissible range 264 V AC e Lower limit of permissible 47 Hz frequency range e Upper limit of permissible 63 Hz frequency range Load voltage L e Rated value DC 24V 24V e Lower limit of permissible range 20 4 V 20 4 V DC e Upper limit of permissible range 28 8 V 28 8 V DC Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Current consumption Current consumption rated value 60 mA at 120 VAC 300 mA typically 300 mA typically 30 mA at 240 V AC Current consumption max 180 mA at 120 VAC 0 9 A 24 V DC 0 9 A 24 V DC 90 mA at 240 V AC Max starting current 20 A at 264 V 12 A at 28 8 V 12 A at 28 8 V Current output at backplane bus 750 mA max 5 V DC forSMand 750mA max 5VDCforSMand 750 mA max 5 V DC for SM and 5 V DC max CM CM CM Current consumption power loss Power loss typ 10 W 8W 8W Memory Usable memory for application data 25 KB 25 KB 25 KB Work memory Integrated 25 KB 25 KB 25 KB e Expandable No No No Load memory e Integrated e Expandable max 1 MB lo
64. solated Yes Yes Yes Automatic determination of transfer Yes Yes Yes rate Autonegotiation Yes Yes Yes Autocrossover Yes Yes Yes CPU programming Configuring software e STEP 7 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 STEP 7 Basic V 10 5 Programming language e LAD Yes Yes Yes e FBD Yes Yes Yes e STL Cycle time monitoring e Configurable Yes Yes Yes Siemens ST 70 N April 2009 Siemens AG 2009 SIMATIC S7 1200 Central rocessing units a Technical specifications continued 6ES7 211 1BD30 0XBO 6ES7 211 1AD30 0XBO 6ES7 211 1HD30 0XBO Product name CPU 1211C AC DC relay CPU 1211C DC DC DC CPU 1211C DC DC relay Digital inputs Number of digital inputs e Inputs which can be used for technological functions 6 integrated 3 HSC high speed counting 6 integrated 3 HSC high speed counting 6 integrated 3 HSC high speed counting Current sourcing sinking Yes Yes Yes Concurrently controllable inputs e All mounting positions concurrently controllable inputs 6 6 6 up to 40 C Input voltage e Rated value DC 24V 24V 24V e for O signal 5 VDC at 1 mA 5 V DC at 1 mA 5 VDC at 1 mA e for 1 signal 15 V DC at 2 5 mA 15 V DC at 2 5 mA 15 V DC at 2 5 mA Input current e for 1 signal typ 1 mA 1 mA 1 mA Input delay at rated value of input voltage or standard inputs programmable for O to 1 min for 0 to 1 max e for alarm
65. t status display via LEDs on the device e Connection of SIMATIC S7 1200 in linear topology At least one RJ45 connection of the SIMATIC S7 1200 remains vacant e g for connecting a programming device PG e Connection of SIMATIC S7 1200 to a higher level network in a Wsencits tree star topology enefits At least two RJ45 connections of the SIMATIC S7 1200 remain vacant e g for connecting a programming device operator panel PG OP get Designed for Industry e Design of a small local network with a SIMATIC S7 1200 and three further Ethernet nodes e Integral autocrossover function permits use of uncrossed connecting cables e Reduction in assembly costs and mounting space compared to use of external network components Configuration e Multiplication of Ethernet interfaces on a SIMATIC S7 1200 for The CSM 1277 compact switch module is an unmanaged switch additional connection of programming devices operator and need not be configured controls and further Ethernet nodes e Lowest cost solution for implementing small local Ethernet Diagnostics networks with a SIMATIC S7 1200 The following information is displayed on LEDs on the device e Power Application e Port status The CSM 1277 is an Industrial Ethernet switch of compact and e Data traffic modular design for use in the SIMATIC S7 1200 The CSM 1277 can be used to multiply the Ethernet interface of the SIMATIC S7 1200 in order to allow simultaneous communication with ope
66. the hardware modules clipboard for modules for simple intermediate storage of respective module parameters catalog includes all panels CPUs and modules with firmware versions e Network view clear total view of all devices and network components used intelligent drag amp drop function for generation of connections Controller programming e Powerful editors for programming the S7 1200 in LAD and FBP comprehensive catalog of instructions configurable favorites area for frequently used instructions table based editor for configuration of block interfaces intellisense for support during selection of tags simple reuse of instructions or networks within a project e Motion and technology functionalities system support for integrated technology functions such as Speed controlled axis and Positioning axis PID controller with self optimization autotuning Visualization e Powerful editors for configuration of Basic Panel functionalities operating screens with touch key operation and trend vector graphics bit and analog alarms recipe management e Multi language up to 5 languages online e Graphics library with off the shelf picture objects e Intelligent drag amp drop for efficient configuration of standard functionalities Integration e Integrated symbolic programming e Direct use of control variables in the HMI to avoid multiple inputs e Common cross reference list for configuration objects tag
67. tpoint is e Comprehensive instruction set reached or when the direction of counting changes A wide range of operations facilitate programming communication interrupts allow the rapid and easy basic operations such as binary logic operations result exchange of information with peripheral devices such as allocation save count create times load transfer printers or bar code readers compare shift rotate create complement call subprogram e Password protection with local variables integral communication commands e g USS protocol e Test and diagnostics functions Modbus RTU 7 communication T Send T Receive or Easy to use functions support testing and diagnostics e g Freeport online offline diagnostics user friendly functions such as pulse width modulation e Forcing of inputs and outputs during testing and diagnostics pulse sequence function arithmetic functions floating point Inputs and outputs can be set independently of cycle and thus arithmetic PID closed loop control jump functions loop permanently for example to test the user program functions and code conversions e Motion Control in accordance with PLCopen for simple mathematical functions e g SIN COS TAN LN EXP movements e Counting e Library functionality User friendly counting functions in conjunction with the integrated counters and special commands for high speed B Proarammina counters open up new application areas for the user Programmi
68. transport pack aging 40 C 70 C 95 aging 40 C 70 C 95 0 3 m five times in transport pack aging 40 C 70 C 95 Mechanical and climatic condi tions in operation Climatic conditions in operation e Temperature permissible temperature range permissible temperature change e Atmospheric pressure acc to IEC 60068 2 13 permissible atmospheric pres sure permissible operating altitude e Concentration of pollutants SO at RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m S05 lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m S0 lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation 0 C 55 C horizontal mounting 0 C 45 C vertical mounting 5 C 55 C 3 C minute 1080 795 hPa 1000 m 2000 m SOs lt 0 5 ppm H2S lt 0 1 ppm RH lt 60 without condensation Environmental requirements Operating temperature e Min 0 C 0 C 0 C e Max 15 IC Some 591C e Vertical installation min 0 C One 0 C e Vertical installation max 45 C 45 C 45 C e Horizontal installation min 0 C 0 C 0 C e
69. ued 6ES7 212 1BD30 0XBO 6ES7 212 1AD30 0XB0O 6ES7 212 1HD30 0XBO Product name CPU 1212C AC DC relay CPU 1212C DC DC DC CPU 1212C DC DC relay Current consumption Current consumption rated value 80 mA at 120 VAC 175 mA typically 40 mA at 240 VAC Current consumption max 240 mA at 120 VAC 1 2 A 24V DC 1 2 A 24V DC 120 mA at 240 VAC Max starting current 20 A at 264 V 12 A 28 8 V DC 12 A at 28 8 V Current output at backplane bus 1000 mA max 5 V DC for SM and 1000 mA max 5 VDC for SM and 1000 mA max 5 V DC for SM and 5 V DC max CM CM CM Current consumption power loss Power loss typ 11W 9 W 9 W Memory Usable memory for application data 25 KB 25 KB 25 KB Work memory e Integrated 25 KB 25 KB 25 KB e Expandable No No No Load memory e Integrated e Expandable max 1 MB load memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card 1 MB load memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card 1 MB load memory expandable using SIEMENS Memory Card 24 MB with SIEMENS Memory Card Buffering e Available e Without battery Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes Yes complete project maintenance free in the integral EEPROM Yes CPU execution times for bit operations min 0 1 us
70. y up to 3 communication modules 8 signal modules and 1 signal board digital inputs can be used as HSC at 100 kHz C Subject to export regulations AL N and ECCN EAR99H E More information Brochures Information material for downloading can be found in the Internet http www siemens com simatic printmaterial 2 34 Siemens ST 70 N April 2009 SB 1223 signal board C 6ES7 223 0BD30 0XB0 2 inputs 24 V DC IEC type 1 current sinking two 24 V DC transistor outputs 0 5 A 5 W can be used as HSC at up to 30 kHz SB 1232 signal board C 6ES7 232 4HA30 0XB0 1 analog output 10 V with 12 bit or 0 20 mA with 11 bit Simulator optional Cc 14 input switches for CPU 1214C 6ES7 274 1XH30 0XA0 SIMATIC Memory Card optional 2 MB C 6ES7 954 8LB00 0AA0 24 MB C 6ES7 954 8LF00 0AA0 7 1200 automation system System Manual for SIMATIC S7 1200 and STEP 7 Basic German 6ES7 298 8FA30 8AHO English 6ES7 298 8FA30 8BHO STEP 7 Basic engineering software Target system SIMATIC S7 1200 controllers and the associated I O The WinCC Basic which is included permits configuration of the SIMATIC Basic Panels Requirement MS Windows XP SP3 MS Windows Vista SP1 Type of delivery German English with online documentation Single license D 6ES7 822 0AA00 0YA0 STEP 7 Basic Software Update D 6ES7 822 0AA00 0YLO Service 1 year D Subject to export regulations AL N and ECCN