Home
BS-6000 TCP/IP Station User Manual
Contents
1. has been started on the server and its server function has been started If the BS 6000 emits two consecutive short beeps while attempting to communicate with the server it means that the Ethernet cable is not properly connected Make sure that the TCP IP server settings on the BS 6000 unit are correct Please contact with the technology support if you can not solve the problem by using above solutions BS 6000 Data Sheet 159x79x33mm Color Dark Grey Connection With Readers Storage Capacity 49713 records Operating temperature 20 C to 70 C Operating humidity 0 to 95 DISCLAIMER The information in this documentation is subjective to change notice and does not represent a commitment on the part of Bluecard Software Technology Co Ltd No part of the this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or information storage and retrieval systems for any purpose other than the purchaser s personal use without the written permission of Bluecard Software Technology Co Ltd All trademarks mentioned in the document belong to their respective owners BlueCard Bluecard Software Technology Co Ltd
2. EESHOOTIN Gilda RIA BS 6000 DA TA SHEE ocni aa a DISCLAIMER 0 a S Description of the BS 6000 hardware Status LED Lights in the descriptions below up indicates the direction on the BS 6000 where the status LED lights are located Red LED Upper Left Flashing Receiving Sending the data by Internet Constant on the BS 6000 has data that needs to be uploaded Constant off the BS 6000 does not have data that needs to be uploaded Green LED Lower Left Flashing once per second the BS 6000 is operating normally Red LED Upper Right Constant on the unit is connected with the Internet Constant off the unit is not connected with the Internet Blue LED Lower Right Flashing once per second the BS 6000 is operating normally Flashing quickly the BS 6000 is calling the target server Audio Signals There are two types of audio signals long beep and short beep Some of the audio signals below have multiple meanings depending on the situation Short Beep once Guard tour reader has been found but the reader does not contain data that needs to be uploaded The local unit has connected successfully with the BS6000 server and set the IP successfully Short Beep twice consecutively Guard tour reader has been found and the reader contains data that needs to be uploaded Short Beep three times consecutively The BS 6000 is failed to calling the target server Short Beep three
3. ENGLISH BlueCard TCP IP Remote Communication Station User s Manual BS 6000 Please read this manual carefully before starting to operate the station CE FE Main Features The BS 6000 is able to upload data collected from guard tour readers over the TCP IP network either intranet or Internet by connecting to an Ethernet RJ45 Cable Prior to deployment the BS 6000 unit needs to be connected to the PC and be setup using the provided software The provided software also acts as the server software transferring data to a stand along or web based software system First Time Usage Before download the data from reader we recommend you to initialize the station to make sure the station does not have any useless records po TABLE OF CONTENT DESCRIPTION OF THE BS 6000 HARDWARE oonnccococcccccoococccoccccccononcccccccnccoconananacccccccncccacccccconono STATS A e a os PTE IC A A NANE Fe OPER TR TOC EOE ET VIE SET NIC OVEN CIEL OPS NA EAE E FPONPR SOU 22 Gal Cie eee eae Te ee ne me me ease ete ae ee Mee RAN OPERATING INSTRU C TIONS cases sensssessaststedsscndeaceseestos deccgeesondeseedataedeesocasessasenseosceaeecscasdsooasnmaceasenseeses INSTALLING TCP IP SERVER UTILITY amp DOWNLOAD INTERNET SETTINGS FROM TCP IP SERVER COLLECTING DATA FROM GUARD TOUR READERS cccccccccccceccceesssssseseecccccccesseeeccuuussssseeeeeeecccsseeeeseuuuansnsssss REMOTE DATA UPLOADS TT STR RW IR LOCALDATA UPLOAD a TROUB
4. g the USB cable provided Start the patrol management software and select the appropriate communication method Open the connect screen in the patrol management software which will automatically collect data from the BS 6000 Troubleshooting After turning on the unit its green and blue LED status lights do not flash This means that the unit was not properly reset Please disconnect its power and reconnect after at least 3 seconds Nothing happens after placing a guard tour reader upon the unit Make sure that the BS 6000 is operating properly and that its LED status lights are flashing correctly Check to see if the reader is placed properly on the unit The reading head of the reader should be between the status lights of the unit and its top should be flush against the inside edge of the unit Please note that the BS 6000 unit is not able to upload data from guard tour readers when it is communicating with the PC or 10 seconds following its most recent communication with the PC During setup when the PC is connected to the BS 6000 via the USB cable the BS 6000 does not respond to Call requests from the software Make sure that the BS 6000 is operating properly and that its LED status lights are flashing correctly Check in Windows Device Manager and make sure that the proper USB driver has been installed for the BS 6000 The BS 6000 is not able to upload data to the server Make sure that the BS 6000 program
5. the BS 6000 gt If there is data that needs to be transferred from the reader to the BS 6000 its blue LED light will start flashing rapidly indicating that data is being transferred When the transfer process is complete the BS 6000 will make one long beep then one short beep periodically every few seconds indicating that the reader connected no longer has any data to upload and should be removed If you have another reader that needs to have its data transferred please place it in the unit at this time gt If the BS 6000 makes three short beeps it means that its memory is full and will need to have it uploaded before being able to collect any more data from readers Remote data upload Please make sure BS 6000 has been connected with the intranet or Internet Once it has data that needs to be uploaded the BS 6000 will automatically attempt to connect and upload to the server This will occur after communication with a reader is complete and also when the BS 6000 is first powered up If it does not succeed on the first attempt it will try again once every 30 seconds for the next 90 seconds Afterwards it will wait for 3 minutes and start trying again every 30 seconds for another 90 seconds The cycle continues until all unuploaded data has been uploaded The red LED next to the green LED will then turn off Local data upload gt BS 6000 is capable of uploading the stored data to the PC directly Connect the unit to the PC usin
6. times in every three seconds The BS 6000 s memory is full and its data needs to be uploaded to the PC first Short Beep three times consecutively One Second Stop Short Beep three times consecutively The comm station has not been registered in the BS 6000 server Long Beep once Short Beep twice The BS 6000 is calling the target server Long Beep three times consecutively Data has been completely transferred via the Internet Long Beep once Short Beep three times The BS 6000 is not operable and needs to be initialized by the manufacturer Power Source The BS 6000 is able to use multiple types of power supplies USB connection to the computer 7 5V AC adapter Car adapter The BS 6000 will turn on automatically after being connected to a power source The status LED lights will start flashing at a normal pace if the unit is operating correctly Operating Instructions Installing TCP IP Server Utility amp Download Internet settings from TCP IP Server Please refer to the TCP IP Server Utility User s Manual for the details on BS 6000 settings Collecting data from guard tour readers Compatible readers include models BP 2002S BP 2002F BP 2002 W and BP 2002B W gt Turn on the BS 6000 gt Set the reader into the indentation on the BS 6000 For reader model BP 2002S please place its reading head between the status lights and set its top flush against the inside edge of