Home
User Manual - Pestgoaway
Contents
1. to warm up 7 Clear the area out to 2 meters in front of the nozzle 8 To start spraying turn the solution tap to the ON position Spraying tips Spray behind you as you walk into the wind Keep nozzle at least 2 meters away from objects To stop spraying 1 Turn the solution tap to CLEAN position This releases the solution pressure clean on 2 Once the spray dies down turn the solution tap to OFF 3 Shut the gas valve by pressing down 4 Empty the solution tank and rinse with clean water 5 Storage If you will not be using the machine for a while 1 Rinse the solution tank using clean water 2 Rinse the solution feed using clean water 3 Remove the batteries 6 Troubleshooting Engine does not start 1 Check fuel tank level Ensure it is 1 3 to 2 3 full 2 Check ignition system Remove the ignition cap and press the cap to the metal body Without touching the metal body start pumping If you can hear a sound like Ta Ta Ta then the ignition system is functioning properly Oth erwise replace the batteries 3 Clean the air intake Take apart the air in take assembly in the back of the machine Clean the spacer plates Use a soft cloth to wipe the diaphragm The engine will not start if the di aphragm is wet 10 4 If the diaphragm was dry skip to the next step If the diaphragm was wet decrease the ac celerator setting See Appendix Through trial and
2. 0L UK2 spezial 2 0L VK1 1 5L Nevolin nevocol 1 5L Fuels and white oils Vegetable Oil 2 5L Diesel Heating Oil 2 0L Kerosene 2 0L Petropal 2 0L Shell Risella 1 5L The special carriers volume must be calculated accurately according to the rooms volume 3 Tech specs Exact specifications depend on altitude and tempera ture Solution flow rate Solution capacity Solution pressure Fuel engine Fuel consumption Fuel capacity Fuel pressure Fuel type Batteries Dimensions Weight empty Flow rates 27 gal hr 1 3 gal 0 2 bar 25 2 hp 0 4 0 5 gal hr 0 4 gal 0 1 bar gasoline 4 x 1 5V 51 4 x 11 4 x 14 2 in 23 4 Ib Exact flow rate depends on carrier viscosity which de pends on temperature Flow rate L h 42 60 65 Flow rate gal h 11 15 6 17 4 Operation First time setup 1 Install 4 x 1 5V batteries into the battery com partment at the base of the nozzle 2 Shut the gas valve by pressing down 3 Check the ignition by pumping You should hear a buzzing sound ta ta ta To start spraying 1 Fill the fuel tank using the included fuel funnel Fill to full capacity Tip Tighten the lid lightly to not damage the rubber seal inside the lid 2 Fill the solution tank using the included solution funnel Fill to about two thirds full clean 4 Open the gas valve by pulling up 5 Gently and slowly push and pull the air pump 6 Wait 1 minute for the unit
3. 5 Clean the nozzle Wait for fogging tube to cool Carefully unscrew the nozzle Clean out any clogs 18 7 Appendix Adjusting the accelerator The notch at the top of the dial points to the cur rent setting here 0 The higher the setting the higher the gas feed rate e Do not use a setting above 4 unless specifi cally instructed e While adjusting stay at least 2 meters away from the front of the unit If the accelerator is too low the engine may not start The accelerator is too high if 19 e You can hear the engine pop noise as you pump the machine or e Gas wets the diaphragm 20 Schematics Page intentionally left blank 21 maL 1 23 24 20
4. LONGRAY User Manual gas valve on off accelerator adjust knob solution drain solution tank fuel tank LR TS75L 02015 Longray All rights reserved Contents 1 Warnings 2 Warnings for indoor operation 3 Tech specs A Bot ee eh 4 Operation First time setup 0004 TO Stanly Spraye mario sa BS a PLAYAS IPS dad Ga eee eo oe amp amp x 1O S 0P Sprave N a Ge ne 5 Storage 6 Troubleshooting Engine does not start Engine starts but does not spray fog 7 Appendix Adjusting the accelerator Schematics 2 0 2 0 ee eee 1 Warnings After spraying use water to clean the solution tank and pipeline This is especially important for corrosive chemicals Strongly corrosive chemicals such as peroxyacetic acid may damage the unit Limit to occasional use Do not use fogger near flammable surroundings Never run the unit in the presence of an open flame Do not leave a running fogger unattended Wear ear protection Some components can get hot while spraying Let the unit cool down before adding more solu tion or fuel Do not transport or pack the unit while it is hot 2 Warnings for indoor operation e In closed spaces operator should wear a breath ing mask e Some aerosol carriers at high concentrations be come flammable Do not exceed these limits per 1000 m Special carriers Nebal 3 0L Glyzerine 2 5L Ekomist 2 0L Ethylengkole 2
5. error find a setting that is low enough that the diaphragm isn t wetted during startup but not so low that the engine won t start You will need to dry the diaphragm in between tests Check and clean swirl pole Unscrew the swirl pole Check that the two needles at the end of the swirl pole are clean sharp edged and symmetrical 11 6 Check one way diaphragm for fitting damage Detach the rubber tube from the diaphragm Inspect the diaphragm 12 Do not re screw the one way diaphragm too tightly 7 Check pump seal for fitting damage 8 Check large rubber O ring for fitting damage 13 9 Clean fogging tube Remove any deposited carbon 10 Check gas injection Remove ignition voltage cap two screws and the swirl pole 14 Insert finger into the swirl pole cavity and begin pumping Increase the accelerator setting until you can feel the gas spray 15 Engine starts but does not spray fog 1 Check solution tank pressure With the en gine running and the solution tap in the ON po sition remove the solution lid and place your palm over the opening If you can feel pressure contact technical sup port If there is no pressure continue to the next step 2 Clean the solution line Remove and clean the connecting screw 16 3 Check the one way diaphragm Detach the rubber tube from the diaphragm Ged 4 Clean the solution filter 17
Download Pdf Manuals
Related Search
Related Contents
Duolink Duolink Duolink Duolink KOMA Elektronik FT201 Analog State Variable Filter / 10 Step Recommended Rules Changes - Sports Car Club of America StarTech.com 304.8m Cat 5e UTP Macom 211 makeup mirror ご使用上のご注意 NOTE DE PRÉSENTATION GLOBALE Manuel d`instructions Copyright © All rights reserved.
Failed to retrieve file