Home
NX User Manual
Contents
1. 2 Enter the master code BYPASS 3 Press the Bypass key to delete the saved number 4 Press to end and exit Change Code Pad Tones Each code pad can have its sounder tone adjusted to your individual requirements Key Sequence Operation lt gt 1 Press 0 The code pad sounder will sound at the current set tone 2a Press 1 key to raise the tone 2b Press 2 key to lower the tone 3 Press to exit and save the selected code pad tone 0000 NX alarm system user s manual Page 17 Changing Areas In a multi area system it is possible to control more than one area from the one code pad by switching area views To change the current code pad area view follow the key sequence show below Note that once an area view is accessed the code pad will revert to the default area view after 10 seconds unless a key is pressed in which case it will only switch back 60 seconds from the last key press Key Sequence Operation 1 Press 1 to access the c b change area function 2 Enter an area number from 1 through to 8 to select the area nb to view Communicator amp Siren Test This test will only be performed if the installer has programmed this option The test conducts a communicator test if programmed and a siren test No alarms and no reports will be sent unless a communic
2. Abort Delay An option that allows a delay in reporting to the central station Authority Level The level of access an individual has when using an alarm panel Central Station Location where alarm data is sent during an alarm report Chime Feature An option that allows the code pad to sound a ding dong whenever an entry exit door is opened Codes Can be either User Codes relating to a person or Function Codes a toggle switch to turn specific functions on off Note A system may have either 99 four 4 digit codes or 66 six 6 digit codes but not a mixture of the two Duress Code An option that allows a special code to be sent to the central station that indicates the alarm system is being operated under duress Forced Arming An option that allows the system to be turned on Armed with one or more zones open A system that is ready to be force armed will flash the ready light Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a system device Group Bypass An option that allows the user to bypass multiple zones with a single operation Master Code A master PIN code that can arm amp disarm the alarm system and can add and delete user PIN codes Multi Area System A system divided into multiple areas in which a user or users control one or more areas Partial Arm A mo
3. 6 7 7 8 8 9 9 0 0 On Star Partial Hash Exit 4 Sec Delay Bypass Disable Chime Pulse Dialing NX alarm system user s manual Page 15 Viewing Telephone Numbers You may wish to check the phone numbers that have been programmed for your security system Key Sequence Operation 1a Press and 4 1 for phone 1 1b Press and 4 2 for phone 2 1c Press and 4 3 for phone 3 2 Enter the master code You are now in the view mode and the b first phone digit will be displayed Use the following table to read the code pad lights 3 Press the key repeatedly to display the saved phone number 4 Press to end and exit Zone Light Phone Digit Light Phone Digit Zone 1 1 Fire 9 Zone 2 2 Service 0 Zone 3 3 On Star Zone 4 4 Partial Hash f Zone 5 5 Exit 4 Sec Delay Zone 6 6 Bypass Disable Zone 7 7 Chime Pulse Dialing Zone 9 9 Zone 10 0 NX alarm system user s manual Page 16 Deleting Telephone Numbers You may need to delete a phone number you have previously chosen For example if you cancelled a mobile phone account Key Sequence Operation la Press and 4 1 for phone 1 1b Press and 4 2 for phone 2 1c Press and 4 3 for phone 3 b
4. memory The last alarm activation can be reviewed via the function listed below ie You can see which area has activated the alarm Key Sequence Operation The alarm memory feature will flash the zone s that created alarms and will light steady the zones that were bypassed during the last alarm Reset Latched Alarms Reset Latched Alarms function resets smoke detectors zone troubles and zone tampers alarms Note If the code pad begins beeping the reset did not execute properly Enter your code to silence the code pad Wait a few minutes and repeat the reset function to attempt another reset If the code pad still beeps after repeated attempts please contact your security installer Key Sequence Operation 1 Enter you code to silence the code pad sounder 2 Press 7 to activate the reset function NX alarm system user s manual Page 12 Setting System Date Key Sequence Operation Example shows setting date as Tuesday July 5th 2001 e 1 Press 9 6 keys 00020 erea 3 Enter the day of the week 1 Sunday 7 Saturday 4 Enter the month code BD Must be two 2 digits Eg 0 7 for July 5 Enter the day code Must be QC two 2 digits Eg 0 5 for the 5 day QC B 6 Enter the last two 2 digits of the year code Eg 0 1 for
5. to be reset Instructions are on page 15 Note This fault is global in nature and will affect all areas of a multi area system Exit To exit the Service Light mode press the key NX alarm system user s manual Page 19 Emergency Evacuation Plans An emergency evacuation plan should be established for an actual fire alarm condition For example the following steps are recommended by the US National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building Draw up a floor plan of your home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room One will be the normal exit from the building The other may be a window that opens easily An escape ladder may have to be located near the window if there is a long drop to the ground below Set a meeting place outdoors for a headcount of the building occupants and practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the fire department from a neighbour s phone Note After the insta
6. your Security Installation Company if a trouble condition exists NX alarm system user s manual Page 4 Fully Arming the System On mode On is used when the user is away from the premise and wants the interior protected Listed below are the steps to arm in the On mode 1 Close all protected doors and windows Ready light will light when all protected zones and sensors are secure Note If any zones are bypassed a sensor in that zone can be violated without affecting the ready light The security system will not arm if the ready light is not on If the power light is off you have no AC power Restore power if possible If not contact your security installation company 2 Enter your 4 digit user code to arm the system The armed and exit lights will illuminate You may now leave the building via the designated exit path Note The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire Key Sequence Operation Example shows a user code of 1234 being used to set the system to the On mode Quick Arm is used when the person arming the alarm system does not have a user code is leaving the premises and wants the interior protected Listed below are the steps to arm in the Quick Arm mode 1 Close all protected doors and windows Ready light will light when al
7. NetworX NetworX Series NX 4 8 Code Pad User Manual Australian Version pawiwes6od s w zs s ino moy 1no puy o Auedwoo uongll 1su 4no UMA YOaYD tu ls s ANOA 104 lqel eAe eq jou Aew 10 Aew 9 oqe paqiiosap senjea ay jo aWOS 310N suoljouny snoueA SAA NOLLVALLOV AON3SH3W3 uuoJed SA3X NOILONnd S uonipuoo JAAS 10 ysejj sey jjnej euoz 10 ysel MOJS Ssed q ajeoipui o pe ls uo 818 S1H9I13NOZ avi GI INOZ LNO TINd wegs s ail 1no YM uonipuoo jqno e SIEIIPUI 0 seusejj uueje aiy SA3M AHLN3 9jeoipul 0 UO s 4457 Suis pe e ep 9q seuoz pessed q gp ga uou iy epow ened Pee Way N NO x y u peuue si uu s s ay N U8UM uo S 14617 1VILHVd l uue e snoad e ejeorpur oj Seuse 4 peuuesip u9uM JO pawe uauM uo s 44517 NO WIE 8010 uonipuoo u lleq uiejs s Ino YIM 0 Apeas ji s yse wie MOJ e9IpDu o seuselj uonipuoo jqno e ejeorput O Apea si uiejs s eui jueseid st samod oy O UO s 146 39IAH3S uaym uo S 446 AdW3H UYM uo S 145 H3MOd Table Of Contents Code Pad Diagram a Inside Front s Glossaryor perrieri eate erm epi ie rtg 2 e Understanding the Code Pad lights ee 3 Code Pad TONES seis eene RR ee eh ees 4 Fully arming the system On mode a 5 e Fully arming the system Quick Arm mode eee 5 Partia
8. al Page 8 Deleting a User Code You may be required to delete a user code for example when a member of the household leaves home or the home is purchased from another family Key Sequence Operation e 1 Press and 5 keys 2 Enter an existing master code lt p 4 Press the Chime key four 4 times to delete the user code 5 Repeat steps 3 and 4 for additional user codes to be deleted 6 Press when completed Walk Test Walk test is used to test zone functionality and should be performed regularly When in walk test mode the code pad transmits the chime sound each time a zone is activated and will light the activated zone number on the code pad for the duration of the walk test period You must exit the walk test mode when you have completed testing or are satisfied the zones function correctly Note the alarm system will not report to the control room during the walk test Key Sequence Operation 3 Enter the user code to be deleted e g user code three 03 ii Enter Chime 2 Enter a master code The System is now in walk test mode 3 Walk past each motion sensor D O ED and return to the code pad to check each zone light to validate the sensors are working correctly 4 Enter a master code to exit walk test If no master code is enter walk test mode will automa
9. ator test is performed in which case a test signal will be sent The communicator and system sirens should be tested regularly Contact your security installation company to find out if this test is available Key Sequence Operation 1 Press 4 4 to initiate the ooo Note Sirens will sound during this test 2 Enter a user code to end the test NX alarm system user s manual Page 18 Service Light The service light will be lit if the security system requires service If the service light is lit press the key followed by the 2 key to determine the service condition One or more zone lights will illuminate indicating what service s is required Call your local security installation company immediately for these problems Below is a listing of what each light means in a service condition Key Sequence Operation ED 1 Press 2 and use the table below to identify the service condition Light nf ed Condition 1 System Fault Press the 1 key The zone light s that illuminates corresponds to the System fault s below 1 Over Current Fault 5 Expander Low Battery 2 Siren Trouble 6 Expander Box Tamper 3 BoxTamper 7 Expander Trouble 4 Expander Power 8 Reserved Note Fault
10. de used to arm the perimeter and unused areas of an occupied premises Perimeter The outer edge of the protected area typically the windows and doors fitted with alarm sensors Quick Arm An option that allows you to turn on arm the security system by pressing either the On or Partial key on the code pad control for arming only as programmed by the security installation company Universal Arming Uni Arm When enabled your alarm system can automatically determine whether to arm in the Full mode or in the pre set Partial mode by detecting if you exit your premises or stay inside after arming your system Note This feature can be used in conjunction with Quick Arm User Code A four 4 or six 6 digit entry used to arm or disarm the alarm system NX alarm system user s manual Page 2 Understanding the Code Pad Lights Armed Light The Armed light is lit when the alarm system is armed The Armed light is off when it is disarmed The Armed light will flash when there has been an alarm during the previous arm cycle Bypass Light The Bypass light is li when any zone in this code pad s area is bypassed The zone s that is bypassed will also be illuminated If the Bypass light is off no zones are bypassed Chime Light The Chime light is li when the chime feature is on the light is off otherwise Exit Light The Exit light is lit during the exit delay Th
11. e Exit light will flash during the last 10 seconds of the exit delay as a warning that the time is running out The user may want to restart the exit delay if the Exit light is flashing in order to prevent an alarm The user may then press the Exit key to restart the exit delay before the delay expires Fire Light A steady Fire light means a fire zone has been faulted A rapidly flashing Fire light means that a fire zone is in a trouble condition On Light The On light is lit when the system is armed The On light is off when it is disarmed Partial Light The Partial light is lit when the system is armed in the Partial mode All non bypassed zones will be delayed and follow the partial delay time When armed in Partial mode the Arm On and Bypass lights will also be lit Power Light The Power light is lit if the primary power is on The Power light will flash if the system detects a low battery condition Ready Light The Ready light is lit when the system is ready to arm and flashes if ready to force arm The Ready light is off when the system is not ready to arm because of a zone s being faulted Zone Light The zone lights are off when everything is normal A zone light will be lit if the zone has been bypassed If a zone light is flashing that zone is in alarm or has been faulted If a zone light is flashing rapidly it means that the zone is in a trouble condition Trouble conditi
12. gt 2001 7 Press to exit Your date is now set NX alarm system user s manual Page 13 Setting System Time Key Sequence Operation 2 Enter the master code Gp 3 Enter the hour code Must be two 2 digits Eg 0 9 for oo m 4 Enter the minutes code Must lt p be two 2 digits Eg 3 0 for 30 minutes 5 Press to exit Your time is now set 1 Press and 9 7 keys NX alarm system user s manual Page 14 Program Phone Numbers You may have a requirement where in the instance of an alarm activation you want the panel to dial a particular phone number Eg Your mobile phone There are three 3 phone numbers that can be programmed or changed Contact your security installation company to ask if the pager or siren tone formats are selected To program a new phone number you must do the following Key Sequence Operation la Press and 4 1 for phone 1 1b Press and 4 2 for phone 2 1c Press and 4 3 for phone 3 2 Enter the master code b lt gt 4 Enter the phone number not exceeding twenty 20 digits Use the table below to determine the key values 5 Press to end and exit Key Phone Digit 1 1 2 2 3 3 4 4 5 5 6
13. l protected zones and sensors are secure Note If any zones are bypassed a sensor in that zone can be violated without affecting the ready light The security system will not arm if the ready light is not on If the power light is off you have no AC power Restore power if possible If not contact your security installation company 2 Press the On key to arm the system The armed and exit lights will illuminate You may now leave the building via the designated exit path Note The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire Key Sequence Operation Example shows On key being used to set the system to the Quick Arm mode NX alarm system user s manual Page 5 Partially Arming the system Partial or Home mode Home mode allows you to temporarily exclude some rooms from security arming For example you may wish to exclude bedrooms at night when they are in use Home mode is also used for protecting exterior doors and windows the home perimeter when the user is inside Partial is used when the user is inside the premise and wants protection around the perimeter Listed below are the steps to arm in the Partial mode 1 Close all protected doors and windows Ready light will light when all protected zones and sensors are secure Note If any zones are bypassed a sensor in that zone can be viola
14. ll be bypassed Now you can arm your system in either the On or Partial mode Once armed pressing the Bypass key again will toggle the bypassed zones on and off Key Sequence Operation BYPASS 1 Press the Bypass key 2 Optional Enter a user code DB The Bypass light flashes 3 Press the 0 0 keys The group lt p gt lt gt bypass zone lights will turn on when bypassed BYPASS 4 Press the Bypass key again NX alarm system user s manual Page 7 Changing amp Adding User Codes On occasion you may need to change your arm disarm codes either as a security measure or for your own convenience User codes are 4 digits long and must be unique The master code must be used to change and add user codes The default master code is user code one 01 with a code of 1234 Any user code can be assigned as a master code See section User Code Authorisation Note the system must be disarmed before user codes can be changed or added Key Sequence Operation 1 Press and 5 b lt gt 2 Enter an existing master code lt gt Ep 3 Enter the user code to add or change c O 4 Enter the new four digit user code 5 Repeat steps 3 and 4 for additional user codes 6 Press 4 when completed NX alarm system user s manu
15. llation of your security system has been completed notify your local fire and police departments to give them your name and address for their records Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms KITCHEN BEDROOM eges DINING BEDROOM BEDROOM LIVING ROOM D ROOM FIRST FLOOR SECOND FLOOR IL UL Uri FRONT J m BEDROOM NX alarm system user s manual Page 20 Copyright and Warranty 2003 GE Interlogix All rights reserved NetworX is a trademark of the GE Interlogix companies Printed in the United States of America GE Interlogix These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during operation and maintenance If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser s purpose the matter should be referred to security installation company or place of purchase This document contains proprietary information of GE Interlogix and is furnished to its distributor and their customers solely to assist that customer in the operation and maintenance of the equipment described This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without prior written approval of GE Interlogix Australia Please refer to your security installation company for current warra
16. lly arming the system Partial mode sees 6 Disarming from the On or Partial mode 6 Bypassing Individual Zones a 7 Group Bypass a namen ae n asua aaa sssi 7 e Changing amp adding user codes a 8 Deleting a User Code u u u qS ini 9 lELSIc 9 e User Code Authorisation cc uu awasqa nennen 10 e Setting the Door Chime a 10 Exit mode extend exit timer U u u uuu 11 e Code Pad Emergency Keys nennen 11 Viewing Alarm Memory eene nente nnt tite inea nennen 12 e Reset Latched Alarms cerent nennen uuu 12 e Setting System Date oo eee eee u u 13 e Setting System Time ee ani en eee n Herren 14 Program Phone Numbers a 15 Viewing Telephone Numbers nennen 16 Deleting Telephone Numbers a 17 e Changing Code Pad Tone sese 17 s Changing Areas coerente e EORR IU a wasa 18 e Communicator amp Siren Test 18 Service Light rne tree DR rete 19 Warranty u a niasin ANE EE E a r e 21 Zone Descriptiors eee ete Re exi Ase Back Page NX alarm system user s manual Page 1 Glossary of Terms
17. nty information When installed as directed this product conforms to the standards set by Standards Australia on behalf of N4131 the Australian Communications Authority ACA NX USERS MANUAL NXAUSUD03 REV D 29 09 2003 NX alarm system user s manual Page 21 uxa Anuga Zone Descriptions O ON o Q FW N a Security Installation Company
18. ons are Hardwire Zone Tamper Wireless Zone Tamper Sensor Low Battery and Sensor Loss of Supervision A combination of Alarm Fault and Tamper Trouble will produce a rapid flashing light for a short period of time followed by a slow flashing light NX alarm system user s manual Page 3 Code Pad Tones Beeps for all key presses sounds a continuous tone during the entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a fire zone has a trouble condition Beeps 3 times for trying to arm with the Ready light off if Force Arming has not been selected Beeps for 1 second or emits a ding dong sound for the Chime feature Beeps during an exit delay beeps rapidly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s is bypassed Pulses when the armed status changes and a low battery is detected Pulses when the armed status changes and a tamper condition is detected Beeps to indicate telephone line cut if selected Pulses when one or more of the following conditions are detected zone or box tamper low battery AC power fail or expander trouble Entering a valid code will silence the code pad sounder when it is pulsing Please contact
19. s 1 amp 2 are global in nature and will affect all areas of a multi area system Press the key to return to the 1 of 8 service lights 2 Zone Tamper Press the 2 key and the zone light s will illuminate showing the zone s in tampered Press the key to return to the 1 of 8 service lights 3 Zone Low Battery Press the 3 key The zone light s will illuminate showing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service lights 4 Zone Loss Of Supervision Press the 4 key and the zone light s will illuminate showing which zone s has loss of supervision This only applies to wireless zones Press key to return to the 1 of 8 service lights 5 Zone Trouble Press the 5 key and the zone light s will illuminate showing which zone s has a trouble condition Press the key to return to the 1 of 8 service lights 6 Telephone Line Trouble Line Cut There is telephone line trouble or the telephone line has been cut The service light will remain lit until the telephone trouble clears and a user code is entered Note This fault is global in nature and will affect all areas of a multi area system 7 Failure To Communicate There is a failure to communicate between your system and the central station Note This fault is global in nature and will affect all areas of a multi area system 8 Loss Of System Time There has been a loss of power and your system clock needs
20. ted without affecting the ready light The security system will not arm if the ready light is not on If the power light is off you have no AC power Restore power if possible If not contact your security installation company 2 Press the Partial key The bypass light will illuminate if any zone s is bypassed The light s corresponding to the bypassed zone s will illuminate alerting the user that a zone s may be unprotected and can be faulted without an alarm Key Sequence Operation Press the Partial key to partially PARTIAL arm your premises Disarming From the On or Partial mode When you enter the protected area through one of the designated Entry Exit doors the code pad control will sound a solid continuous tone for the duration of the entry delay time or until you enter a valid code After entering a valid code the red armed light will go off and the tone will stop The security system is now Disarmed If a valid code is not entered before the end of the entry delay an alarm will occur Note If the red armed light is flashing during the entry delay the alarm system has been activated in your absence Leave the building immediately and call your alarm company and or the police from a safe location Key Sequence Operation Enter your user code to disarm the p system from the On or Partial mode NX alarm system
21. tem user s manual Page 10 Exit mode extend exit timer Exit mode is used when you have already armed your Security System but need to extend your exit time Pressing the exit button will re start your exit time but you may only press Exit button twice The code pad will beep faster in the last ten 10 seconds as a warning Key Sequence Operation Press the Exit key to extend the exit time Code Pad Emergency Keys Three 3 emergency features are available to be programmed into your code pad to provide support in the areas of personal safety Medical Police duress and Fire alarm You must hold these keys for two 2 seconds to activate these functions You should press these keys only in an emergency situation that requires response by emergency personnel Check with your security installation company to find out if your system is programmed for these activation keys Key Sequence Operation Press this key and hold for two 2 seconds to activate the fire alarm Press this key and hold for two 2 seconds to activate the medical auxiliary alarm Press this key and hold for two 2 seconds to activate the police duress panic hold up alarm NX alarm system user s manual Page 11 Viewing Alarm Memory Whenever an alarm activation occurs on your system all zones that were in alarm during that activation will be held in
22. tically exit in 15 minutes NX alarm system user s manual Page 9 User Code Authorisation Any User Code can be assigned the master code status to allow the user to change or add other codes and provide access to other system functions Key Sequence Operation Example shows user two 02 code change gt 1 Press 6 keys lt gt 2 Enter an existing master code lt p 3 Enter the user code to have changed to a master code 4 Press 4 key 5 Repeat steps 3 and 4 for additional user codes 6 Enter to save changes 7 Enter when completed Setting The Door Chime Chime Mode provides only an audible warning at the premises A ding dong is sounded from the code pad when the protected area is entered for example when an infant opens the door The door chime is turned on or off by pressing the Chime key while the system is in the disarmed state If the chime is on the Chime light will be lit If the chime is off the chime light will be off Each press of the Chime key will toggle the chime feature on off Chime mode must be programmed by your security Installation Company Tell the installer if Chime mode is required for any areas Key Sequence Operation Press the Chime key to turn on or turn off the chime feature NX alarm sys
23. user s manual Page 6 Bypassing Individual Zones Bypassing is used to temporarily exclude one or more zones that would normally be protected For instance a pet may need to be left in a part of the house that is usually protected If you wish to bypass one or more zones this must be done while the system is in the disarmed state The following steps are used for bypassing zones Once you have bypassed the zone s you may arm the system via the On or Partial mode When your security system is disarmed any zones that has been temporarily isolated or bypassed will be reset and will therefore be protected when the system is armed again To manually un bypass zones perform the bypassing procedure on a zone that is already bypassed The corresponding light for that zone will go off when un bypassed Key Sequence Operation This example shows a user bypassing zones 4 and 5 1 Press the Bypass key 2 Optional Enter a user code Ee The bypass light flashes 3 Enter the 2 digit zone number s lt p you wish to bypass E g Press the 0 and the 4 keys for zone 4 0 and the 5 keys for zone 5 The lt p corresponding light for that zone will turn on when bypassed 4 Press the Bypass key BYPASS BYPASS Group Bypass By pressing the Bypass key followed by the 0 0 keys then the Bypass key again all zones that are designated as group bypass zones wi
Download Pdf Manuals