Home
ERT Wireless DYNALINK user manual
Contents
1. ERT WIRELESS DYNA LINK USER MANUAL TABLE OF CONTENTS SAFE OPERATION GUIDE vou al Padang san ts 2 CHAPTER 1 FEATURES AND SPECIFICATION 0 cccccccccscesceseessceseceseeesecnseeasenseenseenes 3 VSFEAUTES sdevck odes O 3 2 Main technical data ooooonnoconnonocnoonnnooncnoonnnncnnnnnonnnnonnno Ge eeaeeeeeaeeeaeeeeaaes wid SPS peccato ninisi thcee tbs eds qaubalh aabetdoaduebwsonredde ton odode ns 4005 sods acdaladhesdsnabanls A EATE ven gesssuts 3 A Appearance MAA RO 4 S POWer SUPPLY ride 4 CHAPTER 2 DISPLAY AND KEY oeoscsccisvicsdecceses cc cvcsvovsessuset iecevactede aevsatagsvteuteseuslacstdunles siete 5 Teed Gis NS NON 5 Ze WEY ATCA O NN NN 5 CHAPTER3 WIRELESS INDICATOR OPERATION GUIDE oononcconoconoconoconnonononnnonnninnos 7 CHAPTER 4 DYNA LINK FUNCTION GUIDE ooooooccconcooccooncconononcnonnononcononocancnnancnconnnonnncnnnos 8 A rinie t a E OR 8 E TO 9 A A eee ee 9 4 Peal aa 9 JAceumM lAt Ohne a eee 9 6 Acc m lation Searchin a A Nae Hoes ase e eee 9 7 ACCUMULA ONC ISAT sissies pelesehled A UR A vk 9 8 Battery Voltage Check nr aia Rn EA A E Aaa 10 Unit Con Vedra de AAA AAA ART AI aida 10 CHAPTER 5 PARAMETER SETTING amp CALIBRATION cooooocccconcoccnnocnnoonnconncnnonnnconnconnconoonnnos 10 l Parameter setting arrneo inensis ia dados dl o 10 DECIDA A A eee cree 13 CHAPTER 6 SIGNAL ILLUSTRATION cccsccccsssseecsccccesssccceessecceeesecesesesceeesesceea eens 14 CHAPTER 7 TROUBLE
2. ILLUSTRATION DISPLAY ILLUSTRATION REMARK no519 Without wirelsee signal SEtUP Enter parameter setting UAdJ 2 Enter voltage calibration LoAd Calibration point Cm J Exceed high limit Tare weight can t exceed full capacity Ko J Exceed low limit Tare weight can t be negative K Waiting Err10 Weight less than Min Capacity Can t accumulate the value KErr11 J Accumumated times overflow Can t accumulate after 30times Err12 Accumulated weight overflow Can t accumulate after 99999 Err13 Error in repeat accumulation Can t accumulate one weight repeatedly Kno Current accumulation times KH Front four digit of accumulated Total weight front four digit rare four weight digit E veas Rare four digit of Total weight front four digit rare four accumulated weight digit K CLr 2 Ask if you really want to delete In case error deletion accumulated weight noCLr Give up deletion 88888 Confirm deletion Y Input value is too large When you input tare or weight value KD Input value is too small When you input tare or weight value noACCA No any accumulated content when you check accumulation oLO Overload warning Tare Net weight exceed full capacity oL1 J Overload warning Tare Net weight exceed full capacity Lb J Low battery warning Turn o
3. Press ENTER Key access unit selection Press ZERO key to select unit press MODE key again back to test mode Press MODE key 5 times display ACCU Press ENTER Key access Accumulation Status press MODE key again back to test mode Press MODE key 6 times display SACCU Press ENTER Key access Accumulation Search Status press MODE key again back to test mode Press MODE key 7 times display clEAr Press ENTER Key access Accumulation clear Status display CLr Press ENTER Key again display noCLr press MODE key again back to test mode Press MODE key 8 times display CLIBr Press ENTER Key 3 seconds access calibration Status if press ENTER key less than 3 seconds it will back to test mode Press MODE key 9 times display dFuLt Press ENTER Key and PEAK Key 3 secondsback to default setting PEAK When weight is changing gt press this key will display the maximum reading 2 Press this key again gt reading will resume changing CHAPTER 4 DYNA LINK FUNCTION GUIDE Note means the key on overlay means the key on wireless indicator 1 ON OFF TURN ON Press ON OFF 3seconds gt display as below OPERATION DISPLAY ILLUSTRATION ON OFF 8 8 8 8 8 Display twice K Ert J Display twice K1000 0 Display twice capacity KU 6 XX Display current battery voltage Ku 2 1 Display current softw
4. Standard Features 90 44 9969894 906 Rugged construction Accuracy 0 1 of capacity All fuctions and units are clearly display on the LCD with backlighting Digits are 1 inch high for easy distant viewing Two user programmable Set Point can be used for safety and warning applications or for limit weighing Long battery life on 3 standard LR6 AA size alkaline batteries All commonly used internationally recognized units are available kilograms kg short Tons t pounds 1b Newton and kilonewton kN Infrared Remote control easier to calibration with password Infrared Remote control with many fuctions ZERO TARE CLEAR PEAK ACCUMULATE HOLD Unit Change Voltage Check and Power OFF 4 local mechanical keys ON OFF ZERO PEAK and Unit Change low battery warning RF wireless palm indicator 2 Main technical data Display 25mm 1 Sdigits LCD Power on zero range 20 ES Manual Zero Range 4 ES Tare Range 20 ES Stable Time lt 10 seconds Overload Indication 100 ES 9e Max Safety Load 125 ES Ultimate Load 400 ES Battery Life gt 40 hours Battery Type LR6 AA size alkaline batteries 1 5V x 3 Operating Temp 10 C 40 Operating Humidity lt 85 RH under 20 C Wireless Distance Min 80m default 200m optional Wireless Frequency 2 4GHz default 433MHz 86
5. 0MHz optional USER MANUAL 3 ERT1 001 018 SSE 3 Specification MODEL Max capacity Min weigh Division Total display kg lb kg Ib kg Ib counts n ERT 01 1000 2200 10 20 0 5 1 n 2000 ERT 02 2000 4400 20 40 1 2 n 2000 ERT 03 3000 6600 20 40 1 2 n 3000 ERT 05 5000 11000 40 80 2 4 n 2500 ERT 10 10000 22000 100 200 5 10 n 2000 ERT 15 15000 33000 100 200 5 10 n 3000 ERT 20 20000 44000 200 400 10 20 n 2000 ERT 30 30000 66000 200 400 10 20 n 3000 ERT 50 50000 110000 400 800 20 40 n 2500 ERT 100 100000 220000 1000 2000 50 100 n 2000 ERT 200 200000 440000 20000 4000 100 200 n 2000 USER MANUAL 4 ERT1 001 018 SSE 4 Appearance illustration CAPACITY A mm B mm C mm D mm mm H mm MATERIAL 1000kg 245 112 37 190 43 335 Aluminium 2000kg 245 116 37 190 43 335 Aluminium 3000kg 260 123 37 195 51 365 Aluminium 5000kg 285 123 57 210 58 405 Aluminium 10000kg 320 120 57 230 92 535 Steel 15000kg 375 128 74 260 127 660 Steel 20000kg 375 128 74 260 127 660 Steel 30000kg 420 138 82 280 146 740 Steel 50000kg 465 150 104 305 184 930 Steel 100000kg 570 190 132 360 229 1230 Steel 200000kg 725 265 183 440 280 1380 Steel 5 Power supply Battery LR6 AA size alkaline batteries 1 5V x 3 Current the Dyna link load guage average current is ab
6. AMETER SETTING CALIBRATION You can use wireless indicator to operate parameter setting and cabibration 1 Key function KE FUNCTION TARE Move digits ZERO Set value up MODE Storage and exit ENTER Confirm 2 PARAMETER SETTING OPERATION DISPLAY ILLUSTRATION Press MODE two times KSETUP Confirm enter parameter setting program Press ENTER KFS 06 New Dyna link the screen display FS 06 gt if dyna link calibrated gt the screen display capacity USER MANUAL 10 ERT1 001 018 SSE OPERATION DISPLAY ILLUSTRATION Press ZERO to choose FS 02 Choose capacity gt the screen display 02 03 05 06 10 15 20 30 50 60 75 circularly gt take cap 2000kg as example choose FS 02 Press ENTER to confirm KId 02 New Dyna link gt the screen display Id 02 if dyna link calibrated gt the screen display calibrated division Press ZERO to choose KId 01 Choose division gt the screen 01 02 05 10 20 circularly 2000kg division is 1kg so choose Id 01 display Dyna link Pt 0 New Dyna link gt the screen display Pt 0 if Dyna link calibrated the screen display calibrated decimal position Press ZERO to choose Pt 0 Choose decimal position the screen display 0 1 2 3 circularly O xxxxx 1 xxxx x 2 XXX XX 3 xx xxx gt Cap 2000kg Dyna link choose Pt 0 Press ENTER to conf
7. N SEARCH OPERATION DISPLAY ILLUSTRATION Press MODE key 6 times KNo Current accumulation time Then Press ENTER Key Kxxx Current weight reading H Front four digits of total value KL 3 Rear four digits of total value Press MODE key again Return Press TARE and ZERO can check different times weight and accumulation USER MANUAL 9 ERT1 001 018 SSE 7 ACCUMULATION CLEAR OPERATION DISPLAY ILLUSTRATION Press MODE key 7times K CLr Ask if you want to clear or not ThenPress ENTER Key KnoCLr Press MODE key Cancel clear 8 8 8 8 8 Press ENTER key Confirm clear 8 BATTERY VOLTAGE OPERATION DISPLAY ILLUSTRATION Press MODE key 3 times KU Display current battery display dC press ENTER key voltage Press MODE key again Return Note Battery voltage normally between KU 3 50 to KU 4 70 if below KU 3 10 display will flash gt Battery should be changed 9 UNIT CONVERT OPERATION DISPLAY ILLUSTRATION Press MODE key select Unlt KUn 00 press ENTER key Unit press ENTER key will be changed circulate Press MODE key again Return 10 Return to normal testing status OPERATI DISPLAY ILLUSTRATION Press MODE keyselect ESC ENTER key Return to normal testing status press CHAPTER 5 PAR
8. SHOOTING GUIDE ooooooocccoccnononcnonononncnonccnoncconccnoncononcn cono conononcncncaninnos 15 USER MANUAL 1 ERT1 001 018 SSE SAFE OPERATION GUIDE 1 Do not overload this Dyna link load guage 2 Do not perform overhead weighing Stay clear when Dyna link load guage is in operation 3 Do not perform weighing under strong wind condition which may cause incorrect reading 4 Do not perform weighing under enviorment of temperature rapid changes in which may Cause incorrect reading 5 Do not attempt to open this Dyna link load guage no user serviceable parts inside 6 Do not remove wire rope stopper from hook For safety reasons always apply it 7 Remove all loads from shackle or hook when not in used 8 Before weighing check and make sure that all hanging load receiving elements devices are in good condition 9 Check hook shackle safety pins and latches periodically Contact_your dealer for parts replacement in case defect deform or wearing is found 10 Always lift loads vertically USER MANUAL 2 ERTL 001 018 SSE CHAPTER 1 FEATURES AND SPECIFICATION Profile ERT wireless Dyna link load guage is an extremely well built instrument for industry use as a standard wireless tool offer universal applications Whether used as conventional crane weigher or to measure force ERT wireless Dyna link load guage is microprocessor controlled for precision accuracy calibration is easier with wireless indicator 1
9. are version J Waiting stable K O STB light on you can operate now USER MANUAL 8 ERT1 001 018 SSE TURN OFF 1 Manual Power OFF Press ON OFF Key 3Seconds 2 Remote Power OFF Press MODE Key select OFF press ENTER Key 3Seconds Choose turn off method when parameter setting the 3 Auto Power OFF Scale will display K after no operation at 15minutes to save power and it will turn off automatically after 60minutes 2 ZERO OPERATION DISPLAY When Dynalink turn on generally it Press ZERO K 0 displays K 0 if display small digits when no 2 Press ZERO load press this key 3 TARE OPERATION DISPLAY After turnon hanging tare weight such as sling cable at first press this key 1 Press TARE K 02 TARE light on then the scale will display net weight of the goods 4 PEAK HOLD OPERATI ILLUSTRATION Press PEAK or PEAK Display Maximum value Press PEAK or PEAK again reading will resume changing 5 ACCUMULATION OPERATION DISPLAY ILLUSTRATION Press MODE keyS5times KNo Current accumulation time Then Press ENTER Key H Front four digits of total value KL Rear four digits of total value After display above contents twice the DYNA LINK will return automatically 6 ACCUMULATIO
10. ely sequence change kg Po Tb klb gt N k N gt kg d PEAK When weight is changing gt press this key will display the maximum reading 2 Press this key again gt reading will resume changing CHAPTER3 WIRELESS INDICATOR OPERATION GUIDE O ZERO a In testing status there are small digits on screen press this key to obtain the zero reading b In Parameter Setting status gt it Used as scrolling up ITARE a Hang sling or container on the hook when the reading stable press this key the digits display 0 and N indicator Flash b Put the goods into container the DYNA LINK will display goods net weight c If move goods and container the DYNA LINK will display minus value of tare weight d In Parameter Setting status gt it Used as digits movement MODE Used as function select or can be combined with other Keys ENTER USER MANUAL 7 ERT1 001 018 SSE Used as function select gt normally combined with MODE Key Press MODE key once display OFF Press ENTER Key to realize remote power OFF Press MODE key twice display SETUP Press ENTER Key access Parameter Setting status Setting finish press MODE key again storage data and back totest mode Press MODE key 3 times display dC Press ENTER Key to inquire battery voltage press MODE key again back to test mode Press MODE key 4 times display Unit
11. en display OFF 1 if confirm dyna link calibrated gt the screen display calibrated value Press ZERO to OFF 2 Choose turn off method 0 2 total 3 choose options 0 turn off by hand 1 if no operation the screen display KC after 15minutes to save power 2 if no operation the screen display K after 15minutes and turn off automatically after 60minutes Generally choose OFF 2 when ex stock Press ENTER to confirm K SP1 Set point 1 Press ENTER toconfirm K1 OFF New dyna link gt the screen display 1 OFF if dyna link calibrated gt the screen display calibrated value Press ZERO to choose K1 LO Choose Set point 1 mode l OFF means setpoint 1 no function 1 LO is Set point 1 lower 1 HI is Set point 1 High Press ENTER confirm 02000 New dyna link gt the screen display 02000 if dyna link calibrated the screen display calibrated Press ZERO to set 020003 Set 1 LO or 1 HI Value value Press TARE to move digit Press ENTER to confirm K SP2 Set point 2 Press ENTER toconfirm 2 OFF New dyna link gt the screen display 2 OFF if dyna link calibrated gt the screen display calibrated value Press ZERO to choose K2 LO Choose Set point 2 mode 2 OFF means set point 2 nofunction 2 LO is Set point 1 low value 2 HI is Set point 2 High value Press TARE to confirm 02000 Ne
12. ff automatically one minute later U The voltage of current battery K End 3 End when parameter setting or calibration K OFF 3 Turn off KUnstb Input value before STB light on NOTE If you turn off the DYNA LINK immediately turn on it sometime it will disply K oL1 3 though it without any hanging Just turn off it waiting few minutes USER MANUAL 14 ERT1 001 018 SSE CHAPTER 7 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOUTION No display Defective battery Replace Defective button Requires authorized service Power button not Press ON OFF key firmly properly depressed in three seconds Digits flash Low battery Recharge the battery Display doesn t respond to Faulty loadcell or PCB Requires authorized service load changes Out of calibration Re calibration Display experiences excessive DYNA LINK do not stabilize After turning on heating 3 5 Zero drift between weighment after turning on minutes Displayed weight shows large DYNA LINK not Zeroed Depress ZERO before error before applying weight applying weight Requires recalibration See calibration Kg lb wrong selecion See operation Wireless distance shortened Wireless indicator s battery is low Replace battery USER MANUAL 15 ERT1 001 018 SSE
13. irm KAb 24 Display zero range A zero range by hand B zero range automatically 0 5 total 6 options 0 0 F S 1 2 FS 2 4 FS 3 10 FS 4 20 ES 5 50 FS Generally Don t change this Press ENTER to confirm KCd 11 New Dyna link gt the screen display Cd 11 if Dyna link calibrated gt the screen display calibrated value Press ZERO to confirm KCd 11 C zero tracking range 0 5 total 6 options 0 0d 1 0 5d 2 1d 3 1 5d 4 2d 5 2 5d speed 0 2 total O slow l average 2 fast before calibration set d display 3 options Cd 00 after calibration set Cd 11 again generally choose Cd 11 when ex stock Press ENTER to confirm LL 2 New Dyna link gt the screen display LL 2 if dyna link calibrated gt the screen display calibrated value Press ZERO to choose LL 2 LL filter parameter gt 0 3 total 6 options gt from smallest tobiggest gt before calibration set LL 0 after calibration set LL 2 again generally choose LL 2 when ex stock USER MANUAL 11 ERT1 001 018 SSE Press ENTER to KUn 0 New dyna link gt the screen display confirm Un 0 if dyna link calibrated gt the screen display calibrated unit Press ZERO to Un 0 Choose unit gt Un 0 kg Un 1 lb Un 2 N choose Un 3 KN Un 4 ton Generally choose Un 0 when ex stock Press ENTER to KOFF 1 New dyna link gt thescre
14. out DC 25mA 3pcs new batteries can be used for about SOhours wireless indicator average current is about DC 20mA 4pcs new batteries can be used for about 80hours Low battery warning When the digits flashes it means the battery needs to be replaced The Dyna link load guage or wireless indicator will power off automatically after half hours operation USER MANUAL 5 ERT1 001 018 SSE CHAPTER2 DISPLAY amp KEY 1 LCD DISPLAY a 25mm 1 Sdigits LCD with all fuctions and units b Wireless signal it Appear means signal stable it disppear while signal miss it flash means signal weak c ll Battery Voltage T Full UM Lov Empty d PEAK Current value is Peak Hold value maxmium value e MEM Appear one time when Parameter or calibration value storage long time appearance means current value is Accumulation data f STB Stable Status g kN kilonewton N Newton Tare status N will flash h t ton i lb pound j kg kilogram 2 Key Area a ON OFF Power ON amp Power OFF 1 Press ON OFF Key 3 Second the Dyna link load guage turn ON 2 In ON status Press ON OFF Key 1 Second the Dyna link load guage turn OFF USER MANUAL 6 ERT1 001 018 SSE b ZERO When DYNA LINK load guage switch on with no load on the hook but there are small digits on screen press this key to obtain the zero reading c UNIT Press UNIT key the unit on LCD will circl
15. w dyna link gt the screen display 02000 if dyna link calibrated gt the screen display calibrated value USER MANUAL 12 ERT1 001 018 SSE Press ZERO value Press TARE to to set 02000 Set 2 LO or 2 HI Value move digit Press ENTER to confirm K g acceleration of gravity Press ENTER to 9 7940 New dyna link gt the screen display 9 7930 if confirm dyna link calibrated gt the screen display calibrated value Press MODE K End 2 Confirm above parameter setting gt Exit parameter setting program 3 calibration OPERATION DISPLAY ILLUSTRATION K 0 Take Cap 2000kg Dyna linkas example gt pay attention that the screen display K oJ after hanging tare weight you can hang tare weight at first then turn on Press MODE key 8 KLoAd No load gt the screen display 0 and wait until STB times display CLIBr display Press ENTER Key 3 seconds access calibration Status Hanging standard weight Waiting until STB signal on screen 2000kg Press ENTER Key 02000 Display capacity you choose when parameter setting gt and first digit flash gt Do wait until STB signal on screen Press MODE key to J Confirm storage K oL End J 2000 02 Press TARE key to 20007 Calibration end Shift digit USER MANUAL 13 ERT1 001 018 SSE CHAPTER 6 DISPLAY
Download Pdf Manuals
Related Search
Related Contents
Télécharger Zie Handleiding H40-70FT - Hyster Company BladeRunner Ether-Cut™ User Manual CandCNC Fiche de Sécurité SMC EZ Connect 10/100 Network Adapter logo della ditta - Ministero della Difesa SICOR S.p.A. - LIFT COMPONENTS Pluviol - Ceresita Uruguay user manual. - Battery Traders Copyright © All rights reserved.