Home
DANGER DANGER - Hearth & Home Technologies
Contents
1. 381 mm wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2 51 mm Measure 183 4 476 mm from the end of the pipe Place the next spring 5 127 mm from the previously installed spring Place the next spring 6 152 mm from the last spring Finally place the last spring 12 305 mm from the last spring installed Figure 19 Step 5 Install the 4 102 mm flex vent pipe to the appliance col lar as described on Page 13 Secure the end with the first spring 183 4 476 mm from the flex pipe end to the unit Step 6 Slide the 7 178 mm flex vent pipe over the 4 flex vent pipe and secure the 7 collar as described on Page 13 Step 7 Bend the flex pipe horizontal so the bottom of the horizon tal pipe measure 181 2 470 mm from the top of the unit immediately after the 90 formation Figure 20 Be sure to follow the 1 2 13 mm rise in a 12 305 mm horizontal run rule Step 8 Install the 4 flex then 7 flex to the termination 18 VENTING INSTALLATION 4 Flex Vent Pipe 12 es 305 mm A Spacer 6 Spring 152 mm 5 127 mm f Figure 19 pean Install Spacer Springs FP1474 Figure 20 Bend Flex Vent at 90 so Horizontal Portion is 181 2 470 mm Off Top of Unit Includes collar height 12 straight section and bend radius BELOW GRADE INSTALLATION When it is not possible to meet the required vent terminal clea
2. 1 Press down the battery door tabs and pull out to remove battery door 2 Install the batteries as indicated on Command Center 3 Close battery door by snapping in place 4 5 TSFSC TSTSC TSMSC RTSC RMSC Three Flame Height Settings X X X X X Low battery Indication for Transmitter X X X X X Child Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Thermostat Auto Flame amp Blower Modulation X xX x f x ee x za x When the four 4 batteries are installed the system will operate without power The batteries should be replaced when the LED indicates low battery or at least once a year 20306741 35 BLDV7 Series Gas Fireplace SYSTEM CONFIGURATION SETUP All System configuration setup is done on the Command Center NOTE When using On Off wall switch the switch must be in the ON position to perform all configuration set ups at the command center COLD CLIMATE OPTION Choose the Mode That Best Suits Your Needs The Signature Command System is designed to operate in either Standing Pilot or Intermittent Pilot mode The Standing Pilot Mode is best for colder climates when the pilot must remain on continuously to prevent condensation and ensure reliable operation e The Intermittent Pilot Mode is ideal for maximum effi ciency igniting the pilot only when needed to start your fireplace l
3. box Then proceed to remove the glass frame by following the steps below 1 Remove access panel by lifting up and out 2 Release two clamps 500 model has three clamps on bottom of fireplace Figure 32 3 Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace 4 Set glass frame aside Each clamp has a quick spring force When reinstalling clamps keep fingers clear z Q a gt lt q O E Q Safety Screen Figure 32 Remove Glass Frame 24 FIREPLACE INSTALLATION HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed N 20306741 FIREPLACE INSTALLATION BLDV7 Series Gas Fireplace EYEBROW CANOPY INSTALLATION 1 Remove glass frame 2 Hold eyebrow canopy with groove facing up and tabs for screws facing down Figure 33 3 Install by placing eyebrow under bottom lip of facing Hook bottom lip of facing into groove of eyebrow Pull eyebrow forward until it stops Figure 33 4 Insert self tapping screws into tabs on bottom of eye brow and into sides of facing NOTE Eyebrow canopy is optional depending upon clear ances to combustible mantels and trim Refer to Page 9 Facing Eyebrow Canopy Eyebrow Canopy
4. or 5 8 J a3 or 16 mm Rough E E rl Ul C Q 4 ieee Figure 2 i je H A Fireplace Specifications and O e H lo t 4 m a Framing Dimensions k A gt y J FEKE Gas Line Access BLDV300 BLDV400 BLDV500 A 34 876 mm 376 941 mm 41 e 1043 mm B 27 s 686 mm 29 737 mm 33 838 mm C 37 959 mm 40 1032 mm 40 1032 mm D 2714 692 mm 30 768 mm 34 870 mm E 15 e 395 mm 17 e 446 mm 17 e 446 mm F 22 567 mm 251 656 mm 25 e 656 mm G 294 745 mm 31 810 mm 31 810 mm H 306 764 mm 31 e 811 mm 35 e 913 mm l 3 76 mm 3 76 mm 3 76 mm J 1 25 mm 1 25 mm 1 25 mm K 9 243 mm 11 289 mm 11 289 mm L 176 24 mm 1 6 24 mm 1 6 24 mm M 13 346 mm 15 384 mm 17 435 mm N 7 184 mm 76 186 mm 7 186 mm O 2 57 mm 2 e 65 mm 2 e 65 mm P 7 191 mm 7 197 mm 7 197 mm Framing Dimensions Q 38 987 mm 41 1060 mm 41 1060 mm R 34 886 mm 3776 951 mm 4176 1053 mm S 15 403 mm 176 433 mm 17 e 433 mm T 56 e 1430 mm 64 1645 mm 68 1746 mm U 287 2 736 mm 32 822 mm 34 873 mm V 39 e 1011 mm 45176 1164 mm 48 1235 mm 20306741 PRE INSTALLATION INFORMATIO
5. Minimum Ae E E Figure 13 Maximum Horizontal Run with 12 Minimum Rise 16 VENTING INSTALLATION Example According to the vent graph Page 15 the maximum horizontal vent length in a system with a 71 2 2 3 m rise is 20 6 m and if a 90 elbow is required in the horizontal vent it must be reduced to 17 5 2 m In Figure 15 dimension A plus B must not be greater than 17 5 2 m The maximum number of 45 elbows permitted per in stallation is six 6 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of the horizontal run MUST be reduced by 18 457 mm This does not apply if the 45 elbows are installed on the vertical part of the vent system The maximum number of elbow degrees in a system is 270 Figure 15 Example Elbow 1 90 Elbow 2 45 Elbow 3 45 Elbow 4 90 Total angular variation 270 90 Se B NN a A B 17 Max VA 5 2m 7 6 2 3m Figure 14 FP1178 Horizontal Run Reduction eee 2 E ia 4 12 305 mm N Section Minimum ie Figure 15 Maximum Elbow Usage _ 1 2 3 4 270 FP1180 20306741 VENTING INSTALLATION VERTICAL SIDEWALL INSTALLATION TWIST LOCK PIPE Step 1 Locate vent opening on the wall It may be necessary to first position the fireplace and measure to obtain hole lo cation Depending on whether the wall i
6. be a minimum of 1 305 mm below the termination cap Figure 7 Termination Clearances ASSEMBLING VENT PIPES USA Installations The venting system must conform to local codes and or the current National Fuel Code ANSI Z223 1 NFPA 54 Only venting components manufactured or approved by Vermont Castings Group may be used in Direct Vent sys tems Canadian Installations The venting system must be installed in accordance with the current CSA B149 1 installation code FLEX VENT PIPES Secure flex vent pipe in place with a hose clamp pro vided Be sure the flex pipe overlaps at least 1 25 mm onto the collars of the fireplace and termination If the termi nation has an internal bead be sure to overlap and se cure 1 25 mm past the bead 20306741 Be sure the vent is actually crushed before proceeding Apply a tug to be sure the vent will not slip off the collars Repeat process with 7 flex vent pipe The same proce dure must be performed on the vent side Hose Clamp Figure 8 Secure Flex Pipe with Hose Clamps FP2336 13 BLDV7 Series Gas Fireplace TWIST LOCK PIPES When using twist lock pipe it is not necessary to use sealant on the joints To join twist lock pipes together simply align the beads of the male end with the grooves of the female end twisting the pipe until the flange on the female end contacts exter nal flange on the male end It is recommended that you secure t
7. 36 Vent Pipe 7TDVP36 7TDVP36 30 7TDVP48 7TDVP48 30 ee s 1 Firestop 7DV1FS 1 Attic Insulation Shield 7DV1AIS Combination Horizontal Offset Roof Support IDVCS 20306741 47 BLDV7 Series Gas Fireplace VENTING COMPONENTS HORIZONTAL VENTING Horizontal Vent Termination Kits Rear Vent Hot Touch Termination Kit w 10 to 16 7TBRHTK Adjustable Termination Pipe Firestop and Hot Touch Termination w Siding Shield Up and Out Side Wall Termination Kit w 10 to 16 7TDVSCTK Adjustable Termination Pipe 90 Elbow Firestop and Cool Touch Termination w Siding Shield Rear Vent Cool Touch Termination w Siding Shield for 7TRVCT 8 Straight out Applications and Firestop 8 pack Rear Vent Hot Touch Termination w Siding Shield for 7TRVHT 8 Straight out Applications and Firestop 8 pack Termination Guard for 7 T L Rear Vent Hot Touch 7TRVTG Terminations 97TRVT 7TSVKT Snorkel Termination 7TDVSNORK 7 T L DVRTSB Termination Screen Guard 7TBSG Up and Out Starter Kit w 40 Flex Pipe Firestop Cool 7FDVSCTK Touch Termination w Siding Shield and 2 ea Clamp U ie 5 Q o Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 16 Adjustable Termination Pipe 4 pack 7TDVPA 4 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack
8. 450 mm Example Maximum horizontal length No elbows 10 3 m 1 x 45 elbow 8 5 2 6 m 2 x 45 elbows 7 2 1 m e Aminimum of an 8 2 5 m vertical rise is required e Two sets of 45 elbow offsets may be used within the vertical sections From 0 to a maximum of 8 2 5 m of vent pipe can be used between elbows Figure 23 e 7DVCS supports offsets Figure 27 This application will require that you first determine the roof pitch and use the appropriate starter kit Refer to Venting Com ponents List The maximum angular variation allowed in the system is 270 Figure 24 e For the minimum height of the vent above the highest point of penetration through the roof refer to Page 21 Figure 28 Max Height 40 12 m Min Height 8 2 m Max 10 3 m I LI 12 305 mm Min Support Straps Every 3 914 mm Figure 23 Support Straps for Horizontal Runs 19 BLDV7 Series Gas Fireplace 1 2 3 4 270 Figure 24 Maximum Elbow Usage FP1179 VERTICAL THROUGH THE ROOF INSTALLATION NOTE For all top vent vertical through the roof installa tions install the supplied cross bar flue restrictor onto the top edge of the firebox flue adapter Figure 25 1 Locate your fireplace 2 Plumb to center of the 4 flue collar from ceiling above and mark position 3 Cut opening equal to 93 4 x 93 4 248 x 248 mm 4 Proceed to plumb for ad ditiona
9. 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 45 Elbow for Vertical Horizontal Offset 45 Elbow for Vertical Offsets 8 pack 90 Elbow for Vertical Horizontal Offset 90 Elbow for Vertical Horizontal Offset 8 pack 7TDV45 7TDV45 8 7TDV90 7TDV90 8 7DV1FS 7DV3FS TDVIAIS 7DVCS 1 Firestop 3 Firestop 1 Attic Insulation Shield Combination Horizontal Offset Roof Support Model Number 48 20306741 VENTING COMPONENTS BLDV7 Series Gas Fireplace VENT COMPONENTS FOR 4 X 6 Duravent Selkirk 4 x 6 Metal Fab Current Old Duravent Duravent or Vermont or Vermont Qty Castings Group Castings Group Selkirk Metal Fab Item Box Description Part no Part no Part no Part no 1 1 Thru roof Flexible Pipe Termination Kit with flex adapter TRFK 24 rigid pipe roof support 4 x 65 8 and termination cap 1 1 Horizontal Square Termination Cap with built in vinyl BHRTK BHRTK siding standoff heat deflector and firestop 1 1 Square Horizontal Termination Cap 46DVA HC 985 4DT HC 4DHT 1 1 Round Horizontal Termination Cap 46DVS HRCS 1 1 Sconce Termination Cap aluminum 46DVA HSC 2 1 Low Profile Vertical Termination Cap 46DVA VC 980 4DT VC 4DVT 3 6 6 Pipe Length galvanized 46DVA 06 908 4DT 06 4DV6 3 6 9 Pipe Length galvanized 46DVA 09 907 4DT 09 3 6 12 Pipe Length galvanized 46DVA 12 906 4DT 1 4D12 3 6 24 Pipe Length galvanized 46DVA 24 9
10. O da E 11 Rock WOO E S EEEE ET 39 Termination Location sccieetiettwenietion 12 Troubleshooting sssssssscesesesesesssssseessesesceeseaeee 40 Termination Clearances see 13 General stores atta a ia a 40 Assembling Vent Pipes n se E Signature Command System 41 Twist Lock Pipes a aa iea i How to Use the Vent Graph 14 di PER E RS ago petite apt S E AR ge po Vent Pipe Clearances to Combustibles 15 Signature Command System AA S ks 44 Vertical Sidewall Application 16 DO ec nae ead tine ie tate A 46 Vertaa k Sidowall Insfalatidi 2 co ia e 17 OR EEE EDER ONE EROEEEEDEEEOONEONERODNEEEONHEEDEEEO Vertical Sidewall Installation Flex Vent 18 Venting Components 47 Below Grade Installation ccccccccccseccseesseeees 18 Massachusetts Residents Onlly ssssseees 50 Vertical Through the Roof Application 19 Wala nt ar ccuc ccc ccdscecenvecntesesntensecetencedscssnedasscecesetercnees 51 Vertical Through the Root Installation 20 EFFICIOMCIES ccsssssssssssssssssesssesssesssssssssesesssesenesesessnssssess 54 Fireplace Installation eceecceeeeeeeeeeeeseeeneeeees 22 Check Gas Type ea 22 Gas Pipe to Fireplace Location Installation 22 Glass Frame Removal 24 Eyebrow Canopy Installation 25 Signature Command Insta
11. any gas control that has been under water 20306741 33 D 1 BLDV7 Series Gas Fireplace OPERATING INSTRUCTIONS SIGNATURE COMMAND OPERATING INSTRUCTIONS STOP Read the safety information above This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand With five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on page 38 If you do not smell gas go to next step Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready Press ON button Sparker will spark and pilot flame will light Once pilot flame is established the main burner flame will light automatically If the pilot will not stay lit after several tries turn the master switch to OFF and call your service technician or gas supplier OFF Master Switch Do qorr on gt E Command Center TO TURN OFF GAS TO APPLIANCE Turn master switch to OFF 2 Turn off all electrical power to the appliance if service is to be performed 34 20306741 OPERATING INSTRUCTIONS SIGNATURE COMMAND BLDV7 Series Gas Fireplace FEATURES RF Receiver To Thermopile ON OFF l To Sensor Comm
12. certified kit is used Aftermarket Completion of sale not for purpose of resale from the manufacturer E CERTIFIED TY BARRIER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference 20306741 11 14 Rev 1 BLDV7 Series Gas Fireplace CONTENTS Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty Important Safety Information 3 Final Installation Doaststesabcedsechaccsatcecstctdtactasceessssetedesdiees 30 Code Approval ienie naan 4 Hearth Brick Placement sei 30 Rockwool Placement cccccceeeeeseeeeceeteeeeeeees 30 Product Features peeatedg duvide E 5 Safety Barrier Installation ccccccccccccscscssesssssseseseee 31 Product Specifications 5 Log Placement 32 High Elevations iienaa Do ful grew Gt be ew A TSE O Gas Press
13. for snorkels 14 VENTING INSTALLATION INFORMATION edid IUSA Je JUOZUO 94 JO JSJUSO eU 0 UU JO 100 J SU WOJ4 UOISUBWIG BISA 57 from floor to center a 4 2 2 4 6 810 1214 1618 20 Horizontal dimension from the finished outside wall to the center of the pipe on the fireplace Figure 10 Rear Wall Venting Graph 20306741 VENTING INSTALLATION WARNING Horizontal sections of this vent system require a minimum of 3 clearances to combustibles at the top of the flue and 1 clearance at the sides and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration If the vertical rise is 71 2 ft or more only a 1 clearance is needed on top of any horizontal run Vertical sections of this vent system require a minimum of 1 clearance to combustibles on all sides of the pipe A minimum of 3 clearance to the top is required along horizontal length until flue Q pipe penetrates outside D wall Figure 11 Combustible Clearances for Vent Pipe 20306741 BLDV7 Series Gas Fireplace ae Aminimum 1 clearance flo to combustibles permitted all around flue at outside wall Vertical Rise Required Before Horizontal Run 15 BLDV7 Series Gas Fireplace VERTICAL SIDEWALL APPLICATION Minimum c
14. on a regular basis to make sure that no debris is interfering with the airflow Inspect entire venting system to ensure proper function GLASS DOOR Thoroughly clean the inside of the glass door after using the fireplace for ten hours Periodically clean the glass door as necessary When cleaning the glass remember e Do not remove the glass when hot Allow glass to cool before removal e NEVER use abrasive materials e Keep children and pets a safe distance away Never operate the fireplace without the glass door properly secured e Never operate the fireplace if the glass is broken Replace any glass that is chipped cracked or broken Replacement glass door assemblies MUST be supplied by the fireplace manufacturer No substitute materi als may be used e Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit on the inside of the glass should be cleaned off using a nontoxic non corrosive non abrasive mild cleaning solution Simply apply an adequate amount to the glass and wipe off with a damp cloth After all maintenance has been completed re install glass door and safety screen barrier 20306741 BLDV7 Series Gas Fireplace LOGS Leave logs installed in the fireplace for cleaning Vacuum surface of the logs with a brush attachment If logs must be removed for clea
15. wire connection is located off the 2 ft wire harness from the control box to the command center Fig ure 36 The connection is labeled Wall Switch Unplug the male and female connectors and connect the two 2 low voltage wires provided Run wire to desired location on wall Up to 50 ft of 18 ga wire may be used if necessary Attach wires to wall switch Mount the wall switch in to junction box and screw on cover WARNING Do not connect wall switch to 110 V circuit 27 BLDV7 Series Gas Fireplace SIGNATURE COMMAND INSTALLATION Optional To Junction Box PR in Fireplace UU 0 E ES Optional Wii D Light ite e Optional White Black E A Blower Black White gt E pine Black a nae Ak Green E Connector Pin To Control Board Input 300 Watt Max Each Optional A C Module Replaces 6V Adapter When Used Control Board RF Receiver J onorr Button Pilot i Ot 44 oonan 6V AC O Black Thermopile Adapter 0 G Red Thermopile Conversion Sensor NG LP bJ 1 Ignitor Sparker NOTE Wall switch wires mustbe 1 connected together if a wall switch is Plug in Connector
16. 0008 80D0008 80D0008 80D0008 80D0008 2 feet not shown A C Adapter 6 volt 1 80D0041 80D0041 80D0041 80D0041 80D0041 80D0041 Accessories Contemporary Reflective Glass Kit NOTE TSFSC must be used with SCS A C Module to control lights blower and aux Fuel Conversion Kits Signature Command System Natural Gas to LP BLDV300 Kit BLCK300CKPS BLDV400 Kit FBLCK400CKPS BLDV500 Kit BLCK500CKPS LP to Natural Gas BLDV300 Kit FBLCK300CKNS BLDV400 Kit FBLCK400CKNS BLDV500 Kit BLCK500CKNS 20306741 45 BLDV7 Series Gas Fireplace REPLACEMENT PARTS LOGS Ref Description BLDV300 BLDV400 BLDV500 1 Rear Log 1 20302139 74D0053 74D0053 e Let Uppertogas 4 na ramos 0058 46 20306741 VENTING COMPONENTS BLDV7 Series Gas Fireplace VERTICAL VENTING Description Mode Number Vertical Vent Termination Kits Vertical Vent Termination w Storm Collar 7TDVSKV flashing NOT included Vertical Vent Termination w Storm Collar 8 pack 7TDVSKV 8 flashing NOT included Vertical Vent Termination w 1 12 6 12 Flashing Storm 7TDVSKVA Collar and Ceiling Support Kit Vertical Vent Termination w 6 12 12 12 Flashing 7TDVSKVB Storm Collar and Ceiling Support Kit Vertical Vent Termination w Flat Flashing Storm Collar 7TDVSKVF and Ceiling Support Kit Twist Lock Pipe 20 Rigid Pipe single pack 7TDVP20 7FDVP30 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 7TDVP8 4 7TDVP12 4
17. 04 4DT 4 4D24 3 6 36 Pipe Length galvanized 46DVA 36 903 4DT 36 4D36 3 6 48 Pipe Length galvanized 46DVA 48 902 4DT 48 4D48 4 6 8 2 Pipe Extension galvanized 46DVA O8A 4DT AJ 4 6 16 Pipe Extension galvanized 46DVA 16A 4DT AJ14 5 6 45 Elbow galvanized 46DVA E45 945 4DT EL45 4D45L 6 6 90 Elbow galvanized 46DVA E90 990 4DT EL90 4D90L 7 6 Adjustable Roof Flashing 0 12 6 12 46DVA F6 943 4DT AF6 4DF 8 6 Storm Collar 46DVA SC 953 4DT SC 4F5C 9 6 1 Firestop 46DVA FS 963 4DT FS 4DF5 9 6 3 Firestop FS3 10 1 Vinyl Siding Standoff 46DVA VSS 950 4DT VS 4DVS 11 1 Restrictor Disk 45D0551 45D0551 1 Attic Insulation Shield 46DVA IS 6 Steep Roof Flashing 7 12 12 12 46DVA F12 943S 8 Horizontal Termination with 1 firestop BHRT 8 8 Flex Adapter Starter DVFFA 8 Reducer Adapter from 4 x 7 MBSPA 4DMA For more information about or instructions for the venting components referenced please contact the component manufacturer Selkirk Corporation www selkirkcorp com or 800 992 8368 Duravent www duravent com or 800 835 4429 Metal Fab Inc www metal fabinc com or 316 943 2351 20306741 49 MASSACHUSETTS RESIDENTS ONLY Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts Any residence with a direct vent produc
18. 20306741 BLDV7 Series Gas Fireplace FIREBOX FRAMING Firebox framing can be built before or after the appliance is set in place Construct firebox framing following Figure 2 for your specific installation requirements Refer to Figure 2 for firebox dimensions The framing headers may rest on the top of the firebox standoffs Do not bring headers below top of standoffs NOTE When planning your framing and installation keep in mind that your gas line will come in on the right side of the box as you are facing it and your electricity will come in on the left side The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height When the firebox is installed directly on carpeting tile or other combustible material other than wood flooring the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure BLDV7 Series Gas Fireplace FIREPLACE LOCATION Plan for the installation of your appliance This includes determining where the unit is to be installed the vent configuration to be used framing and finishing details and whether any optional accessories i e blower wall switch or remote control are desired Consult your local building code agency to ensure compliance with local codes including permits and inspections The following factors should be taken into consideration Clearance to side wall ceiling woodwork and windows Min
19. Control Board to Command Center ED Dn Ba ON HI r Master Switch ol not being used Es Plug in Connector Stepper Motor to Control Board Ground DC Power Green f Command Center Out Pilot Gas Tubing Plug in Connector th Control Board to oO Solenoid TO LE a Gas Gas In Le Figure 36 Signature Command Wiring Diagram Valve Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting fans to the main electrical power supply or performing service z O e gt lt O 28 Optional Wall Switch 20306741 SIGNATURE COMMAND INSTALLATION WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle BLDV7 Series Gas Fireplace WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical BLOTBLDVSC OPTIONAL BLOWER The BLOTBLDVSC Blowe
20. EMENT 1 Place rock wool on burner to provide glowing embers For best results pull the rock wool apart into pieces the size of a dime or smaller ta 2 Distribute one layer of rock wool to cover the burner Wee RE EM Figure 49 3 Place the logs on the burner Refer to Log Place ae ment below Light unit and after 15 minutes check Se Totipigie burner flame and glow Refer to Burner Flame in the We Cleaning and Maintenance section of this manual Cover with i i Rock Wool If the flame is blue and only in the center turn off unit and let cool After unit cools remove logs If the back holes are clear add more rock wool to the center of the burner Replace logs and check flame again Save left over rock wool to refresh when cleaning later Too much rock wool can disturb the flame and cause sooting on the glass or logs WARNING Do not use the entire bag of rock wool to cover the burner This could cause the flame to burn poorly and may lead to sooting Figure 39 Placement of Rock Wool on Burner 30 20306741 FINAL INSTALLATION SAFETY BARRIER INSTALLATION INSTRUCTIONS TL CERTIFIED NOTE A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier sha
21. ER run vent piping downward Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope Horizontal venting which incorporates the use of flex vent ing shall have an inclining slope from the unit of 1 25 mm per 24 610 mm There must not be any obstruction such as bushes gar den sheds fences decks or utility buildings within 24 610 mm from the front of the termination hood Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent termination area after snow falls and clear to prevent accidental block age of venting system When using snow blowers make sure snow is not directed towards vent termination area Location of Vent Termination It is imperative the vent termination be located observing the minimum clearances as shown on following page WARNING This fireplace must be vented to the outside The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance Each gas appliance must use a separate vent system Do not use common vent systems Failure to follow these instructions will void the warranty 11 BLDV7 Series Gas Fireplace TERMINATION LOCATION VENTING INSTALLATION INFORMATION INSIDE CORNER DETAIL Termination Locations VENT TERMINATION GO AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED
22. Groove Tab Figure 33 20306741 25 BLDV7 Series Gas Fireplace CHECK THE GAS TYPE AND PRESSURE 1 Check gas type The gas supply must be the same as stated on the appliance s rating decal If the gas supply is different from the fireplace STOP Do not install the appliance Contact your dealer immediately To ease installation a 24 610 mm flex line with manual shut off valve has been provided with on this appliance SIGNATURE COMMAND INSTALLATION ELECTRICAL WIRING General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junction box A C power supply Four 4 AA batteries are used for back up during power outages Install and attach 1 2 gas line onto shut off valve 3 After completing gas line connection purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks Use a solution of 50 50 water and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Tum unit to high Figure 34 After taking pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately
23. LP units never connect fireplace directly to the propane LP supply This burner system requires an external regulator not supplied Install the external regulator between the burner system and propane LP supply z 2 pam D lt x oO When using copper or flex connectors use only fittings approved for gas connections The gas control inlet is 3 8 NPT 20306741 FIREPLACE INSTALLATION WARNING Only persons licensed to work with gas piping may make the necessary gas connections to this appliance NOTE The gas line connection may be made using 1 2 rigid tubing or an approved flex connector Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI Z223 1 NFPA54 In Canada CSA B149 1 or 2 Installation Code Alisted manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 31 IMPORTANT Install main gas valve equipment shutoff valve in an accessible location The main gas valve is for turning on or shutting off the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces Approved Flexible Gas Line Tee Joint Sediment Trap Drip Leg Pipe Nipple Cap Figure 31 Gas Connection 20306741 BLDV7 Series Gas Firep
24. MING The fireplace must be secured to the floor and or to framing studs as shown in Figure 5 Use two 2 wood screws or masonry concrete screws to secure fireplace to the floor Use four 4 screws to attach fireplace to framing The side nailing flanges are 1 2 or 5 8 to accommodate different wall thickness Nailing Flange Screw Ra 2 Nailing Flange Figure 5 Securing Fireplace to Floor and Framing Studs Screws FINISHING MATERIAL NOTE Any remote wiring i e remote control wall switch and optional fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black painted face of the appliance It is permissible to bring combustible wall board to the top and side edges of the black painted face A 300 F minimum adhesive may be used to attach facing materials to the black surface If joints between the finished wall and the fireplace surround are sealed a 300 F minimum sealant material General Electric RTV103 or equivalent must be used 10 Drywall Support Tabs Do not use for framing or header SECURING THE FIREPLACE Framing Nailing Flanges 20306741 VENTING INSTALLATION INFORMATION WARNING Read all instructions completely and thoroughly before attempting installation Failure to do so co
25. N BEFORE YOU START Read this homeowner manual thoroughly and follow all instructions carefully Inspect all contents for shipping damage and immediately inform your dealer if any damage is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following e Fireplace Firebox and Burner System e Rock Wool e Log Set ITEMS REQUIRED FOR INSTALLATION e Phillips Screwdriver e Framing Materials e Hammer e Wall Finishing Materials Sawand orsabersaw Level e Electric Drill and Bits e Tee Joint e Pliers e Measuring Tape e Square e Pipe Wrench e Caulking Material Noncombustible e Fireplace Surround Material Noncombustible e Piping Complying with Local Codes Pipe Sealant Approved for use with Propane LPG Resistant to Sulfur Compounds WARNING Do not fill spaces around firebox with insulation or other materials This could cause a fire COLD CLIMATE INSULATION If you live in a cold climate seal all cracks around your appliance and wherever cold air could enter the room with noncombustible material It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests if the floor is above ground level NOTE Refer to cold climate pilot information on Page 40 for more information on standing pilot vs intermittent pilot options
26. Pilot Temp Shutoff Hold the ON A button 3 seconds when the master switchon the main burner is off RF Remote Receiver On Off Push the RF receiver On Off button on the control board Beep once for ON RF OFF and beep twice for OFF Learn Remote Transmitter Hold the OFF W button while turning on the master switch Beep twice then press any handheld remote button 6 hour Safety Shutdown setup Press the ON A button and OFF W button simultaneously Beep once for ON ON twice for OFF 36 20306741 OPERATING INSTRUCTIONS SIGNATURE COMMAND FUNCTIONS OPERATION Turning on the fireplace 1 Turn on the master switch and wait for a beep 2 Press the ON button on the Command Center or turn on wall switch Pilot will light and burner will come on High setting or last memory setting See Turning Off Fireplace below For memory feature Pilot Safety Lockout Function 1 If the pilot doesn t light after sparking for 30 seconds pilot trial lockout happens The LED on the Command Center flashes Green once every 2 seconds until reset 2 If the pilot flame is lost during normal operation the system will try three 3 times to relight after three 3 failures flame loss lockout happens The LED on the Command Center flashes Red Green once every 2 seconds until reset 3 Turning the master switch on the Command Center to the off position then ON again will reset the system Flame Height Control 1 Press the ON button on the Comman
27. Support Application Figure 27 Venting Supports 20306741 VENTING INSTALLATION Roof Pitch H feet Over 8 12 to 9 12 Over 9 12 to 10 12 Over 10 12 to 11 12 Over 11 12 to 12 12 H Minimum height from roof to lowest discharge opening of vent Figure 28 Minimum Chimney Clearance E BLDV7 Series Gas Fireplace Horizontal Overhang A 2 ft Min 2 ft Min Lowest Discharge Opening Termination A j Vent Storm Collar Flashing Concentric Vent Pipe a a 3 5 Sheet Metal Screws per Joint Sealant Figure 29 Roof Flashing 20306741 Storm Collar 1 Minimum Clearance to Combustibles 21 BLDV7 Series Gas Fireplace CHECK GAS TYPE Use proper gas type for the fireplace you are installing If you have conflicting gas type do not install fireplace See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit INSTALL GAS PIPING TO FIREPLACE BURNER SYSTEM LOCATION WARNING A qualified installer or service person must connect appliance to gas supply Follow all local codes INSTALLATION ITEMS NEEDED Before installing fireplace and burner system make sure you have the items listed below e External regulator e Tee joint e Pipe wrench e Equipment shutoff valve e Test gauge connection e Sediment trap recommended e Piping check local codes e Sealant resistant to propan
28. TALLATION INFORMATION BLDV7 Series Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors Inside Corner Outside Corner Combustible 6 152 mm Noncombustible 2 51 mm Balcony with no side wall Balcony ASR ORES N R DSJ q NY DS Combustible amp Noncombustible M Combustible amp Noncombustible 12 305 mm M 12 305 mm P 6 152 mm ESA LZ LS VOM VS SL SS F Combustible 6 152 mm Noncombustible 2 51 mm with perpendicular side wall d LIPO lt KY Alcove Applications E Min 2 51 mm for non vinyl sidewalls Min 12 305 mm for vinyl sidewalls O 8 2 4 m Min No of Caps Dmin Cmax Dmi of Termination caps x 3 Cmax 2 termination caps x Dactual 584 15 NOTE Termination in an alcove space spaces open only on one side and with an overhang is permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be a 3 914 mm minimum between termination caps 2 All mechanical air intakes within 10 1 m of a termination cap must be a minimum of 3 914 mm below the termination cap 3 All gravity air intakes within 3 914 mm of a termination cap must
29. TBLDVSC BLOTBLDVSC FBBLDV500CC BBLDV300CR FBBLDV500CR FBBLDV400VB FBBLDV500VB BLPB500 BLSOOLK RLSCB500 BLCS GLB O D S E GLB O D S E GLB O D S E _ mn Porcelain Blk Liner Kit not shown 10 Light Kit not shown Cover Kit not shown 2 Stone Kit not shown Glass Kit 2 25 lbs not shown BLDV400 500 Series require 2 bags _ di 8 8 8 E 10 20306741 43 REPLACEMENT PARTS BLDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM N XTi o 2 To o as 20306741 44 REPLACEMENT PARTS BLDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM lo FMNEEEEEE Description Qty 300NSC7 300PSC7 400NSC7 400PSC7 500NSC7 500PSC7 2 _ PiotAssemby 000006 8000007 soDo006 8000007 aoD0006 8000007 3 convois eopooie 2000019 sononse 8000019 8000018 8000019 a Command Cener 000005 000005 sonooos 8000005 8000005 8000005 5 Bumertube rDo60a 7400604 vanosoa 74d0604 7400604 7400604 6 Fexhose wih ShutofVave 1 900020 6900030 6900020 6900080 e9D0030 6900030 7 esr ff eoms cabanas 2018147 3305039 3305040 5700210 fs Bummer Assembly raD0090 7aDo09ex r4D0098K 74D009eK 74D0098K 74D0096K fs venus SSCS torte e026 contro 6001026 espirro 6901026 Wire Command Center Control Box 80D0008 80D
30. VERMONT CASTINGS GROUP BLDV7 Series Direct Vent Gas Fireplace Installation and Operating Instructions Models BLDV300 N P SC7SB BLDV400 N P SC7SB BLDV500 N P SC7SB AWARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is for use only with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a
31. and Center e Easy Access Function Operation and System Configura To Sparker ion a na NG LP e Operation Confirmation Fault Diagnostic Indications LED Conversion Buzzer e ON OFF HI Med Low Operation e Optional Wall Mounting Control Board 6 VAC MS Adapter To Command Center To Stepper Motor Control Board e Electronic Ignition To Valve e Pilot Lockout safety feature Electric Power Regeneration from Thermopile to save os ON battery enter Master Switch 6 hour Automatic Shut Down Option OFF e Convenient NG LP Gas Type Conversion e Standing Pilot Intermittent pilot Conversion e Previous settings Restoration Ability Memory Off e Uninterrupted Operation During Power Outage Automatic Battery Backup e ON OFF RF Remote Receiver e Optional Transmitter Learn Capability Battery Door Figure 42 AC Module Board Optional requires TSFSC Remote Signature Command System Components e Easy Snap on Design Embedded Compact 120 VAC Adapter with Auto Battery Back up Feature Remote Controlled 3 step Blower Lighting and On Off Auxiliary AC Outputs Transmitter Optional Three Brightness Settings for Lights Three Speed Control for Blower On Off Auxiliary Programmable Timer to turn blower on and off BATTERY INSTALLATION The Command Center uses four 4 AA batteries as back up for power outages The system can operate for approx imately six 6 months on battery power To Install Batteries not included
32. ation Remote Transmitter Learn Function Default OFF 1 The RF receiver button located on the Control Board must be in the on position before the learn function can begin Use paper clip to depress button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation Refer to Figure 57 for location 2 After the RF receiver is on holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter 3 After the above operation two beeps will be given and the green LED on the Command Center will flash for 10 seconds 4 During the 10 seconds press the OFF button on a transmitter to learn Another two beeps will be given to confirm a successful learning Refer to transmitter instructions for remote operations Shutting Off the Standing Pilot Temporary Shut Off To shut off the standing pilot for service or summer shut down press and hold the ON button on the Command Center for 3 seconds when the master switch is in the ON position and the main burner is off Note Pilot will resume the next time system is turned on Key Combinations for System Settings NOTE When On Off wall switch is used it must be in the On position to perform all system setups Intermittent Standing Pilot Hold the ON A button while turning on the master switch Beep once for Intermittent Pilot Setup standing pilot twice for intermittent pilot Standing
33. d 90 elbow Figure 18 Always install horizontal venting on a level A Figure 18 Horizontal Length Requirement FP1182 Step 6 Use appropriate length of pipe sections telescopic or fixed and install The sections which go through the wall are packaged with the starter kit and can be cut to suit if necessary 17 BLDV7 Series Gas Fireplace Step 7 Guide the vent terminations 4 and 7 collard into their respective vent pipes Double check that the vent pipes overlap the collars by 2 51 mm Secure the termination to the wall with screws provided and caulk around the wall plate to weatherproof As an alternative to screwing the termination directly to the wall you may also use ex panding plugs or an approved exterior construction ad hesive You may also attach the termination with screws through the inner body into the 4 vent pipe however for this method you must extend the 4 pipe approxi mately 6 152 mm beyond the outer face of the wall Support horizontal pipes every 36 914 mm with metal pipe straps VERTICAL SIDEWALL INSTALLATION FLEX VENT PIPE NOTE The 40 1016 mm flex vent is used for 90 bend after a straight vertical section 12 min then out the back wall Figure 20 Follow Steps 1 3 on Page 17 Step 4 Install the four 4 spacer springs on the 4 flex vent pipe When installing the spacer springs around the 4 pipe stretch the spring to approximately 15
34. d Center once to turn on the main burner with maximum flame height 2 Press the OFF button to decrease flame height The first Function Operator Power Up Flip the master switch to the ON position to power up the system Fireplace ON Press the ON A button on the Command Center or turn on wall switch to turn the fireplace on Fireplace Flip the master switch to the OFF o OFF position OR press the OFF W button 3 times OR for Memory Off hold the OFF W button 3 seconds or turn off wall switch Flame Height Press the ON A button once to turn on the Up fireplace with maximum flame height Flame Height Press the OFF W button to lower the flame Down height to Medium and Low 20306741 BLDV7 Series Gas Fireplace two presses will decrease the flame height to medium and low 3 The third press on OFF will turn off the main burner In standing pilot configuration the pilot will stay in inter mittent pilot configuration the pilot will be shut off Turning the Fireplace Off There are three ways to turn the fireplace off 1 Flip the master switch to the off O position This will turn the entire system OFF 2 Press the OFF button to Medium Low then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings wil
35. e LP gas supplied by installer e approved flexible gas line with gas connector if allowed by local codes not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP connections only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 30 Pointing the vent down protects it from freezing rain or sleet Use only new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code Section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted by local codes Gas piping system must be sized to provide minimum inlet pressure listed on data plate at the maximum flow rate BTU hr Undue pressure loss will occur if the pipe is too small z O lt O 22 FIREPLACE INSTALLATION 100 Ib min Propane LP Supply Tank External Regulator Vent Pointing Down FP1977 lt N lt N lt N lt N lt N lt NS Figure 30 External Regulator with Vent Pointing Down Propane LP Only For propane
36. g evenly with the pointed ends of the right and left front logs Also the notch on this log will match the middle tong on the grate Step 6 Small Twig 4 20306741 OPERATING INSTRUCTIONS SIGNATURE COMMAND BLDV7 Series Gas Fireplace FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of lie A This appliance is equipped with an ignition device which automatically lights the pilot Refer to the instructions B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS e Do not attempt to light any appliance e Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not function by hand do not try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and
37. g or the combustion air inlet 8kW the meter regulator assembly 3kW to any other appliance 12 30cm for appliances gt 10 000 BTU h 9 23cm for appliances gt 10 000 BTU h 3kW and lt 100 000 BTU h 30kW 3kW and lt 50 000 BTU h 15kW 36 91cm for appliances gt 100 000 BTU h 12 30cm for appliances gt 50 000 BTU h 30kW 15kW K Clearance to mechanical air supply inlet 6 1 83m 3 91cm above if within 10 3m horizontally L Clearance above paved sidewalk or 7 2 13m t 7 2 13m t paved driveway located on public property M Clearance under veranda porch deck or 12 30cm 12 30cm balcony In accordance with the current CSA B149 Installation Codes In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Codes Avent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if veranda porch deck or balcony is fully open on a minimum 2 sides beneath the floor 12 NOTE 1 Local codes or regulations may require different clearances 2 The special venting system used on Direct Vent Fireplaces are certified as part of the appliance with clearances tested and approved by the listing agency 3 Vermont Castings Group assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements 20306741 VENTING INS
38. he joints with three 3 sheet metal screws how ever this is not mandatory with twist lock pipe Figure 9 NOTE Sealant is not required to assemble fireplace venting Do not use silicone sealant at the inner flue exhaust connections To make it easier to assembly the joints we suggest put ting a lubricant Vaseline or similar on the male end of the twist lock pipe prior to assembly Male End e Edi Female End Ali A Screw Holes Figure 9 Twist lock Pipe Joints HOW TO USE THE VENT GRAPH The Vent Graph should be read in conjunction with the following vent installation instructions to determine the re lationship between the vertical and horizontal dimensions of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this di mension on the Sidewall Vent Graph Figure 10 locate the point intersecting with the slanted graph line 2 From the point of this intersection draw a vertical line to the bottom of the graph 3 Select the indicated dimension and position the fire place in accordance with same EXAMPLE A If the vertical dimension from the floor of the unit is 11 3 4 m the horizontal run to the face of the outer wall must not exceed 14 4 3 m EXAMPLE B If the vertical dimension from the floor of the unit is 7 2 1 m the horizontal run to the face of the outer wall must not exceed 7 2 1 m Refer to Page 18 for requirements
39. hour and are certified tural iate data plates naturakor propane gasu S68 appropriate data plates without deration for elevations up to 4 500 feet 1 370 e This appliance is not for use with solid fuels m above sea level e Ee appliance iS approvedslor Deurcom op bedsitinig For elevations above 4 500 feet 1 370 m in USA FOM installations installations must be in accordance with the current ANSI The appliance must be installed in accordance with local 7223 1 NFPA 54 and or local codes having jurisdiction codes if any If none exist use the current installation a Canada ol it incial and or local auth code ANSI Z223 1 NFPA 54 in the USA CSA B149in Manada please consult provincial andor toca author ities having jurisdiction for installations at elevations Canada above 4 500 feet 1 370 m e This appliance is mobile home appr oved e The appliance must be properly connected to a venting system GAS PRESSURES e The appliance is not approved for closet or recessed pecletene P Natura Propane LP GAS SPECIFICATIONS amp ORIFICE SIZE RE Min Input Orifice Fuel BTU h BTU h Size o Off Pilot On Knob 1 16 in BLDV7 Series Fireplace LP 24000 22 000 Millivolt Control shown Ignitor On Off RS Switch Hi Lo Knob 20306741 5 BLDV7 Series Gas Fireplace Rough Opening PRE INSTALLATION INFORMATION 7 Dia 4 Dia 1 2
40. imum clearances to combustibles must be main tained This fireplace may be installed along a wall across a corner or use an exterior chase Refer to Figure 3 for suggested locations Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing Refer to Venting section found in this manual for allowable venting configurations These units can be installed in a bedroom Refer to National Fuel Gas Code ANSI Z233 1 NFPA 54 cur rent edition the Uniform Mechanical Code current edition and Local Building Codes for specific installa tion requirements These units can be installed in a bathroom PRE INSTALLATION INFORMATION Pe yd lt Ne C SA a JE az Nu m es C E D pan 45 BY E E El mama a Figure 3 Possible Fireplace Locations A Flaton Wall B Cross Corner C Island D Room Divider E Flat on Wall Corner F Chase Installation Y 4 Minimum Island C and room divider D installation is possible as long as the horizontal portion of vent system X does not exceed 20 When you install your fireplace in D room divider or E flat on wall corner positions Y a mi
41. l openings through the roof In FP2304 all cases the opening Figure 25 must provide a mini Vertical Through the Roof mum of 1 inch clear Restrictor Part 69D3006 ance to the vent pipe i e the hole must be at least 93 4 x 93 4 248 x 248 mm 5 Place fireplace into position 6 Place firestop s or Attic Insulation Shield into position and secure Figure 26 7 Install roof support Figure 27 and roof flashing mak ing sure upper flange is below the shingles Figure 29 8 Install appropriate pipe sections until the venting is above the flashing Figure 29 9 Install storm collar and seal around the pipe 20 VENTING INSTALLATION Attic Insulation Shield 7DV1AlIS A Upper Floor gt ll l 11 l vt z 279 mm Ceiling Installation rs f FP1029 Firestop Spacer Nails 4 Figure 26 Place Firestop Spacer s and Secure 10 Add additional vent lengths for proper height Figure 28 11 Apply high temperature sealant to 4 and 7 collars of vertical vent termination and install If there is a room above ceiling level fire stop spacer must be installed on both the bottom ad the top side of the ceil ing joists If an attic is above ceiling level an Attic Insula tion Shield must be installed The enlarged ends of the vent section always face downward FP1184 Typical Roof Support Typical Ceiling Application
42. l resume To reset change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings Self Diagnostics Chart The Command Center has a self diagnostic LED enabling you to troubleshoot problems and potentially avoid a service call Please refer to the charts below for indicator reference Fa bind Conversion Gover Missing One RED rime Pilot Lockout trial One GREEN every 2 sec until manual reset Pilot Lockout flame loss One RED GREEN every 2 sec until manual reset Low Battery One RED every 10s continuously No or Low Thermopile Power Two RED every 10s continuously Learning GREEN Flashes every 1 sec for 10 sec AC Power On GREEN solid Pressure Switch Failure One RED every 2 sec until Power Vent Only manual reset Conversion Cover Missing 37 BLDV7 Series Gas Fireplace WARNING Turn off gas before servicing fireplace It is recommended that a qualified service technician perform these check ups at the beginning of each heating season BURNER PILOT AND CONTROL COMPART MENT Keep the control compartment logs and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year Make sure the burner porting pilot air opening and burner air opening are free of obstructions at all times PILOT FLAME The flames from the pilot should be visually checked as soon as the heater is installed and pe
43. lace A manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 31 z O gt lt x Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in clogged burner system valve We recommend that you install a sediment trap drip leg in supply line as shown in Figure 31 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burner system Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap collects moisture and contami nants and keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly Use pipe joint sealant that is resistant to liquid petroleum LP gas CSA Design Certified Equipment Shutoff Valve with 1 8 NPT Tap Natural Gas From Gas Meter 4 5 w c to 10 5 w c Pressure Propane LP From External Regulator 11 w c to 13 w c Pressure 23 BLDV7 Series Gas Fireplace GLASS FRAME REMOVAL NOTE If the safety barrier is in place you must first remove it before you remove the glass frame To remove the barrier simply lift up and pull out until the tabs are clear of their corresponding slots on the fire
44. learance between vent pipes and combus tible materials is 3 76 mm on top and 1 25 mm on the bottom and sides unless otherwise noted Refer to Page 15 When vent termination exits through foundations less than 20 508 mm below siding outcrop the vent pipe must flush up with the siding It is best to locate the fireplace in such a way that minimiz es the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace or the top of the Transition Elbow to the face of the outer wall Horizontal plane means no vertical rise exists on this por tion of the vent assembly The maximum number of 90 elbows per side wall in stallation is three 3 Figure 12 e If the min 12 rise with a 90 elbow is fitted directly on top of the first 12 section the maximum horizontal vent run before the termination or a vertical rise is 36 914 mm Figure 13 e If a 90 elbow is used in the horizontal vent run lev el height maintained the horizontal vent length is re duced by 36 914 mm Figures 13 amp 14 This does not apply if the 90 elbows are used to increase or redirect a vertical rise Figure 12 E 3x 90 IE Elbows IE _ 12 305 mm T Section Minimum L E Figure 12 Fireplace H Maximum Three 3 90 Collar T Elbows per Installation ia E FP1176 36 914mm 36 Max 12 305 mm 914mm Section
45. ll be replaced with the manufacturer s barrier for this appliance Any safety screen guard or barrier removed for servicing the appliance must be replaced prior to operating the appliance See parts list for model number 1 Remove screen from packaging 2 Align the four tabs on the sides of the screen frame two top two bottom Figure 40 with the correspond ing slots on the firebox Figure 41 3 Slide the screen down into the slots until it fits secure ly in place NOTICE It is the responsibility of the installer to ensure the barrier is affixed to the fireplace at the time of instal lation LR j 4 S5 Tabs two per side j Figure 40 20306741 BLDV7 Series Gas Fireplace HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING The safety screen barrier must be installed after the glass front is in place It is NOT a replacement for the glass and the unit must NOT be oper ated without the glass in place L lt Co ar d Ed rd Slot ENE ess E a Slots Qty 4 Two per side Figure 41 31 BLDV7 Series Gas Fireplace LOG PLACEMENT 1 Place the rear
46. llation 26 Check the Gas Type and Pressure 26 Electrical Wiring SCS 26 Junction Box Wiring a s 27 Command Center Wall Installation 27 Wall Switch Installation iii 27 Signature Command Wiring Diagram 28 Optional BIOWEIS reises desses i teeta aaaeeeaa 29 2 20306741 IMPORTANT SAFETY INFORMATION INSTALLER Please leave these instructions with the appliance BLDV7 Series Gas Fireplace OWNER Please retain these instructions for future reference WARNING Read this owner s manual carefully and completely before trying to assemble operate or service this fireplace Any change to this fireplace or its controls can be dangerous Improper installation or use of this fireplace can cause serious injury or death from fire burns explosions electrical shock and carbon monoxide poisoning This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs the fire place may not have been insta
47. lled properly Get fresh air at once Have the fireplace inspected and serviced by a qualified service person Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Propane LP gas and natural gas are both odorless An odor making agent is added to each of these gases The odor helps you detect a gas leak However the odor added to these gases can fade Gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not con vertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors To prevent performance problems do not use propane LP fuel tank of less than 100 Ibs capacity 3 If you smell gas e shut off gas supply e do not try to light any appliance e donot touch any electrical switch do not use any phone in your building e immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 Never install the fireplace e in a recreational vehicle 20306741
48. log 1 in place by sliding it over the rear pins on the right and the left Step 1 Rear Log 1 2 Place the right front log 3 over the burner and grate by matching the hole on the bottom of the log with the pin on the burner Also match the cut out on the bottom of the log with the bars on the grate NOTE When this log is in place pull towards the front Step 2 Right Front Log 3 3 Place the left front log 5 over the burner and grate by matching the holes on the bottom of the log with the pin on the burner Also match the cut out on the bottom of the log with bars on the grate NOTE When this log is in place the branch on this log will lay over the rear log on the left Pull log forward Step 3 Left Front Log 5 32 FINAL INSTALLATION 4 Place the right upper log 2 at an angle toward the burner by matching the rectangular notch on the bottom of this log with the rectangular protrusion on the right front log 3 The burned side of this log will point toward the burner Step 4 Right Upper Log 2 Place the left upper log 6 at an angle by matching the rectangular notch on the bottom of this log with the rectangular protrusion on the side of the left front log 5 The split end should point toward the front Step 5 Left Upper Log 6 6 Place the small twig 4 by having the small pointed end of the log toward the front of the fireplace and the fat end restin
49. m inspected annually by a qualified service person If needed have venting system cleaned or repaired Refer to Cleaning and Maintenance Page 44 11 Keep the area around your fireplace clear of combustible materials gasoline and other flammable vapor and liquids Do not run fireplace where these are used or stored Do not place items such as clothing or decora tions on or around fireplace 12 Do not use this fireplace to cook food or burn paper or other objects 13 Never place anything on top of fireplace BLDV7 Series Gas Fireplace 14 Do not use any solid fuels wood coal paper card board etc in this fireplace Use only the gas type indicated on rating plate 15 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 16 Do not obstruct the flow of combustion and ventilation air in any way Provide adequate clearances around air openings into the combustion chamber along with ade quate accessibility clearance for servicing and proper operation 17 When the appliance is installed directly on carpeting tile or other combustible material other than wood flooring you must set appliance on a metal or wood panel or hearth pad extending the full width and depth of the appliance 18 Do not use fireplace if any part has been exposed to or has been under wate
50. nimum of 4 clearance must be maintained from perpendicular wall and front of fireplace 20306741 CLEARANCES CLEARANCES TO COMBUSTIBLES WARNING Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance 71 Minimum Ceiling 13 Min Figure 4 Clearances From The Mantel Ceiling and Side Wall FP2333 NOTE When eyebrow canopy is used minimum clearance to combustibles is 21 4 maximum out from fireplace front at 71 2 minimum from opening Figure 4b When eyebrow is not used clearances to combustibles is 12 maximum out from fireplace front at 13 minimum from opening Figure 4 20306741 From Opening BLDV7 Series Gas Fireplace Combustible Material Area FP2334a Side of Fire place Opening e 3 45 Top View Figure 4a Mantel Clearances Combustible Breastplate 12 Max 3 4 Marble 1 3 Min T2 Min 1 Max Eyebrow Canopy gt 2 Max Figure 4b Mantel Clearance with Eyebrow Canopy BLDV7 Series Gas Fireplace SECURING THE FIREPLACE TO THE FLOOR OR FRA
51. ning handle carefully by holding gently at each end Gloves are recommended to prevent skin irri tation from ceramic fibers If skin becomes irritated wash gently with soap and water Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush i e clean dry paintbrush To place logs back in the fireplace see Log Placement found in the Final Installation section NOTE Do not use fluids to clean ceramic fiber logs ROCK WOOL Replace or add rock wool as required following installation instructions in the Final Installation section of this manual 39 BLDV7 Series Gas Fireplace TROUBLESHOOTING GENERAL TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1 The pilot and main burner Inner vent pipe leaking exhaust A Check for flue product leak Replace extinguish while in operation gases back into system defective pipe section Horizontal vent improperly Check horizontal venting piping is run pitched ning upward 1 4 per foot Do not run the pipe level or downward Improper vent cap installation C Check for proper installation and free dom from debris or blockage 2 Glass Soots Flame impingement on logs Install log set per the instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clean Check gas supply 3 Flame burn blue and lifts off A Insufficient oxygen being Ensure that the vent cap is installed burner gho
52. o CANADIAN INSTALLATIONS US INSTALLATIONS A Clearance above grade veranda porch 12 30cm 12 30cm deck or balcony B Clearance to window or door that may be 6 15cm for appliances lt 10 000 BTU h 6 15cm for appliances lt 10 000 BTU h opened 3kW 3kW 12 30cm for appliances gt 10 000 BTU h 9 23cm for appliances gt 10 000 BTU h 3kW and lt 100 000 BTU h 30kW 3kW and lt 50 000 BTU h 15kW 36 91cm for appliances gt 100 000 BTU h 12 30cm for appliances gt 50 000 BTU h 30kW 15kW window condensation C Clearance to permanently closed window 12 305mm recommended to prevent 12 305mm recommended to prevent window condensation D Vertical clearance to ventilated soffit 18 458mm 18 458mm located above the terminal within a hor izontal distance of 2 610 mm from the center line of the terminal E Clearance to unventilated soffit 12 305mm 12 305mm F Clearance to outside corner see next page G Clearance to inside corner see next page see next page H Clearance to each inside of center line 3 91cm within a height of 15 5m above 3 91cm within a height of 15 5m above extended above meter regulator assembly the meter regulator assembly Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to non mechanical air supply 6 15cm for appliances lt 10 000 BTU h 6 15cm for appliances lt 10 000 BTU h inlet to buildin
53. owering fuel consumption and reducing your carbon footprint Either mode benefits from the instantaneous battery back up so you never have to worry about a power outage NOTE The Signature Command System comes standard in the Intermittent Pilot mode so you must follow the in structions below to switch to Standing Pilot Mode if needed Intermittent Standing Pilot Setup Default intermittent 1 Holding the ON button on the Command Center while turning on the master switch will toggle between stand ing pilot and intermittent pilot 2 After the above operation one beep for standing pi lot or two beeps for intermittent pilot will be given as confirmation Six hour Safety Shutdown Option Default ON 1 The system comes preset from the factory with a six 6 hour shutdown from its last command of operation This is done to prevent the fireplace from continuing to operate if unattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may con tinue to operate unattended OPERATING INSTRUCTIONS SIGNATURE COMMAND 2 When the master switch is in the ON position pressing the ON button and the OFF button on the Command Center simultaneously will toggle between enabling and disabling the six hour shutdown option 3 After the above operation one beep for enabling the six hour shutdown option or two beeps for disabling the six hour shutdown option will be given as confirm
54. purchase Ceramic Fiber Logs BASIC WARRANTY Vermont Castings Group warrants the components and materials in your gas appliance to be free from manu facturing and material defects for a period of two years from date of installation After installation if any of the components manufactured by Vermont Castings Group in the appliance are found to be defective in materials or workmanship Vermont Castings Group will at its option replace or repair the defective components at no charge to the original owner Vermont Castings Group will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation Any products presented for warranty repair must be accompanied by a dated proof of purchase This Limited Lifetime Warranty will be void if the appliance in not installed by a qualified installer in accor dance with the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal re installation or transportation of defective parts on the appliance or 3 incidental or consequential damage All service work must be performed by an authorized
55. r Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control which as been submerged in water 19 Do not operate fireplace if any log is broken 20 Do not use a blower insert heat exchanger insert or any other accessory not approved for use with this fireplace 21 Do not operate the fireplace with glass door removed cracked or broken CODE APPROVAL Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for VENTED GAS FIREPLACE in the USA and Canada as follows LISTED VENTED GAS FIREPLACE TESTED TO latest edition BLDV300 ANSI 221 50 CSA 2 22 BLDV400 500 ANSI 221 88 CSA 2 33 STANDARDS A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 or Standard for Gas Equipped Recre ational Vehicles and Mobile Housing CSA 2240 4 IMPORTANT SAFETY INFORMATION amp CODE APPROVAL IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle Similar noises are found
56. r Kit requires the SCSACM A C Module and the TSFSC remote to install and operate this kit Refer to blower instructions for installation To Junction Box In Fireplace power supply or performing service The black and white wires on the AC box wiring harness are marked Blower Light and Aux It is important to use the wires marked Blower or the control will not work correctly jee Optional AC o E Module Optional WHITE BLACK AUX GREEN Blower 300w Max Figure 37 BLOTBLDVSC Blower Wiring Diagram BLOTBLDV OPTIONAL BLOWER Before installing the blower wire the receptacle into an electrical circuit This should be done before framing the fireplace Wire with minimum 60 C wire in accordance with prevailing codes Speed Control Figure 38 BLOTSDV Blower Wiring Diagram 20306741 E Optional HITE lo Light WHITE 7 4 _ 120VAC WHITE BLACK WHITE AKO AAA Connector Pin To Control Box Control Box o L iste 29 BLDV7 Series Gas Fireplace FINAL INSTALLATION HEARTH BRICK PLACEMENT Place the hearth brick centered in front of burner and slide back until it hits the stops on the right and left of burner ROCK WOOL PLAC
57. rances of 12 305 mm above grade level a snor kel kit is recommended It allows installation depth down to 7 178 mm below grade level The 7 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall Ensure the sidewall venting clearances are observed If venting system is installed below ground we rec ommend a window well with adequate and proper drainage to be installed around the termination area If installing a snorkel a minimum 24 610 mm vertical rise is necessary The maximum horizontal run with the 24 vertical pipe is 36 914 mm This measurement is taken from the collar of the fireplace or transition elbow to the face of the exterior wall See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24 610 mm 1 Establish vent hole through the wall Page 17 Figure 16 20306741 VENTING INSTALLATION 2 Remove soil to a depth of approximately 16 406 mm below base of snorkel Install drain pipe Install window well not supplied Refill hole with 12 305 mm of coarse gravel leaving a clearance of approximately 4 102 mm below snorkel Figure 21 3 Install vent system 4 Ensure a watertight seal is made around the vent pipe coming through the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars 6 Slide the snorkel into the vent pipes and secure to the wall 7 Le
58. rer for installation of the equipment and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system components and 2 Acomplete parts list for the venting system design or venting system d Manufacturer requirements Gas Equipment Venting System Not Provided When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions e Acopy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment all venting instructions all parts lists for venting instructions and or all venting design LIMITED LIFETIME WARRANTY POLICY LIFETIME WARRANTY The following components are warranted for life to the original owner subject to proof of purchase Firebox Combustion Chamber and Heat Exchanger FIVE YEAR WARRANTY The following components are warranted five 5 years to the original owner subject of proof of
59. riodically during normal operation The pilot flame must always be pres ent when the fireplace is in operation Figure 43 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermocouple or sensor and the other reaching to the main burner BURNER Inspect area around the injector Remove any lint or foreign material with a brush or vacuum BURNER FLAME The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal operation at full rate and after operating for about 15 to 30 minutes the flame should be yellow and slightly taller than the rear log Figure 44 If the flame is blue and only in the center turn off unit and let cool After unit is cool remove logs and check to make sure the back holes in the burner are not covered with rock wool If the back holes are clear add more rock wool to the center of the burner Replace logs NOTE The type of installation vent system configuration and wind effects may cause the flame patterns to vary 38 CLEANING AND MAINTENANCE Sensor Signature a Thermopile Command System Pilot Figure 43 Pilot Flame Figure 44 Burner Flame Appearance 20306741 CLEANING AND MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person Inspect the external vent cap
60. rizontal vented gas fueled equipment the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back up is installed on the floor level where the gas equipment is to be installed In addition the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS cer
61. s Do not pack the open air spaces with insulation or other materials This could cause high temperatures and may present a fire hazard Unless the vertical run is 7 feet or higher top vent units only the clearances for the horizontal run is 1 at the top 20306741 BLDV7 Series Gas Fireplace GENERAL VENTING Your fireplace is approved to be vented either through the side wall or vertical through the roof Only Vermont Castings Group venting components specifically approved and labelled for this fireplace may be used Flexible UL1777 listed venting may be used in any vent ing application where rigid direct vent components can be used All restrictions clearances and allowances that per tain to the rigid piping apply to the flexible venting Flex kits may not be modified Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer s approved flex to pipe adapters This may occur only if doing so does not violate any of the venting length height routing horizontal to vertical raito require ments or clearance considerations detailed in this manual Venting terminals shall not be recessed into a wall or siding Select the amount of vertical rise desired All horizontal run of venting must have 1 4 rise for every 12 of run towards the termination below 71 2 feet of vertical rise With 71 2 feet or more vertical rise off top of fireplace the horizontal run may run level NEV
62. s combustible or noncombustible cut opening to size Figure 16 For com bustible walls first frame in opening NOTE When using flex vent the opening will have to be measured according to the 1 2 13 mm rise in 12 305 mm vent run Combustible Walls Cut a 95 8 H x 95 8 W 244 x 244 mm hole through the exterior wall and frame as shown Figure 16 Noncombustible Walls Hole opening must be 71 2 191 mm in diameter Vent Opening for Combustible Walls 95 8 244 mm Min 4 95 8 244 mm Min t LU Fireplace Hearth Framing Detail Opening for Noncombustible Wall 71 2 Soe 190 mm FP2293 Figure 16 Fireplace Hearth Locate vent opening on wall Step 2 Secure firestop to the inside frame center in the 95 8 x 95 8 vent opening Step 3 Place fireplace into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 17 20306741 BLDV7 Series Gas Fireplace X Figure 17 Vertical Height Requirement FP1181 Step 4 Using appropriate length of pipe section s attach to fire place with three 3 screws Follow with the installation of the inner and outer elbow again secure joints with three 3 sheet metal screws Step 5 Measure the horizontal length requirement including a 2 51 mm overlap i e from the elbow to the outside wall face plus 2 51 mm or the distance required if installing a secon
63. service representative This warranty is expressly in lieu of other warranties express or implied including the warranty of mer chantability of fitness for purpose and of all other obligations or liabilities Vermont Castings Group does not assume for it any other obligations or liabilities in connection with sale or use of the appliance It states that do not allow limitations on how long an implied warranty lasts or do not allow exclusion of indirect damage those limitations of exclusions may not apply to you You may also have additional rights not covered in the Limited Lifetime Warranty Vermont Castings Group reserves the right to investigate any and all the claims against the Limited Lifetime Warranty and decide upon method of settlement IF WARRANTY SERVICE IS NEEDED 1 Contact your supplier Make sure you have your warranty your sales receipt and the model serial number of your Vermont Castings Group product 2 DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF This page intentionally left blank This page intentionally left blank BLDV7 Series Gas Fireplace Canada ENER QUIDE Look for the EnerGuide Gas Fireplace Energy Efficiency Rating in this brochure Based on CSA P4 1 09 EFFICIENCY RATINGS ENERGUIDE RATINGS FIREPLACE EFFICIENCY MODEL PERCENTAGE VERMONT DAL 1 CASTINGS GROUP 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com 54 20306741
64. six 6 months under normal use 3 A C power must be used to power the A C module blowers lights and AUX accessories if used with this fireplace Optional Accessory Requirements 1 This fireplace may be used with a wall switch wall mounted thermostat and or Signature Command wire less controls The command center control may be mounted on the wall with the use of the SCSWEK 15ft wall mount extension kit Pressure Inlet 2 WARNING Electrical connections should only be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local city and state codes The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the o p Pressure Outlet Figure 34 Signature Command Valve Pilot Adjust ment Screw National Electrical Code ANSI NFPA 70 latest edition and Canadian Electrical Code CSA C22 1 Z Q D lt oO Label all wires before disconnecting when servicing controls Wiring errors can cause improper and dangerous operation WARNING Do not use open flame to check for gas leaks 26 20306741 SIGNATURE COMMAND INSTALLATION JUNCTION BOX WIRING 1 This should be done before framing the fireplace Wire the receptacle into an electrical circuit Wire with mini mum 60 C wire in accordance wi
65. sting supplied properly and free of debris Ensure that the vent system joints are tight and have no leaks Ensure that no debris has been blocking the inner air intake at the bottom back of the combustion chamber Ensure that the glass is properly secure and latch 40 20306741 TROUBLESHOOTING BLDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION FAULT DIAGNOSIS ACTION Using Battery polarity wrong Re install batteries Make sure battery Command Install batteries and or plug in the AC board gt Change batteries Battery voltage low A Center and No beep in about the control 8 seconds board are connected by a 2 feet or 15 AC plug is plugged to Plu a g the AC plug to feet cable AC mains DOM AC mains Flip the master switch E a rocker switch to the The Sep Conn Onn Repair or replace the ON iti gt the AC board broken or AC Board position bent gt LED on the Command 8 L Center does not show Replace the AC Board 2 solid green 2 z Check power Replace the Control No bee Check NG LP Check valve ep Press the ON button on P conversian cai gt s
66. t must have a carbon monoxide CO detector installed in the residence Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position In addition a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts Flex line installation must not exceed 36 inches and must have a T shutoff valve NOTE REGARDING VENT FREE PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts In addition vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts Flex line installation must not exceed 36 inches and must have a T shutoff valve CARBON MONOXIDE DETECTOR REQUIREMENTS 2 Revise 10 8 3 by adding the following additional requirements a For all side wall horizontally vented gas fueled equipment installed in every dwelling building or structure used in whole or in part for residential purposes including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 Installation of carbon monoxide detectors At the time of installation of the side wall ho
67. th prevailing codes 2 Remove the external junction box cover by removing the screw from the side of the outside firebox wall Junction box was installed at the factory 3 The junction box cover has a factory installed romex style strain relief connector After connecting the wires route the wire leads through this connector Refer to the wiring diagram in Figure 35 120V AC es oe es e e 60Hz Factory Supplied Not Supplied Junction Box Figure 35 Junction Box Wiring Diagram COMMAND CENTER WALL INSTALLATION The command center may be mounted on the wall with the use of the SCSWEK Kit 15ft cable junction box wall cover Mount the junction box provided at the desired location on the wall Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction box to lower control area at bottom of fireplace Unplug the 12 cable from the com mand center Attach the connector to the pins from wire by pushing in to connector making sure to follow the color code on connector Plug the 15 ft extension cable into the 2 ft cable Remove command center from the fireplace and plug the other end of the extension cable into the command center Snap on wall cover provided and screw to junction box 20306741 BLDV7 Series Gas Fireplace WALL SWITCH INSTALLATION The wall switch
68. tified 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 a 1 through 4 b Exemptions The following equipment is exempt from 248 CMR 5 08 2 a 1 through 4 1 The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in the most current edition of NFPA 54 as adopted by the Board and 2 Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling building or structure used in whole or in part for residential purposes c Manufacturer requirements Gas Equipment Venting System Provided When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instructions provided by the manufactu
69. uld result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury property damage or loss of life INSTALLATION PRECAUTIONS Consult local building codes before beginning the installation The installer must make sure to select the proper vent system for installation Before installing vent kit the installer must read this fireplace manual and vent kit instructions Only a qualified installer service person should install vent ing system The installer must follow these safety rules e Wear gloves and safety glasses for protection e Use extreme caution when using ladders or when on rooftops Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system e Installation of any damaged venting component e Unauthorized modification of the venting system e Installation of any component part not manufactured or approved by Vermont Castings Group e Installation other than permitted by these instruc tions WARNING Always maintain minimum clearances around vent systems The minimum clearances to combustibles for horizontal vent pipe are 3 at the top and 1 at the sides and bottom of the vent system until the pipe penetrates the nearest vertical wall 1 required A 1 minimum clearance all around the pipe must be maintained at outside wall and on vertical run
70. upply go Board or the Command Center Or p connections h h no sound from the H Jand control throug A Command Center valve indicating pilot board solenoid open connections Sparking is happening No sparking on Check pilot Check Go through elsewhere under the the pilot connections grounding pilot re install replace the pilot Y Re install the Control Sparking doesn t The Control Board is having interference from the Board move it around continue surrounding metal Ground or change the Control Board y Sparking is not in the Pilot doesn t light Check gas supply Go through gt Eua gas Tow adjust sparker position or replace the pilot 1 z The sensor on the pilot iti Main burner doesn t Go through i Adjust sensor position light is not in the flame or replace the pilot pilot flame too small 20306741 41 BLDV7 Series Gas Fireplace FIREBOX COMPONENTS 42 TROUBLESHOOTING 20306741 REPLACEMENT PARTS BLDV7 Series Gas Fireplace FIREBOX COMPONENTS Control Cover 74D0119 20302587K 26D2128K Eyebrow Canopy Junction Box Assy not shown Accessories Field Installed Options T Stat Blower w Speed Control SCS Blower w Speed Control amp Time Delay Firebrick Set Cottage Clay Firebrick Set Cottage Red Firebrick Set Vintage Brown BLOTBLDV BLOTBLDV BLOTBLDV BLOTBLDVSC BLO
71. ures iai sata at seara ted 5 Operating Instructions SCS 33 Gas Specifications amp Orifice Size iiis 5 Operating Instructions iii 34 To Turn Off Gas To Appliance 34 Pre Installation Information 6 Feat res 35 Fireplace AMON SION SAO air ren 2 System Configuration SetUp oo 36 in Rat deat a Rac an keel aia E Cold Climate Opliolizs arantotvalinte anasncteaterts 36 eq E RE E EN he gg Key Combinations for Systems Settings 36 Cole Climate Melato ee N E oe te Functions Operation ren 37 Fireplace Framing CORRER RE RE SERSRE E cn RE REP TT 7 Self Diagnostics Chart 37 Fireplace Location nn 8 Cl aranc s 9 Cleaning and Maintenance cseeccseseeeteeneeeenees 38 E E dl owiehe A Burner Pilot and Control Compartment 38 Securing the Fireplace cseesssseseseeseseeeeneesens 10 Pilot Flanela ora ta di 38 Securing the Fireplace 10 Burner Flame RDNS acct tet ncuehiait Mitel cathe 8 38 Finishing Material ssisisassssitesrassstssessssisisasmairada 10 Vent System squaso sho rsssne nad sda fega sda a 39 Vent Installation cccccceesssesesseseesseesesseseessensesseesees 11 Glass DOOR forista Samoa re a 39 Installation Precautions sara 11 Logs dai dada aaa a a dn Tan a gia dia o ia A URGE a a adia da a aed 39 General Venting EEIN e fa RSRS
72. vel the soil so as to maintain a 4 102 mm clearance below snorkel Figure 21 Screws 7TDVSNORK 7 a Snorkel Firestop ea 7 Pipe a Jal 4 102 mm Clearance Min Window 24 610 mm Well Minimum A minimum of 24 610 mm ver tical pipe must be installed when using the 7TDVSNORK Kit BG402a A If the foundation is re cessed use recess brackets not supplied for securing lower portion Figure 21 Below Grade Installation Do not back fill around snorkel A clearance of at least 4 must be main tained between the snorkel and the soil of the snorkel Fasten Snorkel brackets to wall Foundation lt 4 first then secure Recess Wall to snorkel with Screws self drilling 8 x 1 2 sheet metal watertight Sheet Metal screws It will be Seal Around Screws necessary to ex P Pe BG401 tend vent pipes out as far as the Figure 22 protruding wall Snorkel Installation face Figure 22 Recessed Foundation 20306741 BLDV7 Series Gas Fireplace VERTICAL THROUGH THE ROOF APPLICATION This gas fireplace has been approved for Vertical installations up to 40 12 m in height Up to a 10 3 m horizontal vent run can be installed within the vent system using a maximum of two 90 elbows Figure 23 Up to two 45 elbows may be used within the horizontal run For each 45 elbow used on the horizontal plane the maximum horizontal length must be reduced by 18
73. where curtains furniture clothing or other flamma ble objects are less than 42 from the front top or sides of the fireplace e in high traffic areas e in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing ignition Fireplace will remain hot for a time after shutdown Allow surfaces to cool before touching 6 Young children should be carefully supervised when they are in the same room as the appliance Toddlers young children and others may be susceptible to acci dental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces 7 Donot modify fireplace under any circumstances Any parts removed for servicing must be replaced prior to operating fireplace 8 Turn fireplace off and let cool before servicing installing or repairing Only a qualified service person should install service or repair the fireplace Have burner system inspected annually by a qualified service person 9 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint and dust Turn off the gas valve and pilot light before cleaning fireplace 10 Have venting syste
74. with your furnace heat exchanger or car engine IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplace to give off some odor the first time it is burned This is due to the manufacturing process Please ensure that your room is well ventilated during burn off open all windows It is recommended that you burn your fireplace for at least ten 10 hours the first time you use it Place the fan switch in the OFF position during this time WARNING Never connect unit to private non utility gas wells This gas is commonly known as wellhead gas Improper installation or use of this fireplace can cause serious injury or death from fire burns explosions electrical shock and carbon monoxide poisoning NATIONAL FIREPLACE INSTITUTE NFI de CERTIFIED www nficertified org We recommend that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed 20306741 PRODUCT FEATURES BLDV7 Series Gas Fireplace PRODUCT SPECIFICATIONS HIGH ELEVATIONS WIS APP ance Has Pecnccehiled 9r USA Wl eter Input ratings are shown in BTU per
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung Smart Max Geosystems VS1000 - Geo JVC GY-HD250 User's Manual Liste des objectifs nutritionnels particuliers homologués (liste des CABINE DE DOUCHE SAUNA INSTRUCTIONS D`INSTALLATION 1 ステンレスユニットシェルフキッチン 取付・設置説明書 帆立補強パーツの EC400 (Español) Risco - Prosys Voice Module User Manual Bedienungsanleitung Formatkreissäge FKS 315VF Copyright © All rights reserved.