1. hot water heating system for WARNING heating single or multiple occupancy buildings 1 2 Observe the following symbols Symbols for identification of dangers and user instruc tions RISK TO LIFE AN Identifies possible dangers originating WARNINCGI from the product which might lead to seri ous injury or death if proper care is not taken RISK OF INJURY SYSTEM DAMAGE 1 3 1 AUTION Identifies potentially dangerous situations which might lead to medium or minor injuries or to material losses if proper caution is not followed WARNING USER NOTE Guidelines for the optimum use and set ting of the control s plus other useful in formation 1 3 Observe the following guidelines Property damage may occur if the boiler is not used properly Do not operate the boiler if damage is present WARNING Have the heating system installed by a qualified in staller service agency or gas supplier Have the installer explain the operation of the heating system Read this user manual thoroughly Buderus RISK TO LIFE due to neglecting your own safety in case of emergency such as with a fire Never put yourself at risk Your own safety must always take priority RISK TO LIFE from explosion of flammable gases If you smell gas there is a danger of explosion No open flame No smoking Prevent spark formation Do not operate electrical switches including telephones plugs or door bells Cl
2. the boiler in operation connects the electrical power and maintains and repairs the boiler Other important information Do not use this boiler if any part has been under wa ter Immediately call a qualified service technician to inspect the boiler and to replace any part of the con trol system and any gas control which has been un der water Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the boiler The venting system must be inspected yearly Re place any parts that show signs of deterioration from corrosion or any other sources The boiler must be inspected yearly by a qualified service agency The inspection must include the main burners pilot burner boiler flue vent collector and venting system Replace any parts that show signs of deformation from corrosion or other sources We reserve the right to make any changes due to technical modifications User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 Buderus 3 2 Product description The GC 124 Il and SP model boilers are low temperature atmospheric gas fired boilers The boilers consist of Ignition module only for GC 124 II model and Hon eywell aquastat Boiler jacket and front door Boiler block with insulation Gas burner The ignition module and aquastat monitor and control all electrical component
3. 7 747 000 510 07 2006 US For the user User manual Gas Boiler Logano GC124 II SP WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do nottouch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyou cannot reach your gas supplier call the Fire Department e Installation and service must be per formed by a qualified installer service agency or gas supplier Sey j CERTIFIED CTO NOTICE This manual must be retained for future reference Buderus Please read thoroughly before use 1 For your Safety The Logano GC124 II SP atmospheric gas boiler has been designed and constructed using the newest tech nology available User friendliness was taken into ac count during the design process Following the safety references and operating instructions will take advan tage of the economical and environmentally friendly de sign of your boiler gt WARNING 1 1 Correct Use A The Logano GC124 II SP atmospheric gas boiler is de signed to heat water for a
4. P Issue 07 2006 4 Taking the heating system out of operation 4 1 Normal system shut down 1 Turn ON OFF switch emergency shutoff switch to OFF position This shuts off power to the boiler and all of its components e g burner aquastat 2 Close gas shut off SYSTEM DAMAGE due to freezing fl CAUTION The heating system can freeze up in cold is weather if it is shut down Ta Leave the heating system switched ON 1 constantly as much as possible Protect the heating system from freezing by draining the boiler and water pipes at the lowest point Fig 10 System shut down 1 ON OFF switch emergency shut off switch 4 2 Emergency shut down procedures Perform this procedure in case of emergency 1 Never put yourself at risk Your own safety must always take priority Shut off main gas supply Shut down the heating system using the boiler emergency shutoff switch or the corresponding circuit breaker We reserve the right to make any changes due to technical modifications Buderus User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 11 Your installer Buderus BBT North America Corporation Bosch Group 50 Wentworth Ave Londonderry New Hampshire 03053 USA Tel 603 552 1100 800 Buderus Fax 603 421 2719 www buderus net BBT Thermotechnik GmbH D 35573 Wetzlar www heiztechnik buderus de info heiztechnik buderus de
5. he instructions for switching off gas supply to boiler gt Chapter 3 3 page 10 and inform your customer service technician or your gas company 7 747 000 511 15 1K Fig 6 GC124 SP boiler 1 Sight glass Fig 7 GC124 SP gas valve 1 Gas control knob shown in the ON position 2 Red pilot ignition button Buderus 3 3 Shutting off gas supply to boiler 1 Set thermostat optional to the lowest value 2 Disconnect heating system from the power supply before carrying out maintenance work 3 Open boiler front door 7 747 000 511 12 0K Fig 8 Open boiler front door 4 Turngas control knob clockwise to the OFF position Do not use excessive force 5 If necessary shut off main gas supply 6 Close boiler front door Flame roll out switch The boiler is equipped with a flame roll out switch If the venting system of the boiler is blocked the flame roll out switch will respond Do not try to turn on the boiler In form a qualified service company The venting system of the boiler must be checked for blockage and the flame roll out switch must be replaced The flame roll out switch is for one time use only Do not try to use it again Fig 9 Gas valve GC124 II left GC 124 SP right 1 Gas control knob shown in the ON position Buderus We reserve the right to make any changes due to technical modifications 10 User manual Gas Boiler Logano GC 124 II S
6. ight glass gt Fig 6 After lighting the pilot keep the red pilot ignition button pressed in for an additional minute gt Fig 7 Release red pilot ignition button gt Fig 7 The red pilot ignition button should move back and the pilot burner should remain lit If the pilot burner shuts off turn the gas control knob back to OFF and shut off the main gas supply Power done the heating system and contact your heating service contractor or gas utility company RISK TO LIFE AN due to poisoning by leaking gas WARNING Ifthe red pilot ignition button does not pop 13 14 15 16 17 18 We reserve the right to make any changes due to technical modifications User manual Gas Boiler Logano GC124 II SP Issue 07 2006 up when you release it you must proceed with the following steps When the pilot burner shuts off after re peated lighting attempts you must shut off the gas control knob to OFF to avoid spillage of gas Shut off main gas supply Contact your service technician or gas supplier immediately and have the fault repaired Turn gas control knob gt Fig 7 counterclockwise to ON position The gas control knob can only be set to ON if the red pilot ignition button is out gt Fig 7 Close boiler front panel Open main gas supply Turn on electric power to heating system Set thermostat to desired room temperature If the heating system does not start operating follow t
7. ight to make any changes due to technical modifications Buderus User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 5 3 1 Operating instructions for GC124 Il models STOP First read the safety instructions on gt page 2 start up warnings on gt page 5 of these instructions 1 Set thermostat to the lowest value 2 Disconnect the heating system from the power supply Shut off main gas supply 4 Open the boiler front door RISK TO LIFE AN Due to fire or explosion WARNING Never use excessive force when ad justing the gas control knob gt Fig 3 Adjust the gas control knob only by hand Never use a tool for adjusting the gas control knob e Ifyou can not turn the gas control knob by hand do NOT try to repair it Contact a qualified service organizati on at this point 5 Turn the gas control knob clockwise in the OFF position Do not use excessive force RISK OF LIFE A N due to ignition of flammable gases WARNING Wait5 five minutes until all gas odors have disappeared Check to see if any gas odors remain also at floor level In case gas odors are still present shut off gas supply shut electrical power to the boiler and inform the service organiza tion or local gas utility company 6 Ifyou do not smell any gases proceed to the next step Buderus 7 747 000 511 12 0K Fig 2 Removing front door of boiler Fig 3 Gas valve 1 Gas control k
8. nob shown in the ON position We reserve the right to make any changes due to technical modifications 6 User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 USER NOTE This unit is equipped with an automatic ig nition system which automatically starts the pilot burner Do not attempt to ignite it manually 7 Turn gas control knob counterclockwise to ON position Do not use force 8 Close boiler front door 9 Open main gas supply 10 Turn on electric power to heating system 11 Set thermostat to desired room temperature 12 If the heating system does not start operating follow the instructions for turning off gas supply to boiler gt Chapter 3 3 page 10 and inform your customer service technician or your gas company 3 2 Operating instructions for GC124 SP models STOP First read the safety instructions on gt page 2 start up warnings on gt page 5 of these instructions 1 Setthermostat to the lowest value 2 Disconnect the heating system from the power supply Shut off main gas supply Open boiler front door 7 747 000 511 12 0K Fig 4 Removing front door of boiler We reserve the right to make any changes due to technical modifications Buderus User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 7 RISK OF LIFE AN Due to fire or explosion WARNING Never use excessive force when ad justing the gas control knob gt Fig 5 Adjust the gas con
9. ose main gas valve Open doors and windows Warn other occupants of the building but do not use door bells Leave the building Call gas company and fire department from outside the building Information on the boiler room RISK TO LIFE due to poisoning Insufficient ventilation or combustion air availability may cause dangerous flue gas leaks or formation Make sure that inlets and outlets are not reduced in size or closed f faults are not corrected immediately the boiler must not be operated until all faults have been corrected FIRE DANGER due to flammable materials or liquids Make sure that there are no flammable materials or liquids in the immediate vicinity of the boiler e Maintain a minimum distance of 15 inches from the boiler We reserve the right to make any changes due to technical modifications 2 User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 RISK TO LIFE AN due to water damage WARNING Do not use the boiler if any part has been submerged in water Contact a qualified service technician to check and replace any components submerged in water SYSTEM DAMAGE A N due to freeze CAUTION Make sure the boiler room stays above freezing 1 3 2 Performing work on the heating system RISK TO LIFE A N from explosion of flammable gases WARNING Make sure that a qualified company in stalls the boiler connects gas and venting connections places
10. s of the boiler The boiler jacket prevents energy loss and acts as soundproofing The boiler block transfers the heat generated by the burner to the boiler water The insulation prevents ener gy loss Buderus GC124 Il hi lt Q 5 7 747 000 511 01 0K Fig 1 1 2 3 4 5 6 Logano GC124 Il and SP boiler Boiler front door Aquastat boiler temperature control Ignition module only for GC 124 II model Boiler block with insulation Gas burner Boiler jacket We reserve the right to make any changes due to technical modifications User manual Gas Boiler Logano GC 124 II SP Issue 07 2006 3 Start up instructions Read the instructions and warnings on gt page 2 before start up for your safety RISK TO LIFE AN due to not observing the start up instruc WARNING tions and resulting incorrect operation fthese instructions are not followed ex actly a fire or explosion may be caused with serious property damage or loss of life or serious injury Observe the start up instructions USER NOTICE Li GC124 Il only This boiler is equipped with an electronic ignition system which automatically will light the pilot burner Do not try to maunally light the pilot burner GC124 SP only This boiler is equipped with a pilot burner that must be lit by hand Please follow the instructions in gt Chapter 3 2 page 7 when lighting the pilot burner We reserve the r
11. trol knob only by hand Never use a tool for adjusting the gas control knob Ifyou can not turn the gas control knob by hand do NOT try to repair it Contact a qualified service organizati on at this point 5 Turn the gas control knob clockwise in the OFF position Do not use excessive force RISK OF LIFE A N Due to ignition of flammable gases WARNING Wait 5 five minutes until all gas odors have disappeared Check to see if any gas odors remain also at floor level In case gas odors are still present shut off gas supply shut electrical power to the boiler and inform the service organiza tion or local gas utility company 6 If you do not smell any gases proceed to the next step 7 Open main gas supply USER NOTE This unit is equipped with an pilot burner that must be ignited manually Follow the instructions below to light the pilot burner 8 Turn gas control knob gt Fig 5 clockwise to the PILOT position 9 Push and hold the red pilot ignition button gt Fig 5 in Buderus Fig 5 Gasarmatur GC124 SP 1 Gas control knob shown in the ON position 2 PILOT position 3 Red pilot ignition button We reserve the right to make any changes due to technical modifications User manual Gas Boiler Logano GC124 II SP Issue 07 2006 10 11 12 Light the pilot burner with a match using the furnished match holder Insert the lit match through the s