2. Select relevant treatment mode such as Hair Remove Skin Rejuvenate Now take Hair Remove mode for example show as follows Hair Remove k mi 3 IET Parameter record Parameter IPL switch and energy RF switch and energy FP Cooling System i 5 1 i an SE az Pema i er L TERES i i 1Onn 000000 D bee at w l Second pulse duration Pulse Interval Pulse Number The same as follows Hatr remove i a OF T SHF _ Rapid hair removal syste kas 2 ee N wakak ae nqWI Tirri prego Pulse width modulation Frequency JC N a 000000 How to use the OPT SHR I Clinic operation A Before treatment To the machine b Input enough water and make good water circulation before actual operation c Water source distilled water or pure water d Before the operation make sure probe cold Then it s able to start the operation if take operation under the state of no water circulation or hot probe the handpiece is easy to damaged e Inflammable and explosive things should be kept away from operating room such as stupefacient liquid and gas To the patients a Classification of skin it s safe and effective to the white brown or yellow skin b Clean skin to eliminate the perfume and cosmetics c Use digital camera for memory take photo from different orientations if necessary d If neces
3. Chart of Face treatment Comparative chart after Thread Vein treatment Comparative chart after Acne treatment Comparative chart afier Face Reparing treatment Comparative chart after Freckle removal amp skin rejuvenation treatment 9 PHYSIOLOGY of HAIR Hair is mainly composed of two parts Hair Trunk it is the visible part hardly no influence on hair growup Flair follicle is endermic tissue to determine hair growup Period of Hair Growup Z Growup Normally human being has 85 hair always in growing up Hair growup can keep2 6 years it will grow up 10cm every year but its length will not over Imeter usually 2 Transition After period of hair growup it will enter transition Transition normally will keep 1 2weeks During transition hair follicle will be shrinkened to be one sixth of normal hair length 3 Dormancy Dormancy is after Transition hair will not grow up but it also connected with hair follicle dermis nipple is in dormacy and will keep 5 6weeks Normally there is 10 15 hair in dormacy During course of laser hair removal it is important to choose proper hair grow up During growup mother cell of hair rapidly split melanin quantity is most melania develop in period of hair growup and will become a part of hair follicle it 1s extremely sensitive on laser We only can use this equipment to do hair removal during this time Part of body Proportion of Dormancy Den
4. itself automatically when you start the machine You need to turn on and turn off the machine repeatedly for 3 times and then start using it LEVEL OF EQUIPMENT a Level of motor protection 1 CLASS BF CLASS b Anti corrosive liquid general c Not allowed to use this machine in room that exists flanmable anesthetic and nitrous oxide d Operation manner continuous operation Theory OPT SHR is with new AFT technology Advanced Fluorescence Technology uses low and equal energy The special filter cut s 950 1200nm wavelength which is useless in treatment and absorbs water to make patient feel painless SHR stands for Super Hair Removal a technology for permanent hair removal which is having a sweeping success The system combines laser technology and the benefits of the pulsating light method achieving practically painless results Even hairs which until now have been difficult or even impossible to be removed can now be treated In Motion represents a breakthrough in permanent hair removal with light technology The treatment 1s more pleasant than with the conventional systems and your skin is better protected g F a dair folicles tem Hair folicle coagu Hair dispel Compared to normal IPL machines SHR OPT is much more professional Single pulse mode can emit energy averagely Multi pulse Single pulse Work Mode mode however multi pulse mode focus energy on first pul
5. methods a light crusting which will vanish after 2 3 weeks or an alteration of the sin s pigmentation which will disappear after 4 6 25 months are very rare Precautions to be taken before the treatment At least 1 week before the first treatment intense sun exposure or solarium visits should be avoided Hairs should not be waxed or plucked less than 6 weeks before treatment Shaving is permitted any time Areas to be treated should be shaved one day before the scheduled appointment Precautions to be taken after the treatment The skin s natural protection is highly weakened after this intense light treatment Therefore a high level of UV protection 30 50 in the form of suntan lotion should be applied for about 1 week After 1 5 weeks hair will fall out Shaving is possible any time but hair should not be plucked 26 amp Maintenance of Machine I precautions 1 No stress on the touch LCD prevent it from breaking up 2 Keep the handle clean It s not allowed to clean it with ethanol 3 The handle is fragile please do be careful when you pick up the headpiece 4 Change water 10 15 days make sure water circulate normally before you start the treatment H Analysis On Simple Malfunction AV 1 No power supplied Please don t worry You can DO AS following the sequence below to find out what the problem is 1 Check up whether there is power supplied from electrical source 2 Check up
6. OPT Hair Removal Machine VERITAS Pai iii it tt EET EET EF ERE TR TNT RN NR UU J ainahan N N ROR aaia aaia aaa aaao F amp Q BEAUTY User Manual Safety notices Safety of IPL SHR Any people who are eligible in using and maintaining can safely use this machine Any operators and his her assistants must know well the following safe notices and make sure both the operator and the customers are safe during the treatments a The machine will start inspection automatically after it is on b Adopt the close filter crystal of transferring light the IPL SHR can only emit from the front face c Independent electrical circuit it will automatically stop working if the energy is too high d The emergency switch is convenient when you are in emergency e The key switch can protect it from stolen because they can t start the machine without certain key Any intensive light without correct using will hurt people It can work out high voltage when working we suggest anybody who operates this machine should read this safety notices before using it For Operator it s possible to touch the intensive light So make sure you wear the 3 grade glasses For customer it is better if the operator Is trained eligible and arrange a proper treatment room for the customer It is even better if the customer knows the treatment theory and cooperates with the operator during the treatment He she must make sure wear the professional p
7. bling the successful treatment of dark skin removing achromous fine hairs What does the client feel during treatment Treatment with SHR is practically painless as opposed to treatment with the conventional IPL devices On areas with dense hair growth warmth from the light impulses is evoked and the light impulses may be felt to a much lesser extent than with laser or IPL Which areas can be treated Body hair can be removed on any part of the body It 1s recommended a test be performed on a small patch before the first treatment How many treatments are necessary Until now hair had to be treated during the growing phase 20 30 In the telogen phase stem cells are in a resting phase but can still successfully be treated with the SHR system Since growth cycles vary approx 8 treatments are usually necessary How long should the intervals between treatments be The hair growth cycle and the interval between treatments should correspond requiring spacing of approximately 6 8 weeks How much time is necessary for a treatment Depending on the size of the area to be treated the time varies from 15 to 30 minutes for a facial treatment and about 3 hours for both legs Will there be any side effects Skin Is more sensitive in some areas of the body than in others and redness can occur as a side effect It should disappear In a matter of hours but could potentially be as intense as a sunburn lasting a few days Contrary to conventional
8. e piece of water funnel and one piece of water tube About switch AN Emergency switch keep it bounce in working when press it downwards the machine will be power off immediately turn right to recover Man How to install this machine a Open the package when receiving the machine b Place the machine on flat ground c Check up whether good condition of machine from appearance make sure no damage in transportation PS let it takes several hours rest before test the machine 1 Good condition of machine but there s some water on the surface of the machine please wait till dry then input water to test In fact we do function test before shipment and output water after perfect performance Sometimes the water may spill but normally please do not worry about 2 After above operation Keep 22 C 28 C temperature and the humidity not more than 20 in the treatment room Finally input water and function test d Input water 1 Water source pure water or distilled water 2 Screw off the caps of water inlet and water spilt at the same time 3 Take advantage of water pipe and water funnel to input water I BITE EH haces 5 LLL LTT TTT TTT kisa ee LLL HR Hill ary Fr Be K E j 4 Draw out water pipe and water funnel After add full of water just need to close the cap of Water Outlet place the other two to a clear and safe area during treatment Close all of the
9. m occurs we will pass them to our technician our technician will give a satisfactory answer within 1 7 working days 3 Ifthe problem comes from the spare part within the warranty we could consider in changing the spare part to our client which could be sent with his her next order If the next order is uncertain we could pay freight cost to send the spare parts 4 Ifthe problem comes from the main device within the warranty we could advice our client to post the device back to our company for repair by ordinary post or we could re send a new one to our client If the cost of posting the problematic device back to BEST is more than the value of a new device BEST would take it into consideration according to the actual status apply to re send a completely new device back to our client B We won t supply maintaining guarantee if troubles as below a Disassembling the machine by self b Fall it without caution c Lack of reasonable keeping and protect d Not operate according to the user manual e Expendable reasons If changes of the design and specification of the machine we will not notice you in addition If any queries please feel free to contact with the local marketing company All m one we will try our best to serve you and also need your fully cooperation Thanks 28 Product name Purchase date deadline Seller Add Tel Customer Add Tel Repair date Reason of the fault Repair content 29
10. me avoiding skin burn _ f When ending the treatment or try to change another treatment part or parameter adjustment firstly release the button on the handpiece or pedal firstly avoiding electric shock by chance g It s can be adjusted the energy according to the actual conditions of the patients C Special Notices a Avoid sunlight and burn before and after the treatment could use the suntan lotion cream SPF gt 30 to avoid direct sunshine b Avoid chemical or mechanical stimulation before and after 1 week of the treatment c Do not take filled things or injection treatment before and after 2 weeks of the treatment d Avoid direct or indirect heat stimulation to the treatment area after 3 days of the treatment especially to those of high pigment deposit e If taking laser skin care treatment before please wait for 3 weeks at least and then do this treatment f After the treatment patients are not allowed to eat the foods of dark color or great pungent within two weeks such as the sauce coke seafood capsicum etc g It s not allowed insolation in sun before and after the treatment h It s not allowed that use any cosmetics after the treatment suggested that use the natural moisturize products 1 Please cooling the bad reaction area after the treatment like tumescence and causalgiase j After the operation make sure clean the probe k It s not allowed to operate the machine without professional operators
11. ple and damage the machine If the probe Is not cold or it even becomes hot please stop using this machine nn do not press the button on handle one press by one press or step the foot pedal step by step That will make skin gets different energies which will sure hurt the customer Others System alarm of water temperature The lowest system settings of water temperature is 25 degree the highest system setting of water temperature is 60 degree During 25 60 degree the machine works well If lower 25 degree or higher 60C now pulse output from the probe B In the process of treatment a Spread approximate 2 mm cooling gel in front the ears and below the chin Making test of 2 3 spots according to the former parameter designed After 3 5 minutes observe the reflection of skin to make sure the right treatment parameter However it needs to wait for a little longer time b When taking the treatment to the protruding parts in the bone structure like forehead mandible and cheekbone Appropriately adjust the RF energy based on different conditions of patients c During the treatment vertically slide the bipolar probe on skin with level force and observe whether it s touched well or not Overlapped shoot makes sure to good effects of treatment area d please continuously step the pedal or press the button on handpiece e Adjust the energy from low to high and step by step make sure not more than 2J each ti
12. rotective eye patch which protects his her eyes from burning About the treatment room there must be clear mark which shows using intensive light NOW MAIN WARNING Please make sure you will carefully read the following warning tips a We need to warn you that it has dangerous high voltage Anybody except technicians that authorized by our company can repair this machine Especially the inside of device e g electrical source cooling system optic organs and treatment head etc b Make sure the voltage of this machine is same with yours 110V or 220V c It will hurt both you and the machine if you repair it when it 1s still working we strongly warn you that you must turn off the machine and pull out the electricity line and then start repairing it d Keep the probe clean MAKE SURE there is no cooling gel inside the probe e Stop using the machine when the handpiece is leaking water if it 1s already on please close 1t immedlately WARNING ON INTENSIVE LIGHT a The intensive light is possible to hurt your eyes or cause fire and burnt so we suggest you wear the glasses b It will hurt the customer if you use too high energy or make too many shots in one certain treatment area c Do not directly see the intensive light or laser light even if you wear the protective glasses and eye patch d Do not point the treatment head to the air Point it to the treatment area when using and hang it on the bracket when you don t
13. sary use external anesthetic one hour before the treatment Please shave hair firstly under hair removal treatment f Spread the cooling gel on skin about 2 mm thickness g Wear eyepatch before actual option Note can not look at the intensive pulsed light directly or alarm to people s eyes such as keratitis cornea brushing off or even lose sight h forbidden to wear watch and necklace etc during the treatment To the operators a Adjust the right parameters b Touch the 2 on the LCD to start c Test the device working please shot the 3 first pulse to ground at beginning make sure even energy output in treatment d Wear glasses before actual option e forbidden to wear watch and necklace etc during the treatment f can not look at the intensive pulsed light directly or alarm to people s eyes such as keratitis cornea brushing off or even lose sight g Please do not optionally open the panel of the machine even power stopped in case high voltage danger h It must tighten up the screw caps of machine before movement 1 vertically slide the probe on skin and keep close to skin J Keep the machine rest every 2 3 hours continuously working k The handle is fragile please keep special care when hanging to the holder or in handle D Please do treatment from the lower energy at the beginning and adjust the energy according to actual conditions and turn to us for help Otherwise it will hurt peo
14. se which is very easy to burn patients SHR OPT filtered violet light and infrared light which will eradiate and length 640 12 40 WES SEN Canoe eke absorb water from target skin So SHR does not have any side effect to body Identified Idenfitied function makes operation Avallable Avallable handpiece simple and makes treatment safely DEC Make sure energy output accurate and Unavailable Unavailable same with the display all the time which Technology makes operation easy and safe hich l Peores OAE 1 10Hz Which acce erate operation speed and short a lot of time for treatment Stationary Work Stationary technology Moving IPL can use less time to do technology technology amp In motion treatment on back leg and arm technology Filters Wavelength Treatment 430 1200nm Acne removal 480 1200nm Age spots sun spots amp pigmentation removal skin reprvenation 30 1200nm Freckles removal Skin reprvenation S60 1200nm Whitening skin Skin reprvenation 580 1200nm Vascular removal fade melasma skin rejuvenation 640 1200nm Thick Hair removal 690 1200nm Soft Hair removal Note This machine only one handle with three standard filters 480nm 530nm 640nm Installation Components of the device Assembly parts Power line Water pipe Water funnel Professional protective glasses Professional protective eye patch Pictures ae one piece of power line a z on
15. sity cpress a period ona sm Mandible O Ww Se T Or 30 awek 6 3545 Bikiniarea 30 12wek 7 355 Leg 20 24wek 6 254 Eye Upper half face Upper eyelid lift and rise eyebrow Before Upper eyelid lift and rise eyebrow After Arround eyes wrinkle obvious and eyelid Upper eyelid and eyebrow lift obvious drooping before treatment wrinkle improvement after treatment 18 Eyebag obvious and tumidness After one year therapy the before before treatment eyebag improvement and smooth Lower half face Falin wrinkle improvement Before Falin wrinkle improvement After Falin winkle on the cheeks lower eye and lines of corners of the mouth both very deep Before Jaw and neck slack therapy Before Jaw and neck slack therapy After Two months after therapy both of them improved line of the jaw also three dimensional both have obvious slack form neck disappear turkey neck Firm the whole face Before Firm the whole face After Before Falin wrinkle area between eyebrows lower eye After 4 months therapy all lines lines of corner of mouth all obvi are improved obviously Ous Scar Therapy Before Scar Therapy After 1758 ee 28 Obvious scar concave holes After 4 months therapy they are before therapy improved obviously i Turgid Pox therapy After Turgid Pox therapy Before 20 Before therapy the patient sAfter therapy turgid po
16. three caps after turned off machine Note Change water every 10 15 days approximate e Handle Installation Function test a Turn on machine when show the first LCD display please do not do any other operation b Turn off machine PS This is to make sure good water circulation before normal operation It s allowed to operate only based on good water circulation How to know good water circulation inside machine 1 Generally you can hear water flow sound 2 Under machine power on the probe sapphire turn to cold after 3 5 minutes 3 from the observe window you can see the something rotate inside wy If the water doesn t cycle well or the probe does not cold there might be some air in the pump We suggest do as following a Pull the handle Turn on machine when show the first LCD display please do not do any other operation b Let the handle put the earth Lower than the machine Check the probe whether cooling well If no write the next step c Button the water injection until it spurt the water then turn off machine d Connect the probe well Turn on the machine Operation instruction of LCD controller HH When turning on the machine the screen will show as the picture one And then the system turn to L ega 1 ni 5 mad m Ph wie if Be S T SIS CI ah Hair Remove Rejuvenate V lt Remove red blood Acne treatment ud EE Me
17. use it C Safety of the electricity and equipment a Keep all the panels and cover board closed b There is high voltage inside the machine even when it is off So it is better not open the equipment if there is no need c Please make sure the electricity is off if you want to repair the machine d This machine is about 40kg in net weight it might hurt people if you move it in not proper ways So pls make sure you move it slowly and carefully a The temperature of objects will rise after absorbing light energy so please take actions to reduce the flanmable risk on treatment areas and surrounding areas b Do not use alcohol acetone or other flanmable things on skin before treatment You can just wash the skin with water or sometimes a little soap c If you use alcohol to disinfect the treatment head or any other parts please wait till dry and then start the machine otherwise it is dangerous SYSTEM SAFETY SETTINGS a Everybody in the operation room must know where the safety sets are and how to use them b Anybody who doesn t have our key is not able to start the machine c There is a red indicator light which will be on if you start the machine d Emergency button the red switch is used to switch off power when you come to any emergency Just press it and the machine will stop working next time you use the machine you need to turn this emergency button on AUTOMATICAL INSPECTION It will start inspecting
18. whether the power line is connected well 8 Check up if the emergency switch is on 4 Check up if the inside electricity line is connected well G Check up the fuse which could be pulled out at the bottom of hole for power plug AG 2 The probe is not cold Check up whether there s water in water tank 1 and make sure water circulates normally 2 Check up the direct power supply switch 3 The xenon lamp is not on a The lamp is exhausted the lamp broken down b Poor contact anode and cathode line c Sinmer board broken down 4 Only LCD screen displays but can t enter into the treatment menu Touch LCD screen broken down 27 After sale Service And Maintenance The term of maintaining guarantee is main device year and spare part 3 months from the date of purchasing according to the receipt Expendable is not included m it Others not included in maintaining guarantee or over the time we also supply to maintain and renew but need charges Please contact with the dealer if need change of purchasing the parts and easily expendable products A We will guarantee the quality of our equipment normally there is no quality problem 1 If there is a deficiency please email or call us on the reasons it would be best to dealt with by email or telephone Because some of the problems are caused by using the machine In a wrong way 2 We suggest the client to take photos of the area where the proble
19. xes face has serious turgid poxes obvioulsy loss improvement Acne therapy Before Acne therapy After After therapy acne obviously loss skin become smooth 21 COMPARISON of HAIR REMOVAL 22 Taboos who are not suitable to use this machine a Pregnant b Isolation In the sun c Sensitive to light or medicine or are taking medicine that sensitive to light d Using vitamin within 6 months e Not representative naevi or malignant pathological changes in the treatment area f Pacemaker or quiver dispelling device user g Herpes or trauma h Pimple record 1 People who accept Hirudin etc treatment should stop using it before 2 weeks j Severe diabetes patient high blood pressure sufferer and epileptic 23 Technical Parameter amp Packing List xx Technical Parameter Counter Handle 2000W S 2 000W Power supply 220V 50Hz or 110V 60Hz Packing List pes SS Ipes 24 Question amp Answer Which advantages does this have for you An optimal intensity can be achieved given that the same area ts treated multiple times with low energy impulses The treatment is more comfortable and the skin is better protected than with conventional methods How are different hair and skin colours affected Light skin with dark hair responds most favourably to the treatments In addition to targeting the melanin SHR technology affects the chromphore a protein located in the follicle ena