Home

MT9083 Series ACCESS Master

image

Contents

1. MT9083A2 057 1310 1550 1625 nm SM General purpose plus enhanced macrobend detection at 1625 nm MT9083A2 063 850 1300 nm MM 1310 1550 nm SM Best unit for contractors or anyone who installs or maintains hybrid networks Note Models noted feature user selectable enhanced range ER for measuring PON systems detecting faults in short time and high resolution HR for the shortest dead zone 3 Select Factory Installed Options Must be added as separate chargeable line items Model Order No Description MT9083A2 B2 C2 010 Protector option includes rubber bumpers display cover and shoulder strap ener Keesen he eA ee mmm mmm L on Without Protector option 010 With Protector option 010 Product Brochure MT9083 Series 13 4 Select Loss Test Set Options Optical Power Meter Must be added as separate chargeable line items Model Order No Description MT9083A2 B2 C2 004 SMF Optical Power Meter UPC only MT9083A2 B2 C2 005 SMF High Power Optical Power Meter UPC APC MT9083A2 B2 C2 007 SMF MMF Optical Power Meter UPC APC Visible Light Source Model Order No Description MT9083A2 B2 C2 002 Visible Laser Diode 5 Select Connector Types The ACCESS Master MT9083 can be optioned to feature up to three optical ports single mode OTDR multimode OTDR and an Optical Power Meter options 004 005 and 007 Selecting a single connector code below will populate a
2. Power Meter Specifications Standard on all models Standard Integrated Power Meter 6 through OTDR port Maximum Input 10 dBm Measurement Range 50 to 5 dBm Fiber Type Same as OTDR Optical Connector Accuracy 2 Setting Wavelengths Features Same as OTDR 6 5 1310 1550 1625 1650 nm Options 053 055 057 063 073 1310 1490 1550 1625 nm Options 056 058 Store reference loss table Option Number Fiber Type Measurement Range Loss Test Set Specifications Optional on all Models 7 18 Power meters 004 005 and 007 MT9083A2 B2 C2 004 Single Mode 10 uim 125 um G 652 PC only for UPC connector 50 to 23 dBm MT9083A2 B2 C2 007 Single Mode 10 uim 125 um G 652 Multimode 62 5 um 125 um 67 to 6 dBm MT9083A2 B2 C2 005 Single Mode 10 uim 125 um G 652 43 to 30 dBm Wavelength Range 750 nm to 1700 nm 1200 nm to 1700 nm Setting Wavelengths Optical Connector 850 1300 1310 1383 1490 1550 1625 1650 nm 1310 1383 1490 1550 1625 1650 nm EHIME Feat USBS ECK Universal uses MA9005B adapters Universal uses LP XX adapters same as OTDR Accuracy 3 5 Modulation CW 270 Hz 1 kHz 2 kHz Features Store reference loss table Environmental Operating temperature and humidity 0 to 50 C lt 80 non condensing Central Wavelength Optical Output Output Optical Fiber Optical Connector Laser Safety 4
3. 01530 VANTAA Finland Phone 358 20 741 8100 Fax 358 20 741 8111 e Denmark Anritsu A S Kay Fiskers Plads 9 2300 Copenhagen S Denmark Phone 45 7211 2200 Fax 45 7211 2210 e Russia Anritsu EMEA Ltd Representation Office in Russia Tverskaya str 16 2 bld 1 7th floor Russia 125009 Moscow Phone 7 495 363 1694 Fax 7 495 935 8962 e United Arab Emirates Anritsu EMEA Ltd Dubai Liaison Office P O Box 500413 Dubai Internet City Al Thuraya Building Tower 1 Suit 701 7th Floor Dubai United Arab Emirates Phone 971 4 3670352 Fax 4971 4 3688460 e India Anritsu India Private Limited 2nd amp 3rd Floor 4837 1 Binnamangla 1st Stage Indiranagar 100ft Road Bangalore 560038 India Phone 91 80 4058 1300 Fax 91 80 4058 1301 e Singapore Anritsu Pte Ltd 11 Chang Cham Road 404 01 Shriro House Singapore 159640 Phone 65 6282 2400 Fax 465 6282 2533 e P R China Shanghai Anritsu China Co Ltd Room 2701 2705 Tower A New Caohejing International Business Center No 391 Gui Ping Road Shanghai 200233 P R China Phone 86 21 6237 0898 Fax 86 21 6237 0899 e P R China Hong Kong Anritsu Company Ltd Unit 1006 7 10 F Greenfield Tower Concordia Plaza No 1 Science Museum Road Tsim Sha Tsui East Kowloon Hong Kong P R China Phone 852 2301 4980 Fax 852 2301 3545 e Japan Anritsu Corporation 8 5 Tamura cho Atsugi shi Kanagawa 243 0016 J
4. 2013 02 05 14 31 30 VIP Test Result mee Fig 12 PDF Report Specifications e MT9083A2 B2 C2 ACCESS Master Common Specifications Dimensions and Mass Display Interface Data Storage Power Supply Power Saving Functions Dimensions 270 W x 165 H x 61 D mm 10 6 x 6 5 x 2 4 inches Mass 1 6 kg 1 9 kg including battery Dimensions 284 W x 200 H x 77 D mm 11 2 x 7 9 x 3 inches Mass 2 6 kg including battery 7 inch TFT LCD 800 x 480 with LED backlight Indoor Outdoor type USB 1 1 Type A x 1 memory Type B x 1 USB mass storage Internal memory 440 MB up to 1000 traces External memory USB up to 30 000 traces with 512 MB 12 V dc 100 V ac to 240 V ac Allowable input voltage range 90 V to 264 V 50 Hz 60 Hz Type Lithium ion Operating Time 12 hours Telcordia GR 196 CORE Issue 2 September 2010 Recharge Time 5 hours power off Backlight off Disable 1 to 99 minutes Auto shutdown Disable 1 to 99 minutes Without Protector Option 010 With Protector Option 010 Vertical Scale 0 13 0 33 0 65 1 3 3 25 6 5 13 dB div IOR Setting 1 400000 to 1 699999 0 000001 steps Units km m kft ft mi Languages User selectable English Simplified Chinese Traditional Chinese French German Italian Korean Portuguese Russian Spanish and Swedish contact Anritsu for availability of others Sampling Points Normal 5001 High
5. SM ve 1500000 8 249334m 12909 OR 10km RES 2001 at NA GN EREN 5 E On gei Tat ES SE Ji Ne s i A gt B 02009km Ren ess PW i00es ER AVG 253052 Fig 1 Typical PON 1 x 64 count System Measurement from the customer premise The MT9083 Series Enhanced Range Mode and a Pulse width of 100 ns provides excellent dynamic range while not compromising deadzone resolution to clearly display multiple high loss splitters Product Brochure MT9083 Series 3 Designed with the Features that Matter Most When buying products you tend to choose ones that are innovative and from established companies When you need to install and maintain optical networks this should also apply With over 50 years of combined OTDR design Anritsu delivers the features that matter Having been in the test and measurement business for a long time we understand that things like performance portability reliability easy operation and of course price are important Quick Startup The ACCESS Master is ready for measurement about 15 seconds after power on so productive work can start immediately Long Battery Life Since AC power is not always available where you need it especially at fiber pedestals the MT9083 typically provides up to 12 hours of operation on a single charge This coupled with an optional car cord for cigarette lighter operation guarantees the MT9083 is ready when you are Portable With its light weight design and
6. density 20001 or 25001 Very high density 100 001 or 150 001 Sampling Resolution 5 cm min Reflectance Accuracy Single mode 2 dB multimode 4 dB Distance Accuracy 1 m 3 x measurement distance x 10 5 marker resolution excluding IOR uncertainty Distance Range Single mode 0 5 1 2 5 5 10 25 50 100 200 300 km Multimode 0 5 1 2 5 5 10 25 50 100 km Testing Modes Fiber Visualizer Provides end break location end to end loss fiber length easy graphical summary PDF report PDF viewer Standard OTDR User selectable automatic or manual set up Construction OTDR Automated multi wavelength testing Light source Stabilized Light source CW 270 Hz 1 kHz 2 kHz output Loss test set optional Power meter and Light source Connector Video Inspection Probe Visual fault locator optional Visible red light for fiber identification and troubleshooting Fiber Event Analysis OTDR Trace Format Other Functions Environmental Conditions EMC LVD Auto or manual operation displayed in table format User defined PASS FAIL thresholds Reflective and non reflective events 0 01 to 9 99 dB 0 01 dB steps Reflectance 70 0 to 20 0 dB 0 1 dB steps Fiber end break 1 to 99 dB 1 dB steps Number of detected events up to 99 Macrobend detection Telcordia universal SOR issue 2 SR 4731 Real time sweep 0 15 sec Loss modes 2 point loss dB km 2 point LSA splice
7. m lt 80 cm typ Deadzone Backscatter IOR 1 500000 lt 3 8 4 3 m lt 3 8 4 3 4 8 m Deadzone Backscatter lt 5 5 5 m lt 5 5 5 6 5 m lt 6 6 5 6 5 m lt 6 6 5 7 5 m lt 7 7 5 7 5 8 5 m lt 5 5 5 m lt 4 5 m 3 4 m typ Deadzone Backscatter 9 lt 5 5 5 m lt 5 5 5 6 5 m lt 6 6 5 7 5 m lt 5 5 5 m lt 4 5 m 3 4 m typ Laser Safety 4 IEC 60825 1 2007 CLASS 1M option 053 055 056 057 058 063 073 21 CFR1040 10 Excludes deviations caused by conformance to Laser Notice No 50 dated June 24 2007 4 HR High Resolution mode for Short dead zone 10 ER Enhanced Range mode for PON measurement 5 25 C Pulse width 1 us all except 850 nm 1300 nm 850 nm 1300 nm 100 ns 11 6 Pulse widths 20 us Options 053 055 056 057 058 063 073 1310 nm 12 1550 nm at Distance range 100 km Pulse width 4 us Options 063 1300 nm at Distance range 25 km 13 Pulse width 500 ns Options 063 850 nm at Distance range 25 km 14 Averaging 180 sec SNR 1 25 C 7 Dynamic range one way back scattered light SNR 1 The level difference between the RMS noise level and the level where near end back scattering occurs Level Distance SNR 1 8 Pulse width 3 ns Options 053 055 056 057 058 063 073 Return loss 40 dB 25 C Refer to the figure below 9 Pulse width 10 ns return loss
8. user friendly dimensions the MT9083 is perfect for the outside plant environment and can easily be managed with one hand The shoulder strap part of the protector option further increases portability when travelling from the truck to the testing site Rugged The MT9083 features a solid casework with no fans or vents to keep dust or moisture from entering the unit In addition the protector option MT9083A2 B2 C2 010 includes rubber bumpers and a display cover for additional protection from those minor mishaps Generous Data Storage With the ability to store up to 1 000 traces in internal memory and up to 30 000 via a USB device the MT9083 offers plenty of storage for collecting and managing data No Experience Required With the ACCESS Master the experience is built in With specialized testing modes automatic parameter selection PASS FAIL indicators as well as features to virtually eliminate the chance to get bad results the MT9083 can make anyone seems like a 20 year veteran Let it help you master your network Easy drag and drop File Transfers When the MT9083 is connected to a PC via a USB cable the internal memory of the ACCESS Master can be directly accessed Data can be selected dragged and dropped into the PC memory greatly simplifying file transfers The MT9083 also supports use of USB memory sticks T o 4 Product Brochure MT9083 Series Common OTDR Data Format The MT9083 suppo
9. with just one unit Standard Stabilized Light Source The OTDR port also functions as a stabilized light source providing continuous wave 270 Hz 1 kHz and 2 kHz modulations for easy fiber identification This is standard equipment on all single mode models a chargeable option on most other OTDRs Standard or Optional Integrated Power Meter In the base unit the OTDR port also functions as an integrated power meter for verification of optical power levels Additional power meter options are available for higher power transmissions and loop back testing Visual Laser Source for Easy Fault Location and Fiber Identification A Visible Light Source is useful for tracking down bad connections splices and fiber management issues such as macrobends The optional Visible Light Source is factory installed in the MT9083 and features up to 5 km 3 miles of operation Remote GUI Function The MT9083 can be operated PC via LAN Ethernet network without any additional software installed A PC is shown OTDR screen and can operate them using a mouse on PC You can operate far end MT9083 easily USB Ethernet converter Con 3 This function is required to use USB Ethernet Converter J1480A it s needed to connect USB Port A on the MT9083 series Password Protection Feature A password protection feature has been added to the MT9083 When you use this feature users will be required to enter a password as soon as the syste
10. 42 dB MT9083C2 Ultra high performance enhanced range with full 1 x 128 PON support up to 46 dB MT9083 Series MT9083A2 B2 C2 ACCESS Master 850 1300 nm OTDR for Multimode Fiber 1310 1490 1550 1625 1650 nm OTDR for Single Mode Fiber d 20 d 2 Product Brochure MT9083 Series Anritsu is now pleased to announce the enhanced MT9083A2 B2 C2 models The ACCESS Master MT9083x2 now features a 7 inch widescreen TFT LCD display for use both indoors and outdoors enhanced battery operation time up to 12 hours increased operating temperature range 10 to 50 C and new short cut function keys Enhancements e Larger 7 inch higher resolution 800 x 480 display with LED backlight e Longer battery operation time Up to 12 hours e Wider operating temperature range 10 to 50 C e New shortcut keys to simplify operation quickly change between trace and event table or access set ups and mass storage e Lighter now only 2 6 kg 5 7 Ibs Enhanced Model Optimized for Verifying PON Splitters Up to 1 x 128 Count Many OTDRs claim to be able to test splitter based passive optical networks PON but the MT9083 delivers in a way others wish they could With its high dynamic range and quick data acquisition the MT9083 provides unparalleled resolution of single or closely spaced cascaded splitters up to an industry leading 1 x 128 count Sette D 00000 Nm A 22024 amp m Ptloss Wi 150mm
11. 55 dB Deviation 0 5 dB 25 C Options 053 055 056 057 058 063 073 All except 850 nm 1300 nm Pulse width 3 ns return loss 40 dB Deviation 0 5 dB 25 C Options 063 850 nm 1300 nm A Fresnel reflection 42 Back scattered light 10 Product Brochure MT9083 Series Pulse width 100 ns ER Mode Distance range 100 km Averaging 180 sec SNR 1 25 C Typical Subtract 1 dB for guarantee At measurement of 50 um 125 um MM Fiber the dynamic range drops by about 3 0 dB At 1 65 um With background light 1 31 um 1 55 um 19 dBm CW light Safety measures for laser products This product complies with optical safety standards in IEC 60825 1 21CFR1040 10 and 1040 11 the following descriptive labels are affixed to the product THIS PRODUCT COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO 50 DATED JUNE 24 2007 Light Source Specifications Standard on all models 1 Stabilized Light Source through OTDR port Wavelength 17 Spectral Width 17 Same as OTDR lt 5 nm 1310 nm lt 10 nm 850 1300 1490 1550 1625 nm lt 3 nm 1650 nm Wavelength Accuracy 850 1300 1310 1490 1550 1625 nm 30 nm 1650 nm 5 nm Fiber Type Same as OTDR Optical Connector Same as OTDR Output Power 17 5 11 5 dBm Output Stability 18 10 1 dB Modes of Operation 9 CW 270 Hz 1 kHz 2 kHz Laser Safety Same as OTDR
12. 642 Total Less 8 ORL d8 ine MEUM 37 0090 40 783 Fig 6 Easy to understand graphical summary Full report type Simple report type Fig 7 PDF report generation Fiber Los Re ecarce 34 0 e8 160 abu ogre 11346 1 3046 A Fig 8 PDF Viewer Simple Operation To simplify testing the MT9083 features dedicated measurement modes via the top menu to automate and simplify the task at hand Fig 9 Dedicated measurement modes simplify testing for any skill level General OTDR Testing For those who have more experience or would like to perform more advanced testing STANDARD OTDR mode allows the user to set all parameters and compare traces manually automatically or somewhere in between Optical Fiber Construction and Certification When final cable acceptance is the task at hand CONSTRUCTION mode greatly simplifies operation through its innovative wizard Select the required testing wavelengths number of fibers and file naming scheme and construction mode acts as the project manager guiding the user through the testing while ensuring consistency with testing parameters and filenames virtually eliminating user induced errors and mi
13. Anfritsu Product Brochure MI9083 Series MT9083A2 B2 C2 ACCESS Master 850 1300 nm OTDR for Multimode Fiber 1310 1490 1550 1625 1650 nm OTDR for Single Mode Fiber Sa EUM aL jm rte Aan it roe Z re LE O O Brei NL Ee ND X All in one Solution that Reduces Testing Times to Install and Maintain FTTx CATV LAN Access and Metro Networks 850 1300 nm OTDR for MMF 1310 1490 1550 1625 1650 nm OTDR for SMF MT9083 SERIES ACCESS MASTER OVERVIEW Optical fibers are a key technology in today s modern communications systems including access networks such as FTTx CATV and optical LANs Moreover optical fiber technologies are playing increasingly important roles in mobile communications and digital broadcasting systems Technicians maintaining these diverse systems are forced to carry a large variety of test equipment on site including OTDRs Light Sources Optical Power Meters Visible Light Sources etc On the other hand fiber construction requires measuring instruments with different functions and performance As an example FTTx access networks use single mode SM fiber whereas optical LANs use multimode MM fiber In addition core and backbone networks utilize long fibers while optical access networks use short fibers both requiring different types of measuring instruments with different performance But now Anritsu s new line of MT9083 ACCESS Master OTDRSs solves all these problems by providing all the measurem
14. Environmental Visible Light Source Option 002 650 nm 15 nm at 25 C 0 3 dBm CW 10 um 125 um SMF ITU T G 652 2 5 mm universal IEC 60825 1 2007 CLASS 3R 21CFR1040 10 and 1040 11 Excludes deviations caused by conformance to Laser Notice No 50 dated June 24 2007 Operating temperature and humidity 0 to 50 C lt 80 non condensing 15 Some models do not support power meter See next page 16 If option 004 005 or 007 is ordered the standard integrated power meter is not available 17 CW 25 C 18 CW 10 to 50 C 41 C difference between max min values over 1 minute SM fiber 2 m 19 Modulation 1 5 with 10 minute warm up 20 CW input 20 dBm at 1550 nm 23 C 2 Using Master FC connector 21 Peak power subtract 3 dB for modulated tones 22 60 to 3 dBm Option 007 850 nm 23 CW model 007 At 10 dBm 1310 nm 1550 nm At 10 dBm 850 nm 25 C model 004 005 At 0 dBm 1310 nm and 1550 nm Using Master FC connector After zero offset 24 Safety measures for laser products This option complies with optical safety standards in IEC 60825 1 21CFR1040 10 and 1040 11 the following descriptive labels are affixed to the product THIS PRODUCT COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO 50 DATED JUNE 24 2007 Product Brochure MT9083 Series 11 Standard Light Source and Power Meter Built in LS MT9083A2 B2 C2 standard built in
15. SMF MMF Optical Power Meter Retrofit MT9083A2 B2 C2 104 SMF Optical Power Meter Retrofit MT9083A2 B2 C2 105 SMF High Power Optical Power Meter Retrofit Replacement Adapters Type OTDR and Power Meters Power Meter Power Meter MT9083A2 B2 C2 004 MT9083A2 B2 C2 005 only MT9083A2 B2 C2 007 only FC J0617B MA9005B 37 LP FC Angled FC AFC J0739A MA9005B 37 LP FC ST J0618D MA9005B 38 LP ST DIN J0618E MA9005B 39 LP DIN HMS 10A J0618F MA9005B 43 N A SC UPC or APC J0619B MA9005B 40 LP SC Anritsu Soft Carrying Case B0582A Fiber Microscope f wll o Anritsu J1530A to J1535A Plug in Converter The photo shows the J1534A Video Inspection Probe OPTION 545VIP G0306A Video Inspection Probe x 400 Hard Carrying Case B0549 Product Brochure MT9083 Series 15 MT9090 Series IA Network Master MU909011A Fault Locator Module Compact fault locator instrument for an easy and accurate verification of drop cable installation MU909014x 15x pOTDR Module Compact OTDR for full automatic verification of optical networks FTTHPON Metro and Core Anfitsu MU909020A OCA Module Compact CWDM channel analyzer to verify power levels drift and channel presence of CWDM networks MU909060A GigE Module Dedicated field test solution for installation and troubleshooting Ethernet links in the access network Specifications ar
16. apan Phone 81 46 296 1221 Fax 81 46 296 1238 e Korea Anritsu Corporation Ltd 5FL 235 Pangyoyeok ro Bundang gu Seongnam si Gyeonggi do 463 400 Korea Phone 82 31 696 7750 Fax 82 31 696 7751 e Australia Anritsu Pty Ltd Unit 21 270 Ferntree Gully Road Notting Hill Victoria 3168 Australia Phone 61 3 9558 81 77 Fax 61 3 9558 8255 e Taiwan Anritsu Company Inc 7F No 316 Sec 1 NeiHu Rd Taipei 114 Taiwan Phone 886 2 8751 1816 Fax 886 2 8751 1817 1404 Catalog No MT9083 Series E A 1 13 00 Printed in Japan 16 OCT 2014 ddcw CDT
17. ct Accessories amp Replacement Items Accessories Must be added as separate chargeable line items Model Order No Description Model Order No Description W3644AE MT9083 Series ACCESS Master Operation Manual CD Z1632A Battery Charger W3634AE MT9083 Operation Manual Hard copy J1530A SC Plug in Converter UPC P APC J W3637AE MT9083 Quick User s Guide Hard copy J1531A SC Plug in Converter APC P UPC J B0582A Soft Carrying Case J1532A FC Plug in Converter UPC P APC J B0583A Hard Transit Case for MT9083 attache style J1533A FC Plug in Converter APC P UPC J B0549 Hard Carry Case for MT9083 with handle and wheels J1534A LC SC Plug in Converter for SM SC P LC J Z0921A Battery Pack for MT9083 J1535A LC SC Plug in Converter for MM SC P LC J Z1625A AC Adapter J1295 Car Plug Cord J0979 A 2 Japan Power Cord J1480A USB Ethernet Converter J0980 A 2 Power Cord for USA Canada Taiwan Connector Video Inspection Probe VIP Option J0981 B4 Power Cord i SAS x 200 x 400 J0982 C7 Power Cord G0306A Connector Video Inspection Probe Lite Option x 400 J0983 S3 Power Cord NETWORKS PC Emulation Software for Data Analysis and Reporting J1027 P4 Power Cord J1028 D1 Power Cord 14 Product Brochure MT9083 Series Retrofit Options for existing units unit must be returned to authorized service center MT9083A2 B2 C2 110 Protector Option Retrofit MT9083A2 B2 C2 107
18. e 7 Single Mode SMF 10 125 um ITU T G 652 MT9083B2 500 1000 2000 4000 10000 20000 ns 46 46 44 dB 46 46 dB 25 25 dB 19 3 10 20 50 100 200 Pulse width 100 ns 25 25 23 dB 10 Pulse width 100 ns Fiber Type Pulse Width Dynamic Range 7 18 is mode 3 40 20 50 100 200 10 125 um 500 1000 2000 4000 0 125 um 10000 20000 ns SMF above SMF MMF 4000 ns MT9083A2 MMF 3 10 20 HYBRID 200 500 1000 850 nm Not support 1000 2000 4000 ns 42 41 dB 42 41 35 dB 42 41 41 dB 40 39 38 dB 42 41 41 40 dB 50 100 2000 42 41 dB 29 28 dB 11 Wavelength Fiber Type Pulse Width Dynamic Range 9 7 13 MT9083A2 073 v 1310 1550 nm 25nm ingle Mode 39 37 5 dB 1310 1550 nm 25 nm 3 10 20 50 100 200 m MT9083A2 055 4645 nm to 1655 nm ida m 500 1000 2000 4000 39 9 37 34 5 dB 10000 20000 MT9083A2 057 v i9 0199071629 nT ITU T G 652 ns 37 35 5 32 5 dB SMF above MMF 3 10 20 50 100 1310 1550 nm 25 nm HYBRID 200 500 1000 2000 39 37 5 d n MT9083A2 063 Y 850 1300 nm 30 nm SMF MMF 4000 ns 850 nm Not support 1000 2000 4000 ns 29 28 dB Deadzone Fresnel e IOR 1 500000 lt 1 m lt 80 cm typ Deadzone Fresnel 8 IOR 1 500000 lt 1 m lt 80 cm typ Deadzone Fresnel 8 IOR 1 500000 lt 1
19. e subject to change without notice e United States Anritsu Company 1155 East Collins Blvd Suite 100 Richardson TX 75081 U S A Toll Free 1 800 267 4878 Phone 1 972 644 1777 Fax 1 972 671 1877 e Canada Anritsu Electronics Ltd 700 Silver Seven Road Suite 120 Kanata Ontario K2V 1C3 Canada Phone 1 613 591 2003 Fax 1 613 591 1006 e Brazil Anritsu Eletronica Ltda Praga Amadeu Amaral 27 1 Andar 01327 010 Bela Vista Sao Paulo SP Brazil Phone 55 11 3283 251 1 Fax 55 11 3288 6940 e Mexico Anritsu Company S A de C V Av Ej rcito Nacional No 579 Piso 9 Col Granada 11520 M xico D F M xico Phone 52 55 1101 2370 Fax 52 55 5254 3147 e United Kingdom Anritsu EMEA Ltd 200 Capability Green Luton Bedfordshire LU1 3LU U K Phone 44 1582 433200 Fax 44 1582 731303 e France Anritsu S A 12 avenue du Qu bec Batiment Iris 1 Silic 612 91140 VILLEBON SUR YVETTE France Phone 33 1 60 92 15 50 Fax 33 1 64 46 10 65 e Germany Anritsu GmbH Nemetschek Haus Konrad Zuse Platz 1 81829 M nchen Germany Phone 49 89 442308 0 Fax 49 89 442308 55 Printed on Recycled Paper e Italy Anritsu S r l Via Elio Vittorini 129 00144 Roma Italy Phone 39 6 509 971 1 Fax 39 6 502 2425 e Sweden Anritsu AB Kistagangen 20B 164 40 KISTA Sweden Phone 46 8 534 707 00 Fax 46 8 534 707 30 e Finland Anritsu AB Teknobulevardi 3 5 Fl
20. ent functions and performance required for optical fiber construction and maintenance in a compact lightweight all in one unit that eliminates the burden of carrying many different test sets and instruments on site Whatever your work construction or maintenance long haul or intra building Anritsu has an MT9083 model for your needs ACCESS Master Key Features Ready to test in about 15 seconds and all day without recharging Specialized testing modes simplify operation High resolution and high dynamic range ensure quick and through fiber evaluation Intelligent analysis software identifies problem splices connectors and even macrobends Rugged sealed design provides years of service in the most challenging environments Large 7 inch enhanced display for easy viewing of results indoors or outdoors Test multiple wavelengths with a single unit single mode multimode or both Unique in service testing without the need for external filters New feature offering easy graphical summary amp PDF reporting Verify connector quality with optional connector inspection microscope Password protection feature for important file on internal memory Full SCPI Command Support for Remote Operation or Automated Testing Multiple Models to Meet Any Testing Requirement e MT9083A2 General purpose enhanced range with full 1 x 64 PON support up to 39 dB MT9083B2 High performance enhanced range with full 1 x 64 PON support up to
21. er base unit Enhanced display for indoor outdoor use 2 Select Optical Configuration Includes choice of OTDR connector adapters select in step 5 below MT9083C2 Series OTDR Ultra high Performance Model Model Order No Wavelength Application MT9083C2 053 1310 1550 nm SM General purpose model for construction maintenance and fault location MT9083C2 057 1310 1550 1625 nm SM General purpose plus enhanced macrobend detection at 1625 nm MT9083B2 Series OTDR High Performance Model Model Order No Wavelength Application MT9083B2 053 1310 1550 nm SM General purpose model for construction maintenance and fault location MT9083B2 055 1310 1550 nm amp 1650 nm SM General purpose models for construction maintenance and fault location plus In service measurement integrated filter to block transmissions MT9083B2 056 1310 1490 1550 nm SM General purpose plus 1490 nm for FTTx PON applications MT9083B2 057 1310 1550 1625 nm SM General purpose plus enhanced macrobend detection at 1625 nm MT9083B2 058 1310 1490 1550 1625 nm SM Full spectrum characterization for CWDM applications MT9083B2 063 850 1300 nm MM 1310 1550 nm SM Best unit for contractors or anyone who installs or maintains hybrid networks MT9083A2 Series OTDR Base Model Model Order No Wavelength Application MT9083A2 073 1310 1550 nm SM General purpose model for construction maintenance and fault location MT9083A2 055 1310 1550 nm amp 1650 nm SM
22. ith up to 128 branches Up to 150 001 Data Points for Increased Accuracy The MT9083 series also collects up to 150 001 with a resolution of just 2 m This provides the necessary detail when installing and maintaining fiber spans Event Table with User Defined Thresholds PASS FAIL thresholds for key acceptance criteria such as splice loss connector loss and reflectance can be set in the MT9083 allowing technicians to easily assess a fiber s condition Failing values are clearly highlighted in the event table alerting technicians of potential problems Solutions for Various Measurement Needs Products that offer many features are often complicated to use The ACCESS Master however simplifies operation by offering task specific testing modes that automate testing and guide novice users Dedicated testing modes are available for fault location cable installation loss budget testing and visual fault location Fiber Visualizer Fiber Visualizer is a new fault location function designed to simplify the entire testing process Fiber Visualizer automatically selects the testing parameters to ensure the correct setup and provides a simple graphical summary of the fiber under test within seconds A comprehensive PDF report can then be customized and generated completing the testing process In addition these files can be opened on PDF viewer AVG 30 Sec m 310086 km Events 4 d8 Refiect dB dB km 4490 0
23. ll optical ports with that connector type or customer can select different adapters by specifying the adapter for each of the three optical ports see examples below Optical Connectors One adapter type is provided for each port at no charge must be added as separate line items NOTE FC APC and SC APC are not available for MM OTDR or Optical Power Meter Model Order No Description Model Order No Description MT9083A2 B2 C2 025 FC APC Connector single mode OTDR only additional charge applies SC APC Connector single mode OTDR only additional charge applies MT9083A2 B2 C2 037 FC Connector MT9083A2 B2 C2 040 SC Connector Note UPC and APC connectors are not compatible the internal optics are different and must be specified at time or order MT9083A2 B2 C2 038 ST Connector MT9083A2 B2 C2 026 MT9083A2 B2 C2 039 DIN Connector UPC Ultra Physical Contact APC Angled Physical Contact Examples 1 MT9083B2 053 with MT9083B2 004 Power Meter option Customer can specify MT9083B2 040 for the SM OTDR port and MT9083B2 037 for the OPM port at no charge 2 MT9083A2 063 with MT9083A2 007 Power Meter option Customer can specify MT9083A2 040 for the SM OTDR port MT9083A2 037 for the MM OTDR port and MT9083A 037 for the OPM port at no charge 3 MT9083C2 053 with no options Customer can specify MT9083C2 026 for the SM OTDR port however an additional charge applies 6 Sele
24. loss ORL Averaging modes Timed 1 to 3600 sec Live Fiber detect Verifies presence of communication light in optical fiber Connection check Automatic check of OTDR to FUT connection quality Trace overlay and comparison Template function USB keyboard support Remote control Video output to PC Password protection feature Operating temperature and humidity 10 to 50 C 8096 non condensing Storage temperature and humidity 20 to 60 C 8096 non condensing Vibration Conforming to MIL T 28800E Class 3 Dust proof MIL T 28800E Dust Exposure Class 2 Drip proof IP51 IEC 60529 JIS C 0920 TYPE I EN61326 1 EN61000 3 2 EN61010 1 1 Typical backlight off sweeping halted at 25 C 6 hours typical continuous testing 2 Either high density value is selected depending on distance range 3 Resolution Low Density Product Brochure MT9083 Series 9 e OTDR Specifications HR ER Options Mode 4 MT9083C2 053 Wavelength 1310 1550 nm 25 nm MT9083C2 057 HR ER Mode MT9083B2 053 A Options 1310 1550 1625 nm 25 nm Wavelength 1310 1550 nm 25 nm MT9083B2 055 V 1310 1550 nm 25 nm 1650 nm 5 nm MT9083B2 056 Y MT9083B2 057 v MT9083B2 058 v MT9083B2 063 HR ER Options Mode 4 1310 1490 1550 nm 25 nm 1310 1550 1625 nm 25 nm 1310 1490 1550 1625 nm 25 nm 1310 1550 nm 25 nm 850 1300 nm 30 nm MT9083C2 Fiber Type Pulse Width Dynamic Rang
25. m boots Users will not be able to use the system until the password is authenticated This feature is useful if you want to limit the use of your measuring instruments to designated users or you want to protect important files on the system s on internal memory o ocn MS be Press the Up Down keys to move cursor press Enter to change the value Fig 10 Password Setting 8 Product Brochure MT9083 Series Data Table for Saved Results Loss test set measurements for multiple wavelengths can be saved into a results table for easy comparison and archiving The table can also be saved as a text file and exported to a PC spread sheet program for further manipulation or integration into a standard company template Video Inspection Probe Support When equipped with the optional connector video inspection probe VIP the MT9083 becomes a powerful tool for evaluating connector cleanliness and quality Connector end faces can be safely viewed and images stored to document all aspects of your network We have added a Pass Fail analysis function to the conventional VIP This new function inspects the state of the connector end using video It can automatically inspect the end of the optical connector for defects and scratches The automatic pass fail determination is made in accordance with the IEC61300 3 35 standard You can also create a PDF report on the MT9083 series Press START for Live image Fig 11 VIP Mode
26. ompact Light Weight and All in one With its versatile built in functions the ACCESS Master offers the ideal solution for efficient optical fiber construction and maintenance The MT9083 delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly small and lightweight package At only 28 4 cm wide x 20 cm tall x 7 7 cm deep and 2 6 kg 5 7 lbs it is field portable yet rugged enough to withstand the outside plant environment When equipped with power meter and visual light source options it replaces several larger pieces of test equipment Up to 10 hours battery life plus quick recharge Optical Power meter options with up to 30 dBm measurement range G Visible laser source for easy fiber identification and bend break location Up to three wavelengths from a single port for any application G Dual USB ports for easy data transfer and connector inspection microscope 9 Dedicated short cut keys to quickly move between events or view trace fill screen Numeric keypad with dedicated keys for easy operation Dedicated function keys for selecting parameters Rotary dial for precision cursor movement Arrow keys for quick zooming and navigation through menus START key for simple one button testing D 7 inch indoor outdoor color TFT LCD display with LED backlight Product Brochure MT9083 Series 5 Exceptional OTDR Performance from the World s Fir
27. rts the universal Telcordia SR 4731 issue 2 format making it compatible with not only legacy Anritsu and NetTest products but with many other vendors data Free and Simple Software Upgrades Firmware upgrades are easily performed via USB and available from the Anritsu website for registered users or through Anritsu customer support Active Fiber Check Not only can OTDR measurements be affected when the optical fiber is in service but there is a potential risk of damage to the transmitter and OTDR receiver To prevent these problems the MT9083 verifies if light is present before starting measurement and will not transmit if it is An on screen warning and internal OTDR protection are also part of this useful feature Integrated Macrobend Detection With many technicians making the switch from copper installations to optical fiber installation issues such as macrobends are bound to occur To help prevent this Anritsu has developed a macrobend detection feature for the MT9083 that will alert technicians when a possible macrobend is present This provides a higher quality of service for the customer and eliminates costly troubleshooting for you Multiple Wavelengths and Models Whether you need singlemode and multimode testing capabilities in one unit or standard 1310 nm amp 1550 nm installation wavelengths plus 1650 nm with a filter for maintenance testing The ACCESS Master can be configured to meet your individual needs C
28. ssing files Value Whatever your construction or maintenance needs the new ACCESS Master MT9083 is designed to reduce the time to install commission and maintain your optical networks without breaking your budget NETWORKS PC Software for Analysis and Reporting Once the data is collected NetWorks PC emulation software makes analysis and report generation a breeze Professional reports including splice loss fiber acceptance and exceptions as well as various printing options are possible with only a few mouse clicks Template Feature To simplify fiber acceptance the Access Master incorporates an on the fly template feature to quickly locate and measure all splices in a fiber cable In addition an on screen highlight blocks out the expected splice locations during trace acquisition Remote Command Support To simplify and automate testing in manufacturing and lab environments the MT9083 supports SCPI commands Through the use of a USB converter and a common scripting program such as LabView the MT9083 can be quickly integrated and immediately reduce testing times Remote control can also be used for remote unmanned monitoring applications Product Brochure MT9083 Series A True All in One Tester An OTDR Optical Power Meter and Visible Light Source are built into Anritsu s compact light weight MT9083 supporting tasks ranging from searching for faults in optical fibers to QoS evaluation to FTTx troubleshooting
29. st OTDR Manufacturer Evaluation of access networks ranging from a few kilometers to metro networks reaching up to 100 km in length is becoming commonplace requiring OTDRs to have the performance and functions for evaluating both short and long fibers Designed with this in mind the ACCESS Master delivers on both fronts Improved Short Fiber Analysis An event dead zone of less than 1 m 80 cm typical and a sampling resolution of 5 centimeters allow the MT9083 to evaluate connections and troubleshoot central office FTTx and intra building faults with ease providing a level of detail never before seen OTDR Standard Anritsu_3ns SOR dg Horiz Shift 0 0004 km Vert Shift 9 750 dB 0 07 2012 Aug 13 20 36 WL 1310nmsm DR 4km PW 3ns HR i 0 0001km 0 0037 km 0 276 0 0036 km Sen ee Fig 3 With its high resolution optics the MT9083 provides exceptional detail allowing users to quickly determine where the problem is even when events are closely spaced Extended Range Testing of 200 km Fibers In addition to its superb high resolution performance the MT9083 also features up to 46 dB of dynamic range allowing it to easily test 200 km spans making it a very useful tool for any network type Fig 4 Spans of over 200 km are also easily tested making the MT9083 the only tool you will need for any network type Full PON Testing Many OTDRSs claim to be able to test PONs but being able to do it
30. stabilized Light Source Battery Pack Z0921A OPM MT9083A2 B2 C2 standard built in Optical Power Meter Lithium lon secondary battery Options Optical Port Voltage Capacity 11 1 V 4200 mAh MT9083B2 C2 053 1310 1550 nm SM 53 W x 19 H x 215 D mm 330 g typ MT9083A2 073 1310 1550 nm SM Tv Iw Charging 5 to 30 C lt 80 RH 1310 1550 nm SM Discharging 20 to 60 C lt 80 RH ee 1650 nm SM Storage 20 to 50 C lt 80 RH EN Environmental Conditions lt MT9083B2 056 1310 1490 1550 nm SM fo ov Y MT9083A2 B2 C2 057 1310 1550 1625 nm SM Pov Y MT9083B2 058 1310 1490 1550 1625 nm SM v v AC Adapter Z1625A ik SS Rated AC Input 100 V ac to 240 V ac 50 Hz 60 Hz v Rated DC Output 12 V dc 5A 47 W x 33 H x 112 D mm 240 g 850 1300 nm MM 1310 1550 nm SM MT9083A2 B2 063 S Environmental Operating 0 to 45 C 20 to 80 R H Conditions Storage 20 to 70 C 10 to 90 R H 12 Product Brochure MT9083 Series Ordering Information Please specify the model order number name and quantity when ordering The names listed in the chart below are Order Names The actual name of the item may differ from the Order Name 1 Specify Base Unit Includes ACCESS Master OTDR AC charger adapter line cord battery pack 1 printed quick user s guide and user s manual CD Model Order No Description MT9083A2 B2 C2 ACCESS Mast
31. with both high resolution and high range is what sets the MT9083 series apart Splitters up to a single 1 x 128 or closely spaced cascaded splitters are completely and accurately measured with industry leading resolution Fig 5 The MT9083 series provides high range and excellent resolution of PON systems Waveform Comparison Function Compare current and stored trace data to easily assess changes over time and to locate problems before they affect service or compare traces at different wavelengths to identify installation issues such as macrobending Standard High Resolution Display The MT9083 series now features a standard 7 high resolution display with excellent readability both indoors and outdoors even in direct sunlight O Product Brochure MT9083 Series Dual mode High Resolution Enhanced Range Operation While many OTDRs provide good deadzone resolution or high dynamic range the MT9083 series features a dual mode design that allows a single unit to excel in both categories The user can simply select HIGH RESOLUTION HR mode or ENHANCED RANGE ER based on the current task at hand When HR mode is selected this mode provides good measurement range with an industry leading deadzone 1 m When ER mode is selected it provides unparalleled performance for measurement distance measurement speed and deadzone allowing a 100 km fiber to be tested in less than 10 seconds ER mode is also used for testing PON networks w

Download Pdf Manuals

image

Related Search

Related Contents

UNIFLAIR Manuale di istruzioni Instruction manual - mark-off  カタログ(約3027KB)  Philips BT2110  pdf alga limpia peel off  KOMPAKT REGO C5 - Manuel - Mars 2015.indd  1794-6.5.5, DeviceNet Adapter Module User Manual  AG-Coop Mode d`emploi - Fédération nationale des sociétés  8 Août 2015 - L`Abeille des Deux  M60/70C  MDO3000 Series Mixed Domain Oscilloscopes User Manual  