Outdoor Station DPC-53x

image

Contents

1. When test you need to input the monitor range please press to process test During the batch testing LCM outdoor station can list all monitors thereinto reverse video means the monitors passed testing normal display means failed testing LED outdoor station only display the normal online monitors Simulation call process operates all practical call signal but the being tested monitors will be in silent The monitors will display 3 seconds image during testing and shut down automatically after testing It will cost 5 seconds to test one monitor 2 Debugging instruction 1 Enter into debugging status please press button screen displays please input password then input the special startup serial number for example to enter into the corresponding debugging items The screen will show reverse video activated icon 2 Can enter into the multi debugging items at the same time For example if you already enter into 9001 time according to 1 step to regulate the volume of outdoor station you can enter into other debugging items at the same 3 If you already enter into certain debugging item press again then input startup serial number of deserved debugging item to quit 4 When outdoor station is under standby condition press button screen displays please input password then input 9008 screen displays please input password Then input 8 digit correct system passwor
2. How to enter into and quit debugging mode SN Steps Explanation 1 L gt 9004 gt debug passworll Enter into debugging mode without starting any option 2 L gt 900 gt debug passwort Enter into debugging mode and start 9002 option 3 L gt 9009 Quit debugging mode and return to normal status The waiting hint under the debugging mode is debugging mode operations in this mode are as follow 1 Basic debugging function list SN Option and operation Function and simple operation explanation Adjust outdoor Use to adjust the outdoor station s volume Hardware of station higher than version 4 0 is necessary When outdoor station s volume is small or with noise you can adjust the 1 station s Volume volume to solve this problem gt po0 Outdoor station answer channel press 1 to rise press 4 to low Outdoor station calling channel press 3 to rise press 6 to low 2 Call and answer ti gt 9002 Use to simple debugging and realize single debugging and also use to look up monitor number Press call button to send message of calling guard center outdoor station will show the monitor s number and chime the hint sound after receives it Outdoor station will call this monitor 3 seconds later after shows the calling information and monitor address which can substitute the handiwork calli
3. floor and connect the monitors apartment by apartment It is easy to handle if you separate big area to small area b For network system please debug each single building and then debug the network c For inner intercom system basically when system and each monitors work normally you can just make the spot test of the intercom d For the alarm system debugging please see alarm system debugging instruction for reference e During the debugging period it is very important to find out failure reason correctly please see Judge and solve the familiar problem for reference f Fully understand the debugging function simplify the debugging method and judge the failure area quickly The explanation of the user password mode If under un public password mode namely the user password mode the operation step to enter into system parameter setup is as follow when outdoor station is under standby condition press button outdoor station shows Please input room number and there is a lock icon on top right corner Then input 0 0 0 0 outdoor station shows Please input password prompt to input the item be set necessarily After input outdoor station shows please input password to prompt to input the system password The other remaining operation is the same as public password If you want to return to the public password mode please see item 4 on outdoor station management parameter
4. h Under standby state input correct room number and system will call corresponding room automatically For example the second floor and room 1 please input 0201 The twelfth floor and room 8 please input 1208 Press fo clear wrong number and input correct room number again Press o Ha to call the room which is called last time Outdoor station has a DI bell when it is connected with room If the indoor monitor do not hang up or do not have this number it will be shown no the screen and can not connect When connect room and the user does not pick up the handset display calling process and ring DI bell The indoor monitors which are called can display visitor image clearly and can communicate with the visitor after pick up the handset And the same time outdoor station show duration of communication until hang up the handset or press on outdoor station to clear Press button to open the electronic lock Please come in was shown on outdoor station and it means the door is unlocked The communication time 90 seconds if overtime the system will shut off communication automatically and outdoor station return to standby condition 2 Under common password mode unlock by password a When outdoor station is under standby condition press button and outdoor station shows Please input password remind to input password to unlock the door b Input 4 digital number unlock password c If the password is corr
5. lock in this block Outdoor station can call and talk guard center and transmit images to guard center at the same time In video frequency network and also can require guard center to unlock or provide other services Input correct password to unlock electronic lock Can set two passwords to unlock door and can change password conveniently and termly Can unlock by using IC card 2 Main feature and electronic parameter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Power supply DC 15 18V Static current 100mA Working current 500mA Environment temperature 10 50 C Camera cell 380TV lines 1 3 inch CCD camera Camera lens F 2 focus by hand 78 degree horizontal visual angle 0 1 Lux Night vision Infrared six IR LED Video signal CCIR standard 1 Vp p range 75Q impedance Card type IC card or ID card Card capacity 500 sheets Method of adding card operate by outdoor station keyboard or by computer Keeping data times 10 years Not lose data when power is broken off Window of reading card Share with display screen Audio output power 0 8W can adjust volume Audio frequency response 300 3 400Hz Audio transmit among line full duplex Network cable type RS 485 card function do not need to be set extra cable Network cable distance 2 kilometers use twisted pair shielded cable Mounting 4 Operation Instruction 1 Call Units a b c d e g
6. 13 15V which is normally the voltage for electron magnetic lock gt SW3 Power output switcher if switch to off the P and P will no voltage output gt PTRI1 To change the output voltage of P and P 14 20 V gt VRI To change the output voltage of L and L when the SW1 is set to off 13 15V gt LK TEST Lock signal test button press this button will generate a unlock signal lt LED indicators gt UNLOCK yellow Lighten up when unlock signal sent in gt DC OUT green Lighten up when P and P have output voltage gt AC IN red Lighten up when there is AC input 3 Trouble Shooting Malfunction A Eliminate Phenomenon Malfunction analysis Remark Cases methods The AC IN LED is off check the AC electricity by the multimeter Deal with the No 220V AC j and check the connection and the AC supply connecters ACE ited The AC IN LED is off exam the pa es fuse by the multimeter to check Change the fuse own whether its open transformer The AC IN LED is off AC fuse is No output AC transformer j f Change the must be the intact 220V input is okay but the damaged transformer same transformer no output a specification The SW3i The AC IN LED is on but the Tu th rn on the A i a DC OUT LED is off Check if the eae m ee SW3 is turned off Output over Disconnect the output load and ed DE Check the load load or short check the P P the output return i
7. AE circuit circuit to normal Overload or the DC OUT is dim out and return Check the load shorted to normal after disconnect the load circuit The VR1 set to Adjust the VR1 and then exam the Adjust the Low output low output voltage output to 18V VRI Change the Adjust the VR1 but nothing change 7 maladjustment VRI Turn the SW3 on and off SW3 connection tan bad h d Change the connection badness happene badness PP SWw3 sometimes Auto jump Overloaded or load partial shorted Check the out Load over flow or connect too many Indoor wiring or add Monitors other PS2 Battery charge Charge voltage is higher than the Change the failure battery voltage but can not charge battery Bu ide ed I the Retouch the attery voltage is norma u Battery switch port connection 7 p n failure connect port are oxidative connect port badness Battery charging port no output or F1self resume Change the battery damage fuse melt down for fuse melt down battery protection Charging circuit Charging port without voltage or Change the badness voltage low power supply Charge failure Charging voltage okay all connect Change the Battery badness ports are normal battery
8. TEM POWER SUPPLY PS2 TECHNICAL INSTRUCTIONS CONTENTS k INTRODUCTION iss sesse ss sees Ee die GE ed 2 2 CONNECTION PARTS AND FUNCTIONG 3 3 TROUBLE SHOOTING wis ass side eed be ie se eed ek Se bede we 3 1 Introduction The PS2 power supply is use to support the whole video audio intercom system It can supply the power to the Door Station Distributor and Indoor Monitor at the same time One PS2 can support one Door Station together with 10 Indoor Monitors if only power the Indoor Monitors it can support 16 pcs Indoor monitors lt Install precaution The PS2 usually install on the first floor near the Outdoor Station and the distance from ground should be over 2 meters gt Do not install the PS2 on the position with rain or high humidity gt Make sure fix the box firmly enough on the wall gt Pay attention to the isolation when connect the AC electricity gt Install the box first then place the storage battery do not use the battery with very low voltage gt Usually the distance between PS2 and Door Station should within 10 meters gt Do not use the old and new or different brand storage battery together lt Electronic parameters gt Output voltage DC 18 0V can be adjusted from 14 20V gt Output currency DC 2 50A gt Standby battery 18V maintenance free lead acid pile standard 3 6V in series gt Self protect circuit short circuit over flow self resume pil
9. Video intercom system Outdoor Station DPC 53x User s MANUAL Contents 1 Introduction of the system and parts 0c eee ce cence cence eee eens 1 2 Main feature and electronic parameter ccc cece cece scence nee Re ene ee ek ee 1 3 Sketch installation dimension and notices of installation ee ee ee ee ee 2 4 Operation Instruction erasers Sint gaat ea ae ew ae ec ee ee Me 3 5 Open door by IC ID card DEERE ED ER Ee GE N EE ee 6 6 Methods of set outdoor station parameter sesse se sesse see se se ee Ee ke ee ee 6 7 System parameter setup of outdoor station esse see sees see see see Re ee ee se ee 8 8 Management parameter setup of outdoor staON esse see see see eee ke se 9 9 Equipment parameter setup of outdoor staOn see ses sees se eee eee cence eee 10 10 Access parameter setup of outdoor staOn see see see see see ee eee eee ee RR ee 12 11 Card management ds eo ee DO ee 2 12 12 Programming room number online 60s eee ese AE sacs HEESE RR Se ER Bee 13 13 Process instruction of system debugging iis GEES RS DEE EK da eines SEG DEE de eed 14 1 Introduction of System and Parts Outdoor station is public parts of intercom systems at entrance or exit of buildings The main features are as below 1 2 3 4 Outdoor station can call and talk with all indoor monitors in this block Outdoor station can accept the command of indoor monitor and unlock the electronic
10. ailed outdoor station will return after shows X If outdoor station shows number repeated which means this number is already in system please input the correct room number over again Important hint 1 The valid programming time is 10 seconds the outdoor station will not be inputted anything and return the standby condition if exceed valid time 2 Please don t program the monitors at the same or they may be programmed the same number 13 Process instruction of system debugging 1 The debugging person should have the following knowledge a Be familiar with the project of the debugging the configuration of the system and the installation of the equipments b Be familiar with the system operation elements and have a clear concept about the purpose and the signal which is transferred by cables of the system c Be familiar with all equipment s function operation elements and the configuration method of system d Be familiar with the setup method option and operation of the system 2 Preparation work before debugging e Check if all the parts are installed correctly f Electrify the system after check wire connection is correct and no short circuit g After electrifying check if the power guide light works normally whether the outdoor station starts to work Cut off the electricity when abnormal situation occurs 3 Some important concept on debugging a For single building system please connect the distributor floor by
11. d to enter into debugging status screen displays debugging mode and the local call receive function is activated 5 Enter into the debugging mode press butfon display shows please input password then input 900 P to quit kystem debugging status and return to standby condition 6 Debugging instruction A When startup show alarm data outdoor station will show the operation status of integrated alarm monitors a Set alarm show set alarm and room number b Cancel show cancel alarm and room number c Alarm of defense area show defense area X and room number X is the defense area number B Startup search online monitors if the start room number and end room number are same it means only search this monitor After startup outdoor station shows the search range first The search will be started automatically after input 7 Under debugging status press sbo1l 8002 8003 8004 8005 8006 8007 to enter into parameter setup or check directly or enter into other option setup etc without input password When finish the parameter operation press to return to debugging status YI y outdoor station Connect with electromagnetic lock Connect with electronic lock Remarks Remarks P DC 18V V1 RVV2X1 Omm P GND V2 RVVP3X0 5mm MV VD Video V3 SYV75 3 AU A1 MA1 Audio H1SRVVP6XO 3mm D1 MD1 Data go up D2 MD2 Data go down L LOCK Pe e 19 SYS
12. e under voltage protection 2 The Connection ports and functions E magnetic lock unpower to unlock type ML ML of door station P P of the door E lock power to unlock type station or distributor L L L L ML ML p P UNLOCK AC IN 18V OUT DC OUT 13715V OUT 287 mm O x O x QO Z O 247 mm lt Connect ports gt P P Main power output 18V 2 5A connect to the Outdoor Station Distributor and Indoor Monitors The output voltage can be changed by using the PTR1 gt ML ML Unlock signal input connect to the ML ML of the Outdoor Station gt L L left Unlock signal output connect to the electronic lock Note that this port is no power in standby it should connect to the Power to Unlock type lock Normally is the electronic lock gt L L right Unlock signal output connect to the electron magnetic lock Note that this port is 13 15V in standby it should connect to the Unpower to Unlock type lock normally is the electron magnetic lock gt BAT BAT Connect to the battery pile Please mind the polarity lt Switchers gt SW1 Use for lock type select if switch to on the L and L signal output will be 18V which is normally the voltage for electronic lock if switch to off the L and L signal output will be
13. ect outdoor station show Please come in and it means unlocked d If the password is wrong outdoor station show Wrong password and unlock failed e If input wrong password three times in 100 seconds the system will forbid unlocking by password 100 seconds Unlocking by password again it will show Cancel unlocking by password After 100 seconds you can continue to use unlocking by password function 3 Under user password mode unlock by password Please refer to the section of administration parameter setting to know how to choose common password mode default and user password mode a b c d When outdoor station is under standby condition press button and show Please input room number and show lock icon on top right corner remind you input room number to unlock Input correct room number and then show Please input password remind to input user password If the password is right Please come in was shown on outdoor station It means the lock is unlocked If the password is wrong Wrong password was shown on outdoor station and refuses to unlock User can update the password 4 digital number operation process as below 1 When outdoor station is under standby condition press button and show Please input room number and show lock icon on top right corner remind you input room number 2 Input correct room number and will show Please input password then press and will show Please input original pass
14. ess users should setup the number according to situation The setup range is from 0 to 2 setup 0 for connecting one indoor monitor About room number setup method please see appendix of this chapter for reference This parameter is to choose whether the system is double channel system which means the guard center and outdoor station can call the indoor monitors at the same time Setup 1 for the double channel setup 0 for single channel Please see appendix of Part B for reference 10 To check whether the door opens for long time When setup 1 if the door opens more than 1 minute outdoor station will send hint sound and inform guard center 8005 06 DOOR ALARM When setup 0 the above function is forbidden Remark This function need to be equipped with the door magnistor 8005 07 SPEAK HINT reserved Select the feed back ring tones when calling the 8005 07 TONE SELECT monitors Remark The equipment parameter setup only fit for the outdoor station with V7 0 or above software version the previous outdoor station doesn t support this setup 10 Access parameter setup of outdoor station Setup the access control function 0 means no access control f According to function 1 means ID card outdoor station with access control 8006 01 ACCESS the access function 2 means IC card outdoor station with access control control function function This parameter is for setup the access controller s time and da
15. f Above operation base on outdoor stations are network type If not it is no use when press 0000 and show Not network type return to standby condition 5 6 Open door by IC ID card not support all types 1 Put card near display window 2 5CM the distance is different from IC and ID card when outdoor station under standby condition If your card is authorized to open this door outdoor station will show com in Please remind the electronic lock is unlocked 2 If your card is not authorized or authorization is overdue outdoor station will show Invalid Card remind this card can not unlock the door How to set outdoor station parameter There are too many contents during setting outdoor station so please read this manual carefully before any setup for this system to avoid any mistakes 1 Setup content of outdoor station including types as below a b c d e System parameter setup For Debugging engineer only including the type of system configure running parameter and so on Management parameter setup Manager take charge of setup and amend including unlock password and other items Equipment parameter setup For Debugging engineer only including the number of extension indoor monitors the channels of outdoor station chosen and so on Access parameter setup For Debugging engineer only including address of access network clock setup and so on Card management setup manager take charge of set
16. g massage will be to guard 8002 03 0 WARN center automatically And the password unlock function will be forbidden automatically 3 minutes 8002 04 CODE MODE reserved 0 reserved 8002 05 ROOM RANGE 0 8002 06 CODE QUERY reserved 8002 07 DISPLAY MODE reserved 0 To change outdoor station s management password When operating it will display original management 8002 08 password then just input 8 digital new password 88888888 ADMIN CODE directly 9 Equipment parameter setup of outdoor station 8005 01 8005 02 8005 03 8005 04 8005 05 PHONE RANGE LOG TRANSMIT MON TALKING EXT PHONE DUAL CHANNEL This parameter is for testing function of the IDS800 if the extension address is out of the range it can t be tested by the software The setup format is AABB CCDD you need to input the full four digital room number thereinto AABB is the minimum room number CCDD is the maximum room number This parameter is used for IDS800 to record the facilities working information If setup 1 outdoor station will upload the calling unlocking status if setup 0 outdoor station won t upload the information If set up 1 the indoor monitor will show the picture and directly call with outdoor station if set up 0 the indoor monitor won t show the picture and call with outdoor station If users connect more than one indoor monitors the same calling addr
17. he number of this system address is memorized inner the extension and the extension s location in the system has nothing to do with the address information will not lose if the power shut up How to enter into waiting program status When system is under debugging mode press gt 8003 to enter into waiting program mode Instruction of waiting program status It is shown Please press call button under waiting program status Under waiting program status system will quit automatically if no operation in 30 seconds or press to quit immediately Process of program operation According to above hint outdoor station enters into waiting program status Press call button of the being programmed monitor then outdoor station shows the original number of the being programmed monitor if this monitor is not programmed or change the inner memorizer the outdoor station will show ____ if the original number of this monitor can not be decoded the outdoor station will show then show new room num ber prompt to input the new S number Input new monitor number if input wrong press to cancel and then input number over again After input new room number press to start program The outdoor station show programing now which means the system is programming the monitor number The programming will cost 3 4 seconds If it is successful the outdoor station will return to being programmed status after shows kd If the programming is f
18. ng Alarm parameter This option is used to debug the alarm system and decompose the alarm function in the cell level Startup this option alarm information will be not sent to the guard center 3 display but displays on the outdoor station immediately with hint sound the displa 9004 j A TET y 29 9 2 format is monitor number alarm information set alarm information Usually startup this function then debug it in the running outdoor station Network calls to assistant debugging system and the intercom debugging Communication parameter After startup this option the data of network call and intercom will be 4 display shown on the outdoor station screen automatically namely system cell network bus s relative data will be shown to the debugging person in order gt 9004 l ee to find out problem easily Extension debugging function list Option Name n SN Function and simple operation explanation and operation Function Automatically search the certain range or monitor which is for Search online F checking the information of the online monitor 1 monitor el 901 After startup this operation the outdoor station search and display the gt f present online monitor according to the setup range automatically Function Display the equipment information of the appointed monitor in order to check the monitor information Enter into pr
19. nter into equipment parameter setup Enter into access parameter setup press and show Please input password input and show Please input password after input correct 8 digit debugging password show Access parameter and enter into access parameter setup Enter into card management setup press and show Please input password input and show Please input password after input correct 8 digit management password show Card management and enter into card management setup Remarks The priority of debugging password is higher than management password IManagement password can be replaced by Debugging password b System under debugging condition System work at debugging condition show Debugging mode Please refer to debugging function and option section in this manual Under debugging condition omit process of password input facilitate needed time 4 Special remind on operation Under parameter mode press to turn down pages and choose setup option Input digit number directly to set up Setup successful show Fil Setup failed show DA Press to exit setup System parameter setup of outdoor station Set network address of outdoor station address can not 8001 01 NET ADD be same and address code is 3 bits You can set scale No from 001 to 120 If only one outdoor station set as 0 if more main control 8001 02 MULTI MODE outdoor station should be set as and another ones are 0 set as 2 4 separatel
20. ogram input address of the monitor await to be checked Equipment then press to operate After outdoor station obtains monitor information of information it will display hardware software date of production in three q Monitor lsfooud lines There the hardware information is displayed as monitor address monitor model No in the monitor model code bit 1 is series No bit 2 is the function code 1 standard 2 alarm 3 message 4 full function 5 customize Remark The software should be above version 3 0 otherwise outdoor station can not obtain equipment information and display old version Test monitor s voltage 01 Function can measure monitor s voltage from long distance in order to avoid bothering tenements and using the millimeter There are two numerical values of voltage measurement the wait voltage when screen shuts down and work voltage when screen displays The normal range is wait voltage 15 0 18 5V work voltage 14 0 18 0V usually the test time is less than 1 second Remark Hardware above Version 3 0 is put the bit 10 A D conversion inside to measure the voltage but which below version 3 0 don t have this function Simulation call from monitor 9014 Function Can process to test the simulation call of the appointed monitor or batch monitors in order to test the monitor call function without bothering the tenements
21. te of RTC Press 1 to setup the format is YYYYMMDDHHMM thereinto YYYY is year MM is Present time 8006 04 TIME SET UP month DD is date HH is hour 24h MM is minute In the and date network system the time of access controller is usually Synchronized by software no need to setup by hand CARD 8006 05 reserved This operation will clean up all the registered cards and the 8006 07 ACCESS INIT 66666666 records 11 Card management The access control function of the network can be managed by IDS800 which is an integrated management software Meanwhile outdoor station is also equipped with the card management function The operation process are as follow under standby condition input E gt 8007 gt management password Setup item and Setup instruction 12 Enter the program input the room number and then take the card in front of the outdoor station to add Remark After input room number 8007 01 ADD CARD you can add more cards for same room by repeating above step Enter the program and then take the card in front of the outdoor 8007 02 ERASE CARD i station This operation will delete the card of the appointed room number ERASE BY f 8007 03 Operation method Input the room number outdoor station will show ROOM whether delete press to delete 12 Programming room number online Program room number online namely program online or change extension number indoor monitor address T
22. up including adding card or cancel card can be operated by computer 2 First should find out the password sorts of outdoor station and use occasion a b Debugging password 8 digits which is handled by debugging engineer and used for setup system parameter Management password 8 digits which is handled by manager people when system operate and used for setup management parameter Debugging and management password can be changed Please contact supplier If forget debugging password Default Debugging password is 66666666 and management password is 88888888 Remark Please change password in time to avoid others access system and confuse the system 3 How to enter into setup state a System under standby condition 1 2 3 4 5 Enter into system parameter setup press and show Please input password input 8001 and show Please input password after input correct 8 digit debugging password show System parameter and enter into system parameter setup Enter into management parameter setup press and show Please input password input and show Please input password after input correct 8 digit management password show Management parameter and enter into management parameter setup Enter into equipment parameter setup press and show Please input password input 8005 and show Please input password after input correct 8 digit debugging password show Equipment parameter and e
23. word and remind to input original password When set user password first time original password is set as one group of common unlock password refer to parameter setup 3 Input correct user password and show Please input original password remind to input new user password after finish it show Input new password again Remind to input new user password again And then return to standby condition 4 If operation is wrong or overtime will show Wrong password remind wrong operation and return to standby condition 5 If input wrong password three times in 100 seconds the system will forbid unlocking by password 100 seconds Unlocking by password again it will show Cancel unlocking by password After 100 seconds you can continue to use unlocking by password function 4 Call guard center a Press 0000 when outdoor station is under standby condition and show Calling guard center remind in process of connecting guard center b If guard center is busy or refuse communication system will show System is busy Please call later It means the line is busy and return to standby condition Please call later c If guard center be picked up outdoor station will show communication time limit time is 60 seconds d If over 30 seconds guard center do not pick up outdoor station will shut off calling automatically and return to standby condition e Press to quit calling guard center and return to standby condition
24. y Electric lock should be set as 0 pulse style As to delay 8001 03 E LOCK DELAY 1 time style can set 1 9 seconds to unlock do Set how many indoor monitor can monitor at same time Please set it according to system power supply condition 8001 04 MON NUMBER 2 This function can reduce system power supply quantity and monitor quantity can be 1 5 When guard center outdoor station call indoor monitor 8001 05 NET CALL indoor monitor display or not Set as 0 not display set 1 as 1 display Set as 0 supply power when operate set as 1 supply 8001 06 CAMERA PS 0 power all the time Choose regulation to input room No Set 0 as whole ged ROOM mode should input 4 bits room No Such as 0301 Set 07 1 NO MODE 1 as intelligent mode do not add 0 before room No Such as input 301 is okay Use to change outdoor station system password Will 8001 08 SYSTEM CODE 66666666 show original system password when operate RESTORE Input the password the system will restore to all the 8001 09 66666666 SETTING factory settings 8 Management parameter setup of outdoor station Setup first public Unlock password 4 digital number 8002 01 LOCK CODE 1 This password is also the default password of the 1111 private Unlock mode Setup second public Unlock password 4 digital 8002 02 LOCK CODE 2 2222 number if set to 1 when input the wrong password 3 times CODE ERR within 1 minute a warnin