Home

MAN-Pro Control Inline User Manual-e

image

Contents

1. Select a metal detector number from the i reuzramss20 EN dropdown list 1 j 1 TRAE aG URET gt The product types related to the selected metal detector if any are displayed ee _om lt gt Product Type Adding Product Types oo ae ed From the Product List window click the Line No f Line Name Add New button General Test Settings j Test Setting gt The Product Type window opens Product Type Number Ae ET Select a line number Article Description Type of Product gt The fields are enabled Product Moisture PONP AE TRESI Enter the required product type Product Viscosity information Product Speed Cancel Note The Option tab will only be available T Test avor tina interval Test at moment if one of these test types are selected ing Boers eae Extended Standard Single Test every piece interval pes E 00 00 00 Test when product changes l Test when batch starts Test when batch ends Execute tests manually Cancel a5 36 From the Product Type window click the Store button to save the product type You are prompted to create a new product type If you click Yes follow the same procedures as above Otherwise The Product Type window closes The Product List window refreshes the list showing the new product type Editing Product Types From the Product List window select a product type and cl
2. Repeat as required to add additional products 30 To remove a product from the list Select a product from the list Click the Remove button To save the list of new products Click the Save button gt The products are saved to the database Each product will have the same details as that of the source product Note Only valid products will be saved A notification message is shown if the products can not be saved to the database especially if the product is not compatible to the weigh cell range of the checkweigher Removing Product Types To delete one or more product types Select the product types from the list Click the Remove button gt You are prompted to confirm Click Yes to proceed 31 Changing Tare and Density Values To change the tare value of one ormore products Select one or more product types from the ddd M ae Product List window Edit Remove Right click on the selected product types Show plans ow plans Select Change Tare from the context Plan a batch menu Change Tare O Select Change Density to change the Change Density i density value instead Copy ta weigher Copy to new products gt The Change Tare dialog opens Change Tare Enter the new value New Tare u ae aid Click OK to save the new value OF Cancel Note Use the Ctrl Z keys to Undo the late
3. OT amp BM 3 22 em v Start Listening Slop Lisle tiny Settings Installation List Exit we 3 30PM 76 There are four services that are installed along with SPC Inline Socket Listener Service The SPC Inline Listener Service is respon sible for gathering data from the devices During batch processing it is neces sary that the service is running Data are processed by the service even if the main application is closed By default the service is opened during computer startup For manual configuration the Listener Service Manager is used To open the Listener Service Manager Click the Windows Start button and select Sartorius SPCInline Services Lis tener The icon shows up in the task bar Right click on the icon The shortcut menu appears Start Listening Starts the server socket Stop Listening Stops the server socket Settings Opens the Listener settings dialog Installation List Opens the Installation List dialog Exit Closes the Listener Service Manager application Listener Server Settings IP Address 192 168 0 173 w Listening to Port 60000 Sending Data trom Port BOO Device Downtime Settings Selection criteria for partly empty intervals Checkweigher Protocol keep xml files in this directory C soc_ report LJ To open and use the settings dialog From the shortcut menu select Stop List
4. 4 First page Jump directly to the first page of the report bi Last page Jump directly to the last page of the report Next page Click repeatedly to scroll through the report one page at a time from l lower to higher page numbers Previous page Click repeatedly to scroll 4 through the report one page at a time from l higher to lower page numbers To go directly to a specific page Type the desired page number from the Current Page field 10 of SS Press the Enter key gt The page is opened in the Report Viewer 72 Excel Acrobat PDF File Exporting Please wait Cancel Sove As lea Saver id Desking cr EA My Documents 4 My Somer MyAlecent Sel My Relwork Piroti Ceskhon My Dosumeni wig Mp Computer taira F My Neiwsk Fla pame Statistica 2007 wh a Ce Seve ar bee Eroak Conca You can export the report to other formats such as PDF portable document format and MS Excel Click the Export button gt The dropdown menu opens Select the desired format from the menu gt The Progress dialog opens Wait while the report is being exported gt The Save As dialog opens Enter the file name Click the Save button gt The file is saved to the specified directory 73 To adjust the size of the report page in the Report Viewer Click the Zoom drop down button There are thre
5. Click Yes to proceed Repeat these steps for each item that you wish to delete Printing the Alarm Settings Select an item from the Alarm Settings list Click the Print button gt The Report Viewer opens Click the Print button on the toolbar in the Report Viewer to send the report to the printer Defining Statistics Open the Configuration menu in the main window and select Define Statistics Define Statiatics gt The Define Statistics window opens s Click the checkbox next to each desired Statistics type to activate that type I Hourly M Shift IY Daily Remove checkmarks from statistic types that you do not wish to collect during batch processing Click Ok to save your changes gt You are prompted to confirm Y Are you sure you want to save the changes in the settings Click Yes to save a If you click the Cancel button after having made changes you are prompted to confirm before the window is closed Click Yes to close the Define Statistics window without saving changes 16 Setting Statistics Times Open the Configuration menu in the main window and select Statistics Times gt The Statistics Times window opens Sta of Shit Shit 1 imon per Iia zmn rm Ss eres You can set the start times for the three SS EEAO shifts as desired stop times are set auto Fast ayo wea Monday matically The stop time of Shift 1 is one Ta
6. respectively You can change the settings for violations as well To do this select the desired severity level Inactive Warning or Alarm for each violation on both the Good Production page and the Total Production page N C TUZ Violation C C TU1 Violation Inactive Warning Alarm To restore the default settings for all violations at once Click the Default button Default N Save Pri There are two ways to save settings 7 Click OK to save changes and close this OK N Close Ne window or gt Click the Save button to save changes fault Save Print and keep the window open Editing Alarm Settings To modify an existing alarm setting Select an item from the Alarm Settings list gt This loads the settings stored for the selected item on the Good Production and Total Production pages to the left of the list Modify the settings as desired Click OK or Save to save your changes 14 Delete Default Sa Sartorius AG Alarm Configuration Aiea Mo 111 Machina H Bi fin Cunvelities Maun lt Hamina daly Exceeds Recta fe Tet SO gt Man SO FAN Thagheui Lindeniow A TON wiginiga AA TO wiglalioa chal TN vinlatian EA TU Violation Tatal Production f 1 2 PE ud 100 Sartoriu Deleting Alarm Settings Select an item from the Alarm Settings list Click the Delete button gt You are prompted to confirm
7. Click the Activate button 87 Alternatively you can replace the old license file using the Update License dialog Open the File menu in the main window and select Update License gt You are prompted to confirm Upon activating the new license the system wil be shut down Dio ou Wark io miad Click Yes to proceed Note If any production batches are running the dialog will not open and you cannot update the license at that time gt The Update License dialog opens Note If the license file is invalid an error may occur after which you will not be able to use the program Please contact your administrator or the software manufacturer should this occur 88 Activating the Device License After you obtain the required device Ad licenses see Ordering Product Licenses sd you need to activate each device license individually Checkweighers or metal detec p a tors that do not have active licenses are represented by gray checkweigher or metal detector icons in the Network Configura tion window To activate a device license Open the Network Configuration window See Registering the Devices for more information Right click on a device node in the Net work Nodes tree m SPClnline Server gt A shortcut menu opens Si OOS Oa A Cw eer Select the Activate menu item o E MO SK PESCMSs 9 Add Mew Edit Remove Deactivate Remote i SPClnline Ser
8. Set Password Opens the Password Setting window Log Off Locks the application Update License Opens the license activation dialog Exit Shuts down the application View Menu Monitoring Opens the Production Monitoring window Statistics Opens the Statistics Selection window All Violations Opens the Alarm List window showing both time and tolerance violations Tolerance Violations Opens the Alarm List window showing tolerance violations only Time Violations Opens the Alarm List window showing time violations only Communication Logs Opens the Communication Logs window SPCInline Toolbar Hetyrork Tolerance Configuration Statistics violations Log CHF Bf Aa Bs mse g Belonit aang All Tit Wiolatiors iolatiors Evaluation Menu Automatic Statistics Opens the Auto matic Statistics window Manual Printout Opens the Manual Printout window Graphic Evaluation Opens the Graphic Evaluation window Downtime Report Opens the Downtime Report window Configuration Menu Network Configuration Opens the Network Configuration window Alarm Opens the Alarm Settings window Statistics Definition Opens the Statistics Definition window Statistics Times Opens the Statistics Times window System Settings Opens the System Settings window Language Opens the Set Language window Window Menu Cascade Arranges windows so they overlap T
9. be reprinted or translated in any form or by any means without the prior written permission of Sartorius The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius reserves the right to make changes to the technology features specifications and design of the equipment without notice Status Januar 2012 Sartorius Weighing Technology GmbH Goettingen Germany Printed in Germany on paper that has been bleached without any use of chlorine W_ ProControl Inline 3_0 KT Publication No W626025 e12012
10. sepeceredseDpesserresPesr Communication Logs Click the Tolerance Violations button on the SPCInline toolbar gt The Alarm List window opens IOON le we Ache thud Cy yei be A TUI Vielater 708 208 e433 Ww m m 737 33 3 TU Vielaton AABN 143 111 7 m m Cumdsive Mean lt Nominal NALNE 6184335 1 787 Ese 3m TetS0 gt Max SO 748 205 was m Ww 333 m Tet O gt Max 0 nee eos 11 787 m m Exceed Reyects NANE 6184935 m1 7 m m TUI Vioistion NEE BE m 7 m 3 TetS 0 gt Max SO nese eos m 797 m m Tet 0 gt Max 0 TAR ROS m 7 m m Exceed eects neo 1842 11 7 33 33 TUI Vielstion NAB 184334 mW 737 m m Diamdabve Mean lt Nommal NEA NIS m 7 m wm TetSO gt Max 0 wees 1843 8 mi 737 m m TUI Vielation NALNE 14435 11 737 m 33 TUT Violate RAR NLS m re wm ces Cumulative Mean lt Normal TARA 184d 1 79 m m Tet SO gt Max SO nes 6184335 m1 737 m m Exceeds Regect nec BIS m 7 m 3 TU Violation yee ILN 1 787 m m TU1 Violstion NAVNE 1047M m 7r 333 333 Cumulative Mean lt Normal 70872006 184334 mt 7e7 m m Cumulative Mean lt Nominal NE 184234 m 737 Ere 3 TetS0 gt Max SO yen ON m 707 m m Tet 0 gt Max SO NAUN INU m re m m Exceed Aawct na Ieu 1 737 l K o M 50 Sartorius ProControl lnline File View Evaluation Configuration Window Monitoring Statistics All Violations Tolerance Violations Communication Logs Sartorius ProControl intine File View Evaluation Configuration Window eS Monit
11. a graphic evaluation Click the Print button gt The Graph window opens See Monitoring Production Batches for more information about using the graph window Cancel Print To evaluate data in archived records Activate the Evaluate from archive option in the upper right hand corner of this win dow gt The dropdown list is enabled 63 Select a database name from the list Proceed as described above to print the report To close the window Click Cancel Device Downtime Report Downtime happens when the number of products running through the device drops to zero while the batch is still on going To view the downtime report Open the Evaluation menu in the main window and select Downtime Report gt Downtime Report JE gt The Downtime Report window opens Peedi paa pena Peto paaa fa By default the downtime period is set to Machine tuber i wee a one day starting from the previous day specified in Period From field cect Ba You can edit these values as desired Enter values in all two of the subsequent fields Machine Number Weigher Number Click the Print button gt The Report Viewer opens To close the window Click Cancel 64 Monitoring Data Communications Using the Communication Logs Window To open the window Open the View menu and select Commu nication Logs gt The Com
12. or Click the Statistics button at the bottom of the Alarm List window gt The Statistics window opens See The Statistics Window for more information You can clean up the alarm list by removing data from the violation logs To select more than one item hold down the Control key Ctrl while clicking the desired items Select the item s to be deleted from the list Click the Delete button in the bottom right hand corner of the Alarm List window gt You are prompted to confirm Click Yes to delete 51 if 1 T Vaan Mean Herra thar Horeg Osi S0 iD Ha SD 52 peni peri an ro Be ER ar Fani priar Feni Re i San oe peu ray Fani ei ary TU eto iE GTi iH 14 10 TE eto LETE iiH 1 00 mM tii mI 111 11 mW 111 111 Ej SUELA kdz 100 Sartoriu e Oow p o C e To print the alarm list Click the Print button in the bottom right hand corner of the Alarm List win dow gt The Report Viewer opens Click the Print Report button on the toolbar in the Report Viewer to send the report to the printer To close the Alarm List window Click the OK button in the bottom right hand corner of the window gt The window closes B Sartorius Procontrolointine View Evaluation Configuration Window Monitoring All Violations Tolerance Violations Time Violations Communication Logs r TS Se Using the Statistics Selectio
13. 0 e 4a0 0 67 Exporting Archived Data 70 The Report Viewer 72 Using the Report Viewer 72 Using SPC Inline Services 76 SOCKEE Listener Servite seas oe vaeaacens 76 Automatic Archiving 79 Automatic Statistics Printout 80 Email Notification 44 00 0 lt lt 00 83 Licensing Procedures 85 Ordering Product Licenses 85 Activating the Product 44 23444s 87 Activating the Device License 89 Symbols The following symbols are used in these instructions indicates required steps indicates steps required under certain conditions gt describes what happens after you have performed a particular step indicates an item in a list indicates a hazard Intended Use Sartorius ProControl Inline is designed for monitoring Sartorius checkweighers and metal detectors on production lines SPClInline is a user friendly program that makes it easy to check the connection of devices to the system server monitor data transfer activity and manage the statisti cal data generated for every production batch These instructions describe the use of the SPCInline software Features SPCInline communicates with check weighers and metal detectors over TCP IP The software is installed on an application server and implements bidirectional communication with the networked checkweighers and metal detectors Common Keyboard Shortcuts
14. 16 50 03 02 2006 13 37 03 information i Current data Shows the dates of the earliest and latest samples stored in the main database Number of samples The current number of samples stored in the main database Data on current backup path Shows the dates of the earliest and latest samples stored in the archive database Click OK to close this window To close the backup window Click Cancel in the lower right hand cor ner of the window gt The Backup window closes 69 Exporting Archived Data Delete data from the archive database at regular intervals to keep the use of storage Space at reasonable levels You can purge the database without data loss by export ing data to a different file To open the Export Archive Data window Open the File menu in the main window and select Export Archive Data lt gt Export Archive Data gt The Export Archive Data window opens Expat current data to Database Fie Directory i 5 E E T The Database File Directory field shows a Databate Name default directory for the new database file SPCininedschive20070123 _ Brot To specify a different directory Curent aze of anchre databace 0 MB Click the Browse button represented by an open folder Archive Databases gt The Browse For Folder dialog opens Select a folder from the list 70 Click the Make New Folder button if you wish to create a f
15. This opens the Device Entry window and loads the data on the selected checkweigh Machine Number on er in the input fields Device Number mz s Device Type B EWK ka Seral No BOE 220 746 647 Click OK to save IP Address 192 168 1222 Listening to Port 59001 Sending Data from Port jss000 Cancel k O Edit the fields as desired 21 Checkwergher Settings Machine Humber O01 Device Number maoo Device Type EWK Serial Mo BOE 220 746 647 0 IF Address fs21681 222 w lt Listening to Port 59001 Sending Data from Fort s9000 Add New I Remove Network Nodes SPCinline Serve Ask TestMsq Add New Edt Remove Deactivate Checkweigher Settings Machine Mo 353 Weigher Ho 333 IP Address 192 168 1222 y pe Listening to Fart e000 Sending Data from Fort e0000 Add Hew Edit 2an 22 There is another way to open the Device Entry window Select a device node from the Network Nodes tree gt The Checkweigher Settings box opens with the data from the selected checkweigher Click the Edit button to open the window for editing data gt The Device Entry window opens Deleting Devices Right click on a device node in the Network Nodes tree Select Remove from the shortcut menu gt You are prompted to confirm Click Yes to delete the device information You can do the same in the Checkweigher Settings box Selec
16. a value in the Time field after selecting a period Enter values in all three of the subsequent fields Article Number Machine Number Batch Number Note Wild cards are permitted in these fields An asterisk can be used as a placeholder for any number of characters a question mark stands for a single character You can select from among existing values in the Item Selection dialog To open this dialog Click the Search button next to the Article Number field The Item Selection dialog opens Items listed in this dialog are designated in the following format lt article number gt lt article description gt When the Item Selection window is opened to select a machine or batch the list shows lt machine number gt or lt batch number gt rather than article data 59 Characteristic f Total Production Good Production F Metal Contamination Check For Completeness Report sorted by Article Machine Evaluate from archive Time x 60 Select an item from the list Click Ok The selected item is entered in the Article Number field Follow this procedure to enter machine number and batch number as well Select one or more characteristics to be included in the report Under Report sorted by you can specify whether data in the report is sorted by article or machine Click the Print button The Report Viewer
17. are set to default Repeat until the parameters of all weigh lines are entered 27 Note The Trend Controller tab will appear in the Product Type window if one of the three trend controllers in the checkweigher is activated The same procedures are followed in the Enter parameters for each weigh ine Advanced window Weigh ine no ft x Production Monitoring Average monitoring Operation Mode Serial rejects Operation Mode Editing Product Types From the Product List window select a product type and click the Edit button Or Double click on a product type gt The Product Type window opens contain ing the stored parameter values of the selected product Modify the fields as needed Click the Store button to save the changes gt You are prompted whether to send the file to the checkweigher or not Click Yes to send otherwise click No gt You are prompted to create a new product type 28 2 gt Sartorius ProControtolntine Product List Pe View Evaluation Configuration Window Heb 6 5 d Age eo Select a Checkweigher Weighes Number W333 Produet ID Article Number Article Deseription 1 123 r _ MZ Tune 2 asd New 4 165 5 SA j Remove Change Tare Copy to weigher w Select one or more checkweighers If you click Yes follow the procedures for adding a new product type Otherwise The Product Type window closes Copying
18. of the sender which is the SPC Inline application To add one or more mail recipients Enter the Full Name Enter the valid Email Address Click the Add button The recipient information is added to the list To add more recipients repeat the procedure as required To remove a recipient Select a recipient from the list Click the Remove button The recipient information is removed from the list Click the Save button to save changes Licensing Procedures Ordering Product Licenses The software is shipped with a 30 day license for trial and demonstration purposes This includes one license for the SPC Inline server application and one license for a single checkweigher Sartorius ProCantrolointine Demo A message window opens every time the EEE program is launched indicating that the EPI AE ME ERIR EE TAA software is a demo version The calhe a wll pea n ASA aiita ii After the 30 day demo license expires Shure lemas Y Him ly aerate the program cannot be used again until oa a per you obtain a full version license file actvene Conte e To order a full version license 1 Contact the software manufacturer via phone or e mail Provide them with your company name contact details product ID order codes and installation code Specify the order code s and the number of licenses for each code Valid order codes are 62899XS License per connected EWK or SYNUS checkw
19. opens Click the Print Report button on the toolbar in the Report Viewer to send the report to the printer To evaluate data in archived records Activate the Evaluate from archive option in the upper right hand corner of this window The dropdown list is enabled Select a database name from the list Proceed as described above to print the report Cancel Print lt 2 Manual Printout Jog So by i Evehiate iom aechive B z Piongd Fron 170672000 08912 Peed To 170872000 179823 AtcleMurbee Qi Machine Number 1 a Batch Number q Charactenstic r Sort by Period From Characteristic Total Production Rejected Check Fe Good Production Metal Contamination To close the window Click Cancel Manual Printout To open the Manual Printout window Open the Evaluation menu in the main window and select Manual Printout gt The Manual Printout window opens Select a sorting option from the drop down list in the Sort by field gt The subsequent fields are enabled By default the Period From and Period To fields show the time and date of the first sample and the current time and date respectively You can edit these values as desired For details on entering the desired article machine and batch numbers see Auto matic Statistics Select one or more characteristics to be displayed 61 Chara
20. Close button in the bottom right hand corner of the window 57 Evaluating Statistics Automatic Statistics Automatic statistics is the term applied to data collected automatically during batch processing This data is classified as batch shift hourly daily weekly monthly or yearly statistics To open the Automatic Statistics window Open the Evaluation menu in the main window and select Automatic Statistics E memari Smiri Loa gt The Automatic Statistics window opens susene o pee Before data can be printed you need to define which data the report will contain o Select a type of statistics from the drop Statistics Type eo f are Si down list in the Statistics Type field Yearly statistics Monthly statistics Weekly statistics Daily statistics Petiod Shift statistics 2 Article Number Shift statistics 3 Machine Ninbe Hourly statistics Batch statistics Batch Number Pond m gt The Period field is enabled Select an item from the drop down list in the Period field 58 Time T 00 00 13 59 59 si Evaluate trom archive PCinlineArchive Article Number q MachineNumbe S a Batch Number a Characteristic a m A 5 Item Selection X gt If no value is available for this field a message box informs you of the fact If you have selected hourly statistics Select
21. Keyboard shortcuts are provided for fast access to controls in the user interface such as menu items and buttons Press ALT to view the shortcut character Press the underlined letter or other char acter while holding down the ALT key to activate the corresponding control The following common Windows short cuts are available Esc Closes the active window Enter d Activates the default control if any in the active window F1 Opens the Help window Legal Notices Copyright This documentation may not be duplicated or transmitted for any purpose whatsoever whether in whole or in part without the express written permission of Sartorius This documentation is intended for use by the purchaser only Transfer to third parties whether free of charge or in return for payment is not permitted The software on the enclosed CD ROM is the property of Sartorius The software may not be copied modified reverse engineered or modified through assimila tion The purchaser may operate the soft ware for his her own purposes only and may not permit use of the software by third parties neither free of charge nor in return for payment If you have any problems with the enclosed software please inform the software vendor Sartorius reserves the right to supply updated software with this prod uct No liability is accepted for software installed prior to purchase of this product The purchaser bears liability fo
22. Product Types A product type can be copied from one checkweigher to one or more check weighers Select one or more product types from the list Right click on the selected product types Select Copy to weigher from the context menu The Copy to Weigher dialog opens Check one or more weigher numbers from the list to which the product types are to be copied Click the OK button The dialog closes The selected product types are copied to the selected weigher numbers A product type can be copied to one or more new products Select a product type from the list This will serve as the source copy 29 Right click on the selected product type Select Copy to new products from the context menu Copy to new products SSS The Copy to new products dialog opens LUST AS To add a new product Arae Murta deae PTa Enter the Article Number and the Article Aim me Description Click the Add New button lt n gt The new product is added to the list Add New Remove Note pa No Ea If the texts turn to red this means that the Article Number or the Article Description is the same as that of the source article To add the product to one or more check weighers Atle Decin ETa Select the newly added product from the N Ba list iia O MaD O go siaa On the checkweigher list on the right side check the checkweighers where the product Should be added
23. SE Sartorius User Manual Sartorius ProControl Inline Software Program AA IAT A 98646 002 56 Contents Intended Use 4 Peats on ak ge aul eine eae eee a ee 4 Common Keyboard Shortcuts 4 Legal NotCES oss o 00 9s 6a dic wre es as 4 Launching the Application 5 Starting the Application 5 LOGGING Hl Iso te bs ae od ee eee ws hate 5 The Main Window 6 Setting the Password 8 LOGGING OUl 4 24 4264 a6 65 50ee50 8 Opening the Help Window 9 Customizing Settings 10 System Settings ssecenseeseses 10 Alarm Configuration 13 Editing Alarm Settings 2 22 4 s 44 4 lt 14 Deleting Alarm Settings 15 Printing the Alarm Settings 15 Defining Statistics 16 Setting Statistics Times 17 Setting the Language 18 Registering Devices 19 Adding Devices o2 ea dee Qe ean 19 Editing DEVICES 45d hava ween ams 21 Deleting DeviceS 6 450006404086 22 Retrieving Device Data 23 Pinging DEVICES 6 0 4 o2ent ee eces 24 Managing Product Types Checkweigher 25 Adding Product Types 25 Setting up Parameters fort each Weigh Ne 4 4 ss sa ate g 3 wes 27 Editing Product Types 24 6 2 2 lt 28 Copying Product T
24. VERSION Number of licences per Computer 3 thereof 3 are available valid for 30 day s 8 Licence File ID 67 W9 Licence File Version 2300 8 Licence File Date 10 30 2007 2 48 57 PM Deactivate The list of installation codes is located in the upper right hand corner of the window Four installation codes are listed select either Code 2 or Code 3 Note Licence is valid until 2 8 2007 When submitting the installation code is valid until 2415 2007 be sure to indicate which code it is for example Code 2 DF740095 Sending only the 8 character code in this case DF740095 is not sufficient 86 p the software please activate your copy Howto activate ct ER My Newek Fie Files ol poe rocirdirve be zj Cancel Show License Viewer H Locate valid spcinline lic file C spcinline lic Activate Continue V Activating the Product After you submit the required information as described above a new license file will be sent to you To activate the full version of the software replace the old license file with the new one as follows Run the SPC Inline program The Demo Version Notification dialog opens Click the Browse button The Open dialog opens Select the new license file Click the Open button The Open dialog closes The complete file name of the license file is displayed in the Locate valid spcinline lic file field
25. active production button Gauss Curve a Select Remote from the shortcut menu All Violations Tolerance Violations Time Violations gt The SPC Remote program opens Device Status 45 Network Nodes 13 11 2007 10 59 23 13 11 42007 11 01 23 13 11 2007 11 03 23 E SPCinline Server Pr Ping E Ask TestMsg Add Mew Edit Remove Deactivate Remote e Metal detector 4 Metal detector 4 Metal detector 4 amp Warning SS Warning Warning 46 13 11 2007 10 59 23 13 11 2007 11 01 23 13 11 2007 11 03 23 _________hdetal detactay 4 Delete 4 Metal detector 4 You can launch SPC Remote application from the Network Configuration window also To do this Open the Network Configuration window Right click on a device node in the Network Nodes tree Select Remote from the shortcut menu The SPC Remote program opens Note SPC Remote is an optional feature which can be launched only if the license is purchased The Message Pane Messages that are generated to inform the user about certain events are displayed in the message pane of the Monitoring window Messages are classified into three types information warning or alarm The pane may contain 300 messages When this number is reached the oldest message is deleted To manually delete one or more messages Select one or more items from the list Right click on the selecte
26. age of Good Production graph Right click an active production button Select Ave of Good Production from the shortcut menu gt The graph window opens To view the Gaussian distribution Right click an active production button Select Gauss Curve from the shortcut menu gt The graph window opens To view the Classification graph Right click an active production button Select Classification from the shortcut menu gt The graph window opens 41 gt Sartorius ProlontroelHotine Average of Production Graphic Evaluation joo Fle View Evsan Configuration Window Help SRO ARE Bi Average of Total Production Average Value 260 053 g print preview nn O gt OO BBB cose Averac 42 Using Graphs When right clicked there are three menu commands available directly in the context menu of the graphs Print Refresh and Close To print a graph Click the Print menu item The print preview window opens Click the Print button in the upper left hand comer of this window The image is sent to the printer Note Please keep in mind particularly if the production batch is still running that the graph values on the printout are just a snapshot of the values that were current at the time the graph window was opened To capture the latest graph values Click the Refresh menu item To close the graph
27. arm List window with the time violation logs for a specific produc tion batch To view the list of both tolerance and time violations Right click the active production button Select All Violations from the shortcut menu This opens the Alarm List window with both the tolerance and time violation logs for a specific production batch Viewing Statistics Select one or more items in the Alarm List and click the Statistics button to view details including the times when violations occurred See Monitoring Events for more information Average of Production Viewing the Device Status 2 When an error occurs in the checkweigher Classification a notification is sent to the server Ave of Good Production Ave of Total Production Gauss Curve To view the latest error All Violations Tolerance Violations Time Violations Right click the active production button Select Device Status from the shortcut menu Remote gt A window opens displaying a description of the error The Device Status shortcut menu item is disabled if there are no error messages from the checkweigher A warning symbol Ma 333 W 333 in the lower left hand corner of a batch button indicates that a device error has occurred in that batch Average of Production Checkweigher Remoting FON To launch the SPC Remote application Ave of Good Production five OF Tokal Production Right click the
28. bom Post 53000 Ads ew Ea Dewe Perky gt CROS 2005 13 42 16 Prong iP 152 168172111 gt CEVOS 2005 13 42 34 Perpa fired ot gt O52006 142 Pingng IP 192 16813275 gt OSI 2006 124230 Request tmed 5 OORA 124238 Prang IP T 168 122 73 P naaie Laas Request red out Network Nodes m SPCinline Server Ping All Add Mew Device Refresh To open the Network Configuration window Open the Configuration menu in the main window and select Network or Click the Network Configuration button on the SPCInline toolbar gt The Network Configuration window opens Adding Devices If no devices have been registered yet for example if your are using the program for the first time Right click on the SPCInline Server icon gt A shortcut menu opens Select Add New Device Checkweigher Settings Machine Number on Device Number p 2 Device Type EWK Serial Mo BDE 220 746 647 IF Address 192 168 1 222 v E 53001 59000 Add Hew N Edit Remove Network Nodes mj SPUlnline Server ar Ping 222 Ask TestMsg Listening to Port Sending Data from Port Add New is Edit Remove Deactivate Remote amp Device Entry Machine Number Device Number Device Type g EWK i Serial Mo PO IP Address Listening to Pork 59001 59000 Sending Data from Port 20 If one or more devices have already been registered L
29. cherstic I Total Production Rejec I Good Production Metal W Ignore Empty Intervals fh Show Indnvidwal Weights Cancel Print 62 O O Select Show Individual Weights to display the weight values of each interval Select Ignore Empty Intervals to suppress empty intervals from the report Click the Print button The Report Viewer opens Click the Print Report button on the tool bar in the Report Viewer to send the report to the printer To evaluate data in archived records Activate the Evaluate from archive option in the upper right hand corner of this window The dropdown list is enabled Select a database name from the list Proceed as described above to print the report To close the window Click Cancel Graphic Evaluation To open the Graphic Evaluation window Open the Evaluation menu in the main window and select Graphic Evaluation gt The Graphic Evaluation window opens Select a type of graph from the drop down list in the Graph Type field gt The subsequent fields are enabled By default the Period From and Period To fields show the date and time of the first sample and the current date and time respectively You can edit these values as desired For details on entering the desired article machine and batch numbers see Auto matic Statistics Note Wildcards are not permitted when defining
30. d items gt A shortcut menu opens Select the Delete menu item gt The selected items are removed Ofin Batch Processing OVE Teke Sice Deere Sabet Product Date Tee Aedes He Ache Dope Wha He Mahra Hi Fikret i DO asam Tr LEEI SZ TUHA CHUHES wEIGHERE A ESSPOL Preda D se nee i VE TUNAGRINES WEA mi DO Pode E ana eam j 3 WEIHER E mig F E FISa P 5 5 WEIGHER E g EFO G iagi eu d 4 A i ee ce E aai anew AAG i mi E S500 201 PM z F WEIGHER E med EPO G Wee cee oe 1 WEGHLA mi GO E mam enu 3 3 wiii mi Ei I Prom ie bah Foe ccsccbane I SFT SAE ART PM Pa 9 15 2006 41735 PM 10 Check All Products Running Offline Batches To run an offline batch Connect the disk stick to a USB port Note The disk stick must contain the XML files from a checkweigher SPC Inline requires the correct directory structure on the disk stick Any changes to the structure may cause errors when reading the files When loading the files from the checkweigher the appropriate structure is created on the disk stick by default Open the File menu and select Offline Batch The Offline Batch Processing window opens Select the source drive The list of products is displayed These are the products that were used during offline batch processing Note The items in the list that are displayed in red font are either erroneous or may already exist in the database You may check
31. e options for re sizing the report To change the size of the report as dis played Select Page Width to adjust the width of the report to the window Select Whole Page to show the entire page in the window Select a specific zoom factor 500 200 150 100 75 50 or 25 Select the desired zoom factor gt The page view is resized accordingly To search for specific texts within the report Enter the word or phrase you wish to find in the Search Text field Find Next Click Find to proceed gt If the text exists the first match found is highlighted O Click Next to search for the next match going on until the end of the report is reached if desired To print the report document m Click the Print button i Print gt The Print dialog opens General Select Printer Specify your printing preferences such as ladd Printer cA Microsoft Office Document Imag era number of copies paper layout pages to be printed etc Status Ready T Piinttafle Preferences Click Print to print the report Location Comment Find Printer Page Range All Number of copies ft Selection Cil C Pages fi F l qj Enter either a single page number or a single pi 2 page range For example 5 1 Cancel oy 75 Using SPC Inline Services J SPC Inline Listener Service Manager Listening to client machines
32. e server and the device is shown in the Reply box 23 Checkwergher Settings 24 Network Nodes Machine Humber Device Number Device Type Serial No IF Address Listening to Port AEP At Offs AP SPCinline Server Add New Edit Remove Deactivate Remote 012 Ew gt Pinging Devices To test device network connections you can send a ping request to each device Right click on a device node in the Network Nodes tree Select Ping from the shortcut menu If the device is not connected or could not be reached a red circle with an exclama tion point is shown next to the check weigher icon in the Network Nodes tree If the ping request is successful the red circle will disappear Note Results of the ping request are displayed in the Reply box in the Network Configura tion window You can also ping a device in the Check weigher Settings box Select a device node The Checkweigher Settings box opens with the data from the selected checkweigher BOE 220 746 647 Click the Ping button paara oy 59001 To ping all devices at one time Right click on the SPCInline Server node Network Nodes TA m Ping All Add Mew Device Refresh Select Ping all from the shortcut menu Managing Product Types Checkweigher 2 Product Type General IMS Limita Product Type Number The list of produc
33. eft click on any device node The Checkweigher Settings box opens on the right hand side Click the Add New button in this window Or after selecting a device node Right click on the device node A shortcut menu opens Select Add New As a result of the above actions The Device Entry window opens Enter the required device information Select an appropriate Device Type If the MDP device type is selected an additonal option is displayed cay Device Entry Machine Number O Select Metal Detector gt Checkweigher Standard if products will pass through Device Number Device Type MDP the metal detector before passing through Position the checkweigher Otherwise select Metal Detector gt Checkweigher Standard Checkweigher gt Metal Detector Checkweigher gt Metal Detect Bc Hag Ef Elal Velector Note Serial No If no checkweigher is installed in the pro P tides m duction line select the Standard position o Rel 8001 Click OK to save the data Sending Data fram Port 59000 Note Cancel IP addresses must be entered in the correct format otherwise an error message is shown after you click OK and the infor mation is not saved Network Nodes Editing Devices Right click on a device node in the Network Nodes tree Ask Jesttieg Select Edit from the shortcut menu Add New Remove Deactivate gt Device Entry a gt
34. eigher specify number of licenses 62899XCombi License per connected EWK Combi or CoSYNUS checkweigher specify number of licenses 62899XMDP License per connected Metal Detector Premium specify number of licenses 62899XM License for the SPC Inline full installation only 1 per customer 62899XM L License s for additional SPC Inline Compact Installation versions specify number of installations up to 255 62899XV License per connected Vistus metal detector specify number of licenses up to 255 85 To obtain the installation code Click the Show License Viewer link in the demo version notification dialog or click the Windows Start button and select Sartorius SPCInline License Viewer from the Start menu gt The License Viewer window opens Y Licence Viewer Manufacturer Company Licence File Code 3 67945315 5 SPCinline Server DEMO VERSION Number of licences per Computer 1 thereof 0 are available Licence is valid until 11 28 2007 S amp S Checkweigher SYNUS EWK DEMO VERSION Number of licences per item 3 thereof 1 are available Licence is valid until 11 26 2007 CJ Checkweigher CoSYNUS EWK Combi DEMO VERSION Number of licences per item 3 thereof 3 are available valid for 30 day s Metal Detector Premium DEMO VERSION Number of licences per item 3 thereof 2 are available Licence is valid until 11 26 2007 SPCRemote DEMO
35. ening This is necessary if the server socket is currently open or running Right click on the icon Select the Settings menu item gt The Listener dialog appears Modify the fields as needed The IP Address field refers to the IP address assigned to the server hosting the SPC Inline application The value of the IP address should appear in the checkweigher s Server IP parameter in the TCP IP Configuration dialog 614 1 The parameter XML Client TCP Port number should have a value similar to the value of the field Listening to Port The parameter XML Server TCP Port number should have a value similar to the value of the field Sending Data from Port In the same dialog Selection criteria for partly empty intervals refers to the percentage of the number of individual weights that are missing from the expected number If the given percentage is reached during batch processing this will be considered as down time Important note The detection of down times only works if the interval in the checkweigher is set to time and not to pieces Click OK to save the changes gt The settings dialog closes 71 Installation List IP Address Date Created 192 168 1 123 6 12 2008 11 23 47 AM IP Address 000 000 000 000 Close IF Address 192 168 1 123 Close 78 O From the shortcut menu select Start Listening The new setting
36. ep a e O Click the OK button Operation Mode gt The Advanced window closes Note The Advanced button will only be enabled if the Production Monitoring option is activated for the checkweigher From the Product Type window click the Store button to save the product type Product Type gt You are prompted to create a new product type 26 lt gt Product Type General IQMS Limits Trend Control Enter parameters for each weigh line Weigh line no 1 Trend controller Ors es C No Target value 00g Control factor a gis Control limits 0 0 g Control gain 10 0 Control limits o0 g Control gap o g Sample g pes Dead number 0 Store Operat Mode Cancel Enter parameters for each weigh line Weigh ine no j1 Trend controller _ C No If you click Yes follow the same proce dures as above Otherwise The Product Type window closes The Product List window refreshes the list showing the new product type Setting up Parameters for each Weigh line The parameters for the trend controller are applied to each of the weigh lines of the checkweigher To setup weigh line parameters Select a weigh line number from the Weigh line no dropdown list on multi line systems Enter values in the fields Select another weigh line number from the list The previous settings are saved to the previously selected weigh line The field values
37. f days for retroactive evaluation defines the end date of the default archiving period For example if the number of days for retroactive evalu ation is 30 A and the date of the latest recorded sample is February 3 2006 B then the end date is January 4 2006 The program counts backward from sample date B by A number of days 12 To confirm changes Click OK The settings are saved and the window closes If you click Cancel without having first clicked Apply you are prompted to confirm that the window will be closed without Saving changes To close without saving changes Click Yes To cancel the operation and leave the window open Click No The window remains open Note Some changes might not be take effect until the application is restarted Alarm Configuration Open the Configuration menu in the main window and select Alarms gt The Alarms Configuration window opens Pane OE lla Ed ee ee i i ee ee To create a new setting for a certain article checkweigher combination Click the New button New Copy eo dete etc Pe wa a gt The drop down lists for selecting article and oo mann T Bache Nn weigher number appears Select an item in the Article Description field Select an item in Weigher No field Note An asterisk in the Article Description or Weigher No field means apply to all articles or apply all checkweighers
38. g opens auto matically when launched for the first time To open the Auto Archiver Service Settings dialog Right click on the icon Select Settings menu item 79 a Auto Archiver Enable auto archiving Runtime settings Mo E Tu C We E Th L Fr E Sa C Su Interval hours Fixed time comma separated 21 00 Use the same archive database for months Curent archive database adb200711_200711 Save Close Fixed time comma separated Use the same archive database for month s Current archive database _ 200711 80 The Service Settings dialog appears Select the Enable auto archiving option to activate the service Select the desired day or days when the service should archive the records Specify the time interval by selecting one of the options Interval Select the interval in hours 3 6 8 12 hours Fixed time Specify the times in 24 hour notation separated by commas e g 8 00 13 30 21 00 The archive database is automatically named and created The database will be used for archiving for a time period of 1 2 3 6 or 12 months By default the database is used for one month only after which a new one is created You may select the desired duration from Use the same archive database field Click Save when done Click Close to close the dialog Automatic Statistics Printout The statistics report printouts statis
39. ge Value 241 915 cheese nee Set Default Graph Set Limits Set Button Size Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve k All violations Tolerance Violations Time Violations Device Status Femote Viewing Graphs Clicking an active production button will display the enlarged version of the default graph in a separate window You may select and display a specific graph using the shortcut menu To view the Average of Production graph of a running batch Right click an active production button Select Average of Production from the shortcut menu The graph window opens To view the Average of Total Production graph Right click an active production button Select Ave of Total Production from the shortcut menu Set Default Graph Set Limits Set Button Size Average of Production Classification Ave of Good Production Ave of Total Production k gauss Curve All violations Tolerance Violations Time Violations Device Status Remote Average of Production Classification Ave of Good Production Ave of Total Production G aL ss Curve All Violations Tolerance Violations Time Violations Device Status Remote Average of Production Ave of Good Productio Ave of Total Production Gauss Curve All Violations Tolerance Violations Time Violations Device Status Remote To view the Aver
40. he Help Window Open the Help menu in the main window and select Contents Context Sensitive Help Fi gt The Help window opens and shows the About table of contents Select Context Sensitive Help from the Help menu or press F1 Context Sensitive Help Fl ju gt The Help window opens with a default topic related to the active window ensitive he Customizing Settings Customize Archiving Emal Compary Meriter Loge Button Sine 100 272 x 196 M Graph Limits C TU T01 f TU2 TO2 Company Monitor Loge Dave the commurecation bog ile in Ihis path ee 3 Purge communication log fie if this size has been reached 10 MB 10 System Settings Application properties that do not require frequent reconfiguration can be modified in the System Settings window We recom mend configuring these settings immedi ately following installation of the program Open the Configuration menu in the main window and select System Settings On the Customize page of the Company dialog page enter your company s name under Company name on printout This name is included in the header of report printouts On the Monitor page of the Customize dialog page you can define the size of the production monitor button by selecting a size from the drop down Button size list To define the display of limits selec
41. ick the Edit button Or Double click on a product type The Product Type window opens containing the saved parameter values of the selected product Modify the fields as needed Click the Store button to save the changes The Product Type window closes aTi preda Lint Motel Deter teat Ole Selen ss etal Detect MDA wil Prahat aiie Petsa Atci Denpi Gate ire 5 3 7 VOIR LHET i F faded hjer i iiaa UHTI a 1 1103 LNT Est Borore Copy ha weigher Addition Ea Remove Chon Copy to Select one or more metal detectors m Vistus 2 LINE1 Vistus Line 1 Copying Product Types A product type can be copied from one metal detector to one or more metal detectors Select one or more product types from the list Right click on the selected product types Select Copy to from the context menu gt The Copy to dialog opens Check one or more metal detector numbers from the list where the product types will be copied Click the OK button gt The dialog closes gt The selected product types are copied to the selected metal detector line numbers Removing Product Types To delete one or more product types Select the product types from the Product List window Click the Remove button gt You are prompted to confirm Click Yes to proceed 37 Monitoring Production Batches Type Date A Warning 13 11 2007 10 59 23 Me
42. ile Arranges windows as tiles Close All Closes all open windows Help Menu Contents Opens the Help window Context Sensitive Help F1 Opens the Help window showing the relevant topic About Opens the About window n i Context Sensitive Help Setting the Password Once you have logged in to the SPCInline program you can change the password at any time Open the File menu in the main window and select Set Password New Password Confirm New Password Enter the current password in the Old gt The Set Password dialog opens Password field Enter the new password in the New Pass word field and again in the Confirm New Password field Click Ok to save the new password If you enter the old password incorrectly or if your entry in the New Password field did not match your entry under Confirm New Password the new password is not saved and an error message is shown Click Cancel to retain the old password Logging Out If you log out while batch processing is in progress the application is locked to prevent unauthorized use and processing continues in the background Other users can access the program only by entering a valid password ae r Open the File menu in the main window Sartorius ProControlalntine eas and select Log Off gt A message box opens prompting you for confirmation Click Yes Opening t
43. ing the Statistics Window The main statistical information in the Statistics Window is divided into five pages as follows The Total Production page shows statistics on overall production the Good Production page shows details on good production the Accepted page contains information on the distribution of good production the Rejected page shows details on rejected pieces the Miscellane ous page shows miscellaneous information such as evaluation range and ignored pieces the Metal Detects page shows m Batch Number Interval 787 7327733 4 gt Article Description YZ Tuna Chunks Total Production Good Production Accepted Rejected Miscellaneous ee Nomanat 270 00 9 Tae 10 00 g Densi Max S D 0 48687 g Intermediate Accumulated Average Value 260 111 g Date 0 o n th 1 5435 g Ime f3 F 5 25199 f Ind Values Piir N 2451 g Harir information about metal contamination and the status of the metal detector during the batch period and the Completeness page shows package completeness infor mation The Intermediate and Accumulated pages are shown for each of the five pages described above The Intermediate page shows data on the latest sample by default and the Accumulated page shows the cumulative statistics on a particular pro duction batch from the first to the latest sample The data on the Intermediate tab can be switched to different sample
44. iolations Tolerance Violations Time Violations Device Status Remote Set Default Graph Sek Limits Set Button Size Average of Production Classification Ave of Good Production Ave of Total Production gauss Curve All violations Tolerance Violations Time violations Device Status Remote tr a p Maco mo M o Set Default Graph Set Limits TU1 TO1 Set Button Size Note If a batch is started by a stand alone metal detector the only available menu item is Close If clicked this will close the production button Setting Limits To set the limits of the mean value graph Right click an active production button Select the Set Limits from the shortcut menu Select a limit from the sub menu Note The Set Limits menu is available if the default graph is a Good Production or Total Production Setting Button Sizes To set the size of the production button Right click an active production button Select the Set Button Size from the shortcut menu Select the desired size from the sub menu ad Total nverege Value a a eerie Lae 40 Set Default Graph Set Limits Set Button Size Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve All Violations Tolerance Violations Time Violations Device Status Femote of Production Good Production avera
45. is applied To open and use the Installation List dialog Right click on the icon Select Installation List menu item gt The Installation List dialog appears The list contains the IP addresses of the SPC Inline compact installations Additional Master PC within the network including the IP address of the server where the listener service is installed To add an IP address to the list Click the Add button gt The Add dialog displays Type IP Address Click the Save button to add item to the list To edit an IP address to the list Select an item from the list Click the Edit button gt The Edit dialog displays Modify the IP Address Click the Save button to save changes To remove an item from the list Select an item from the list Click the Remove button ee gt The Remove confirmation appears Installation List Click the Yes button to remove the item from the list YD re you sure you wank to remove 192 168 1 1235 Automatic Archiving The Auto Archiver automatically creates a backup of statistical records at a specified interval Records are transferred from the main data storage to the archive data storage area To open the Auto Archiver service Click the Windows Start button and select Sartorius SPCInline Services Auto Archiver gt The icon of the service appears in the system tray gt The Service Settings dialo
46. munication Logs window opens Lange wal be popad shan te lie coe maces 136 Logged data is shown in the Communica tion Trail box You can choose between two logging modes from the Logging Option box Select Trail information only to view one line entries containing only a brief description of the communication activity and a time stamp Logging Option Trail information only Show all contents Select Show All Contents to view the contents of the data being transferred to and from the checkweighers By default all data from all checkweighers connected to the server is displayed in this window If you prefer to monitor only a specific device 65 Select an item other than ALL from the Ani REEL drop down list in the Checkweighers Cw W003 IP 192 168 172 75 Cw W001 IP 192 168 172 73 field CW 333 IP 192 169 172 111 ALLE gt Only the data pertaining to the selected item checkweigher is displayed If you do not need the communication log file Deselect the Enable Communication Logs option in the top left hand corner of this Enable Communication Logs window lt gt Communication Logs The program automatically deletes the data in the log file when a certain number of lines has been reached You can delete this data manually at any time To do this Click the Clear button at the bottom of the Communication Logs wi
47. n Window The Statistics Selection window is similar to the Alarm List window but shows the list of the production batch data without any information on violations To open the Statistics Selection window Open the View menu in the main window and select Statistics or Click the Statistics button on the SPC Inline toolbar The Statistics Selection window opens To view statistics on a particular batch Select an item from the list Click the Statistics button at the bottom of the window or Double click on the selected item 53 gt The Statistics window opens Machine Hurk Batch hanter x faz Bui g Total Paadution Rood Production Accepted Nejaciad Micelles iiaiai Eisiact Somers 00g Ta OO gq Desy Too bize 5D GAN g intemrectiate Accumulated vein al 70 y a f t TM g T Hunter T3 pa T wege F hg T God Porter 1m0 ha of TU pew Mo of TH o pea Faol TUE ji Dees Moot Tot 20 pea 279 Maa aie avam a To print the list Click the Print button in the bottom right hand corner of the Statistics Selection window rar Pin gt The Report Viewer opens Click the Print Report button on the toolbar in the Report Viewer to send the report to the printer To close the Statistics Selection window Click the OK button in the bottom right hand corner of the window gt The window closes x o 54 Us
48. n a ooo minute before the start time of Shift 2 the ste paara i stop time of Shift 2 is one minute before Month 3 aa m7 z the start time of the Shift 3 and the stop p DLE earan time of Shift 3 is one minute before the ue E start time of the Shift 1 Change the value in the First day of week field if desired Set the start dates for months 1 through 13 The start date of Month 1 should be before the start date of Month 2 the start date of Month 2 should be before the start date of Month 3 and so on Click OK to save your changes gt You are prompted to confirm YD Are you sure you want to save the changes in the settings Click Yes to save ce 18 Language English GB OK Cancel Setting the Language Open the Configuration menu in the main window and select Language gt The Set Language dialog opens Select the desired language to be used Click the OK button gt You are prompted to confirm Click Yes to commit changes gt You are asked to restart the program before the change takes effect Registering Devices gt Natwork Configuration Hehsok Noder S SPOirden Server P Cw id 192 160 172 111 Ow wood 13216813275 Ow WOOL 13216913273 Number of device boemer avedabie 2 Checkwenighet Settings Machine Number MI Once Hurri wl Oevice Type mK IP Addes CACI z 2 Latarang to Post socom Sordin Dota
49. ndow gt You are prompted to confirm before the data is deleted Click Yes to proceed To close the window Click the Close button 66 Atco tuabec PF aj f Machine Number rF rt C C COUR Bachineter T al Pend aoe 2007 Men er E 2070072007 pex E F Donie pasco dats jichivrg oj o l e E 123 72 Tuna Chunks Batch Number T aj Fero E0 s hessa pe e seu Delete source data Huchvnol Backup and Archiving ss Archiving Samples To open the Backup window Open the File menu in the main window and select Backup Process Data The Backup window opens To backup saved data Click the Search button magnifying glass next to the Article Number input field The Item Selection window opens Select an article from the list Note Wild cards are permitted in these fields An asterisk can be used as a placeholder for any number of characters a question mark stands for a single character To represent all possible values enter only an asterisk without any other characters Follow the same procedures for the Machine Number and Batch Number fields Enter the starting and stop times and dates for the desired period in the Period fields 67 Period J26 U6 2UU Y j 16 5 I Delete source data Archiving Backup Process Data xX The system is busy Please wait aedepeyay 68 The data
50. older Click OK to proceed Note bot Data x If the SQL Server account is not permit SEE nt mennad aa mne Yaten me Scans Seed ie tiene co a Ste ted to create a database file in the default database file directory an error message is shown In most cases you need to browse to the following directory Program Files Microsoft SQL Server MSSQL x MSSQL Data where x is any number e g Program Files Microsoft SQL Server MSSQL 1 MSSQL Data The Database Name field also shows a default value You can edit the name as desired If the name you enter is already in use an error message is shown To begin exporting data Click the Export button gt You are prompted to confirm Click Yes to proceed gt A progress indicator is displayed Once the data has been successfully exported the database name is shown in the Archived Databases list This list shows information about the databases in which archived data has been exported 450MB 07 09 2006 10 37 47 To close the window Click the Close button 71 The Report Viewer Using the Report Viewer Reports are opened in the Report Viewer before being sent to the printer This lets you check the layout page count and a fs content before a hard copy is produced You can cancel the print job before print ing if desired Sartorius AG Use the following buttons to navigate the pages of a report
51. oring Statistics All violations Tolerance Violations R Time violations Communication Logs To view the list of time violations Open the View menu and select Time Violations or Click the Time Violations button on the SPCInline toolbar gt The Alarm List window opens To view a list of both tolerance and time violations Open the View menu and select All Violations or Click the All Violations button on the SPCInline toolbar gt The Alarm List window opens Level Machine Number Weiger Nubes Demiin 323 ma TU Vielstion a 333 333 Test 0 gt Max 0 333 333 E cenh Repcts I 33 Teas D gt Ma SD A mm m Coedstos Masa z Nawal J1 Vrda PELIN n ie mi mr a Men i Honna eT Phen mM mar Mean Hamina ZVL PMD 111 Tir iD Mim SD ROLE a 11 Tar ify Mee S BALE bh m1 mar eed Pnpocls Le Then m mar T1 Viisi Ranier cuy Toro mM ma Ds Me So FL ao PEHD il mar i ox eT gt dee 5 Pewee dea Mana r hams 1 Virion ZIAN 130 m 77 Mean Nonna mina 103400 m ra e Mean lt Nominal mney 103400 m m DMa 5D ZNO 110 m ALA D gt Max D zaoa wauw m 77 pods Rojcts panit ru 1034 00 m 77 11 Virar FEUI nu 10310 m 77 DMa 0 Bm 103400 m va YD Are you sure you want to delete the record Cey e Using the Alarm List Window To view details on a violation Select the desired item from the Alarm Settings list Double click on the selected item
52. r misuse of the product Launching the Application SPCIniline Windows Macks Player ue mere D y vam terere Password Cancel Starting the Application Double click the SPCInline shortcut on the desktop or Click the Windows Start button and select Sartorius SPCInline SPCInline from the Start menu If you have not licensed the full version the demo notification dialog opens Click Continue to proceed The splash screen opens After a moment the splash screen closes and the Operator Login dialog opens Logging In Enter the password Click Ok Note You are only permitted three login attempts The third time an invalid pass word is entered the application shuts down automatically The initial password for the application is admin You can change this password if desired The Main Window Once you have entered your password the main window opens This window includes a menu bar and the SPCInline toolbar You can use keyboard shortcuts to access menu commands by holding down the ALT key and pressing the letter that is underlined in the menu name or menu item ation A Window Help E w iP Bie Listening to cent machines File Menu Product Type Opens the Product List window Backup Process Data Opens the Backup window Export Achive Data Opens the Export Archive Data window Offline Batch Opens the Offline Batch dialog
53. s done using the Email Notification service To open the Email Notification Service manager Click the Windows Start button and select Sartorius SPCInline Services Email Notification gt The icon of the service appears in the system tray gt The service settings dialog opens automati cally when launched for the first time To open the Email Notification Service dialog Right click on the icon Settings Select Settings menu item Restart Exit 83 Email Notification Activate Email Notification SMTP Server Local IIS Remote Sender s Email Address vs O spcinline sartorius com SMTP Server Settings TF Server Name Recipient Full Name localhost John Doe Username Email Address Administrator John Doe sartorius com Password Add Remove Beno C Use Default Credentials Name Email John Doe dohn Doe sartonus com A 84 Recipient Full Name John Doe Email Address John Doe sartorius com re gt The service settings dialog appears Select the Activate Email Notification V O gt option to activate the service The input fields are enabled Select an SMTP Server If Local MS is selected as the SMTP Server Microsoft Internet Information Services must be installed If Remote is selected as the SMTP Server From the Sender s Email Address enter the valid email address
54. s or intervals Use the Interval Browser to navigate to each sample of the batch To print statistical information Click on one of the six main tabs Click on the Intermediate or Accumulated tab Click the Print button The Report Viewer opens Click the Print Report button on the tool bar in the Report Viewer to send the report to the printer 55 56 lt gt Individual Values Each sample has a number of individual weight values To view these values Click on the Total Production or Good Production tab Click on the Intermediate tab Click the Ind Values button The Individual Values window opens To print the Individual Values report Click the Print button The Report Viewer opens Click the Print Report button on the tool bar in the Report Viewer to send the report to the printer Note The number of individual values is limited to 200 To view the Gaussian distribution of the production batch Click the Gauss Curve button from the bottom left part of the Statistics window A graph of the Gaussian distribution is shown To view the average production graph for the particular batch Click the Ave of Production button in the bottom left hand corner of the Statistics window A graph of the production average opens See Monitoring Production Batches for more information about using the graph window To close the Statistics window Click the
55. st changes made to the product list 32 Creating Batch Plans To create a batch plan Select a product type from the Product List window Click the Show Plans button gt The Plan List window opens Click the Add New button Baich Pian gg gt The Batch Plan window opens Article Description fiz3 XYZ Tuna Enter a value in the Batch Number field Machine Number M333 M333 teers plaan O Click Decentral if you want to create F cea a decentralized batch number Click the OK button to save the batch plan gt The Batch Plan window closes gt The Plan List window refreshes the batch plan list You can also create a batch plan without displaying the Plan List window Select a product type from the Product List window 33 34 Click the Plan a batch button gt The Batch Plan window opens Follow the procedures listed above Removing Batch Plans From the Plan List window select one or more batch plans Click the Remove button gt You are prompted to confirm Click Yes to proceed Managing Product Types Metal Detector The list of product types is shown in the Product List window To open the window Open the File menu in the main window and select Product Type Metal Detector peste STL soe gt The Product List window opens Tekid Monel Detector MD Ma fipa me a eo oe
56. t a device node gt The Checkweigher Settings box opens with the data from the selected checkweigher Click the Remove button gt You are prompted to confirm Click Yes to delete Network Nodes Checkwengher Settings Machine Humber Device Number Device Type Serial No IP Address Listening to Port Reply gt 30 06 2008 09 26 02 30708 2008 09 26 02 192 165 1 222 30708 2008 09 26 02 192 165 1 222 gt 30 08 2008 09 26 02 192 166 1222 30708 2006 09 26 02 Remove Deactivate O01 m 2 EWK BOE 220 746 647 192 168 1 222 v fh 59001 Connecting to IF 192 166 1222 Sending Command ml to IF Command sml sent to IF Reply received from IF Disconnected from IP 194 168 1 222 Close Note A device that is currently processing a production batch can not be deleted Retrieving Device Data To confirm that a network node is a check weigher you can request an XML test message containing the device information directly from the checkweigher in question Right click on a device node in the Network Nodes tree Select Ask TestMsg from the shortcut menu The request takes a moment to process To request a TestMsg xml file in the Checkweigher Settings box Select a device node The Checkweigher Settings box opens with the data from the selected checkweigher Click the Ask TestMsg button The communication between th
57. t an item from the Graph limits drop down list Select T1 to T1 or TU1 T0O1 if you wish to have only the lower and upper warning limits shown Select T2 to T2 or TU2 TO2 if you wish to have the lower and upper tolerance limits shown as well Open the Logs page of the Custom ize dialog page to define the directory in which log files are saved click the Browse button to browse to the desired directory gt The Browse For Folder window opens Select a folder from the list Dekon Click the Make New Folder button if you B my Documents wish to create a folder My Computer E my Network Places Click OK to proceed E Recycle Bin Make Mew Folder If desired you can change the size limit Purge communication log file if this size has been reached for log files under Purge communication 10MB log file if this file size has been reached aoe a On the Archiving dialog page you can No of statistics to be kept change the values for each statistics type as long as the new value is within the per mitted range If you enter a value outside this range the field returns to the default value These values define the quantity of statistics to be retained for each batch during archiving Hourly 24 Weekly 4 Batch 30 Monthly ge Shift al Yearly is Daily TE How many days to be retroactively evaluated fio The number o
58. t types is shown in the Product List window To open the window Open the File menu in the main window and select Product Type Checkweigher The Product List window opens Select a checkweigher from the dropdown list The product types related to the selected checkweigher if any are displayed Adding Product Types From the Product List window click the Add New button The Product Type window opens Note The entry fields may vary depending on the release options that are activated in the checkweigher If the Check For Completeness option is activated the Completeness tab will appear in the dialog Enter the required product type informa tion Click the Operat Mode button to change the settings of the Operation mode 25 V lt 2 Operation Mode The Operation Mode window opens Operation Mode QMS Weigher X TO2 rejection Yes No Variable Limit L1 Yes C No Click the OK button Variable Limit L4 Yes C No O Modify the settings if desired gt The Operation Mode window closes Depending on the settings some of the fields in the Product Type window maybe altered Active TUT Yes C No Evaluation range 50 0 O Click the Advanced button to change the settings of the Production Monitoring option gt The Advanced window opens Enter parameters for each weigh ine Weigh inero i z Modify the settings if desired Production Monitoring a
59. tal detector 4 A Warning 13 11 2007 11 01 23 Metal detector 4 A Warning 13 11 2007 11 03 23 Metal detector 4 M ew ees ewww s 2m ow os HRH DA Ma 38 99 1368 nl Set Default Graph gt y Total Production Set Limits gt Good Production R Set Button Size gt Classification 5 Gauss Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve All violations Tolerance Violations Time Violations Device Status Remote The Monitoring Window Each production batch is represented in the Monitoring window as a large button Each of these buttons shows the activity of the batch alarm icons for violations that occurred and the total production graph To open this window Open the View menu in the main window and select Monitoring or Click the Monitoring button on the SPCInline toolbar The Monitoring window opens Each on going batch is represented by an active production button as seen in the figure By default the total production graph is displayed by the active button You can toggle through different graphs To do so Right click an active production button Select the Set Default Graph from the shortcut menu Select a graph type from the sub menu et bie eI Le eh S Oe gt y TU TO 1 Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve All V
60. tatistics to print Statistics Type Next print time Hourly Print every 1 hours Shift Daily C Weekly Monthly C Weekly C Batch 82 If Send to printer is selected specify the name of the connected printer hardware To do so Click the Select Printer button The Select Printer dialog appears Select the name of the desired printer from the list Click the OK button If Save to pdf file is selected specify the directory where the files will be stored To do so Click the Browse button The Browse for Folder window opens Select a folder from the list Click the Make New Folder button if you wish to create a folder Click OK to proceed Select the statistics types to be printed regularly For the hourly statistics you may want to specify the interval in hours The default is 1 hour meaning that hourly statistics will be processed at the end of every hour Click the Save button to save the settings Sunes aes Wane gt The next printout processing schedules are Statistics Type Ned paint Gre displayed in the Next print time column M Hourly 11 21 2007 4 00 00 PM Prien N Shows Click the Close button to close the dialog Shift 11 21 2007 3 00 00 PM M Daily 11 21 2007 9 00 00 PM C Weekly V Monthly 11 30 2007 9 00 00 PM C Weekly C Batch Save Close Email Notification Violations committed during batch processing can be sent via email This i
61. the Remarks field for a detailed description Select one or more products to be saved to the database Select Check All Products to select all listed products 47 Click the Start button to process the batch a so gt The batch is processed Wait until it is ere finished Processing difine batch Ss sees beenee When done click the Close button to close the window Note The offline checkweigher must be registered and activated with a license via the Network Conifiguration window You may enter a temporary IP address but the machine number weigher number and serial code should match the actual values found in the checkweigher 48 Monitoring Events Opening the Alarm List Window As described in Chapter 5 you can open the Alarm List by right clicking on a batch button in the Monitoring window With this method however the list contains only the violations that occurred in a specific production batch Alternatively you can click the corre sponding toolbar button or use a menu command in the main window With this method the Alarm List window shows all violations from all processed batches To view the list of tolerance violations lt amp Sartorius ProControlalntine Open the View menu and select File Yiew Evaluation Configuration Window Tolerance Violation S Monitoring Statistics DRIE or All violations Tolerance Violations Time violations
62. tics are created automatically by the Auto Printing service during a specified interval To open the Auto Printing service Click the Windows Start button and select Sartorius SPCInline Services Auto Printing gt The service icon appears in the system tray gt The Service Settings dialog opens automati cally when launched for the first time To open the Auto Printing Settings dialog Right click on the icon Settings r i iaaa Select Settings menu item Restart Exit auto Printing gt The Service Settings dialog appears C Enable automatic statistics risen OPS Select the Enable automatic statistics option to activate the service gt The input fields are enabled Close E auto Printing Select the output preference V Enable automatic statistics Output preference Send to printer Sends the report file Send to printer directly to the printer Printer name lt default gt O Save as pdf fie Save as pdf file Saves the report file Directoy to the specified directory as a portable document file Select statistics to print 81 as Select Printer Printer Server2 HP LaserJet 1100 MS Auto HP LaserJet 1100 MS on Server2 Adobe PDF Browse For Folder Desktop B My Documents y My Computer My Network Places a Recycle Bin bd Make New Folder Select s
63. to be backed up is filtered according to the dates provided Data that was not collected during the defined peri od is not backed up The default start date is the earliest sample date and the default end date is x days prior to the latest sample date where x is the number of days set for retroactive evaluation on the Archiving dialog page of the system settings Set the delete source data option as desired Specify whether or not samples are deleted after backup Select the Delete source data Archiving option before starting the backup process to have the original sample data deleted once the backup copy has been created This is equivalent to the archiving process as sample data is no longer available for the current evaluations while the current automatic statistics are not deleted Deactivate the Delete source data Archiving option to retain the samples after backup These samples are internally marked as backed up and will not be processed the next time you run a backup operation Click Start backup to begin the backup operation The Progress Indicator dialog is displayed during backup To open the Help program for backup functions Click the Help button or press F1 key gt The Help window opens To view details on the backup process Click the Info button gt The Info window opens 24 07 2006 1657 03 24 07 2006 16 57 09 The window shows the following 02 02 2006 13
64. ver gt The icon of the activated checkweigher A Cw 333 192 168 172 111 changes BP Cw wt 192 168 1222 EP MD 4 192 168 172 113 Make sure you order sufficient licenses with your 62899XS 62899XCombi and or 62899XMDP order codes The number of available licenses is shown at the bottom Number of device licenses 3 available 2 of the Network Nodes tree pane 89 90 m SPClnline Server ec Ping F Cw EP MD Ask TestMsg Add Mew Edit Remove Deactivate Remote m SPClaline Server E Cw 333 192 168 172 111 EP Cw Ww 192 168 1 222 EF MD 4 192 168 172 113 Device licenses are fully transferable in other words you can deactivate a given license for one device and activate it for another This is only possible though for devices of the same type e g EWK to EWK CoSYNUS to CoSYNUS etc To do this Right click on a device node in the Network Nodes tree A shortcut menu opens Select the Deactivate menu item The icon of the activated device changes You can now activate this license for another device Note You can not deactivate a device license while the device it is assigned to is process ing a batch Sartorius Weighing Technology GmbH Weender Landstrasse 94 108 37075 Goettingen Germany Phone 49 551 308 0 Fax 49 551 308 3289 www Ssartorius com Copyright by Sartorius Weighing Technology GmbH Goettingen Germany All rights reserved No part of this publication may
65. window Click the Close menu item gt amp Viewing Violations When preset time or tolerance limits are exceeded a warning symbol is displayed on the batch button in the Monitoring window The following warnings and alarms may be shown Tolerance alarm Tolerance warning Time alarm Time warning Metal Detection Metal contamination Performance validation request Sign of life signal not received Performance validation successful Completeness Good Incomplete overfilled 43 44 Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve Time Violations Device Status Remote Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve All Violations Tolerance Violations Time Violations _ Device Status N Remote Average of Production Classification Ave of Good Production Ave of Total Production Gauss Curve Tolerance Violations Time Violations Device Status Remote To view the list of tolerance violations Right click the active production button Select Tolerance Violations from the shortcut menu This opens the Alarm List window with the tolerance violation logs for a specific production batch To view the list of time violations Right click the active production button Select Time Violations from the shortcut menu This opens the Al
66. ypes 29 Removing Product Types 31 Changing Tare and Density Values 32 Creating Batch Plans 33 Removing Batch Plans 34 Managing Product Types Metal Detector 35 Adding Product Types 4 lt 24 224242 35 Editing Product Types 36 Copying Product Types 37 Removing Product Types 37 Monitoring Production Batches 38 The Monitoring Window 38 Seling LIMIS eee a seen ew eee 39 Setting Button Sizes ss sie0de dees 39 Viewing Grapns 2 52282 2226s lt 0u0 40 Using Graphs 2 2 cexecavce shena 42 Viewing Violations 43 VIEWING Statistics 4 6 6 54 45260 sa es 45 Viewing the Device Status 45 Checkweigher Remoting 45 The Message Pane syerisecrsresss 46 Running Offline Batches 47 Monitoring Events 49 Opening the Alarm List Window 49 Using the Alarm List Window 51 The Statistics Window 53 Using the Statistics Selection Window 53 Using the Statistics Window 55 Evaluating Statistics 58 Automatic Statistics 58 Manual PHMtOULs 2 240 020 ssic0 lt es sa 61 Graphic Evaluation 62 Device Downtime Report 64 Monitoring Data Communications 65 Using the Communication Logs WWinGOW 6 9 9 4 40424 4 4 Row s aks 65 Backup and Archiving 67 Archiving Samples lt ascd 2

Download Pdf Manuals

image

Related Search

Related Contents

to the FORECAST quickstart manual (  HP ProLiant DL320e Gen8 v2 Server User Guide  Fujitsu LifeBook C2230 User`s Manual  Nashua Tape 1207782 Installation Guide  Nokia Multimedia Car Kit Equipo para auto Multimedia  McDougal Littell Online Lesson Planner User Manual  RCA drc6317E Portable DVD Player User Manual  10"  SmartStep Junior User`s Manual  Philips QG3020  

Copyright © All rights reserved.
Failed to retrieve file