1. O c Sou O ol Moderate effect Severe 1 A Unpacking Remove the packing materials unpack the pump controller and the power supply unit Make sure that you have all the following components BOXER 9200 pump CONtrOller ccccceeccceeceeceeeceeeeeeeeesaeeeeeeeeeeees Cat No 9200 000 Power supply UNIt cc ccec cc ecccececeeeceeeeeeeeeeeeseeeeeeeeeeeeseeeseeeeaeeeseeeeaees Cat No 9200 004 ID 4 8mm Pharmed tube wes pace octane ns cee eracoso ee ueteaienssuestaceulase Cat No 15000 028 Please contact your supplier immediately if you notice any one of the components is missing or damaged Note Do not attempt to assemble a unit using damaged components Retain the packaging so it can be used for future shipping The plug in power supply unit is Switch Mode and automatically adjusts itself to the mains power supply characteristics It will work with any mains voltage supply from 100V to 240V The power supply unit is shipped with three alternative plug adaptors to fit European American and UK power outlets Select the correct adaptor for your needs and clip it into the power supply 2 General information on peristaltic pumps Peristaltic tube pumps are ideal for fluid transfer metering and dispensing In contrary to centrifugal and gear pumps peristaltic pumps handle fluids of various viscosities are self priming and can operate in either flow direction With no valves seals or packing to com
2. ON LED On Off switch IMPORTANT CHOOSE THE RANGE THAT MATCHES THE ONE YOU ARE MOST LIKELY TO USE IN YOUR APPLICATION 6 Choosing the correct working range There are 4 working ranges to choose from These working ranges correspond to tube diameters The decimal point is shifted corresponding with the working range R1 ID 1 6mm for lt 10ml R2 ID O2 4mm for lt 250ml R3 ID O 3 2mm for lt 500ml R4 ID 4 8mm for lt 1 litres max display 10 000mI max display 250 0ml max display 500 0ml max display 999 9ml The single ul digit can not be entered in R1 Working with low volume dispenses with large diameter tube will reduce both precision and accuracy of dispenses Using the U D keys scroll to the screen displaying Range Enter Press Enter Using the U D keys choose the range corresponding to your tube diameter and press Enter The display will show the last volume you worked with at that particular range 7 Gravimetric pump calibration procedure Pump flow performance is subject of many factors among them the condition of the peristaltic tube and the viscosity of the reagent It is therefore important that you calibrate the pump before it is commissioned using your reagent and at periodic intervals Carry out the calibration procedure using a volume nearest to the volume you are most likely to dispense 1 Carry out 5 identical dispenses into a vessel and establish the gravimetric volume dispensed in ea
3. Release the pressure by lifting the pressure lever 3 C Replacing the tube Tube need replacing when worn out or wherever you intend to change the dispense volume range in which you work for smaller or larger dispense volumes Up Down U D keys e Scroll menu 7 e Choose range e Increase or decrease value when in calibration mode Lift the pressure lever and replace the tube making sure that you have installed the tube centrally and that the tube is fully engaged inside the tube guides on both sides of the pump head Enter Numeric entry keys STOP dispense Back space Escape GO start dispense 5 Preparing the pump for use Plug the supplied PSU into your power socket and the low voltage plug into the socket on the left side of the unit switch it on by pressing the ON button The green LED on the side and the display will illuminate indicating that the unit is operational The display will temporarily read BOXER 9200 and then the display will show the value it has in it s memory Note the direction of flow The pump can be reversed in flow direction using the slide switch so that you can aspirate any unused reagent back into the reservoir Remote pulse socket for connection to foot switch Power socket for 24V DC 1A Accessory or pulse from a robotic processor Accepts 2 5mm mono or stereo plug Pump direction slide switch Front Left to Right Back Right to Left Power
4. will convert an signal from your computer to a closed circuit on the remote wire connection A USB relay controller is available from many electronic components suppliers Full control of the unit is then possible using the software supplied with such relay The stereo cable to the unit can be fitted with 3 core wire allowing the equipment to send a busy signal back to the controller 9100 9200 START Work State 3V 24V DC U S g PC Busy dispensing Com 0V 16 Care amp maintenance The control unit is maintenance free The peristaltic tubes however require replacement as soon as excessive wear or a large variation in dispense volumes are noticed The operational life of the tubes is a function of the speed load and reagent being dispensed Avoid running the tubes dry for longer than a few minutes Check the peristaltic tubes weekly for signs of excessive wear and replace if required Pump tubes which remain clamped in the pump will deform with time Therefore rotate the tube clip at the top of the pump to open position in order to relieve the pressure whenever the pump is not being used for long periods or overnight 17 Exclusion If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment might be impaired This instrument is NOT suitable for use in explosion hazard environments This equipment is not suitable and should not be used for medical ap
5. Box contains The following Boxer 9200 pump Controller ccccccceccceecceeeeeeeeseeeseeeeaeeeseesaees Cat No 9200 000 BOXER 9200 PSU output 24V 1A with universal plug adapters cccee Cat No 9200 004 This instruction MANUAL cece ceccceececeeeceeeeeeeeseeeeaeeeseeeseeesseeeseeees Cat No 9200 003 ID 4 8mm Pharmed tube with barbed connectors 068 Cat No 15000 028 Accessories amp spares Electronically controlled ID 1 6mm Pharmed tube with barbed connectors 0 c008 Cat No 15000 030 i ID 2 4mm Pharmed tube with barbed connectors cceeeee Cat No 15000 031 dispensing pump ID 3 2mm Pharmed tube with barbed Connectors ccccceeeeeeee Cat No 15000 032 ID 4 8mm Pharmed tube with barbed connectors c 06 Cat No 15000 028 ID 1 6mm Silicone tube with barbed connectors ceeeeeee eee Cat No 15000 035 ID 3 2mm Silicone tube with barbed connectors ccceeee eee Cat No 15000 037 ID 4 8mm Silicone tube with barbed connectors cceeeeeeee Cat No 15000 038 Unoverse 9100 9200 wall mounting bracket stand cccceeeees Cat No 9100 001 FOOL OWO sece cos eaapenan ties neva bases avekatnuouonse e R i Cat No 6013 Product Specification Mains Voltage ccccseececeeeeeeeceeeeeeseeeeesaeeeeeeaeeeeesaees 100V 240V 0 3A MAX 47 63Hz Power Supply Unit output cc cccccceececeeeeeeeeeee
6. ch operation 2 Calculate the mean dispensed volume 3 Using the U D keys scroll to display saying Calibrate Enter 4 Press Enter 5 Using the U D keys correct the volume to your calculated mean volume 6 The display shows C to indicate that you are in the calibration mode and next to it the range which you calibrate i e 1 to 4 T Press Enter and the display shows the volume you intended to dispense The unit is now calibrated with a particular tube within your chosen working range Volumes in R1 will increment by steps of 10ul The unit will store the calibration you carried out for each individual range 8 Prime the tube 12 Interval Dispense To prime the tube direct the dispense tube towards the reservoir and hold down the GO key You can set the unit to dispense any volume for a number of times in predefined intervals As soon as the tube is primed release the key and the pump will stop This feature is useful in repeatable operations either in manual mode or when the dispense head is held by a robotic arm Intervals can be set between 0 5 sec to 100 minutes 9 Entering the dispense volume To set repeat dispensing Press 1 to0 to enter your required volume Note that the digits move from right to left with 1 Using the U D keys scroll to the screen saying Interval the decimal point staying stationary The unit will always display on the top line the range in Enter which you are working To co
7. e in direct contact with the pumped fluid they are ideal for pumping high purity amp corrosive fluids and for contamination free dosing The principle of the peristaltic pump is based on a tube which is occluded by a series of rollers As a general rule the higher the number of rollers and the smaller the tube diameter the lower are the flow rates but better is the accuracy and precision The 9200 controller is equipped as a standard with 4 roller system and 4 8mm ID tube This tube diameter together with maximum speed delivers a flow rate of 480ml min The highest dispense accuracy is achieved by using a semi rigid tube on the outlet of the pump We recommend thin wall tubing such as FEP or PVC tube 3 The peristaltic tube 4 The Control Panel Pressure lever The peristaltic tube is made from Santoprene and the connectors are ee ann Nylon PA Please make sure the reagents you intend to use are compatible with these materials See chart on back page Sows Saad 3 A Clamping the peristaltic tube The pump controller is delivered with a ID 4 8mm Santoprene tube Move the lever up to open the clamp and load the tube as central as possible on the pump s rotor 3 B Releasing the peristaltic tube when you have finished Whenever the pump is not in use for long periods of time it is important to release the pressure off the tube This will reduce tube deformation and ensure that accuracy precision is maximised
8. eeeeseeeeseeeesseeeesneeesees 24VDC 1A Environmental operating temp cccccccsececeeeeeeeeeeeseeeeeeeeaeeeseeesaees 10 C to 40 C Environmental Storage temp cccccsseceseeeeeeeeeceeeeseeeeeseeeeseeeeeeeesaaees 4 C to 60 C Environmental operating RH ccccsecccseeeeceeeeeeeeeeeeeeeseeeeseeeeseeeeeaeeesseeeseeessaees 90 Environmental storage RA sssiscsedissscestivinerenentundidastsavartadwcacdirinaiataaiwedsdartiaeusinsacdonans 95 ui no 9200 on mounting bracket accessory Uno International Ltd 20 Belsize Avenue User Manual London NW3 4AU UK Tel 44 20 7794 4080 FAX 44 20 7431 1426 Email uno boxerpumps com 4 The CE sign certifies that the instrument It is the stated philosophy of Uno International Ltd to preserve the environment wherever possible Uno International Ltd will only use materials and production techniques that cause least environmental damage meets the requirement of the EEC www boxerpumps com directives and has been tested according to the specified test methods Chemical compatibility chart lade Calcium salts lodine and solutions Phthalic acid Chlorine wet dry Lead salts Plating solutions LT Aniline Ethanol Phenol re a Batic Bi E Carbon tetrachloride Ethyl chloride Trichloroethylene Perchloroethylene Chlorobenzene Freon Lacquer Toluene Chloroform Gasoline unleaded Naphtha c Some Q O c a c O 2
9. plications 18 FAQ 1 Q Why does the pump stalls or runs slower than expected when new tubing is installed A A new tube is stiff when new so has to be shaped for some time before it gains it s elasticity Run the pump in continuous mode for a total of approx 5 minutes with the clamp lever half open to start with gradually moving the clamp lever to fully closed position 2 Q have entered a volume but nothing happens after pressing the GO button A The volume you entered is too small for the tube size you use The motor can not turn accurately a very small amount and the dispense is cancelled Use a smaller tube diameter for low volume dispenses 3 Q What is the life of the tube A The life of a peristaltic tube depends on many variants such as speed the reagent it is pumping and temperature In general you should expect approximately 800 hours operation from one Pharmed tube and approx 150 hours from a Silicone tube 4 Q Why does the displayed value sometime jump in double figures A This happens when dispensing small volumes and instrument in course calibration Following the calibration procedure the instrument s mathematical calculation divides the volume to be dispensed by the number of pulses received from the motor s encoder and stores this value If the volume per rotor rotation is relatively large the ratio of pulses to volume is coarse In these circumstances the required volume input does not divide into stored
10. rection Is displayed Press Enter and the screen will display Speed with 8 bars on bottom line Use ar the U D keys to increase or decrease number of bars More bars represent higher speed The pump controller can be used for dispensing or aspirating reagents The slide switch on Press the Enter key to enter the desired speed into the instruments memory the left side of the unit sets the direction that the pumps rotor rotates oo 14 Continuous dispense mode You can not change direction when the pump is in dispense mode You can however press the STOP key change direction by moving the slide switch and continue by pressing the GO To run the pump continuously scroll the menu using the U D arrows key allowing the pump to dispense or aspirate the remainder of the entered volume in the until Constant Enter Is displayed Press Enter and the screen will reversed direction display Constant Stop Go Press the GO button to start the pump and the STOP button to stop it at any point Press the ESCAPE key to leave the continuous dispense mode Please note running the peristaltic tubes dry over a long period will shorten their life 15 Remote control operation The instrument is fitted with a stereo type 2 5mm socket for remote control Through this socket you can plug in the foot pedal which will provide the unit with a GO signal The unit can be controlled from a computer via a USB relay controller which
11. rrect an error entry press the back space key 2 Press Enter and you are asked to enter the Delay in minutes and seconds Any number up to 99 59 will be accepted whereby any number bigger than 59 for the seconds will be rejected Using the numeric keys enter the numbers of minutes and seconds The number 00 00 represents 7 2 second Press Enter to confirm Press GO to start dispensing The unit will remember the volume only for this single dispense Following this dispense the unit will revert to the previously displayed volume In order to enter the typed volume into the units memory press the Enter 3 Repeats screen asks you to enter the number of button after entering the volume repeats from 1 to 98 Entering 99 repeats will result in continuous number of dispenses which can only be stopped by pressing the STOP button Using the numeric 10 The STOP button keys enter the number of repeats Press Enter to confirm The STOP button will stop the dispense immediately The unit remembers the remaining un dispensed volume and will continue to dispense the remainder of the volume as soon as you 4 You can exit the interval mode by pressing the ESCAPE key press the GO key If you prefer the unit to forget the remaining volume press the return key after you pressed 13 Pump speed adjustment the STOP key To adjust the dispense speed scroll the menu using the U D arrows until the Speed Enter 11 Changing the pumps di
12. values and therefore the calculator will round up or down to the nearest whole figure 5 Q Can I leave the unit switched ON throughout the day A Yes you can The dispenser requires very little energy when the pump is not running so continuous power into the unit will not harm it 6 Q Can dispense hot reagents using the dispenser A Yes the dispenser to works safely with media temperatures of up to 100 C Be aware that the internal electronics could be damaged by any ingress of fluids or steam vapours