1. 5 5 OF PRESTIGE LINE THE MICROPROCESSOR The key part of the machine is a new and powerful microprocessor whose processing power is 3 times higher than the usual power required by the operating system thereby avoiding any possible working overload Only 2596 of the integrated memory is used so that later the device could be updated by adding new functions which were not in the original version The updates to be down loaded in the web site www medical italia com are completely free and will ever more improve the already excellent device quality NEW LCD DISPLAY The new Prestige Line is equipped with a new 6 inch LCD color display with 320x240pixel resolution that guarantees a clear visualization of the most important information PRESTIGE LINE t SHOCK MED COMPACT VACUUMED m HR BASIC LASERMED B _ NS LL PR999 7 X Bc 1 _RADARMED 2500 CP 4 uu gi ULTRASONIC _MAGNETOMED Va x 1 E 2 ian _COMBIMED 2200 _PRESSOMED 2900 I messi x TOUCHSSCROLL FEATURE The new touch screen display together with the encoder physical button allows to browse the software s functions in very fast and easy way MULTILANGUAGE SOFTWARE All machines are equipped with the operating software in 5 languages Italian English French Spanish and German and the user can change them according to his needs SMART CARD
2. Spasticity control and reduction through the stimulation with agonists contraction relaxation antagonists mutual inhibition or sensorimotor inhibition Allowing the transcutaneous release of medical substances into the skin iontophoresis Improving or maintaining the joints mobility through the mechanical stretching of muscles connective tissue or reducing the movement problems caused by neuromuscular diseases i e spasticity pain or edema Helping the recovery by increasing the local blood circulation providing a bactericidal effect or altering the electric charge into the damaged area Delaying or eliminating the edema through the action of the muscular pump or through the effect of electric charges on the interstitial proteins electric fields phenomenon Our electrotherapy devices belonging to the Pre stige line are divided into 3 main groups whose dif ferences lie in the wave forms used THERAPIC ia X AI 1 be EX mu b THERAPIC 7200 TH1311 Two independent channels electrotherapy able to supply all the low frequencies waveforms and the cre ation of curve rheobase chronaxie TO THE NTH POWER Electrotherapy benefits from the biological effects obtained from the electric power for a therapeutic use Current is directed into the involved body part having selected it with suitable features to
3. MAGNETOMED 8400 MA1334 only generator The magnetic therapy devices generate a magnetic field with low frequency which can be regulated from 1 to 100 Hz and intensity up to 100 Gauss for each output which has a positive impact for the tissue and bone tissues regeneration MAGNETOMED 7200 desktop portable device with two independent chan nels working as follows Channel 1 and channel 2 working independently Channel 1 and channel 2 working in parallel for total body usage on two solenoids MAGNETOMED 8200 Trolley mounted device with two independent channels working as follows Channel 1 and channel 2 working independently Channel 1 and channel 2 working in parallel for total body usage on two solenoids MAGNETOMED 8400 Trolley mounted device with four independent channels working as follows Channel 1 2 3 4 working independently Channel 1 2 3 4 working in parallel for total body usage on four solenoids Channel 1 and channel 2 working in parallel for total body usage on two solenoids channel 3 and channel 4 working independently Available models MAGNETOMED 7200 MAGNETOMED 8200 MAGNETOMED 8400 MAGNETOMED EXCLUSIVE TREATMENT New Medical Italia design Exclusive MFC Solenoid Patent magnetic induction emitted outside the solenoid is drastically reduced concentrating the magnetic force lines within the solenoid itself thus affecting only the patient and not the operator
4. CP10 Applicators ble solenoid sr o pe MAGNETOMED 7200 1331 only generator _ INDICATIONS Recent fractures and consolidation delays Magnetic fields accelerate the consolidation time ina very high number of cases by stimulating the os teogenic activity at the fracture rime level The recovery process of bone discontinuity takes place through the induction of the piezoelectric effect in the connective structures improving the local circulatory conditions Pseudoarthrosis Magnetic fields have been shown to be effective in treating pseudoarthrosis Sudeck s disease and osteoporosis Magnetic therapy was effective in 8096 of cases with the Sudeck s disease and in 70 of osteoporosis Inflammatory and degenerative arthropathy Both inflammatory and degenerative arthropathies are treated by magnetic therapy Positive results have been obtained for rheumatoid arthritis in hands and knees spondylitis ankylopoetica gonarthrosis and lumbar arthrosis Arteriopathy obliterans Magnetic fields are effective for vascular diseases through their influence on the blood flux and micro circle Bed sores With its bio stimulating effect the magnetic therapy can be used against such disease Several treatments are needed for the cure to be effective Psoriasis Psoriasis responds well to this therapy in 60 of the cases MAGNETOMED MAGNETOMED 8200 MA1333 only generator
5. The integrated memory card reader extends to its maximum the device potential by offering the following services possibility to use the memory card with new working protocols The possibility of creating specific cards for the customs where to record their treatment possibility of storing new working protocols Main application fields Orthopaedics Rehabilitation Sport Medicine Aesthetic Medicine SHOCK MED COMPACT SHOCK MED COMPACT SW1350 Shock Med Compact is designed to give to the pro fessional a radial shockwave device ideal for use in ambulatory or home activities and sports The compact desktop case holds the built in com pressor having up to 4 bars of power at the same time quiet and efficient with a maximum weight of about 6 kg excellent for portable use Indications Shockwave therapy is the best treatment for the chronic insertional tendinopathies characterised by poor vascularisation of the osteotendinous junction when the physiotherapeutic treatment infiltrations and laser therapy has proved inef fective These are the main pathologies treated with shockwaves Elbow epicondylitis epitrocleitis Shoulder insertional tendinopathies impingement e Knee patellar and goose s foot tendinopathies Pubis adductor tendinopathies pubalgy Ankle achilles tendinopathy calcaneal apophysis WINNING FEATURES Wide display
6. Beam divergence CRYSTAL YAG 1064 230 Vca 50 60 Hz 1096 280 VA 230 Vac 5 A T Graphic colour 8 Touch screen 25W 10 100 10 100 Continuous 0 30Hz Up to 99 minutes 1 32 200 4 Gb Trolley based 40 6 x 105 x 30 cm Nd Yag 25W 1064 nm 4 3 19 m Sog CRYSTAL YAG D 1064 230 50 60 Hz 10 75 230 Vac 5A T Graphic colour 8 Touch screen 10 100 10 100 Continuous 0 30Hz Up to 99 minutes 1 32 200 4 Gb SES Nd Yag 1064 4 2 20 Sog MONOPHASE DIPHASE SINC MONOPHASE SINC DIPHASE SHORT PERIOD LONG PERIOD RECTANGULAR EXPONENTIAL TRIANGULAR TRAEBERT RECTANGULAR FARADIC TRIANGULAR FARADIC MODULATED FARADIC TRIANGULAR NEODINAMIC NEODYNAMIC TENS S A R TENS RANDOM S A R AL TENS TENS BURST S A R BIPHASIC SA GALVANIC IONTOPHORESIS INTERRUPTED IONOPHORESIS KOTZ RUSSIAN CURRENTS INTERFERENT CLASSIC INTERFERENTIAL ISOPLANAR INTERFENTIAL VECTORIAL INTERFERENTIAL H WAVE MICROCURRENTS APS HIGH VOLTAGE HVPC NMES ELEKTRA THERAPIC 2000 THERAPIC 7000 THERAPIC 9000 MONOPHASE DIPHASE SINC MONOPHASE SINC DIPHASE SHORT PERIOD LONG PERIOD RECTANGULAR EXPONENTIAL TRIANGULAR TRAEBERT RECTANGULAR FARADIC TRIANGULAR FARADIC MODULATED FARADIC TRIANGULAR NEODINAMIC NEODYNAMIC TENS TENS S A R TENS RANDOM S A R AL TE
7. diameter and 30 cm large covered with imitation leather featuring exclusive MFC patented system which concentrates the lines of force inside the solenoid without external dispersion in conformity with d lgs 626 The 60 cm solenoid is installed on a tray with ball bearing system that slides over the entire length of the couch Identification of the north pole for correct orientation High tech couch in aluminium with electrical sliding system equipped with 1 highly sliding track and 1 solenoid with 60 cm diameter and 30 cm large 1 remote control Cable for the cylinder 3 shelf trolley Pack of 10 patient smart cards Transport bag in tnt fabric i CONT72 MAGNETOMED MAGNETOMED 2000 e e e e e e e e e e e e 9 39 9 451 ACC1268 1 ACC1268 ACC1280 1 ACC1280 Resistiveelectrodes Capacitive electrodes ACC1310 ACC1309 Li eng ml 1506 2 ACC606 ACC1317 2 E ACC604 OPTIONAL ACCESSORIES HR DESK BASIC ACC1268 1 Applicator for resistive electrodes with power regulation e ACC1268 Applicator for capacitive electrodes with power regulation 1280 1 Applicator for capacitive electrodes e ACC1280 Applicator for resistive electrodes e ACC1268 3 Resistive electrode 30 mm e 1268 5 Resistive electrode 0 50 mm 1268 7 Resistive electrode 70 mm 1268 8 Resistive electrode 80 mm e e e ACC1307 3 Ca
8. 1 15 Hz max Graphic colour LCD 6 Touch Screen 0 2 millions rounds 20 200 200 8 kg 39 175 28 cm DESK 230 50 60 Hz 10 230 Vea 3 15 5x20 mm Graphic colour 320 x 340 pixel Touch Screen until 30 minutes 455 Khz 10 Max 250 Watt 2 n 1 output capacitive use 1 output resistive use 2 n4 for capacitive use n 1 for resistive use 48 200 4 Gb 39x28x18 cm 9 5 Kg HR TEK BASIC 230 Vca 50 60 Hz 10 230 Vca 3 15 A T 5x20 mm Graphic colour 320 x 340 pixel Touch Screen until 30 minutes 455 Khz 10 Max 200 Watt II B 2 nioutput capacitive use n 1 output resistive use 2 without adjustment of power n 1 capacitive n 1 resistive 20 200 200 39x28x18 cm 9 5 Kg ND YAG LASERTHERAPY MODELS Power supply Maximum main power absorption Double delay type T mains Backlit LCD display to view and check the operating parameters Peak power in continuous mode Pulse adjustable Setting emission Emission Emission frequency Classification according to Directive 93 42 EEC Insulation class parts applied in accordance with EN 60601 1 Adjustable treatment time Output channels Stored protocols Storable programs on the internal memory Storable programs on the USB Size FEATURES LASER SOURCE Source type Peak power in continuous mode Wavelength Laser Class according to EN 60825 DNRO m
9. 12W Probe with optical fibre 1 Laser protective goggles User manual in DVD USB Key Power cable Fuses Interlock Optional accessories gt pg 61 Technical specifications gt pg 73 _ SUPPLIED WAVEFORMS Galvanic continuous interrupted MF Dyadinamic monophasic Biphasic monophasic sync Biphasic sync CP LP Pulse rectangular triangular traebert Faradic rectangular triangular neodynamic e Tens burst random modulated al tens Biphasic symmetric asymmetric Interferential quadripolar Isoplanar vector bipolar Stimulating Russian current kotz Micro currents High Voltage HVPC H Wave APS Creation of rheobase and cronaxie curve The main fields of application are Paintreatment chronic pain post surgical acute pain Orthopedics tendinitis arthritis epicondylitis etc Sport Medicine sprains muscle aches etc Aesthetics PEFS lymphatic drainage etc Dermatology keloids lymphedema bedsores etc Neurology neuralgia phantom limb pain etc Uro gynecology urinary incontinence ELEKTRA Available models ELEKTRA 2 EK1302 ELEKTRA 2 EK1302 OPERATING MODE AND BENEFITS The new electrotherapy device EleKtra gives access to currents and programs by different screenshots you can select from list of waveforms treatment protocols or various applications according to every body part You can use the same programs in
10. ACC916 Vacuum sponges 90 mm 4 pcs e ACC696 Vacuum output cable e ACC697 Link cable for combined use of vacuum electrotherapy e ACC699 Short output cable 20 cm e ACC604 3 shelf trolley e MARKETING SCIENTIFIC LITERATURE 01 Manuale clinico di terapia fisica by Dr Aldo Vasta Italian version 5 copies 2 Clinical Manual of physical therapy by Dr Aldo Vasta English version 5 copies Stimolazione elettrica neuromuscolare by Dr Aldo Vasta Italian version 5 copies POSTER ACCM16 POSTER ELEKTRA KSOUND ACCM17 POSTER MAGNETOMED ACCM18 POSTER RADARMED ACCM19 POSTER SHOCKWAVE ACCM20 POSTER HR TEK ACCM21 POSTER PR 999 ACCM22 POSTER VIKARE BIPOWERLUX 2 POSTER PRESSOMED TECHNICAL SPECIFICATIONS MODELS Power supply Maximum main power absorption Fuses Backlit LCD display to view and check the operating parameters Adjustable treatment time Operation frequency Isolation class Risk class 93 42 CEE Degree of protectioni from liquids Probe Output channels Peak power in continuous mode Peak power in pulsed mode Duty cycle Stored protocols Storable programs on the internal memory Storable programs on the Smart Card Storable programs on the USB Automatic contact sensor Automatic probe recognition Low BNR selfcalibrating probe Water resistant probe Possibility to update the software External connection Weight Size ULTRASON
11. BF Type IPXO 50 50 4kg 39 x 14 x 30 cm RADAR THERAPY MODELS Power supply Maximum main power absorption Double delay type T mains Backlit LCD display to view and check the operating parameters Adjustable treatment time Pulsed peak power on 50 Ohm load Continuous peak power on 50 Ohm load Isolation class Risk class 93 42 CEE Degree of protection from liquids Stored protocols Storable procotols on the Smart Card Storable programs on the internal memory Alarm in case of overheating Diagnostic test to check the unit function Low noise fans Weight Size RADARMED 2500 CP 230 Vca 50 60 Hz 10 650 VA 6 3 A T Graphic colour 320x240 Pixel Touch 8 Scrool 1 30 minutes 1600 W 250 W BF Type IPXO 100 200 200 40 Kg 39 x 89 x 30 cm RT 250 DIGITAL 230 50 60 Hz 10 650 VA 6 3 A T Graphic bw 240x128 Pixel 1 30 minutes 1600 W 250 W BF Type IIB IPXO 50 50 40 Kg 39 x 89 x 30 cm MODELS Power supply Maximum main power absorption Double delay type T main fuses Backlit LCD display to view and check the operating parameters Maximum power Configuration of the laser probe Emission wavelength laser diode Laser Classification Emission frequency Pulsed mode Classification according to Directive 93 42 EEC Output channels Insulation class parts applied in accordance with EN 60
12. Fuses 2 da 315mA T Electrodes 60x85 mm 4 Sponges for Electrodes 60x85 mm Electrodes 50x50 mm Sponges for Electrodes 50x50 mm Elastic band 1000 mm Elastic band 600 mm Electrotherapy Output cable Optional accessories gt pg 59 Technical specifications gt pg 67 i r hi n 0550 0550 is a desktop equipment for ultrasound therapy with 1 output supplied with 1 3 Mhz multifrequency probe _ MAIN EFFECTS OF ULTRASOUND The ultrasound therapy has an impact on the human tissues through a high frequency cellular and intercellular level massage The tissues irradiated by ultrasounds start vibrating with a resulting waste of energy and generation of heat The effects are then summarized as follows MECHANICAL EFFECT Expands through the rhytmic tissue compression and decompression THE DIATHERMIC MECHANISM While the sound spreads through the tissues it is absorbed and converted into heat CHEMICAL EFFECT It is strictly connected to a typical phenomenon caused by ultrasounds the so called cavitation which takes place in the fluid components of the tis sues where the small gas bubbles tend to increase their dimension and starts the oxidation polymeriza tion and the destruction of macromolecules NEURAL EFFECT It is linked to ultrasound s influence on the neu rovegetative system a US 50 New Design Medical Italia 1 3 Mhz Multifrequency probe Possible co
13. at the same time Smart Card ULTRASONIC ULTRASONIC 2500 ts US1323 e two independent channels ultrasound device on trolley equipped with two 1 3 MHz probe and with one orthostatic arm ULTRASONIC The ultrasounds are high frequency acoustic vibrations not perceived by human ears The application of ultra sounds for therapeutical use on human tissues involves a high frequency cellular and intercellular massage More over ultrasounds can also be used in immersion the head is immersed in the water together with the body region to be treated The tissues irradiated with ultrasounds start vibrating with a following energy waste and heat production All this shows the ultrasounds biological ef fects namely the mechanical and the diathermic effect Mechanical effect expands through the rhythmic tissue compression and decompression The tissue particles re ceiving the vibrating flux are all stressed one after the other at the same speed and acceleration rate SUPPLIED ACCESSORIES ULTRASONIC 1300 Power cable 1 User Manual in DVD 1 Fuses 2 of 630mA T Probe 1 3 MHz 5 cm 1 Orthostatic arm Smart Card Optional accessories pg 58 Technical specifications gt pg 66 Available models ULTRASONIC 1300 ULTRASONIC 1500 ULTRASONIC 2500 e Diathermic mechanism probably with biological effects is becoming possible with watt cme energy flux While the sound spreads through the tissues
14. of probes available mono multi diodic probes up to 800 mW LASER THERAPY ADVANTAGES Smart Card Laser therapy is based on photochemical and photobiological effects on the cells and on the tissues The laser beam stimulates the mitochondria of the cell restores its energy and protects it in case of traumatic or degenerative situations restoring the normality of the cell itself Laser therapy is painless has no risks and is not invasive The suggested time for a treatment is inferior to the one of other therapies SUPPLIED ACCESSORIES LASERMED LASERMED EFFECTS OF LASER 2100 2200 Power cable 1 1 Anti inflammatory effect User Manual in DVD 1 1 Effects the peripheral nervous system Fuses 20f315A T 20f63A T antalgic and regenerative effect Laser probe MLA1 25 mW 1 Biostimulating tissue regenerating effect Laser protection goggles 2 2 x Effect on the micro circulation and on the blood Interlock safety key 1 1 veins the laser entails an enhancement of the Smart Card 1 1 local microcirculation that includes the relief of local spasms of arteries and veins that take place for example after a trauma or an inflammation determines an intensification of the blood flow within the nutritional capillaries IMmunoregular effect Enzymatic photoactivation effect Placebo effect Optional accessories pg 63 Technical specifications gt pg 70 PR999 4W 2W 2W SL1366 Two wavelen
15. of traumatology and orthopedics of the Academy of medical sciences of Ukraine Kiev Medical Center of Rehabilitation of railwaymen of PZZ Hmil nik DM Electronic Medical Equipment 38 EME Health amp Beauty Technology 62 A UNIQUE PERFORMANCE The new Elekta line by Medical Italia was created to meet the needs of professionals in the sector they are ever more looking for innovation and for products that can improve the results of their work and simplify their tasks The EleKta line support the professionals in their work guiding them step by step to deliver the best treatment while providing on display useful information on it ELEKTA LINE SHOCK MED BIPOWER LUX UT ur Be ELEKTRA Pe AS l F CRYSTAL YAG K SOUND a 1 kt NEW GENERATION TECHNOLOGY Shockwaves are acoustic waves that deliver high energy They pass through the skin surface and spread in a radial way through the body in the painful area Shock Med delivers radial ballistic shockwaves The shockwave is generated in a spe cial gun shaped applicator a steel bullet is shot against a metallic lid inside the barrel of the appli cator by means of compressed air pressure up to 5 bar This process generates a shockwave that spreads in a radial way through the skin and the first tissue layer under it or in a focused way depending on the transmitter used The body responds by incre
16. the first treatment Deep action on tissues High biostimulating effect Awinning combination that makes patients fully satisfied with the treatment SUPPLIED ACCESSORIES CRYSTALYAG CRYSTAL YAG DESK Defocused laser probe detachable 1 Defocused laser probe incorporated with the device Laser protective goggles USB Key User manual in DVD Power cable Fuses Optional accessories pg 61 Technical specifications gt pg 75 The application fields where you can get great benefits by delivering Bipower Lux laser therapy are the following SPORT TRAUMATOLOGY Muscle strains and extensions Articular distorsions Epicondylitis Tendinitis and enthesitis Contusions hematomas and bruises Bursitis GENERAL MEDICINE AND DERMATOLOGY Decubitus ulcers cheloids torpid sores treated thanks to its well known biostimulating and anti infective effects ARTHRO RHEUMATIC PATHOLOGIES Arthrosis Sciatica Scapular humeral perarthritis Arthropathies of hands and feet Epicondylitis Hip arthrosis in the early stage Gonalgia with or without effusion Myogenic stiff neck Lumbago Myositis etc REHABILITATIVE THERAPY Articular motor rehabilitation after removing plaster casts or after orthopaedic surgical operations BIPOWER LUX Available models BIPOWER LUX 6W BIPOWER LUX 12W BIPOWER LUX 6W HL1362 6 BIPOWER LUX 12W HL1362 12 _ THE EVOLUTION OF L
17. 0 ACC715 LC60E ACC668 ACC604 ACC606 CONT72 Portable cylinder with 30cm diameter for the treatment of lower and upper limbs equipped with feet for standing on flat surfaces with exclusive MFC patented system which concentrates the lines of force inside the solenoid without external dispersion in conformity with d 195 626 Identification of the north pole for cor rect orientation Portable cylinder with 50cm diameter for the treatment of lower and upper limbs equipped with feet for standing on flat surfaces with exclusive MFC patented system which concentrates the lines of force inside the solenoid without external dispersion in conformity with 195 626 Identification of the north pole for correct orientation Pair of applicators sized 16 x 10 x 3 5 cm for localised treatments The applicators can work side by side to treat wide areas or one opposed to the other to concentrate magnetic induction in a limited area Light weight and reduced heat sensation during the treatment High tech couch in aluminium with 2 highly sliding tracks and 2 cylinders with 60 cm diameter and 30 cm large covered with imitation leather featuring exclusive MFC patented system which concentrates the lines of force inside the solenoid without external dispersion in conformity with d 195 626 Identification of the north pole for correct orientation High tech couch in aluminium with 1 highly sliding track and 1 cylinder with 60 cm
18. 08 and ISO 13485 2004 Each piece of equipment is supplied with a testing cer tificate in compliance with current regulations Furthermore all medical devices comply with European regulations and they are marked CE0476 directive 93 42 THE DIVISIONS OF EME GROUP _ SOULS IN ONE HEART EME created 5 divisions in order to concentrate and optimise the company resources in each product sector Each division has a dedicated workgroup which aims at offering ever innovative solutions and high tech devices in line with corporate values and AN mission d 27 MEDICAL ITALIA Physiotherapy amp Rehabilitation Division _ MEDICAL ITALIA Division for designing and producing physical therapy and rehabilitation devices Medical Italia offers a whole range of devices for physical therapy with dif ferent options to meet the different needs of the final users A high quality brand for reliable and easy to use devices TECNOLOGIE MEDICHE Aesthetic Medicine Division _ TECNOLOGIE MEDICHE Division for designing and producing aesthetic medi cine devices EME s quality and experience in the med ical sector is meant for those who work in the field of aesthetic medicine The medical devices are in compliance with the directives 93 42 EEC CE 0476 mark and are designed and produced taking into account the needs of the doctors ESTETIC ITALIA Division for designing and producin
19. 4 ACC605 BO U op Los pm call ACC606 ACC601 ACC603 8 CONT72 ACC604 ACC1317 2 E OPTIONAL ACCESSORIES K SOUND ULTRASONIC COMBIMED COMBIMED US 50 200 2200 ACC940 TV5 ultrasound probe 1 3 mhz emitting area 5 ACC940 1 TV1 ultrasound probe 1 3 mhz emitting area 1 cm 940 3 ultrasound probe 1 mhz emitting area 3 cm e e ACC940 8 TV8 ultrasound probe 1 mhz emitting area 8 cm e e ACC943 TV5 ultrasound probe 1 mhz emitting area 5 cm e ACC943 1 TV1 ultrasound probe 1 mhz emitting area 1 cm e ACC943 3 TV3 ultrasound probe 1 3 mhz emitting area 3 cm ACC943 8 TV8 ultrasound probe 1 mhz emitting area 8 cm e ACC939 2 TV5 ultrasound probe 2 mhz emitting area 5 cm 939 6 TV1 ultrasound probe 2 mhz emitting area 1 ACC939 7 TV3 ultrasound probe 2 mhz emitting area 3 cm e ACC939 9 TV8 ultrasound probe 2 mhz emitting area 8 e ACC666 1 Ultrasound probe with integrated water bolus kit gel holder 917 Gel 260 ml e ACC918 Gel 1000 ml e e 919 Gel canister 5000 ml ACC400 1 Conductive rubber electrode 80 x 120 mm e e ACC403 Conductive rubber electrode 60 x 85 mm e e ACC402 Conductive rubber electrode 50 x 50 mm e 401 Sponge electrode cover 80 x 120 mm Sponge electrode cover 60 x 85 mm 001 Sponge electrode co
20. 40x128 Pixel 905 nm 1 99 minutes 200 10 000 Hz 100 nsec 10 10096 1 Type IIB 3B 50 50 4kg 39 x 14 30 TECHNICAL SPECIFICATIONS MODELS Power supply Fuses Backlit LCD display to view and check the operating parameters Adjustable treatment time Adjustable treatment frequency Maximum induction Isolation class Risk class 93 42 CEE Degree of protection from liquids MFC patent that reduces electromagnetic pollution by more than 85 Output channels Stored protocols Storable procotols on the internal memory Storable programs on the Smart Card Power greater than 400 Gauss Possibility to manage solenoids in various shapes and sizes Protection from electric short circuit Adjustable Duty cycle from 10 a 100 Weight Size MAGNETOMED 7200 8200 230 Vca 50 60 Hz 10 2 x 3 15A T Graphic colour 320x240 Pixel Touch amp scrool 1 99 minutes 1 100 Hz 100 Gauss 20 BF Type IIA IPXO 100 200 200 7200 3 5 Kg 8200 27 Kg 7200 39 x 14 x 30 cm 8200 39 x 89 x 30 MAGNETOMED 8400 230 Vca 50 60 Hz x 1096 2 x 6 3A T Graphic colour 320x240 Pixel Touch amp scrool 1 99 minutes 1 100 Hz 100 Gauss 20 BF Type IPXO 4 indipendenti 100 200 200 27 Kg 39 x 89 x 30 cm MAGNETOMED 2000 230 Vca 50 60 Hz 10 2x 3 15A T Graphic bw 240x128 Pixel 1 99 minutes 1 100 Hz 100 Gauss 20
21. 6 colour touch screen Procedure function A practical and handy application manual of the shockwave therapy based on four fundamental steps Localise the painful area by touch Select the therapy parameters manually or using preset programs Apply gel Start the shockwave therapy More than 40 therapeutic suggestions grouped according to anatomical areas specialist branches Patient file for storing all patient s data treatments and short case history Help button Each therapeutic suggestion shows indications on its use One Touch mode by pressing just once the activation button the procedure will start and continue until the end of the therapy or until the operator will press again the button to pause the execution of the treatment Soft Rebound System rebounding to the therapist s arms was reduced by 9596 thanks to the new applicator developed by EME which has an internal spring system to dampen the rebound effect Smart Card to store many personalised treatments and patient files SUPPLIED ACCESSORIES SHOCK MED COMPACT applicator 1 Power cable 9 mm multifocused transmitter 9 mm focused transmitter 15 mm multifocused transmitter Fuses Gel 260 ml User manual in DVD Smart Card PPPNMNPRPRPRP Optional accessories gt pg 62 Technical specifications gt pg 74 The main fields of application are Dermatological diseases Traumatology
22. 601 1 Stored protocols Storable programs on the internal memory Storable programs on the Smart Card Storable programs on the USB Weight Transportable desktop container Size VIKARE 4W 230 Vea 50 60 Hz 10 70 VA 230 Vac 630 mA T 5x20 mm Graphic colour LCD 6 Touch screen 4W Integral connection with the machine 940 nm 4 zio 100 Hz 10000 Hz 10 100 IIB 5 32 200 200 4 65 Kg 39X179 281CM TECHNICAL SPECIFICATIONS VIKARE 8W 230 50 60 Hz 10 70 VA 230 Vac 630 mA T 5x20 mm Graphic colour LCD 6 Touch screen 8W Integral connection with the machine 940 nm 4 1721 100 Hz 10000 Hz 1096 10096 32 200 200 4 65 Kg 39 x 1 5 x 28cm BIPOWER LUX 6W 230 50 60 Hz 10 75 230 Vac 630 mA T 5x20 mm Graphic colour LCD 8 Touch screen 6W Integral connection with the machine 810 980 nm 4 2 100 100 Hz 10000 Hz 1096 10096 00 4 Gb 4 90 Kg 39 175 x28 BIPOWER LUX 12W 230 50 60 Hz 10 75 VA 230 Vac 630 5 20 mm Graphic colour LCD 8 Touch screen 12W Integral connection with the machine 810 980 nm 4 2 986 100 Hz 10000 Hz 10 100 IIB 32 200 4 Gb 4 90 Kg 39 1 5 x28 74 MODELS Power supply Maximum mains power absorption Maximum compressor absorption Fre
23. 62 OPTIONAL ACCESSORIES POLYTER 6 POLYTER 10 ELECTROTHERAPY ACC400 1 Conductive rubber electrode 80 x 120 mm e e ACC403 Conductive rubber electrode 60 x 85 mm e e ACC402 Conductive rubber electrode 50 x 50 mm e 401 Sponge electrode cover 80 x 120 mm Sponge electrode cover 60 x 85 mm 001 Sponge electrode cover 50 x 50 mm e e ACC28 Stretch bandage 1000 x 50 mm ACC27 Stretch bandage 600 x 50 mm e e ACC306 Self adhesive electrodes 45 x 35 mm e e ACC305 Self adhesive electrodes 45 x 80 mm e e ACC905 Self adhesive electrodes 46 x 47 mm e 906 Self adhesive electrodes 53 x 96 mm e e ACC907 Self adhesive electrodes 46 x 98 mm e 909 Self adhesive electrodes 45 x 100 mm e e ACC910 Self adhesive round electrodes 32 mm e 911 Self adhesive round electrodes mm e e ACC912 Self adhesive round electrodes 75 mm ACC300 Electrotherapy output cable LASER THERAPY 559 Laser probe 25mw guide light e e EME laser protective goggles e ULTRASOUND THERAPY ACC528 1 Ultrasound probe 1 mhz 5 cm e 914 695 ACC913 ACC916 ACC621 915 gt n ACC696 ACC697 ACC699 ACC604 OPTIONAL ACCESSORIES VACUUMED ACC913 Vacuum cups 30 mm 2 pcs e ACC695 Vacuum cups 60 mm 2 pcs e 914 Vacuum cups 90 2 pcs e ACC915 Vacuum sponges 30 mm 4 pcs e ACC621 Vacuum sponges 4 60 mm 4 pcs e
24. E WINNING LASER FOR THE MOST DEMANDING PROFESSIONALS IT IS POWERFUL Due to the high power output of the two models it makes possible the stimulation of the deep layers of the treated tissue and thus favors a rapid and wide spread cell regeneration ViKare allows a deep tissue stimulation and this allows to treat the internal struc tures such as the articulation of the femur and chronic conditions such as osteoarthritis _ SAFE AND EASY TO USE ViKare is controlled by a software that can be used by all operators with intuitive controls for quick and easy implementation It is designed to ensure the highest safety standards Maximun attention is paid to the safety of the patient and the operator POLYHEDRIC Thanks to its characteristics ViKare can be used in various branches such as sports medicine orthopaedics neurology dermatology rheumatology dentistry conservative periodontics implantology oral pathology surgery scaling and acupuncture EFFECTIVE Definitive in acute inflammation chronic and degenera tive diseases such as arthritis of the knee _ MULTISPOT ViKare automatically calculates the energy dose fluence in joules delivered according to different methods of application contact or through the 3 spacers available WHY TO CHOOSE VIKARE ViKare is designed as power laser that operates with a single wavelength 940 nm Making the most of the peak power from the two available models you can p
25. Easy to use friendly user interface Color display with Touch amp scroll Up to 100 therapeutic suggestions Adjustable power up to 100 Gauss per each channel Multilanguage software Smart Card n 1 cs ACC551 1 LC60 2 High tech bed with 2 solenoids for total body treatment SUPPLIED ACESSORIES MAGNETOMED 7200 8200 8400 Power cable 1 User Manual in DVD 1 Fuses 2 da 15 Magnetic testing ring 1 Smart Card 1 Optional accessories 60 Technical specifications gt pg 71 ACC536 GC9 kit point for the treatment of inferior limbs Fields of application Dermatologic diseases Traumatology Sport Medicine Aesthetic Medicine PRESSOMED 2900 PRESSOMED 2900 PR1380 Pressure therapy is a therapeutic massage which helps fighting edemas and improves blood circula tion thanks to the application of a pressure This pressure is applied in a sequential order to treat the inferior limbs suffering from edema water retention and circulatory problems Pressure therapy acts on blood and lymphatic circulation helping it be more efficient and improving aesthetic blemishes such as cellulite water reten tion etc _ THERAPEUTIC ACTIONS Circulatory insufficiency lymphatic stasis Hydro lipodystrophy cellulite Lymphedema Reactive cutaneous fibrosis Hard edema Post operative troubles Hypotonia PRESSOMED JUST THE BEST FOR O
26. Eh tag lt Local Association Heliopolis Rashdeen Cairo Local Association in Menoufiay Governorate Kader Factory Medical Center Military Forces Cairo Ministry of Health Port Said City Ministry of Health Ismailia City Hanin Medical Center Suez City El Zeiny Medical Center Alexandria Red Cresent Association Kalioubia City Sedky Medical Center Cairo Ministry of Health Shoubra City Bagedo Hospital Jeddah K S A Hospital Riyadh University Hashemite Amman UNRWA Amman Laro Medical center Beirut Physical therapy and Rehab center Manama German orthopaedic Centre Muscat Imanuel Hospital at Bandar Lampung Harapan Bunda Hospital at Jakarta Permata Hospital at Jakarta Retna Clinic at Jakarta A E rad cca gt a e Aet D Ms WIE k om MT Las E ia Pantai Hospital Kuala Lampur Maternity Hospital of the Minsk region Republic Center for Medical Rehabilitation and Balneotherapy Minsk Medical hospital Neurospine Baku Medical center Tebriz Baku Farab Sanatorium Farab Republic Scientific Center of Neurosurgery of the Ministry of Healthcare of the Republic of Kazakhstan Astana FGBU Scientific Research Institute of Cardiology Tomsk Altamedika Moscow FMBA Hospital Ne 85 Moscow FMBA Hospital Ne86 Moscow GUVD Police Hospital Moscow MVD Police Hospital Moscow Medical Center Samara Institute
27. IC 1300 230 50 60 Hz 10 40 VA 2 x 630 mA T Graphic colour 320x240 Pixel Touch 8 Scrool 1 30 minutes 1 3 MHz BF Type IB IPXO IPX4 1 2 W cm 20 3 W 2096 1096 10096 100 200 200 39 x 14 x 30 cm ULTRASONIC 1500 2500 230 50 60 Hz 10 70 VA 2 x 630 mA T Graphic colour 320x240 Pixel Touch 8 Scrool 1 30 minutes 1 3 MHz BF Type IIB IPX4 2 independent 2W cm 20 3 W cm 20 10 100 100 200 200 3 6 Kg 2500 26 Kg 1500 39 x 14 x 30 cm 2500 39 x 89 x 30 cm US50 230 Vca 50 60 Hz 10 40 VA 2 x 630 mA T Graphic bw 240x128 Pixel 1 30 minutes 1 3 MHz BF Type IPX4 1 2 W 20 cm 20 10 100 50 50 1500 4 39 x 14 x 30 cm K SOUND 230 Vca 50 60 Hz 10 40 VA 2 x 630 mA T Graphic colour 8 Touch screen 1 30 minutes 1 2 3 MHz BF Type IIB IPXO IPX4 2 indipendent 2 W 20 20 1096 10096 100 250 4 Gb 36Kg 3 6Kg 39 x 14 x 30 cm MODELS Power supply Maximum main power absorption Double delayed type T mains fuse protection Backlit LCD display to view and check the operating parameters Adjustable treatment time Operation Risk class 93 42 CEE Creation of the Rheobase and Chronaxie intensity Time curvea Interferential currents Current high voltage Micro cu
28. IGHT The new range of high power lasers uses optical fibre to convey high laser powers 6W 12W directly to the skin without dispersions Bipower Lux treats effectively inflammatory and degenerative pathologies of the or thopaedic neurologic dermatologic fields and reduces the recovery time Bipower Lux has become an essen tial treatment especially for the sport medicine as it allows a fast recovery time and the healing of many sportsmen for whom time is a key factor in their career HIGH ENERGETIC IMPACT WITH DUAL WAVELENGTH Bipower Lux combines 2 wavelengths 810 980 nm and gets the best of their main therapeutic actions 810nm wavelength has a high depth of penetration in the tissues and gives an excellent biostimulating effect 980nm wavelength has a high level of absorption in the fluids and provides a high analgesic effect Bipower Lux is recommended for superficial patholo gies in general medicine and dermatology and for orthopaedic and sport medicine pathologies contu sions bursitis tendinitis etc It has a high biostimu lating effect because it covers the whole therapeutic window of high power therapeutic lasers HPLS gt high power laser system with a very high output power up to 12W BIPOWER LUX LUNGHEZZA D ONDA WAVELENGHT nm 200 300 400 500 600 700 810 2900 980 1100 1200 1300 1400 10600 Epidermide Epidermis i Osso Bone SUPPLIED ACCESSORIES BIPOWER LUX 6
29. MEDICAL ITALIA TOP QUALITY PHYSIO CONCEPT ELECTRONIC EQUIPMENT FOR PHYSIOTHERAPY SPORT MEDICINE AND REHABILITATION Medical Equipment EME ELECTROTHERAPY VACUUM THERAPY ULTRASOUNDS COMBINED DEVICES MAGNETIC THERAPY PRESSURE THERAPY RADAR THERAPY SHOCK WAVES LASER THERAPY ENDODIATHERMY HIGH POWER LASER Electronic Medical Equipment Seeccsesce 2882082209000000000 228928960060000000 se0ssssessoseo cossssscessesseseone 2442222 28822222 2222820220200 H H H H H H H H H H TECHNICAL SPECIFICATIONS AND ACCESSORIES EME THE GROUP Pg 4 REFERENCES Pg 8 ELEKTA LINE SWT SHOCK MED Pg 12 Pg 14 CRYSTAL YAG Pg 16 BIPOWER LUX Pg 18 ELEKTRA Pg 20 K SOUND Pg 22 PRESTIGE LINE SHOCK MED COMPACT Pg 26 HR TEK BASIC Pg 28 VIKARE Pg 30 THERAPIC Pg 32 ULTRASONIC Pg 34 COMBIMED 2200 Pg 36 VACUUMED Pg 37 LASERMED Pg 38 PR999 Pg 40 RADARMED 2500 CP Pg 42 MAGNETOMED Pg 44 PRESSOMED 2900 Pg 46 BUSINESS LINE THERAPIC 2000 Pg 50 US 50 Pg 51 COMBIMED 200 Pg 52 POLYTER 6 10 Pg 53 LIS 1050 Pg 54 MAGNETOMED 2000 Pg 55 RT250 DIGITAL Pg 56 ACCESSORIES TECHNICAL SPECIFICATIONS SUPPLIED WAVEF
30. NS TENS BURST S A R BIPHASIC SA GALVANIC IONTOPHORESIS INTERRUPTED IONOPHORESIS KOTZ RUSSIAN CURRENTS INTERFERENT CLASSIC INTERFERENTIAL ISOPLANAR INTERFENTIAL VECTORIAL INTERFERENTIAL H WAVE MICROCURRENTS APS HIGH VOLTAGE HVPC COMBIMED 2200 200 POLYTER 6 POLYTER 10 Oses E La EME srl si riserva la facolt di apportare modifiche al materiale divulgato ed alla gamma dei prodotti senza obbligo di preavviso EME s rl should modify or change the information contained in this catalogue without obligation of notice Le immagini riprodotte nel presente catalogo hanno fine indicativo e non esplicativo Per il corretto utilizzo delle apparecchiature attenersi ai relativi manuali d uso The pictures contained in this cataloghe do not describe the use of the devices For a correct use of the devices please refer only to the user s manual ESTETIC ITALIA aesthetics division EME SRL YOUR IDEAL PARTNER ALSO FOR AESTHETICS AND AESTHETIC MEDICINE EQUIPMENT ith w TECNOLOGIE MEDICHE Aesthetic Medicine Division MEDICAL ITALIA Physiotherapy amp Rehabilitation Division i Italia EME Divisione di sr Via degli Abati BB GILES Pesaro PL 5 Beauty Technology boi 39 OTELA DOTI fux 39 ELS wewera sricom nfofome pricom GOOSE
31. ORMS Pg Pg Pg 58 66 76 EME THE GROUP EVERYONE EVERYWHERE EVERY TIME EME was created in 1983 since then EME has become an industrial group thanks to the experience of profes sionals in the fields of production and technological in novation The new lines of safe and reliable equipment for Physiotherapy Aesthetics and Aesthetic Medicine have allowed EME to successfully develop its offer in 60 countries around the world with a production proudly marked Made in Italy EME has created 5 divisions in order to concentrate and optimise the company re sources in each product sector Each product follows the vision of EME we offer quality innovative solutions and high tech devices for everybody everywhere every time _ STRONG CORPORATE IDENTITY Since its birth EME has been updating the vision that guides its development and values in support of its ac tions The aim has always been to focus on the creative and production energies to create a unique and strong corporate identity EME has been true to its values and has applied this very practical and participative ap proach by investing since the beginning in resources of technological innovation to create a range of cutting edge products Our real estate is not just the industrial property but also the intellectual assets of men who have been working with us for over 30 years Research and development are two pillars of EME MISSION Our Mission is to pr
32. Sports Medicine Aesthetic Medicine Musculoskeletal pain Inflammatory joint and tendon Periarticular disorders bursitis calcification etc HR TEK BASIC _ LET THE WARMTH HEAL YOU Color graphic display with 320 x 240 pixels Output power up to 200W Smart Card to store many personalised treatments and patient files Meter of the real treatment time by the new contact detection system i Wi j De T 1 1 LO Impedance meter displaying real time values HR TEK BASIC HT1342 HR TEK Basic is the new capacitive and resistive en dodiathermy desktop device designed for the most demanding professionals HR TEK Basic is the answer to those who want a device that can be used for out patient treatment compact lightweight and func tional and for ambulatory use too 5 AND OPERATING MODE CAPACITIVE The action is concentrated in the area below the movable electrode works actively on soft tissue rich in water content such as muscles venous lymphatic etc it achieves ex cellent results in applications such as after fractures treatment joints and periarticular diseases drainage of post traumatic oedema RESISTIVE it carries out an effective action on tis SUPPLIED ACCESSORIES HR TEK BASIC sues with the highest resistance having low water 1 content The biological effect occurs tissues with User Manual in DVD 1 the highest
33. TIC THERAPY 1 output for magnetic therapy Maximum power 100 Gauss ULTRASOUND On request 1 output e IMHz continuous mode LASER On request 1 output 905mm SUPPLIED ACCESSORIES POLYTER6 POLYTER 10 Power cable 1 1 User Manual 1 1 Fuses 2 x630 2 630 Electrodes 60x85 mm 2 4 Electrodes 50x50 mm Sponges for Electrodes 60x85 mm Sponges for Electrodes 50x50 mm Elastic band 1000 mm Elastic band 600 mm Couple of circular applicators for magnetic therapy 1 Electrotherapy Output cable 1 On request you can add accessories for laser therapy and ultrasound to have the complete device ACC528 1 1 Mhz ultrasound probe 5 ACC559 25 mW laser probe Optional accessories gt pg 64 Technical specifications gt pg 69 LIS 1050 LIS 1050 e Laser therapy device with 1 output Wavelength 905 nm LASER THERAPY Laser therapy uses the effects of energy generated from laser sources Light Amplification by Stimulated Emission of Radiation The laser beam enters into the tissues and causes a biochemical response on the cell membrane and inside the mitochondria _ MAIN EFFECTS OF LASER Anti inflammatory effect due to increased blood flow as result of vasodilatation Anti edema action many inflammation are accompanied by edemas is due to the change of the hydrostatic intercapillary pressure Analgesic Action due to the increase of the threshold of perception of the nerve e
34. The electric currents pass through the body s area through the various waveforms that are selected according to the treatment s purpose _ ANALGESIC EFFECT The treatments with analgesic effects are among the most used in physiotherapy and the currents that reach this result are as follows Tens Diadynamic Interference lontophoresis Continuos current used to introduce drugs into the body STIMULATING EFFECT Electrotherapy stimulation means to provide a muscle induced contraction by applying electrodes on the muscle The goal is to reduce the wasting due to the non use of norm innervated muscle muscle that contracts voluntarily and enhance the denervated muscle muscle that does not contract voluntarily The different waveforms to be used must be selected according to the therapeutic program and to the characteristics of the muscle to be contracted WHY THERAPIC 2000 New Design Medical Italia 23 waveforms available in the software Two completely independent outputs with banana cables 2 mm Possible connection to ultrasound model US50 US1320 for combined applications Graphic display with a very good resolution Easy to use very easy and clear interface Possible connection to the Vacuum model Vacuumed VU1392 for combined applications Electrodes test Multilingual software 50 Therapeutic suggestions SUPPLIED ACCESSORIES Power cable User Manual in DVD
35. UR PRO 9 completely independent sectors Maximum pressure 150 mm Hg for each sector High quality kit points with herringbone pattern sectors Independent pressure adjustment for each sector Latex blister independently replaceable Kit point damage control Graphical display representation of the massage More than 20 available protocols ACC334 GC9 S kit point for the treatment of inferior limbs with separate foot sector SUPPLIED ACCESSORIES PRESSOMED 2900 Power cable 1 User Manual in DVD 1 Fuses 2 da 1 6 A T Smart Card 1 Optional accessories gt pg 62 Technical specifications gt pg 69 FAST AND EASY SOLUTION BUSINESS LINE 3 N THERAPIC 2000 LIS 1050 lt p US 50 77 RT250 DIGITAL 1 COMBIMED 200 MAGNETOMED 2000 POLYTER THERAPEUTIC SUGGESTIONS The new software has inside about 50 certified working protocols INTERNAL MEMORY All the equipments are also provided with an internal memory with the possibility of customizing up to 50 protocols ENCODER Encoder was added to facilitate the selection of the various parameters inside the equipment THERAPIC 2000 1 i aE THERAPIC 2000 Electrotherapic device with 2 independent channels lending currents at low and medium frequency _ MAIN EFFECTS Biological effects obtained by electrical energy are used for therapeutic purposes with success
36. ally in chronic diseases 50 therapeutic suggestions SUPPLIED ACCESSORIES COMBIMED 200 Power cable 1 User Manual in DVD 1 Fuses 2 x 630 mA T Electrodes 60x85 mm 4 Electrodes 50x50 mm Sponges for Electrodes 60 85 Sponges for Electrodes 50x50 mm Elastic band 1000 mm Elastic band 600 mm Probe 1 3 Mhz 5 cm Electrotherapy Output cable Optional accessories gt pg 58 Technical specifications gt pg 68 POLYTER 6 10 POLYTER 6 POLYTER 10 In the basic configuration of the Polyter 6 the device is equipped with accessories for electro and magnetic therapy POLYTER 6 10 MULTIFUNCTIONAL DEVICES The Polyter in its two versions 6 and 10 was born as a portable electrotherapy ultrasound laser and mag netic therapy very suitable for sports centers and home based therapies POLYTER 6 In the basic configuration of the Polyter 6 the device is equipped with accessories for electro and magnetic therapy ELECTROTHERAPY 1electrotherapy channel 11 waveforms Frequency Hz 10 25 50 MAGNETIC THERAPY 1 output for magnetic therapy Maximum power 100 Gauss ULTRASOUND On request 1 output e 1IMHz continuous mode LASER On request 1 output 905 nm POLYTER 10 In the basic configuration of the Polyter 6 the device is equipped with accessories for electro and magnetic therapy ELECTROTHERAPY 2 electrotherapy channel 14 waveforms Frequency Hz 10 25 50 MAGNE
37. an be treated in a selective way both in depth and superficially K SOUND FOR A MULTI FREQUENCY TREATMENT Wide display 8 colour touch screen Device for ultrasound therapy with 3 frequencies 1 2 3 MHz Iwo completely independent outputs that deliver 2 different treatments simultaneously More than 100 therapeutic suggestions grouped according to anatomical areas specialist branches and frequencies Patient file for storing all patient s data treatments and short case history Help button Each therapeutic suggestion shows indications on its use and where to place the probe on the area under treatment Connection between K Sound and EleKtra for ultrasound electrotherapy combined treatments USB Key to store many personalised treatments and patient files Upgradable software SUPPLIED ACCESSORIES K SOUND Power cable 1 User manual in DVD 1 3 MHz probe 5 cm Fuses USB Key Optional accessories gt pg 58 Technical specifications gt pg 66 CHOICE OF ELEGANCE In the Prestige line technology and experience have been blended together to meet the needs of professionals who do not wish to waste their time Simplicity of use together with blue chip technology are the essential characteristics of these devices The interface of Prestige line devices is so simple and clear that you will not even need to read the user manual when switching the device on for the first time
38. asing metabolic activity in the area being treated and this helps to reduce the inflammation caused by the pain killing action of released local endorphin This system stimulates and accelerates the healing process The penetration depth varies from 4 to 7 cm Main application fields orthopaedics rehabilitation sport medicine aesthetic medicine SHOCK MED SHOCK MED SW1352 Device for radial shockwaves power up to 5 bar adjustable frequency 1 21 Hz _ INDICATIONS Shockwave therapy is the best treatment for chronic insertional tendinopathies characterised by poor vascularisation of the osteotendinous junc tion when the physiotherapeutic treatment infil trations and laser therapy has proved ineffective These are the main pathologies treated with shockwaves Elbow epicondylitis epitrocleitis Shoulder insertional tendinopathies impingement Knee patellar and goose s foot tendinopathies Pubis adductor tendinopathies pubalgy Ankle achilles tendinopathy calcaneal apophysis THE SMART SHOCKWAVE THERAPY Wide display 8 colour touch screen Procedure function A practical and handy application manual of the shockwave therapy based on four fundamental steps Localise the painful area by touch Select the therapy parameters manually or using preset programs Apply gel Start the shockwave therapy More than 40 therapeutic suggestions grouped acc
39. aterial that moves the charges ions in the subcutaneous tissues The electrodes come in dif ferent sizes for different body areas SUPPLIED ACCESSORIES HR TEK 1 1 User manual in DVD 1 1 Fuses 2 2 Applicator for resistive electrodes 1 1 Kit of resistive electrodes 30 50 70 80 mm Kit of resistive electrodes 0 30 50 70 mm Applicator for capacitive electrodes Kit of capacitive electrodes 30 50 70 80 mm Kit of capacitive electrodes 030 50 70 mm 1 USB Key 1 Bottle of conductive gel 1000ml 1 Steel plate 1 10ptional accessories gt pg 61 HR TEK DESK Technical specifications gt pg 74 pal CONTINUOUS MODE AND DUTY CYCLE Crystal Yag can work in continuous mode delivering power up to 25W or in Duty Cycle pulsed mode which alternates an emitting period with a non emitting period in order to decrease the power ef fect of the laser the photo thermal effect which induces an increase in local temperature and thus cool down the tissue area treated between pulses This system makes the biostimulation effect of tissue more effective and significant _ THERAPEUTIC INDICATIONS The protocols developed for high power Nd Yag laser therapy induce a rapid resolution of the most common pathologies in the following fields orthopaedics physiatry dermatology rheumatology and sport medicine cz CRYSTAL YAG DESK The list of the main pathologies that can be treat
40. d tissues a heat that is transmitted in depth ob taining an analgesic effect The higher heating occurs in tissues with more pres ence of water eg muscles and periarticular tissues whereas the lower heating effect occurs in those with a low content of liquid eg adipose tissue The radar therapy besides thermal effect causes va sodilatation that remains high for about 20 minutes after treatment and affects only capillaries and pre capillary arteries WHY RT250 DIGITAL New Design Medical Italia Easy to use very clear and easy interface 50 therapeutic suggestions Possibility to connect the device to a three dimensional antenna A3D model for applications in the shoulder neck spine and rectangular antenna AR model for applications on large areas like arms and legs spine neck 57 Multilingual software Pulsed and continuous emission mode Radar with swivel arm for easy attachment of multiple positions that allows multiple applications SUPPLIED ACCESSORIES RT250 DIGITAL 1 1 2 x 6 3 A T 1 1 1 User Manual DVD Fuses Pantograph arm High frequency output cable Circular antenna AC 191 Optional accessories gt pg 59 Technical specifications gt pg 72 9 B Bax Ultrasound Probes ACC666 1 ACC400 1 403 402 Sponges for electrodes 7 28 27 051 Self adhesive electrodes ACC231 ACC62
41. different chan nels or modify them use them in parallel alternate them apply them simultaneously synchronise them or apply them in a sequence you have an elec trotherapy with no limits The main effects of electro stimulation are training of the neuromuscular system to respond correctly during voluntary and involuntary strains with active contraction pain modulation by the gate control mechanism spasticity reduction by stimulating ag onists and antagonists transdermal release of me dicinal substances into the skin ionophoresis improvement of joint mobility by mechanical stretching of muscles improvement of injury heal ing by increasing local circulation resolution of oedema thanks to the activity of the muscle pump ELEKTRA ELECTROTHERAPY WITH NO LIMITS Wide display 8 colour touch screen More than 36 waveforms Low and Medium frequencies High Voltage Microcurrents NMES Stochastic APS and others More than 100 therapeutic suggestions grouped according to anatomical areas specialist branches and waveforms curve with value comparison before and after treatment Patient file for storing all patient s data treatments and short case history Help button Each therapeutic suggestion shows indications on its use and where to place electrodes Connection between EleKtra and K Sound for ultrasound electrotherapy combined treatments Connection between EleKtra and Vacuum
42. e therapy requires the presence of one operator The most important working parameters within laser therapy are power density power released per density of the irradiated tissue which is measured in W sq cm and is calculated dividing the output power for the irradiated spot dimension Fluency is the most important parameter for de termining the clinical effect of the laser since it measures the quantity of energy released per unit of irradiated tissue area It is measured in J sq cm and it is calculated multiplying the power density for the exposition length Each protocol supplied by Medical Italia indicates the fluency suggested for each kind of treatment The operator according to the area to treat and to the laser power will modify the treatment time or the frequency in order to convey the necessary fluency for the treatment LASERMED Available models LASERMED 2100 LASERMED 2200 TO CHOOSE LASERMED New Medical Italia design Color display with Touch amp scroll Automatic calculation of the fluence joules as a function of time and of the treatment s area amp Multilanguage software LASERMED 2100 111371 More than 80 therapeutic suggestions Probe with automatic contact sensor laser emission starts when the probe gets near the target Single channel desktop portable laser therapy device 905 nm equipped with one 25mW mono diodic laser probe MLA1 25 Wide range
43. ed includes arthrosis and degenerative processes of cartilage bursitis synovitis capsulitis epicondylitis shoulder impingement syndrome tendinitis and tenosynovitis oedema and trauma haematomas post traumatic or overload pathologies abductor syndromes sprains enthesitis patellar chondropathy and sport traumatology More specifically it is possible to treat ACUTE PATHOLOGIES Tendinopathy tendinitis peritendinitis tenosynovitis insertional and calcific tendinitis tendinosis partial lesions Distortion traumas and post traumatic oedemas Muscle lesions Synovitis and bursitis Back pain and lumbago Fibromyalgic syndrome Osteochondritis dissecans and osteochondral lesions DEGENERATIVE PATHOLOGIES Osteoarthrosis Degenerative chondropathies CRYSTAL YAG Available models CRYSTAL YAG CRYSTAL YAG DESK CRYSTAL YAG HL1364 CRYSTAL YAG Crystal Yag emits with a wavelength of 1064nm which falls in the laser therapeutic window that spans from 400 to 1600nm The light beam delivered by Crystal Yag can be regulated up to a maximum power of 25W which has a high value of tissue penetration Its effects provide photo chemical bio stimulations on the cellular membrane and inside the mitochondrions acting in depth in the tissues and inducing significant effects of metabolic analgesic anti oedema antiphlo gistic stimulation With Crystal Yag you can treat safely al
44. ed for combined treatments with vacuum therapy USB Key to store many personalised treatments and patient files Upgradable software SUPPLIED ACCESSORIES ELEKTRA 2 Power cable 1 User manual in DVD 1 Fuses 2pcs of 315mA T USB Key 1 Electrodes 60x85 mm Sponges for 60x85 mm electrodes Electrodes 50x50 mm Sponges for 50x50 mm electrodes Elastic band 1000 mm Elastic band 600 mm Electrotherapy output cable Optional accessories gt pg 59 Technical specifications gt pg 67 The main application fields are the following Orthopedics Dermathology Sport medicine Aesthetic medicine Periatricular pathologies Inflammatory pathologies of joints and tendons 500 0 K SOUND KS1305 OPERATING MODE AND BENEFITS The ultrasound therapy has an effect on human tissues and acts as a cellular and intracellular high frequency massage The tissues hit by ultrasound begin to vibrate with consequent expenditure of energy and production of heat so we have mechanical and diathermal effects Ultrasound therapy is applied to treat inflammations post traumatic circulatory affections skin diseases and diseases of peripheral nerves and to repair tissues With K Sound you will be able to use ultrasound univer sally thanks to 3 frequencies 1 2 and 3 MHz both in continuous and pulsed modes These frequencies have different absorption properties and therefore the tissue structures c
45. eforms Smart Card _ THERAPIC 9200 9400 DISTINCTIVE ELEMENTS New Medical Italia design 26 wave forms low and medium frequencies 4 completely independent channels with 2 mm banana cables Possible connection to ULTRASONIC family for combined usage Color display with Touch amp scrool function Curve comparing values at the beginning and a the end of the therapy Possible connection to the Vacuum model Vacuumed VU1392 for combined usage Electrodes test Creation of various treatment sequences having different waveforms Smart Card THERAPIC 7200 THERAPIC 9200 THERAPIC 9400 1 1 1 1 1 1 e of 315mA T e of 315mA T 2 of 315mA T 4 8 Optional accessories gt pg 59 Technical specifications gt pg 67 ULTRASONIC 1300 1 51321 single channel desktop portable ultrasound device equipped with 1 3 MHz probe ULTRASONIC 1500 US1322 two independent channels desktop portable ultra sound device equipped with two 1 3 MHz probes ULTRASONIC 1300 1500 New Medical Italia design Waterproof multifrequencies probes 1 3 MHz suitable for submerged treatments Possible connection to THERAPIC 7200 9200 9400 for combined usage Color display with Touch8scrool function Self calibrating probes with working frequencies internal storage system Ultrasonic 1500 two completely independent channels ultrasound device able to perform two autonomous treatment
46. g beauty care de vices Estetic Italia is the MEDITATED TECHNOLOGY for all those who work in the beauty care sector and need forefront fundamental and easy to use devices as well as the guarantee of great results and high quality M AnD MANUFACTURING DIVISION OEM Division for the production for third parties OEM designs and produces customized devices for physical therapy beauty care and aesthetics Our technology is at your disposal INNOVATION DIVISION Department for the creation of innovative products PRIMA ITALY o Jf Fondazione Santa Lucia Roma Istituto Santo Stefano Ancona Ospedale Umberto Napoli Ospedale di Palermo 1 Reggimento Carabinieri Paracadutisti Estav Nord Ovest Centro Sud Est Toscana Fondazione Don Carlo Gnocchi Azienda San Alto Adige Comprensorio San Bolzano SPAIN Area de Salud 5 6 Consilleria de Sanidad de la Comunidad Valenciana Centro de Atencion a mayores de la Generalidad Valencia Conselleria de bienestar Social De Valencia Centro Medico Zulaica Madrid Hospital de Henares de Madrid Fisiocentro Leon Servicio Aragones de Salus de Aragona i PORTUGAL Clinica do Palacio Lda Peso de Regua Clinica Med Fisica e Reabilitacao de Vizela Lda Guimaraes Cupido Clinico Servicos de Saude Lda Riba de Ave FRANCE Kin sith rapeute Brasier Pierre Annecy e Ecole Nationale de Kinesitherapie GERMANY T
47. gth scanning laser device with two simul taneous laser sources continuous laser emission 808 nm pulsed laser emission 905 nm The combination of the two laser sources allows a high anti inflammatory effect 808 nm together with an analgesic effect 805 nm allowing better results especially in acute phase diseases and with the presence of inflammation lumbago sprains neck pain etc PR999 8W 511367 High power scanning laser device A new laser that represents the state of the art in his family for its high performances 999 8W uses wavelength of 940 nm by means of a single 8 W diode Available models PR999 500 mw PR999 4W PR999 8W PR999 CHOICE OF PROFESSIONAL QUALITY Step motor the new system for moving the laser beam by means of step motor generates micro oscillations allowing to increase up to a maximum of 596 of the set treatment area The use of laser scanning is automatic since it does not require the presence of the operator The use of PR999 allows to treat larger areas with respect to a contact laser Automatic surface treatment setting PR999 500 mw SL1365 Adjustable scanning area up to 400 cm2 Possible connection of an external mono multi diodic laser probe Scanning laser device delivering a total power of 500 mW in continuous and pulsed mode operating wavelength 808 nm SCANNING LASER PR999 The application of the Scanning Laser t
48. hannel 1 3 Mhz ultrasound _ ULTRASOUND THERAPY Ultrasounds are used primarily to reduce the pain and the main treatments are sciatica neuritis periarthri tis The thermal effect produced by ultrasound in COMBIMED 2200 creases the temperature in deep tissues and ELECTROTHERAPY AND ULTRASOUNDS together with the mechanical effect the treatment FOR A WINNER COMBINATION results in a micro massage at the level of cellular structures Combimed 2200 is equipped with multi frequence probes 1 3 MHz that can be set by the operator in order to establish the depth of penetra tion required by the treatment with the frequency of 1MHz can be up to in depth while with MHz you can get up to 1 cm New winning design Color display with Touch amp scroll function Possible connection to VACUUMED VU1392 for combined usage 26 waveforms low and medium frequency Self calibrating probes with working frequencies internal storage system _ ELECTROTHERAPY ca Waterproof multifrequencies probes 1 3 MHz suitable for submerged treatments The Electrotherapy is used in order to stimulate den Curve comparing values at the beginning ervated muscle to reduce the hypotrophy due to non and a the end of the therapy use of the normal muscle maintain the muscular Multilanguage software trophism in denervated or partially innervated muscle More than 100 therapeutic suggestions to strengthen the inner
49. herapy allows to treat wider areas compared to the contact laser application and the operation is automatically carried out by the device itself without the presence of the operator SUPPLIED ACCESSORIES PR999 500mw PR999 4W PR999 8W Power cable 1 1 1 User Manual in DVD 1 1 1 Fuses e 630mA T 2 1 6 1 6 Laser protection goggles 2 2 Interlock safety key 1 1 Emergency stop switch 1 Smart Card 1 Optional accessories gt pg 63 ACC191 AC Circular antenna ACC234 AR Rectangular antenna ACC234 A3D Three dimensional Antenna The reduction in pain is caused presumably by two main components Indirect antalgic action secondary to the action on algogenic components muscular spasms and hypoxia eDirect antalgic action the most commonly ac cepted explanation for this action is based on the presumed counter irritating effect of heat accord ing to the gate control theory of Melzack and Wall However on the hypothesis of the counter irritating effect two partially contradictory factors must be considered the effect of the thermal increase on nervous conduction and the role of thermoreceptors On the first aspect the increase in temperature determines a proportional increase obviously within certain limits in the nerve trunk conduction velocity RADARMED 2500 RADARMED 2500 CP RT1341 Microwave therapy belongs to the family of ther motherapies By means
50. ino Roth Worbis Sportphysio Bitburg Bitburg SWITZERLAND Physio am Bahnhof Rueti UK e The Dove clinic for integrated medicine Hampshire Physiotherapy and Sport Injury Clinic Oxfordshire ROMANIA Hospital of Constanca Sanatorium Busteni CROATIA Daruvarske Toplice Specijalna Bolnica Za Medicinsku Rehabilitaciju SERBIA AND MONTENEGRO Clinical center belgrade Spa soko banja Basketball club fmp Hospital center loznica Hospital center cuprija GREECE General Hospital of Attika Athens Special Centre of handicap Athens General Hospital of Lesvlo Ishland LITHUANIA Sirvintu Hospital Druskininku Hospital Klaipeda Seamens Clinic INDIA Dg sports authority of india All india institute of medical sciences Doon hospital Guru jambashwer university gt Dolphin college College applied education Mt Medical hospital and college PAKISTAN Isra Islamic foundation Limited Hyderabad North Nazimabad Hospital Wapda Complex Hospital Feroze Pur Road Lahore Arm Forces Institute Rehabilitation sh Lr i pc 4 SM 1 n he 1 x eke ek 5 pos i RA T a hs EJ Assella Hospital Addis Abeba Police Academy Cairo El Tawheed Medical Center Port Said City Federal Assosiation of Football Cairo
51. isplay 1 1 1 1 1 99 minutes 0 30 minutes 0 50 mA da 0 a 100 Gauss linear 10 25 50 Hz stimul 3500 Hz Analgesic 200 Hz From 0 to 1 8 W continuous POLYTER 10 230 Vea 50 60 Hz 10 about 3 4 hours about 3 4 hours 10 VA IIB Alphanumeric bw 40x2 display 2 1 l Il 1 99 minutes 0 30 minutes 0 50 da 0 a 100 Gauss linear 10 25 e 50 Hz stimul 3500 Hz Analgesic 200 Hz from 0 to 2 W pulsed 10 100 in steps of 10 MODELS Power supply Maximum main power absorption Double mains fuse protection Backlit LCD Display to view and check the operating parameters Adjustable treatment time Number of pneumatic sectors outputs Maximum pressure Isolation class Risk class 93 42 CEE Alarm in case of damage of Kit Point Kit Point control test Automatic Kit Point deflation at the end of treatment Independent pressure adjustment for each sector Stored protocols Storable procotols on the Smart Card Storable procotols on the internal memory Weight Size PRESSOMED 2900 230 Vca 50 60 Hz 10 220 VA 16 Graphic colour 320x240 Pixel Touch amp scrool 1 99 minutes 9 150 mm Hg tipo BF 21 100 100 30 39 x 89 x 30 cm LASERTHERAPY MODELS Power supply Double delay type T mains Backlit LCD Display to view and check the operating parameters Length of the Diode laser emission wave Adjustable treatme
52. it is absorbed and converted into heat The temperature distribution caused by the ultrasound in the tissues is unique within all forms of deep heating the temperature increases relatively little inthe tissue surface and it is more likely to penetrate into the muscles and the soft tissues compared to the diathermic effect produced with short waves or mi crowaves Chemical effect it is strictly connected to a typical phe nomenon caused by ultrasounds the so called cavitation which takes place in the fluid components of the tissues where the small gas bubbles tend to increase their dimen sion and starts the oxidation polymerization and the de struction of macromolecules ULTRASONIC 2500 DISTINCTIVE ELEMENTS New Medical Italia trolley design Waterproof multifrequencies probes 1 3 MHz suitable for submerged treatments Possible connection to THERAPIC 7200 9200 9400 for combined usage Color display with Touch amp scroll function Self calibrating probes with working frequencies internal storage system Ultrasonic 2500 has two completely independent channels ultrasound device able to perform two autonomous treatment at the same time Equipped with one orthostatic arm Smart Card ULTRASONIC ULTRASONIC 1500 2500 1 1 1 1 2 of 630mA T 2 of 630mA T 2 1 1 1 COMBIMED 2200 COMBIMED 2200 CO1325 Combined device for electrotherapy with 2 channels electrotherapy and 1 c
53. l muscle skeletal inflammatory conditions both superficial and in depth inducing already in the first session a decrease in pain and mobility recovery EFFECTS ON TISSUE Significant mitochondrial stimulation with the following increase Production of ATP photochemical effect it accelerates the transformation process of AD into ATP the elec trolyte replacement between intra and extra cellular environments Activation of micro circulation photo thermal effect it activates the replacement modifying the intracapillary hydrostatic pressure Activation of lymphatic peristalsis photo mechanical effect the deep lymphatic system is stimulated causing a rapid absorption of the inflammatory agents with effective results also in the fluid accumulations Hyper polarization of the nerve fibre membranes causing an analgesic effect the perceptual threshold of the algotrope endings rises up and the release of endorphin increases significantly WINNING FEATURES Wide display 8 colour touch screen and updatable software Wide choice of therapeutic suggestions grouped according to anatomical areas specialist branches Patient file for storing all patient s data treatments and short case history USB Key to store many personalised treatments and patient files Help button Each therapeutic suggestion shows indications on its use _ GUARANTEED RESULTS Reduction of pain in some cases with
54. mA Limited to 50 mA 100 mA 100 V 2 250 200 100 10 4 Gb 44 Kg 39 x 14 x 30 THERAPIC 2000 230 50 60 Hz 10 30 2 x 630 mA T Graphic bw 240 x 128 Pixel 1 99 minutes Constant Voltage Constant Current Until 4 000 HZ Limited to 30 mA Limited to 50 mA 100 mA 100 V 2 50 50 4 3 39 x 14 x 30 cm MODELS Power supply Maximum main power absorption Risk class 93 42 CEE Double delay mains fuse Backlit LCD display to view and check the operating parameters Stored protocols Storable programs on the internal memory Storable programs on the Smart Card Numeric generation of waveforms using DSP Vacuumed connection Possibility to update the software ELECTROTHERAPY SECTION Adjustable treatment time Output channels for electrotherapy Low and medium frequency currents Operation Peak power Peak power on other wave forms Creation of the curve of the Rheobase and Chronaxie Allarm incorrect output load Weight Size ULTRASOUND SECTION Adjustable treatment time Output channels for ultrasounds Emission frequency Adjustable duty cycle Peak power on continuous mode Peak power on pulsed mode Automatic recognition of the probe Low BNR self calibrating probes Water resistant probes TECHNICAL SPECIFICATIONS COMBIMED 200 230 Vca 50 60 Hz 10 60 VA IIB 630 mA T Graphic bw 240 x 128 Pixel 25 for Electrotherap
55. ndings and the release of endorphins Effects on the peripheral nervous system analgesic and regenerative Effect of bio stimulant and tissue regeneration Effect on the micro circulation and on the blood veins The laser entails an enhancement of the local microcirculation that includes the relief of local spasms of arteries and veins that take place for example after a trauma or an inflammation determines an intensification of the blood flow within the nutritional capillaries Effect of photoenzymatic activation Placebo Effect WHY LIS 1050 New Design Medical Italia Easy to use very clear and easy interface Influx Automatic calculation Joules Multilingual software 50 therapeutic Suggestions Probe with automatic contact sensor if the lens is close to the skin it begins delivering laser Possibility to connect different laser probes monodiodic or multidiodic up to a maximum power of 800 mW SUPPLIED ACCESSORIES LIS 1050 Power cable 1 User Manual in DVD 1 Fuses 2 3 15 A T Laser Probe MLA1 25 mW 1 Laser goggles 2 Interlock security key 1 Optional accessories gt pg 63 Technical specifications gt 70 MAGNETOMED 2000 WHY MAGNETOMED 2000 New Design Medical Italia Exclusive MFC patented Solenoid magnetic induction produced outside the solenoid is drastically reduced concentrating the lines of force within the same uis thus affecting o
56. nly the patient and no more the operator Easy to use very clear and easy interface 50 therapeutic suggestions MAGNETOMED 2000 Maximum output power 100 Gauss for each channel Multilingual software Magnetomed 2000 only generator is a device for mag netic therapy with 2 outputs that generates a magnetic field at low frequency adjustable from 1 to 100 Hz with an intensity up to 100 Gauss for each output causing beneficial effects especially on tissue regeneration and bone tissue MANN INDICATIONS Recent fractures and nonunion Osteoporosis Nonunion Sudeck s disease and osteoporosis Arthropathies of inflammatory and degenerative nature Arterial occlusive disease Bedsores Psoriasis SUPPLIED ACCESSORIES MAGNETOMED 7200 8200 8400 Power cable 1 User Manual in DVD 1 Fuse 2 x315mA T Ring magnet to test the unit 1 Optional accessories gt pg 60 Technical specifications gt pg 71 _ THERAPEUTIC ACTIONS Reduction of Improvement of the Collagen extensibility Reduction of stiffness Reduction of edema and inflammatory exudates Increase the blood flow _ 250 DIGITAL RT250 DIGITAL RT1341 RT 250 Digital Electric radar therapy Equipment for radar therapy with continuous and pulsed operation mode RADARTHERAPY Radartherapy make use of electromagnetic waves in the frequency band of microwaves which develop in the treate
57. nnection the device to electrotherapy model THERAPIC 2000 TH1310 for combined applications Graphic display with a very good resolution Easy to use very clear and easy interface Waterproof probes for underwater treatments Multilingual software 50 therapeutic suggestions SUPPLIED ACCESSORIES Power cable User Manual in DVD Fuses 2 da 630 mA T Probe 1 3 Mhz 5 cm 1 Optional accessories gt pg 58 Technical specifications gt pg 66 200 200 New Design Medical Italia Two totally independent outputs for electrotherapy Possible connection to the vacuum therapy model Vacuumed VU1392 for combined applications Electrodes test Waveforms low and medium frequency Minimum size for two essential technologies GOMBIMED EDU in physiotherapy Easy to transport Graphic display with a very good resolution Combined or independent device for electrotherapy p and ultrasound at 1 3 Mhz Easy to use interface very easy and clear Ultrasonic waterproof probe for Combimed 200 allows to carry out treatments of underwater treatments ultrasound and electrotherapy simultaneously in independent mode or to use the two treatments in combined mode thus coupling the analgesic action of electrotherapy to the thermal and mechanical effect of ultrasound making the result of the treatment even more effective especi
58. nt time Adjustable pulse frequency Pulse duration Pulsed mode Output channels Isolation class Risk class 93 42 CEE Laser classification Stored protocols Storable procotols on the internal memory Storable programs on the Smart Card Automatic contact sensor Possibility to update the software Weight Size VACUUM THERAPY MODELS Main power supply LASERMED 2100 230 Vca 50 60 Hz 10 315 mA T Graphic colour 320 x 240 Pixel Touch amp scrool 905 nm 1 99 minutes 200 10 000 Hz 100 nsec 10 100 1 IIB 3B 82 200 200 4 39 14 30 Maximum power absorbed from the mains Risk class MDD 93 42 CEE Treatment time Range di temperature operative Depressione realizzabile Maximum pulses with full scale frequency Electric output channels Table container in plastic external size width x height x depth Weight LASERMED 2200 230 50 60 Hz 10 315 mA T Graphic colour 320 x 240 Pixel Touch amp scrool 905 nm 1 99 minutes 200 10 000 Hz 100 nsec 10 100 2 indipendenti BF Type IIB 3B 82 200 200 4kg 39 x 14 x 30 cm VACUUMED 230 Vca 50 60Hz 10 25 Adjustable 10 40 0 0 6 bar 60 with minimum suction intensity 15 with minimum suction intensity 2 independent outputs 340 x 110 x 355 mm 6 4 Kg LIS 1050 230 Vca 50 60 Hz 1096 315 mA T Graphic bw 2
59. of electro magnetic waves heat is conveyed deep within tissues Therapeutic effects of radartherapy are muscular heating analgesic and throphic effect Microwave therapy is indicated in case of muscular contrac tures osteoarthritis posttraumatic pain tendinitis etc _ THERAPEUTIC ACTIONS Pain reduction Improvement of collagen extendibility Reduction in joint rigidity Oedema and inflammatory exudates reduction Increase in the haematic flux RADARMED 2500 CP THE MICROWAVE DIATHERMY New Medical Italia design Easy to use friendly user interface New orthostatic arm realized with aluminum alloy and preloaded joints without manual adjustment 100 therapeutic suggestions Possible connection of the three dimensional antenna A3D model for applications on the shoulder neck spine The rectangular antenna AR model can be connected too for applications on large areas such as upper and lower limbs cervical area spine New system for fast antenna connection Multilanguage software Pulsed and continuous emission mode Smart Card SUPPLIED ACCESSORIES RADARMED 2500 CP Power cable 1 User Manual in DVD 1 Fuses 2 da 6 3 Orthostatic pantograph arm 1 High frequency output cable 1 Circular antenna AC ACC191 1 Smart Card 1 Optional accessories gt pg 59 Technical specifications gt pg 72 551 1 60 High tech bed with 1 mouwa ACC615
60. ording to anatomical areas specialist branches Patient file for storing all patient s data treatments and short case history Help button Each therapeutic suggestion shows indications on its use One Touch mode by pressing just once the activation button the procedure will start and continue until the end of the therapy or until the operator will press again the button to pause the execution of the treatment Soft Rebound System rebounding to the therapist s arms was reduced by 9596 thanks to the new applicator developed by EME which has an internal spring system to dampen the rebound effect USB Key to store many personalised treatments and patient files SUPPLIED ACCESSORIES SHOCK MED Power cable 1 User manual in DVD Fuses USB Key Shock Med applicator 9mm multifocused transmitter 15mm focused transmitter 15mm multifocused transmitter Gel 260ml Interchangeable kit Optional accessories gt pg 62 Technical specifications gt 74 DIATHERMY WITH SENSATIONAL EFFECTS is an innovative therapeutic device for en dothermal energetic transmission with capacitive re sistive modes It stimulates from the inside the biological structures tendons muscles joints and natural reparative and anti inflammatory processes of the human body By the interaction between electro magnetic energy and tissue diathermy causes the temperature inside
61. ovide our cutting edge technology to the international markets to become a trusted partner for whom relies on us to achieve successful targets to devise ad hoc solutions that meet the needs of our partners to search for new solutions in the design and characteristics of each product and to invest on quality and excellence Made in Italy OUR VALUES OUR VALUES INNOVATION applied in the research and development of technologically advanced products and in the offer of qualified services oriented to the total satisfaction of the Client who is the real employer of our company VALUE OF HUMAN RESOURCES involving and motivating each employee of the company VALUE OF HEALTH each environment inside the com pany is equipped with a device for air depollution to pro tect the health of each employee INDUSTRIAL VOCATION applied in the development and production of high performance quality products RESPECT OF THE ENVIRONMENT at EME we are replac ing more and more paper with digital documents and we use materials and paints with a low environ mental impact _ RESEARCH AND DEVELOPMENT The department of Research and Development is the heart of EME group In the R amp D department our spe cialists process the inputs from the users in order to develop new products improve existing ones and make them all unique products that stand out from those of our competitors _ QUALITY SYSTEM EME Srlis certified ISO 9001 20
62. pacitive electrode 30 mm e 1307 5 Capacitive electrode 9 50 mm e e ACC1307 7 Capacitive electrode 70 mm e e ACC1307 8 Capacitive electrode 80 mm e 1506 1 Steel plate 1310 Cylindrical mass e 1506 2 Canister of conductive cream 1000 ml e e e ACC606 Pack of 10 patient smart cards e CONT72 Transport bag in tnt fabric e ACC604 3 shelf trolley e ACC1317 2 E USB key mm Pei 109 el ACC1274 ACC606 ACC1317 2 E ACC604 ACC954 OPTIONAL ACCESSORIES BIPOWER LUX VIKARE CRYSTAL YAG CRYSTAL YAG 6W 12W 4W 8W DESK ACC1274 Defocused laser probe with optical fibre 4 spot sizes ACC606 Pack of 10 patient smart cards 954 Laser protective goggles e CONT72 Transport bag in tnt fabric e ACC604 3 shelf trolley e e ACC1317 2 E USB key e e e ACC536 GC9 ACC334 GC9 S ACC533 BC7 PRO La twm iil ACC535 BCbx2 ACC606 OPTIONAL ACCESSORIES PRESSOMED 2900 ACC536 GC9 Kit point with 9 sectors for lower limbs e The kit is composed of 2 leg sleeves with 6 sectors 1 inguinal sector 2 abdominal Sectors internal air chambers in latex Velcro closure ACC334 GC9 S Kit point with 9 sectors for lower limbs and separate foot sector The kit is composed of 2 foot sectors 2 leg sleeves with 4 sectors 1 inguinal sector 2 abdominal sectors internal air chambers in latex Velcro closure ACC533 BC7PRO Kit point with 7 sectors for
63. quency Display Risk class 93 42 CEE Intensity of electrical discharge Frequency of electrical discharge Treatment period SWT SHOCK MED 230 50 60 Hz 10 80 550 VA from 50Hz to 60Hz Graphic colour LCD 8 Touch Screen 1 5 Bar max 1 22 Hz max 0 2 millions rounds Stored protocols 20 Storable protocols on the internal memory 200 Storable protocols on the Smart Card Storable protocols on the USB 4 Gb Patient s Card Help on line One touch mode Weight 31 Kg Size ENDODIATHERMY MODELS Power supply Double delay type T mains Backlit LCD display to view and check the operating parameters Adjustable treatment time Operation frequency Peak power Isolation class Risk class 93 42 CEE Output channels Probe supplied with power adjustment buttons Stored protocols Storable programs on the internal memory Storable programs on the Smart Card Storable programs on the USB Size Weight 230 Vca 50 60 Hz 10 230 Vca 3 15 5x20 mm Graphic colour 320 x 340 pixel Touch Screen until 30 minutes 455 Khz 10 Max 300 Watt BF Il B 2 nioutput capacitive use n 1 output resistive use 2 n 1 for capacitive use n 1 for resistive use 48 200 4 Gb Trolley 39 x 89 x 30 cm 30 Kg SHOCK MED COMPACT 230 Vca 50 60 Hz 1096 80 VA 550 VA from 50Hz to 60Hz IIB 1 4 Bar max
64. rea stimulating the circulation and the oxygenation and accelerating the turnover of substances and the elimination of toxins In the peripheral tissues the oxy gen levels increase substantially and the carbon diox ide decreases by improving the blood flow the exchange activity in the capillaries is favored and by accelerating the blood flow the venous stasis which is the main cause of various veins and venous insufficiency The vacuum application combined with the stimulation currents will be carried out using vacuum electrodes Such electrodes are connected through pipes to a suction pump which causes a negative pressure inside the electrodes During this action the high depression requires a great quantity of blood hyperemia thereby improving the therapy effect through the different stimulation currents INDICATIONS Such therapy is clearly useful for treating all forms of vascular diseases affecting the legs arteriosclerosis of lower limbs Burger Raynaud and all forms of ve nous and or lymphatic insufficiency such as swollen legs lymphedema phlebolymphedema and cellulitis DISTINCTIVE ELEMENTS Suction using the encoder you can increase or decrease the level of suction Frequency it is possible to increase or decrease the period of time between a suction and the following Combined use simply connect Channel 1 of THERAPIC or COMBIMED to VACUUMED via its dedicated LINK cable to perform combined treatmen
65. reach the specific objectives Electrotherapy is used to stimulate the denervated muscle to reduce the hypotrophy caused by not using the normally innervated muscle to maintain the mus cular trophism in the denervated or partially innervated muscle and to strengthen the innervated muscle The main effects of applying the current to a body tissue are the excitomotor thermic trophic anal gesic and chemical effects Each electric pulse of muscular stimulation is characterized by WAVE FREQUENCY measured in Hz hertz WAVELENGTH measured in msec milliseconds INTENSITY measured in mA milliamper SUPPLIED ACCESSORIES Power cable User Manual in DVD Fuses Electrodes 60x85 mm Sponges for Electrodes 60x85 mm Electrodes 50x50 mm Sponges for Electrodes 50x50 mm Elastic band 1000 mm Elastic band 600 mm Electrotherapy Output cable Smart Card Available models THERAPIC 7200 THERAPIC 9200 THERAPIC 9400 _ THERAPIC 7200 DISTINCTIVE ELEMENTS New Medical Italia design 21 wave forms low frequencies 2 completely independent channels with 2 mm banana cables Possible connection to ULTRASONIC family for combined usage Color display with Touch amp scrool function T Curve comparing values at the beginning and a the end of the therapy Possible connection to the Vacuum model Vacuumed VU1392 for combined usage Electrodes test Creation of various treatment sequences having different wav
66. resistance that are interposed between us 2 the movable electrode and the return plate namely Resistive probe 1 bones joints tendons ligaments cartilages Resistive electrodes kit 30 mm 50 mm 1 HR TeK Basic used in resistive mode gives excellent Capacitive probe 1 results in Capacitive electrodes kit 30 mm 50 mm 1 general traumatology Conductive cream 1000 ml 1 sports traumatology Stainless steel plate 1 arthritis Smart Card 1 arthrosis sterdinitis Optional accessories gt pg 61 Technical specifications gt pg 74 capsulitis and bursitis calcaneal apophysis VIKARE THE LASER POWER The new ViKare range of lasers is realized using op tical fiber to convey high power laser beam 4W 8W directly on the skin without losses Vikare therefore allows an immediate improvement in the symptoms of inflammatory and degenerative pathologies 5 use in orthopaedic neurological and dermatological context reduces healing time and makes ViKare essential especially in sports medicine as it allows fast recovery for athletes for whom time is a determining factor in their career Fields of application The fields of application that can benefit from ViKare laser therapy Sports Traumatology General medicine and dermatology e Arthro rheumatic pathology Rehabilitation therapy VIKARE Available models VIKARE 4W VIKARE 8W VIKARE 4W HL1360 VIKARE 8W HL1361 VIKARE IS TH
67. rovide up to 8W of power performing a strong regeneration action in chronic diseases speeding up the process of resolution of inflammation and oedema in the acute illness as well as the rapid resolution of pain syn dromes in joints muscles and soft tissues VIKARE LUNGHEZZA D ONDA WAVELENGHT nm 200 300 400 500 600 700 800 940 1000 1100 1200 1300 1400 10600 Epidermide Epidermis Osso Bone ACCESSORIES SUPPLIED VIKARE 4 8W Laser protection goggles Multispot laser probe User Manual in DVD Power cable Fuses Smart Card Optional accessories gt pg 61 Technical specifications gt pg 73 THERAPIC 9200 1312 Two independent channels electrotherapy able to supply all the low frequencies and medium frequen cies waveforms and the creation of curve rheobase chronaxie THERAPIC 9400 TH1313 Four independent channels electrotherapy able to supply all the low frequencies and medium frequen cies waveforms and the creation of curve rheobase chronaxie _ MAIN EFFECTS OF THE ELECTROSTIMULATION Training of the neuromuscular system to react appropriately during the voluntary and involuntary effort by providing an active contraction isometric concentric and eccentric and the following articula tion movements which allow a proprioceptive feedback Pain modulation through the gate control system or the descending inhibition mechanisms production of endogenous opioids
68. rrent Continuous currents lonthophoresis Diadynamic currents Peak currents with other wave forms Peak power Independent output channels Alarm incorrect output load Automatic and or manual polarity inversion Stored protocols Storable programs on the internal memory Storable curve diagnose Protocols in sequence 80 Storable programs onthe Smart Card Storable programs on the USB Ultrasound connection Vacuumed connection Possibility to update the software Weight Size TECHNICAL SPECIFICATIONS THERAPIC 7200 9200 230 Vea 50 60 Hz 10 30 VA 2 x 630 mA T Graphic colour 320 x 240 Pixel Touch amp Scrool 1 99 minutes Constant Voltage Constant Current IIB Until 4 000 HZ Limited to 50 mA Limited to 70 mA 120 mA 100 V 2 100 200 100 10 50 programs 20 curve diagnose 10 protocols in sequence 44kg 39 x 14 x 30 cm THERAPIC 9400 230 Vca 50 60 Hz 1090 35 VA 2 x 630 mA T Graphic bw 320 x 240 Pixel Touch 8 Scrool 1 99 minutes Constant Voltage Constant Current IIB Until 4 000 HZ Limited to 50 mA Limited to 70 mA 120 mA 100 V 4 100 200 100 10 50 programs 20 curve diagnose 10 protocols in sequence 44 Kg 39 x 14 x 30 ELEKTRA 2 230 Vca 50 60 Hz 1090 30 VA 315 mA T Graphic colour 8 Touch Screen 1 99 minutes Constant Voltage Constant Currente IIB Until 4 000 HZ 500V Limited to 50
69. rt traumatology arthritis arthrosis tendinitis capsulitis and bursitis calcaneal spur syndrome HR TEK LET THE WARMTH HEAL YOU Wide display 8 colour touch screen Output power up to 300W Exclusive applicator for resistive and capacitive treatments with integrated power regulating button available only for the model HR Patient file for storing all patient s data treatments and short case history Help button Each therapeutic suggestion shows indications on its use More than 40 therapeutic suggestions grouped according to anatomical areas specialist branches USB Key to store many personalised treatments and patient files Meter of the real treatment time by the new contact detection system Impedance meter displaying real time values HOW IT WORKS HR TeK is composed of a generator that conveys alternate current and an application circuit consisting in two elec trodes The electrodes are applied to the patient s body which becomes a part of the electric circuit There are different types of electrodes resistive type electrodes the treatment is delivered through a resistive non isolated electrode that moves the charges and concentrates them in the deeper areas with a greater resistance bone matrix and deep muscles capacitive type electrodes the capacitive contact transfer is executed through an electrode shielded with a ceramized isolating m
70. s 45 x 35 mm 4 pcs ACC432 Self adhesive electrodes 45 x 80 mm 4 pcs ACC431 Self adhesive electrodes 46 x 47 4 pcs ACC433 Self adhesive electrodes 45 x 98 4 pcs ACC436 Self adhesive round electrodes 32 mm 4 pcs ACC435 Self adhesive round electrodes 50 mm 4 pcs ACC434 Self adhesive round electrodes 9 75 mm 4 pcs ACC231 it of galvanic basins ACC624 Link cable for combined use of electrotherapy ultrasound ACC603 8 2 channel electrotherapy output cable ACC603 9 4 channel electrotherapy output cable ACC606 Pack of 10 patient smart cards ACC601 Uro gynaecology kit CONT72 Transport bag in tnt fabric ACC604 3 shelf trolley ACC1317 2 E USB key 4 22433 ACC616 Radar antennas OPTIONAL ACCESSORIES 22433 Orthostatic arm ACC616 High frequency radar cable 191 round antenna ACC235 A3D 3 dimensional antenna ACC234 AR rectangular antenna ACC606 Pack of 10 patient smart cards TE ACC400 1 ACC403 402 Spongesfor electrodes ACC28 ACC27 ACC051 gt ACC601 ACC606 ACC603 8 ELEKTRA e RADARMED ACC231 ACC603 9 THERAPIC 7200 9200 9400 THERAPIC 9400 RT 250 DIGITAL THERAPIC 2000 ACC544 LC60 2 ACC549 CP30 ACC550 CP50 ACC615 CP _ ACC543 LC60 ACC604 ACC606 OPTIONAL ACCESSORIES ACC549 CP30 550 CP50 ACC615 CP ACC551 1 LC60 2 551 LC6
71. the tissues to increase in a controlled uniform way DESK TeK stimulates the increase of haematic flux in a direct way thanks to the increase of temperature and indirectly thanks to the request for oxygen by tissues treated the increase of blood induces an increase in immune defences and stimulates tissue regeneration The main application fields are the following Dermatologic pathologies Traumatology Sport medicine Aesthetic medicine Skeletal muscle pain Inflammatory pathologies of joints and tendons Periarticular pathologies bursitis calcifications etc Available models HR DESK HR TEK HR HT1344 OPERATING MODE AND BENEFITS CAPACITIVE the effect is concentrated in the area under the mobile electrode It acts on soft tissues rich in water such as muscles the lymphatic system etc HR TeK when used in capacitive mode gives ex cellent results in the treatment of fracture after effects articular and peri articular pathologies drainage of post traumatic oedemas RESISTIVE it is effective with all tissues with a higher resistance and a low water content The biological effect is obtained in the tissues with a higher resistance interposed between the mobile electrode and the return plate that is bones joins tendons ligaments and cartilages HR TeK when used in resistive mode gives excellent results in generic traumatology spo
72. ts Vacuum output the four Vacuumed outputs can work together and simultaneously otherwise you can use just two of them by means of the specific cable to cover the other two outputs see the picture Low noise level Vacuumed is equipped with a low noise emission compressor in order to perform a relaxing therapy Smart case the rectangular shape of VACUUMED allows to allocate another Medical Italia equipment ELECTROTHERAPY COMBIMED above the same further reducing the overall dimensions SUPPLIED ACCESSORIES VACUUMED Power cable 1 User Manual in DVD 1 Fuses 2 of 315mA T Vacuum cups 0 60 mm 4 Cup sponges 0 60 mm 8 Output cables 4 Electrotherapy LINK connection cable 1 Optional accessories gt pg 64 Technical specifications gt pg 70 INDICATIONS ON THE USE OF LASER e Rheumatology Orthopedics Dermatology Dentistry Otolaryngology Neurology e Acupuncture LASERMED 2200 LT1372 Two channels desktop portable laser therapy device 905 nm equipped with one 25mW mono diodic laser probe MLA1 25 LASERMED LOW POWER LASER THERAPY Lasertherapy can be divided into contact and scan ning therapy and both modes can employ monodi odic and multi diodic lasers As far as laser therapy carried out with monodiodic contact lasers probes with direct contact on the skin are employed The treatment is based on the stimulation of the trigger points or of the areas affected by pain and th
73. upper limbs designed for post mastectomy applications e ACC535 BC5 x2 Kit point with 7 sectors for upper limbs general purpose applications ACC606 Pack of 10 patient smart cards e 3 alal ACC944 ACC946 ACC947 ACC948 ACC945 ACC606 ET s ACC1317 2 E ACC604 CONT72 OPTIONAL ACCESSORIES SHOCK MED SHOCK MED COMPACT ACC944 Applicator with 15 mm transmitter e 946 Focused transmitter 15 mm e e ACC947 Multi focused transmitter 9mm e 94 Multi focused transmitter 15 mm e e 945 Interchangeable kit for the applicator ACC606 Pack of 10 patient smart cards CONT72 Transport bag in tnt fabric ACC604 3 shelf trolley ACC1317 2 E USB key e ee v ACC605 1 ACC062 OPTIONAL ACCESSORIES MULTIDIODIC PROBES ACC681 MLA3 75 ACC682 MLA3 150 ACC683 MLA3 300 ACC684 MLA5 125 ACC685 MLA5 250 ACC686 MLA5 500 ACC687 MLA8 200 ACC688 MLA8 400 ACC689 MLA8 800 MONODIODIC PROBES ACC553 MLA1 25 ACC678 MLA1 50 679 MLA1 100 ACC680 MLA1 500 POWER ACC691 MLA ACU ACC601 ART22120 ART22125 ACC600 ART22157 ART2230 MLAI ACC605 1 062 954 ACC539 2 ACC606 CONT72 ACC604 Multidiodic probe UE y a ACC954 ACC539 2 ACC606 CONT72 Monodiodic probe Are used to widen the area to be irradiated Laser probe with 3 diodes of 25mw 75mw in total guide light Laser probe with 3 diodes of 50 mw 150 mw in total guide light Laser probe
74. vated muscle The main ef electrotherapy ultrasound combined protocols fects of an electric current applied to a body tissue Smart Card are represented by the thermal trophic analgesic and chemical effects COMBIMED has 26 low and medium SUPPLIED ACCESSORIES COMBIMED 2200 frequency waveforms which can be used on a channel Poner ebie 1 or on two channels in a synchronous or independent way User Manual in DVD 1 F 2 x 630 mA T _ COMBINED TREATMENT Electrodes 60x85 mm The pre set protocols of COMBIMED 2200 allow to Electrodes 50x50 mm realize a fast and easy combined treatment which Sponges for Electrodes 50x50 60x85 sums the analgesic and hyperemic effect of electrical Elastic band 600 mm 1000 mm stimulus with the mechanical and thermal ultrasound Probe 1 3 MHz 5 effect Electrotherapy Output cable Smart Card Optional accessories gt pg 58 Technical specifications gt pg 68 VACUUMED VACUUMED VU1392 VACUUMTERAPIA The Vacuum therapy is a therapeutical method which uses the effect of the vacuum in the body by combin ing the improvement of the tissue microcirculation with an anti inflammatory and detoxing action Concretely the vacuum therapy consists in applying an inner tube to a body part in which a depression is cre ated and afterwards a compression to stimulate the venous and lymphatic circulation this causes a suction effect which increases the blood afflux in the involved a
75. ver 50 x 50 mm e ACC28 Stretch bandage 1000 x 50 mm e e ACC27 Stretch bandage 600 x 50 mm e e 051 Probe for manual stimulation e e ACC430 Self adhesive electrodes 45 x 35 mm 4 pcs e e ACC432 Self adhesive electrodes 45 x 80 mm 4 pcs e e ACC431 Self adhesive electrodes 46 x 47 4 pcs e e ACC433 Self adhesive electrodes 45 x 98 4 pcs e e ACC436 Self adhesive round electrodes 32 mm 4 pcs e e ACC435 Self adhesive round electrodes 50 mm 4 pcs e ACC434 Self adhesive round electrodes 75 mm 4 pcs e e ACC231 Kit of galvanic basins e e ACC624 Link cable for combined use of electrotherapy ultrasound e ACC605 BO U Orthostatic arm e e e ACC606 Pack of 10 patient smart cards e ACC601 Uro gynaecology kit ACC603 8 2 channel electrotherapy output cable e e CONT72 Transport bag in tnt fabric ACC604 3 shelf trolley 1317 2 USB key di in Self adhesive electrodes ACC624 ACC606 22 CONT72 ACC604 ACC1317 2 E OPTIONAL ACCESSORIES ACC400 1 Conductive rubber electrode 80 x 120 mm ACC403 Conductive rubber electrode 60 x 85 mm ACC402 Conductive rubber electrode 50 x 50 mm ACC401 Sponge electrode cover 80 x 120 mm ACC003 Sponge electrode cover 60 x 85 mm 001 Sponge electrode cover 50 x 50 mm ACC28 Stretch bandage 1000 x 50 mm ACC27 Stretch bandage 600 x 50 mm 051 Probe for manual stimulation ACC430 Self adhesive electrode
76. with 3 diodes of 100 mw 300 mw in total guide light Laser probe with 5 diodes of 25 mw 125 mw in total guide light Laser probe with 5 diodes of 50 mw 250 mw in total guide light Laser probe with 5 diodes of 100 mw 500 mw in total guide light Laser probe with 8 diodes of 25 mw 200 mw in total guide light Laser probe with 8 diodes of 50 mw 400 mw in total guide light Laser probe with 8 diodes of 100 mw 800 mw in total guide light Laser probe 905 nm with 1 diode of 25 mw guide light Laser probe 905 nm with 1 diode of 50 mw guide light Laser probe 905 nm with 1 diode of 100 mw guide light 808 nm with 1 diode of 500 mw guide light alata Laser probe Kit for laser acupuncture composed of laser probe with 1 diode of 25mw with special focusing lens Round lens for Round lens for MLA3 Round lens for 5 8 Conical lens for MLA ACU Probe holder for MLA5 MLA8 Probe holder for MLA1 MLA3 Pantographic arm for 1 MLA3 MLA5 MLA8 EME laser protective goggles Laser protective goggles nterlock Pack of 10 patient smart cards Transport bag in tnt fabric 3 shelf trolley Probe holder pum Yne ACC604 LASERMED 2100 2200 LIS 1050 PR999 B 2 5 ACC400 1 403 ACC402 Spongesforelectrodes ACC28 27 Self adhesive electrodes 2 i d ACC300 ACC559 ACC528 1 0
77. y 25 for Ultrasounds 50 1 99 minutes 2 independent outputs 16 wave forms Constant Voltage Constant current 100 V 100 mA 7 39 x 14 x 30 1 30 minutes 1 1 MHz e 3 MHz 1596 10 10096 2 W 20 3 W 20 COMBIMED 2200 230 50 60 Hz 1096 60 VA IIB 630 mA T Graphic bw 320 x 240 Pixel Touch amp scrool 40 for Electrotherapy 40 for Ultrasounds 20 combined programs 100 for Electrotherapy 100 for Ultrasounds 200 1 99 minutes 2 independent outputs 17 wave forms Constant Voltage Constant current 100 V 120 MA 7 Kg 39 x 14 x 30 1 30 minutes 1 1 MHz e 3 MHz 15 1095 10096 2 W 20 3 W cm 20 MULTIFUNCTIONAL EQUIPMENT MODELS Power supply Battery duration Recharge time Maximum main power Risk class 93 42 CEE Backlit LCD display to view and check the operating parameters Outputs channels for electrotherapy Output channels for laser therapy Output channels for magneto therapy Output channels for ultrasounds Adjustable treatment time Adjustable ultrasound treatment time Operative acoustic signals Deliverable current for electrotherapy applications Magnetotherapy Intensity of the applied field Magnetotherapy frequency IR diode laser control Ultrasound control PRESSURE THERAPY POLYTER 6 230 50 60 Hz 10 about 3 4 hours about 3 4 hours 10 VA IIB Alphanumeric bw 40x2 d

Download Pdf Manuals

image

Related Search

Related Contents

hussman RHR-HEX User's Manual  NAD Electronics FWC555 User's Manual  www . ElectricalPartManuals . com  4. utiliser razer surround  DRIP1TLO, E236TLO, E336TLO & E460TLO  Life Shot FHD300 Portuguese manua  4月 - 製品安全協会  Ralspeed Hire Fleet BrochurePDF File, 2964 KB  Java Monitoring und Troubleshooting  Manuel d`utilisation  