1. Ramp triangle wave Frequency range 0 1 Hz to 200 kHz Linearity 1 Variable symmetry O to 100 symmetry resolution 1 Noise Bandwidth 20 MHz typical Sine Cardinal Sinc Frequency range 0 1 Hz to 1 0 MHz Exponential Rise Fall Frequency range 0 1 Hz to 5 0 MHz Cardiac Frequency range 0 1 Hz to 200 0 kHz Gaussian Pulse Frequency range 0 1 Hz to 5 0 MHz Arbitrary Waveform length 1 to 8k points Amplitude Resolution 10 bits including sign bit Repetition Rate 0 1Hz to 12 MHz Sample Rate 100 MSa s Filter Bandwidth 20 MHz 1 Full resolution is not available at output due to internal attenuator stepping 32 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics WaveGen Built in function arbitrary waveform generator specifications are typical continued Frequency Sine wave and ramp accuracy 130 ppm frequency lt 10 kHz 50 ppm frequency gt 10 kHz Square wave and pulse accuracy 50 frequency 200 ppm frequency lt 25 kHz 50 ppm frequency gt 25 kHz Resolution 0 1 Hz or 4 digits whichever is larger Amplitude Range 20 mVpp to 5 Vpp into Hi Z 10 mVpp to 2 5 Vpp into 50 Q Resolution 100 uV or 3 digits whichever is higher Accuracy 2 frequency 1 kHz DC offset Range 2 5 V into Hi Z 1 25 Vinto 500 Resolution 100 uV or 3 digits whichever is higher Accuracy waveform modes 1 5
2. Computer serial triggering and analysis RS232 UART DSOX3COMP 232 Sensor triggering and analysis SENT DSOXT3SENSOR SEN Automotive serial triggering and analysis CAN CAN FD CAN dbc LIN LIN symbolic DSOXT3AUTO AMS FlexRay serial triggering and analysis DSOX3FLEX FLX Audio serial triggering and analysis 125 DSOX3AUDIO SND MIL STD 1553 and ARINC 429 serial triggering and analysis Measurement applications WaveGen 20 MHz arbitary function generator DSOX3AERO AER DSOX3WAVEGEN 001 Integrated digital voltmeter and 8 digit counter DSOXT3DVMCTR DVM Power analysis application DSOX3PWR PWR Mask limit testing DSOX3MASK LMT Enhanced video TV application package Productivity tools Education and training kit DSOX8VID VID DSOXEDK EDK Infiniium Offline oscilloscope analysis software N3900A BenchVue for data capture Free Download 34840B version 2 6 and higher Vector signal analyzer software 89601B version 20 and higher Benchlink waveform builder pro and basic Application bundle 33903A DSOXT3APPBNDL include DSOX3AERO DSOX3AUDIO DSOXT3AUTO DSOX3COMP DSOXSEMBD DSOX3FLEX DSOX3MASK DSOX3PWR DSOXT3SENSOR DSOX3VID DSOX3WAVEGEN DSOXT3DVMCTR DSOXEDK These options are compatible with the 3000T X Series but are not compatible with the 3000A X Series 25 Keysight InfiniiVision 3000T X Se
3. of offset setting 1 of amplitude 1 mV Accuracy DC mode 1 5 of offset setting 3 mV Trigger output Trigger output available on Trig out BNC Main Output Impedance 50 Q typical Isolation not available main output BNC is grounded Protection overload automatically disables output Output mode Normal Single shot arbitrary sine ramp sine cardinal exp rise fall cardiac Gaussian pulse 1 Gaussian Pulse 4 Vpp maximum into Hi Z 2 Vpp maximum into 50 Q Digital voltmeter specifications are typical Functions ACrms DC DCrms Resolution ACV DCV 3 digits Measuring rate 100 times second Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements Range meter Graphical display of most recent measurement plus extrema over the previous 3 seconds Precision counter totalizer specification are typical Counter source Any analog channel or trigger qualified event Resolution 8 digits 8 digits for trigger qualified event Max frequency T GHz Trig qual events 1 trigger hold off time for trigger qualified events max 25 MHz minimum dead time of 40 ns Measurement Frequency period totalize Totalizer Counter size 64 bit totalizing counter Edge Rise or fall Gating Positive or negative level Select from analog channels except the source 33 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance
4. Built in function arbitrary waveform generator specifications are typical WaveGen out Front panel BNC connector Waveforms Sine Square Ramp Pulse DC Noise Sine Cardinal Sinc Exponential Rise Exponential Fall Cardiac Gaussian Pulse and Arbitrary Modulation Modulation types AM FM FSK Carrier waveforms sine ramp sine cardinal exponential rise exponential fall and cardiac Modulation source internal no external modulation capability AM Modulation sine square ramp Modulation frequency 1 Hz to 20 kHz Depth 0 to 100 FM Modulation sine Square ramp Modulation frequency 1 Hz to 20 kHz Minimum carrier frequency 10 Hz Deviation 1 Hz to carrier frequency or 2e12 carrier frequency whichever is smaller FSK Modulation 50 duty cycle square wave FSK rate 1 Hz to 20 kHz Hop frequency 2 x FSK rate to 10 MHz sine Frequency range 0 1 Hz to 20 MHz Amplitude flatness 0 5 dB relative to 1 kHz Harmonic distortion 40 dBc Spurious non harmonics 40 dBc Total harmonic distortion 1 SNR 50 Q load 500 MHz BW 40 dB Vpp gt 0 1 V 30 dB Vpp lt 0 1V Square wave pulse Frequency range 0 1 Hz to 10 MHz Duty cycle 20 to 80 Duty cycle resolution Larger of 1 or 10 ns Pulse width 20 ns minimum Rise fall time 18 ns 10 to 90 Pulse width resolution 10 ns or 5 digits whichever is larger Overshoot lt 2 Asymmetry at 50 DC 1 5 ns Jitter TIE RMS 500 ps
5. Snapshot All measure all single waveform measurements 31 Voltage peak to peak maximum minimum amplitude top base overshoot pre shoot average N cycles average full screen DC RMS N cycles DC RMS full screen AC RMS N cycles AC RMS full screen std deviation ratio N cycle ratio full screen Time period frequency counter width width burst width duty cycle duty cycle bit rate rise time fall time delay phase X at min Y X at max Y Count positive pulse count negative pulse count rising edge count falling edge count Mixed area N cycles area full screen Counter see pg 32 for 8 digit precision counter Waveform math Number of math functions Built in frequency counter Source on any analog or digital channel Resolution 5 digits Maximum frequency bandwidth of scope Two displays FFT and one math simultaneously Can be cascaded Arithmetic Add subtract multiply divide differentiate integrate FFT Ax B squared square root absolute value common logarithm natural logarithm exponential base 10 exponential low pass filter high pass filter averaged value smoothing envelope magnify max hold min hold measurement trend chart logic bus Timing or State Enhanced FFT Record size Up to 64 kpts resolution Window types Hanning Flat Top Rectangular Blackman Harris Time gated FFT Gate the time range of data for FFT analysis in the zoom view For time and
6. along with an integrated and localized help system Just hold any hard key or soft panel button and a brief overview will appear that explains how to use that feature 30 day trial license The 3000T X Series comes with a one time 30 day all optional features trial license You can choose to start the 30 day trial at any time In addition you can redeem individual optional feature 30 day trial licenses at any time by visiting www keysight com find 30daytrial This enables you to receive in effect 60 days of trial license of each optional feature Next generation probing All 3000T X Series come standard with a newly designed very robust 500 MHz 10 1 passive probe per channel In addition MSOs include a newly designed cable with a flexible cable management system that makes probing with the 16 digital channels easy gt Sax g Fe LOCALIZED GUI AND FRONT PANEL OPTIONS The 3000T X Series supports 15 different languages English Japanese Simplified Chinese Traditional Chinese Thai Korean German French Spanish Russian Portuguese talian Polish Czech Turkish 22 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet 6 in 1 instruments helps you solve your problems oscilloscope chan nels digital channels serial protocol analysis WaveGen DVM and 8 digit counter totalizer Fully upgradeable including bandwidth KEYSIGHT In
7. and lower total cost of ownership The only test and measurement company with three year warranty standard on all instruments worldwide Keysight Assurance Plans www keysight com find AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements www keysight com quality Keysight Technologies Inc DEKRA Certified ISO 9001 2008 Quality Management System Keysight Channel Partners www keysight com find channelpartners Get the best of both worlds Keysight s measurement expertise and product breadth combined with channel partner convenience www keysight com find 3000TX Series KEYSIGHT TECHNOLOGIES For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries Europe amp Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia spain Sweden Switzerland United Kingdom 877 894 4414 5911 3351 7010 001 800 254 2440 800 829 4444 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 421 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 8
8. inputting notes simple setups data and screenshots Redefine your remote Web control oscilloscope experience The 3000T X Series offers traditional control via a PC Web browser but also supports remote control through popular tablet devices when using the optional LAN VGA interface Figure 8 Remotely control the 3000T X Series via tablet device 04 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Discover The industry s fastest uncompromised update rate increases the chance of finding anomalies Industry Leading Uncompromised Update Rate If you can t see the problem you can t fix the problem With an industry leading update rate of over one million waveforms per second the InfiniiVision 3000T X Series gives you the highest probability of capturing random and infrequent events that you would miss on an oscilloscope with a lower waveform update rate Powered by MegaZoom IV smart memory technology the InfiniiVision 3000T X Series not only lets you see more waveforms but it has the uncompromised ability to find the most difficult problems in your design under any conditions Unlike other oscilloscopes uncompromised ability means Always fast responsive operation No slowdown with logic channels on No slowdown with protocol decoding on No slowdown with math functions on No slowdown with measurements on No slowdown with vectors on No slowdown with sinx x interpolation
9. of different serial decode and trigger options including long dead time Faster decoding with hardware based technology enhances the FC probability of capturing infrequent serial communication errors SPI 2 3 4 wire RS232 422 485 UART After capturing serial bus communication you can easily perform a search operation CAN based on specific criteria and then quickly navigate to bytes frames of serial data that CAN dbc satisfy that search criteria The 3000T X Series can decode two serial buses CAN FD simultaneously using hardware based decoding and display the captured data in a time LIN interleaved lister display LIN symbolic SENT Serial protocol decoding can be used simultaneously with segmented memory and FlexRay Zone touch triggering The 3000T X Series has the most decode trigger options in this MIL STD 1553 class of instrument including 12C SPI RS232 422 485 UART CAN CAN FD CAN dbc ARINC 429 LIN LIN symbolic SENT FlexRay MIL STD 1553 ARINC 429 and I S FS Sha T 3 PTEE Tee Y AR dr Wo sedi TEGO v r PEI dr IU LU STI Ce L Dr ULL T CO LALA mer pe LE lil iti fa Figure 15 I2C decode and Figure 16 RS232 decode Figure 17 CAN FD decode Figure 18 SPI 4wire Figure 19 Multi bus time trigger and trigger and trigger decode and trigger aligned decode solve Segmented smart memory combined with protocol analysis enables insights over long periods of time Se
10. seeing a glitch that happens 5 times a second while allowing the oscilloscope to acquire for 5 seconds With the 3000T X Series you maximize your chances of seeing the infrequent glitch With the competing scope if you are using any of the other features like measurements or search or digital channels the update rate slows considerably The only option you have in this case is to allow the oscilloscope to run longer For example if you are using digital channels you ll have to let the scope run over 8 000 times longer to get a similar probability to the uncompromised update rate of the 3000T X Series That s almost 12 hours of time versus 5 seconds 06 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet MegaZoom IV smart memory technology enables uncompromised update rate Traditionally CPU processing was the major bottleneck for oscilloscope waveform update rate and responsiveness Typically the CPU handles interpolations logic channel plotting serial bus decoding measurements and more and the waveform update rate drops dramatically as these features are turned on The InfiniiVision 3000T X Series requires minimum support from a CPU as most core operations are handled by Keysight proprietary technology the MegaZoom IV smart memory ASIC MegaZoom includes hardware serial decoders and hardware mask limit testing capability plots analog and digital data directly to the display supports GUI operation and integrates ad
11. this from the RF analog waveform as well lister 14 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet solve Standard advanced math capabilities allow new views of signals Advanced math analysis provides a variety of additional math functions and comes standard on the 3000T X Series Additionally math functions can be nested to provide additional insight into your designs You can create up to two math functions with one math function and FFT displayed at a time ADVANCED MATH The 3000T X Series supports up to two math functions with an assortment of operators transforms filters and visualizations Operators Add subtract multiply divide Transforms Differentiate integrate FFT E Squared square root Absolute value Common logarithm natural logarithm Exponential base 10 exponential Filters Low pass filter high pass filter Averaged value Smoothing Envelope Visualizations Magnify Max and min hold Measurement trend Chart logic bus timing chart logic bus state Solve Class leading measurements provide quick answers Automatic measurements are the essential tool of an oscilloscope In order to make quick and efficient measurements the 3000T X Series provides 3 powerful automatic measurements and can display up to 8 at a time Measurements can be gated by auto select main window zoom window or cursors and include full statistics MEASUREMENTS T
12. using the built in editor via touch and the large screen or by using Keysight s Benchlink Waveform Builder software www keysight com find 33503 1 1 504 2 3 0 0s Stop ce A 1 00 Y s 5 i Summary WaveGen 1 Arbitrary Waveform Editor ACQUISITON Normal Channels 10 0 1 10 0 1 WaveGen Edit Waveform Menu Create New Edit Existing Interpolate Source store Source AL JE D to Arb Figure 25 Optional arbitrary waveform generator provides easy access to stimulus The integrated arbitrary waveform generator makes capturing modifying and replaying signals simple t Integrated DVM Optional quick tester 3 digit digital voltmeter You can add an integrated 3 digit voltmeter part of the DSOXT3DVMCTR option to your 3000T X Series oscilloscope The voltmeter operates through the same probes as the oscilloscope channels However the DVM measurements are made independently from the oscilloscope acquisition and triggering system so you can make both the DVM and triggered oscilloscope waveform captures with the same connection The Counter E voltmeter results are always displayed keeping these quick gl characterization measurements at your fingertips 2 OO i MT Frequency i ESEA NO SU Figure 26 DVM and counter takes advantage of separate signal paths to provide measurements without a trigger while still using the scope probes 17 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet
13. 0 1 attenuation 1 per channel N2756A 16 digital channel MSO cable 1 per scope included on all MSO models and DSOXT3MSO Interface and built in help language support English Chinese simplified Chinese traditional Czech French German Italian Japanese Korean Portuguese Russian Spanish Polish Thai Turkish Documentation CD containing localized user s guide service guide and programmer s manual Localized power cord and overlay For MET CAL procedures click on the Cal Labs solutions link below http www callabsolutions com products Keysight These procedures are FREE to customers Related literature Publication title Publication type Publication number Serial Bus Applications for Keysight Infinii Vision 3000 X Series Oscilloscopes Data sheet 5990 6677EN Power Measurements for Keysight InfinilVision 3000 X Series oscilloscope Data sheet 5990 8869EN Mask Waveform Limit Testing For Keysight InfinilVision Series Data sheet 5990 3269EN Oscilloscopes Using an Oscilloscope Time Gated Fast Fourier Transforms for Time Correlated Mixed Domain Analysis Application note 5992 0244EN Keysight Infinii Vision 3000T X Series versus Danaher Tektronix MDO3000 Series Competitive 5992 0116EN Oscilloscopes comparison Keysight Infinii Vision 30007 X Series Oscilloscopes Product Fact Sheet Product fact sheet 5992 0150EN Triggering on Infrequent Anomalies and Complex Signals using Zone triggering Application note 5991
14. 0T X Series Oscilloscopes Data Sheet Performance characteristics Trigger system Trigger sources Analog channel 1 4 digital channel DO D15 line external WaveGen 1 or mod FM FSK Trigger modes Normal triggered requires trigger event for scope to trigger Auto triggers automatically in absence of trigger event Single triggers only once ona trigger event press Single again for scope to find another trigger event or press Run to trigger continuously in either Auto or Normal mode Force front panel button that forces a trigger Trigger coupling DC DC coupled trigger AC AC coupled trigger cutoff frequency lt 10 Hz internal lt 50 Hz external HF Reject High frequency reject cutoff frequency 50 kHz LF Reject Low frequency reject cutoff frequency 50 kHz Noise Reject Selectable OFF or ON decreases sensitivity 2x Trigger holdoff range 40 ns to 10 00 s Trigger sensitivity Internal lt 10 mV div greater of 1 div or 5 mV gt 10 mV div 0 6 div External 200 mVpp from DC to 100 MHz Trigger level range Any channel 350 mVpp 100 MHz to 200 MHz 6 div from center screen External 8V Trigger type selections Zone HW zone qualifier Trigger on user defined zones drawn on the display Applies to one analog channel at a time Specify zones as either must intersect or must not intersect Up to two zones gt 200 000 scans sec update rate Supported mod
15. 1107EN 35 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet License only bandwidth upgrades and measurement applications Keysight sales partner License Only Bandwidth Upgrade Models 3000T X Series Entitlement certificate Stick On USB drive containinge DSOXT3B1122 License only 100MHz to 200MHz upgrade 2ch DSOXT3B1124 License only 100MHz to 200MHz upgrade 4ch DSOXT3B3T52 License only 350MHz to 500MHz upgrade 2ch DSOXT3B3154 License only 350MHz to 500MHz upgrade 4ch Measurement Applications DSOX3AERO MIL STD 1553 amp ARINC 429 serial triggering amp analysis DSOX3AUDIO Audio serial triggering and analysis IS DSOXT3AUTO Automotive serial triggering and analysis CAN CAN FD LIN DSOX3COMP Computer serial triggering and analysis RS232 UART DSOX3EMBD Embedded serial triggering and analysis 1 C SPI DSOX3FLEX FlexRay serial triggering and analysis DSOX3MASK Mask Limit Testing DSOXT3MSO MSO upgrade add 16 digital timing channels N2756A MSO cable delivered separately DSOX3PWR Power analysis application DSOXT3SENSOR Single Edge Nibble Transmission SENT trigger and decode DSOX3VID Enhanced video TV application package DSOX3WAVEGEN WaveGen 20 MHz AWG DSOXT3DVMCTR Integrated digital voltmeter 8 digit counter DSOXEDK Education and training kit DSOXT3APPBNDL SW application bundle license for 3000T X Series label sheet O Keysight s
16. 30 g sine 11 ms duration 3 shocks axis along major axis total of 18 shocks Dimensions 381 mm 15 in W x 204 mm 8 in H x 142 mm 5 6 in D Weight Net 4 0 kg 9 0 lbs shipping 4 2 kg 9 2 lbs 34 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics Nonvolatile storage Reference waveform display Two internal waveforms or USB thumb drive Displays 1 reference waveform at atime Data file save Setup image Setup scp 8 or 24 bit Bitmap image bmp PNG 24 bit image png Waveform data CSV data csv ASCII XY data csv Binary data bin Lister data csv Reference waveform data h5 multi channel waveform data h5 Arbitrary Waveform data csv Application data Mask msk Power harmonics data csv USB signal quality html amp bmp Analysis results Cursor data measurement results mask test statistics search segmented timestamps csv Max USB flash drive size Supports industry standard flash drives Set ups without USB flash drive 10 internal setups Set ups with USB flash drive Limited by size of USB drive Included standard with oscilloscope Factory warranty 3 year warranty 90 days for unserialized accessories such as passive probes Calibration Certificate of calibration 3 year calibration interval Mean time before failure MTBF gt 250 000 hours Standard secure erase Probes N2843A Passive probe 500 MHz 1
17. 66 65 6375 8100 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 32 800 58580 0800 0233200 8800 5009286 0800 000154 0200 882255 0800 305353 Opt 1 DE Opt 2 FR Opt 3 IT 0800 0260637 For other unlisted countries www keysight com find contactus BP 07 10 14 This information is subject to change without notice Keysight Technologies 2014 2015 Published in USA February 04 2015 5992 0140EN www keysight com
18. Integrated frequency measurements Optional 8 digit counter and totalizer Traditional oscilloscope counter measurements offer only five or six digits of resolution which may not be enough for the most critical frequency measurements are being made With the 3000T X Series optional 8 digit counter part of the DSOXT3DVMCTR option you can see your measurements with the precision you would normally expect only from a standalone counter Because the integrated counter measures frequencies up to a wide bandwidth of 1 0 GHz you can use it for many high frequency applications as well The totalizer feature of the DSOXT3DVMCTR counter option adds another valuable capability to the oscilloscope It can count the number of events totalize and it also can monitor the number of trigger condition qualified events The trigger qualified events totalizer does not require an actual trigger to occur It only requires a trigger satisfying event to take place In other words the totalizer can monitor events faster than the trigger rate of a scope as fast as 25 million events per second a function of the oscilloscope s holdoff time which has the minimum of 40 ns Figures 27 shows example of a totalizer counting the number of CAN FD CRC delimiter bit error packets that took place in a design See www keysight com find DSOXDVMT3CTR for more information 20 00us 0 0s Trig d 2 Summary i Acquisition Normal 5 00GSa s Channels Counter Total
19. KEYSIGHT TECHNOLOGIES Keysight InfiniVision 30001 X Series Oscilloscopes Data Sheet AN KEYSIGHT Horizontal 02 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Touch Discover Solve The InfiniiVision 3000A X Series redefined oscilloscopes It saw the most signal detail provided more functionality than any other oscilloscope and gave you maximum investment protection It was also the most successful oscilloscope in Hewlett Packard Agilent and Keysight Technologies Inc s history The 3000T X Series continues that legacy The 3000T X Series takes everything that was revolutionary about the A model and adds a Capacitive touch screen a user interface designed for touch and the exclusive Zone touch trigger all combined with an industry leading uncompromised update rate of 1 million wfm s to give you the confidence that you re seeing all of your signal detail and the ability to discover any issues And the addition of new analysis capabilities help you solve your hardest problems quickly The 3000T X Series once again redefines what you can expect in a general purpose oscilloscope by providing all of the performance and capability you need to get to measurement insights faster pun 8 5 inch capacitive touch screen Designed for touch interface Discover Industry s fastest uncompromised waveform update rate Exclusive Infiniiscan Zone touch trigger Solve Wide rang
20. also offers a touch off button as well as USB mouse and keyboard support Figure 3 Side bar with movable docks allows Information to be placed on the screen precisely where you want it for documentation Touch interface simplifies documentation The availability of up to 4 annotations on screen makes it easy to highlight key items on screen shots Streamline documentation with the ability to input information via a pop up soft keyboard on the touch screen or a USB keyboard A sidebar displays additional information without covering the waveform graticule and allows you to dock and scroll through multiple measurement values Touch gestures like flicking make navigating lists or moving between segment waveforms easy In addition to the benefits of touch free BenchVue software provides documentation across multiple instruments at once USB LAN optional and GPIB optional connectivity make oscilloscope control or pulling data and screenshots easy And the Figure 4 Use BenchVue for remotely built in ability to send emails when connected to the LAN allows you to email yourself a logging and plotting measurement data screenshot or data file with just the press of a button Figure 5 See up to four annotations on screen Figure 6 With the optional LAN Figure 7 A dock able sidebar allows you to at once for documentation The standard touch VGA module you can email yourself customize how you view your measurements screen makes
21. ate Rate Probability Update Rate Probability Max w no features on 1 114 000 94 281 000 50 Max w digital ch on 1 101 000 94 132 0 03 Max w measurements on 1 114 000 94 2 200 0 55 Max w FFT on 1 114 000 94 2 200 0 55 Max w serial on 1 100 000 94 1 800 0 45 Max w search on 1 113 000 94 2 200 0 55 Max w ref wfms on 1 113 000 94 2 200 0 55 Table 1 Measured update rate between the 3000T X Series and the Danaher Tektronix MDO3000 Note how the update rate fluctuates wildly on the MDO3000 based on different settings features Why Is an uncompromised update rate important When debugging or troubleshooting a project it is important that you see as much signal detail as possible A fast update rate is just part of the overall equation to determine the likelinood of seeing an anomaly The frequency of the anomaly the timebase setting of the oscilloscope and the amount of time you allow the oscilloscope to see the anomaly all come in to play P 100 x 1 1 RW U where P Probability of capturing anomaly in t seconds t Observation time U Scope s measured waveform update rate R Anomalous event occurance rate W Display acquisition window Timebase setting x 10 Therefore it is important to select an oscilloscope with the fastest uncompromised update rate to allow enough time to increase your chances of seeing the glitch In Table 1 in addition to the measured update rate we show the probability of
22. ax Std Dey AC RMS F561 72 0396uV 1 764u 70 086u Y 73 501uV 473 46nV Pk Pk 1 572 90 68 87 502 5u 703 50 29 6630 Measurement Statistics Menu Display On Reset Relative o Max Count Statistics t Figure 12 High resolution mode allows you to lower your noise and increase your resolution up to 12 bits 50 Q 1 GHz Bandwidth Vrms measurement units mV Vertical setting Normal mode High resolution mode Notes 1 mV 0 227 0 072 Some scopes bandwidth automatically limited to 150 MHz 2 mV 0 277 0 072 Some scopes bandwidth automatically limited to 350 MHz 5 mV 0 297 0 081 Some scopes bandwidth automatically limited to 500 MHz 10 mV U 352 0 810 20 mV 0 997 0 102 50 mV 1 500 0 340 100 mV 2 560 0 480 200 mV 5 500 1 050 500 mV 15 200 3 630 1V 26 000 4 830 Table 2 Noise comparison between the normal and high resolution mode at 20 pu div 08 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Discover Industry exclusive zone touch trigger makes triggering simple An uncompromised update rate allows you to see an anomaly but to continue the debug process you have to isolate it Setting up a trigger has been a challenge since oscilloscopes introduced a triggered waveform While oscilloscopes have added more and more triggering capability over the years setting up triggers has remained complex at best and impossible at worst Zone touch trigger eliminates the complexity of
23. capabilities for peak searching max and min hold and averaging of FFTs to increase dynamic range When gated FFT is on the oscilloscope goes into zoom mode The FFT analysis shown in the zoomed bottom window is taken from the period of time indicated by the zoom box in the main top window In the gated FFT mode touch and flick the zoom box through the acquisition to investigate how the FFT analysis changes over time correlating the RF phenomenon with the analog and digital phenomenon Figure 21a through 21d show a simple gated FFT example observing a RF signal frequency transition from 400 MHz to 200 MHz time correlated to both the SPI controlling signal digital and a VCO enable signal analog Note you can also visualize the RF signal itself in the time domain to gain additional insight such as a gap in the RF time domain waveform ae eee j n ninni Acquisition Norral gt a Channels 5 e m n j il all s Ul TO RPR Y TI VII N pe pra P re aprirne Figure 21a Triggered on a SPI command the RF signal is still at 400 MHz as indicated in the frequency peak search result lister Acquisition Norma Channels Gated FFT result of 4 wiz tO 4 Mz trar rn Wind ertical Unas JOW Hannir b Decibels Window Vertical Units t Decibels Figure 21c Start observing the RF signal at 200 MHz You can validate Figure 21d RF signal settled down at 200 MH as indicated in the search
24. characteristics Connectivity Standard ports One USB 2 0 hi speed device port on rear panel Supports USBTMC protocol Two USB 2 0 hi speed host ports front and rear panel Supports memory devices printers and keyboards Optional ports GPIB LAN 10 100Base T WVGA video out Trigger out BNC connector on the rear panel Supported modes triggers mask and waveform generator sync pulse General and environmental characteristics Power line consumption Max 100 watts Power voltage range 100 120V 50 60 400 Hz 100 240V 50 60 Hz 10 auto ranging Temperature Operating 0 to 55 C Nonoperating 30 to 1 C Humidity Operating Up to 80 RH at or below 40 C up to 45 RH up to 50 C Non operating Up to 95 RH up to 40 C up to 45 RH up to 50 C Altitude Operating up to 4 000 m Non operating 15 300 m Electromagnetic compatibility Meets EMC Directive 2004 108 EC meets or exceeds IEC 61326 1 2005 EN 61326 1 2006 Group 1 Class A requirement CISPR 11 EN 55011 IEC 61000 4 2 EN 61000 4 2 IEC 61000 4 3 EN 61000 4 3 IEC 61000 4 4 EN 61000 4 4 IEC 61000 4 5 EN 61000 4 5 IEC 61000 4 6 EN 61000 4 6 IEC 61000 4 11 EN 61000 4 11 Canada ICES 001 2004 Australia New Zealand AS NZS Safety UL61010 1 2nd edition CAN CSA22 2 No 61010 1 04 Vibration Meets IEC60068 2 6 and MIL PRF 28800 class 3 random shock Meets IEC 60068 2 27 and MIL PRF 28800 class 3 random operating
25. dge 0 4 99725MH2z 21 2915dBY Pulse Width 6 99997 MHz 24 3140dBV coe Rise Fall Time 9 00269MHz l 26 8286dBV i Runt 10 9959MHz ie 28 9453dBV r Ae Frequency Peaks 12 9986MHz i 30 5103dBV serial 1 FC E 15 0013MHz 32 2021 dB Serial 2 FC Search Source Max Peaks Threshold Excursion Results Order Freq Peaks dal 11 49 0dBY 20 0dB Ampl Order Figure 14 The 3000T X Series was set up to capture clock signals for FFT analysis Using the search and navigation capability the scope was able to find mark white triangles and quickly navigate to the first 11 frequency peaks occurrences You can sort it in the order of frequency or amplitude CO o o Close up on buttons on the front panel of the scope Alternatively you also can use the touch navigation control earch events found 1 of 11 1 001 36MHz h 4580 1 g bu 12 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet solve Integrated hardware based serial decoding and triggering SERIAL DECODE AND option makes easy work of low speed serial buses TRIGGER OPTIONS Keysight InfiniiVision oscilloscopes including the new 3000T X Series use hardware based serial protocol decoding Some other vendors use software post processing techniques to decode serial packets frames and therefore have slow waveform and decode capture rates and could miss critical events and errors due to a The 3000T X Series supports a range
26. ditional instruments like the WaveGen function arbitrary waveform generator MegaZoom IV ASIC Hardware Accelerated Analog Measurements Signals _ Search gt ADC Acquisition 4 _ Memory si Manager a Segmented Memon Math 1 0 GUI r DRAM 16 Digital DRAM ou f Serial Decoders O Mask gt cn Synthesis Figure 11 The 3000T X Series oscilloscopes uncompromised responsiveness speed and waveform update rate are enabled by the MegaZoom IV smart memory ASIC The CPU is not used for core waveform operations 07 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Discover Excellent signal integrity allows you to see more signal detail The 3000T X Series has excellent signal integrity including full bandwidth to 1 mV div and the ability to get up to 12 bits of resolution using the high resolution acquisition mode Some oscilloscopes in this class limit their bandwidth at smaller volt per division set tings without on display user notifications This is likely to keep the noise acceptable at lower volt per division settings Table 2 shows a comparison of the typical noise floor at 20 u div between the normal and high resolution mode You will notice that the noise floor performance improves as much as five times mrm AT 0 04 A Summary E Acquisition High Resolution 5 00GSa s 0 0s Auto Channels Meas AC RMS FS 1 Measure Current Min M
27. e of serial decodes 6 in 1 instrument integration Time frequency domain correlation Ww KEYSIGHT InfiniiVision DSO X 3104T Digital Storage Oscilloscope 1GHz 5GSa s Figure 1 InfiniiVision 3000 X Series with MagaZoom IV smart memory technology 03 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Touch Designed for touch interface and capacitive touch screen simplify use From the start of product development we designed every aspect of this oscilloscope to be seamlessly driven by a touch interface Large easy to touch targets a graphical user interface that adapts to show you more and be easier to touch and a large Sensitive capacitive touch screen all combine to make operation quick and natural just like your favorite tablet devices Figure 2 The industry s first 8 5 capacitive ui o touch display with large touchable targets Capacitive touch screen technology enables productivity The user interface allows you to use the alphanumeric pad for quick annotation place waveforms or cursors in exact positions and drag docking panels across the screen to see more measurement information The 3000T X Series offers three ways to access key menus and features touch GUI for those that prefer tablet or smart phone touch interfaces front panel buttons and knobs for the traditional oscilloscope users and Keysight Insight pull down menu for users who prefer Windows like operations The 3000T X Series
28. emely low cost of ownership Between the standard 3yr warranty an industry leading mean time between failure MTBF of over 250 000 hours and a market leading calibration period of 3 years you can rest assured that your investment in a 3000T X Series will be protected for years to come In addition because needs change over time you can purchase just what you need today and then upgrade the scope s bandwidth or measurement application easily over time as your projects evolve Educator and Training Kit Have new hires that need to quickly become familiar with the scope Or are you a professor that wants to teach your students what an oscilloscope is and how to perform basic measurements The optional Educator s Oscilloscope Training Kit DSOXEDK makes that easy It includes training tools created specifically for electrical engineering and physics undergraduate students and professors It contains an array of built in training signals a comprehensive oscilloscope lab guide and tutorial written specifically for the undergraduate student and an oscilloscope fundamentals PowerPoint Slide set for professors and lab assistants For more information refer to www keysight com find EDK 21 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Built in features to help the infrequent user In addition to the optional educator s training kit the oscilloscope Includes a localized front panel and GUI available in 15 languages
29. es normal peak detect high resolution Also works simultaneously with the serial trigger and mask limit test Edge Edge then edge B trigger Trigger on a rising falling alternating or either edge of any source Arm on a selected edge wait a specified time then trigger on a specified count of another selected edge Pulse width Trigger on a pulse on a selected channel whose time duration is less than a value greater than a value or inside a time range Minimum duration setting 2 ns 500 MHz 1 GHz 4 ns 350 MHz 6 ns 200 MHz 10 ns 100 MHz Maximum duration setting 10 s Range minimum 10 ns Runt Trigger on a position runt pulse that fails to exceed a high level threshold Trigger on a negative runt pulse that fails to exceed a low level threshold Trigger on either polarity runt pulse based on two threshold settings Runt triggering can also be time qualified lt or gt with a minimum time setting of 2 10 ns and maximum timesetting of 10s Minimum time setting 2 ns 500 MHz 1 GHz 4 ns 350 MHz 6 ns 200 MHz 10 ns 100 MHz Setup and hold Trigger and clock data setup and or hold time violation Setup time can be set from 7 s to 10 s Hold time can be set from Os to 10 ns Rise fall time Trigger on rise time or fall time edge speed violations lt or gt based on user selectable threshold Select from lt or gt and time settings range between Minimum 1 ns 500 MHz 1 GHz 2
30. eshold setting Maximum input dynamic range 10 V about threshold Minimum voltage swing 500 mVpp Input impedance 100 kQ 2 at probe tip Input capacitance 8 pF Vertical resolution 1 bit 1 Denotes warranted specifications all others are typical 2 Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 1 mV div and 2 mV div are a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 1 mV div and 2 mV div sensitivity setting 27 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics 3000T X Series specification overview 30127 3014T 30227 3024T 3032T 3034T 3052T 3054T 3102T 3104A Time base range 5 ns div to 50 s div 2 ns div to 50 s div 1 ns div to 50 s div 500 ps div to 50 s div Time base accuracy 1 6 ppm aging factor 1st year 0 5 ppm 2nd year 0 7 ppm 5 years 1 5 ppm 10 years 2 0 ppm Time base delay Pre trigger Greater of 1 screen width or 250 us time range Post trigger 1sto500s Channel to channel deskew range sa A Time accuracy time base acc x reading 0 0016 x screen width 100 ps using cursors Modes Main zoom roll XY XY On channels 1 and 2 only Z Blanking on Ext Trigger Input 1 4 V threshold Bandwidth Maximum bandwidth Phase error at 1 MHz lt 0 5 degree Horizontal System Digital Channels Minimum d
31. etectable pulse width ons Channel to channel skew 2 ns typical 3 ns maximum Acquisition System Maximum analog channels sample bee 5 GSa s half channel interleaved 2 5 GSa s all channel Maximum analog channels record 4 Mpts half channel interleaved 2 Mpts all channel length Maximum digital channels sample 1 25 GSa s all pods rate Maximum digital channels record 2 Mots with digital channels only length Acquisition mode Normal Default mode Peak detect Capture glitches as narrow as 250 ps at all time base settings Averaging selectable from 2 4 8 16 64 to 65 536 High Real time boxcar averaging reduces random noise and effectively increases vertical resolution resolution 12 bits of resolution when 2 10 us div at 5 GSa s or gt 20 us div at 2 5 GSa s segmented Segmented memory optimizes available memory for data streams that have long dead times between activity Maximum segments 1000 Re arm time 1 us minimum time between trigger events Time mode Normal Default mode Roll Displays the waveform moving across the screen from right to left Available at the time base 50 ms div or slower XY Displays the volts versus volts display Time base can be set from 200 ns div to 50 ms div 1 Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 28 Keysight InfiniiVision 300
32. eysight Service Center Bandwidth Upgrades Keysight sales partner Return to Keysight Bandwidth Upgrade Models 3000T X Series DSOXT3B1132U Service center JOOMHz to 350MHz upgrade 2ch DSOXT3B1T52U service center JOOMHz to 500MHz upgrade 2ch DSOXT3B1T102U Service center 100MHz to 1 GHz upgrade 2ch DSOXT3B1T34U Service center 100MHz to 350MHz upgrade 4ch DSOXT3B1T54U service center 100MHz to 500MHz upgrade 4ch DSOXT3B1T104U Service center 100MHz to 1 GHz upgrade 4ch DSOXT3B2132U service center 200MHz to 350MHz upgrade 2ch DSOXT3B2152U Service center 200MHz to 500MHz upgrade 2ch DSOXT3B21102U service center 200MHz to 1 GHz upgrade 2ch DSOXT3B2T34U Service center 200MHz to 350MHz upgrade 4ch DSOXT3B27154U Service center 200MHz to 500MHz upgrade 4ch DSOXT3B2T104U Service center 200MHz to 1 GHz upgrade 4ch DSOXT3B3T102U Service center 350MHz to 1 GHz upgrade 2ch DSOXT3B31104U Service center 350MHz to 1 GHz upgrade 4ch DSOXT3B51102U Service center 500MHz to 1 GHz upgrade 2ch DSOXT3B5T104U Service center 500MHz to 1 GHz upgrade 4ch Keysight Business Center Ship scope per Keysight service center Customer Upgraded scope shipped back 7 2 3 a a Place order for a return to Keysight Service Center bandwidth upgrade product to a Keysight sales partner Shipment costs are in addition to bandwidth upgrade product price Keysight Business Center will contact you rega
33. finiiVision MSO X 3104T Mixed Signal Oscilloscope 1GHr GSa s Designed for Touch 8 5 inch capacitive touch screen with 1 007 2 00s 70 COs gesture support i T a Frequency Lie 1889 lt 3 58 50 Fi DO BW 100 1 DC BW T a Uncompromised 1 000 000 waveform per second update rate minimize Integrated DVM and 8 digit counter with totalizer Wide coverage the dead time for maximum probability of capturing infrequent events of application and serial protocol solutions including CAN FD and and anomalies SENT trigger and decode Built in features to help the infrequent user GUI available in 15 Both USB keyboard and mouse are Supported in 3000T X Series for languages additional ease of use Display up to 8 measurements Standard segment memory with event lister powered by simultaneously without compromising other key info 38 automatic MegaZoom IV smart memory technology intelligent capture of just measurements Gated by cursors supported the signals of interest 23 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Reconfigurable Docking panels with Zone touch trigger if you Standard advanced math displays the capacitive touch screen adds a can see it you can trigger FFT and one math functions for new dimension to the usability on it by drawing a box your deep analysis Run Contrgi Standard Gated FFT for your time correlated analog digital and frequency domain signal a
34. frequency domain correlated analysis Waveforms FFT max hold min hold average Peak search Max 11 peaks threshold and excursion control Search navigate and lister Type Edge pulse width rise fall runt frequency peak serial bus 1 serial bus 2 Copy Copy to trigger copy from trigger Frequency peak Source Math functions Max ofpeaks 11 Control Results order in frequency or amplitude Result display Display characteristics Event lister or navigation Manual or auto scroll via navigation or touch event lister entry to jump to a specific event Display 8 5 inch capacitive touch gesture enabled display Resolution 800 H x 480 V pixel format screen area Graticules 8 vertical divisions by 10 horizontal divisions with intensity controls Format YT XY and Roll Maximum waveform update rate gt 1 000 000 wfms s Persistence Off infinite variable persistence 100 ms 60 s Intensity gradation 64 intensity levels Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature sensitivity setting 1 mV div and 2 mV div is a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 1 mV div and 2 mV div 31 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics WaveGen
35. gmented memory works In conjunction with any of the optional serial protocol decodes For example by setting the trigger condition to SENT serial bus error segmented memory captures and stores only SENT pulse period error packets and stitches together each segment for easy viewing of the decoded data in the lister You can quickly compare time tags to discover time intervals between errors 500m 0 0s Stop Serial 1 SENT Xt Time S amp C ID Data CRC Errors 2 369ms ago si i s4zk 52 00 FP aS psms 830 982ms rese e DR L____ 102088 esa SOS 036078 rss se C 1224518 ss JT ER 1 426605 1 443245 1 63268s 1 647325 Segments 1 85141s 2 04085s 2 05549s 2 244945 2 20958s 2 44902s segment 19 of 25 1 53677s segment 1 Time 2014 10 24 10 01 45 segmented Current Seg of Segs Analyze 19 25 segments t Show Table Figure 20 Segmented memory being used in conjunction with SENT bus serial decode resulting in maximum insight to the serial bus 13 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Viewing the frequency content of waveforms is greatly simplified by a dedicated FFT button and level adjustment knobs Pop up keypads make inputting start stop Soan and center frequency easy And the new problem solving feature called gated FFT unique in this class of instrument lets you time correlate the analog digital and frequency domain to aid in analysis and debug In addition there are new
36. h to be equal to the pulse width that was measured 10 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Acquisition memory size is an essential oscilloscope specification because it determines sustainable sample rate and the amount of time you can capture In a single acquisition In general longer memory is better However no memory will always be long enough to capture all the signals you need especially when capturing infrequent anomalies data bursts or multiple serial bus packets Segmented memory acquisition lets you selectively capture and store important signal activity without capturing unimportant signal idle time In addition it provides a time stamp of each segment relative to the first trigger event to enable analysis of the frequency of the event Segmented memory comes standard on the 3000T X Series Figure 13 shows segmented memory successfully capturing 100 small and large glitch events at 5 GSa s in 47 seconds Traditional memory architecture would require almost 203 Gpts of memory to accomplish the same result This memory is not available on any scope in the market Segments 100 of 100 43 6549s IC Furthermore segmented memory discovered that the worst offender glitch happened 40 seconds from the first trigger event or at the 95th glitch It also found out a unique glitch took place 13 seconds after the first glitch As shown in figure 13a you can overlay all segments to have a compre
37. he 3000T X Series supports 38 automated measurements Voltage Peak to peak maximum minimum amplitude top base overshoot pre shoot average N cycles average full screen DC RMS N cycles DC RMS full screen AC RMS N cycles AC RMS full screen standard deviation ratio N cycles ratio full screen Time Period frequency counter width width burst width duty cycle bit rate rise time fall time delay phase X at min Y X at max Y Count Positive pulse count negative pulse count rising edge count falling edge count Mixed Area N cycles area full screen Counter Built in frequency counter 15 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Solve 6 in 1 integration allows new measurement possibilities In addition to the class leading oscilloscope and powerful serial protocol analysis capabilities the 3000T X Series offers four additional integrated instrument capabilities not always found in this class of oscilloscope Integrated mixed signal oscilloscope MSO optional The 3000T X Series offers 16 optional integrated and upgradable digital channels Digital content is everywhere in today s designs and traditional 2 and 4 channel oscilloscopes do not always provide enough channels for the job at hand With an additional 16 integrated digital channels you now have up to 20 channels of time correlated acquisition and viewing on the same instrument In addition t
38. hensive view as well 1 1 007 4 20 00ns 0 0s Stop Ii El 2 Summary Segment 95 100 Channels DC 10 0 1 Segments z 23 f 0045 40 4066s 40 5179s 42 6479s 42 9367s 42 9873s Segment 1 Time 2014 10 24 01 45 22 Current Seg S Analyze HA O00 Segments Segment 95 of 100 40 5179s Segmented Show Table Figure 13a Screen showing an overlay of all 100 segments for worst case waveform analysis Segments 95 of 100 40 5179s Figure 13 Segmented memory reveals different types of glitches are taking place 11 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Discover Dedicated search and navigation helps you navigate deep memory Parametric and serial bus search and navigation comes standard on the 3000T X Series oscilloscopes When you are capturing long complex waveforms using an oscilloscope s acquisition memory manually scrolling through stored waveform data to find specific events of interest can be slow and cumbersome With automatic search and navigation capability you can easily set up specific search criteria and then quickly navigate to found and marked events Available search criteria include edges pulse width time qualified rise fall times time qualified runt pulses time and level qualified frequency peaks FFT function threshold and excursion qualified and serial bus frames packets and errors 150m 0 0s Auto E Search 3 00407 MHz 16 8457 dBY E
39. ize Trigger Menu Trigger Type Trigger on Filter by ID 51 CAN CRC Delimiter Bit t Figure 27 Totalizer counts the number of events In addition it can count the number of trigger condition qualified events as fast as 25 million events a second 18 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Whether you are performing pass fail tests to specified standards in manufacturing or testing for infrequent signal anomalies mask limit testing can be a valuable productivity tool DSOX3MASK The 3000T X Series features powerful hardware based mask testing that can perform up to 270 000 tests per second You can select multiple test criteria including the ability to run tests for a specific number of acquisitions a specified time or until detection of a failure See www keysight com find DSOX3MASK for more information 490mV 20 00ns 40 00ns Auto 1 i Summary Acquisition hinge 5 00GSa s Channels DC 10 0 1 Current Mask Eye of Tests Fa Channel 2 40 067k status Failing 0 4168 Analyze Menu Features Statistics Setup Automask Li Mask y mi y Figure 28 Hardware accelerated mask testing allows testing against a golden waveform or user created mask to find violations In this example we captured over 5M tests in only 30 seconds When you are working with switching power supplies and power devices the power measurements application DSOX3PWR provides a full suite of power meas
40. ling AC DC Input impedance Selectable 1 MQ 1 14 pF 50 Q 1 5 Input sensitivity range 100 MHz 500 MHz models 1 mV div to 5 V div 1 MQ and 50 Q 1 GHz models 1 mV div to 5 V div 1 MQ 1 mV div to 1 V div 50 Q Vertical resolution 8 bits measurement resolution is 12 bits with averaging Maximum input voltage 300 Vrms 400 Vpk transient overvoltage 1 6 kVpk With N2843A 10 1 probe 300 Vrms Frequency de rating assumes sine wave input 400 Vpk until 40 kHz Then de rates at 20 db dec until 6 Vpk DC vertical accuracy DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale DC vertical gain accuracy DC vertical offset accuracy 2 0 full scale 0 1 div 2 mV 1 of offset setting Channel to channel isolation gt 100 1 from DC to maximum specified bandwidth of each model measured with same V div and coupling on channels Offset range Vertical system digital channels Digital input channels 2 V 1 mV div to 200 mV div 50 V gt 200 mV div to 5 V div 16 digital DO to D15 pod 1 D7 DO Pod 2 D15 D8 Thresholds Threshold per pod Threshold selections TTL 1 4 V 5V CMOS 2 5 V ECL 1 3 V user defined selectable by pod User defined threshold range 8 0 Vin 10 mV steps Maximum input voltage 40 V peak CAT transient overvoltage 800 Vpk Threshold accuracy 100 mV 3 of thr
41. nalysis Pulse Width 159 56080008 19155180005 6 Independent knobs per channel for fast operation All front panel knobs are push able for access to common controls m5 000kHz Not a touch screen fan Turn off the touch screen from a front panel button AutoProbe interface supports various Build in WaveGen function arbitrary active differential and current probes generator allows you to capture and regenerate the signals immediately 24 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Configuration Step 1 Choose your bandwidth and number of channels 3000 X Series specification overview 3012T 3014T 3022T 3024T 3032T 3034T 3052T 3054T 3102T 3104T Bandwidth 3dB 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz Calculated rise time 10 90 Soans lt 1 75 ns lt 1 ns lt 700 ps lt 450 ps Input channels DSOX 2 4 2 4 2 4 Z 4 2 4 MSOX 216 4 16 2416 4 16 2 16 4 16 2416 4 16 2416 44716 1 For example if you chose 1 GHz 4 16 channels the model number will be MSOX3104T Step 2 Tailor your oscilloscope with integrated capabilities and measurement applications to save time and money After purchase upgrade model numbers are listed below values in parentheses are factory installed option numbers Description Oscilloscope features Model number MSO upgrade Serial protocols Embedded serial triggering and analysis 12C SPI DSOXT3MSO DSOX3EMBD LSS
42. ns 350 MHz 3 ns 200 MHz 5 ns 100 MHz Maximum 10 s Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 29 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics Trigger type selections N edge burst Trigger on the Nth 1 to 65535 edge of a pulse burst Specify idle time 10 ns to 10 s for framing Pattern Trigger when a specified pattern of high low and don t care levels on any combination of analog digital or trigger channels is entered exited Pattern must have stabilized for a minimum of 2 ns to qualify as a valid trigger condition Minimum duration setting 2 ns 500 MHz 1 GHz 4 ns 350 MHz 6 ns 200 MHz 10 ns 100 MHz Maximum duration setting 10 s Range minimum 10 ns Or Trigger on any selected edge across multiple analog or digital channels Video Trigger on all lines or individual lines odd even or all fields from composite video or broadcast standards NTSC PAL SECAM PAM M Enhanced Video optional Trigger on lines and fields of enhanced and HDTV standards 480p 60 567p 50 720p 50 720p 60 1080p 24 1080p 25 1080p 30 1080p 50 1080p 60 1080i 50 10801 60 USB Trigger on start of packet end of packet reset complete enter suspend or exit suspend Support USB low speed and full speed 1 C optional Trigger at a sta
43. o offering powerful triggering across the analog and digital channels this also gives you additional channels to use for serial decode and triggering And if you buy a 2 or 4 channel DSO you can upgrade it at any time to an MSO with a software license 1 620m 2 200m Memo Mode Default ta Exit 20 00Us 0 0s Auto Pat 1 500m i Summary i Acquisition lacn 10 01 10 0 1 2 13 AM 10 0 1 DC 10 0 1 Di I Aug 16 2014 PETES BRIKI AOS a DE Figure 24 Optional digital channels allow a timing view of up to 16 channels Tightly integrated they work with the analog triggers and serial triggers decoding 16 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Integrated WaveGen Built in 20 MHz function arbitrary waveform generator optional The 3000T X Series offers an integrated 20 MHz function arbitrary waveform generator available with modulation support DSOX3WAVEGEN The function generator provides stimulus output of sine square ramp pulse DC Sinc x exponential rise fall cardiac Gaussian Pulse and noise waveforms to your device under test The modulation feature supports AM FM and FSK modulations with modulation shapes of sine square and ramp The generator can output a continuous or a single shot waveform With AWG functionality you can store waveforms from analog channels or reference memory to the arbitrary memory and output from WaveGen Then easily create or edit the waveform
44. oftware _ licensing website Customer Email containing attached licensed file license file oi 1 Place order for a license only bandwidth upgrade or measurement application product to a Keysight sales partner If multiple bandwidth upgrade steps are needed order all the corresponding upgrade products required to get from current bandwidth to desired bandwidth 2 For measurement applications you will receive a paper or electronic pdf Entitlement Certificate For bandwidth upgrades only you will receive a stick on label document indicating upgraded bandwidth specification in addition to a paper Entitlement Certificate 3 Use Entitlement Certificate containing instructions and certificate number needed to generate a license file for a particular 3000T X Series oscilloscope model number and serial number unit 4 Receive the licensed file and installation instructions via email 5 Copy license file lic extension from email to a USB drive and follow instructions in email to install the purchased bandwidth upgrade or measurement application on the oscilloscope 6 For bandwidth upgrades only attach bandwidth upgraded stick on label to front and rear panels of the oscilloscope Model number and serial number of the oscilloscope do not change See next page for return to Keysight service center upgrade process for these products 36 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Return to K
45. on What is waveform update rate As oscilloscopes acquire data process it and plot it to the screen there is inevitable dead time or the time oscilloscopes miss signals completely In general the faster the waveform update rate the shorter the dead time The shorter the dead time the more likely an oscilloscope is to capture anomalies and infrequent events This is why it is important to select an oscilloscope with a fast waveform update rate Figures 7 and 8 demonstrate the difference between a slower update rate and a faster update rate Ye o x Figure 9 Other vendor s oscilloscope with 50 000 waveforms second A long dead time decreases your chances of capturing infrequent events Figure 10 InfiniiVision 30000T X Series with 1 000 000 waveforms second A short dead time increases your chancs of capturing infrequent events 05 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet But all specs aren t equal Many vendors claim an update rate specification but that is only in a special mode or without any features turned on Table 1 shows the 3000T X Series update rate versus a competing oscilloscope While all scopes update rate will vary to some degree by the timebase setting it is critical that the update rate remain constant regardless of the functionality you are using within the oscilloscope 10 ns div Keysight Tektronix 3000T X Series MD03000 Series Upd
46. r checksum error frame symbolic frame and signal symbolic Trigger on frame ID frame type sync start up null normal cycle repetitive cycle base and errors MIL STD 1553 optional Trigger on MIL STD 1553 signals based on word type Data or Command Status Remote Terminal Address data and errors parity sync Manchester encoding ARINC 429 optional SENT optiional Trigger and decode on ARINC429 data Trigger on word start stop label label bits label range error conditions parity word gap word or gap all all bits eye all O bits all 1 bits Trigger and decode on SENT bus start of fast channel message start of slow channel message fast channel SC amp data slow channel message ID slow channel message ID amp data tolerance violation fast channel CRC error slow channel CRC error all CRC errors pulse period error successive sync pulses error 1 64 30 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics Waveform measurements Cursors Single cursor accuracy DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale Dual cursor accuracy DC vertical gain accuracy 0 5 full scale Units Seconds s Hz 1 s Phase degrees Ratio Automatic measurements Measurements continuously updated with statistics Cursors track last selected measurement Select up to eight measurements from the list below
47. rail noise ripple and transients measurements can be challenging due to required offset range and mV sensitivity With its 24 V offset range ultra low noise 1 1 attenuation ratio and 2 GHz bandwidth the N 020A power rail probe is for users making critical power integrity measurements that need mV sensitivity on their DC power rails 1 000us 0 0s Acquisition Hi g h Resolution 5 00GSa s Channels Figure 30a 3000T X Series and N7020A acquire not only the power rail Figure 30b N7020A Power Rail Probe ripples but the high frequency transients as well Solve Video analysis option Whether you are debugging consumer electronics with HDTV or characterizing a design the HDTV measurement application DSOX3VID provides support for a variety of HDTV standards for triggering and analysis See www keysight com find DSOXSVID for more information D i 2 Demo Made Default to Ex 5 000ms 0 0s Trig d E l i Summary Channels 1 00 1 10 031 123 375mV 0 0V 41250m DE j 11 26 PM 1 00 1 DE 10 0 1 Aug 18 2014 ui DE Figure 31 20 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet While the Touch Discover Solve elements of the scope highlight the key features that will make it easy to debug and troubleshoot your device there are other features that you may also want to consider when choosing your next oscilloscope Total cost of ownership The 3000T X Series offers an extr
48. rding process and timing of the Service Center installation Continue to use oscilloscope until contacted again later when parts are available at Service Center Ship the oscilloscope per provided instructions to Service Center Service Center ships back upgraded oscilloscope with stick on labels applied to front and rear panels indicating upgraded bandwidth specification Model number and serial number of the oscilloscope do not change 37 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet myKeysight AXio LAI myKeysight www keysight com find mykeysight A personalized view into the information most relevant to you www axiestandard org AdvancedTCA Extensions for Instrumentation and Test AXle is an open standard that extends the AdvancedTCA for general purpose and semiconductor test Keysight is a founding member of the AXle consortium ATCA AdvancedTCA and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group www lxistandard org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems Keysight is a founding member of the LXI consortium www pxisa org PCI eXtensions for Instrumentation PXI modular instrumentation delivers a rugged PC based high performance measurement and automation system Three Year Warranty www keysight com find ThreeYearWarranty Keysight s commitment to superior product quality
49. ries Oscilloscopes Data Sheet Configuration Step 3 Choose your probes For a complete list of compatible probes visit www keysight com find scope_probes In general the 3000T X Series supports up to two active probes simultaneously with some exceptions Contact Keysight for more detail Probes N2843A Passive probe 500 MHz 10 1 1 MQ 11 pF Standard 1 per channel N2756A 16 digital channel MSO cable standard on MSOX models amp DSOXT3MSO N28 0A Passive probe 35 MHz 1 1 1 MQ Optional 10076C Passive probe 500 MHz 100 1 attenuation 4kV Optional N2804A 300 MHz 100 1 Differential probe 4 MQ 4 pF 300V DC peakAC Optional N2805A 200 MHz 100 1 Differential probe 4 MQ 4 pF 100V 5 m cable Optional N2790A 100 MHz 50 1 500 1 High voltage differential probe 8 MQ 3 5 pF 1 400 V Optional N2795A Active single ended probe 1 GHz 1 pF 1 MQ with AutoProbe Optional N2797A Active single ended probe 1 5 GHz extreme temperature Optional N2750A InfiniiMode differential probe 1 5 GHz 700 fF 200 kQ with AutoProbe Optional N2790A Differential active probe 100 MHz 1 4 kV with auto probe Optional N2791A Differential active probe 25 MHz 00 V Optional N2818A 200 MHz 10 1 Differential Probe with AutoProbe Optional N2819A 800 MHz 10 1 Differential Probe with AutoProbe Optional 1147B AC DC current probe 50 MHz 15 A with auto probe Optional N2893A AC DC current probe 100 MHz 15 A with auto probe Op
50. rt stop condition or user defined frame with address and or data values Also trigger on missing acknowledge address with no accq restart EEPROM read and 10 bit write SPI optional Trigger on SPI Serial Peripherial Interface data pattern during a specific framing period Supports positive and negative Chip Select framing as well as clock Idle framing and user specified number of bits per frame Supports MOSI and MISO data RS 232 422 485 UART optional Trigger on Rx or Tx start bit stop bit or data content or parity error 2S optional Trigger on 2 s complement data of audio left channel or right channel lt gt gt lt lt gt increasing value or decreasing value CAN optional Trigger on CAN controller area network version 2 0A 2 0B and CAN FD Flexible Data rate signals Trigger on the start of frame SOF the end of frame EOF data frame ID data frame ID and data non FD data frame ID and data FD remote frame ID remote or data frame ID error frame acknowledge error from error stuff error CRC error spec error ack or form or stuff or CRC all errors BRS Bit FD CRC delimiter bit FD ESI bit active FD ESI bit passive FD overload frame message message and signal non FD message and signal FD first 8 bytes only LIN optional FlexRay optional Trigger on LIN Local Interconnect Network sync break sync frame ID or frame ID and data parity erro
51. scopes Data Sheet steps to trigger on a runt signal 3000T X Series lc DI Sh Draw box on the runt Select must intersect Draw a second box if needed to further isolate the runt from other runts Select must intersect or must not intersect In some cases you may have to select the appropriate source if it wasn t already selected Cancel Horizontal Waveform Zoom brma Waveform Zoom Zone 1 Must Intersect Zone 1 Must Not Intersect Zone 2 Must Intersect Zone 2 Must Not Intersect zS Add Annotation Zone Logic Zone 1 T Zone 1 On Zone 2 On Zone 2 Intersect Zone 1 Intersect Source Traditional Scopes with Advanced Triggers assuming the update rate is fast enough to see what you want to trigger on OOND N Determine what trigger makes the most sense for the signal you are trying to isolate In this case we ll use a runt trigger first Select trigger menu Press trigger type Select runt Trigger Select your source Select the runt s polarity Adjust your low threshold to below the runt Adjust your high threshold to above the runt Select when you ll trigger in this case we want to trigger on the exact pulse width of the runt Select cursors Move cursor a to the rising edge of the pulse at the 50 mark Move cursor b to the falling edge of the pulse at the 50 mark Obtain the delta time pulse width between the cursors Adjust the runt widt
52. setting up advanced triggers Now if you can see the event on the display of the oscilloscope you can trigger on it just by drawing a box on the signal you want to isolate See how easy Zone touch triggering can be with these examples Steps to isolate a non monotonic edge Traditional Scopes with Advanced Triggers 3000T X Series assuming the update rate is fast enough to see 1 Draw box on non monotonic edge what you want to trigger on 2 Select must intersect 1 Determine what trigger makes the most sense for the In some cases you may have to select the appropriate source signal you are trying to isolate In this case we ll try a if it wasn t already selected rise time trigger first 2 Select cursors 3 Move cursor ato 10 level Cancel 4 Move cursor b to 90 level on the non monotonic edge ae 5 Obtain the delta time rise time between the cursors aie 6 Select trigger menu SS a 7 Press trigger type Zone 1 Must Intersect 8 Select Rise Fall time Trigger Zone 1 Must Not Intersect 9 Select your source Zone 2 Must Intersect 10 Select your slope Zone 2 Must Not Intersect 11 Select when you want it to trigger is it less than rare greater than equal to not equal to We ll select greater than 12 Dial in the greater than setting to the measured rise time 13 Adjust your low threshold to the 10 level 14 Adjust your high threshold to the 90 level 09 Keysight InfiniiVision 3000T X Series Oscillo
53. tional N2820A 2 channel high sensitivity current probe 50 uA 5A Optional N2821A channel high sensitivity current probe 50 uA 5A Optional N7020A Power Rail Probe 2 GHz 1 1 24V offset range at 500 Optional otep 4 Add the final touches Recommended accessories DSOXLAN LAN VGA connection module Optional DSOXGPIB GPIB connection module Optional N2747A Front panel cover Optional N6456A Rack mount kit Optional N6457A soft carrying case with front panel cover Optional Hard transit case CaseCruzer 3F1112 1510J Optional available from http www casecruzer com 26 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Performance characteristics DSO and MSO 3000 X Series oscilloscopes 3000T X Series specification overview 30127 3014T 3022T 3024T 3032T 3034T 3052T 3054T 31027 31047 Bandwidth 3dB 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz Calculated rise time 10 90 lt d9 ns lt 1 75 ns lt 1ns lt 700 ps lt 450 ps DSOX 2 4 Z 4 7 4 2 4 2 4 Input channels MSOX 2 16 4 16 2 16 4 16 2 16 4 76 2 16 4 16 2 16 4416 Maximum sample rate 5 GSa s half channels 2 5 GSa s all channels Maximum memory depth Display size and type Standard 4 Mpts Standard segmented memory 8 5 inch capacitive touch gesture enabled display Waveform update rate Vertical system analog channels Hardware bandwidth limits gt 1 000 000 waveforms per second Approximately 20 MHz selectable Input coup
54. urements and analysis in the oscilloscope Included with the DSOX3PWR is a license for the U1881A PC based power analysis software package which provides additional offline measurements and report generation See www keysight com find DSOX3PWR for more information In addition there are several power specific probes that make analysis of your power supplies e g switch mode power supplies and power consuming devices e g batteries easy 11 00ms 0 0s Auto 1 110m El Power Factor 1 2 659m Real M1 1 34 Apparent 1 2 Reactive 1 Crest 1 Crest 2 Phase Angle 1 AB ay DC RMS Cyel1 2 03V a 100 100k x2 1 0M OM 1 y2 u1y Yi Summary 2 DC 1 001 Math gt M1 Meas Log Ch3 2 0dB 3 75000dB Cursor 1 M1 444adB 3 02187 dB 3 02159d8 7 57362MdB s Application Demo Menu Advanced Features Advanced Power Measurements Serial Advanced t RAR Buses Triggering Math Figure 29a Integrated power measurements make quick work of analyz ing power producing and power consuming devices Analyze Menu Features Analysis Signals Settings Plot View Apel Power Control Loop LL LL Gain PY Figure 29b New control loop response analysis bode plot shows the gain phase plot over frequency sweep t 19 Keysight InfiniiVision 3000T X Series Oscilloscopes Data Sheet Solve Innovative power rail probe option allows enhanced views The power