Home

Flowcon SH User Manual

image

Contents

1. EXTERNALLY ADJUSTABLE DYNAMIC BALANCING VALVE Singapore USA 10 2008 FlowCon International assumes no responsibility for mistakes if any in any printed material FlowCon SH 15 40mm EXTERNALLY ADJUSTABLE DYNAMIC BALANCING VALVE Flow rate setting SH1 and SH2 Flow rate Valve size DN15 DN25 1 2 1 Valve size DN25 DN40 1 1 1 2 33 300 kPaD 4 8 44 psid 33 300 kPaD 4 8 44psid Setting SH 1 1 SH 2 1 l sec I hr GPM l sec War GPM 3 011 396 IZ 0 5 5 0 15 526 2 3 0 6 z 5 0 18 655 2 9 0 7 g 5 0 22 785 3 5 0 8 5 0 25 914 4 0 0 9 0 075 270 12 0 29 1044 4 6 1 0 0 090 324 1 4 0 34 1224 5 4 11 0 105 378 17 0 39 1404 6 2 1 2 0 120 432 1 9 0 44 1584 7 0 1 3 0 135 486 21 0 49 1764 78 tA Use the special designed key 0 15 540 2 4 0 54 1944 8 6 15 FlowCon part no ACC0001 0 17 598 2 6 0 59 2124 9 4 1 6 0 18 655 2 9 0 64 2304 10 1 17 for micrometer setting 0 20 713 3 1 0 69 2484 10 9 1 8 oe ae 34 ari peet u 48 A micrometer setting at 2 4 as 0 25 886 3 9 0 84 3024 13 3 21 illustrated above corresponds 0 26 943 4 2 0 89 3204 14 1 2 2 i 0 28 1001 4 4 0 94 3384 14 9 23 to a flow rate of 0 29 1058 4 7 0 99 3564 15 7 2 4 o ie sr or a roe 0 29 l sec 5 i 2 6 0 34 1217 54 1 10 3960 17 4 2 7 for valve
2. FlowCon SH 15 40mm EXTERNALLY ADJUSTABLE DYNAMIC BALANCING VALVE Assembly drawing FlowCon SH A1 Valve housing B Micrometer setting C Adjustment key Di P t plug 2 pcs D2 Plug and gasket 2 of each E1 Union end connections Figure 2 E E pl 7 d D1 A D1 D2 D2 FroowCon international Denmark Dubai Singapore USA 1A95000 10 2008 4 FlowCon International assumes no responsibility for mistakes if any in any printed material
3. size DN15 20 25 0 35 1267 5 6 1 13 4068 17 9 2 8 0 37 1318 5 8 1 16 4176 18 4 2 9 0 38 1368 6 0 1 19 4284 18 9 3 0 0 99 l sec 0 39 1418 6 2 1 22 4392 19 3 34 i 0 41 1469 6 5 1 25 4500 19 8 3 2 for valve size DN25 32 40 0 42 1519 6 7 1 28 4608 20 3 3 3 0 44 1570 6 9 1 31 4716 20 8 3 4 0 45 1620 71 1 34 4824 21 2 3 5 0 46 1663 73 1 37 4932 21 7 3 6 0 47 1706 75 1 40 5040 22 2 37 0 49 1750 7 7 1 43 5148 22 7 3 8 0 50 1793 7 9 1 46 5256 23 1 3 9 0 51 1836 8 1 1 49 5364 23 6 4 0 0 52 1872 8 2 1 51 5443 24 0 41 0 53 1908 8 4 1 53 5522 24 3 4 2 0 54 1944 8 6 1 56 5602 24 7 4 3 0 55 1980 8 7 1 58 5681 25 0 4 4 0 56 2016 8 9 1 60 5760 25 4 45 0 57 2059 9 1 1 62 5846 25 7 4 6 0 58 2102 9 3 1 65 5933 26 1 4 7 0 60 2146 9 4 1 67 6019 26 5 4 8 0 61 2189 9 6 1 70 6106 26 9 4 9 0 62 2232 98 1 72 6192 27 3 5 0 0 63 2261 10 0 1 74 6271 27 6 5 1 0 64 2290 10 1 1 76 6350 28 0 5 2 0 64 2318 10 2 1 79 6430 28 3 5 3 0 65 2347 10 3 1 81 6509 28 7 54 0 66 2376 10 5 1 83 6588 29 0 55 0 67 2405 10 6 1 85 6674 29 4 5 6 0 68 2434 10 7 1 88 6761 29 8 5 7 0 68 2462 10 8 1 90 6847 30 1 5 8 Accuracy Greatest of either 0 69 2491 11 0 1 93 6934 30 5 5 9 5 of controlled flow rate or 0 70 2520 114 1 95 7020 30 9 6 0 2 of maximum flow rate FrowCon international Denmark Dubai Singapore USA 1A95000 10 2008 E 3 2 FlowCon International assumes no responsibility for mistakes if any in any printed material
4. FlowCon SH 15 40mm EXTERNALLY ADJUSTABLE DYNAMIC BALANCING VALVE INSTALLATION AND OPERATION INSTRUCTION FlowCon SH 15 40mm 1 2 1 1 2 Install the FlowCon SH valve either in the supply or return pipe work for the unit It is recommended that a strainer be installed prior to the valve body to prevent damage or blockage due to debris INSTALL THE VALVE HOUSING WITH THE FLOW DIRECTIONAL ARROW POINTING IN THE CORRECT DIRECTION The valve body is available with double union end connections i e figure 1 Two types of end connections are available for use with the union nut Threaded male or female The thread standard is ISO 228 which is a straight metric thread compatible with BS 2779 or NPT threading standard depending on the end connections ordered The threads on both the connection and piping should be cleaned carefully As these models are union end connected the union nuts and the end connections should be removed for installation O rings are supplied with the valve body and used to seal the connections It is recommended to grease the o rings with a silicone grease before installation IMPORTANT Never use mineral oil or petrol based grease or oil on the o rings Please make sure these are in place in the o ring grooves in the inlet and outlet of the valve body when installing the housing and REMEMBER TO TIGHTEN THE UNION NUTS TO ENSURE SEALING FrowCon international 1A95000 Denmark a ae Du
5. bai For all threaded connections please clear threads on both valve and piping of debris Sealant such as pipe dope or teflon tape is recommended WHEN USING HEMP AS PIPE SEALANT ENSURE NO STRANDS ARE LEFT IN THE VALVE OR PIPING Soldered end sweat REMOVE THE END CONNECTIONS FROM THE HOUSING BEFORE SOLDERING THIS ENSURES THAT THE O RINGS AND INTERNAL PARTS ARE NOT DAMAGED BY HEAT Valve bodies are as standard supplied with body tappings plugged Alternatively the valve body can be ordered with pressure temperature fittings p t plugs for the body tappings Before finger mount ing the p t plugs in the body tappings please seal the threads of the p t plugs DO NOT OVER TIGHTEN Figure 1 USA 10 2008 FlowCon International assumes no responsibility for mistakes if any in any printed material Singapore FlowCon SH 15 40mm General Water must always be suitable treated clean and free of debris It is recommended that a strainer be installed prior to the valve body to prevent damage or blockage due to de bris Ensure that the valve is not in the fully closed position when filling the system with water Further it is recommended not to exceed maximum differential pressure control range Warranty obligation Failure to abide by all recommendations as per this installation and operation instruction will void warranty FroowCon international Denmark Dubai 1A95000 2