1. BAT C 53 Release 01 08 2012 5 8 AT ADRRL Read Roaming List Syntax Description AT ADRRL lt index gt lt CR gt This command reads the BSSID of the selected AP in the roaming list Input and Response Parameters Type Value index integer This is the position in the roaming list bssid Mac_Addr This is the BSSID of the Access Point channel integer This is the channel of the AP Responses Description lt CR gt lt LF gt ADRRL lt index gt lt mac_addr gt The device displays the current parameter lt CR gt lt LF gt OK lt CR gt lt LF gt setting followed by OK after entering a successful read command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 54 BAT C Release 01 08 2012 5 9 AT ADWRL Write Roaming List Syntax AT ADWRL lt index gt lt mac_addr gt lt store_in_startup_database gt lt CR gt Input Parameters Type index integer bssid Mac_Addr channel integer store_in_startup_database integer Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description This command writes the BSSID of the AP in the roaming list Value This is the position in the roaming list This is the BSSID of the Access Point This is the channel of the AP 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configura
2. lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 7 9 AT AMSSC SNMP Sys Contact Syntax Description AT AMSSC lt sys_contact gt Use this command to write the SNMP Sys Contact lt store_in_startup_database gt lt CR gt AT AMSSC lt CR gt Use this command to read the current SNMP Sys Contact Input and Response Parameters Type Value sys_contact String This is a desired string up to 32 characters store_in_startup_ database integer 0 The setting is valid for the current power cycle Responses lt CR gt lt LF gt AMSSC lt sys_contact gt lt CR gt lt LF gt OK lt CR gt lt LF gt BAT C Release 01 08 2012 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command 67 Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description This response indicates a successful execution of the write command This response indicates
3. lt channel gt Input and Response Type Parameters bssid MAC_ Addr op_mode Integer ssid String channel Integer rssi Integer encryption Integer BAT C Release 01 08 2012 Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command Description Use this command to SCAN for available networks The command will return 0 48 networks in the immediate surroundings then return OK Use this command to SCAN the available networks with specific a SSID on a specified channel Value MAC address of the access point 1 Infrastructure 2 Ad hoc SSID name of network Channel the network uses Signal strength value for the network 0 No encryption 1 WEP 2 WPA 3 WPA2 RSN 41 Input and Response Type Parameters information_element String Responses lt CR gt lt LF gt AGSCAN lt bssid gt lt op_mode gt lt ssid gt lt channel gt lt rssi gt lt encryption gt lt information_element gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Value This is a Hexadecimal string with the information element for WPA and RSN networks The string is unavailable for WEP networks or networks without encryption Description The devic
4. In addition we refer to the conditions of use specified in the license contract You can get the latest version of this manual on the Internet at the Hirschmann product site www hirschmann com Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 1805 141538 2 BAT C Release 01 08 2012 Contents ABOUT THIS MANUAL 1 AT COMMAND SYNTAX 1 1 Command Line Format 1 2 Limitations 1 3 Data Types 2 STANDARD AT COMMANDS 2 1 AT Attention Command 2 2 AT List Available Commands 2 3 AT amp F Restore to Factory Settings 2 4 AT amp FO Restore to Factory Settings 2 5 ATE Echo Off 2 6 ATE Echo On Off 2 7 ATQ Result Codes On Off 2 8 ATS2 Escape Character 2 9 ATS3 Command Line Termination Character 2 10 ATS4 Response Formatting Character 2 11 ATS5 Response Formatting Character 2 12 ATS General Settings S Register Manipulation 3 LINK LAYER COMMANDS 3 1 AT AGAM Authentication Mode 3 2 AT AGEM Encryption Mode 3 3 AT AGSM Security Mode 3 4 AT AGOM Operational Mode 3 5 AT AGFP Encryption Authentication Key 3 6 AT AGFPWI Write Encryption Authentication Key with Index 3 7 AT AGAFP Active Encryption Authentication Key 3 8 AT AGUN Username 3 9 AT AGDN Domain name 3 10 AT AGCFP Certificate Fingerprint 3 11 AT AGSSID Network Name SSID 3 12 AT AGRSS RSSI Value 3 13 AT AGCH Channel Number 3 14 AT AGCL Channel List BAT C Release 01 08 2012 NN NON 27 27 28
5. Input and Response Parameters register value Responses lt CR gt lt LF gt value lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Register Roaming registers 1100 BAT C Release 01 08 2012 Description Use this command to write to a general settings S register Use this command to read from a general settings S register Type Description integer Any of the registers described below integer 2147483648 2147483647 or 0x00000000 0xFFFFFFFF Listed below are valid values for each register Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command Description RSSI thresholds Use this by the smart LEDs deciding how to indicate the current RSSI Default value is 0xC9BFB5AB giving the following limits gt 85 dBm gt 1 LED gt 75 dBm gt 2 LEDs gt 65 dBm gt 3 LEDs gt 55 dBm gt 4 LEDs 17 Responses 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 18 Description Reserved Reserved Reserved Reserved Roaming scheme 0 Connect to name see connect to name scheme default 1 Connect to next This wil
6. The device responds with this list of information for the WAN command The device displays the WLAN TX_RATE RSSI and CHANNEL values when connected Furthermore the device displays the BDP_ROLE if the BDP function is turned on followed by an Ok The device returns with this response for integer 4 The device returns with this response for integer 5 The device responds with this list of information for the Ethernet command followed by an Ok The device returns with this response for integer 6 The device returns with this response for integer 7 This response indicates an unsuccessful execution of the write command 81 7 25 AT AMBGID BDP Group Id Syntax Description AT AMBGID lt id gt lt store_in_startup_database gt lt CR gt Use this command to write BDP Group Id AT AMBGID Input and Response Parameters id store_in_startup_database Responses lt CR gt lt LF gt AMBGID lt id gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 82 Use this command to read BDP Group Id Type Value integer 0 BDP is turned off 1 65535 BDP is turned on All devices that are a part in the same seamless roaming redundancy scenario use the same id integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings
7. ADMRP 1 Address to the service on the remote peer In the form of lt protocol gt ipaddr port i e udp 172 23 56 1 5130 Ignored by the BAT C Reserved use 0 This parameter is for future use Use 0 A string with a user defined name of the peer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 5 7 AT ADRL Roaming List Syntax Description AT ADRL Use this command to read the current list of Access Points used for roaming Response Parameters Type Value index integer This is the position in the roaming list bssid Mac_Addr This is the BSSID of the Access Point store_in_startup_ database integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt ADRL lt index gt lt bssid gt The device sends this response for every AP in the list lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command
8. CR gt AT AMSR Use this command to read the current SNMP Receiver status Input and Response Parameters Type Value enable Integer 0 Disables SMNP Receiver 1 Enables SNMP Receiver port Integer This is the UDP port to listen for incoming packets store_in_startup_database Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AMSR lt port gt lt enable gt The device displays the current parameter setting lt CR gt lt LF gt OK lt CR gt lt LF gt followed by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 76 BAT C Release 01 08 2012 7 21 AT AMLCR Link Config Receiver Syntax AT AMLCR lt eth_type gt lt enable gt lt store_in_startup_database gt lt CR gt AT AMLCR Input and Response Type Parameters enable Integer eth_type Integer store_in_startup_database Integer Responses lt CR gt lt LF gt AMLC lt eth_type gt lt enable gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description Use
9. Hoc 0 Auto default 1 11 1 13 or 14 depending on regulatory domain setting for 2 4GHz 36 40 44 48 for 5GHz This parameter is for future use 1 closes the current connection Description lt CR gt lt LF gt ADCPN lt connection_handle gt The device displays the current parameter setting lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command 49 5 4 AT ADCC Close Connection Syntax Description AT ADCC lt connection_handle gt lt CR gt This command Closes an existing network Connection Input Parameters Type Value connection_handle integer 1 closes the current connection Responses Description lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 50 BAT C Release 01 08 2012 5 5 AT ADRDRP Read Default Remote Peer Syntax AT ADRDRP lt peer_id gt lt CR gt Input and Response Type Parameters peer_id Integer address String conn_scheme Integer update_on_incoming Integer name String Responses lt CR gt lt LF gt ADRDRP lt address gt lt conn_scheme gt lt update_on_incoming gt lt name gt lt CR gt l
10. LF gt BAT C Release 01 08 2012 Description Use this command to Log in to the AT command interface Note The User management S register must be set to enable user management Value This is a null terminated string of up to 15 bytes Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 59 7 2 AT AMLO Log Out Syntax AT AMLO lt log_out gt lt CR gt Input Parameters Type log_out Integer Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description Use this command to Log out from the AT command interface Value 1 log out Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 7 3 AT AMGD General Data Syntax AT AMGD lt data gt lt CR gt AT AMGD lt CR gt Input and Response Parameters data Responses lt CR gt lt LF gt lt data gt lt CR gt lt LF gt OK lt CR gt lt LF gt 60 Description Use this command to write data to be stored between power cycles Use this command to read the current previously written data Type Value String Represents the data to store up to 31 bytes long Description The device displays the current parameter setting followed by OK after entering a successful read com
11. LF gt ERROR lt CR gt lt LF gt Value This parameter represents the system services defined by SNMP Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command 7 12 AT AMSBN SNMP Basic Name Syntax AT AMSBN lt basic_name gt lt store_in_startup_database gt lt CR gt AT AMSBN lt CR gt Input and Response Type Parameters basic_name String store_in_startup_database integer BAT C Release 01 08 2012 Description Use this command to write the SNMP Basic Name Use this command to read the current SNMP Basic Name Value This is a desired string up to 32 characters 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration 69 between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AMSBN The device displays the current parameter setting lt basic_name gt lt CR gt lt LF gt OK lt CR gt lt LF gt followed by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 7 13 AT AMSBD SNMP Basic Descriptor Syntax Description AT AMSBD lt basic_d
12. an unsuccessful execution of the write command 7 10 AT AMSSL SNMP Sys Location Syntax AT AMSSL lt sys_location gt lt store_in_startup_database gt lt CR gt AT AMSSL lt CR gt Input and Response Parameters sys_Location store_in_startup_ database Responses lt CR gt lt LF gt AMSSL Type String integer lt sys_location gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 68 Description Use this command to write the SNMP Sys Location Use this command to read the current SNMP Sys Location Value This is a desired string up to 32 characters 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 7 11 AT AMSSS SNMP Sys Services Syntax Description AT AMSSS lt CR gt Use this command to read the current SNMP Sys Services Response Type Parameters sys_services Integer Responses lt CR gt lt LF gt AMSSS lt sys_services gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt
13. be used There is no distinction between upper and lower case characters The body is a string of characters in the range ASCII 032 255 Control characters other than lt CR gt carriage return ASCII 13 and lt BS gt backspace ASCII 8 in a command line are ignored The terminator is lt CR gt Commands denoted with a character are extended AT commands i e BAT C specific AT commands The command line is limited to one command at a time Terminate each command with a lt CR gt before sending a new command The limit of acommand line is 300 characters A command can either be gt Read commands without parameters AT lt command gt lt CR gt gt Write commands without parameters AT lt command gt lt CR gt gt Read and write commands with parameters AT lt command gt lt parameter1 gt lt parameter2 gt lt parameterN gt lt CR gt The device sends responses back to the host and can be any of the following gt This response indicates a successful execution of the write command lt CR gt lt LF gt OK lt CR gt lt LF gt gt A read command will precede the OK response with the read parameters The form is lt CR gt lt LF gt lt command gt lt param1 gt lt param2 gt lt paramN gt lt CR gt lt LF gt String results will have around them gt Successful intermediate final message with parameters follows an OK message in some commands In these cases the OK message works as a confirmation message only
14. database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 7 26 AT AMWID Wireless interface disable Syntax Description AT AMWID lt disable gt lt store_in_startup_database gt lt CR gt Use this command to Disable the AT AMWID Input and Response Parameters disable store_in_startup_database Responses lt CR gt lt LF gt AMWID lt disable gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Wireless Interface Use this command to read the Wireless Interface Disabled status Type Value integer 0 Wireless interface enabled 1 Wireless interface is disabled integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 83 7 27 AT AMPSM Profisafe Mode Synt
15. gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt HW_ADDR lt wlan_mac_addr gt lt CR gt lt LF gt STATUS lt wlan_status gt lt CR gt lt LF gt OP_MODE lt op_mode gt lt CR gt lt LF gt SSID lt ssid gt lt CR gt lt LF gt BSSID lt bssid gt lt CR gt lt LF gt TX_RATE lt data_rate gt lt CR gt lt LF gt RSSlI lt rssi gt lt CR gt lt LF gt CHANNEL lt channel gt lt CR gt lt LF gt BDP_ROLE lt role gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt HW_ADDR lt eth_mac_addr gt lt CR gt lt LF gt STATUS lt eth_status gt lt CR gt lt LF gt IP_ADDR lt ip_addr gt lt CR gt lt LF gt SUBNET_MASK lt subnet gt lt CR gt lt LF gt GATEWAY lt gateway gt lt CR gt lt LF gt DHCP lt dhcp_mode gt lt CR gt lt LF gt DNS1 lt dns1 gt lt CR gt lt LF gt DNS2 lt dns2 gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Value This is the Primary DNS server This is the Secondary DNS server Description The device returns with this response for integer 1 The device responds with this information for the common command followed by an OK The device returns with this response for integer 2 The device returns with this response for integer 3
16. happens 1 32 default 30 Averaging depth for the lost beacon trigger 1 32 default 32 Reserved Reserved Beacon Period of the BSS Descriptor of the ESS to Join or Start a network in IBSS Value in milliseconds 100 default 100 Use this register to configure the time limit in units of beacon intervals after which termination of the Join procedure occurs 1 100 default 10 Reserved Max power use AT AMMP Reserved Data Rate use AT AGRTE BAT C Release 01 08 2012 Responses 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 BAT C Release 01 08 2012 Description Link Adaption use AT AGRTE 0 Disable 1 Enable Power save 0 Disable 1 Enable Regulatory domain 1 World Domain default 1 11 2 4GHz 2 FCC 1 11 2 4GHz 3 ETSI 1 13 2 4GHz 4 TELEC 1 14 2 4GHz 10 U NII 1 86 40 44 48 5GHz 20 U NII 2 52 56 60 64 5 GHz 40 U NII 2 extended 100 104 108 116 120 124 128 132 136 140 5 GHz The regulatory domain values can be added if multiple options are required For example 21 20 1 represents option 1 and option 20 and signifies World Domain and U NII 1 Note After changing the regulatory domain verify that the channel list is updated according to your preferences as well AT AGCL DTIM Enable 0 Disable 1 Enable default QoS Enable 0 Disable 1 Enable default Reserved Reserved Reserved Res
17. lt CR gt lt LF gt lt result_response gt lt parameter1 gt parameter2 gt lt parameterN gt This response indicates an unsuccessful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt 1 2 Limitations When a AT command is issued with the store parameter set to 1 the previous values will be stored as well regardless of whether the previous commands where issued with the store parameter set to 1 or not 1 3 Data Types The definition of each command specifies the data types used for values associated with the command There are four different data types String Octet String Integer IP_Addr MAC_Addr vVvvVvvVY BAT C 7 Release 01 08 2012 The follow paragraph describes the Data Type listed above gt String A string consists of a sequence of displayable characters from the ISO 8859 1 8 bit ASCII character set except for characters and characters below 32 space A string constant shall be delimited by two double quote characters e g Donald Duck Use the character as an escape character to insert raw bytes in a string If the double quote character is to be used within a string e g My friend Bono is a singer they have to be represented as 22 If the back slash character is to be used within a string constant it has to be represented as 5C An empty string is represented by two adjacent delimiters Octet String An octet string shall
18. lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description Use this command to write Security Mode Security Mode is a shortcut for setting a combination of the authentication and encryption modes Sending a AT AGSM 3 command is therefore the equivalent of sending the commands AT AGAM 2 and AT AGEM 3 If you send a AT AGSM command the DCE will return 255 if the current settings do not match the predefined values Use this command to read the current security mode Type Value Integer 0 No security default AM 0 EM 0 1 Shared WEP64 AM 1 EM 1 2 Shared WEP128 AM 1 EM 2 3 WPA PSK TKIP AM 2 EM 3 4 WPA2 PSK AES CCMP AM 2 EM 4 5 LEAP WPA2 AM 3 EM 4 6 LEAP WEP128 AM 3 EM 2 Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 29 3 4 AT AGOM Operational Mode Syntax AT AGOM lt omode gt lt store_in_startup_database gt lt CR gt AT AGOM Input and Response Parameters omode store_in_startup_database Responses lt CR gt lt LF gt AGOM lt omode gt lt CR gt lt LF gt OK
19. servers See AT AGAM Authentication Mode Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 3 9 AT AGDN Domain name Syntax Description AT AGDN lt domain gt Use this command to write the Domain Name lt store_in_startup_database gt lt CR gt AT AGDN Use this command to read the current the Domain Name Input and Response Parameters Type Value domain String This is the domain to use with authentication servers See AT AGAM Authentication Mode store_in_startup_database Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AGDN lt domain gt The device displays the current parameter setting followed by lt CR gt lt LF gt OK lt CR gt lt LF gt OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt l
20. the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 7 19 AT AMHL HTTP Listener Syntax AT AMHL lt port gt lt enable gt lt store_in_startup_database gt lt CR gt AT AMHL Input and Response Type Parameters enable Integer port Integer store_in_startup_database Integer Responses lt CR gt lt LF gt AMHL lt port gt lt enable gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description Use this command to enable or disable the HTTP Listener Use this command to read the current HTTP Listener status Value 0 Disables HTTP Listener 1 Enables HTTP Listener TCP port to listen for incoming connections 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 75 7 20 AT AMSR SNMP Receiver Syntax Description AT AMSR lt port gt lt enable gt Use this command to enable or disable the SNMP Receiver lt store_in_startup_database gt lt
21. the ordinal value 30 in place of the CR ATS3 Use this command to read the current command line termination character Input and Response Parameters Type Description line_term integer 0 127 13 CR is default Responses Description lt CR gt lt LF gt line_term lt CR gt lt LF gt OK lt CR gt lt LF gt The device displays the current parameter setting followed by OK after entering a successful read command lt line_term gt lt LF gt OK lt line_term gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the 14 write command BAT C Release 01 08 2012 2 10 ATS4 Response Formatting Character Syntax Description ATS4 lt term gt lt CR gt Use this command to write response formatting character This setting changes the decimal value of the character generated by the DCE as part of the header trailer and terminator for result codes and information text along with the S3 parameter If you change the value of S4 in a command line the result code issued in response to that command line will use the new value of S4 ATS4 Use this command to read the current response formatting character Input and Response Parameters Type Description term integer 0 127 10 LF is default Responses Description lt CR gt lt LF gt term The device displays the current parameter setting followe
22. 29 30 31 32 33 34 35 36 37 38 39 40 3 15 3 16 AT AGSCAN AT AGRTE Data Rate and Link Adaptation 4 NETWORK LAYER COMMANDS 4 1 4 2 4 3 4 4 AT ANIP IP Settings AT ANDHCP DCHP Activation AT ANHN Hostname AT ANDNS DNS Settings 5 DATA MODE COMMANDS 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5 10 AT ADC Connect AT ADCGP Connect to BSSID AT ADCPN Connect to name SSID AT ADCC Close Connection AT ADRDRP Read Default Remote Peer AT ADWDRP Write Remote Peer Information AT ADRL Roaming List AT ADRRL Read Roaming List AT ADWRL Write Roaming List AT ADLNK Read WLAN link status 6 INFORMATIONAL COMMANDS 6 1 6 2 AT AILBA Read Local MAC Address AT AILVI Local version 7 MISCELLANEOUS COMMANDS 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 9 7 10 7 11 7 12 7 13 AT AMLI Log in AT AMLO Log Out AT AMGD General Data AT AMMP Max Output Power AT AMWS Watchdog Settings AT AMESS Event and Status Subscriber AT AMSMF SMART Mode Button functionality AT AMSMFL SMART Mode Function List AT AMSSC SNMP Sys Contact AT AMSSL SNMP Sys Location AT AMSSS SNMP Sys Services AT AMSBN SNMP Basic Name AT AMSBD SNMP Basic Descriptor 41 42 44 44 45 46 47 48 48 48 49 50 51 52 53 54 55 56 57 57 58 59 59 60 60 61 62 63 64 66 67 68 69 69 70 BAT C Release 01 08 2012 7 14 7 15 7 16 7 17 7 18 7 19 7 20 7 21 7 22 7 23 7 24 7 25 7 26 7 27 AT AMSSD SNMP Sys Description A
23. 901 1902 1903 1904 WLAN 3000 3001 BAT C Release 01 08 2012 Description Write diagnose mode bitmask Default value is 0x00000001 This function sends the following events when the bit is set Bit 0 ADCPO Connection up ADCCO Connection down AMDST Digital signal transition AMRSS RSSI value below 70dBm Bit 1 AGRSS RSSI periodically sent with interval set by ATS register 1219 AGCH Used WLAN channel sent upon connection setup Bit 2 AGSCAN Background scan result RSSI poll interval in milliseconds Default value is 1000 ms Maximum time to wait for first push on SMART button Default value is 5000 ms Reserved Reserved Profinet prioritization 0 Disable default 1 Enable Reserved Ethernet type to prioritize default 0x8892 WLAN preamble 0 Long preamble 1 Short preamble default Reserved 21 Responses 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 22 Description WLAN minimum scan time in milliseconds on each channel 0 65535 default 50 WLAN maximum scan time in milliseconds on each channel 0 65535 default 200 WLAN scan type 0 Active scan default 1 Passive scan Reserved Averaging depth for the RSSI trigger 1 16 default 4 1 means no depth WLAN lower lost beacon value to trigger a rescan The maximum number of lost beacons before a rescan
24. C Release 01 08 2012 Description Use this command to read the current status of a specific interface Value 1 Common 2 Reserved 3 WLAN 4 Reserved 5 Ethernet 6 Reserved 7 Reserved 79 Input and Response Parameters id uptime wlan_mac_addr wlan_ status op_mode ssid bssid data_rate rssi channel role eth_mac_addr eth_status ip_addr subnet gateway dhcp_mode 80 Type integer integer MAC_Addr integer integer string MAC_Addr integer integer integer integer MAC_Addr integer IP_Addr IP_Addr IP_Addr integer Value 0 This entry is optional This is the uptime in seconds This is the WLAN MAC address 0 Not associated 1 Associated 1 Managed 2 Ad hoc This is the SSID of the AP This is the BSSID of the AP or associated device See AT AGRTE for further details See AT AGRSS for further details This is the Channel Lists the BDP role 1 Available 2 Master 3 Slave This is the Ethernet MAC address Lists the Ethernet Link Status 0 Link is down 1 Link is up This is the Static IP address or assigned IP address when using DHCP This is the Subnet mask This is the Gateway IP address This is the DHCP mode see AT ANDHCP for further details BAT C Release 01 08 2012 Input and Response Type Parameters dns1 IP_ Addr dns2 IP_ Addr Responses UPTIME lt uptime
25. Entering 0 will disable the feature Reserved Reserved Disable Link configuration if broadcast Reserved Reserved Reserved Event Subscriber Protocol The device sends events according to this value 0 disable default 1 Messages sent by AT over TCP 2 Messages sent by AT over Layer 2 mac_address must be specified using AT AMESS 3 Syslog destination IP address must be specified using AT AMESS 4 255 reserved Event Subscriber Port Ethernet type 19 Responses 1209 1210 1211 1212 1213 1214 1215 1216 1217 20 Description Wireless Interface Disable 0 Enable Wireless Interface default 1 Disable Bridge Cache Timeout Time in seconds before MAC address cache table in the bridge throws away an entry Bit mask representing SMART LED Mode when finishing smart mode Bit 0 RSSI Bit 1 RESERVED Bit 2 BDP role Bit 3 31 RESERVED Smart LED Update timeout in seconds Activate User Management 0 disable 1 enable Smart mode button push functionality 0 Disconnect connect 1 Toggle ALL LEDs 2 Reset Smart mode button hold functionality 0 Disconnect connect 1 Toggle ALL LEDs 2 Reset External trigger push functionality 0 Disconnect connect 1 Toggle ALL LEDs 2 Reset External trigger hold functionality 0 Disconnect connect 1 Toggle ALL LEDs 2 Reset BAT C Release 01 08 2012 Responses 1218 1219 1220 Profinet 1900 1
26. HIRSCHMANN A BELDEN BRAND CLI Reference Industrial Wireless LAN Client BAT C BAT C Technical Support Release 01 08 2012 https hirschmann support belden eu com The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and trade name protection law and hence that they may be freely used by anyone 2012 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use For devices with embedded software the end user license agreement on the enclosed CD applies The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no responsibility for damages resulting from the use of the network components or the associated operating software
27. NIP lt ip_addr gt The device displays the current parameter setting followed by OK lt netmask gt lt gw gt after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 44 BAT C Release 01 08 2012 4 2 AT ANDHCP DCHP Activation Syntax Description AT ANDHCP lt dhcp_mode gt Activate deactivate DHCP lt store_in_startup_database gt lt CR gt If activated this configuration will take precedence over the settings made with AT ANIP AT ANDHCP Use this command to read the current DHCP setting Input and Response Type Value Parameters dhcp_mode integer 0 Static enter a static IP address default 1 DHCP Client acquire an IP address using DHCP 2 DHCP Server use a static IP address and act as DHCP server 3 Auto IP The BAT C will be assigned a private IP address with a prefix of 169 254 16 4 DHCP Relay use a static IP address and act as DHCP relay 5 DHCP Client DHCP Relay acquire an IP address using DHCP then act as DHCP relay default store_in_startup_database integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Respo
28. T AMSWC SNMP Write Community Private Community AT AMSEID SNMP Enterprise ID AT AMTL TCP Listener AT AMUR UDP Receiver AT AMHL HTTP Listener AT AMSR SNMP Receiver AT AMLCR Link Config Receiver AT ACEW Configure Mode AT AMEO Set External Digital Output AT AMSTAT Read Current Status AT AMBGID BDP Group Id AT AMWID Wireless interface disable AT AMPSM Profisafe Mode 8 EVENTS 8 1 8 2 8 3 8 4 ADCPO Connection Up ADCCO Connection Closed AMDST Digital Signal Transition AMRSS Low RSSI Warning A FURTHER SUPPORT BAT C Release 01 08 2012 71 72 72 73 74 75 76 77 78 79 79 82 83 84 85 85 85 86 86 87 About this manual The following manuals are available as PDF files on the CD ROM supplied User Manual Configuration and Administration gt Reference Manual gt User Manual Installation Related Documents BAT C User Manual Configuration and Administration This is a quick setup guide to be able to setup the BAT C for the simplest out of the box applications BAT C User Manual Installation This is a detailed specification or reference for all of the supported AT commands 6 BAT C Release 01 08 2012 1 AT command syntax 1 1 Command Line Format Each command line sent from the DTE data terminal equipment to the DCE data communications equipment consists of a prefix body and terminator As prefix for the BAT C AT commands only AT ASCII 65 84 and at ASCII 97 116 can
29. The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter lt short_mode gt lt long_mode gt lt CR gt lt LF gt OK lt CR gt lt LF gt setting followed by OK after entering a lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 65 7 8 AT AMSMFL SMART Mode Function List Syntax AT AMSMFL lt smart_mode_1 gt lt smart_mode_2 gt lt smart_mode_3 gt lt smart_mode_4 gt lt smart_mode_5 gt lt smart_mode_6 gt lt smart_mode_7 gt lt smart_mode_8 gt lt smart_mode_9 gt lt smart_mode_10 gt lt smart_mode_11 gt lt smart_mode_12 gt lt smart_mode_13 gt lt smart_mode_14 gt lt smart_mode_15 gt lt store_in_startup_database gt lt CR gt AT AMSMFL lt CR gt Input and Response Type Parameters smart_mode_ Integer store_in_startup_database integer 66 Description Use this command to write the sequence of SMART button functionality modes Example AT AMSMFL 15 2 3 4 5 11 12 0 0 0 0 0 0 0 0 1 will limit the number of SMART modes to 7 The first mode indicated by the A LED will be 15 see list below the second indicated by the B LED will be 2 and
30. alid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 73 7 18 AT AMUR UDP Receiver Syntax AT AMUR lt port gt lt enable gt lt store_in_startup_database gt lt CR gt AT AMUR Input and Response Type Parameters enable Integer port Integer store_in_startup_database Integer Responses lt CR gt lt LF gt AMUR lt port gt lt enable gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 74 Description Use this command to enable or disable the UDP Receiver Use this command to read the current UDP receiver activation status Value 0 Disables UDP Receiver 1 Enables UDP Receiver UDP port to listen for incoming packets 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of
31. ann Competence Center you have decided against making any compromises Our client customized package leaves you free to choose the service components you want to use Internet http www hicomcenter com BAT C 87 Release 01 08 2012
32. ax AT AMPSM lt ps_mode gt lt store_in_startup_database gt lt apply_without_restart gt lt CR gt AT AMPSM Input and Response Parameters ps_mode store_in_startup_database apply_without_restart Responses lt CR gt lt LF gt AMPSM lt ps_mode gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 84 Description Use this command to enable ProfiSafe Mode This command disables the write configuration mode However with the ProfiSafe Mode enabled you are able to read the configuration on the device To amend the configuration set the device in configuration mode with AT ACEW or reset to factory defaults with AT amp FO Use this command to read the ProfiSafe Mode Status Type Value integer 0 ProfiSafe Mode disabled 1 ProfiSafe Mode enabled integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database integer This entry is optional 1 The device enters the ProfiSafe Mode directly without a restart when setting this entry to 1 This command disables the write configuration mode immediately after execution Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write comman
33. consist of an even number of hexadecimal values Valid values are 0 9 a f and A F Integer An integer value consists of a sequence of characters all in the range 0 9 An integer can also be represented by as hexadecimal string e g 15 can be written as OxO000000F excluding the double quote characters IP_Addr A valid IP address consists of four integer values separated by dots Valid range of each integer value is 0 255 An example IP address is 192 168 0 1 excluding the double quote characters MAC_ Addr A MAC consists of a sequence of six values expressed in two digit hexadecimal in sequence Group the hexadecimal values together without delimiters An example MAC address is OOAOF7101C08 excluding the double quote characters The MAC address is an Octet String with a fixed length of 12 BAT C Release 01 08 2012 2 Standard AT Commands 2 1 AT Attention Command Syntax AT lt CR gt Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description This is an ATtention command determining the presence of a DCE i e the Ethernet Port Adapter Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 2 2 AT List Available Commands Syntax Description AT lt CR gt Lists the supported AT commands Responses Description lt CR gt lt LF gt l
34. d This response indicates an unsuccessful execution of the write command 57 6 2 AT AILVI Local version Syntax AT AILVI lt CR gt Response Parameters manufacturer spa_Sw_version wlan_driver_version wlan_fw_version wlan_hw_manufacturer Responses lt CR gt lt LF gt AILVI lt manufacturer gt lt spa_Sw_version gt lt wlan_driver_version gt lt wlan_fw_version gt lt wlan_hw_manufacturer gt Description This command reads the local version information to the Ethernet Port Adapter Type Value String This is the Ethernet port adapter manufacturer i e Hirschmann String This is the Ethernet port adapter software version i e 2 3 2 11 32 15 May 14 2012 String This is the WLAN host driver version i e 2 12 1 String This is the WLAN firmware version i e 3 2 8 5 String This is the WLAN hardware manufacturer example RPS Description The device displays the current parameter setting followed by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 58 BAT C Release 01 08 2012 7 Miscellaneous Commands 7 1 AT AMLI Log in Syntax AT AMLI lt password gt lt CR gt Input Parameters Type password String Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt
35. d This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 8 Events 8 1 ADCPO Connection Up Event Description ADCPO lt connection_handle gt After establishing a connection to a remote device the BAT C lt network_type gt transmits the event lt mac_addr gt lt bssid gt lt CR gt lt LF gt Input and Response Type Value Parameters connection_handle integer Identifies the connection network_type integer 1 Managed 2 Ad Hoc mac_addr Mac_Addr Local mac address bssid Mac_Addr Bssid of the network we are connected to 8 2 ADCCO Connection Closed Event Description ADCCO lt connection_handle gt After disconnecting from a remote device the BAT C transmits lt reason gt the event lt mac_addr gt lt bssid gt lt CR gt lt LF gt Input and Response Type Value Parameters connection_handle integer Identifies the connection BAT C 85 Release 01 08 2012 Input and Response Type Parameters reason integer mac_addr Mac_Addr bssid Mac_Addr 8 3 AMDST Digital Signal Transition Event AMDST lt mac_addr gt lt CR gt lt LF gt Parameters Type mac_addr Mac_Addr 8 4 AMRSS Low RSSI Warning Event AMRSS lt mac_addr gt lt rssi gt lt CR gt lt LF gt Response Parameters Type mac_addr Mac_Addr rssi Integer Licenses 86 Value 0 Disconnected by command 1 Disconnected by link loss 255 Reason unknown Local MAC address Bssid of the network we w
36. d by lt CR gt lt LF gt OK lt CR gt lt LF gt OK after entering a successful read command lt CR gt lt LF OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command BAT C 15 Release 01 08 2012 2 11 ATS5 Response Formatting Character Syntax ATS5 lt backspace gt lt CR gt ATS5 Input and Response Parameters backspace Responses lt CR gt lt LF gt backspace lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 16 Description Use this command to write backspace character This setting changes the decimal value of the character recognized by the DCE as a request to delete from the command line the immediately preceding character Use this command to read the current backspace character Type Description integer 0 127 8 BS is default Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 2 12 ATS General Settings S Register Manipulation Syntax ATS lt register gt lt value gt lt CR gt ATS lt register gt
37. e displays the current parameter setting followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command 3 16 AT AGRTE Data Rate and Link Adaptation Syntax AT AGRTE lt data_rate gt lt link_adaptation gt lt store_in_startup_database gt lt CR gt AT AGRTE 42 Description Use this command to write the data Rate and link adaptation settings Use this command to read the current data Rate and link adaptation settings BAT C Release 01 08 2012 Input and Response Type Parameters data_rate Integer link_adaptation Integer store_in_startup_database Integer Responses lt CR gt lt LF gt AGRTE lt data_rate gt lt link_adaption gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Value 1 1Mbit only 2 4GHz 2 2Mbit only 2 4GHz 3 5 5Mbit only 2 4GHz 4 6Mbit 5 9Mbit 6 11Mbit only 2 4GHz 7 12Mbit 8 18Mbit 9 24Mbit default 10 36Mbit 11 48Mbit 12 54Mbit 13 6 5Mbit 14 13Mbit 15 19 5Mbit 16 26Mbit 17 39Mbit 18 52Mbit 19 58 5Mbit 0 Link adaptation off The device uses the configured data_rate 1 Link adaptation on The data_rate of the device adjusts automatically depending on the operation environment 0 The setting is valid for the current
38. ect_timeout gt lt disconnect_reset gt lt reset gt lt store_in_startup_database gt lt CR gt AT AMWS Input and Response Parameters reserved1 inactivity_timeout connect_timeout disconnect_reset reset store_in_startup_database 62 Type Integer Integer Integer Integer Integer Integer Description Use this command to write the watchdog settings The watchdog functionality will disconnect from a remote peer for one of the given conditions Use this command to read the current watchdog settings Value This parameter is for future use This is a O for this parameter This is the time in seconds before the BAT C resets if it receives no data on the WLAN interface 0 Disabled default value gt 0 Timeout in seconds This is the Max connection time in seconds before the BAT C resets 0 Disabled default value gt 0 Timeout in seconds 0 Disabled default value 1 Enabled the BAT C will reset on a terminated connection 1 Reset the unit immediately Will not store nor return any response 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database BAT C Release 01 08 2012 Responses Description lt CR gt lt LF gt AMWS lt reserved gt The device displays the current parameter setting followed by lt inactivity_timeout gt OK after enterin
39. er TCP 2 Messages sent by AT over Layer 2 mac_address must be specified FFFFFFFFFFFF means that it will be broadcasted 3 Syslog 4 255 reserved 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 7 7 AT AMSMF SMART Mode Button functionality Syntax AT AMSMF lt short_mode gt lt long_mode gt lt store_in_startup_database gt lt CR gt AT AMSMF lt CR gt 64 Description Use this command to write the SMART button functionality Use this command to read the current SMART button functionality BAT C Release 01 08 2012 Input and Response Parameters short_mode long_mode store_in_startup_database Responses lt CR gt lt LF gt AMSMF Type Integer Integer integer Value Manage the Push functionality with the following values 0 Trigger roaming disconnect connect 1 Toggle Leds 2 Soft reset Manage the Hold functionality with the following values 0 Trigger roaming disconnect connect 1 Toggle Leds 2 Soft reset 0 The setting is valid for the current power cycle 1
40. ere previously connected to Description The device transmits theis event after detecting an external Digital Signal Transition Value MAC address of the device Description The RSSI value is below 70 dBm Value MAC address of the device RSSI value BAT C Release 01 08 2012 A Further Support Technical Questions For technical questions please contact any Hirschmann dealer in your area or Hirschmann directly You will find the addresses of our partners on the Internet at http www hirschmann com Contact our support at https hirschmann support belden eu com You can contact us in the EMEA region at gt Tel 49 0 1805 14 1538 gt E mail hac support belden com in the America region at gt Tel 1 717 217 2270 gt E mail inet support belden com in the Asia Pacific region at gt Tel 65 68549860 gt E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors gt Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification gt The current training courses to technology and products can be found at http www hicomcenter com gt Support ranges from the first installation through the standby service to maintenance concepts y With the Hirschm
41. erved Reserved 23 Responses 3027 3028 3029 4000 4001 4002 4003 4004 4005 4006 24 Description Background scanning idle timeout default 1000 ms When there has been no data activity for the last idle timeout ms the background scan starts idie timer 1 sec Always timer 4 sec Background scanning interval Time between background scans default 5000 ms Background scanning scheme Configure when to initiate background scanning with this register A prerequisite for this is that the RSSI level is below Trigger Scan RSSI ATS4012 0 Always in intervals of ATS3028 ms 1 When idle the idle time is checked every ATS3028 ms Reserved do not modify Reserved do not modify Reserved do not modify WPA key input mode Controls how the WPA key is parsed and interpreted 0 Auto default 1 ASCII 2 Hexadecimal Auto mode will try to determine if it the input is an ASCII key or a HEX key by looking at the contents Reserved Reserved Reserved BAT C Release 01 08 2012 Responses 4007 4008 4009 4010 4011 4012 4013 4014 Networking BAT C Release 01 08 2012 Description Reserved do not modify Ad hoc timeout Time before a single unit in an ad hoc network tries a rescan to find an existing network Value in milliseconds 0 disabled 0 2147483647 default 6000 Delayed association This value sets the time to wait before init
42. escription Configuring this parameter determines whether or not the unit transmits result codes to the DTE Quit When suppressing result codes no transmission of any portion of any intermediate final or unsolicited result code i e header result text line terminator or trailer occurs The value of this parameter has no affects on information text transmitted in response to commands Use this command to read the current result code setting Quit Type Description integer 0 Unit transmits result codes 1 Result codes are suppressed BAT C Release 01 08 2012 Responses lt CR gt lt LF gt result_off lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 2 8 ATS2 Escape Character Syntax ATS2 lt esc_char gt lt CR gt ATS2 Input and Response Parameters esc_char Responses lt CR gt gt LF gt esc_char lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description This command is issued to change the escape character to esc_cha
43. escriptor gt Use this command to write the SNMP Basic Descriptor lt store_in_startup_database gt lt CR gt AT AMSBD lt CR gt Use this command to read the current SNMP Basic Descriptor Input and Response Parameters Type Value basic_descriptor String This is a desired string up to 32 characters store_in_startup_database integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AMSBD The device displays the current parameter setting followed by lt basic_descriptor gt lt CR gt lt LF gt OK lt OK after entering a successful read command CR gt lt LF gt 70 BAT C Release 01 08 2012 Responses Description lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 7 14 AT AMSSD SNMP Sys Description Syntax Description AT AMSSD lt basic_description gt Use this command to write the SNMP System Description lt store_in_startup_database gt lt CR gt AT AMSSD lt CR gt Use this command to read the current SNMP System Description Input and Response Parameters Type Value basic_description String This is a desired string up to 32 characters store_in_startup_database integer 0 The sett
44. g a successful read command lt connect_timeout gt lt disconnect_reset gt lt reset gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 7 6 AT AMESS Event and Status Subscriber Syntax Description AT AMESS lt mac_addr gt Use this command to write the Event and Status subscriber lt ip_addr gt lt port gt lt protocol gt lt store_in_startup_database gt lt CR gt AT AMESS lt CR gt Use this command to read the current Event and Status subscriber Input and Response Type Value Parameters mac_addr MAC_Addr This is the MAC address of event subscriber ip_addr IP_Addr This is the IP address of event subscriber port Integer This is the port number of event subscriber 0 use default Layer 2 events must be specified BAT C 63 Release 01 08 2012 Input and Response Type Parameters protocol Integer store_in_startup_database integer Responses lt CR gt lt LF gt AMESS lt mac_addr gt lt ip_addr gt lt port gt lt protocol gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Value Manage event transmission using the following values 0 disable default 1 Messages sent by AT ov
45. he time in milliseconds for a TCP connection to be idle before sending a keep alive packet 0 2147483647 default 7200000 2 hours This is the time in milliseconds between keep alive packets after losing a keep alive packet 0 2147483647 default 75000 75 seconds This is the number of lost keep alive packets to wait before resetting a TCP connection 1 255 default 9 BAT C Release 01 08 2012 3 Link Layer Commands 3 1 AT AGAM Authentication Mode Syntax Description AT AGAM lt amode gt Use this command to write Authentication Mode lt store_in_startup_database gt lt CR gt AT AGAM Use this command to read the current Authentication Mode Input and Response Parameters Type Value amode Integer 0 Open default 1 Shared secret 2 WPA WPA2 PSK 3 LEAP 4 PEAP 5 Reserved store_in_startup_database Integer 0 The setting will be valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AGAM lt amode gt The device displays the current parameter setting followed by lt CR gt lt LF gt OK lt CR gt lt LF gt OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the wr
46. his command to connect to a previously configured WLAN network Responses Description lt CR gt lt LF gt ADC lt connection_handle gt The device displays the current parameter setting lt CR gt lt LF gt OK lt CR gt lt LF gt followed by OK after entering a successful read command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 5 2 AT ADCP Connect to BSSID Syntax Description AT ADCP lt BSSID gt Use this command to connect to a WLAN network Managed mode lt network_type gt lt wlan_channel gt lt ssid gt lt CR gt Input Parameters Type Value BSSID Mac_Addr This is the BSSID of the desired AP network_type Integer 1 Managed mode wlan_channel Integer 0 Auto default 1 11 1 13 or 14 depending on regulatory domain setting for 2 4GHz 36 40 44 48 for 5GHz ssid String This is the SSID of the desired AP 48 BAT C Release 01 08 2012 5 3 AT ADCPN Connect to name SSID Syntax AT ADCPN lt SSID gt lt network_type gt lt wlan_channel gt lt reserved gt lt CR gt Input and Response Parameters SSID network_type wlan_channel Reserved connection_handle Responses Description Use this command to connect to a WLAN network specified by the SSID Type string Integer Integer Integer Integer Value This is the SSID of the desired AP or Ad Hoc unit 1 Managed mode 2 Ad
47. his response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 4 4 AT ANDNS DNS Settings Syntax Description AT ANDNS lt dns1 gt lt dns2 gt lt store_in_startup_database gt lt CR gt Use this command to write the name server DNS information AT ANDNS Use this command to read the current name server DNS information Input and Response Type Value Parameters dns1 IP_Addr This is the Primary DNS server If DNS is not used set this parameter to 0 0 0 0 default 0 0 0 0 dns2 IP_Addr This is the Secondary DNS server If DNS is not used or if one server is used set this parameter to 0 0 0 0 default 0 0 0 0 store_in_startup_database integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt ANDNS lt dns1 gt lt dns2 gt The device displays the current parameter setting followed lt CR gt lt LF gt OK lt CR gt lt LF gt by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 47 5 Data Mode Commands 5 1 AT ADC Connect Syntax Description AT ADC lt CR gt Use t
48. iating an association attempt Value in milliseconds 0 no delay 0 2147483647 default 0 LLDP send interval The module sends per default information in LLDP frames with its current setup and those of its peers Another use for this parameter is to stay alive on access points that do not properly wake the module before a disassociation Value in seconds 0 Do not send 0 2147483 default 60 Reserved Trigger Scan RSSI Defines at what RSSI level to initiate a background scan to search for a better connection Normally when using BDP the Slave exclusively performs background scanning in intervals However when the Slave is lost the Master assumes this task The Master searches for a better connection when RSSI exceeds this value LLDP hold multiplier This value multiplied with LLDP interval equals the total time an LLDP update is valid 1 10 default 4 Enable disable adaptive RSSI threshold 0 Disable default 1 Enable 25 Responses 5000 5001 5002 5003 26 Description Turn on off TCP keep alive packets It is important to understand that sending frequent keep alive packets usually isn t a good solution to detect dropped connections Perform dead links detection on a higher level i e in the user application protocol There is a lot of information available on the subject on the web 0 TCP keep alive packets turned off default 1 TCP keep alive packets turned on This is t
49. ing is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AMSBD The device displays the current parameter setting lt basic_description gt lt CR gt lt LF gt OK lt CR gt lt LF gt followed by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command BAT C 71 Release 01 08 2012 7 15 AT AMSWC SNMP Write Community Private Community Syntax Description AT AMSWC lt community gt Use this command to write the SNMP Private lt store_in_startup_database gt lt CR gt Community name The BAT C currently supports 1 Input Parameters community store_in_startup_database Responses lt CR gt lt LF gt OK lt CR gt lt LF gt community that has both read and write access Type Value String This is a desired string up to 12 characters integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an un
50. ite command BAT C 27 Release 01 08 2012 3 2 AT AGEM Encryption Mode Syntax Description AT AGEM lt emode gt lt store_in_startup_database gt lt CR gt Use this command to write Encryption AT AGEM Input and Response Parameters emode store_in_startup_database Responses lt CR gt lt LF gt AGEM lt emode gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 28 Mode Use this command to read the current Encryption Mode Type Value Integer 0 None default 1 WEP64 2 WEP128 3 TKIP 4 AES CCMP Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 3 3 AT AGSM Security Mode Syntax AT AGSM lt smode gt lt store_in_startup_database gt lt CR gt AT AGSM Input and Response Parameters smode store_in_startup_database Responses lt CR gt lt LF gt AGSM lt smode gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt
51. l simply connect to the next device configured with AT ADWRL Write Roaming List 2 31 Reserved Reserved Reserved Reserved Reserved Reserved Roaming RSSI diff threshold default 10 When the difference between the connected AP RSSI and the RSSI from the best AP from background scan exceeds this threshold a roaming handover is done BDP status report interval default 5000ms Time between multicast status reports from Slave Master Available devices BDP Slave polling Master interval default 500ms BDP Master check Slave watchdog default 10000ms If the Master receives no status report from the Slave within this time the Slave is marked as dead BDP Available check interval default 7000ms Time before an Available device switches to Master if it detects no Master device BAT C Release 01 08 2012 Responses 1116 1117 1118 1119 Miscellaneous 1200 1201 1202 1203 1204 1205 1206 1207 1208 BAT C Release 01 08 2012 Description BDP Slave polling Master watchdog ticks default 3 Number of Slave polling Master intervals before the Slave considers the Master to be dead BDP role switch interval default 2000ms Time to wait for a role switch acknowledgement BDP role switch watchdog ticks default 3 Number of role switch intervals before the role switch is considered a failure Reserved Use this register to configure the time in seconds before the LEDs turn off
52. lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 30 Description Use this command to write the Operational Mode i e if the device is operating in an Ad Hoc environment or as a predetermined infrastructure with access points Use this command to read the current Operational Mode Type Value Integer 1 Managed infrastructure default 2 Ad Hoc Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 3 5 AT AGFP Encryption Authentication Key Syntax Description AT AGFP lt key gt lt store_in_startup_database gt lt Use this command to write the CR gt Input Parameters key store_in_startup_database Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 encryption authentication key for index 1 This command is a shortcut for AT AGFPWI 1 lt key gt lt store_in_startup_databa se gt Type Value String Use any string value for this setting In
53. lt LF gt AGAFP lt keyindex gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description Use this command to write the active encryption authentication key Use this command to read the current active encryption authentication key Type Value Integer Valid integers for this function are 1 4 1 default Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 33 3 8 AT AGUN Username Syntax AT AGUN lt username gt lt store_in_startup_database gt lt CR gt AT AGUN Input and Response Parameters username store_in_startup_database Responses lt CR gt lt LF gt AGUN lt username gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 34 Description Use this command to write the UserName Use this command to read the current the UserName Type Value String Use this name for identification on authentication
54. mand BAT C Release 01 08 2012 Responses Description lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 7 4 AT AMMP Max Output Power Syntax Description AT AMMP lt max_power gt Use this command to write the max power settings lt store_in_startup_database gt lt CR gt AT AMMP Use this command to read the current max power setting Input and Response Parameters Type Value max_power Integer This setting is the actual dBm The valid range is between 14 15 store_in_startup_database Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AMMP lt max_output_power gt The device displays the current parameter setting lt CR gt lt LF gt OK lt CR gt lt LF gt followed by OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command BAT C 61 Release 01 08 2012 7 5 AT AMWS Watchdog Settings Syntax AT AMWS lt reserved1 gt lt inactivity_timeout gt lt conn
55. nfigure Client mode The device issues a reset of the module 1 Configure Ethernet Bridge mode 2 Reserved 3 Configure Multi Client mode 0 Client mode 1 Ethernet Bridge Mode 3 Multi Client mode 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 7 23 AT AMEO Set External Digital Output Syntax AT AMEO lt value gt lt CR gt Input Parameters Type Description Use this command to set External digital Output to value Value value integer 0 LOW Ground OV DC 1 HIGH The voltage will be set to the corresponding value on the power connector A coded male M12 pinning number 5 typical 12 24 V DC Responses Description lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 7 24 AT AMSTAT Read Current Status Syntax AT AMSTAT lt level gt lt id gt lt CR gt Input and Response Type Parameters level integer BAT
56. nput and Response Type Parameters ch Integer store_in_startup_ database Integer 40 Description Use this command to write the channel number to use Use this command to read the current channel number in use Value Write the channel list to use This list also specifies the scan order The number of channels to specify is dependent on the regulatory domain set See command AMRD for details about regulatory domains and below for channel list lengths If you don t want to use all positions pad list with zeros Channel list length for the regulatory domains World 11 FCC 11 ETSI 13 U NII band 1 4 U NII band 2 4 U NII band 2 extended 11 Example 1 If regulatory domain is set to World U NII band 1 2 then the number of channels to specify is 11 4 4 19 AT AGCL 6 1 11 2 7 4 9 3 8 5 10 36 40 44 48 52 56 60 64 1 Example 2 To use only channel 1 6 and 11 in regulatory domain World AT AGCL 1 6 11 0 0 0 0 0 0 0 0 0 0 0 1 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database BAT C Release 01 08 2012 Responses lt CR gt lt LF gt AGCL lt ch1 gt lt ch2 gt lt chN gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 3 15 AT AGSCAN Syntax AT AGSCAN AT AGSCAN lt ssid gt
57. nses Description lt CR gt lt LF gt ANDHCP lt on gt The device displays the current parameter setting followed by OK lt CR gt lt LF gt OK lt CR gt lt LF gt after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command BAT C 45 Release 01 08 2012 4 3 AT ANHN Hostname Syntax AT ANHN lt hostname gt lt store_in_startup_database gt lt CR gt AT ANHN Input and Response Parameters hostname store_in_startup_database Responses lt CR gt lt LF gt ANHN lt hostname gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 46 Description Use this command to write the HostName used with the dynamic DNS Use this command to read the current HostName used with the dynamic DNS Type Value string Use any string default BAT C integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command T
58. ponse Parameters ssid store_in_startup_database Responses lt CR gt lt LF gt AGSSID lt ssid gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Use this command to read the current Network Name SSID of the access point Type Value String Use any string value max length 32 bytes Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 37 3 12 AT AGRSS RSSI Value Syntax Description AT AGRSS Use this command to read the current RSSI value of the connection If the module is not connected it returns an ERROR Response Type Parameter rssi Integer Responses lt CR gt lt LF gt AGRSS lt rssi gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 38 Value This is the RSSI value 128 10 where value is dBm value Use this command after the device establishes a connection otherwise the response to this read command is an error message Description This res
59. ponse indicates a successful execution of the write command This response indicates unsuccessful execution of the write command BAT C Release 01 08 2012 3 13 AT AGCH Channel Number Syntax Description AT AGCH lt ch_no gt lt store_in_startup_database gt lt CR gt Use this command to write the Channel AT AGCH Input and Response Parameters ch_no store_in_startup_database Responses lt CR gt lt LF gt AGCH lt ch_no gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 number to use Use this command to read the current CHannel number in use Type Value Integer 0 Auto default select from defined channel list gt 0 Channel to use Available channels depending on regulatory domain setting Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 39 3 14 AT AGCL Channel List Syntax AT AGCL lt ch1 gt lt ch2 gt lt chN gt lt store_in_startup_database gt lt CR gt AT AGCH I
60. ponses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 2 6 ATE Echo On Off Syntax ATE lt echo_on gt lt CR gt ATE Input and Response Parameters echo_on BAT C Release 01 08 2012 Description Use this command to configure the Ethernet Port Adapter to Echo the incoming characters Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command Description Use this command to configure the Ethernet Port Adapter to Echo the incoming characters Use this command to read the current Echo setting Type Description integer 0 The echo characters function is off during command state and online command state 1 Unit echoes characters during command state and online command state 11 Responses lt CR gt lt LF gt echo_on lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 2 7 ATQ Result Codes On Off Syntax ATQ lt cresult_off gt lt CR gt ATQ Input and Response Parameters result_off 12 D
61. power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 43 4 Network Layer Commands 4 1 AT ANIP IP Settings Syntax AT ANIP lt ip_addr gt lt netmask gt lt gw gt lt store_in_startup_database gt lt CR gt Description Use this command to write the system information i e IP address netmask and gateway IP The device requires a restart to activate the new configuration The AT ANIP Command returns the old system information until you restart the module AT ANIP Use this command to read the currently stored IP address and system information Use the AT AMSTAT to read the current IP address Input and Response Type Value Parameters ip_addr IP_Addr IP address for the device default 172 23 56 99 netmask IP_Addr Netmask for the device default 255 255 255 0 gw IP_Addr The IP address of the gateway default 172 23 56 99 store_in_startup_database integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt A
62. r Use this command to read the current escape character Type Description integer esc_char is the ASCII value of the new escape character i e 47 equals The default character is Note The escape sequence will be Therefore enter the character three times Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 13 2 9 ATS3 Command Line Termination Character Syntax ATS3 lt line_term gt lt CR gt Description Use this command to write command line termination character This setting changes the decimal value of the character recognized by the DCE from the DTE to terminate an incoming command line The DCE also generates this as part of the header trailer and terminator for result codes and information text along with the S4 parameter Use the previous value of S3 to determine the command line termination character for entering the command line containing the S3 setting command However the result code issued uses the value of S3 as set during the processing of the command line For example if S3 was previously set to 13 and you enter the command line ATS3 30 You use the CR character 13 to terminate the command line but the result code issued will use the character with
63. successful execution of the write command 7 16 AT AMSEID SNMP Enterprise ID Syntax AT AMSEID lt CR gt Response Parameters id 72 Description Use this command to read the current SNMP Enterprise Id Type Value Integer This is an integer representing your company BAT C Release 01 08 2012 Responses lt CR gt lt LF gt AMSEID lt id gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 7 17 AT AMTL TCP Listener Syntax AT AMTL lt port gt lt enable gt lt store_in_startup_database gt lt CR gt AT AMTL Input and Response Type Parameters enable Integer port Integer store_in_startup_database Integer Responses lt CR gt lt LF gt AMTL lt port gt lt enable gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command Description Use this command to enable or disable the TCP Listener Use this command to read the current TCP Listener activation status Value 0 Disables TCP Listener 1 Enables TCP Listener When enabled it will always enter at mode at startup TCP port to listen for incoming connections 0 The setting is v
64. t LF gt This response indicates an unsuccessful execution of the write command BAT C 35 Release 01 08 2012 3 10 AT AGCFP Certificate Fingerprint Syntax Description AT AGCFP lt fingerprint gt Use this command to write the Certificate Finger Print lt store_in_startup_database gt lt CR gt AT AGCFP Use this command to read the current Certificate Finger Print Input and Response Parameters Type Value fingerprint Octet This is a 20 bytes octet string representing the String fingerprint quotes shall not be used store_in_startup_database Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Responses Description lt CR gt lt LF gt AGCFP lt fingerprint gt The device displays the current parameter setting followed by lt CR gt lt LF gt OK lt CR gt lt LF gt OK after entering a successful read command lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a successful execution of the write command lt CR gt lt LF gt ERROR lt CR gt lt LF gt This response indicates an unsuccessful execution of the write command 36 BAT C Release 01 08 2012 3 11 AT AGSSID Network Name SSID Syntax AT AGSSID lt ssid gt Description Use this command to write the Network Name SSID of lt store_in_startup_database gt lt CR gt the access point AT AGSSID Input and Res
65. t LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description Use this command to read the current default peer Value The command returns a value between 0 and the response from AT ADMRP 1 Address to the service on the remote peer In the form of lt protocol gt ipaddr port i e tep 172 23 56 1 5130 Ignored by the BAT C 0 Unused 1 Connect on data Connects when transmitting data then remains connected 2 Always connected Connects right after power on This parameter is for future use A string with a user defined name of the peer Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command 51 5 6 AT ADWDRP Write Remote Peer Information Syntax AT ADWDRP lt peer_id gt lt address gt lt conn_scheme gt lt reserved gt lt name gt lt store_in_startup_database gt Input Parameters peer_id address conn_scheme reserved name store_in_startup_database Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 52 Type Integer String Integer Integer String Integer Description Use this command to write information for a remote peer Value This is any value between 0 and the response from AT
66. t cmd1 gt lt CR gt lt LF gt lt cmd2 gt lt CR gt lt LF gt The device sends a response to the host for lt CR gt lt LF gt OK lt CR gt lt LF gt every successful supported command followed by an Ok lt CR gt lt LF gt OK lt CR gt lt LF gt This response indicates a _ successful lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 execution of the write command This response indicates an unsuccessful execution of the write command 2 3 AT amp F Restore to Factory Settings Syntax Description AT amp F lt CR gt This command instructs the device to set all parameters to their defaults as specified by the manufacturer Factory Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 2 4 AT amp FO Restore to Factory Settings Syntax AT amp FO0 lt CR gt Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 10 Description See the description of the AT amp F Restore to Factory Settings command Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 2 5 ATE Echo Off Syntax ATE lt CR gt Res
67. teger 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 31 3 6 AT AGFPWI Write Encryption Authentication Key with Index Syntax AT AGFPW l lt keyindex gt lt key gt lt store_in_startup_database gt lt CR gt Input Parameters keyindex key store_in_startup_database Responses lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 32 Description Use this command to write the encryption authentication key Type Value Integer The valid integers are 1 4 String Use any string value for this setting Integer 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 3 7 AT AGAFP Active Encryption Authentication Key Syntax AT AGAFP lt keyindex gt lt store_in_startup_database gt lt CR gt AT AGAFP Input and Response Parameters keyindex store_in_startup_database Responses lt CR gt
68. the third indicated by A and B will be 3 and so on See the product guide for more details Use this command to read the current SMART button function list Value 0 End Smart mode function list 1 15 SMART functionality 1 Exit Smart mode Reset to factory defaults Reset IP settings to factory defaults Wait for Automatic configuration Ad Hoc Initiate Automatic configuration Ad Hoc Wait for Automatic configuration Profinet Ad Hoc Initiate Automatic configuration Profinet Ad Hoc Wait for Automatic configuration Managed mode 9 Initiate Automatic configuration Managed mode 10 Initiate Automatic configuration Managed mode wired 11 Configure Client mode 12 Initiate Automatic configuration Ad Hoc Multipoint 13 Reserved 14 Reserved 15 Enable DHCP server 16 255 Reserved Default 15 2 3 4 5 6 7 8 9 10 11 12 CON ODO W P 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database BAT C Release 01 08 2012 Responses lt CR gt lt LF gt AMSMFL lt smart_mode_1 gt lt smart_mode_2 gt lt smart_mode_3 gt lt smart_mode_4 gt lt smart_mode_5 gt lt smart_mode_6 gt lt smart_mode_7 gt lt smart_mode_8 gt lt smart_mode_9 gt lt smart_mode_10 gt lt smart_mode_11 gt lt smart_mode_12 gt lt smart_mode_13 gt lt smart_mode_14 gt lt smart_mode_15 gt
69. this command to enable or disable the Link Configuration Receiver Use this command to read the current Link Configuration Receiver status Value 0 Disables Link Config Receiver 1 Enables Link Config Receiver Ethernet type that will be passed up the AT parser 0 The setting is valid for the current power cycle 1 The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database Description The device displays the current parameter setting followed by OK after entering a successful read command This response indicates a successful execution of the write command This response indicates an unsuccessful execution of the write command 77 7 22 AT ACEW Configure Mode Syntax AT ACEW lt mac_addr gt lt enter gt lt store_in_startup_database gt lt CR gt AT ACEW Input and Response Parameters mac_addr enter mode store_in_startup_database Responses Type MAC_Addr Integer Integer integer lt CR gt lt LF gt ACEW lt mac_addr gt lt mode gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 78 Description Use this command to configure and enter Client mode Use this command to read the current Wireless LAN MAC address and mode Value MAC address to use in Client and Multi Client mode Ignored if second parameter 1 0 Co
70. tion between power cycles by updating the settings database Description This response indicates a successful execution of the write command Response to an unsuccessful execution of the write command 55 5 10 AT ADLNK Read WLAN link status Syntax Description AT ADLNK lt CR gt Use this command to read the current WLAN link status Response Parameters Type Value link_status integer 0 Not associated 1 Associated bssid Mac_Addr BSSID of the WLAN network or N A if not associated Responses Description lt CR gt lt LF gt ADLNK lt link_status gt lt bssid gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt 56 The device displays the current parameter setting followed by OK after entering a successful read command This response indicates an unsuccessful execution of the write command BAT C Release 01 08 2012 6 Informational Commands 6 1 AT AILBA Read Local MAC Address Syntax AT AILBA lt CR gt Response Parameters mac_addr Responses lt CR gt lt LF gt AILBA lt mac_addr gt lt CR gt lt LF gt OK lt CR gt lt LF gt lt CR gt lt LF gt ERROR lt CR gt lt LF gt BAT C Release 01 08 2012 Description This command reads the MAC Address of the local device Type Value Mac_Addr This is the Local MAC address Description The device displays the current parameter setting followed by OK after entering a successful read comman
Download Pdf Manuals
Related Search
Related Contents
ProForm 831.29555 User's Manual User`s manual TensioClinic TensioMed™ Symantec Backup Exec™ System Recovery Granular Restore EZ CAM XR™ Instruction Sheet EZ Cam XR Adora SL - V Gefen GTB-UHD2IRS-ELRPOL-BLK ぷよぷよ!!クエスト かんたんガイド データシート CATALOGUE GENERAL HF-LPT100 Low Power WiFi Module User Manual Copyright © All rights reserved.