        Micro Motion Coriolis Interface Module User Manual
         Contents
1.     TMR Post Mist Adjust  Delay  143 TBR Control    144 SMV Stiffness Setpoint    145 TBR Drive Gain  Threshold    TMR Drive Gain  Threshold    146 Flow Damping    147 Mass Flow Cutoff    148 Density Calibration  Point 1  D1     Revised August 2015    Access    R W    R W    R W    R W    R W    R W    R W    R W    R W    System  or User  Update  User and  System    User and  System  User and  System    User and  System  User and  System    User and  System    User and  System  User and  System    User and  System    Data  Type  UNIT16    UNIT16    UINT8    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    Length    Range    5 to 30    5 to 30    0 127    Any floating point  value   Any positive   floating point  number   Any positive   floating point  number   0 60 seconds    0 to High Mass  Flow Limit of  Sensor  0 5 g cc    Default    0    0 0025     0 4    0    0 0    0 0    0 0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    For TBR  the number of seconds  back in time to calculate density  LMV   For TMR  the number of seconds  the post mist is delayed   TBR Control  Bit 0  Initial Action   0   Hold Last Value   1   Set TBR Active Status   Only   Bit 1  Timeout Action   0   Show Actual Values   1   Alarm  Bit 2  Drive Averaging   0   1 Second   1   4 Seconds  Bit 3  Affects flow   0   Yes   1 No  Bit 4  Affects Density   0   Yes   1 No  Bit 5  Timeout Alarm Type   0   Slug F
2.     UNIT8    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    Length    4    Range    Any positive  floating point  number  0 1    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Default    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Amount of mass accumulated by  the module  This accumulator rolls  over at 1 000 000 0   The flow direction  as read from  the meter     0   Forward  Direct    1   Reverse   The volume accumulated in the  current contract day  Volume units  are determined based on the  configuration of the meter    The volume accumulated in the  previous contract day  Volume  units are determined based on the  configuration of the meter    The volume accumulated in the  previous month  Volume units are  determined based on the  configuration of the meter   Amount of reverse volume  accumulated by the module  This  accumulator rolls over at  1 000 000 0   The mass accumulated in the  current contract day  Mass units  are determined based on the  configuration of the meter    The mass accumulated in the  previous 
3.    1 00    1 00    1 00    Description of functionality and  meaning of values    The volume accumulated during  the current  in progress  or most  recently completed dump cycle   Volume Total units are determined  based on the configuration of the  meter     The maximum density during the  current  in progress  or most  recently completed dump cycle   Density units are determined  based on the configuration of the  meter     The maximum drive gain during  the current  in progress  or most  recently completed dump cycle   Drive Gain units are percent     The minimum density during the  current  in progress  or most  recently completed dump cycle   Density units are determined  based on the configuration of the  meter     The minimum drive gain during the  current  in progress  or most  recently completed dump cycle   Drive Gain units are percent     The number of dump cycles that  have occurred in the current  contract day     The volume accumulated in the  current contract day  Volume Total  units are determined based on the  configuration of the meter     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       28 Volume Total Units    Name    29 Today   s Total  Accumulated Mass    30 Mass Total Units    31 Yesterday   s Total  Number of Dump  Cycles    32 Yesterday s Total  Accumulated Volume    33 Yesterday s Total  Accumulated Mass    34 Mont
4.    Click to begin the verification process     Note  The label on this button changes with the  state of the verification  Once the  verification begins  the label changes to  Abort     3  Click Apply to save any changes you have made to this screen     4  Proceed to Section 3 1 5 to configure the TBR TMR tab     Revised August 2015    23    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 5 Coriolis Setup and Values     TBR TMR    Transient bubble remediation  TBR  applies only to liquid flow   transient mist remediation  TMR  applies only to gas flow  This screen  displays only if the connected Micro Motion Coriolis device has the  factory enabled TBR or TMR feature  Otherwise the message Feature  not supported on this Micro Motion meter displays  Additionally  If you  are connecting to a Micro Motion transmitter  models 1500  1700  2500   2700  or 3000 series   this tab is not available     Use this screen to configure and view the TBR and TMR settings for the  selected Coriolis meter     Note  The TBR TMR screen shown in Figure 10 is a composite   showing both TBR and TMR values  It is only an example for  documentation purposes and would not occur in a live system     To access this screen   1  Select the TBR TMR tab  The TBR TMR screen displays               E ROCLINK 800    Coriolis Setup and Values   FB107  Sto       File Edit View ROC Configure Meter Utilities Tools Window Help            X  Dee Qt Ww Se OM        Poi
5.    From the Directory Tree  double click Application Module   Double click MMI Coriolis Intfc   Double click Display  66  Coriolis Setup and Values     Double click 1     Meter  1  The Coriolis Setup and Values screen  displays     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107           E pd    ROCLINK 800    Coriolis Setup and Values   FB107   Soa    File Edit View ROC Configure Meter Utilities Tools Window Help      eI x  Dei Gt t Wiha Mihi s 4 Ol  amp        Point Number   EA M Meter Tag   ECP TBR 2    General   Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Config  Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR      Communications Micro Motion Coriolis Licensed Features  Modbus Address  313    2 Poll Mode    PYR   Production Volume Reconciliation  Poll Timeout   1 0 seconds a Enabled I SMY   Smart Meter Verification  eels  7 TBR  Liquid    Transient Bubble Remediation    Number of Retries   3  Actual Poll Period   0 95 seconds  Con Stu URSA lll    Meter Mode     Continuous Flow C Dump Cycle    I TMR  Gas    Transient Mist Remediation    Flow Direction Mode  17     Forward Only C Reverse Only    Bi Directional    Live Coriolis Values    Forward                 Volume FlowfR ate  253    US gal hour  Mass Flow ate  247    kg hour  Sensor Tempespture  251    F  Flowing Dansity  249    afem 3  DrivefGain  291    B     Print Save As Auto Scan Update Close       
6.    Reference    This manual assumes that you are familiar with the FB107 and the  ROC800 ROC800L and its configuration  For more information  refer  to the following manuals       FloBoss 107 Flow Manager Instruction Manual  part  D301232X012       ROC800 Series Remote Operations Controller Instruction Manual   part D301217X012       ROCLINK    800 Configuration Software User Manual  for  FloBoss 107   part D301249X012       ROCLINK    800 Configuration Software User Manual  for  ROC800 Series   part D301250X012       ROCLINK     800 Configuration Software User Manual  for  ROCSOOL   part D301246X012      1 2 Product Overview    The MMI Coriolis Interface module enables the FB107 or the  ROC800 ROC800L to communicate directly with the core processor in  up to 6  4 on the FB107  Micro Motion Coriolis meters on the same  EIA 485  RS 485  communications port   The module provides its own  communications port for this purpose   The module serves as an  interface between Coriolis meters  transmitters  and the FB107 or  ROC800 ROC800L  retrieving  validating  and then processing the data     By supporting multiple core processors or transmitters at one time  the  module eliminates the need to have one transmitter for each core  processor  Additionally  it removes the need for a water cut probe in a 2   phase separator for liquid output  Finally  it manages transient mist  remediation  TMR   transient bubble remediation  TBR   production  value reconciliation  PVR   meter zeroing  a
7.   4 0 235959  4 Any positive  floating point  number    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The drive gain value recorded  when the maximum density value  for the current contract day  occurred  Drive gain units are  percent     The volume rate recorded when  the maximum density value for the  current contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the minimum density value  for the current contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The end time of the dump cycle in  which the minimum density value  for the current contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the minimum  density value for the current  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The minimum density value  recorded during the current  contract day  Density units are  determined based on the  configuration of the meter     55    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    56    Parm       48    49    50    51    52    53    Name    Drive Gain at Today   s  Minimum Density    Volume Rate at  Today   s Minimum  Density    Yesterday   s
8.   Drive Gain Cycle End  Time    Yesterday s Minimum  Drive Gain Time of  Occurrence    Yesterday   s Minimum    Drive Gain    Density at Yesterday s  Minimum Drive Gain    Volume Rate at  Yesterday   s Minimum  Drive Gain    Meter Zero    Access    R O    R O    R O    R O    R O    R W    System  or User  Update  System    System    System    System    System    User and  System    Data  Type  UINT32    UINT32    FL    FL    FL    UINT8    Length    Range    0 235959    0 235959    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    0 1    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The end time of the dump cycle in  which the minimum drive gain  value for the previous contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the minimum  drive gain value for the previous  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The minimum drive gain value  recorded during the previous  contract day  Drive gain units are  percent     The density value recorded when  the minimum density value for the  previous contract day occurred   Density units are determined  based on the configuration of the  meter     The volume rate recorded when  the minimum drive gain value for  the previous contract day occurred   Volume units
9.   FLOAT  FLOAT  FLOAT    FLOAT    FLOAT  FLOAT    FLOAT    FLOAT    UINT16    UINT16  FLOAT    FLOAT  FLOAT    FLOAT    Length  4    4    ine     Range  0 5 g cc  1000   50000  1000   50000   20 to 20    Any positive  floating point  number  0 5 g cc    0 5 g cc    Any positive  floating point  number  Any positive  floating point  number  0 65535    0 65535   240 to 450 C     1 5 to 10000 BAR     0 1 to 0 1     0 1 to 0 1    Default    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Density Calibration Point 2  D2   Tube Period   D1  K1   Tube Period   D2  K2     Density Temperature Correction   DT   Density Flow Correction  FD     Slug Flow High Density Limit  g cc   Slug Flow Low Density Limit  g cc     The maximum Mass flow rate that  the sensor can detect     The maximum volume flow rate  that the sensor can detect     Identifies the type of device  attached to the module  Valid  values are     40   700 Core Processor   50   800 Enhanced Core  Processor   36   1500 Transmitter   37   2500 Transmitter   41   1700 Transmitter   42   2700 Transmitter   65   3000 series transmitter  Manufacturer ID   External temperature input value    External pressure input value  Pressure correction factor for mass  flow    Pressure correction factor for  density    Revised August 2015    Micro Motio
10.   gt            EERE 251 Pw          Figure 5  Coriolis Setup and Values    Notes      The Coriolis Setup and Values screen has a tab format  Sections  3 1 1 through 3 1 71 discuss the requirements for each tab on the  Coriolis Setup and Values screen      Two fields  Point Number and Meter Tag  at the top of the  screen appear on all tabs  see Figure 5       For many fields on these screens  bracketed numbers follow the  field labels  see Figure 5   These numbers identify the specific  Modbus register in the Coriolis meter   s core processor that  provides the value     1  Review the values in the following fields     Field Description  Point Number Selects the Coriolis meter to configure  Click  v to display a drop down menu of all meters     Meter Tag Sets a short  10 character  identifier for the  selected Coriolis meter     Note  The default value for the Point Number field is x     Meter x   corresponding to the number of meters your device supports   1     Meter 1  2     Meter 2  and so on   Similarly  Meter    Revised August 2015 11    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Tag is the default value for the Meter Tag field until you  provide a value  The values displayed in the examples in this  documentation are for illustrative purposes only and do not  reflect the factory default     2  Click Apply to save any changes you have made to this screen     3  Proceed to Section 3 1 1 to configure the General tab     
11.  291   6 491933          Print Save As Auto Scan Update Close Apply    ep  gt   DERE 251 Px                Figure 6  Coriolis Setup and Values     General Tab    1  Review the values in the following fields     Field Description  Communications  Modbus Address Enter the Modbus address of the target Coriolis    device  Valid values are 1 15  32   47  64 79    and 96 110  The default is 255    Note  The Modbus address you select must be  unique and not assigned to any other  meter connected to this module  That is   you cannot select Address 2 for meter 2  if that address is already assigned to  meter 1     13    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field  Poll Timeout    Number of Retries    Actual Poll Period    Comm Status    Poll Mode    Meter Mode    Flow Direction Mode    Live Coriolis Values    14    Description    Sets the amount of time  in seconds  the  program waits to receive a response from a  Coriolis meter  If a response is not received  within the specified time period  the message is  retried or the meter is marked with a response  timeout status in the Comm Status field     Sets the number of times the program attempts  to successfully communicate with the selected  Coriolis meter before issuing a response  timeout status in the Comm Status field  If a  meter does not respond within the specified  number of retries  the program attempts to  restore communications with the meter every  10 seconds     Thi
12.  Byte 0   Seconds    The maximum density value  recorded during the previous  contract day  Density units are  determined based on the  configuration of the meter     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       54 Yesterday   s Average  Density    Name    55 Drive Gain at  Yesterday   s Maximum  Density    56 Volume Rate at  Yesterday   s Maximum  Density    57 Yesterday   s Minimum  Density Cycle Start  Time    58 Yesterday   s Minimum  Density Cycle End  Time    59 Yesterday   s Minimum  Density Time of  Occurrence    Revised August 2015    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    FL    FL    UINT32    UINT32    UINT32    Length Range  4 Any positive  floating point   number  4 Any positive  floating point   number  4 Any positive  floating point   number   4 0 235959   4 0 235959   4 0 235959    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The average density value during  active dump cycles recorded  during the previous contract day   Density units are determined  based on the configuration of the  meter     The drive gain value recorded  when the maximum density value  for the previous contract day  occurred  Drive gain units are  perc
13.  FloBoss    107     Field  Volume Flow Rate    Mass Flow Rate    Sensor Temperature    Flowing Density    Drive Gain    Micro Motion  Coriolis Licensed  Features    Description    This read only field shows the current volume  flow rate  as reported by the meter  Configure  display units using the Units Configuration tab     The Flow Direction Mode you select controls  the values shown in this frame  Values in the  Forward column display only if you select  Forward Only or Bi Directional  Values in the  Reverse column display only if you select  Reverse Only or Bi Directional     This read only field shows the current mass  flow rate  as reported by the meter  Configure  display units using the Units Configuration tab     The Flow Direction Mode you select controls  the values shown in this frame  Values in the  Forward column display only if you select  Forward Only or Bi Directional  Values in the  Reverse column display only if you select  Reverse Only or Bi Directional     This read only field shows the current  temperature value retrieved from the meter   You configure the display units using the Units  Configuration tab     This read only field shows the current density  value retrieved from the meter  Configure  display units using the Units Configuration tab     This read only field shows  as a percentage   the current drive gain value     This read only field shows the specific  licensed features of the Coriolis meter which  are currently active     2  Click Apply to
14.  Mass Flow Meter Factor  279    1 0  Density Meter Factor  283   10 9    Flow Calibration Factor  72      5 02534 38    Temperature Calibration Factor  80      1 00000T 00000    Density Temp Correction  DT   163    j5  Density Flow Correction  FD   303    330 7675  Flow Calibration Pressure  271    bo 8     Flow Damping  189    o8             Print Save As Auto Scan Update Close Apply   gt    EERE 231 Pm                Figure 7  Coriolis Setup and Values     Calibration Tab    2  Review   and change as necessary   the values in the following  fields     16    Field  Volume Flow Cutoff    Mass Flow Cutoff    Volume Flow Meter  Factor    Mass Flow Meter  Factor    Description    Sets the Volume Flow Cutoff value for the  target Coriolis meter  The default is 0     Sets the Mass Flow Cutoff value for the target  Coriolis meter  The default is 0     Sets the Volume Flow Meter Factor value for  the target Coriolis meter  Valid values are from  0 8 to 1 2  The default is 0     Sets the Mass Flow Meter value for the target  Coriolis meter  Valid values are from 0 8 to 1 2   The default is 0     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Revised August 2015    Field  Density Meter Factor    Flow Calibration  Factor    Temperature  Calibration Factor    Density Temp  Correction  DT   Density Flow  Correction  FD   Flow Calibration  Pressure    Flow Damping  Density Calibration    Points    Tube Periods    Slug 
15.  Maximum  Density Cycle Start  Time    Yesterday   s Maximum  Density Cycle End  Time    Yesterday s Maximum  Density Time of  Occurrence    Yesterday s Maximum  Density    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    FL    UINT32    UINT32    UINT32    FL    Length Range  4 Any positive  floating point  number  4 Any positive  floating point  number  4 0 235959  4 0 235959  4 0 235959  4 Any positive  floating point  number    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The drive gain value recorded  when the minimum density value  for the current contract day  occurred  Drive gain units are  percent     The volume rate recorded when  the minimum density value for the  current contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the maximum density value  for the previous contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The end time of the dump cycle in  which the maximum density value  for the previous contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the maximum  density value for the previous  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes 
16.  Print Save As Auto Scan Update Close  Kh    gt    EERE 249P                   Figure 15  Coriolis Setup and Values     Dump Cycle Min Max Data Tab    2  Review the values in the following fields     Field Description  Density Min Max Occurrences    Cycle Start Time These read only fields show the start time of the  dump cycle in which the minimum and the  maximum density values were recorded during  the current and the previous contract day     38 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Revised August 2015    Field  Cycle End Time    Time of Occurrence    Min Max Density    Value    Average Density    Drive Gain Value    Volume Rate    Description    These read only fields show the end time of the  dump cycle in which the minimum and the  maximum density values were recorded during  the current and the previous contract day     These read only fields show the time at which  the minimum and the maximum density values  were recorded during the current and the  previous contract day     These read only fields show the minimum and  the maximum density values recorded during the  current and the previous contract day  Units are  configured in the Units Configuration tab    These read only fields show the average density  for the day at the moment when the minimum  and the maximum density values were recorded  during the current and the previous contract day   Units are configured in the Units Configurat
17.  The density value recorded when  the minimum drive gain value for  the current contract day occurred   Density units are determined  based on the configuration of the  meter     The volume rate recorded when  the minimum drive gain value for  the current contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the maximum drive gain  value for the previous contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The end time of the dump cycle in  which the maximum drive gain  value for the previous contract day  was recorded    Byte 3   Unused   Byte 2   Hours   Byte 1   Minutes   Byte 0   Seconds    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       78    79    80    81    82    83    Name    Yesterday   s Maximum  Drive Gain Time of  Occurrence    Yesterday   s Maximum  Drive Gain    Yesterday   s Average  Drive Gain    Density at Yesterday s  Maximum Drive Gain    Volume Rate at  Yesterday   s Maximum  Drive Gain    Yesterday   s Minimum  Drive Gain Cycle Start  Time    Revised August 2015    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  UINT32    FL    FL    FL    FL    UINT32    Length Range  4 0 235959  4 An
18.  The end time of the dump cycle in  which the maximum density value  for the current contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the maximum  density value for the current  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The maximum density value  recorded during the current  contract day  Density units are  determined based on the  configuration of the meter     The average density value during  active dump cycles recorded  during the current contract day   Density units are determined  based on the configuration of the  meter     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       42    43    44    45    46    47    Name    Drive Gain at Today   s    Maximum Density    Volume Rate at  Today   s Maximum  Density    Today   s Minimum  Density Cycle Start  Time    Today   s Minimum  Density Cycle End  Time    Today   s Minimum  Density Time of  Occurrence    Today   s Minimum  Density    Revised August 2015    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    FL    UINT32    UINT32    UINT32    FL    Length Range  4 Any positive  floating point  number  4 Any positive  floating point  number  4 0 235959  4 0 235959
19.  Total Mass   9 92279 6 409236 16 33211  16 33211 bs  Accumulated Volume During Trickle Flow  10 0 bo   Bbls  Accumulated Mass During Trickle Flow   0    00 Ibs          Print Save As Auto Scan Update Close Apply     gt    EERE 2 34PM       Revised August 2015       Figure 13  Coriolis Setup and Values     Values Tab    31    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     32    2  Review the values in the following fields     Field  Reset Totals  Contract Hour    Reset Totals    Description    This read only field shows the contract hour  as configured on the ROC  gt  Information  screen     Click to clear all totals and reset all minimum  and maximum values stored in the module     Totals  Forward Only  Reverse Only  Bi Directional     Forward Total  Volume    Forward Total Mass    These read only fields show the volumes  accumulated in the current contract day   Today   in the previous contract day   Yesterday   and in the current month   Monthly   The value in the Accumulated field  provides a running total for all dump cycles  is  updated after the completion of a dump cycle  and during trickle flow  and rolls over at  1 000 000 units  Configure units using the  Units Configuration tab     Once the contract day is over  the value in the  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These fields display only if you select  Continuous as 
20.  UINT8    UINT8    FL  FL    Length    10    A    Range Default Version  0x20     0x7E for Logical 0   1 00  each ASCII    Meter  1      character Logical 1       Meter  2      Logical 2       Meter  3      Logical 3       Meter  4     For ROC800   Logical 4    Meter  5  Logical 5    Meter  6  1   15  255 1 00  32  gt  47   64  gt  79   96  gt  110  0 1 0 1 00  0 255 3 1 00  0 5 15 0 1 0 1 00  Any positive 0 1 00  floating point  number    Description of functionality and  meaning of values    Point Type Description    Modbus address of the target  Coriolis meter  Note this address  cannot be changed to a value that  is in use by another logical  instance     Enable communication with the  target Coriolis meter     0   Polling Disabled  1   Polling Enabled    The number of times  communication with a Coriolis  meter will be retried before a  response timeout in the Comm  Status parameter is set     Poll timeout    The time between polls to a meter  in seconds     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System  BA Name Access or User z AA  Update yp  6 Comm Status R O System UINT8 1 0 10 0 1 00    Description of functionality and    Length Range Default Version meaning of values    Current communication status with  the target meter     0   Communication Disabled   1   Communicating   2   Configuring Slot Registers  3   Retrying   4   Response T
21.  are  using transmitters  you must use Micro Motion   s ProLink    software to change the comm settings on those transmitters to  match these settings        BO Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Chapter 2     Installation    General Procedure    This chapter provides instructions for installing the Coriolis Interface  module  Read Section 1 3 of this manual for program requirements  The  FB107 and the ROC800 ROC800L each support only one Coriolis  Interface module        Note  The FB107 can support only one APP 485 module  If you  already have an APP 485 based application in your FB107   consider which application is most appropriate for your needs        Installation requires that you perform a number of steps in a specific  sequence     1  Power down the FB107 or ROC800 ROC800L     Install the application module  refer to Section 2 1      Power up the FB107 or ROC800 ROC800L     2   3  Wire the module  refer to Section 2 2     4   5  Configure the module  refer to Chapter 3      2 1 Installing the Module    The application module occupies the standard footprint of an FB107 or  ROC800 ROC800L I O or communications module  Place the module  in any empty slot on the ROC800 ROC800L or FB107     To ensure that the device recognizes the module  you must perform a  warm start  ROC  gt  Flags  gt  Warm Start      2 2 Wiring the Module    Revised August 2015    Connect the Coriolis meter s  to the co
22.  are determined  based on the configuration of the  meter     Perform Meter Zero  The value of  this parameter returns to 0 once  the Start Meter process is  complete     0   No action  1   Start Meter Zero    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       90 Meter Zero Status    Name    91 Previous Meter Zero  Offset    92 New Meter Zero Offset    93 Volume Flow Cutoff    94 Volume Flow Meter  Factor   95 Mass Flow Meter  Factor    96 Density Meter Factor    97 Number of Requests  Sent to Meter    98 Number of Good  Responses    99 Number of Response  Timeouts    100 Number of Error  Responses    Revised August 2015    Access    R O    R O    R O    R W    R W    R W    R W    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System  System    System    System    System    System    System    Data  Type  UINT8    FL    FL    FL    FL  FL    FL    UINT32    UINT32    UINT32    UINT32    Length    Range    Any valid floating  point number     5 to 5 uS    0 to High Volume  Flow Limit of  Sensor  0 8   1 2    0 8   1 2    Any positive  floating point  number  0 4294967295    0 4294967295    0 4294967295    0 4294967295    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Current s
23.  configure the units used for the selected Coriolis  meter  To access this screen     1  Select the Units Configuration tab  The Unit Configuration screen             displays   E    ROCLINK 800    Coriolis Setup and Values   FB107  Soy       File Edit View ROC Configure Meter Utilities Tools Window Help       amp     x  Dee Gt H Ww MISON   2 wl 2K       Point Number   2   ECP TMR 1 v Meter Tag   ECP TMR 1    General  Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero i         Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR      Units  Volume Flow Rate Units  42     Lses  i  Mass Flow Rate Units  39     kg    Temperature Units  41     e y  Density Units  40    g em3 v   Pressure Units  44     bar a    Mass Total Units  45   Kilograms  Volume Total Units  46   Liters             Print Save As Auto Scan Update Close    X    do  gt    SOMEONES 11 15 4M                Figure 12  Coriolis Setup and Values     Units Config Tab    2  Review   and change as necessary   the values in the following    fields   Field Description  Volume Flow Rate Sets the unit of volume flow rate for the  Units selected meter  Click w to display all defined    options    Note  If you change this value  the module  resets and clears all totals  No  conversion of units occurs     Revised August 2015 29    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     30    Field    Mass Flow Rate  Units    Temperature Units    Density U
24.  fields display only if you select  Dump Cycle as the Meter Mode on the  General tab     These read only fields show the volume  accumulated while the meter was not in a  dump cycle for the current  Today  contract  day and for the previous contract day   Yesterday   The program updates these  values whenever a dump cycle is not in  progress  Rollover occurs at 1 000 000   Configure units using the Units Configuration  tab     Note  These fields display only if you select  Dump Cycle as the Meter Mode on the  General tab     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field    Accumulated Mass  During Trickle Flow    Description    These read only fields show the mas  accumulated while the meter was not ina  dump cycle for the current  Today  contract  day and for the previous contract day   Yesterday   The program updates these  values whenever a dump cycle is not in  progress  Rollover occurs at 1 000 000   Configure units using the Units Configuration  tab     Note  These fields display only if you select  Dump Cycle as the Meter Mode on the  General tab     3  Proceed to Section 3 1 9 to configure the Current Dump Cycle tab     Revised August 2015    35    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 9 Coriolis Setup and Values     Current Dump Cycle    Note  This screen is available only if you select Dump Cycle as the  Meter Mode on the General
25.  never occur  in a live system     To access this screen   1  Select the Values tab  The Values screen displays   Note       The displayed fields on this screen depend on the values you  select for Meter Mode and Flow Direction Mode in the General  Tab      The totals shown on the Values tab are based on the specified  contract hour  These totals are independent from the Force End  of Day selection  ROC  gt  Information   and are not updated  when you perform a Force End of Day        r    az  ROCLINK 800    Coriolis Setup and Values   Remote Oprtns Cntrir       File Edit View ROC Configure Gas Meters Liquid Meters Utilities Tools Window Help     E    x  Doe OF E v4 H Wi s 4ObkB Hh     Point Number   1   Meter  1 X Meter Tag   Meter  1    General  Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Config          Current Dump Cycle   Dump Cycle Min Max Data   PYR         Reset Totals Totals    Today Yesterday Monthly Accumulated    fo    Contract Hour      NOTE  Clicking this button   will clear all current  daily    and monthly totals  The   Maximum and minimum Reverse   values recorded during dump   cycles will also be reset  Total Volume   0 0 0 0 0 0 0 0 Bbls  Reset Totals Total Mass   0 0 0 0 0 0 0 0 bs          Total Mass       9 92279 6 409236 16 33211 16 33211 lbs    Forward    Total Volume  10 0 0 0 0 0 0 0 Bbls    Totals             Today Yesterday Monthly Accumulated  Number of Dump Cycles  f0 fo 0  TotalVolume   o0 joo  oo foo Bbs 
26.  retrieved  from the meter  Drive Gain units  are percent     The current status of a dump cycle   0   Complete   1   In Progress   The start time of the current  in  progress  or most recently  completed dump cycle    Byte 3   Unused   Byte 2   Hours   Byte 1   Minutes   Byte 0   Seconds   The end time of the current  in  progress  or most recently  completed dump cycle    Byte 3   Unused   Byte 2   Hours   Byte 1   Minutes   Byte 0   Seconds    51    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       21    22    23    24    25    26    27    52    Name    Current Dump Cycle  Volume Accumulated    Current Dump Cycle  Maximum Density    Current Dump Cycle  Maximum Drive Gain    Current Dump Cycle  Minimum Density    Current Dump Cycle  Minimum Drive Gain    Today   s Total Number  of Dump Cycles    Today   s Total  Accumulated Volume    Access    R W    R O    R O    R O    R O    R O    R W    System  or User  Update  System    System    System    System    System    System    System    Data  Type  FL    FL    FL    FL    FL    UINT16    FL    Length    Range    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    0 65536  Any positive    floating point  number    Default    0    Version    1 00    1 00    1 00    1 00 
27.  save any changes you have made to this screen     3  Proceed to Section 3 1 2 to configure the Calibration tab     Revised August 2015    15    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 2 Coriolis Setup and Values     Calibration Tab    Use this screen to perform and view meter calibration factors  To access  this screen     1  Select the Calibration tab  The Calibration screen displays        F  E   ROCLUINK 800    Coriolis Setup and Values   FB107     File Edit View ROC Configure Meter Utilities Tools Window Help          x    0 w amp  Gt Whale 4 Ol   KR   Point Number   1 ECPTBR2 v  Meter Tag   ECP TBR 2    General Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Contig  Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR         Meter Calibration Factors    Volume Flow Cutoff  197   11 0 Density Calibration Points Load Optimization  394   US gal hour Point 1  D1   155    0 0 g cc C Enabled   Disabled    ho Point 2  D2   157    1 0 g cc  Most Flow Cutoff  130     Correction of Mass and Density for Pressure  82   g hour    Tube Periods    Enabled   Disabled    D1  K1   159    6394 586  D2  K2   161    7405 048    Slug Flow    High Density Limit  199    5 0 g cc  Low Density Limit  201    0 0 g cc  Pressure Correction Factor  Flow  267    01  Density  269    00  External Input Values  Temperature  449   132 0  Pressure  451    6 894758    Volume Flow Meter Factor  281    1 1 
28.  tab  Dump Cycle mode applies only  to liquid flow     Use this screen to view the current dump cycle information for the  selected Coriolis meter  To access this screen     1  Select the Current Dump Cycle tab  The Current Dump Cycle  screen displays              r      ROCLINK 800    Coriolis Setup and Values   Remote Oprins Cntrir  Soa      File Edit View ROC Configure GasMeters Liquid Meters Utilities Tools Window Help     ol x  De Or v4 H ME SZORRI     Point Number    1   Meter  1 v Meter Tag   Meter  1    General   Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Config   Values          Current Dump Cycle Information  Dump Cycle Minimum Flow   foo    Bbls day  Status  Complete  Start Time  00 00 00  End Time  00 00 00    Volume Accumulated   0 0 Bbls       Minimum Maximum  Density    0 0  0 0 g cm 3  Drive Gain   0 0 0 0         Print Save As Auto Scan Update Close Apply             gt    DRENE 249P          Figure 14  Coriolis Setup and Values     Current Dump Cycle Tab    2  Review   and change as necessary   the values in the following    fields   Field Description  Dump Cycle Sets the minimum flow rate for a dump cycle  If  Minimum Flow flow is less than this value  the module    assumes the dump cycle is closed and trickle  flow accumulation is in effect     36 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field    Status    Start Time    End Time    Volume A
29.  the total number of  instances when the program has not received   a response within the timeout period from the   selected meter     This read only field shows the total number of  erroneous Modbus responses the module has  received from the selected meter     Click to reset all communication statistics  values displayed in the Communication  Statistics frame     This read only field shows the type of sensor  for the selected meter  Valid values are  Curved Tube and Straight Tube     Revised August 2015    Revised August 2015    Field  Manufacturer ID    Device Type    Current Pressure  Compensation Effect  on Flow    Current Pressure  Compensation Effect  on Density    Board Temperature    Input Voltage    Live Zero    Zero Standard    Deviation    Raw Tube Frequency    Left Pickoff Voltage    Left Pickoff    Amplitude    Right Pickoff Voltage    Right Pickoff  Amplitude    tab     Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Description    This read only field shows the manufacturer   s  ID for the selected meter     This read only field shows the specific type of  meter or transmitter connected to the module     This read only field shows the current  pressure compensation effect on flow of the  Coriolis meter  Default value is 0     This read only field shows the current  pressure compensation effect on density of  the Coriolis meter  Default value is 0     This read only field shows the board  temperature of the selecte
30. 000  The default is 0 0     Sets  in g cc  the high and low density values  for slug flow  The high density limit should be  greater than the low value  Valid values are  from 0 to 5 g cc  The default is 0 0     Sets the values for Pressure Correction Factor  for flow and density  Valid values are from  0 1  to 0 1  The default is 0 0     Sets the values for External Input Values for  temperature and pressure  Valid temperature  values range from    240   C to 450   C  Valid  pressure values range from     5 to 10000 BAR   The default for both is 0 0     Enables Load Optimization  Valid values are  Enabled and Disabled  Default is Disabled     17    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field Description   Correction of Mass Enables the module to calculate compensation  and Density for for the effect of high pressure on the  Pressure measurement accuracy of the Coriolis mass    flow and density    This calculation requires that you first provide  flow and density values for the Pressure  Correction Factors  and you must provide a  pressure value for the External Input Value   Valid values are Enabled and Disabled  The  default is Disabled     3  Click Apply to save any changes you have made to this screen     4  Proceed to Section 3 1 3 to configure the Diagnostics tab     18 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 3 Coriolis Setup and Val
31. 07     Field  Density Value    Volume Rate    Description    These read only fields show the density value at  the moment when the minimum and the  maximum drive gain values were recorded during  the current and the previous contract day   Configure units using the Units Configuration tab     These read only fields show the volume rate at  the moment when the minimum and the  maximum drive gain values occurred during the  current and the previous contract day  Configure  units using the Units Configuration tab     3  Proceed to Section 3 1 11 to configure the PVR tab     40    Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 11 Coriolis Setup and Values     PVR    This screen displays only if the connected Micro Motion Coriolis device  has the factory enabled production volume reconciliation  PVR  feature   Otherwise the message Feature not supported on this Micro Motion  meter displays     Use this screen to configure PVR parameters and view PVR related  flow rates and totals  To access this screen     1  Select the PVR tab  The PVR screen displays              T E ROCLINK 800    Coriolis Setup and Values   FB107  Sax        File Edit View ROC Configure Meter Utilities Tools Window Help            x  D Se Di E HU hn SA2ORR ef   2    Point Number   EE Meter Tag   ECP PVR 12         General  Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Confia   Values   Current Dump 
32. 12 Revised August 2015    Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 1 Coriolis Setup and Values     General Tab    Use this tab  which displays when you access the Coriolis Setup and  Values screen  to configure communications with one or more Coriolis  meters  configure and enable polling  and set communications  parameters        E  fo  ROCLINK 800    Coriolis Setup and Values   FB107     File Edit View ROC Configure Meter Utilities Tools Window Help      Doe Bi tr Whew 4 OR   ew    Meter Tag   ECP TBR 2    General   Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Config   Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR            Point Number      Micro Motion Coriolis Licensed Features    Communications  Modbus Address  313    2 Poll Mode    PVR   Production Volume Reconciliation  Poll Timeout  11 0 seconds S HR    SMY   Smart Meter Verification  isable    IV TBR  Liquid    Transient Bubble Remediation  I TMR  Gas    Transient Mist Remediation    Number of Retries   3  Actual Poll Period   0 95 seconds  Com Status  CGR    Meter Mode     Continuous Flow C Dump Cycle    Flow Direction Mode  17       Forward Only C Reverse Only    Bi Directional    Live Coriolis Values  Forward    Volume Flow Rate  253    00 US gal hour  Mass Flow Rate  247    ao kg hour  Sensor Temperature  251    7273302 F  Flowing Density  249    fo e9s0508 g cm    3  Drive Gain 
33. 2015    fields     Field  Mode    Status    Duration of Last    Drive Gain    TBR  Liquid  Control  Timeout    Timeout Period    Initial Action    Drive Gain Averaging    Apply to Flow    Timeout Action    Timeout Alarm Type    Apply to Density    Drive Gain Threshold    Description    Indicates whether TBR or TMR is enabled on  the selected meter     This read only field shows the TBR or TMR  status for the selected meter  if the option is  activated      This read only field shows the number of  seconds for the last recorded TBR or TMR  event     This read only field shows current drive gain  value  in percent  retrieved from the selected  meter     Sets  in seconds  the amount of time the  module holds the last measured value after  first detecting a bubble     Sets  in seconds  the amount of time the  module holds the last measured value after  first detecting a bubble  Valid values range  from 10 to 30 000 seconds  The default is 10  seconds     Indicates whether the module holds the last  measured density value from the time period  before transient bubbles were detected  The  Set TBR Active Status Only option allows  for the indication of transient bubbles  but  takes no action  Default is Hold Last Value     Sets the number of seconds during which the  module determines the average drive gain   Default is 1 Second     Determines if the TBR event affects the mass  flow rate and accumulation  Default is Yes     Sets the behavior of the selected meter when  the defined n
34. Cycle   Dump Cycle Min Max Data PYR  PYR Configuration  Ref Temperature  319     zoo 8  hbs  Dil Base Density  1959    08  g cm 3  Water Base Dens  1831   ho o g cm 3                PYR Flow Rates  Uncorrected Corrected  Water Cut  1555 57    0 0 0 0 z  Net Water Flw  1562 49    o0  00  Bbls d    Net Dil Flow  1553 47    foo 0 0 Bbls day  Mix Mass Rate  247    00 kg hour  Mix Volume Rate  253     oao  Bbls day  PYR Totals  Uncorrected Corrected  Net Water Flw  1667 63     1378 128 1322 181 Bbls  Net Oil Flow  1665 61    293 3511  269 2446 Bbl  Mix Mass  259    193686 1 kg       Print Save As Auto Scan Update Close Apply    ef    gt    DRENE 251 PM                Figure 16  Coriolis Setup and Values     PVR Tab    Note  Unit values on this screen are dynamic  and reflect the values  defined on the Units Config tab     2  Review the values in the following fields     Field Description  PVR Configuration  Ref Temperature Sets the temperature to which    corrected       flowrates and totals have been corrected   typically 60   F or 15   C     Revised August 2015 AD    Field  Oil Base Density    Water Base Dens    PVR Flow Rates    Water Cut    Net Water Flw    Net Oil Flow    Mix Mass Rate    Mix Volume Rate    PVR Totals  Net Water Flw    Net Oil Flow    Mix Mass    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Description    Sets the density of    dry    oil at base conditions   The module uses this value to calculate the  water 
35. Flow    Pressure Correction  Factor    External Input Values    Load Optimization    Description    Sets the Density Meter Factor value for the  selected Coriolis meter  Enter any decimal  value greater than zero  The system multiplies  this value by the live density reading to  produce the published density value     Sets the Flow Calibration Factor value for the  selected Coriolis meter  The default is 0     Sets the Temperature Calibration Factor value  for the selected Coriolis meter  The default is 0     Sets the Density Temperature Correction value  for the selected Coriolis meter  Valid values are  from  20 to 20  The default is 0 0     Sets the Density Flow Correction value for the  selected Coriolis meter  The default is 0 0     Sets the Flow Calibration Pressure value of the  selected Coriolis meter  Enter any decimal  value greater than zero  The default is 0 0     Sets the flow rate internal damping in seconds   Valid values are from 0 to 60 seconds  The  default is 0 0     Sets the values for Density Calibration Point 1   D1  and Density Calibration Point 2  D2   Valid  values are from 0 to 5 g cc  The default is 0 0     Sets the values for Tube Period D1  K1  and  Tube Period D2  K2  from the physical Coriolis  sensor plates  K1 is the tube period when the  sensor is filled with a fluid of Density D1  K2 is  the tube period when the sensor is filled with a  fluid of Density D1  Both of these values are in  units of microseconds  Valid values are from  1000 to 50
36. Part D301753X012  August 2015    Micro Motion   Coriolis Interface Module p  User Manual  for ROC800 Series and FloBoss  107 Controllers                          E    ROCLINK 800    Coriolis Setup and Values   FB107     File Edit View ROC Configure Meter Utilities Tools Window Help     ax  D S W D HAHM SORE RI   Point Number  fAs aA bd Meter Tag   ECP TBR 2  General   Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Config  Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR    Communications Micro Motion Coriolis Licensed Features  Modbus Address  313    2 Poll Mode    PYR   Production Volume Reconciliation  Poll Timeout   hoo    seconds   Enabled I SMY   Smart Meter Verification  i C Disabled Aa  4 ons  Naba of Maries  B    7 TBR  Liquid    Transient Bubble Remediation  I TMR  Gas    Transient Mist Remediation  Actual Poll Period   0 95 seconds taas i i i  Comm Status  CSc  Meter Mode     Continuous Flow    Dump Cycle  Flow Direction Mode  17     Forward Only C Reverse Only    Bi Directional  Live Coriolis Values  Forward  Volume Flow Rate  253   10 0 US gal hour  Mass Flow Rate  247   10 0 kg hour  Sensor Temperature  251    72 73302 F  Flowing Density  249    0 8980508     g cm 3  Drive Gain  291    6 491933    Print Save As Auto Scan  2  Update Close Apply       gt   EERE 251P  k a  s    EMERSON     Remote Automation Solutions    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Revis
37. TIVE  SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING    Houston TX USA 77072 BUT NOT LIMITED TO  LOSS OF PRODUCTION  LOSS OF PROFITS  LOSS OF REVENUE OR USE   T  1 281 879 2699   F  1 281 988 4445 AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL  FUEL AND POWER    www EmersonProcess com Remote AND CLAIMS OF THIRD PARTIES     Emerson Process Management Ltd  Remote Automation Solutions  UK   is a wholly owned  subsidiary of Emerson Electric Co  doing business as Remote Automation Solutions  a business  unit of Emerson Process Management  FloBoss  ROCLINK  ControlWave  Helicoid  and  OpentEnterprise are trademarks of Remote Automation Solutions  AMS  PlantWeb  and the  PlantWeb logo are marks owned by one of the companies in the Emerson Process Management  business unit of Emerson Electric Co  Emerson Process Management  Emerson and the Emerson  logo are trademarks and service marks of the Emerson Electric Co  All other marks are property  of their respective owners    The contents of this publication are presented for informational purposes only  While every  effort has been made to ensure informational accuracy  they are not to be construed as    Middle East Africa   Emerson Process Management  Remote Automation Solutions  Emerson FZE  P O  Box 17033  Jebel Ali Free Zone   South 2  Dubai U A E   T  971 48118100   F  971 4 8865465  www EmersonProcess com Remote    Asia Pacific  warranties or guarantees  express or implied  regarding the products or services described  Em
38. Verification   TBR TMR Meter Zero   Units Config   Values   Current Dump Cycle   Dump Cycle Min Max Data   PYR      Perform Meter Zero  Meter Zero Status  421   Complete  Previous Meter Zero Offset   0 0    New Meter Zero Offset  233    0 0150895    Start Zero  5                 Print Save As Auto Scan Update Close  RE 11 13 4M                   Figure 11  Coriolis Setup and Values     Meter Zero Tab    2  Review   and change as necessary   the values in the following  fields     Revised August 2015 27    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     28    Field    Meter Zero Status    Previous Meter Zero  Offset    New Meter Zero  Offset    Start Zero    Description    This read only field shows the current status  of the meter zero procedure  Valid values are  Complete  In Progress  Zeroing failed  Zero too  low  Zeroing failed  Zero too high  and Zeroing  failed  zero too noisy     This read only field shows the value of the  meter zero offset as determined by the  previous meter zero procedure     This read only field shows the value of the  meter zero offset as determined by the most  recent meter zero procedure     Click to begin the meter zero procedure     3  Proceed to Section 3 1 7 to configure the Units Configuration tab     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 7 Coriolis Setup and Values     Units Configuration    Use this screen to
39. ansmitter  3000 Transmitter    Number of Response Timeouts  1  0 4602637 Yy    0 897989 g cm 3  6 364013      0 4663078 Yy    0 4663078 Y    Left Pickoff Amplitude  379     Flowing Density  249      Drive Gain  291      Right Pickoff Voltage  289     Right Pickoff Amplitude  381       Reset Comm Stats    Meter Information  Meter Model Type     3019      Curved Tube     Straight Tube    c   Oj  C  Number of Error Responses  0 A  C  i   C    Manufacturer ID     121     m              Print Save As Auto Scan    2  Update   Close   Apply          gt   EE oor          Figure 8  Coriolis Setup and Values     Diagnostics Tab    2  Review the values in the following fields     Field  Meter Status  Sensor Failure    Description    This read only field shows the current status  of the selected meter based on the value in  the primary Coriolis status register  Valid  values are Yes and No     This read only field shows the meter   s  possibility of data loss  Valid values are Yes  and No     Data Loss Possible    This read only field shows the meter   s flow  direction  Valid values are Forward or  Reverse     Flow Direction    19    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field    Meter RTD Temp Out  of Range    Line RTD Temp Out  of Range    Density Outside  Standard Range    Temp  Outside  Standard Range    RAM Diagnostic  Failure    EEPROM Checksum  Failure    Drive Overrange    Density Outside of  Limits    Description    This 
40. ccumulated    Density    Drive Gain    Description    This read only field shows the current status  of a dump cycle  Valid values are Complete  and In Progress     This read only field shows the start time of the  current  in progress  dump cycle     This read only field shows the end time of  either the current  in progress  or the most  recently completed dump cycle     This read only field shows the volume  accumulated during either the current  in  progress  or the most recently completed dump  cycle  Configure units using the Units  Configuration tab     These read only fields show the minimum and  maximum density during either the current  in  progress  or the most recently completed dump  cycle  Configure units using the Units  Configuration tab     These read only fields show  in percent  the  minimum and maximum drive gain during  either the current  in progress  or the most  recently completed dump cycle     3  Click Apply to save any changes you have made to this screen     4  Proceed to Section 3 1 10 to configure the Dump Cycle Min Max  Data tab     Revised August 2015    37    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 10 Coriolis Setup and Values     Dump Cycle Min Max Data    Note  This screen is available only if you select Dump Cycle as the  Meter Mode on the General tab     Use this screen to view density and drive gain minimum and maximum  values  cycle start and end times  and volume rates for the s
41. contract day  Mass units  are determined based on the  configuration of the meter    The mass accumulated in the  previous month  Mass Total units  are determined based on the  configuration of the meter   Amount of reverse mass  accumulated by the module  This  accumulator rolls over at  1 000 000 0    75    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System  or User  Update    76    Parm       181    182    183    184    185    186    187    188    189    190    191    Name    Volume Flow Rate  Reverse    Mass Flow Rate  Reverse    Mass Den Correction  for Pressure    Water Cut Uncorrected    Water Cut Corrected    Net Water Flow    Uncorrected    Net Water Flow  Corrected    Net Oil Flow  Uncorrected    Net Oil Flow Corrected  Net Water Total  Uncorrected    Net Water Total  Corrected    Access    R O    R O    R W    R W    R W    R W    R W    R W    R W    R W    R W    System    System    User    System    System    System    System    System    System    System    System    Data  Type  FLOAT    FLOAT    UNIT8    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    Length    Range    4 Any positive  floating point  number    4 Any positive  floating point  number    1 0 1    4 Any positive  floating point   number  4 Any positive  floating point   number  4 Any positive  floating point   number  4 Any positive  floating point   number  4 Any pos
42. cut and determine the percentage of oil  versus water in the stream  Value is obtained  from a petroleum analysis laboratory or an  external calculation routine     Sets the density of produced water at base  conditions  The module uses this value to  calculate the water cut and determine the  percentage of oil versus water in the stream   Value is obtained from a petroleum analysis  laboratory or an external calculation routine     These read only fields show the calculated  water cut  percentage   where 100  is pure  produced water and 0  is pure oil     These read only fields show the volume flow  rate of the water     These read only fields show the mass flow rate  of the liquid mixture  unremediated by PVR     This read only field shows the mass flow rate of  the liquid mixture  remediated for PVR     This read only field shows the volume flow rate  of the mixture  remediated by PVR     These read only fields show the net volume  accumulation of the water  The uncorrected   value is at line  flowing  conditions  and the   corrected value is at reference temperature   conditions     These read only fields show the net volume total  accumulation of the oil  The uncorrected value is  at line  flowing  conditions  and the corrected  value is at reference temperature conditions     This read only field shows the mass  accumulated total of the mixture  unremediated  for PVR     3  Click Close to return to the ROCLINK 800 screen  Proceed to    Section 3 2 to save your configura
43. d meter  Default  value is 0     This read only field shows the input voltage  of the selected meter  Default value is 0     This read only field shows the live zero in  mass flow of the selected meter  Default value  is 0     This read only field shows the zero standard  deviation value of the selected meter  Default  value is 0     This read only field shows the raw tube  frequency in Hz of the selected meter  Default  value is 0     This read only field shows the left pickoff  voltage of the selected meter  Default value is  0     This read only field shows the left pickoff  amplitude in volts of the selected meter   Default value is 0     This read only field shows the right pickoff  voltage of the selected meter  Default value is  0     This read only field shows the right pickoff  amplitude of the selected meter  Default value  is 0     3  Proceed to Section 3 1 4 to configure the Smart Meter Verification    21    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 4 Coriolis Setup and Values     Smart Meter Verification    Use this screen to view the Smart Meter Verification status for the  selected Coriolis meter  This screen displays only if Smart Meter  Verification is available for that sensor and only if that sensor is  connected to a Coriolis meter using the 800 enhanced core processor     Note  The message Feature not supported on this Micro Motion meter  displays if this meter does not support Smart Meter Verificat
44. ding   Bit 11   Temperature Sensor Out   of Range   Bit 12   Input Over Range   Bit 13   Frequency Output  Saturated   Bit 14   Transmitter Not  Characterized   Bit 15   Real Time Interrupt  Failure    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    System PE      Parm Data   Description of functionality and    Name Access Uh pu Type Length Range Default Version meaning of values  138 Status Word 3 R O System UINT16 2 0 65535 0 1 00 Status Word 3     Bit 0   Burst Mode Enabled   Bit 1   Power Reset Occurred   Bit 2   Transmitter  Initializing Warming Up   Bit 3   Sensor Xmtr  Communication Failure   Bit 4   Paper Out   Bit 5   Event  2 Triggered   Bit 6   Event  1 Triggered   Bit 7   Sensor Xmtr  Communication Failure   Bit 8   Calibration Failure   Bit 9   Excess Calibration  Correction  Auto Zero too  Low   Bit 10   Excess Calibration  Correct  Autozero too High   Bit 11   Process too Noisy to  Perform Auto Zero   Bit 12   Transmitter Failed   Bit 13   Data Loss Possible   Bit 14   Calibration In Progress   Bit 15   Slug flow    Revised August 2015 69    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System  ol Name Access or User We  Update  139 Status Word 4 R O System UINT16 2 0 65535 0 1 00 Status Word 4   Bit 0   API VCF  Temperature  Outsid
45. e    State at Abort    Start Meter  Verification    Description    Sets the stiffness setpoint for the Smart Meter  verification  Valid values range from 0 0025 to  0 4     Sets the value the meter uses when initiating the  Smart Meter verification process  Default is Start  with Output Fixed     This read only field shows the current state of  the verification  Valid values are Stopped and  Running     This read only field shows the completion  percentage of the current verification procedure     This read only field shows the inlet stiffness  value for the verification  Valid values are 0  In  Limits  and 1  Out of Limits      This read only field shows the outlet stiffness  value for the verification  Valid values are O  In  Limits  and 1  Out of Limits      This read only field shows the Abort  Error   Code for the previous verification  Valid values  are     0   No Error   1   User Initiated Abort   2   Frequency Drift   3   Unstable flow   4  No Air   5   No Water Reference   6   Missing Configuration Data   7   General drive error   8   Delta T erratic   9   Delta T too high   10   State running   11   State completed   12   Meter verification data error   13   Unit has not been calibrated on air  14   Unit has not been calibrated on water  15   Meter verification configuration items are  not correct    This read only field shows the state of the  verification when the last abort occurred  Valid  values are 16  SMV Completed  and 0 15  SMV  Aborted before completion   
46. e  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These fields display only if you select  Continuous as the Meter Mode and  either Reverse Only or Bi Directional  as the Flow Direction Mode on the  General tab     Reverse Total Mass These read only fields show the mass  accumulated in the current contract day   Today   in the previous contract day   Yesterday   and in the current month   Monthly   The value in the Accumulated field  provides a running total for all dump cycles  is  updated after the completion of a dump cycle  and during trickle flow  and rolls over at  1 000 000 units  Configure units using the  Units Configuration tab     Once the contract day is over  the value in the  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These fields display only if you select  Dump Cycle as the Meter Mode and  either Reverse Only or Bi Directional  as the Flow Direction Mode on the  General tab     Totals  Dump Cycle selected as Meter Mode on General tab     Number of Dump These read only fields show the number of   Cycles dump cycles that have occurred in the current  contract day  Today   in the previous contract  day  Yesterday   and for the current month   Monthly      Note  These fields display only if you select  Dump Cycle as the Meter Mode on the  General tab     Revised August 2015 33    Micro M
47. e Standard  Bit 1   API VCF  Line Density  Outside Standard Range  Bit 2   Line RTD Temperature Out   of Range  Bit 3   Case Meter RTD  Temperature Out of Range  Bit 4   Flow Direction  0    Forward 1   Reverse   Bit 5   Factory Configuration Data  is Invalid  Bit 6   Enhanced Density  Unable  to fit curve data  Bit 7   Last Measured Value  Override Active  Bit 8   Enhanced Density  Extrapolation Alarm  Bit 9   Cal Factors Unentered  Bit 10   1000 2000 3000 EEPROM  Checksum Error  Bit 11   1000 2000 3000 RAM  Test Error  Bit 12   Unrecognized Unenterd  Sensor Type  Bit 13   Core Configuration  Database Corrupt  Bit 14   Core Power Down Totals  Corrupt  Bit 15   Core Program Corrupt  140 SMV Output State R W Userand  UINT16 2 0 1 0 1 00 Smart Meter Verification Output  System State during procedure   0   Last Value  1   Fault Value  141 TBR Timeout R W User and UNIT16 2 0 30 000 0 1 00 For TBR  the amount of time  in   seconds  System seconds that the last measured  value will be held after a bubble is  first detected   TMR Pre Mist Average R W User and UNIT16 2 0 30 000 0 1 00 For TMR  the amount of time  in  Period  seconds  System seconds  for the pre mist period     Description of functionality and    Length Range Default Version meaning of values    70 Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       142 TBR LMV Sample  Position    Name
48. eaeeeeeeeseeeeeseaeeeteaeeteaes 16   3 1 3 Coriolis Setup and Values     Diagnostics Tab      0    cccesceeeeeeceeeeeseeeeeeeseeeeeeseaeeseneeesaes 19   3 1 4 Coriolis Setup and Values     Smart Meter Verification                ccccessccesssseeeeesssteeesseeeees 22   3 1 5 Coriolis Setup and Values     TBR TMR    0      ccceecceeeeeeceeneeeeeeeeceaeeeeaaeeeeaeeseeaeeesaeeneaeeeeaes 24   3 1 6 Coriolis Setup and Values     Meter Zer0        eseceeccceceeeeeseeceeeeeceeeeeaeeeeaeeseeeeeseaeeseaeeeeaes 27   3 1 7 Coriolis Setup and Values     Units Configuration             ccccccceeeceeeeeeceeeeeseeeeeeeaeeeeneeesaees 29   3 1 8 Coriolis Setup and Values     Values        0  eceeeececeeeeeeeeeeeseeseeeeeaaeeesaaeeseaeeesaaeeesaeeeeees 31   3 1 9 Coriolis Setup and Values     Current DUMP CyCle            ccceeeeeeeseeeeeeneeseeeeeteaeeetaeenenes 36   3 1 10 Coriolis Setup and Values     Dump Cycle Min Max Data              cccceeeceeeeeeeeseeeeeseeteaes 38   3 1 11 Coriolis Setup and Values     PVR        cccceeccecesseeeeeeeeeeeeeeeeeeeeeeeceaeeesaaeeseaeeseeeeesaeeneneeeeaes 41   3 2 Saving the  Configuratio Mennien oiiire anne aaia ia a a aaiae 43  Chapter 4     Reference Materials 45  4 1 Point Type 65 244  Micro Motion Coriolis Interface MOdUIe               c ccceeeceeeeeeeeeeeeeteeeeeaeeeeneeeee 46  Revised August 2015 ili    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107      This page is intentionally left blank      iv Revi
49. elected  Coriolis meter  To access this screen     1  Select the Dump Cycle Min Max Data tab  The Dump Cycle  Min Max Data screen displays                   ROCLINK 800    Coriolis Setup and Values   Remote Oprtns Cntrir  Erima    File Edit View ROC Configure GasMeters Liquid Meters Utilities Tools Window Help     5    xX  Dw wd Gt k   M ME SZORRI KERI    Point Number    i Meter i x  Meter Tag   Meter      General  Calibration   Diagnostics   Smart Meter Verification   TBR TMR   Meter Zero   Units Contig  Values   Current Dump Cych       Density Min Max Occurrences       Today s Minimum Today s Maximum Yesterday s Minimum Yesterday s Maximum  Cycle Start Time   00 00 00 00 00 00 00 00 00 00 00 00  Cycle End Time  00 00 00 00 00 00 00 00 00 00 00 00  Time of Occurrence   00 00 00 00 00 00 00 00 00 00 00 00  Min Max Density Value   0 0  o o  o o  o o a em 3  Average Density   00 joo t     S joo 8    o0 gma  Drive Gain Value   joo t        bo bo t    an    VolumeRate   0 0 joo t       foo 8     o0  Bbls day    Drive Gain Min Max Occurrences    Today s Minimum Today s Maximum Yesterday s Minimum Yesterday s Maximum          Cycle Start Time   00 00 00 00 00 00 00 00 00 00 00 00  Cycle End Time  00 00 00 00 00 00 00 00 00 00 00 00  Time of Occurrence   00 00 00 00 00 00 00 00 00 00 00 00  Min Max Drive Gain Value   0 0  0 0  0 0  o o    Average Drive Gain   bo bo t       bo 8t    bo         Density Value   0 0 0 0 0 0 foo g om   3  Volume Rate   oo oo bo t        bo Bbls day      
50. ent     The volume rate recorded when  the maximum density value for the  previous contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the minimum density value  for the previous contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The end time of the dump cycle in  which the minimum density value  for the previous contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the minimum  density value for the previous  contract day was recorded   Byte 3   Unused   Byte 2   Hours   Byte 1   Minutes   Byte 0   Seconds    57    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    58    Parm       60    61    62    63    64    65    Name    Yesterday   s Minimum  Density    Drive Gain at  Yesterday   s Minimum  Density    Volume Rate at  Yesterday   s Minimum  Density    Today   s Maximum  Drive Gain Cycle Start  Time    Today   s Maximum  Drive Gain Cycle End  Time    Today   s Maximum  Drive Gain Time of  Occurrence    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    FL    FL    UINT32    UINT32    UINT32    Length    Range  Any positive    floating point  number    Any positive  fl
51. erson Process Management herein or their use or applicability  Remote Automation Solutions reserves the right to modify  Remote Automation Solutions or improve the designs or specifications of such products at any time without notice  All sales  1 Pandan Crescent are governed by Remote Automation Solutions    terms and conditions which are available upon  Singapore 128461 request  Remote Automation Solutions does not assume responsibility for the selection  use or  T  65 6777 8211  F  65 6777 0947 maintenance of any product  Responsibility for proper selection  use and maintenance of any  www EmersonProcess com Remote Remote Automation Solutions product remains solely with the purchaser and end user          Remote Automation Solutions EMERSON     
52. essure Units  Valid values are   0   Unknown   1   Inches water   68 degrees    Fahrenheit   2   Inches mercury   0 degrees  Celsius   3   Feet water   68 degrees  Fahrenheit    4   Millimeters water   68  degrees Fahrenheit    5   Millimeters mercury   0  degrees Celsius    6   Pounds square inch   7   Bar   8   Millibar   9   Grams square centimeter   10   Kilograms square centimeter   11   Pascals   12   Kilopascals   13   Torr   0 degrees Celsius   14   Atmospheres   145   Inches water   60 degrees  Fahrenheit   237   Megapascals   238   Inches water   4 degrees  Celsius    239   Millimeters water   4  degrees Celsius  Flow Calibration Factor  FCF     Temperature Calibration Factor  Amount of volume accumulated by    the module  This accumulator rolls  over at 1 000 000 0    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       171 Mass Accumulated    Name    172 Flow Direction  Calculated    173 Rev Volume Today    174 Rev Volume Yesterday    175 Rev Volume Monthly    176 Rev Volume    Accumulated    177 Rev Mass Today    178 Rev Mass Yesterday    179 Rev Mass Monthly    180 Rev Mass  Accumulated    Revised August 2015    Access    R W    R W    R W    R W    R W    R W    R W    R W    R W    R W    System  or User  Update  System    System    System    System    System    System    System    System    System    System    Data  Type  FLOAT
53. feet hour  131   Cubic meters minute  132   Barrels second  133   Barrels minute  134   Barrels hour  135   Barrels day  136   U S  gallons hour  137   Imperial gallons second  138   Liters hour  253   Special  For TBR  the current mass flow  rate retrieved from the meter  Mass  rate units are determined based on  the configuration of the meter     For TMR  the unremeditated mass  flow rate retrieved from the meter   Mass rate units are determined  based on the configuration of the  meter     49    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System  ge Name Access or User   AR  Update yp  12 Mass Flow Rate Units R W System UINT16 2 0  70 253 0 1 00 Mass Flow Rate Units     Description of functionality and    Length Range Default Version meaning of values    0   Unknown   70   Grams second   71   Grams minute   72   Grams hour   73   Kilograms second   74   Kilograms minute   75   Kilograms hour   76   Kilograms day   77   Metric tons minute   78   Metric tons hour   79   Metric tons day   80   Pounds second   81   Pounds minute   82   Pounds hour   83   Pounds day   84   Short tons  2000  pounds  minute   85   Short tons  2000  pounds  hour   86   Short tons  2000  pounds  day   87   Long tons  2240  pounds  hour   88   Long tons  2240  pounds  day  253   Special   13 Live Sensor R O System FL 4 Any positive 0 1 00 Current Temperature value  Temperature floating point re
54. hly Total Number  of Dump Cycle    35 Monthly Total  Accumulated Volume    Revised August 2015    Access    R O    R W    R O    R O    R W    R W    R O    R W    System  or User  Update  System    System    System    System    System    System    System    System    Data  Type  UINT16    FL    UINT16    UINT16    FL    FL    UINT32    FL    Length    2    Range    0  40 253    Any positive  floating point  number    0  60 253    0 65536    Any positive  floating point  number    Any positive  floating point  number    0 4294967295  Any positive    floating point  number    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Volume Total Units     0   Unknown  40   U S  gallons  41   Liters    42   Imperial gallons   43   Cubic Meters   46   Barrels  42 U S  gallons   112   Cubic feet  253   Special  The mass accumulated in the  current contract day  Mass Total  units are determined based on the  configuration of the meter     Mass Total Units     0   Unknown  60   Grams  61   Kilograms  62   Metric tons  63   Pounds    64   Short tons  2000 pounds   65   Long tons  2240 pounds   253   Special  The number of dump cycles that  have occurred in the previous  contract day     The volume accumulated in the  previous contract day  Volume  units are determined based on the  configuration of the meter     The mass accumulated in the  previous contract day  Mass units  are determined based 
55. imeout   5   Invalid CRC   6   Invalid Response Format  7   Slot Register Configuration  Failed   8   Slow Poll Mode   9   Reset Totals Failed   10   Incompatible target device  firmware version    Note     Slow poll mode    occurs  when the module   s poll request  fails  all retries are exhausted  and  the device is not responding  which  might occur if the connecting wire  has been cut   In this case  the  device automatically slows polling   shifting from a once per second  poll sequence to a once every 10   seconds poll sequence  Once the  communication problem is  resolved  normal polling resumes  within 10 seconds     The current status of the Coriolis  meter based on the primary  Coriolis status register     0   No Failure  1   Sensor Failure    7 Meter Status R O System UINT8 1 0 1 0 1 00    Revised August 2015 47    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm    Name  8 Volume Low Flow  Cutoff  9 Live Volume Flow  Rate    Live Volume Flow  Rate    48    Access    R W    R O    R O    System   or User   Update  User    System    System    Data  Type  FL    FL    FL    Length Range    4 Any floating point  number    4 Any positive  floating point  number    4 Any positive  floating point  number    Default Version  0 1 00  0 1 00  0 1 00    Description of functionality and  meaning of values    The volume flow rate limit at which  the flow rate should be c
56. ion     To access this screen     1  Select the Smart Meter Verification tab  The Smart Meter  Verification screen displays                    F  E   ROCLINK 800    Coriolis Setup and Values   FB107  arim    File Edit View ROC Configure Meter Utilities Tools Window Help  o x  De Gt   Wiha MSTORE B   Point Number   3  ECP PYR12 v Meter Tag   ECP PVR 12  General  Calibration   Diagnostics i BR TMR   Meter Zero   Units Confia   Values   Current Dump Cycle   Dump Cycle Min Max Data   PYR    Configuration Start Action  3000   Output State  3093  Start with Output Fixed    Last Value  C Fault Value Start with Continuous Values    Stiffness Setpoint  3147    0 04    Status    Current Procedure  Current State  3001   Stopped    Percent Complete  3020     0   Stiffness Abort  Inlet  3004   Pass Abort Code  3002   0    Outlet  3005   Pass State at Abort  3003   0          Print Save As Auto Scan    2  Update   Close   Apply         4              gt    RENNE 3 28 Pu          Figure 9  Coriolis Setup and Values     Smart Meter Verification Tab    2  Review   and change as necessary   the values in the following    fields   Field Description  Output State Sets the output state of the Smart Meter during    the verification procedure  Default is Last Value     22 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field    Stiffness Setpoint    Start Action    Current State    Percent Complete    Inlet    Outlet    Abort Cod
57. ion  tab     These read only fields show  in percent  the  drive gain value at the moment when the  minimum and the maximum density values were  recorded during the current and the previous  contract day     These read only fields show the volume rate at  the moment when the minimum and the  maximum density values were recorded during  the current and the previous contract day  Units  are configured in the Units Configuration tab     Drive Gain Min Max Occurrences    Cycle Start Time    Cycle End Time    Time of Occurrence    Min Max Drive Gain    Value    Average Drive Gain    These read only fields show the start time of the  dump cycle in which the minimum and the  maximum drive gain values were recorded during  the current and the previous contract day     These read only fields show the end time of the  dump cycle in which the minimum and the  maximum drive gain values were recorded during  the current and the previous contract day     These read only fields show the time at which  the minimum and the maximum drive gain values  were recorded during the current and the  previous contract day     These read only fields show  in percent  the   minimum and the maximum drive gain values  recorded during the current and the previous   contract day     These read only fields show  in percent  the  average drive gain values recorded during the  current and the previous contract day     39    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    1
58. ion Tracking Sheet  August 2015    This manual may be revised periodically to incorporate new or updated information  The revision date of each  page appears at the bottom of the page opposite the page number  A change in revision date to any page also  changes the date of the manual that appears on the front cover  Listed below is the revision date of each page  if  applicable      Page Revision  All pages Aug 2015  All pages May 2015    Initial release Feb 2014    ii Revised August 2015             Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107   Chapter 1     Introduction 1  1 1 Scope and Organization            ceccccecccccececeeneeeeeeeeceaeeeeaaesseneeceaaeeeeaaesgeneeceaeeesaaesseaeeseeeeesaeeeeaaeeseneesaas 1   1 2 Product OVE W caeai ted uli Aled eee AL aaa ae i tel ar a 2   1 3 Program Require ment    s c  setvete sects fet aurea ca edges eNA Naa a eee abode een 3  Chapter 2     Installation 5  2 1 Installing the  Module  rases aue cent iatueds sauces ag dee dy sald eg eke Gildas dy ald eg teed alg heed abet 5   2 2 Wiring the  Module  cis   Acie r Minne thie atest Sickie ed eth Se dap eta 5  Chapter 3     Configuration 9  3 1 Coriolis Setup and Values Sree Mariin eia tamaaa aiena Ear na eaaa aa er aa A a rE AA ar a naat 10   3 1 1 Coriolis Setup and Values     General Tab  0          cccccseseceeeeeceeeeeeeaeeeeaeeeseeeesaeeeeeeeneees 13   3 1 2 Coriolis Setup and Values     Calibration Tab            ccccccceeceseceeeeee
59. itive  floating point   number  4 Any positive  floating point   number  4 Any positive  floating point   number  4 Any positive  floating point   number    Default    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    Version    1 00    1 00    1 00    Description of functionality and  meaning of values    Current Reverse Volume Flow  Rate retrieved from the meter   Volume Rate units are determined  based on the configuration of the  meter    Current Reverse Mass Flow Rate  retrieved from the meter  Mass  Rate units are determined based  on the configuration of the meter   Enables disables the meter  correction for the effect of pressure  on the mass flow and density  This  feature requires the external  pressure  parameter 161  to be  populated  as well as the pressure  correction factors  parameters 162    and 163    0   Disabled  1   Enabled    The value of the calculated water  cut of the oil water mixture at line   flowing  conditions    The value of the calculated water  cut of the oil water mixture at  reference  base  conditions    The volume flowrate of the water at  line  flowing  conditions     The volume flowrate of the water at  reference  base  conditions     The volume flowrate of the oil at  line  flowing  conditions     The volume flowrate of the oil at  reference  base  conditions     The volume accumulation of the  water at line  flowing  conditions     The volume accumulation of the  water at reference  base   conditions     Revised Aug
60. l    Previous Mass Total    Access    R W    R W    R O    R O    R O    R O    R O    R O    R O    R O    System  or User  Update  User and  System    User and  System    System    System    System    System    System    System    System    System    Data  Type  UINT8    UINT8    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    Range    0 1    0 1    Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number  Any positive  floating point  number    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Reset all communication statistics   The value of this parameter returns  to 0 once the reset process is  complete     0   Disabled  1   Reset Stats     Reset all totals  Current  Today   Yesterday  and Monthly  that are  stored in the module  The  Minimum and Maximum values are  also reset     0   Disabled   1   Reset Totals   The total volume that the meter  has recorded while not in a dump  cycle for the current contract day  The total mass that the meter has  recorded while not in a dump cycle  for the current contract day    The total volume that the meter  has recorded while not in a dump  cycle for the previous contract day  The total 
61. le keeps  track of the total volume and mass accumulated during a dump  cycle  and updates the volume and mass totals once the dump cycle  has ended  The maximum and minimum density and drive gain  values that occurred during the dump cycle are also determined     The module uses the contract hour you define using ROCLINK 800 to  determine when a new contract day has begun  The module stores the  maximum and minimum density and drive gain values  the number of  dump cycles  and the volume and mass accumulators for the current and  previous contract days  When a new contract day is reached  the module  saves the values for the current contract day as the previous day values   and then resets the current day values  The module also records monthly  totals for volume  mass  and the number of dump cycles  The module  zeroes totals at the beginning of a new month  which occurs on the  contract hour of the first day of a new month     Note  The totals shown on the Values tab are based on the specified  contract hour  These totals are independent from the Force End  of Day selection  ROC  gt  Information   and are not updated  when you perform a Force End of Day     The continuous mode is designed to measure gas or liquid flow when  the flow is not coming from a separator monitoring system  In this mode  the module continuously requests data from the meters  retrieving and  saving values for Total Volume for Today  Yesterday Total Volume   Yesterday s  Monthly and the accumulated va
62. low   1   Density OOL  Bit 6  Timeout   0   Disabled   1   Enabled  Smart Meter Verification Stiffness  Setpoint  For TBR  the Drive Gain  percentage above which TBR  triggers   For TMR  the Drive Gain  percentage above which TMR  triggers   Flow rate internal damping   seconds   Mass Flow Cutoff    Density Calibration Point 1  D1     71    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    72    Parm       149    150    151    152    153    154    155    156    157    158    159  160    161    162    163    Name    Density Calibration  Point 2  D2    Tube Period   D1   K1    Tube Period   D2   K2    Density Temperature  Correction  DT   Density Flow  Correction  FD     Slug Flow High  Density Limit  g cc   Slug Flow Low Density  Limit  g cc    Sensor High Mass  Flow Limit    Sensor High Volume  Flow Limit    Device Type    Manufacturer ID  External temperature  input value   External pressure  input value   Pressure correction  factor for flow  Pressure correction  factor for density    Access    R W    R W    R W    R W    R W    R W    R W    R W    R W    R O    R O  R W    R W  R W    R W    System  or User  Update  User and  System  User and  System  User and  System  User and  System  User and  System    User and  System  User and  System  System    System    System    System  User and  System  User and  System  User and  System  User and  System    Data  Type  FLOAT  
63. low rate  When used with  gas meter runs on the ROC800 ROC800L or  FB107  use this value as the flow rate input     This read only field shows the mixture   s  unremediated accumulated mass total     This read only field shows the mixture   s  remediated accumulated mass total  When  used with gas meter runs on the  ROC800 ROC800L or FB107  use this value  as the accumulator input     3  Click Apply to save any changes you have made to this screen     4  Proceed to Section 3 1 5 to configure the Meter Zero tab     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 6 Coriolis Setup and Values     Meter Zero       Note  Before you activate the zeroing process  shut off the meter   s  flow and block the meter with valves to isolate any pulsations  from the line  Refer to the appropriate Micro Motion calibration  procedures        Zeroing the meter establishes a baseline for process measurement  by    analyzing the sensor   s output when there is no flow through the sensor  tubes     Use this screen to perform the meter zero process for the selected  Coriolis meter  To access this screen     1  Select the Meter Zero tab  The Meter Zero screen displays           ROCLINK 800    Coriolis Setup and Values   FB107  balba    File Edit View ROC Configure Meter Utilities Tools Window Help   ea Ot Yow iS 4 OM Be  Point Number    2 ECPTMR1  gt   Meter Tag  JECPTMR 1      General  Calibration   Diagnostics   Smart Meter 
64. lue since the last reset  The  module retrieves and saves mass values for the same periods     Note  In case of a communications failure  the module is set to    hold  last value        1 3 Program Requirements    Revised August 2015    The Micro Motion Coriolis Interface module is compatible with version  1 70  or greater  of the FB107 firmware  with version 3 61  or greater   of the ROC800 firmware  with version 1 41  or greater  of the  ROC800L firmware  and with version 2 40  or greater  of the  ROCLINK 800 configuration software     Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     If used in conjunction with user programs  the Micro Motion Coriolis  Interface module works with version 1 02  or greater  of the Linear  Meter Flow Calculation program     The Coriolis Interface module supports the following firmware versions  of these core processors and transmitters                          Device Type Firmware Version  700 Core Processors 3 2 or greater  800 Enhanced Core Processor 3 9 or greater  1500 Transmitter 6 6 or greater  1700 Transmitter 6 6 or greater  2500 Transmitter 6 6 or greater  2700 Transmitter 6 6 or greater  3000 Series Transmitter 8 2 or greater          Note  The comm settings for the Interface module are fixed at a baud  rate of 19 200  no parity  8 data bits  and 1 stop bit  You cannot  change these values  the meter   s core processor detects this  protocol and matches them automatically  However  if you
65. mass that the meter has  recorded while not in a dump cycle  for the previous contract day   Volume total based on the volume  total read from the double  precision accumulator in the  Coriolis meter    Previous volume total based on the  volume total read from the double  precision accumulator in the  Coriolis meter during the previous  second    Mass total based on the mass total  read from the double precision  accumulator in the Coriolis meter   Previous mass total based on the  mass total read from the double  precision accumulator in the  Coriolis meter during the previous  second     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       111    112    113    114    115    116    117    118    119    120    Name    Licensed Features    SMV Start    Flow Type    TBR Enable Disable    Current Pressure  Compensation Effect  On Flow    Current Pressure  Compensation Effect  On Density    Duration of Last TBR    Zero Standard  Deviation   Left pickoff voltage   volts    Right pickoff voltage   volts     Revised August 2015    Access    R O    R W    R W    R W    R O    R O    R O    R O    R O    R O    System  or User   A  Update YP    System UINT8  User and UINT8  System   User and UINT8  System   System UINT8  System FLOAT  System FLOAT  System FLOAT  System FLOAT  System FLOAT  System FLOAT    Length    Range    0 2    0 1    Oor1    Any po
66. mmunications port on the module  using between 16 and 24 AWG wiring  Figure I and Figure 2 show  example wiring between the module and several meters     Note  Coriolis meters must be externally powered     Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107                                      W  gt                             24V  EXTERNAL  POWER                      DOODO                               DOC0947B                                                                                        24V  EXTERNAL  POWER             A  B                                                                         24V  EXTERNAL  POWER       RDOUS AREA                                                                          L   HAZARDOUS APPLICATION          24V  EXTERNAL  POWER          Figure 1  Module Wiring       NON HAZARDOUS APPLICATION       Micro Motion 700 800 Coriolis Meter with Internal Core Processor    Micro Motion MVD Direct Connect    Safety Barrier    Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Revised August 2015       A       Sh      O  O      O    Figure 2  Module Wiring    Micro Motion 700 800 Coriolis Meter with Internal Core Processor   Micro Motion 1700  single variable   2700  multi variable   or 3000 Series  transmitter suited for use in a hazardous area   Cc Micro Motion 1500  single variable   2500  multi variable   or 3000 Series  transmitter sui
67. n Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System    sol Name Access or User   AA  Update yp  164 Flow Calibration R W User and FLOAT  Pressure System  165 LD Optimization R W User and UINT16  System  166 Flow Direction Setup R W User and UINT8  System    Revised August 2015    Length    Range    Any positive  floating point  number  0 1    0 5    Default    0 0    Version    1 00    1 00    1 00    Description of functionality and  meaning of values    Flow calibration pressure    LD Optimization for liquid  hydrocarbons  Should not be  enabled for gas measurement   0   Disabled   1   Enabled   The flow direction configured for  the meter     0   Forward Only   1   Reverse Only   2   Bi Directional   3   Absolute Value   4   Negate Forward Only  5   Negate Bi Directional    73    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    System  PAN Name Access or User   ata Length Range  Update ype  167 Pressure Units R W User and UINT16 1 0 239  System  168 Flow Calibration R W User and AC 20 ASCII  Factor  FCF  System  169 Temperature R W User and AC 20 ASCII  Calibration Factor System  170 Volume Accumulated R O System FLOAT 4 Any positive  floating point  number  74    Default    0    Version    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values   Pr
68. nd Smart Meter  Verification  provided these functions are activated on the Coriolis  meter   s core processor      The module operates in either continuous mode  during which flow  never ceases  or dump cycle mode  during which  should flow drop  below a minimum setpoint  the module stops accumulating flow  counts  cycles  and stores cycle specific data      Using Modbus  the module continuously requests data from the meters   When it receives new data  the module compares the volume flow rate  from the meter to the user defined volume low flow cutoff value and  performs the following actions       Ifthe value of the volume flow rate register is zero  the  parameters in the module   s point type corresponding to the values    2 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     received from the meter are updated  and no further processing of  the data is performed       If the value is greater than zero but less than the volume low  flow cutoff value  the module considers the volume and mass  accumulated to be trickle flow  The accumulated volume and mass  values are added to both the daily totals parameters and the separate  trickle flow totals       Ifthe value of volume flow rate is greater than the module   s low  flow cutoff value  the module considers the values received during  the period at which the volume flow rate remains above the volume  low flow cutoff value to be part of a dump cycle  The modu
69. nds    The end time of the dump cycle in  which the minimum drive gain  value for the current contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    Revised August 2015    59    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    60    Parm       72    73    74    75    76    77    Name    Today   s Minimum  Drive Gain Time of  Occurrence    Today   s Minimum  Drive Gain    Density at Today   s  Minimum Drive Gain    Volume Rate at  Today   s Minimum  Drive Gain    Yesterday   s Maximum  Drive Gain Cycle Start  Time    Yesterday   s Maximum  Drive Gain Cycle End  Time    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  UINT32    FL    FL    FL    UINT32    UINT32    Length    Range    0 235959    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    0 235959    0 235959    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The time at which the minimum  drive gain value for the current  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The minimum drive gain value  recorded during the current  contract day  Drive gain units are  percent    
70. ned by the associated  density unit selection  parameter  16      Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107      This page is intentionally left blank      Revised August 2015 79    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     For Customer Service and Technical Support    Dial  1 800 537 9313       Headquarters   Emerson Process Management  Remote Automation Solutions  6005 Rogerdale Road  Houston  TX 77072 U S A   T  1 281 879 2699   F 1 281 988 4445  www EmersonProcess com Remote    Europe   Emerson Process Management  Remote Automation Solutions  Unit 8  Waterfront Business Park    Dudley Road  Brierley Hill    2014 2015 Remote Automation Solutions  a business unit of Emerson Process   Dudley UK DY5 1LX Management  All rights reserved    T  44 1384 487200   F  44 1384 487258 Remote Automation Solutions  a business unit of Emerson Process Management  shall not be   www EmersonProcess com Remote liable for technical or editorial errors in this manual or omissions from this manual  REMOTE  North American Latin America  AUTOMATION SOLUTIONS MAKES NO WARRANTIES  EXPRESSED OR IMPLIED  INCLUDING THE   Emerson Process Management IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH   Remote Automation Solutions RESPECT TO THIS MANUAL AND  IN NO EVENT SHALL REMOTE AUTOMATION SOLUTIONS BE   6005 Rogerdale Road LIABLE FOR ANY INCIDENTAL  PUNI
71. nits    Pressure Units    Mass Total Units    Volume Total Units    Description    Sets the unit of mass flow rate for the selected  meter  Click wv to display all defined options     Note  If you change this value  the module  resets and clears all totals  No  conversion of units occurs     Sets the unit of temperature for the selected  meter  Click wv to display all defined options     Sets the unit of density for the selected meter   Click w to display all defined options     Sets the unit of pressure for the selected  meter  Click w to display all defined options     This read only field shows the Mass Total  Units of the selected meter  The units are  determined from Mass units selected above  without a time base  Note that units differ when  measuring liquids as compared to gas  Select  units accordingly     This read only field shows the Volume Total  Units of the Coriolis meter  The Volume units  are determined from the selections above  without a time base     3  Click Apply to save any changes you have made to this screen     4  Proceed to Section 3 1 8 to configure the Values tab     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1 8 Coriolis Setup and Values     Values    Use this screen to view the total accumulated volume and mass values  for the selected Coriolis meter     Note  The Values screen shown in Figure 13 is a composite  It is only  an example for documentation purposes and would
72. nsity at Today   s  Maximum Drive Gain    69 Volume Rate at  Today   s Maximum  Drive Gain    70 Today   s Minimum  Drive Gain Cycle Start  Time    71 Today   s Minimum  Drive Gain Cycle End  Time    Access    R O    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    FL    FL    FL    UINT32    UINT32    Length    Range    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    Any positive  floating point  number    0 235959    0 235959    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The maximum drive gain value  recorded during the current  contract day  Drive gain units are  percent     The average density value during  active dump cycles recorded  during the current contract day   Drive gain units are percent     The density value recorded when  the maximum drive gain value for  the current contract day occurred   Density units are determined  based on the configuration of the  meter     The volume rate recorded when  the maximum drive gain value for  the current contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the minimum drive gain  value for the current contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seco
73. nt Number    i ECPTBR2   Meter Tag   ECP TBR 2      General  Calibration   Diagnostics   Smart Meter Verification TBR TMR   Meter Zero   Units Config   Values   Current Dump Cycle   Dump Cycle Min Max Data   PVR    TBR  Liquid  Z TMR  Gas           Mode Status  433  TMR  Gas     Enabled Status  Inactive Pre Mist Ave Period  619    10 seconds  C Disabled Duration of Last  989    20 seconds Post Mist Adj Delay  620    6 seconds  Drive Gain  291    6 463333 x Drive Gain Threshold  617    5 0    Flowrates  TBR  Liquid  Control  624  Mass Flowrate Unremediated  247    0 0 Ibs hour  Timeout Mass Flowrate Remediated  973    0 0 Ibshour     Enabled Timeout Period  619    10 seconds    Disabled Totals  A 7 7   Mass Total U diated  259    32  Ib   Initial Action Drive Gain Averaging  r Apply to Flow saen Teste SES 5    Hold Last Value   One Second Cc Yes Mass Total Remediated  975    32 52808 Ibs     Set TBR Active Status Only C Four Seconds   No  Timeout Action Timeout Alarm Type Apply to Density    Show Actual Values   Slug Flow   Yes  C Alarm C Density OOL C No    Drive Gain Threshold  617    50 0    Lookback Period  620    5 seconds       Print Save As Auto Sean   7370       3  Close Apply   gt    ERNE 10 35AM                Figure 10  Coriolis Setup and Values     TBR TMR Tab    2  Review   and change as necessary   the values in the following    24 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Revised August 
74. oating point  number    Any positive  floating point  number    0 235959    0 235959    0 235959    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The minimum density value  recorded during the previous  contract day  Density units are  determined based on the  configuration of the meter     The drive gain value recorded  when the minimum density value  for the previous contract day  occurred  Drive gain units are  percent     The volume rate recorded when  the minimum density value for the  previous contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the maximum drive gain  value for the current contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The end time of the dump cycle in  which the maximum drive gain  value for the current contract day  was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The time at which the maximum  drive gain value for the current  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm    Name  66 Today   s Maximum  Drive Gain    67 Today   s Average Drive  Gain    68 De
75. on the  configuration of the meter     The total number of dump cycles  that have occurred during the  current month   The volume accumulated in the  current month  Volume units are  determined based on the  configuration of the meter     53    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    54    Parm       36    37    38    39    40    41    Name    Monthly Total  Accumulated Mass    Today   s Maximum  Density Cycle Start  Time    Today   s Maximum  Density Cycle End  Time    Today   s Maximum  Density Time of  Occurrence    Today   s Maximum  Density    Today   s Average  Density    Access    R W    R O    R O    R O    R O    R O    System  or User  Update  System    System    System    System    System    System    Data  Type  FL    UINT32    UINT32    UINT32    FL    FL    Length Range  4 Any positive  floating point  number  4 0 235959  4 0 235959  4 0 235959  4 Any positive  floating point  number  4 Any positive  floating point  number    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The mass accumulated in the  current month  Mass units are  determined based on the  configuration of the meter     The start time of the dump cycle in  which the maximum density value  for the current contract day was  recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds   
76. onfiguration     Note  For archive purposes  you should also save this configuration to  your PC   s hard drive or a removable media  such as a flash  drive  using the File  gt  Save Configuration option on the  ROCLINK 800 menu bar     Bg Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Chapter 4     Reference Materials    This section provides tables of information on the point types the MMI  Coriolis Interface module uses       Point Type 65  for the FB107  or Point Type 244  for the  ROC800 ROC800L     Revised August 2015 45    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     4 1 Point Type 65 244  Micro Motion Coriolis Interface Module    Point type 65  for FB107  or point type 244  for ROC800 ROC800L  contains the parameters for configuring the Coriolis Interface Application  module  The FB107 supports four logicals of this point type  corresponding to the four meter runs the FB107 supports  the ROC800 ROC800L  supports six logicals  corresponding to the six meter runs the ROC800 ROC800L supports     Point Type 65 244  Coriolis Interface Application Module    Parm       0 Point Tag ID    Name    1 Coriolis Modbus  Address    2 Polling Enable    3 Number of Retries    Poll Timeout  5 Actual Poll Period    46    Access    R W    R W    R W    R W    R W  R O    System   or User   Update  User    User    User    User    User  System    Data  Type  AC    UINT8   
77. onsidered  as no flow  This value allows the  module to identify the beginning  and end of dump cycles  Volume  accumulated below this cutoff  but  above the Coriolis meter   s low flow  cutoff is considered to be trickle  flow     For TBR  the current volume flow  rate retrieved from the meter  Rate  units are determined based on the  configuration of the meter     For TMR  the remediated volume  flow rate retrieved from the meter   Rate units are determined based  on the configuration of the meter     Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm System Data    Name Access or User Length Range Default Version    U Type  pdate  10 Volume Flow Rate R W System UINT16 2 0  15 253 0 1 00  Units  11 Live Mass Flow Rate R O System FL 4 Any positive 0 1 00  floating point  number  Live Mass Flow Rate R O System FL 4 Any positive 0 1 00  floating point  number    Revised August 2015    Description of functionality and  meaning of values    Volume Flow Rate Units     0   Unknown  15   Cubic feet minute  16   Gallons minute  17   Liters minute  18   Imperial gallons minute  19   Cubic meters hour  22   Gallons second  23   Million U S  gallons day  24   Liters second  25   Millions liters day  26   Cubic feet second  27   Cubic feet day  28   Cubic meters second  29   Cubic meters day  30   Imperial gallons hour  31   Imperial gallons day  130   Cubic 
78. otion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field    Total Volume    Total Mass    Accumulated Volume  During Trickle Flow    34    Description    These read only fields show the volumes  accumulated in the current contract day   Today   in the previous contract day   Yesterday   and in the current month   Monthly   The value in the Accumulated field  provides a running total for all dump cycles  is  updated after the completion of a dump cycle  and during trickle flow  and rolls over at  1 000 000 units  Configure units using the  Units Configuration tab     Once the contract day is over  the value in the  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These fields display only if you select  Dump Cycle as the Meter Mode on the  General tab    These read only fields show the mass   accumulated in the current contract day    Today   in the previous contract day    Yesterday   and in the current month    Monthly   The value in the Accumulated field   provides a running total for all dump cycles  is   updated after the completion of a dump cycle  and during trickle flow  and rolls over at   1 000 000 units  Configure units using the   Units Configuration tab     Once the contract day is over  the value in the  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These
79. read only field shows whether the  temperature for the meter   s RTD is out of  range  Valid values are Yes and No     This read only field shows whether the  temperature for the line   s RTD is out of range   Valid values are Yes and No     This read only field shows whether the  meter   s reported density is outside of standard  API ranges  Valid values are Yes and No     This read only field shows whether the  meter   s temperature is outside of standard  API ranges  Valid values are Yes and No     This read only field shows whether the RAM  diagnostic procedure  initiated during a power  reset  has failed  Valid values are Yes and  No     This read only field shows whether the  EEPROM Checksum procedure  initiated  during a power reset  has failed  Valid values  are Yes and No     This read only field shows whether the drive  is outside of its proscribed range  Valid values  are Yes and No     This read only field shows whether the  density is outside of standard limits  Valid  values are Yes and No     Communication Statistics    Number Requests  Sent to Meter    Number of Good  Responses    Number of Response  Timeouts    Number of Error  Reponses   Reset Comm Stats  Meter Information    Meter Model Type    20    This read only field shows the total number of  Modbus requests the module has sent to the  selected meter     This read only field shows the total number of  valid Modbus responses the module has  received from the selected meter     This read only field shows
80. rred    16   SMV Completed   0 15   SMV Aborted before  completion   Smart Meter Verification Inlet  Stiffness    0   In Limits    gt 0   Out of Limits    Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       127 SMV Outlet Stiffness    Name    128 Meter Model Type    129 SMV Percent  Complete   130 Raw tube frequency   Hz    131 LPO amplitude  volts     132 RPO amplitude  volts    133 Board temperature     C    134 Input voltage  volts     135 TBR status    136 Status Word 1    Access    R O    R O    R O  R O  R O  R O  R O  R O    R O    R O    System  or User  Update  System    System    System  System  System  System  System  System    System    System    Data  Type  UINT16    UINT8    UINT16  FLOAT  FLOAT  FLOAT  FLOAT  FLOAT    UINT8    UINT16    Length    2    Range    0 65535    0 1    0 100    Any floating point  number   Any floating point  number   Any floating point  number   Any floating point  number   Any floating point  number  Oor1    0 65535    Default    0    0 0    0 0    0 0    0 0    0 0    Version    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Smart Meter Verification Outlet  Stiffness    0   In Limits    gt 0   Out of Limits   Sensor Type   0   Curved Tube   1   Straight Tube   Percentage of the current SMV  procedure that is complete   Ra
81. s read only field shows the period of time   in seconds  between meter polls     This read only field shows the current  communication status with the selected meter   Valid values are Communication Disabled   Communicating  Configuring Slot Registers   Retrying  Response Timeout  Invalid CRC   Invalid Response Format  and Slot Register  Configuration Failed  Slow Poll Mode  Reset  Totals Failed  and Incompatible Target Device     Note     Slow poll mode    occurs when the  module   s poll request fails  all retries are  exhausted  and the device is not  responding  which might occur if the  connecting wire has been cult   In this  case  the device automatically slows  polling  shifting from a once per second  poll sequence to a once every 10   seconds poll sequence  Once the  communication problem is resolved   normal polling resumes within 10  seconds     Enables polling between the module and the  selected Coriolis meter  Valid values are  Enabled and Disabled  The default is  Disabled     Defines how the module handles flow  Valid  values are Continuous Flow and Dump  Cycle  The default is Continuous Flow     For liquid flow measurement  use Dump Cycle  mode  For gas flow measurement  use  Continuous mode     Sets the Flow Direction configured for the  meter  The default is Forward Only     Note  Bi Directional is available only when  using the Continuous Flow meter mode     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and
82. sed August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Chapter 1     Introduction    A Caution When using inputs that are not resident in the flow computer or RTU  that is     are provided by a communication mechanism  for control  ensure that a  supervisory system or mechanical safety equipment is in place to provide  proper function  While communication errors are noted in the device   s alarm  log  be aware that you may need to perform actions to prevent field issues     This chapter describes the structure of this manual and presents an  overview of the Micro Motion   Coriolis Interface module for the  FloBoss    107 Flow Manager  FB107  and the ROC800 Series Remote  Operations Controller  both the ROC800 and the ROC800L   The  Coriolis Interface module provides all of the functions necessary to  communicate with the core processor of a Micro Motion Coriolis meter  and includes an onboard RS 485 communications port that enables  communications between the module and the Coriolis meter without  using one of the communications ports of the FB107 or the  ROC800 ROC800L     Additionally  in simple allocation situations which do not require  custody transfer  one Coriolis Interface module  which connects with up  to six Coriolis meters  can take the place of transmitters  In situations  requiring custody transfer and the pulse counts transmitters provide   connecting the Coriolis Interface module to the transmitter pro
83. ser Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    System  PAON Name Access or User z AR Length Range  Update YP  121 Live zero  mass flow  R O System FLOAT 4 Any floating point  number  122 SMV Start Mode R W Userand UINT16 2 1 6  System  123 SMV State R O System UINT16 2 0 255  124 SMV Abort Code R O System UINT16 2 0 15  125 SMV State at Abort R O System UINT16 2 0 255  126 SMV Inlet Stiffness R O System UINT16 2 0 65535  66    Default    0 0    1    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Live zero  mass flow     Value sent to Meter to initiate the  Smart Meter Verification Process   1   Start with Output Fixed   6   Start with Continuous Values  Smart Meter Verification State    0   Not Running    gt 0   Running   Abort  Error  Code for the previous  SMV Procedure  Valid values are   0   No Error   1   User Initiated Abort   2   Drive Settle Time error   3   Frequency Drift   4   Drive voltage too high   5   Drive current too high   unstable drive    6   Drive current erratic  unstable  drive    7   General drive error   8   Delta T erratic   9   Delta T too high   10   State running   11   State complete   12  Meter verification data error  13   Unit has not been calibrated  on air   14   Unit has not been calibrated  on water   15   Meter verification  configuration items are not correct  Smart Meter Verification State  When Abort Occu
84. sitive  floating point  number    Any positive  floating point  number    Any positive  floating point  number  Any floating point  number  Any floating point  number  Any floating point  number    Default    0    0 0    0 0    0 0    0 0    0 0    0 0    Version    1 10    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Indicates the licensed features    Valid values are    0   SMV License   1   PVR License   2   TBR License   3   TMR License   Sends the SMV Start Mode to the   meter to begin the SMV process    or aborts the process if it is already   started   0   No Action   1   Start SMV by sending the SMV  Start Mode to the meter  or  send a 0 to the meter to abort  the SMV process   2   Start or Abort in progress    Defines how the module handles   flow    0   Continuous Flow Mode   1   Dump Cycle Flow Mode   Indicates if the TBR  Transient   Bubble Remediation  capabilities   of the meter have been enabled or   disabled    0   TBR Disabled   1   TBR Enabled   Current pressure compensation   effect on flow  This value is not   populated when a transmitter is   used    Current pressure compensation   effect on density  This value is not   populated when a transmitter is   used    Amount of time  in seconds  TBR   was active the last time it was   executed   Zero Standard Deviation    Left pickoff voltage  volts     Right pickoff voltage  volts     65    Micro Motion Coriolis Interface Module U
85. t bubbles    The mass accumulation of the  oil water mixture remediated for  any transient bubbles     The combined oil and water  volume total remediated for any  transient bubbles    The temperature at which the     corrected    flowrates and totals  have been corrected  This is  typically 60 deg F or 15 deg C  The  units are determined by the  associated temperature unit  selected  parameter 14     The density of    dry    oil at base  conditions  This is used to  calculate the water cut and  therefore determine the  percentage of oil versus water in  the stream  This value is obtained  by use of a petroleum analysis  laboratory or an external  calculation routine  The units  expected for the value are  determined by the associated  density unit selection  parameter  16      77    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System    oh Name Access or User ses Length Range  Update  200 Water Base Density R W User FLOAT 4 Any positive  floating point  number  78    Default    0 0    Version    1 10    Description of functionality and  meaning of values    The density of produced water at  base conditions  This is used to  calculate the water cut and  therefore determine the  percentage of oil versus water in  the stream  This value is obtained  by use of a petroleum analysis  laboratory or an external  calculation routine  The units  expected for the value are  determi
86. tatus of the meter zero  procedure    0   Complete   1   In Progress   2   Zeroing failed  zero too low  3   Zeroing failed  zero too high  4   Zeroing failed  zero too noisy    The value of the meter zero offset  previous to the last initiation of the  Start Meter Zero cycle     The value of the meter zero offset  as determined by the meter zero  procedure    The Volume Flow Cutoff currently  being used by the meter     The Volume Flow Meter Factor  currently being used by the meter     The Mass Flow Meter Factor  currently being used by the meter     The Density Meter Factor currently  being used by the meter     The total number of Modbus  requests sent to the Coriolis meter     The total number of valid Modbus  responses received from the  Coriolis meter     The total number of times a  response was not received from  the Coriolis meter     The total number of error Modbus  responses received from the  Coriolis meter     63    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    64    Parm       101    102    103    104    105    106    107    108    109    110    Name    Reset Communication  Statistics    Reset Totals    Today   s Total  Accumulated Trickle  Volume   Today   s Total  Accumulated Trickle  Mass   Yesterday s Total  Accumulated Trickle  Volume   Yesterday   s Total  Accumulated Trickle  Mass   Current Volume Total    Previous Volume Total    Current Mass Tota
87. ted for used in a non hazardous area     D gt     For best results  all Micro Motion Coriolis meter and transmitters  require 24Vdc power  The following table outlines the typical power  draw for standard Coriolis meter configurations  When designing an  application  consider these power requirements     Table 1  Configuration Power Requirements    Configuration 24 VDC Current  Sensor with Core Processor Only 768 mW 32 mA  Sensor with Core Processor  amp  Barrier 1440 mW 60 mA  Sensor with 1500 2500 Transmitter 3432 mW 143 mA  Sensor with 1700 2700 Transmitter 6000 mW 250 mA  Sensor with 3700 Net Oil Transmitter 7420 mW 309 mA    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107      This page is intentionally left blank      8 Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Chapter 3     Configuration    After you have successfully installed the MMI Coriolis Interface  module and wired the meter to the module  start ROCLINK 800 and  configure the module using the Coriolis Setup and Values screen  see  Section 3 1   Use the screen     and its component tabs     to configure  communications with the Coriolis meter  perform calibration  view flow  rates and totals  and view diagnostic information     To ensure that the device recognizes the module  you must perform a  warm start  ROC  gt  Flags  gt  Warm Start         Note  Once the module is installed  you can identif
88. the Meter Mode and  either Forward Only or Bi Directional  as the Flow Direction Mode on the  General tab     These read only fields show the mass  accumulated in the current contract day   Today   in the previous contract day   Yesterday   and in the current month   Monthly   The value in the Accumulated field  provides a running total for all dump cycles  is  updated after the completion of a dump cycle  and during trickle flow  and rolls over at  1 000 000 units Configure units using the Units  Configuration tab     Once the contract day is over  the value in the  Today field resets to zero  and the last value  recorded by the meter becomes the value of  the Yesterday Total Volume field     Note  These fields display only if you select  Dump Cycle as the Meter Mode and  either Forward Only or Bi   Directional as the Flow Direction  Mode on the General tab     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Field Description  Reverse Total These read only fields show the volumes  Volume accumulated in the current contract day     Today   in the previous contract day   Yesterday   and in the current month   Monthly   The value in the Accumulated field  provides a running total for all dump cycles  is  updated after the completion of a dump cycle  and during trickle flow  and rolls over at  1 000 000 units  Configure units using the  Units Configuration tab     Once the contract day is over  the value in th
89. tion     Revised August 2015    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 2 Saving the Configuration    Whenever you modify or change the configuration  it is a good practice  to save the final configuration to memory  To save the configuration     1  Select ROC  gt  Flags  The Flags screen displays      Flags Eam             Restart Flash Memory    Warm Start   Save Configuration      Clear    Cold Start      tatus      Cold Start  amp  Clear Alarms E vents   agus  Cold Start  amp  Clear Displays      Cold Start  amp  Clear FST s    Cold Start  amp  Clear History      Cold Start  amp  Clear ALL        2  Update   Y OK   X Cancel     Apply    Figure 17  Flags screen          2  Click Save Configuration  A verification message displays     l       Q Perform Flash Memory Save Configuration     1 No      Figure 18  Perform screen          3  Click Yes to begin the save process  The Status field on the Flags  screen displays In Progress  When the process completes  the  following message displays     Revised August 2015 43    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107         ROCLINK 800     gt    Flash Memory Save Configuration   COMPLETED     Flash Configuration bytes free   42576          Figure 19  Save Confirmation    4  Click OK  The Status field on the Flags screen displays Completed     5  Click Update on the Flags screen  This completes the process of  saving your new c
90. trieved from the meter   number Temperature units are determined  based on the configuration of the  meter   14 Temperature Units R W System UINT16 2 0  32 35 0 1 00 Temperature Units     0   Unknown  32   Degrees C  33   Degrees Fahrenheit  34   Degrees Rankine  35   Kelvin    50 Revised August 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module  System    DAN Name Access or User z n  Update yp  15 Live Flowing Density R O System FL  16 Density Units R W System UINT16  17 Live Drive Gain R O System FL  18 Dump Cycle Status R O System UINT8  19 Current Dump Cycle R O System UINT32  Start Time  20 Current Dump Cycle R O System UINT32  End Time    Revised August 2015    Length    Range  Any positive    floating point  number    0  90 104    Any positive  floating point  number    0 1    0 235959    0 235959    Default    0    Version    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    Current Density value retrieved  from the meter  Density units are  determined based on the  configuration of the meter     Density Units     0   Unknown  90   Specific gravity units  91   Grams cubic centimeter  92   Kilograms cubic meter  93   Pounds gallon  94   Pounds cubic foot  95   Grams milliliter  96   Kilograms liter  97   Grams liter  98   Pounds cubic inch  99   Short tons  2000  pounds  cubic yard  104   Degrees API    Current Drive Gain value
91. ues     Diagnostics Tab    Use this screen to view the meter status and diagnostic messages for the  selected Coriolis meter  To access this screen     1  Select the Diagnostics tab  The Diagnostic screen displays       ROCLNK 800    Coriolis Setup and Values   FB107       File Edit View ROC Configure Meter Utilities Tools Window Help  Dw el Gt E HUM SONE    Point Number   1   ECP TBR 2 X Meter Tag   ECP TBR 2    General  Calibration f Smart Meter Verification   TBR TMR   Meter Zero   Units Config   Values   Current Dump Cycle   Dump Cycle Min Max Data   PYR    Meter Status  419   Sensor Failure  NO  Data Loss Possible  NO  Flow Direction  FORWARD  Meter RTD Temp Out of Range  NO  Line RTD Temp Out of Range  NO             Curr Pressure Compensation  Effect on Flow  991      Curr Pressure Compensation  Effect on Dens  993       Density Outside Standard Range  NO  Temp Outside Standard Range  NO  RAM Diagnostic Failure  NO  EEPROM Checksum Failure  NO  Drive Overrange  NO   Density Outside of Limits  NO    joo    a   24 9203  fizg9e992 v  a    Board Temperature  383     Input Voltage  385      Live Zero  293      Zero Standard Deviation  231       Communication Statistics  Number Requests Sent to Meter    Number of Good Responses      Device Type  120   700 Core Processor  800 Enhanced Core Processor    0 0  134 4181 Hz  0 460457 Y    Raw Tube Frequency  285     Left Pickoff Voltage  287       Revised August 2015    1500 Transmitter  1700 Transmitter  2500 Transmitter  2700 Tr
92. umber of seconds in the timeout  period has passed and the TBR event is still  active  Default is Show Actual Values     Determines the type of alarm that the module   triggers in the event of TBR timeout  Valid   values are Slug Flow or Density OOL  out of   limits   Default is Slug Flow    Note  You must also set the Timeout Action  option to Alarm     Determines if the TBR event modifies the  density calculations  Default is Yes    Sets the Drive Gain percentage above which  the system initiates a TBR event  The default  is 1 8     25    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     26    Field  Lookback Period    TMR  Gas   Pre Mist Ave Period    Post Mist Adj Delay    Drive Gain Threshold    Mass Flowrate  Unremediated    Mass Flowrate  Remediated    Mass Total  Unremediated    Mass Total  Remediated    Description    Sets the number of seconds back in time from  which the program calculates the last  measured value  LMV  for density  Valid  values range from 5 to 30 seconds  Default is  0     Defines  in seconds  the application goes  back in time to determine the density to use in  TMR remediation     Defines  in seconds  how long the application  waits before beginning density adjustments  due to TMR     Sets the Drive Gain percentage that triggers a  TMR event  The default is 1 8     This read only field shows the mixture   s  unremediated mass flow rate     This read only field shows the mixture   s  remediated mass f
93. ust 2015    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm       192    193    194    195    196    197    198    199    Name    Net Oil Total  Uncorrected    Net Oil Total Correcte  Mix Mass Total  Unremediated    Mass Flowrate  Remediated    Mass Total  Remediated    Volume Total  Remediated    Reference Temp    Oil Base Density    Revised August 2015    Access    R W    R W    R W    R W    R W    R W    R W    R W    System  or User  Update  System    System    System    System    System    System    User    User    Data  Type  FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    FLOAT    Length    4    Range    Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number  Any positive  floating point  number    Any positive  floating point  number    Default    0 0    0 0    0 0    0 0    0 0    0 0    0 0    0 0    Version    1 10    1 10    Description of functionality and  meaning of values    The volume accumulation of the oil  at line  flowing  conditions     The volume accumulation of the oil  at reference  base  conditions     The mass accumulation of the  oil water mixture as directly  measured by the meter    The mass flowrate of the oil water  mixture remediated for any  transien
94. vides  extensive real time analysis of flow data     APP 485 application modules for the ROC800 ROC800L and FB107   including the Micro Motion Coriolis Interface module  streamline the  installation process by automatically installing all point types and  screens that are part of the application  APP 485 modules can house a  variety of applications  for further information about additional APP  485 modules  contact your sales representative     1 1 Scope and Organization    Revised August 2015    This document serves as the user manual for the Micro Motion Coriolis  Interface Module  which is intended for use in a FB107 or  ROC800 ROC800L  This manual describes how to install and configure  the Coriolis Interface module  referred to as the    Coriolis Interface    or     the module    throughout the rest of this manual   You access and  configure this module using ROCLINK    800 configuration software  loaded on a personal computer running Microsoft   Windows   2000   with Service Pack 2   Windows XP  Windows Vista  or Windows 7     The sections in this manual provide information in a sequence  appropriate for first time users  Once you become familiar with the  procedures and the software  the manual becomes a reference tool     This manual has the following major sections     Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107       Chapter l     Introduction     Chapter 2     Installation     Chapter 3     Configuration    Chapter 4  
95. w tube frequency  Hz     LPO amplitude  volts   RPO amplitude  volts   Board temperature    C   Input voltage  volts     Set by METER  if TBR option is   activated  to indicate current   status    Status Word 1    Bit 0   Core EEPROM Checksum  Error   Bit 1   Core RAM Test Error   Bit 2   Real Time Interrup Failure   Bit 3   Sensor Failure   Bit 4   Temperature Sensor Out   of Range   Bit 5   Calibration Failure   Bit 6   Other Failure   Bit 7   Transmitter  Initializing Warming Up   Bit 8   PV Out of Limits   Bit 9   Non PV Out of Limits   Bit 10   Simulation Mode Active   Bit 11   Undefined   Bit 12   Watchdog Error   Bit 13   Cold Start   Bit 14   Transmitter Configuration  Changed   Bit 15   Fault    Revised August 2015    67    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    Parm System Data  a Name Access or User Length Range Default Version    Type  Update  137 Status Word 2 R O System UINT16 2 0 65535 0 1 00    68    Description of functionality and  meaning of values    Status Word 2    Bit 0   Primary mA Output  Saturated   Bit 1   Secondary mA Output  Saturated   Bit 2   Primary mA Output Fixed   Bit 3   Secondary mA Output  Fixed   Bit 4   Density Outside Limits   Bit 5   Drive Over Range   Bit 6   PIC Daughterboard  Communication Failure   Bit 7   External Input Failure   Bit 8   Core EEPROM Checksum  Error   Bit 9   Core RAM Error   Bit 10   Sensor Not Respon
96. y a ROC800  Coriolis Interface module from the label on the face of the  module  On the FB107  the label is on the side of the physical  case  Using ROCLINK 800  click the APP 485 module shown in  the ROCLINK 800 graphic display  A label appears identifying  the module  see Figures 3 and 4               Figure 3  Micro Motion Coriolis Interface Module  FB107     Revised August 2015 9    Micro Motion   Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     3 1    10    MAR AS ee      os hal Be Re ay       o  s car  a Kae  C i    2   4         s 5h  a            s A  s   9    Shed eho be Te   Sia    eo  634620 93    Li       DoCeees ke ve    a    Figure 4  Micro Motion Coriolis Interface Module  ROCS amp 00     You must configure the module before you can establish  communications with the Coriolis meter  To configure the module  after  successfully installing and wiring the module  proceed through the  screens as shown in this chapter     Coriolis Setup and Values Screen    For the ROC800    For the FB107    Note  The Coriolis Setup and Values screen is identical for both the    FB 107 and ROC800 ROC800L     Use this screen to configure communications with the Coriolis meter   perform meter calibration  view flow rates and totals  and view  diagnostic information  To access this screen     1     From the Directory Tree  double click User Display     Double click Display  66     Coriolis Setup and Values  The  Coriolis Setup and Values screen displays  
97. y positive  floating point  number  4 Any positive  floating point  number  4 Any positive  floating point  number  4 Any positive  floating point  number  4 0 235959    Default    0    Version    1 00    1 00    1 00    1 00    1 00    1 00    Description of functionality and  meaning of values    The time at which the maximum  drive gain value for the previous  contract day was recorded     Byte 3   Unused  Byte 2   Hours  Byte 1   Minutes  Byte 0   Seconds    The maximum drive gain value  recorded during the previous  contract day  Drive gain units are  percent     The average drive gain value  during active dump cycles  recorded during the previous  contract day  Drive gain units are  percent     The density value recorded when  the maximum drive gain value for  the previous contract day occurred   Density units are determined  based on the configuration of the  meter     The volume rate recorded when  the maximum drive gain value for  the previous contract day occurred   Volume units are determined  based on the configuration of the  meter     The start time of the dump cycle in  which the minimum drive gain  value for the previous contract day  was recorded    Byte 3   Unused   Byte 2   Hours   Byte 1   Minutes   Byte 0   Seconds    61    Micro Motion Coriolis Interface Module User Manual  for ROC800 Series and FloBoss    107     Point Type 65 244  Coriolis Interface Application Module    62    Parm       84    85    86    87    88    89    Name    Yesterday   s Minimum
    