Micro Motion Coriolis Interface Module User Manual
Contents
1. TMR Post Mist Adjust Delay 143 TBR Control 144 SMV Stiffness Setpoint 145 TBR Drive Gain Threshold TMR Drive Gain Threshold 146 Flow Damping 147 Mass Flow Cutoff 148 Density Calibration Point 1 D1 Revised August 2015 Access R W R W R W R W R W R W R W R W R W System or User Update User and System User and System User and System User and System User and System User and System User and System User and System User and System Data Type UNIT16 UNIT16 UINT8 FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT Length Range 5 to 30 5 to 30 0 127 Any floating point value Any positive floating point number Any positive floating point number 0 60 seconds 0 to High Mass Flow Limit of Sensor 0 5 g cc Default 0 0 0025 0 4 0 0 0 0 0 0 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values For TBR the number of seconds back in time to calculate density LMV For TMR the number of seconds the post mist is delayed TBR Control Bit 0 Initial Action 0 Hold Last Value 1 Set TBR Active Status Only Bit 1 Timeout Action 0 Show Actual Values 1 Alarm Bit 2 Drive Averaging 0 1 Second 1 4 Seconds Bit 3 Affects flow 0 Yes 1 No Bit 4 Affects Density 0 Yes 1 No Bit 5 Timeout Alarm Type 0 Slug F
2. UNIT8 FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT Length 4 Range Any positive floating point number 0 1 Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Amount of mass accumulated by the module This accumulator rolls over at 1 000 000 0 The flow direction as read from the meter 0 Forward Direct 1 Reverse The volume accumulated in the current contract day Volume units are determined based on the configuration of the meter The volume accumulated in the previous contract day Volume units are determined based on the configuration of the meter The volume accumulated in the previous month Volume units are determined based on the configuration of the meter Amount of reverse volume accumulated by the module This accumulator rolls over at 1 000 000 0 The mass accumulated in the current contract day Mass units are determined based on the configuration of the meter The mass accumulated in the previous
3. 1 00 1 00 1 00 Description of functionality and meaning of values The volume accumulated during the current in progress or most recently completed dump cycle Volume Total units are determined based on the configuration of the meter The maximum density during the current in progress or most recently completed dump cycle Density units are determined based on the configuration of the meter The maximum drive gain during the current in progress or most recently completed dump cycle Drive Gain units are percent The minimum density during the current in progress or most recently completed dump cycle Density units are determined based on the configuration of the meter The minimum drive gain during the current in progress or most recently completed dump cycle Drive Gain units are percent The number of dump cycles that have occurred in the current contract day The volume accumulated in the current contract day Volume Total units are determined based on the configuration of the meter Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 28 Volume Total Units Name 29 Today s Total Accumulated Mass 30 Mass Total Units 31 Yesterday s Total Number of Dump Cycles 32 Yesterday s Total Accumulated Volume 33 Yesterday s Total Accumulated Mass 34 Mont
4. Click to begin the verification process Note The label on this button changes with the state of the verification Once the verification begins the label changes to Abort 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 5 to configure the TBR TMR tab Revised August 2015 23 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 5 Coriolis Setup and Values TBR TMR Transient bubble remediation TBR applies only to liquid flow transient mist remediation TMR applies only to gas flow This screen displays only if the connected Micro Motion Coriolis device has the factory enabled TBR or TMR feature Otherwise the message Feature not supported on this Micro Motion meter displays Additionally If you are connecting to a Micro Motion transmitter models 1500 1700 2500 2700 or 3000 series this tab is not available Use this screen to configure and view the TBR and TMR settings for the selected Coriolis meter Note The TBR TMR screen shown in Figure 10 is a composite showing both TBR and TMR values It is only an example for documentation purposes and would not occur in a live system To access this screen 1 Select the TBR TMR tab The TBR TMR screen displays E ROCLINK 800 Coriolis Setup and Values FB107 Sto File Edit View ROC Configure Meter Utilities Tools Window Help X Dee Qt Ww Se OM Poi
5. From the Directory Tree double click Application Module Double click MMI Coriolis Intfc Double click Display 66 Coriolis Setup and Values Double click 1 Meter 1 The Coriolis Setup and Values screen displays Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 E pd ROCLINK 800 Coriolis Setup and Values FB107 Soa File Edit View ROC Configure Meter Utilities Tools Window Help eI x Dei Gt t Wiha Mihi s 4 Ol amp Point Number EA M Meter Tag ECP TBR 2 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PVR Communications Micro Motion Coriolis Licensed Features Modbus Address 313 2 Poll Mode PYR Production Volume Reconciliation Poll Timeout 1 0 seconds a Enabled I SMY Smart Meter Verification eels 7 TBR Liquid Transient Bubble Remediation Number of Retries 3 Actual Poll Period 0 95 seconds Con Stu URSA lll Meter Mode Continuous Flow C Dump Cycle I TMR Gas Transient Mist Remediation Flow Direction Mode 17 Forward Only C Reverse Only Bi Directional Live Coriolis Values Forward Volume FlowfR ate 253 US gal hour Mass Flow ate 247 kg hour Sensor Tempespture 251 F Flowing Dansity 249 afem 3 DrivefGain 291 B Print Save As Auto Scan Update Close
6. Reference This manual assumes that you are familiar with the FB107 and the ROC800 ROC800L and its configuration For more information refer to the following manuals FloBoss 107 Flow Manager Instruction Manual part D301232X012 ROC800 Series Remote Operations Controller Instruction Manual part D301217X012 ROCLINK 800 Configuration Software User Manual for FloBoss 107 part D301249X012 ROCLINK 800 Configuration Software User Manual for ROC800 Series part D301250X012 ROCLINK 800 Configuration Software User Manual for ROCSOOL part D301246X012 1 2 Product Overview The MMI Coriolis Interface module enables the FB107 or the ROC800 ROC800L to communicate directly with the core processor in up to 6 4 on the FB107 Micro Motion Coriolis meters on the same EIA 485 RS 485 communications port The module provides its own communications port for this purpose The module serves as an interface between Coriolis meters transmitters and the FB107 or ROC800 ROC800L retrieving validating and then processing the data By supporting multiple core processors or transmitters at one time the module eliminates the need to have one transmitter for each core processor Additionally it removes the need for a water cut probe in a 2 phase separator for liquid output Finally it manages transient mist remediation TMR transient bubble remediation TBR production value reconciliation PVR meter zeroing a
7. 4 0 235959 4 Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The drive gain value recorded when the maximum density value for the current contract day occurred Drive gain units are percent The volume rate recorded when the maximum density value for the current contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the minimum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the dump cycle in which the minimum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the minimum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The minimum density value recorded during the current contract day Density units are determined based on the configuration of the meter 55 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 56 Parm 48 49 50 51 52 53 Name Drive Gain at Today s Minimum Density Volume Rate at Today s Minimum Density Yesterday s
8. Drive Gain Cycle End Time Yesterday s Minimum Drive Gain Time of Occurrence Yesterday s Minimum Drive Gain Density at Yesterday s Minimum Drive Gain Volume Rate at Yesterday s Minimum Drive Gain Meter Zero Access R O R O R O R O R O R W System or User Update System System System System System User and System Data Type UINT32 UINT32 FL FL FL UINT8 Length Range 0 235959 0 235959 Any positive floating point number Any positive floating point number Any positive floating point number 0 1 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The end time of the dump cycle in which the minimum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the minimum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The minimum drive gain value recorded during the previous contract day Drive gain units are percent The density value recorded when the minimum density value for the previous contract day occurred Density units are determined based on the configuration of the meter The volume rate recorded when the minimum drive gain value for the previous contract day occurred Volume units
9. FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT UINT16 UINT16 FLOAT FLOAT FLOAT FLOAT Length 4 4 ine Range 0 5 g cc 1000 50000 1000 50000 20 to 20 Any positive floating point number 0 5 g cc 0 5 g cc Any positive floating point number Any positive floating point number 0 65535 0 65535 240 to 450 C 1 5 to 10000 BAR 0 1 to 0 1 0 1 to 0 1 Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Density Calibration Point 2 D2 Tube Period D1 K1 Tube Period D2 K2 Density Temperature Correction DT Density Flow Correction FD Slug Flow High Density Limit g cc Slug Flow Low Density Limit g cc The maximum Mass flow rate that the sensor can detect The maximum volume flow rate that the sensor can detect Identifies the type of device attached to the module Valid values are 40 700 Core Processor 50 800 Enhanced Core Processor 36 1500 Transmitter 37 2500 Transmitter 41 1700 Transmitter 42 2700 Transmitter 65 3000 series transmitter Manufacturer ID External temperature input value External pressure input value Pressure correction factor for mass flow Pressure correction factor for density Revised August 2015 Micro Motio
10. gt EERE 251 Pw Figure 5 Coriolis Setup and Values Notes The Coriolis Setup and Values screen has a tab format Sections 3 1 1 through 3 1 71 discuss the requirements for each tab on the Coriolis Setup and Values screen Two fields Point Number and Meter Tag at the top of the screen appear on all tabs see Figure 5 For many fields on these screens bracketed numbers follow the field labels see Figure 5 These numbers identify the specific Modbus register in the Coriolis meter s core processor that provides the value 1 Review the values in the following fields Field Description Point Number Selects the Coriolis meter to configure Click v to display a drop down menu of all meters Meter Tag Sets a short 10 character identifier for the selected Coriolis meter Note The default value for the Point Number field is x Meter x corresponding to the number of meters your device supports 1 Meter 1 2 Meter 2 and so on Similarly Meter Revised August 2015 11 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Tag is the default value for the Meter Tag field until you provide a value The values displayed in the examples in this documentation are for illustrative purposes only and do not reflect the factory default 2 Click Apply to save any changes you have made to this screen 3 Proceed to Section 3 1 1 to configure the General tab
11. 291 6 491933 Print Save As Auto Scan Update Close Apply ep gt DERE 251 Px Figure 6 Coriolis Setup and Values General Tab 1 Review the values in the following fields Field Description Communications Modbus Address Enter the Modbus address of the target Coriolis device Valid values are 1 15 32 47 64 79 and 96 110 The default is 255 Note The Modbus address you select must be unique and not assigned to any other meter connected to this module That is you cannot select Address 2 for meter 2 if that address is already assigned to meter 1 13 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Poll Timeout Number of Retries Actual Poll Period Comm Status Poll Mode Meter Mode Flow Direction Mode Live Coriolis Values 14 Description Sets the amount of time in seconds the program waits to receive a response from a Coriolis meter If a response is not received within the specified time period the message is retried or the meter is marked with a response timeout status in the Comm Status field Sets the number of times the program attempts to successfully communicate with the selected Coriolis meter before issuing a response timeout status in the Comm Status field If a meter does not respond within the specified number of retries the program attempts to restore communications with the meter every 10 seconds Thi
12. Byte 0 Seconds The maximum density value recorded during the previous contract day Density units are determined based on the configuration of the meter Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 54 Yesterday s Average Density Name 55 Drive Gain at Yesterday s Maximum Density 56 Volume Rate at Yesterday s Maximum Density 57 Yesterday s Minimum Density Cycle Start Time 58 Yesterday s Minimum Density Cycle End Time 59 Yesterday s Minimum Density Time of Occurrence Revised August 2015 Access R O R O R O R O R O R O System or User Update System System System System System System Data Type FL FL FL UINT32 UINT32 UINT32 Length Range 4 Any positive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 0 235959 4 0 235959 4 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The average density value during active dump cycles recorded during the previous contract day Density units are determined based on the configuration of the meter The drive gain value recorded when the maximum density value for the previous contract day occurred Drive gain units are perc
13. FloBoss 107 Field Volume Flow Rate Mass Flow Rate Sensor Temperature Flowing Density Drive Gain Micro Motion Coriolis Licensed Features Description This read only field shows the current volume flow rate as reported by the meter Configure display units using the Units Configuration tab The Flow Direction Mode you select controls the values shown in this frame Values in the Forward column display only if you select Forward Only or Bi Directional Values in the Reverse column display only if you select Reverse Only or Bi Directional This read only field shows the current mass flow rate as reported by the meter Configure display units using the Units Configuration tab The Flow Direction Mode you select controls the values shown in this frame Values in the Forward column display only if you select Forward Only or Bi Directional Values in the Reverse column display only if you select Reverse Only or Bi Directional This read only field shows the current temperature value retrieved from the meter You configure the display units using the Units Configuration tab This read only field shows the current density value retrieved from the meter Configure display units using the Units Configuration tab This read only field shows as a percentage the current drive gain value This read only field shows the specific licensed features of the Coriolis meter which are currently active 2 Click Apply to
14. Mass Flow Meter Factor 279 1 0 Density Meter Factor 283 10 9 Flow Calibration Factor 72 5 02534 38 Temperature Calibration Factor 80 1 00000T 00000 Density Temp Correction DT 163 j5 Density Flow Correction FD 303 330 7675 Flow Calibration Pressure 271 bo 8 Flow Damping 189 o8 Print Save As Auto Scan Update Close Apply gt EERE 231 Pm Figure 7 Coriolis Setup and Values Calibration Tab 2 Review and change as necessary the values in the following fields 16 Field Volume Flow Cutoff Mass Flow Cutoff Volume Flow Meter Factor Mass Flow Meter Factor Description Sets the Volume Flow Cutoff value for the target Coriolis meter The default is 0 Sets the Mass Flow Cutoff value for the target Coriolis meter The default is 0 Sets the Volume Flow Meter Factor value for the target Coriolis meter Valid values are from 0 8 to 1 2 The default is 0 Sets the Mass Flow Meter value for the target Coriolis meter Valid values are from 0 8 to 1 2 The default is 0 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Revised August 2015 Field Density Meter Factor Flow Calibration Factor Temperature Calibration Factor Density Temp Correction DT Density Flow Correction FD Flow Calibration Pressure Flow Damping Density Calibration Points Tube Periods Slug
15. Maximum Density Cycle Start Time Yesterday s Maximum Density Cycle End Time Yesterday s Maximum Density Time of Occurrence Yesterday s Maximum Density Access R O R O R O R O R O R O System or User Update System System System System System System Data Type FL FL UINT32 UINT32 UINT32 FL Length Range 4 Any positive floating point number 4 Any positive floating point number 4 0 235959 4 0 235959 4 0 235959 4 Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The drive gain value recorded when the minimum density value for the current contract day occurred Drive gain units are percent The volume rate recorded when the minimum density value for the current contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the maximum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the dump cycle in which the maximum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the maximum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes
16. Print Save As Auto Scan Update Close Kh gt EERE 249P Figure 15 Coriolis Setup and Values Dump Cycle Min Max Data Tab 2 Review the values in the following fields Field Description Density Min Max Occurrences Cycle Start Time These read only fields show the start time of the dump cycle in which the minimum and the maximum density values were recorded during the current and the previous contract day 38 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Revised August 2015 Field Cycle End Time Time of Occurrence Min Max Density Value Average Density Drive Gain Value Volume Rate Description These read only fields show the end time of the dump cycle in which the minimum and the maximum density values were recorded during the current and the previous contract day These read only fields show the time at which the minimum and the maximum density values were recorded during the current and the previous contract day These read only fields show the minimum and the maximum density values recorded during the current and the previous contract day Units are configured in the Units Configuration tab These read only fields show the average density for the day at the moment when the minimum and the maximum density values were recorded during the current and the previous contract day Units are configured in the Units Configurat
17. The density value recorded when the minimum drive gain value for the current contract day occurred Density units are determined based on the configuration of the meter The volume rate recorded when the minimum drive gain value for the current contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the maximum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the dump cycle in which the maximum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 78 79 80 81 82 83 Name Yesterday s Maximum Drive Gain Time of Occurrence Yesterday s Maximum Drive Gain Yesterday s Average Drive Gain Density at Yesterday s Maximum Drive Gain Volume Rate at Yesterday s Maximum Drive Gain Yesterday s Minimum Drive Gain Cycle Start Time Revised August 2015 Access R O R O R O R O R O R O System or User Update System System System System System System Data Type UINT32 FL FL FL FL UINT32 Length Range 4 0 235959 4 An
18. The end time of the dump cycle in which the maximum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the maximum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The maximum density value recorded during the current contract day Density units are determined based on the configuration of the meter The average density value during active dump cycles recorded during the current contract day Density units are determined based on the configuration of the meter Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 42 43 44 45 46 47 Name Drive Gain at Today s Maximum Density Volume Rate at Today s Maximum Density Today s Minimum Density Cycle Start Time Today s Minimum Density Cycle End Time Today s Minimum Density Time of Occurrence Today s Minimum Density Revised August 2015 Access R O R O R O R O R O R O System or User Update System System System System System System Data Type FL FL UINT32 UINT32 UINT32 FL Length Range 4 Any positive floating point number 4 Any positive floating point number 4 0 235959 4 0 235959
19. Total Mass 9 92279 6 409236 16 33211 16 33211 bs Accumulated Volume During Trickle Flow 10 0 bo Bbls Accumulated Mass During Trickle Flow 0 00 Ibs Print Save As Auto Scan Update Close Apply gt EERE 2 34PM Revised August 2015 Figure 13 Coriolis Setup and Values Values Tab 31 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 32 2 Review the values in the following fields Field Reset Totals Contract Hour Reset Totals Description This read only field shows the contract hour as configured on the ROC gt Information screen Click to clear all totals and reset all minimum and maximum values stored in the module Totals Forward Only Reverse Only Bi Directional Forward Total Volume Forward Total Mass These read only fields show the volumes accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in the Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These fields display only if you select Continuous as
20. UINT8 UINT8 FL FL Length 10 A Range Default Version 0x20 0x7E for Logical 0 1 00 each ASCII Meter 1 character Logical 1 Meter 2 Logical 2 Meter 3 Logical 3 Meter 4 For ROC800 Logical 4 Meter 5 Logical 5 Meter 6 1 15 255 1 00 32 gt 47 64 gt 79 96 gt 110 0 1 0 1 00 0 255 3 1 00 0 5 15 0 1 0 1 00 Any positive 0 1 00 floating point number Description of functionality and meaning of values Point Type Description Modbus address of the target Coriolis meter Note this address cannot be changed to a value that is in use by another logical instance Enable communication with the target Coriolis meter 0 Polling Disabled 1 Polling Enabled The number of times communication with a Coriolis meter will be retried before a response timeout in the Comm Status parameter is set Poll timeout The time between polls to a meter in seconds Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System BA Name Access or User z AA Update yp 6 Comm Status R O System UINT8 1 0 10 0 1 00 Description of functionality and Length Range Default Version meaning of values Current communication status with the target meter 0 Communication Disabled 1 Communicating 2 Configuring Slot Registers 3 Retrying 4 Response T
21. are using transmitters you must use Micro Motion s ProLink software to change the comm settings on those transmitters to match these settings BO Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter 2 Installation General Procedure This chapter provides instructions for installing the Coriolis Interface module Read Section 1 3 of this manual for program requirements The FB107 and the ROC800 ROC800L each support only one Coriolis Interface module Note The FB107 can support only one APP 485 module If you already have an APP 485 based application in your FB107 consider which application is most appropriate for your needs Installation requires that you perform a number of steps in a specific sequence 1 Power down the FB107 or ROC800 ROC800L Install the application module refer to Section 2 1 Power up the FB107 or ROC800 ROC800L 2 3 Wire the module refer to Section 2 2 4 5 Configure the module refer to Chapter 3 2 1 Installing the Module The application module occupies the standard footprint of an FB107 or ROC800 ROC800L I O or communications module Place the module in any empty slot on the ROC800 ROC800L or FB107 To ensure that the device recognizes the module you must perform a warm start ROC gt Flags gt Warm Start 2 2 Wiring the Module Revised August 2015 Connect the Coriolis meter s to the co
22. are determined based on the configuration of the meter Perform Meter Zero The value of this parameter returns to 0 once the Start Meter process is complete 0 No action 1 Start Meter Zero Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 90 Meter Zero Status Name 91 Previous Meter Zero Offset 92 New Meter Zero Offset 93 Volume Flow Cutoff 94 Volume Flow Meter Factor 95 Mass Flow Meter Factor 96 Density Meter Factor 97 Number of Requests Sent to Meter 98 Number of Good Responses 99 Number of Response Timeouts 100 Number of Error Responses Revised August 2015 Access R O R O R O R W R W R W R W R O R O R O R O System or User Update System System System System System System System System System System System Data Type UINT8 FL FL FL FL FL FL UINT32 UINT32 UINT32 UINT32 Length Range Any valid floating point number 5 to 5 uS 0 to High Volume Flow Limit of Sensor 0 8 1 2 0 8 1 2 Any positive floating point number 0 4294967295 0 4294967295 0 4294967295 0 4294967295 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Current s
23. configure the units used for the selected Coriolis meter To access this screen 1 Select the Units Configuration tab The Unit Configuration screen displays E ROCLINK 800 Coriolis Setup and Values FB107 Soy File Edit View ROC Configure Meter Utilities Tools Window Help amp x Dee Gt H Ww MISON 2 wl 2K Point Number 2 ECP TMR 1 v Meter Tag ECP TMR 1 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero i Values Current Dump Cycle Dump Cycle Min Max Data PVR Units Volume Flow Rate Units 42 Lses i Mass Flow Rate Units 39 kg Temperature Units 41 e y Density Units 40 g em3 v Pressure Units 44 bar a Mass Total Units 45 Kilograms Volume Total Units 46 Liters Print Save As Auto Scan Update Close X do gt SOMEONES 11 15 4M Figure 12 Coriolis Setup and Values Units Config Tab 2 Review and change as necessary the values in the following fields Field Description Volume Flow Rate Sets the unit of volume flow rate for the Units selected meter Click w to display all defined options Note If you change this value the module resets and clears all totals No conversion of units occurs Revised August 2015 29 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 30 Field Mass Flow Rate Units Temperature Units Density U
24. fields display only if you select Dump Cycle as the Meter Mode on the General tab These read only fields show the volume accumulated while the meter was not in a dump cycle for the current Today contract day and for the previous contract day Yesterday The program updates these values whenever a dump cycle is not in progress Rollover occurs at 1 000 000 Configure units using the Units Configuration tab Note These fields display only if you select Dump Cycle as the Meter Mode on the General tab Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Accumulated Mass During Trickle Flow Description These read only fields show the mas accumulated while the meter was not ina dump cycle for the current Today contract day and for the previous contract day Yesterday The program updates these values whenever a dump cycle is not in progress Rollover occurs at 1 000 000 Configure units using the Units Configuration tab Note These fields display only if you select Dump Cycle as the Meter Mode on the General tab 3 Proceed to Section 3 1 9 to configure the Current Dump Cycle tab Revised August 2015 35 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 9 Coriolis Setup and Values Current Dump Cycle Note This screen is available only if you select Dump Cycle as the Meter Mode on the General
25. never occur in a live system To access this screen 1 Select the Values tab The Values screen displays Note The displayed fields on this screen depend on the values you select for Meter Mode and Flow Direction Mode in the General Tab The totals shown on the Values tab are based on the specified contract hour These totals are independent from the Force End of Day selection ROC gt Information and are not updated when you perform a Force End of Day r az ROCLINK 800 Coriolis Setup and Values Remote Oprtns Cntrir File Edit View ROC Configure Gas Meters Liquid Meters Utilities Tools Window Help E x Doe OF E v4 H Wi s 4ObkB Hh Point Number 1 Meter 1 X Meter Tag Meter 1 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Current Dump Cycle Dump Cycle Min Max Data PYR Reset Totals Totals Today Yesterday Monthly Accumulated fo Contract Hour NOTE Clicking this button will clear all current daily and monthly totals The Maximum and minimum Reverse values recorded during dump cycles will also be reset Total Volume 0 0 0 0 0 0 0 0 Bbls Reset Totals Total Mass 0 0 0 0 0 0 0 0 bs Total Mass 9 92279 6 409236 16 33211 16 33211 lbs Forward Total Volume 10 0 0 0 0 0 0 0 Bbls Totals Today Yesterday Monthly Accumulated Number of Dump Cycles f0 fo 0 TotalVolume o0 joo oo foo Bbs
26. retrieved from the meter Drive Gain units are percent The current status of a dump cycle 0 Complete 1 In Progress The start time of the current in progress or most recently completed dump cycle Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the current in progress or most recently completed dump cycle Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds 51 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 21 22 23 24 25 26 27 52 Name Current Dump Cycle Volume Accumulated Current Dump Cycle Maximum Density Current Dump Cycle Maximum Drive Gain Current Dump Cycle Minimum Density Current Dump Cycle Minimum Drive Gain Today s Total Number of Dump Cycles Today s Total Accumulated Volume Access R W R O R O R O R O R O R W System or User Update System System System System System System System Data Type FL FL FL FL FL UINT16 FL Length Range Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number 0 65536 Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00
27. save any changes you have made to this screen 3 Proceed to Section 3 1 2 to configure the Calibration tab Revised August 2015 15 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 2 Coriolis Setup and Values Calibration Tab Use this screen to perform and view meter calibration factors To access this screen 1 Select the Calibration tab The Calibration screen displays F E ROCLUINK 800 Coriolis Setup and Values FB107 File Edit View ROC Configure Meter Utilities Tools Window Help x 0 w amp Gt Whale 4 Ol KR Point Number 1 ECPTBR2 v Meter Tag ECP TBR 2 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Contig Values Current Dump Cycle Dump Cycle Min Max Data PVR Meter Calibration Factors Volume Flow Cutoff 197 11 0 Density Calibration Points Load Optimization 394 US gal hour Point 1 D1 155 0 0 g cc C Enabled Disabled ho Point 2 D2 157 1 0 g cc Most Flow Cutoff 130 Correction of Mass and Density for Pressure 82 g hour Tube Periods Enabled Disabled D1 K1 159 6394 586 D2 K2 161 7405 048 Slug Flow High Density Limit 199 5 0 g cc Low Density Limit 201 0 0 g cc Pressure Correction Factor Flow 267 01 Density 269 00 External Input Values Temperature 449 132 0 Pressure 451 6 894758 Volume Flow Meter Factor 281 1 1
28. tab Dump Cycle mode applies only to liquid flow Use this screen to view the current dump cycle information for the selected Coriolis meter To access this screen 1 Select the Current Dump Cycle tab The Current Dump Cycle screen displays r ROCLINK 800 Coriolis Setup and Values Remote Oprins Cntrir Soa File Edit View ROC Configure GasMeters Liquid Meters Utilities Tools Window Help ol x De Or v4 H ME SZORRI Point Number 1 Meter 1 v Meter Tag Meter 1 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Information Dump Cycle Minimum Flow foo Bbls day Status Complete Start Time 00 00 00 End Time 00 00 00 Volume Accumulated 0 0 Bbls Minimum Maximum Density 0 0 0 0 g cm 3 Drive Gain 0 0 0 0 Print Save As Auto Scan Update Close Apply gt DRENE 249P Figure 14 Coriolis Setup and Values Current Dump Cycle Tab 2 Review and change as necessary the values in the following fields Field Description Dump Cycle Sets the minimum flow rate for a dump cycle If Minimum Flow flow is less than this value the module assumes the dump cycle is closed and trickle flow accumulation is in effect 36 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Status Start Time End Time Volume A
29. the total number of instances when the program has not received a response within the timeout period from the selected meter This read only field shows the total number of erroneous Modbus responses the module has received from the selected meter Click to reset all communication statistics values displayed in the Communication Statistics frame This read only field shows the type of sensor for the selected meter Valid values are Curved Tube and Straight Tube Revised August 2015 Revised August 2015 Field Manufacturer ID Device Type Current Pressure Compensation Effect on Flow Current Pressure Compensation Effect on Density Board Temperature Input Voltage Live Zero Zero Standard Deviation Raw Tube Frequency Left Pickoff Voltage Left Pickoff Amplitude Right Pickoff Voltage Right Pickoff Amplitude tab Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Description This read only field shows the manufacturer s ID for the selected meter This read only field shows the specific type of meter or transmitter connected to the module This read only field shows the current pressure compensation effect on flow of the Coriolis meter Default value is 0 This read only field shows the current pressure compensation effect on density of the Coriolis meter Default value is 0 This read only field shows the board temperature of the selecte
30. 000 The default is 0 0 Sets in g cc the high and low density values for slug flow The high density limit should be greater than the low value Valid values are from 0 to 5 g cc The default is 0 0 Sets the values for Pressure Correction Factor for flow and density Valid values are from 0 1 to 0 1 The default is 0 0 Sets the values for External Input Values for temperature and pressure Valid temperature values range from 240 C to 450 C Valid pressure values range from 5 to 10000 BAR The default for both is 0 0 Enables Load Optimization Valid values are Enabled and Disabled Default is Disabled 17 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Description Correction of Mass Enables the module to calculate compensation and Density for for the effect of high pressure on the Pressure measurement accuracy of the Coriolis mass flow and density This calculation requires that you first provide flow and density values for the Pressure Correction Factors and you must provide a pressure value for the External Input Value Valid values are Enabled and Disabled The default is Disabled 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 3 to configure the Diagnostics tab 18 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 3 Coriolis Setup and Val
31. 07 Field Density Value Volume Rate Description These read only fields show the density value at the moment when the minimum and the maximum drive gain values were recorded during the current and the previous contract day Configure units using the Units Configuration tab These read only fields show the volume rate at the moment when the minimum and the maximum drive gain values occurred during the current and the previous contract day Configure units using the Units Configuration tab 3 Proceed to Section 3 1 11 to configure the PVR tab 40 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 11 Coriolis Setup and Values PVR This screen displays only if the connected Micro Motion Coriolis device has the factory enabled production volume reconciliation PVR feature Otherwise the message Feature not supported on this Micro Motion meter displays Use this screen to configure PVR parameters and view PVR related flow rates and totals To access this screen 1 Select the PVR tab The PVR screen displays T E ROCLINK 800 Coriolis Setup and Values FB107 Sax File Edit View ROC Configure Meter Utilities Tools Window Help x D Se Di E HU hn SA2ORR ef 2 Point Number EE Meter Tag ECP PVR 12 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Confia Values Current Dump
32. 12 Revised August 2015 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 1 Coriolis Setup and Values General Tab Use this tab which displays when you access the Coriolis Setup and Values screen to configure communications with one or more Coriolis meters configure and enable polling and set communications parameters E fo ROCLINK 800 Coriolis Setup and Values FB107 File Edit View ROC Configure Meter Utilities Tools Window Help Doe Bi tr Whew 4 OR ew Meter Tag ECP TBR 2 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PVR Point Number Micro Motion Coriolis Licensed Features Communications Modbus Address 313 2 Poll Mode PVR Production Volume Reconciliation Poll Timeout 11 0 seconds S HR SMY Smart Meter Verification isable IV TBR Liquid Transient Bubble Remediation I TMR Gas Transient Mist Remediation Number of Retries 3 Actual Poll Period 0 95 seconds Com Status CGR Meter Mode Continuous Flow C Dump Cycle Flow Direction Mode 17 Forward Only C Reverse Only Bi Directional Live Coriolis Values Forward Volume Flow Rate 253 00 US gal hour Mass Flow Rate 247 ao kg hour Sensor Temperature 251 7273302 F Flowing Density 249 fo e9s0508 g cm 3 Drive Gain
33. 2015 fields Field Mode Status Duration of Last Drive Gain TBR Liquid Control Timeout Timeout Period Initial Action Drive Gain Averaging Apply to Flow Timeout Action Timeout Alarm Type Apply to Density Drive Gain Threshold Description Indicates whether TBR or TMR is enabled on the selected meter This read only field shows the TBR or TMR status for the selected meter if the option is activated This read only field shows the number of seconds for the last recorded TBR or TMR event This read only field shows current drive gain value in percent retrieved from the selected meter Sets in seconds the amount of time the module holds the last measured value after first detecting a bubble Sets in seconds the amount of time the module holds the last measured value after first detecting a bubble Valid values range from 10 to 30 000 seconds The default is 10 seconds Indicates whether the module holds the last measured density value from the time period before transient bubbles were detected The Set TBR Active Status Only option allows for the indication of transient bubbles but takes no action Default is Hold Last Value Sets the number of seconds during which the module determines the average drive gain Default is 1 Second Determines if the TBR event affects the mass flow rate and accumulation Default is Yes Sets the behavior of the selected meter when the defined n
34. Cycle Dump Cycle Min Max Data PYR PYR Configuration Ref Temperature 319 zoo 8 hbs Dil Base Density 1959 08 g cm 3 Water Base Dens 1831 ho o g cm 3 PYR Flow Rates Uncorrected Corrected Water Cut 1555 57 0 0 0 0 z Net Water Flw 1562 49 o0 00 Bbls d Net Dil Flow 1553 47 foo 0 0 Bbls day Mix Mass Rate 247 00 kg hour Mix Volume Rate 253 oao Bbls day PYR Totals Uncorrected Corrected Net Water Flw 1667 63 1378 128 1322 181 Bbls Net Oil Flow 1665 61 293 3511 269 2446 Bbl Mix Mass 259 193686 1 kg Print Save As Auto Scan Update Close Apply ef gt DRENE 251 PM Figure 16 Coriolis Setup and Values PVR Tab Note Unit values on this screen are dynamic and reflect the values defined on the Units Config tab 2 Review the values in the following fields Field Description PVR Configuration Ref Temperature Sets the temperature to which corrected flowrates and totals have been corrected typically 60 F or 15 C Revised August 2015 AD Field Oil Base Density Water Base Dens PVR Flow Rates Water Cut Net Water Flw Net Oil Flow Mix Mass Rate Mix Volume Rate PVR Totals Net Water Flw Net Oil Flow Mix Mass Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Description Sets the density of dry oil at base conditions The module uses this value to calculate the water
35. Flow Pressure Correction Factor External Input Values Load Optimization Description Sets the Density Meter Factor value for the selected Coriolis meter Enter any decimal value greater than zero The system multiplies this value by the live density reading to produce the published density value Sets the Flow Calibration Factor value for the selected Coriolis meter The default is 0 Sets the Temperature Calibration Factor value for the selected Coriolis meter The default is 0 Sets the Density Temperature Correction value for the selected Coriolis meter Valid values are from 20 to 20 The default is 0 0 Sets the Density Flow Correction value for the selected Coriolis meter The default is 0 0 Sets the Flow Calibration Pressure value of the selected Coriolis meter Enter any decimal value greater than zero The default is 0 0 Sets the flow rate internal damping in seconds Valid values are from 0 to 60 seconds The default is 0 0 Sets the values for Density Calibration Point 1 D1 and Density Calibration Point 2 D2 Valid values are from 0 to 5 g cc The default is 0 0 Sets the values for Tube Period D1 K1 and Tube Period D2 K2 from the physical Coriolis sensor plates K1 is the tube period when the sensor is filled with a fluid of Density D1 K2 is the tube period when the sensor is filled with a fluid of Density D1 Both of these values are in units of microseconds Valid values are from 1000 to 50
36. Part D301753X012 August 2015 Micro Motion Coriolis Interface Module p User Manual for ROC800 Series and FloBoss 107 Controllers E ROCLINK 800 Coriolis Setup and Values FB107 File Edit View ROC Configure Meter Utilities Tools Window Help ax D S W D HAHM SORE RI Point Number fAs aA bd Meter Tag ECP TBR 2 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PVR Communications Micro Motion Coriolis Licensed Features Modbus Address 313 2 Poll Mode PYR Production Volume Reconciliation Poll Timeout hoo seconds Enabled I SMY Smart Meter Verification i C Disabled Aa 4 ons Naba of Maries B 7 TBR Liquid Transient Bubble Remediation I TMR Gas Transient Mist Remediation Actual Poll Period 0 95 seconds taas i i i Comm Status CSc Meter Mode Continuous Flow Dump Cycle Flow Direction Mode 17 Forward Only C Reverse Only Bi Directional Live Coriolis Values Forward Volume Flow Rate 253 10 0 US gal hour Mass Flow Rate 247 10 0 kg hour Sensor Temperature 251 72 73302 F Flowing Density 249 0 8980508 g cm 3 Drive Gain 291 6 491933 Print Save As Auto Scan 2 Update Close Apply gt EERE 251P k a s EMERSON Remote Automation Solutions Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Revis
37. TIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING Houston TX USA 77072 BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE T 1 281 879 2699 F 1 281 988 4445 AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER www EmersonProcess com Remote AND CLAIMS OF THIRD PARTIES Emerson Process Management Ltd Remote Automation Solutions UK is a wholly owned subsidiary of Emerson Electric Co doing business as Remote Automation Solutions a business unit of Emerson Process Management FloBoss ROCLINK ControlWave Helicoid and OpentEnterprise are trademarks of Remote Automation Solutions AMS PlantWeb and the PlantWeb logo are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co Emerson Process Management Emerson and the Emerson logo are trademarks and service marks of the Emerson Electric Co All other marks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as Middle East Africa Emerson Process Management Remote Automation Solutions Emerson FZE P O Box 17033 Jebel Ali Free Zone South 2 Dubai U A E T 971 48118100 F 971 4 8865465 www EmersonProcess com Remote Asia Pacific warranties or guarantees express or implied regarding the products or services described Em
38. Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PYR Perform Meter Zero Meter Zero Status 421 Complete Previous Meter Zero Offset 0 0 New Meter Zero Offset 233 0 0150895 Start Zero 5 Print Save As Auto Scan Update Close RE 11 13 4M Figure 11 Coriolis Setup and Values Meter Zero Tab 2 Review and change as necessary the values in the following fields Revised August 2015 27 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 28 Field Meter Zero Status Previous Meter Zero Offset New Meter Zero Offset Start Zero Description This read only field shows the current status of the meter zero procedure Valid values are Complete In Progress Zeroing failed Zero too low Zeroing failed Zero too high and Zeroing failed zero too noisy This read only field shows the value of the meter zero offset as determined by the previous meter zero procedure This read only field shows the value of the meter zero offset as determined by the most recent meter zero procedure Click to begin the meter zero procedure 3 Proceed to Section 3 1 7 to configure the Units Configuration tab Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 7 Coriolis Setup and Values Units Configuration Use this screen to
39. ansmitter 3000 Transmitter Number of Response Timeouts 1 0 4602637 Yy 0 897989 g cm 3 6 364013 0 4663078 Yy 0 4663078 Y Left Pickoff Amplitude 379 Flowing Density 249 Drive Gain 291 Right Pickoff Voltage 289 Right Pickoff Amplitude 381 Reset Comm Stats Meter Information Meter Model Type 3019 Curved Tube Straight Tube c Oj C Number of Error Responses 0 A C i C Manufacturer ID 121 m Print Save As Auto Scan 2 Update Close Apply gt EE oor Figure 8 Coriolis Setup and Values Diagnostics Tab 2 Review the values in the following fields Field Meter Status Sensor Failure Description This read only field shows the current status of the selected meter based on the value in the primary Coriolis status register Valid values are Yes and No This read only field shows the meter s possibility of data loss Valid values are Yes and No Data Loss Possible This read only field shows the meter s flow direction Valid values are Forward or Reverse Flow Direction 19 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Meter RTD Temp Out of Range Line RTD Temp Out of Range Density Outside Standard Range Temp Outside Standard Range RAM Diagnostic Failure EEPROM Checksum Failure Drive Overrange Density Outside of Limits Description This
40. ccumulated Density Drive Gain Description This read only field shows the current status of a dump cycle Valid values are Complete and In Progress This read only field shows the start time of the current in progress dump cycle This read only field shows the end time of either the current in progress or the most recently completed dump cycle This read only field shows the volume accumulated during either the current in progress or the most recently completed dump cycle Configure units using the Units Configuration tab These read only fields show the minimum and maximum density during either the current in progress or the most recently completed dump cycle Configure units using the Units Configuration tab These read only fields show in percent the minimum and maximum drive gain during either the current in progress or the most recently completed dump cycle 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 10 to configure the Dump Cycle Min Max Data tab Revised August 2015 37 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 10 Coriolis Setup and Values Dump Cycle Min Max Data Note This screen is available only if you select Dump Cycle as the Meter Mode on the General tab Use this screen to view density and drive gain minimum and maximum values cycle start and end times and volume rates for the s
41. contract day Mass units are determined based on the configuration of the meter The mass accumulated in the previous month Mass Total units are determined based on the configuration of the meter Amount of reverse mass accumulated by the module This accumulator rolls over at 1 000 000 0 75 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System or User Update 76 Parm 181 182 183 184 185 186 187 188 189 190 191 Name Volume Flow Rate Reverse Mass Flow Rate Reverse Mass Den Correction for Pressure Water Cut Uncorrected Water Cut Corrected Net Water Flow Uncorrected Net Water Flow Corrected Net Oil Flow Uncorrected Net Oil Flow Corrected Net Water Total Uncorrected Net Water Total Corrected Access R O R O R W R W R W R W R W R W R W R W R W System System User System System System System System System System System Data Type FLOAT FLOAT UNIT8 FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT Length Range 4 Any positive floating point number 4 Any positive floating point number 1 0 1 4 Any positive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 Any pos
42. cut and determine the percentage of oil versus water in the stream Value is obtained from a petroleum analysis laboratory or an external calculation routine Sets the density of produced water at base conditions The module uses this value to calculate the water cut and determine the percentage of oil versus water in the stream Value is obtained from a petroleum analysis laboratory or an external calculation routine These read only fields show the calculated water cut percentage where 100 is pure produced water and 0 is pure oil These read only fields show the volume flow rate of the water These read only fields show the mass flow rate of the liquid mixture unremediated by PVR This read only field shows the mass flow rate of the liquid mixture remediated for PVR This read only field shows the volume flow rate of the mixture remediated by PVR These read only fields show the net volume accumulation of the water The uncorrected value is at line flowing conditions and the corrected value is at reference temperature conditions These read only fields show the net volume total accumulation of the oil The uncorrected value is at line flowing conditions and the corrected value is at reference temperature conditions This read only field shows the mass accumulated total of the mixture unremediated for PVR 3 Click Close to return to the ROCLINK 800 screen Proceed to Section 3 2 to save your configura
43. d meter Default value is 0 This read only field shows the input voltage of the selected meter Default value is 0 This read only field shows the live zero in mass flow of the selected meter Default value is 0 This read only field shows the zero standard deviation value of the selected meter Default value is 0 This read only field shows the raw tube frequency in Hz of the selected meter Default value is 0 This read only field shows the left pickoff voltage of the selected meter Default value is 0 This read only field shows the left pickoff amplitude in volts of the selected meter Default value is 0 This read only field shows the right pickoff voltage of the selected meter Default value is 0 This read only field shows the right pickoff amplitude of the selected meter Default value is 0 3 Proceed to Section 3 1 4 to configure the Smart Meter Verification 21 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 4 Coriolis Setup and Values Smart Meter Verification Use this screen to view the Smart Meter Verification status for the selected Coriolis meter This screen displays only if Smart Meter Verification is available for that sensor and only if that sensor is connected to a Coriolis meter using the 800 enhanced core processor Note The message Feature not supported on this Micro Motion meter displays if this meter does not support Smart Meter Verificat
44. ding Bit 11 Temperature Sensor Out of Range Bit 12 Input Over Range Bit 13 Frequency Output Saturated Bit 14 Transmitter Not Characterized Bit 15 Real Time Interrupt Failure Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System PE Parm Data Description of functionality and Name Access Uh pu Type Length Range Default Version meaning of values 138 Status Word 3 R O System UINT16 2 0 65535 0 1 00 Status Word 3 Bit 0 Burst Mode Enabled Bit 1 Power Reset Occurred Bit 2 Transmitter Initializing Warming Up Bit 3 Sensor Xmtr Communication Failure Bit 4 Paper Out Bit 5 Event 2 Triggered Bit 6 Event 1 Triggered Bit 7 Sensor Xmtr Communication Failure Bit 8 Calibration Failure Bit 9 Excess Calibration Correction Auto Zero too Low Bit 10 Excess Calibration Correct Autozero too High Bit 11 Process too Noisy to Perform Auto Zero Bit 12 Transmitter Failed Bit 13 Data Loss Possible Bit 14 Calibration In Progress Bit 15 Slug flow Revised August 2015 69 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System ol Name Access or User We Update 139 Status Word 4 R O System UINT16 2 0 65535 0 1 00 Status Word 4 Bit 0 API VCF Temperature Outsid
45. e State at Abort Start Meter Verification Description Sets the stiffness setpoint for the Smart Meter verification Valid values range from 0 0025 to 0 4 Sets the value the meter uses when initiating the Smart Meter verification process Default is Start with Output Fixed This read only field shows the current state of the verification Valid values are Stopped and Running This read only field shows the completion percentage of the current verification procedure This read only field shows the inlet stiffness value for the verification Valid values are 0 In Limits and 1 Out of Limits This read only field shows the outlet stiffness value for the verification Valid values are O In Limits and 1 Out of Limits This read only field shows the Abort Error Code for the previous verification Valid values are 0 No Error 1 User Initiated Abort 2 Frequency Drift 3 Unstable flow 4 No Air 5 No Water Reference 6 Missing Configuration Data 7 General drive error 8 Delta T erratic 9 Delta T too high 10 State running 11 State completed 12 Meter verification data error 13 Unit has not been calibrated on air 14 Unit has not been calibrated on water 15 Meter verification configuration items are not correct This read only field shows the state of the verification when the last abort occurred Valid values are 16 SMV Completed and 0 15 SMV Aborted before completion
46. e Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These fields display only if you select Continuous as the Meter Mode and either Reverse Only or Bi Directional as the Flow Direction Mode on the General tab Reverse Total Mass These read only fields show the mass accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in the Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These fields display only if you select Dump Cycle as the Meter Mode and either Reverse Only or Bi Directional as the Flow Direction Mode on the General tab Totals Dump Cycle selected as Meter Mode on General tab Number of Dump These read only fields show the number of Cycles dump cycles that have occurred in the current contract day Today in the previous contract day Yesterday and for the current month Monthly Note These fields display only if you select Dump Cycle as the Meter Mode on the General tab Revised August 2015 33 Micro M
47. e Standard Bit 1 API VCF Line Density Outside Standard Range Bit 2 Line RTD Temperature Out of Range Bit 3 Case Meter RTD Temperature Out of Range Bit 4 Flow Direction 0 Forward 1 Reverse Bit 5 Factory Configuration Data is Invalid Bit 6 Enhanced Density Unable to fit curve data Bit 7 Last Measured Value Override Active Bit 8 Enhanced Density Extrapolation Alarm Bit 9 Cal Factors Unentered Bit 10 1000 2000 3000 EEPROM Checksum Error Bit 11 1000 2000 3000 RAM Test Error Bit 12 Unrecognized Unenterd Sensor Type Bit 13 Core Configuration Database Corrupt Bit 14 Core Power Down Totals Corrupt Bit 15 Core Program Corrupt 140 SMV Output State R W Userand UINT16 2 0 1 0 1 00 Smart Meter Verification Output System State during procedure 0 Last Value 1 Fault Value 141 TBR Timeout R W User and UNIT16 2 0 30 000 0 1 00 For TBR the amount of time in seconds System seconds that the last measured value will be held after a bubble is first detected TMR Pre Mist Average R W User and UNIT16 2 0 30 000 0 1 00 For TMR the amount of time in Period seconds System seconds for the pre mist period Description of functionality and Length Range Default Version meaning of values 70 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 142 TBR LMV Sample Position Name
48. eaeeeeeeeseeeeeseaeeeteaeeteaes 16 3 1 3 Coriolis Setup and Values Diagnostics Tab 0 cccesceeeeeeceeeeeseeeeeeeseeeeeeseaeeseneeesaes 19 3 1 4 Coriolis Setup and Values Smart Meter Verification ccccessccesssseeeeesssteeesseeeees 22 3 1 5 Coriolis Setup and Values TBR TMR 0 ccceecceeeeeeceeneeeeeeeeceaeeeeaaeeeeaeeseeaeeesaeeneaeeeeaes 24 3 1 6 Coriolis Setup and Values Meter Zer0 eseceeccceceeeeeseeceeeeeceeeeeaeeeeaeeseeeeeseaeeseaeeeeaes 27 3 1 7 Coriolis Setup and Values Units Configuration ccccccceeeceeeeeeceeeeeseeeeeeeaeeeeneeesaees 29 3 1 8 Coriolis Setup and Values Values 0 eceeeececeeeeeeeeeeeseeseeeeeaaeeesaaeeseaeeesaaeeesaeeeeees 31 3 1 9 Coriolis Setup and Values Current DUMP CyCle ccceeeeeeeseeeeeeneeseeeeeteaeeetaeenenes 36 3 1 10 Coriolis Setup and Values Dump Cycle Min Max Data cccceeeceeeeeeeeseeeeeseeteaes 38 3 1 11 Coriolis Setup and Values PVR cccceeccecesseeeeeeeeeeeeeeeeeeeeeeeceaeeesaaeeseaeeseeeeesaeeneneeeeaes 41 3 2 Saving the Configuratio Mennien oiiire anne aaia ia a a aaiae 43 Chapter 4 Reference Materials 45 4 1 Point Type 65 244 Micro Motion Coriolis Interface MOdUIe c ccceeeceeeeeeeeeeeeeteeeeeaeeeeneeeee 46 Revised August 2015 ili Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 This page is intentionally left blank iv Revi
49. elected Coriolis meter To access this screen 1 Select the Dump Cycle Min Max Data tab The Dump Cycle Min Max Data screen displays ROCLINK 800 Coriolis Setup and Values Remote Oprtns Cntrir Erima File Edit View ROC Configure GasMeters Liquid Meters Utilities Tools Window Help 5 xX Dw wd Gt k M ME SZORRI KERI Point Number i Meter i x Meter Tag Meter General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Contig Values Current Dump Cych Density Min Max Occurrences Today s Minimum Today s Maximum Yesterday s Minimum Yesterday s Maximum Cycle Start Time 00 00 00 00 00 00 00 00 00 00 00 00 Cycle End Time 00 00 00 00 00 00 00 00 00 00 00 00 Time of Occurrence 00 00 00 00 00 00 00 00 00 00 00 00 Min Max Density Value 0 0 o o o o o o a em 3 Average Density 00 joo t S joo 8 o0 gma Drive Gain Value joo t bo bo t an VolumeRate 0 0 joo t foo 8 o0 Bbls day Drive Gain Min Max Occurrences Today s Minimum Today s Maximum Yesterday s Minimum Yesterday s Maximum Cycle Start Time 00 00 00 00 00 00 00 00 00 00 00 00 Cycle End Time 00 00 00 00 00 00 00 00 00 00 00 00 Time of Occurrence 00 00 00 00 00 00 00 00 00 00 00 00 Min Max Drive Gain Value 0 0 0 0 0 0 o o Average Drive Gain bo bo t bo 8t bo Density Value 0 0 0 0 0 0 foo g om 3 Volume Rate oo oo bo t bo Bbls day
50. ent The volume rate recorded when the maximum density value for the previous contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the minimum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the dump cycle in which the minimum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the minimum density value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds 57 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 58 Parm 60 61 62 63 64 65 Name Yesterday s Minimum Density Drive Gain at Yesterday s Minimum Density Volume Rate at Yesterday s Minimum Density Today s Maximum Drive Gain Cycle Start Time Today s Maximum Drive Gain Cycle End Time Today s Maximum Drive Gain Time of Occurrence Access R O R O R O R O R O R O System or User Update System System System System System System Data Type FL FL FL UINT32 UINT32 UINT32 Length Range Any positive floating point number Any positive fl
51. erson Process Management herein or their use or applicability Remote Automation Solutions reserves the right to modify Remote Automation Solutions or improve the designs or specifications of such products at any time without notice All sales 1 Pandan Crescent are governed by Remote Automation Solutions terms and conditions which are available upon Singapore 128461 request Remote Automation Solutions does not assume responsibility for the selection use or T 65 6777 8211 F 65 6777 0947 maintenance of any product Responsibility for proper selection use and maintenance of any www EmersonProcess com Remote Remote Automation Solutions product remains solely with the purchaser and end user Remote Automation Solutions EMERSON
52. essure Units Valid values are 0 Unknown 1 Inches water 68 degrees Fahrenheit 2 Inches mercury 0 degrees Celsius 3 Feet water 68 degrees Fahrenheit 4 Millimeters water 68 degrees Fahrenheit 5 Millimeters mercury 0 degrees Celsius 6 Pounds square inch 7 Bar 8 Millibar 9 Grams square centimeter 10 Kilograms square centimeter 11 Pascals 12 Kilopascals 13 Torr 0 degrees Celsius 14 Atmospheres 145 Inches water 60 degrees Fahrenheit 237 Megapascals 238 Inches water 4 degrees Celsius 239 Millimeters water 4 degrees Celsius Flow Calibration Factor FCF Temperature Calibration Factor Amount of volume accumulated by the module This accumulator rolls over at 1 000 000 0 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 171 Mass Accumulated Name 172 Flow Direction Calculated 173 Rev Volume Today 174 Rev Volume Yesterday 175 Rev Volume Monthly 176 Rev Volume Accumulated 177 Rev Mass Today 178 Rev Mass Yesterday 179 Rev Mass Monthly 180 Rev Mass Accumulated Revised August 2015 Access R W R W R W R W R W R W R W R W R W R W System or User Update System System System System System System System System System System Data Type FLOAT
53. feet hour 131 Cubic meters minute 132 Barrels second 133 Barrels minute 134 Barrels hour 135 Barrels day 136 U S gallons hour 137 Imperial gallons second 138 Liters hour 253 Special For TBR the current mass flow rate retrieved from the meter Mass rate units are determined based on the configuration of the meter For TMR the unremeditated mass flow rate retrieved from the meter Mass rate units are determined based on the configuration of the meter 49 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System ge Name Access or User AR Update yp 12 Mass Flow Rate Units R W System UINT16 2 0 70 253 0 1 00 Mass Flow Rate Units Description of functionality and Length Range Default Version meaning of values 0 Unknown 70 Grams second 71 Grams minute 72 Grams hour 73 Kilograms second 74 Kilograms minute 75 Kilograms hour 76 Kilograms day 77 Metric tons minute 78 Metric tons hour 79 Metric tons day 80 Pounds second 81 Pounds minute 82 Pounds hour 83 Pounds day 84 Short tons 2000 pounds minute 85 Short tons 2000 pounds hour 86 Short tons 2000 pounds day 87 Long tons 2240 pounds hour 88 Long tons 2240 pounds day 253 Special 13 Live Sensor R O System FL 4 Any positive 0 1 00 Current Temperature value Temperature floating point re
54. hly Total Number of Dump Cycle 35 Monthly Total Accumulated Volume Revised August 2015 Access R O R W R O R O R W R W R O R W System or User Update System System System System System System System System Data Type UINT16 FL UINT16 UINT16 FL FL UINT32 FL Length 2 Range 0 40 253 Any positive floating point number 0 60 253 0 65536 Any positive floating point number Any positive floating point number 0 4294967295 Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Volume Total Units 0 Unknown 40 U S gallons 41 Liters 42 Imperial gallons 43 Cubic Meters 46 Barrels 42 U S gallons 112 Cubic feet 253 Special The mass accumulated in the current contract day Mass Total units are determined based on the configuration of the meter Mass Total Units 0 Unknown 60 Grams 61 Kilograms 62 Metric tons 63 Pounds 64 Short tons 2000 pounds 65 Long tons 2240 pounds 253 Special The number of dump cycles that have occurred in the previous contract day The volume accumulated in the previous contract day Volume units are determined based on the configuration of the meter The mass accumulated in the previous contract day Mass units are determined based
55. imeout 5 Invalid CRC 6 Invalid Response Format 7 Slot Register Configuration Failed 8 Slow Poll Mode 9 Reset Totals Failed 10 Incompatible target device firmware version Note Slow poll mode occurs when the module s poll request fails all retries are exhausted and the device is not responding which might occur if the connecting wire has been cut In this case the device automatically slows polling shifting from a once per second poll sequence to a once every 10 seconds poll sequence Once the communication problem is resolved normal polling resumes within 10 seconds The current status of the Coriolis meter based on the primary Coriolis status register 0 No Failure 1 Sensor Failure 7 Meter Status R O System UINT8 1 0 1 0 1 00 Revised August 2015 47 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm Name 8 Volume Low Flow Cutoff 9 Live Volume Flow Rate Live Volume Flow Rate 48 Access R W R O R O System or User Update User System System Data Type FL FL FL Length Range 4 Any floating point number 4 Any positive floating point number 4 Any positive floating point number Default Version 0 1 00 0 1 00 0 1 00 Description of functionality and meaning of values The volume flow rate limit at which the flow rate should be c
56. ion To access this screen 1 Select the Smart Meter Verification tab The Smart Meter Verification screen displays F E ROCLINK 800 Coriolis Setup and Values FB107 arim File Edit View ROC Configure Meter Utilities Tools Window Help o x De Gt Wiha MSTORE B Point Number 3 ECP PYR12 v Meter Tag ECP PVR 12 General Calibration Diagnostics i BR TMR Meter Zero Units Confia Values Current Dump Cycle Dump Cycle Min Max Data PYR Configuration Start Action 3000 Output State 3093 Start with Output Fixed Last Value C Fault Value Start with Continuous Values Stiffness Setpoint 3147 0 04 Status Current Procedure Current State 3001 Stopped Percent Complete 3020 0 Stiffness Abort Inlet 3004 Pass Abort Code 3002 0 Outlet 3005 Pass State at Abort 3003 0 Print Save As Auto Scan 2 Update Close Apply 4 gt RENNE 3 28 Pu Figure 9 Coriolis Setup and Values Smart Meter Verification Tab 2 Review and change as necessary the values in the following fields Field Description Output State Sets the output state of the Smart Meter during the verification procedure Default is Last Value 22 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Stiffness Setpoint Start Action Current State Percent Complete Inlet Outlet Abort Cod
57. ion tab These read only fields show in percent the drive gain value at the moment when the minimum and the maximum density values were recorded during the current and the previous contract day These read only fields show the volume rate at the moment when the minimum and the maximum density values were recorded during the current and the previous contract day Units are configured in the Units Configuration tab Drive Gain Min Max Occurrences Cycle Start Time Cycle End Time Time of Occurrence Min Max Drive Gain Value Average Drive Gain These read only fields show the start time of the dump cycle in which the minimum and the maximum drive gain values were recorded during the current and the previous contract day These read only fields show the end time of the dump cycle in which the minimum and the maximum drive gain values were recorded during the current and the previous contract day These read only fields show the time at which the minimum and the maximum drive gain values were recorded during the current and the previous contract day These read only fields show in percent the minimum and the maximum drive gain values recorded during the current and the previous contract day These read only fields show in percent the average drive gain values recorded during the current and the previous contract day 39 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 1
58. ion Tracking Sheet August 2015 This manual may be revised periodically to incorporate new or updated information The revision date of each page appears at the bottom of the page opposite the page number A change in revision date to any page also changes the date of the manual that appears on the front cover Listed below is the revision date of each page if applicable Page Revision All pages Aug 2015 All pages May 2015 Initial release Feb 2014 ii Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter 1 Introduction 1 1 1 Scope and Organization ceccccecccccececeeneeeeeeeeceaeeeeaaesseneeceaaeeeeaaesgeneeceaeeesaaesseaeeseeeeesaeeeeaaeeseneesaas 1 1 2 Product OVE W caeai ted uli Aled eee AL aaa ae i tel ar a 2 1 3 Program Require ment s c setvete sects fet aurea ca edges eNA Naa a eee abode een 3 Chapter 2 Installation 5 2 1 Installing the Module rases aue cent iatueds sauces ag dee dy sald eg eke Gildas dy ald eg teed alg heed abet 5 2 2 Wiring the Module cis Acie r Minne thie atest Sickie ed eth Se dap eta 5 Chapter 3 Configuration 9 3 1 Coriolis Setup and Values Sree Mariin eia tamaaa aiena Ear na eaaa aa er aa A a rE AA ar a naat 10 3 1 1 Coriolis Setup and Values General Tab 0 cccccseseceeeeeceeeeeeeaeeeeaeeeseeeesaeeeeeeeneees 13 3 1 2 Coriolis Setup and Values Calibration Tab ccccccceeceseceeeeee
59. itive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 Any positive floating point number Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Version 1 00 1 00 1 00 Description of functionality and meaning of values Current Reverse Volume Flow Rate retrieved from the meter Volume Rate units are determined based on the configuration of the meter Current Reverse Mass Flow Rate retrieved from the meter Mass Rate units are determined based on the configuration of the meter Enables disables the meter correction for the effect of pressure on the mass flow and density This feature requires the external pressure parameter 161 to be populated as well as the pressure correction factors parameters 162 and 163 0 Disabled 1 Enabled The value of the calculated water cut of the oil water mixture at line flowing conditions The value of the calculated water cut of the oil water mixture at reference base conditions The volume flowrate of the water at line flowing conditions The volume flowrate of the water at reference base conditions The volume flowrate of the oil at line flowing conditions The volume flowrate of the oil at reference base conditions The volume accumulation of the water at line flowing conditions The volume accumulation of the water at reference base conditions Revised Aug
60. l Previous Mass Total Access R W R W R O R O R O R O R O R O R O R O System or User Update User and System User and System System System System System System System System System Data Type UINT8 UINT8 FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT Range 0 1 0 1 Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Reset all communication statistics The value of this parameter returns to 0 once the reset process is complete 0 Disabled 1 Reset Stats Reset all totals Current Today Yesterday and Monthly that are stored in the module The Minimum and Maximum values are also reset 0 Disabled 1 Reset Totals The total volume that the meter has recorded while not in a dump cycle for the current contract day The total mass that the meter has recorded while not in a dump cycle for the current contract day The total volume that the meter has recorded while not in a dump cycle for the previous contract day The total
61. le keeps track of the total volume and mass accumulated during a dump cycle and updates the volume and mass totals once the dump cycle has ended The maximum and minimum density and drive gain values that occurred during the dump cycle are also determined The module uses the contract hour you define using ROCLINK 800 to determine when a new contract day has begun The module stores the maximum and minimum density and drive gain values the number of dump cycles and the volume and mass accumulators for the current and previous contract days When a new contract day is reached the module saves the values for the current contract day as the previous day values and then resets the current day values The module also records monthly totals for volume mass and the number of dump cycles The module zeroes totals at the beginning of a new month which occurs on the contract hour of the first day of a new month Note The totals shown on the Values tab are based on the specified contract hour These totals are independent from the Force End of Day selection ROC gt Information and are not updated when you perform a Force End of Day The continuous mode is designed to measure gas or liquid flow when the flow is not coming from a separator monitoring system In this mode the module continuously requests data from the meters retrieving and saving values for Total Volume for Today Yesterday Total Volume Yesterday s Monthly and the accumulated va
62. low 1 Density OOL Bit 6 Timeout 0 Disabled 1 Enabled Smart Meter Verification Stiffness Setpoint For TBR the Drive Gain percentage above which TBR triggers For TMR the Drive Gain percentage above which TMR triggers Flow rate internal damping seconds Mass Flow Cutoff Density Calibration Point 1 D1 71 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 72 Parm 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 Name Density Calibration Point 2 D2 Tube Period D1 K1 Tube Period D2 K2 Density Temperature Correction DT Density Flow Correction FD Slug Flow High Density Limit g cc Slug Flow Low Density Limit g cc Sensor High Mass Flow Limit Sensor High Volume Flow Limit Device Type Manufacturer ID External temperature input value External pressure input value Pressure correction factor for flow Pressure correction factor for density Access R W R W R W R W R W R W R W R W R W R O R O R W R W R W R W System or User Update User and System User and System User and System User and System User and System User and System User and System System System System System User and System User and System User and System User and System Data Type FLOAT
63. low rate When used with gas meter runs on the ROC800 ROC800L or FB107 use this value as the flow rate input This read only field shows the mixture s unremediated accumulated mass total This read only field shows the mixture s remediated accumulated mass total When used with gas meter runs on the ROC800 ROC800L or FB107 use this value as the accumulator input 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 5 to configure the Meter Zero tab Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 6 Coriolis Setup and Values Meter Zero Note Before you activate the zeroing process shut off the meter s flow and block the meter with valves to isolate any pulsations from the line Refer to the appropriate Micro Motion calibration procedures Zeroing the meter establishes a baseline for process measurement by analyzing the sensor s output when there is no flow through the sensor tubes Use this screen to perform the meter zero process for the selected Coriolis meter To access this screen 1 Select the Meter Zero tab The Meter Zero screen displays ROCLINK 800 Coriolis Setup and Values FB107 balba File Edit View ROC Configure Meter Utilities Tools Window Help ea Ot Yow iS 4 OM Be Point Number 2 ECPTMR1 gt Meter Tag JECPTMR 1 General Calibration Diagnostics Smart Meter
64. lue since the last reset The module retrieves and saves mass values for the same periods Note In case of a communications failure the module is set to hold last value 1 3 Program Requirements Revised August 2015 The Micro Motion Coriolis Interface module is compatible with version 1 70 or greater of the FB107 firmware with version 3 61 or greater of the ROC800 firmware with version 1 41 or greater of the ROC800L firmware and with version 2 40 or greater of the ROCLINK 800 configuration software Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 If used in conjunction with user programs the Micro Motion Coriolis Interface module works with version 1 02 or greater of the Linear Meter Flow Calculation program The Coriolis Interface module supports the following firmware versions of these core processors and transmitters Device Type Firmware Version 700 Core Processors 3 2 or greater 800 Enhanced Core Processor 3 9 or greater 1500 Transmitter 6 6 or greater 1700 Transmitter 6 6 or greater 2500 Transmitter 6 6 or greater 2700 Transmitter 6 6 or greater 3000 Series Transmitter 8 2 or greater Note The comm settings for the Interface module are fixed at a baud rate of 19 200 no parity 8 data bits and 1 stop bit You cannot change these values the meter s core processor detects this protocol and matches them automatically However if you
65. mass that the meter has recorded while not in a dump cycle for the previous contract day Volume total based on the volume total read from the double precision accumulator in the Coriolis meter Previous volume total based on the volume total read from the double precision accumulator in the Coriolis meter during the previous second Mass total based on the mass total read from the double precision accumulator in the Coriolis meter Previous mass total based on the mass total read from the double precision accumulator in the Coriolis meter during the previous second Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 111 112 113 114 115 116 117 118 119 120 Name Licensed Features SMV Start Flow Type TBR Enable Disable Current Pressure Compensation Effect On Flow Current Pressure Compensation Effect On Density Duration of Last TBR Zero Standard Deviation Left pickoff voltage volts Right pickoff voltage volts Revised August 2015 Access R O R W R W R W R O R O R O R O R O R O System or User A Update YP System UINT8 User and UINT8 System User and UINT8 System System UINT8 System FLOAT System FLOAT System FLOAT System FLOAT System FLOAT System FLOAT Length Range 0 2 0 1 Oor1 Any po
66. mmunications port on the module using between 16 and 24 AWG wiring Figure I and Figure 2 show example wiring between the module and several meters Note Coriolis meters must be externally powered Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 W gt 24V EXTERNAL POWER DOODO DOC0947B 24V EXTERNAL POWER A B 24V EXTERNAL POWER RDOUS AREA L HAZARDOUS APPLICATION 24V EXTERNAL POWER Figure 1 Module Wiring NON HAZARDOUS APPLICATION Micro Motion 700 800 Coriolis Meter with Internal Core Processor Micro Motion MVD Direct Connect Safety Barrier Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Revised August 2015 A Sh O O O Figure 2 Module Wiring Micro Motion 700 800 Coriolis Meter with Internal Core Processor Micro Motion 1700 single variable 2700 multi variable or 3000 Series transmitter suited for use in a hazardous area Cc Micro Motion 1500 single variable 2500 multi variable or 3000 Series transmitter sui
67. n Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System sol Name Access or User AA Update yp 164 Flow Calibration R W User and FLOAT Pressure System 165 LD Optimization R W User and UINT16 System 166 Flow Direction Setup R W User and UINT8 System Revised August 2015 Length Range Any positive floating point number 0 1 0 5 Default 0 0 Version 1 00 1 00 1 00 Description of functionality and meaning of values Flow calibration pressure LD Optimization for liquid hydrocarbons Should not be enabled for gas measurement 0 Disabled 1 Enabled The flow direction configured for the meter 0 Forward Only 1 Reverse Only 2 Bi Directional 3 Absolute Value 4 Negate Forward Only 5 Negate Bi Directional 73 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System PAN Name Access or User ata Length Range Update ype 167 Pressure Units R W User and UINT16 1 0 239 System 168 Flow Calibration R W User and AC 20 ASCII Factor FCF System 169 Temperature R W User and AC 20 ASCII Calibration Factor System 170 Volume Accumulated R O System FLOAT 4 Any positive floating point number 74 Default 0 Version 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Pr
68. nd Smart Meter Verification provided these functions are activated on the Coriolis meter s core processor The module operates in either continuous mode during which flow never ceases or dump cycle mode during which should flow drop below a minimum setpoint the module stops accumulating flow counts cycles and stores cycle specific data Using Modbus the module continuously requests data from the meters When it receives new data the module compares the volume flow rate from the meter to the user defined volume low flow cutoff value and performs the following actions Ifthe value of the volume flow rate register is zero the parameters in the module s point type corresponding to the values 2 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 received from the meter are updated and no further processing of the data is performed If the value is greater than zero but less than the volume low flow cutoff value the module considers the volume and mass accumulated to be trickle flow The accumulated volume and mass values are added to both the daily totals parameters and the separate trickle flow totals Ifthe value of volume flow rate is greater than the module s low flow cutoff value the module considers the values received during the period at which the volume flow rate remains above the volume low flow cutoff value to be part of a dump cycle The modu
69. nds The end time of the dump cycle in which the minimum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds Revised August 2015 59 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 60 Parm 72 73 74 75 76 77 Name Today s Minimum Drive Gain Time of Occurrence Today s Minimum Drive Gain Density at Today s Minimum Drive Gain Volume Rate at Today s Minimum Drive Gain Yesterday s Maximum Drive Gain Cycle Start Time Yesterday s Maximum Drive Gain Cycle End Time Access R O R O R O R O R O R O System or User Update System System System System System System Data Type UINT32 FL FL FL UINT32 UINT32 Length Range 0 235959 Any positive floating point number Any positive floating point number Any positive floating point number 0 235959 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The time at which the minimum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The minimum drive gain value recorded during the current contract day Drive gain units are percent
70. ned by the associated density unit selection parameter 16 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 This page is intentionally left blank Revised August 2015 79 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 For Customer Service and Technical Support Dial 1 800 537 9313 Headquarters Emerson Process Management Remote Automation Solutions 6005 Rogerdale Road Houston TX 77072 U S A T 1 281 879 2699 F 1 281 988 4445 www EmersonProcess com Remote Europe Emerson Process Management Remote Automation Solutions Unit 8 Waterfront Business Park Dudley Road Brierley Hill 2014 2015 Remote Automation Solutions a business unit of Emerson Process Dudley UK DY5 1LX Management All rights reserved T 44 1384 487200 F 44 1384 487258 Remote Automation Solutions a business unit of Emerson Process Management shall not be www EmersonProcess com Remote liable for technical or editorial errors in this manual or omissions from this manual REMOTE North American Latin America AUTOMATION SOLUTIONS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE Emerson Process Management IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH Remote Automation Solutions RESPECT TO THIS MANUAL AND IN NO EVENT SHALL REMOTE AUTOMATION SOLUTIONS BE 6005 Rogerdale Road LIABLE FOR ANY INCIDENTAL PUNI
71. nits Pressure Units Mass Total Units Volume Total Units Description Sets the unit of mass flow rate for the selected meter Click wv to display all defined options Note If you change this value the module resets and clears all totals No conversion of units occurs Sets the unit of temperature for the selected meter Click wv to display all defined options Sets the unit of density for the selected meter Click w to display all defined options Sets the unit of pressure for the selected meter Click w to display all defined options This read only field shows the Mass Total Units of the selected meter The units are determined from Mass units selected above without a time base Note that units differ when measuring liquids as compared to gas Select units accordingly This read only field shows the Volume Total Units of the Coriolis meter The Volume units are determined from the selections above without a time base 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 8 to configure the Values tab Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 8 Coriolis Setup and Values Values Use this screen to view the total accumulated volume and mass values for the selected Coriolis meter Note The Values screen shown in Figure 13 is a composite It is only an example for documentation purposes and would
72. nsity at Today s Maximum Drive Gain 69 Volume Rate at Today s Maximum Drive Gain 70 Today s Minimum Drive Gain Cycle Start Time 71 Today s Minimum Drive Gain Cycle End Time Access R O R O R O R O R O R O System or User Update System System System System System System Data Type FL FL FL FL UINT32 UINT32 Length Range Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number 0 235959 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The maximum drive gain value recorded during the current contract day Drive gain units are percent The average density value during active dump cycles recorded during the current contract day Drive gain units are percent The density value recorded when the maximum drive gain value for the current contract day occurred Density units are determined based on the configuration of the meter The volume rate recorded when the maximum drive gain value for the current contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the minimum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seco
73. nt Number i ECPTBR2 Meter Tag ECP TBR 2 General Calibration Diagnostics Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PVR TBR Liquid Z TMR Gas Mode Status 433 TMR Gas Enabled Status Inactive Pre Mist Ave Period 619 10 seconds C Disabled Duration of Last 989 20 seconds Post Mist Adj Delay 620 6 seconds Drive Gain 291 6 463333 x Drive Gain Threshold 617 5 0 Flowrates TBR Liquid Control 624 Mass Flowrate Unremediated 247 0 0 Ibs hour Timeout Mass Flowrate Remediated 973 0 0 Ibshour Enabled Timeout Period 619 10 seconds Disabled Totals A 7 7 Mass Total U diated 259 32 Ib Initial Action Drive Gain Averaging r Apply to Flow saen Teste SES 5 Hold Last Value One Second Cc Yes Mass Total Remediated 975 32 52808 Ibs Set TBR Active Status Only C Four Seconds No Timeout Action Timeout Alarm Type Apply to Density Show Actual Values Slug Flow Yes C Alarm C Density OOL C No Drive Gain Threshold 617 50 0 Lookback Period 620 5 seconds Print Save As Auto Sean 7370 3 Close Apply gt ERNE 10 35AM Figure 10 Coriolis Setup and Values TBR TMR Tab 2 Review and change as necessary the values in the following 24 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Revised August
74. oating point number Any positive floating point number 0 235959 0 235959 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The minimum density value recorded during the previous contract day Density units are determined based on the configuration of the meter The drive gain value recorded when the minimum density value for the previous contract day occurred Drive gain units are percent The volume rate recorded when the minimum density value for the previous contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the maximum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The end time of the dump cycle in which the maximum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The time at which the maximum drive gain value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm Name 66 Today s Maximum Drive Gain 67 Today s Average Drive Gain 68 De
75. on the configuration of the meter The total number of dump cycles that have occurred during the current month The volume accumulated in the current month Volume units are determined based on the configuration of the meter 53 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 54 Parm 36 37 38 39 40 41 Name Monthly Total Accumulated Mass Today s Maximum Density Cycle Start Time Today s Maximum Density Cycle End Time Today s Maximum Density Time of Occurrence Today s Maximum Density Today s Average Density Access R W R O R O R O R O R O System or User Update System System System System System System Data Type FL UINT32 UINT32 UINT32 FL FL Length Range 4 Any positive floating point number 4 0 235959 4 0 235959 4 0 235959 4 Any positive floating point number 4 Any positive floating point number Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The mass accumulated in the current month Mass units are determined based on the configuration of the meter The start time of the dump cycle in which the maximum density value for the current contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds
76. onfiguration Note For archive purposes you should also save this configuration to your PC s hard drive or a removable media such as a flash drive using the File gt Save Configuration option on the ROCLINK 800 menu bar Bg Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter 4 Reference Materials This section provides tables of information on the point types the MMI Coriolis Interface module uses Point Type 65 for the FB107 or Point Type 244 for the ROC800 ROC800L Revised August 2015 45 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 4 1 Point Type 65 244 Micro Motion Coriolis Interface Module Point type 65 for FB107 or point type 244 for ROC800 ROC800L contains the parameters for configuring the Coriolis Interface Application module The FB107 supports four logicals of this point type corresponding to the four meter runs the FB107 supports the ROC800 ROC800L supports six logicals corresponding to the six meter runs the ROC800 ROC800L supports Point Type 65 244 Coriolis Interface Application Module Parm 0 Point Tag ID Name 1 Coriolis Modbus Address 2 Polling Enable 3 Number of Retries Poll Timeout 5 Actual Poll Period 46 Access R W R W R W R W R W R O System or User Update User User User User User System Data Type AC UINT8
77. onsidered as no flow This value allows the module to identify the beginning and end of dump cycles Volume accumulated below this cutoff but above the Coriolis meter s low flow cutoff is considered to be trickle flow For TBR the current volume flow rate retrieved from the meter Rate units are determined based on the configuration of the meter For TMR the remediated volume flow rate retrieved from the meter Rate units are determined based on the configuration of the meter Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm System Data Name Access or User Length Range Default Version U Type pdate 10 Volume Flow Rate R W System UINT16 2 0 15 253 0 1 00 Units 11 Live Mass Flow Rate R O System FL 4 Any positive 0 1 00 floating point number Live Mass Flow Rate R O System FL 4 Any positive 0 1 00 floating point number Revised August 2015 Description of functionality and meaning of values Volume Flow Rate Units 0 Unknown 15 Cubic feet minute 16 Gallons minute 17 Liters minute 18 Imperial gallons minute 19 Cubic meters hour 22 Gallons second 23 Million U S gallons day 24 Liters second 25 Millions liters day 26 Cubic feet second 27 Cubic feet day 28 Cubic meters second 29 Cubic meters day 30 Imperial gallons hour 31 Imperial gallons day 130 Cubic
78. otion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Total Volume Total Mass Accumulated Volume During Trickle Flow 34 Description These read only fields show the volumes accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in the Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These fields display only if you select Dump Cycle as the Meter Mode on the General tab These read only fields show the mass accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in the Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These
79. read only field shows whether the temperature for the meter s RTD is out of range Valid values are Yes and No This read only field shows whether the temperature for the line s RTD is out of range Valid values are Yes and No This read only field shows whether the meter s reported density is outside of standard API ranges Valid values are Yes and No This read only field shows whether the meter s temperature is outside of standard API ranges Valid values are Yes and No This read only field shows whether the RAM diagnostic procedure initiated during a power reset has failed Valid values are Yes and No This read only field shows whether the EEPROM Checksum procedure initiated during a power reset has failed Valid values are Yes and No This read only field shows whether the drive is outside of its proscribed range Valid values are Yes and No This read only field shows whether the density is outside of standard limits Valid values are Yes and No Communication Statistics Number Requests Sent to Meter Number of Good Responses Number of Response Timeouts Number of Error Reponses Reset Comm Stats Meter Information Meter Model Type 20 This read only field shows the total number of Modbus requests the module has sent to the selected meter This read only field shows the total number of valid Modbus responses the module has received from the selected meter This read only field shows
80. rred 16 SMV Completed 0 15 SMV Aborted before completion Smart Meter Verification Inlet Stiffness 0 In Limits gt 0 Out of Limits Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 127 SMV Outlet Stiffness Name 128 Meter Model Type 129 SMV Percent Complete 130 Raw tube frequency Hz 131 LPO amplitude volts 132 RPO amplitude volts 133 Board temperature C 134 Input voltage volts 135 TBR status 136 Status Word 1 Access R O R O R O R O R O R O R O R O R O R O System or User Update System System System System System System System System System System Data Type UINT16 UINT8 UINT16 FLOAT FLOAT FLOAT FLOAT FLOAT UINT8 UINT16 Length 2 Range 0 65535 0 1 0 100 Any floating point number Any floating point number Any floating point number Any floating point number Any floating point number Oor1 0 65535 Default 0 0 0 0 0 0 0 0 0 0 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Smart Meter Verification Outlet Stiffness 0 In Limits gt 0 Out of Limits Sensor Type 0 Curved Tube 1 Straight Tube Percentage of the current SMV procedure that is complete Ra
81. s read only field shows the period of time in seconds between meter polls This read only field shows the current communication status with the selected meter Valid values are Communication Disabled Communicating Configuring Slot Registers Retrying Response Timeout Invalid CRC Invalid Response Format and Slot Register Configuration Failed Slow Poll Mode Reset Totals Failed and Incompatible Target Device Note Slow poll mode occurs when the module s poll request fails all retries are exhausted and the device is not responding which might occur if the connecting wire has been cult In this case the device automatically slows polling shifting from a once per second poll sequence to a once every 10 seconds poll sequence Once the communication problem is resolved normal polling resumes within 10 seconds Enables polling between the module and the selected Coriolis meter Valid values are Enabled and Disabled The default is Disabled Defines how the module handles flow Valid values are Continuous Flow and Dump Cycle The default is Continuous Flow For liquid flow measurement use Dump Cycle mode For gas flow measurement use Continuous mode Sets the Flow Direction configured for the meter The default is Forward Only Note Bi Directional is available only when using the Continuous Flow meter mode Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and
82. sed August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter 1 Introduction A Caution When using inputs that are not resident in the flow computer or RTU that is are provided by a communication mechanism for control ensure that a supervisory system or mechanical safety equipment is in place to provide proper function While communication errors are noted in the device s alarm log be aware that you may need to perform actions to prevent field issues This chapter describes the structure of this manual and presents an overview of the Micro Motion Coriolis Interface module for the FloBoss 107 Flow Manager FB107 and the ROC800 Series Remote Operations Controller both the ROC800 and the ROC800L The Coriolis Interface module provides all of the functions necessary to communicate with the core processor of a Micro Motion Coriolis meter and includes an onboard RS 485 communications port that enables communications between the module and the Coriolis meter without using one of the communications ports of the FB107 or the ROC800 ROC800L Additionally in simple allocation situations which do not require custody transfer one Coriolis Interface module which connects with up to six Coriolis meters can take the place of transmitters In situations requiring custody transfer and the pulse counts transmitters provide connecting the Coriolis Interface module to the transmitter pro
83. ser Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System PAON Name Access or User z AR Length Range Update YP 121 Live zero mass flow R O System FLOAT 4 Any floating point number 122 SMV Start Mode R W Userand UINT16 2 1 6 System 123 SMV State R O System UINT16 2 0 255 124 SMV Abort Code R O System UINT16 2 0 15 125 SMV State at Abort R O System UINT16 2 0 255 126 SMV Inlet Stiffness R O System UINT16 2 0 65535 66 Default 0 0 1 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Live zero mass flow Value sent to Meter to initiate the Smart Meter Verification Process 1 Start with Output Fixed 6 Start with Continuous Values Smart Meter Verification State 0 Not Running gt 0 Running Abort Error Code for the previous SMV Procedure Valid values are 0 No Error 1 User Initiated Abort 2 Drive Settle Time error 3 Frequency Drift 4 Drive voltage too high 5 Drive current too high unstable drive 6 Drive current erratic unstable drive 7 General drive error 8 Delta T erratic 9 Delta T too high 10 State running 11 State complete 12 Meter verification data error 13 Unit has not been calibrated on air 14 Unit has not been calibrated on water 15 Meter verification configuration items are not correct Smart Meter Verification State When Abort Occu
84. sitive floating point number Any positive floating point number Any positive floating point number Any floating point number Any floating point number Any floating point number Default 0 0 0 0 0 0 0 0 0 0 0 0 0 Version 1 10 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Indicates the licensed features Valid values are 0 SMV License 1 PVR License 2 TBR License 3 TMR License Sends the SMV Start Mode to the meter to begin the SMV process or aborts the process if it is already started 0 No Action 1 Start SMV by sending the SMV Start Mode to the meter or send a 0 to the meter to abort the SMV process 2 Start or Abort in progress Defines how the module handles flow 0 Continuous Flow Mode 1 Dump Cycle Flow Mode Indicates if the TBR Transient Bubble Remediation capabilities of the meter have been enabled or disabled 0 TBR Disabled 1 TBR Enabled Current pressure compensation effect on flow This value is not populated when a transmitter is used Current pressure compensation effect on density This value is not populated when a transmitter is used Amount of time in seconds TBR was active the last time it was executed Zero Standard Deviation Left pickoff voltage volts Right pickoff voltage volts 65 Micro Motion Coriolis Interface Module U
85. t bubbles The mass accumulation of the oil water mixture remediated for any transient bubbles The combined oil and water volume total remediated for any transient bubbles The temperature at which the corrected flowrates and totals have been corrected This is typically 60 deg F or 15 deg C The units are determined by the associated temperature unit selected parameter 14 The density of dry oil at base conditions This is used to calculate the water cut and therefore determine the percentage of oil versus water in the stream This value is obtained by use of a petroleum analysis laboratory or an external calculation routine The units expected for the value are determined by the associated density unit selection parameter 16 77 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System oh Name Access or User ses Length Range Update 200 Water Base Density R W User FLOAT 4 Any positive floating point number 78 Default 0 0 Version 1 10 Description of functionality and meaning of values The density of produced water at base conditions This is used to calculate the water cut and therefore determine the percentage of oil versus water in the stream This value is obtained by use of a petroleum analysis laboratory or an external calculation routine The units expected for the value are determi
86. tatus of the meter zero procedure 0 Complete 1 In Progress 2 Zeroing failed zero too low 3 Zeroing failed zero too high 4 Zeroing failed zero too noisy The value of the meter zero offset previous to the last initiation of the Start Meter Zero cycle The value of the meter zero offset as determined by the meter zero procedure The Volume Flow Cutoff currently being used by the meter The Volume Flow Meter Factor currently being used by the meter The Mass Flow Meter Factor currently being used by the meter The Density Meter Factor currently being used by the meter The total number of Modbus requests sent to the Coriolis meter The total number of valid Modbus responses received from the Coriolis meter The total number of times a response was not received from the Coriolis meter The total number of error Modbus responses received from the Coriolis meter 63 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 64 Parm 101 102 103 104 105 106 107 108 109 110 Name Reset Communication Statistics Reset Totals Today s Total Accumulated Trickle Volume Today s Total Accumulated Trickle Mass Yesterday s Total Accumulated Trickle Volume Yesterday s Total Accumulated Trickle Mass Current Volume Total Previous Volume Total Current Mass Tota
87. ted for used in a non hazardous area D gt For best results all Micro Motion Coriolis meter and transmitters require 24Vdc power The following table outlines the typical power draw for standard Coriolis meter configurations When designing an application consider these power requirements Table 1 Configuration Power Requirements Configuration 24 VDC Current Sensor with Core Processor Only 768 mW 32 mA Sensor with Core Processor amp Barrier 1440 mW 60 mA Sensor with 1500 2500 Transmitter 3432 mW 143 mA Sensor with 1700 2700 Transmitter 6000 mW 250 mA Sensor with 3700 Net Oil Transmitter 7420 mW 309 mA Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 This page is intentionally left blank 8 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter 3 Configuration After you have successfully installed the MMI Coriolis Interface module and wired the meter to the module start ROCLINK 800 and configure the module using the Coriolis Setup and Values screen see Section 3 1 Use the screen and its component tabs to configure communications with the Coriolis meter perform calibration view flow rates and totals and view diagnostic information To ensure that the device recognizes the module you must perform a warm start ROC gt Flags gt Warm Start Note Once the module is installed you can identif
88. the Meter Mode and either Forward Only or Bi Directional as the Flow Direction Mode on the General tab These read only fields show the mass accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in the Today field resets to zero and the last value recorded by the meter becomes the value of the Yesterday Total Volume field Note These fields display only if you select Dump Cycle as the Meter Mode and either Forward Only or Bi Directional as the Flow Direction Mode on the General tab Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Field Description Reverse Total These read only fields show the volumes Volume accumulated in the current contract day Today in the previous contract day Yesterday and in the current month Monthly The value in the Accumulated field provides a running total for all dump cycles is updated after the completion of a dump cycle and during trickle flow and rolls over at 1 000 000 units Configure units using the Units Configuration tab Once the contract day is over the value in th
89. tion Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 2 Saving the Configuration Whenever you modify or change the configuration it is a good practice to save the final configuration to memory To save the configuration 1 Select ROC gt Flags The Flags screen displays Flags Eam Restart Flash Memory Warm Start Save Configuration Clear Cold Start tatus Cold Start amp Clear Alarms E vents agus Cold Start amp Clear Displays Cold Start amp Clear FST s Cold Start amp Clear History Cold Start amp Clear ALL 2 Update Y OK X Cancel Apply Figure 17 Flags screen 2 Click Save Configuration A verification message displays l Q Perform Flash Memory Save Configuration 1 No Figure 18 Perform screen 3 Click Yes to begin the save process The Status field on the Flags screen displays In Progress When the process completes the following message displays Revised August 2015 43 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 ROCLINK 800 gt Flash Memory Save Configuration COMPLETED Flash Configuration bytes free 42576 Figure 19 Save Confirmation 4 Click OK The Status field on the Flags screen displays Completed 5 Click Update on the Flags screen This completes the process of saving your new c
90. trieved from the meter number Temperature units are determined based on the configuration of the meter 14 Temperature Units R W System UINT16 2 0 32 35 0 1 00 Temperature Units 0 Unknown 32 Degrees C 33 Degrees Fahrenheit 34 Degrees Rankine 35 Kelvin 50 Revised August 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module System DAN Name Access or User z n Update yp 15 Live Flowing Density R O System FL 16 Density Units R W System UINT16 17 Live Drive Gain R O System FL 18 Dump Cycle Status R O System UINT8 19 Current Dump Cycle R O System UINT32 Start Time 20 Current Dump Cycle R O System UINT32 End Time Revised August 2015 Length Range Any positive floating point number 0 90 104 Any positive floating point number 0 1 0 235959 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 Description of functionality and meaning of values Current Density value retrieved from the meter Density units are determined based on the configuration of the meter Density Units 0 Unknown 90 Specific gravity units 91 Grams cubic centimeter 92 Kilograms cubic meter 93 Pounds gallon 94 Pounds cubic foot 95 Grams milliliter 96 Kilograms liter 97 Grams liter 98 Pounds cubic inch 99 Short tons 2000 pounds cubic yard 104 Degrees API Current Drive Gain value
91. ues Diagnostics Tab Use this screen to view the meter status and diagnostic messages for the selected Coriolis meter To access this screen 1 Select the Diagnostics tab The Diagnostic screen displays ROCLNK 800 Coriolis Setup and Values FB107 File Edit View ROC Configure Meter Utilities Tools Window Help Dw el Gt E HUM SONE Point Number 1 ECP TBR 2 X Meter Tag ECP TBR 2 General Calibration f Smart Meter Verification TBR TMR Meter Zero Units Config Values Current Dump Cycle Dump Cycle Min Max Data PYR Meter Status 419 Sensor Failure NO Data Loss Possible NO Flow Direction FORWARD Meter RTD Temp Out of Range NO Line RTD Temp Out of Range NO Curr Pressure Compensation Effect on Flow 991 Curr Pressure Compensation Effect on Dens 993 Density Outside Standard Range NO Temp Outside Standard Range NO RAM Diagnostic Failure NO EEPROM Checksum Failure NO Drive Overrange NO Density Outside of Limits NO joo a 24 9203 fizg9e992 v a Board Temperature 383 Input Voltage 385 Live Zero 293 Zero Standard Deviation 231 Communication Statistics Number Requests Sent to Meter Number of Good Responses Device Type 120 700 Core Processor 800 Enhanced Core Processor 0 0 134 4181 Hz 0 460457 Y Raw Tube Frequency 285 Left Pickoff Voltage 287 Revised August 2015 1500 Transmitter 1700 Transmitter 2500 Transmitter 2700 Tr
92. umber of seconds in the timeout period has passed and the TBR event is still active Default is Show Actual Values Determines the type of alarm that the module triggers in the event of TBR timeout Valid values are Slug Flow or Density OOL out of limits Default is Slug Flow Note You must also set the Timeout Action option to Alarm Determines if the TBR event modifies the density calculations Default is Yes Sets the Drive Gain percentage above which the system initiates a TBR event The default is 1 8 25 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 26 Field Lookback Period TMR Gas Pre Mist Ave Period Post Mist Adj Delay Drive Gain Threshold Mass Flowrate Unremediated Mass Flowrate Remediated Mass Total Unremediated Mass Total Remediated Description Sets the number of seconds back in time from which the program calculates the last measured value LMV for density Valid values range from 5 to 30 seconds Default is 0 Defines in seconds the application goes back in time to determine the density to use in TMR remediation Defines in seconds how long the application waits before beginning density adjustments due to TMR Sets the Drive Gain percentage that triggers a TMR event The default is 1 8 This read only field shows the mixture s unremediated mass flow rate This read only field shows the mixture s remediated mass f
93. ust 2015 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm 192 193 194 195 196 197 198 199 Name Net Oil Total Uncorrected Net Oil Total Correcte Mix Mass Total Unremediated Mass Flowrate Remediated Mass Total Remediated Volume Total Remediated Reference Temp Oil Base Density Revised August 2015 Access R W R W R W R W R W R W R W R W System or User Update System System System System System System User User Data Type FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT Length 4 Range Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Any positive floating point number Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Version 1 10 1 10 Description of functionality and meaning of values The volume accumulation of the oil at line flowing conditions The volume accumulation of the oil at reference base conditions The mass accumulation of the oil water mixture as directly measured by the meter The mass flowrate of the oil water mixture remediated for any transien
94. vides extensive real time analysis of flow data APP 485 application modules for the ROC800 ROC800L and FB107 including the Micro Motion Coriolis Interface module streamline the installation process by automatically installing all point types and screens that are part of the application APP 485 modules can house a variety of applications for further information about additional APP 485 modules contact your sales representative 1 1 Scope and Organization Revised August 2015 This document serves as the user manual for the Micro Motion Coriolis Interface Module which is intended for use in a FB107 or ROC800 ROC800L This manual describes how to install and configure the Coriolis Interface module referred to as the Coriolis Interface or the module throughout the rest of this manual You access and configure this module using ROCLINK 800 configuration software loaded on a personal computer running Microsoft Windows 2000 with Service Pack 2 Windows XP Windows Vista or Windows 7 The sections in this manual provide information in a sequence appropriate for first time users Once you become familiar with the procedures and the software the manual becomes a reference tool This manual has the following major sections Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Chapter l Introduction Chapter 2 Installation Chapter 3 Configuration Chapter 4
95. w tube frequency Hz LPO amplitude volts RPO amplitude volts Board temperature C Input voltage volts Set by METER if TBR option is activated to indicate current status Status Word 1 Bit 0 Core EEPROM Checksum Error Bit 1 Core RAM Test Error Bit 2 Real Time Interrup Failure Bit 3 Sensor Failure Bit 4 Temperature Sensor Out of Range Bit 5 Calibration Failure Bit 6 Other Failure Bit 7 Transmitter Initializing Warming Up Bit 8 PV Out of Limits Bit 9 Non PV Out of Limits Bit 10 Simulation Mode Active Bit 11 Undefined Bit 12 Watchdog Error Bit 13 Cold Start Bit 14 Transmitter Configuration Changed Bit 15 Fault Revised August 2015 67 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module Parm System Data a Name Access or User Length Range Default Version Type Update 137 Status Word 2 R O System UINT16 2 0 65535 0 1 00 68 Description of functionality and meaning of values Status Word 2 Bit 0 Primary mA Output Saturated Bit 1 Secondary mA Output Saturated Bit 2 Primary mA Output Fixed Bit 3 Secondary mA Output Fixed Bit 4 Density Outside Limits Bit 5 Drive Over Range Bit 6 PIC Daughterboard Communication Failure Bit 7 External Input Failure Bit 8 Core EEPROM Checksum Error Bit 9 Core RAM Error Bit 10 Sensor Not Respon
96. y a ROC800 Coriolis Interface module from the label on the face of the module On the FB107 the label is on the side of the physical case Using ROCLINK 800 click the APP 485 module shown in the ROCLINK 800 graphic display A label appears identifying the module see Figures 3 and 4 Figure 3 Micro Motion Coriolis Interface Module FB107 Revised August 2015 9 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 3 1 10 MAR AS ee os hal Be Re ay o s car a Kae C i 2 4 s 5h a s A s 9 Shed eho be Te Sia eo 634620 93 Li DoCeees ke ve a Figure 4 Micro Motion Coriolis Interface Module ROCS amp 00 You must configure the module before you can establish communications with the Coriolis meter To configure the module after successfully installing and wiring the module proceed through the screens as shown in this chapter Coriolis Setup and Values Screen For the ROC800 For the FB107 Note The Coriolis Setup and Values screen is identical for both the FB 107 and ROC800 ROC800L Use this screen to configure communications with the Coriolis meter perform meter calibration view flow rates and totals and view diagnostic information To access this screen 1 From the Directory Tree double click User Display Double click Display 66 Coriolis Setup and Values The Coriolis Setup and Values screen displays
97. y positive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 Any positive floating point number 4 0 235959 Default 0 Version 1 00 1 00 1 00 1 00 1 00 1 00 Description of functionality and meaning of values The time at which the maximum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds The maximum drive gain value recorded during the previous contract day Drive gain units are percent The average drive gain value during active dump cycles recorded during the previous contract day Drive gain units are percent The density value recorded when the maximum drive gain value for the previous contract day occurred Density units are determined based on the configuration of the meter The volume rate recorded when the maximum drive gain value for the previous contract day occurred Volume units are determined based on the configuration of the meter The start time of the dump cycle in which the minimum drive gain value for the previous contract day was recorded Byte 3 Unused Byte 2 Hours Byte 1 Minutes Byte 0 Seconds 61 Micro Motion Coriolis Interface Module User Manual for ROC800 Series and FloBoss 107 Point Type 65 244 Coriolis Interface Application Module 62 Parm 84 85 86 87 88 89 Name Yesterday s Minimum