1. Sunction and filtration of toxic harmful fumes with activated charcoal filters Capacity and productivity Possibility to use racks with different capacities 10 20 30 slides Possibility to perform up to 3 compatible protocols simultaneously data sheet Rev First emission 23 09 2010 Productivity with optimized Hematoxylin Eosin protocol about 110 slides hour in racks of 30 slides carrier capacity Productivity with optimized Papanicolaou protocol about 90 slides hour in rack of 30 slides carrier capacity Possibility to set priority reagent basin for emergencies management STAT Possibility to perform staining runs without covers using to reduce moving times Installation e Benchtop minimum capacity 100 Kg mq leveled base and settable stems e Necessary running water feeding DN 15 with hose nozzle connection pressure min 3 Bar max 6 Bar e Necessary hydraulic dump for stainers DN 15 hose nozzle connection eSupport base minimum dimension 1350Lx650Dx700H mm Maintenance cod 53COLO1 RAFFAELLO BASIC eWeekly and monthly set according to directions written in user manual cod 53COLO02 RAFFAELLO ADVANCED The software and the stainer control electronics integrate FMC Fast Maintenance Check option that checks and manages the periodical maintenance necessary to ensure an high security and qualitative standard CE IVD certificated The software notifies and requires the periodical Maintenance KIT installatio
2. ation of name position or associated basin and cover association during the staining Definition of reagent name by the operator in large or reduced way according to the needs The name defined in the reagent index is available in all performed stainings Every time it is possible to link the basin to the performing protocol step RAFFAELLO saves in the index more reagents than those really used In this way during the protocol change it is possible to start up the staining and confirm the real basins change to obtain an updated situation of the used reagents and stainers Possibility to associate cover presence on the basin according to the reagent volatility features Selectioning the dedicated option the robotized arm of RAFFAELLO automatically will move away the cover before perfoming the staining and after rack moving will put it back Reagents charge and discharge 2 Counting of the performed immersion number for each Started up staining thanks to the Reagent Managing System Reagent exhaustion alarm thresold with acoustic and visual alarm settable for each reagent according to the reagent managing used in your lab Rack immersion counting zeroing in accordance with reagent change in the basin Possibility to check in every time the number of reagent immersions both performed and both to be performed Diapath S p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000
3. atus updating electronic chip For further information concerning RAFFAELLO Staining KIT composition see the relative security and data sheets Indications reported in the current data sheet are indicative of the available KIT range studied for RAFFAELLO Advanced 3 Diapath p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 966417 Faw 39 0363 948 000 yw diapath com infoeidiapath com COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 13485 2003 DIAPATH USING FEATURES EEA E EE 5 RUN Pea Ja a ali EMATOSSILINAE RUNMICROCLEARIN 13 56 eee eee Ce NONE ahii Si ge a Reagents management data sheet Rev First emission 23 09 2010 Staining protocols programming 1 Modern stainer controlled by a software that allows to manage all standard and advanced facilities for histological and cytological stainings Staining protocols saved on the control PC Staining starting up selectioning the protocol and pushing the Start key on the Touch Screen panel Saving of all necessary protocols through the software interface setting in a different way steps number used reagent staining times dropping time cover use and priority reagent basin Possibility to perform up to 3 stainings simultaneously with compatible protocols or using the same reagents Index entering of each stainer and reagent used in the staining protocols Registr
4. data sheet Rev First emission 23 09 2010 DIAPATH se ISO 13485 2003 RAFFAELLO Automatic stainer for histological and cytological samples C Automatic stainer BASIC code 53COL01 Automatic stainer with FMC Fast Maintenance Check ADVANCED code 53COL02 Temporary image of RAFFAELLO automatic stainer General features RAFFAELLO is a compact and user friendly stainer intended for histological section and cytological sample stainings State of art it allows to obtain stainings using the optimized protocols Hematoxylin Eosin and Papanicolaou thanks also to the dedicated reagents set Using OTTIX Shaper and OTTIX Plus it is possible to decrease the necessary reagents quantity and since OTTIX is toxicity free it is also possible to reduce the chemical risk in your lab RAFFAELLO perfoms not only standard and optimized histological and cytological staining protocols but also customized protocols to obtain particular results It allows to perform up to 3 stainings simultaneously with compatible protocols Diapath S p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000 www diapath com info diapath com 1 COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV SO 13485 2003 Facilities e Hematoxylin Eosin stainings e Papanicolaou stainings Slide washing with water automatic charge and flow regulation e Staining with using of covers for reagent basins
5. n The internal electronics checks and manages the right KIT installation excluding the stainer usage in uncertificated conditions and ensuring replaced components authenticity and operator s safety Diapath S p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000 www diapath com info diapath com DIAPATH Mirer Consume dedicated products only for ADVANCED RAFFAELLO cod 53COL02 RAFFAELLO Staining KIT for 1000 H amp E test standard composition e Ottix plus e Ottix shaper e Hematoxylin choice of Carazzi Gill I Gill Il Harris Mayer e Eosin choice of Floxin alcolica alcoholic HB watery watery HB Hematoxylin Eosin RAFFAELLO Staining KIT for 1000 PAPANICOLAOU test standard composition e Ottix plus e Ottix shaper e Hematoxylin choice of Gill II Harris cata sneet Rev First emission 23 09 2010 RAFFAEL N Terini K e Stainers choice of EA31 EA50 EA50 Ultra Bright EA65 Ultra Bright RAFFAELLO Mounting KIT for 1000 test standard composition e Diamount mounting media xilolo free e coverglass 24x50mm or 24x60mm RAFFAELLO Maintenance KIT cod SDKRA1000 Maintenance KIT contains parts requiring replacement assorbent pad to put on the automatic 100 pcs activated charcoal filters 3 pcs running water supply piping washing water discharge piping washing water supply control electrovalve Smartcard with maintenaince st
6. n 1 Rack entering basin 7 8 Washing basins with running water 2 6 Stainer reagent basins 12 14 Stained slide deposit basins Stainer reagent basins PARK PARK PARK Hematoxylin Eosin Papanicolau 1 Ottix Plus 9 Ottix Shaper 1 Distilled water 9 EA50 2 Ottix Plus 10 Ottix Plus 2 Hematoxylin 10 Ottix Shaper 3 Ottix Shaper 11 Ottix Plus 3 Ottix Shaper 11 Ottix Shaper 4 Ottix Shaper 12 Ottix Plus 4 0OG6 12 Ottix Plus 5 Hematoxylin 13 Ottix Plus 5 Ottix Shaper 13 Ottix Plus 6 Eosin 14 Ottix Plus 6 Ottix Shaper 14 Ottix Plus 7 Water 7 Running water 8 Water 8 Running water Available accessories Code Description 53ESTXCA011 Water basin with valve for slides rack washing 53STX02 440 ml reagent basin in printed PET 53STX04 440 ml basin cover in printed PET with magnet SDSVI 1000 440 ml stainless steel reagent basin SDSVI1100 Set of 12 440 ml stainless steel reagent basins 53CV30 Plastic made rack for 1X3 slides 53STX01 20 Handle for 20 slide rack cod 53CV30 53STX01 30 Handle for 30 slide rack cod 53CV30 53STX10 Automatic arm absorbent pad packaging 100 pz SDSRA1001 Collecting shelf for reagent dropping BE049 CleanPath detergent for steel surfaces Diapath S p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000 www diapath com info diapath com 7 DIAPATH Technical features Instrument type Samples typology Slide productivity Storable protocol number Reagen
7. ngo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000 www diapath com info diapath com 5 data sheet Rev First emission 23 09 2010 COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 13485 2003 RAFFAELLO Stainer cod 53C0L02 and 53COL02 Temporary image of RAFFAELLO automatic stainer Control unity type PC with colour panel LCD touch screen Pentium processor Linux Embedded operative system Memory system extractable compact flash for software updatings Integrated LCD panel USB port for software upgrade and data saving as stainings protocols reagents index diagnostic log Agitation system available for every immersion rack Electromagnetic arm for covers if available Electromagnetic system for racks Reagent basins PE printed capacity 400 ml 1 rack of 30 slides carrier capacity Slide water washing basin 2 racks of 30 slides carrier capacity settable water flow through manual valve Activated charcoal filter batteries to vapour adsorption of not covered reagents O00000 Electric supply switch and automatic arm emergency stop botton Diapath S p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 986 411 Fax 39 0363 948 000 www diapath com info diapath com 6 data sheet Rev First emission 23 09 2010 COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 13485 2003 DIAPATH APPLICATIONS AND REAGENTS Basins illustratio
8. t basins number Washing basins number Charge position Deposit basin position Reagent vapours treatment Electric feeding Dimension and weight Dimension Bulk Dry weight Available models cod 53COL01 cod 53COL02 cata sneet COMPANY WATH QUALITY MAMACEM EST Rev First emission 23 09 2010 SYSTEM CERTIFIED BY GHY 50 13485 7003 Automatic stainer Histological tissues and cytological samples Using protocol Hematoxylin amp Eosin 100 slides hour Papanicolaou 100 slides hour Unlimited 9 basins with 1 rack of 30 slide carrier capacity 1 stainless steel basin with 2 racks of 30 slide carrier capacity 1 basin with 1 rack of 30 slide carrier capacity 3 basins with 1 rack of 30 slide carrier capacity Dedicated activated charcoal filter with forced ventilation 110 240 Vac 50 60Hz 160Watt 1150Lx500Px640H mm 1350Lx650Px700H mm 70 Kg RAFFAELLO BASIC automatic stainer RAFFAELLO ADVANCED automatic stainer with FMC Fast Maintenance Check including optimized protocols pre loaded in the software of control Through HELP DESK phone service skilled staff is at disposal for any suggestions and istructions concerning the use of the Staining KIT and of optimized protocols 8 Diapath p A Via Savoldini 71 24057 Martinengo BG Italy Tel 39 0363 966417 Faw 39 0363 948 000 Yvy diapath com infoeidiapath com
9. www diapath com info diapath com dl data sheet Rev First emission 23 09 2010 COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 13485 2003 Priority time staining 3 Advanced software functionf or the stainingt ime calculation Absolute respect warranty of rack immersion time in the used reagent and stainer thanks to the priority reagent basin option TIME OVER display and acoustic alarm when set staining time is different from those prefixed and parameterized Cover management 4 So east eer eran graye DI DIAPATH NUOVO REAGENTE 0 100 peel Exclusive staining managemet with reagent basins and dedicated covers Possibility to define in the Reagent Management System which reagents are equipped with cover This option decreases the evaporation of more volatile reagents reducing the dispersion of toxic harmful or irritating for the respiratory tracts vapours m ESL A Lad A E Sd Hao Alarm management 5 Aton io et 20 Mon el manutenriane Arets OF Alarm display through video icon and acoustic advise to draw operator s attention Date and hour saving of alarm advise The saved alarms concerns activated charcoal filters expiry date mechanical positioning alarm exhausted reagents and stainers staining door opening washing basin high level time over in the taining protocol ol Diapath S p A Via Savoldini 71 24057 Martine