Home
USER`S MANUAL - Simplified Safety
Contents
1. NOTES 1 THE ANCHOR AND PLYWOOD MUST BE INSTALLED TO A STRUCTURE CAPABLE OF RESISTING A 5 000 LB ULTIMATE LOAD 2 NECESSARY DECK REINFORCEMENT MAY INCLUDE BUT IS NOT LIMITED TO USING AN OVERLAY SHEET OF ADDITIONAL PLYWOOD LOCATING JOISTS UNDER ANCHOR PLATE EDGES AND APPLYING ADDITIONAL FASTENERS FOR THE PLYWOOD TO JOIST CONNECTION THE DECK USED FOR ANCHOR ATTACHMENT SHOULD BE INSPECTED FOR SIGNS OF ROT OR DECAY PRIOR TO INSTALLATION ANCHORS SHALL NOT BE INSTALLED ON ANY ROOF STRUCTURE WITH SIGNS OF DECAY THAT MAY COMPROMISE THE WITHDRAWAL CAPACITIES OF THE ROOF DECK SCREWS ANCHOR NOTES GUARDIAN FALL PROTECTION FALL PROTECTION ANCHORAGES ARE DESIGNED TO BE USED WITH ANSI Z359 1 APPROVED FALL PROTECTION EQUIPMENT FALL PROTECTION ANCHORAGES ARE DESIGNED FOR AN ULTIMATE LOAD OF 5 000 LBS WITHOUT FRACTURE OR DETACHMENT CONTACT A GUARDIAN FALL PROTECTION REPRESENTATIVE FOR CERTIFICATION TO USE AS A WINDOW WASHING TIE BACK ANCHOR GUARDIAN FALL PROTECTION DESIGNS THE ANCHOR TO STRUCTURE CONNECTION THE ABILITY OF THE STRUCTURE TO WITHSTAND THE DESIGN LOADS IS TO BE CHECKED BY OTHERS GUARDIAN FALL PROTECTION 26609 ave souTH INSTALLATION KENT WA 98032 800 466 6385 DETAILS WWW GUARDIANFALL COM Page 13 CB 12 INSTALLATION INSTRUCTIONS WELD ON ANCHOR DE
2. Age fitness and health conditions can seriously affect the worker should a fall occur Pregnant women and minors should not use this equipment ANSI 2359 0 2 27 defines a Competent Person as An individual designate d by the employer to be responsible for the immediate supervision implementation and monitoring of the employer s managed fall protection program who through training and knowledge is capable of identifying evaluating and addressingexisting and potential fall hazards and who has the employer s authority to take prompt corrective action with regard to such hazards Guardian Fall Protection 800 466 6385 www quardianfall com Page gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR TRAINING REQUIREM ENTS The employer must ensure that each employee who might be exposed to fall hazards has been trained by a Competent or Qualified Person The training program must include the following e The ability to recognize the hazards of falling e procedures to be followed in order to minimize these hazards All relevant Federal State and local regulatory requirements procedures and standards e Correct erecting maintaining disassembling and inspection of the fall protection systems being used e Useof personal fall arrest systems ANSI 2359 0 2 109 defines a Qualified Person as A person witha recognized degree or professional certificate and with extensive knowledge training and experience in
3. CB 12 ANCHOR TO THE GAGE OF METAL DECKING AS SHOWN OR THICKER IT IS RECOMMENDED THAT ALL OF THE PROVIDED HOLES IN THE ANCHOR BE USED TO SECURE THE ANCHOR TO THE METAL DECK BUT THE MINIMUM VALUES SHOWN MUST BE USED LONGER SCREWS MAY BE REQUIRED IN AREAS WHER A VOID EXISTS UNDER THE PLATE AND A 2 FASTENER CANNOT PENETRATE THE DECKING BY 1 4 OR MORE AFTER INSTALLATION FASTENERS MUST BE INSTALLED INTO A STRUCTURE THAT IS CAPABLE OF RESISTING A 5 000 LB ULT LOAD ANCHOR NOTES GUARDIAN FALL PROTECTION FALL PROTECTION ANCHORAGES ARE DESIGNED TO BE USED WITH ANSI Z359 1 APPROVED FALL PROTECTION EQUIPMENT FALL PROTECTION ANCHORAGES ARE DESIGNED FOR AN ULTIMATE LOAD OF 5 000 LBS WITHOUT FRACTURE OR DETACHMENT CONTACT A GUARDIAN FALL PROTECTION REPRESENTATIVE FOR CERTIFICATION TO USE AS A WINDOW WASHING TIE BACK ANCHOR GUARDIAN FALL PROTECTION DESIGNS THE ANCHOR TO STRUCTURE CONNECTION THE ABILITY OF THE STRUCTURE TO WITHSTAND THE DESIGN LOADS IS TO BE CHECKED BY OTHERS GUARDIAN FALL PROTECTION 26609 79h ave souTH INSTALLATION KENT WA 98032 800 466 6385 DETAILS WWW GUARDIANFALL COM Page 15 CB 12 INSTALLATION INSTRUCTIONS CONCRETE DECK ANCHOR DETAIL J EXISTING CONCRETE SLAB 1 2 HILTI HAS E ROD lt 2000 PSI MIN WITH SHOWN FOR REFERENCE REINFORCING BY OTHERS WITH 3 1 2 MINIMUM EMBEDMENT NOTES ANCHOR SHALL BE SECURED TO 2 000 PSI CONCRETE OR BETTER WITH 8 1 2 DIAMETER ANCHOR BOLTS HILTI 1 2 HAS E RODS
4. WITH HILTI HIT HY 150 HIT ICE IS SHOWN FOR REFERENCE ONLY USE AN EQUIVALENT OR SUPERIOR SYSTEM WHEN SUBSTITUTING FOLLOW ALL ANCHOR BOLT MANUFACTURER S INSTALLATION INSTRUCTIONS REGARDING MINIMUM CONCRETE THICKNESS TORQUE WEATHER TEMPERATURE AND INSTALLATION PROCEDURE ANCHOR NOTES 1 GUARDIAN FALL PROTECTION FALL PROTECTION ANCHORAGES ARE DESIGNED TO BE USED WITH ANSI 2359 1 APPROVED FALL PROTECTION EQUIPMENT 2 FALL PROTECTION ANCHORAGES ARE DESIGNED FOR AN ULTIMATE LOAD OF 5 000 LBS WITHOUT FRACTURE OR DETACHMENT CONTACT A GUARDIAN FALL PROTECTION REPRESENTATIVE FOR CERTIFICATION TO USE AS A WINDOW WASHING TIE BACK ANCHOR 3 GUARDIAN FALL PROTECTION DESIGNS THE ANCHOR TO STRUCTURE CONNECTION THE ABILITY OF THE STRUCTURE TO WITHSTAND THE DESIGN LOADS IS TO BE CHECKED BY OTHERS GUARDIAN FALL PROTECTION 26809 79in ave souTH INSTALLATION KENT WA 98032 800 466 6385 DETAILS WWW GUARDIANFALL COM For installations on other CB products please contact Guardian Fall Protection Page 16 CB 12 INSTALLATION INSTRUCTIONS WITH BACKER PLATE ANCHOR DETAIL GALVANIZED THREADED ROD ASSEMBLIES 4 PER ANCHOR TYP LOCATE RODS AT CORNER HOLES LI EXISTING CONCRETE SLAB AND DEFORM THREADS ON EACH MINIMUM DEPTH 2000 SIDE TO PREVENT TAMPERING TYP PSL MIN WITH REINFORCING BY OTHERS GALVANIZED BACKER PLATE PART 10681 16 16 3 8 STEEL PLATE 2 1 2 WASHERS amp 4 1 2 HEX NUTS 1 2 A307 THR
5. contact Guardian if you have a question regarding compatibility Making substitutions without approval from Guardian may lead to injuries and or death by compromising the safety and reliability of the complete system A Qualified Person can make a determination on compatibility of equipment from different manufacturers e COMPATIBILITY OF CONNECTORS Connectors D Rings hooks carabiners must be capable of supporting at least 5 000 lbs Non compatible connectors may unintentionally disengage Self locking and self closing snap hooks and carabiners are required by ANSI and OSHA Connectors must be compatible in size shape and strength e MAKING CONNECTIONS Only use sef closing double locking snaphooks and carabiners that are compliant to ANSI 2359 12 with any Guardian equipment Make only compatible connections If you have any questions on compatibility please call Guardian Guardian Fall Protection 800 466 6385 www quardianfall com Page 10 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR ANCHORAGE STRENGTH REQUIREM ENT The anchorage strength required is dependent on the application Ensure that any anchorage point used in the personal fall protection system meets the following requirements FALL ARREST The structure to which the anchorage connector is attached must sustain static loads applied in the directions permitted by the fall arrest system of at least 3 600 Ibs with the certification of a Qu
6. gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR GUARDIAN CB ANCHORS Model Numbers 00600 00601 00600 SS 00610 00645 00651 00652 00653 00656 00657 00680 00690 10681 10683 USER S MANUAL KEEP THIS FOR YOUR RECORDS AND TRAINING PURPOSES READ AND UNDERSTAND BEFORE USING EQUIPMENT GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR TABLE OF CONTENTS INTRODUCTION sette tenen Page 2 GENERAL SYSTEM SELECTION Page 3 TRAINING REQUIREMENTS ees Page 4 RESCUE P LAN sse trente tentent Page 4 MAINTENANCE CLEANING AND STORAGE Page 5 NS og To Page 5 APPLICABLE 5 Page 6 LIMITATIONS treten Page 6 SYSTEM REQUIREM ENTS ee Page 10 ANCHORAGE Page 11 PRIOR TO EACH USE ene Page 12 PLAN YOUR FALL PROTECTION SYSTEM coe Page 12 INSTALLATION GUIDELINES cccccccecessesesecseseseeeseeeceee Page 13 USER INFORMATION er nentes Page 18 INSPECTION LOG eet en Page 18 INTRODUCTION Thank you for purchasing this Guardian Fall Protection equipment This manual should be read and understood inits entirety and used as part of a training program as required by OSHA ANSI CSA or any applicable state regulatory agency This and any other included instructions must be made available
7. EADED ROD CUT TO LENGTH IN FIELD THREADED ROD ASSEMBLY CB 12 BACKER PLATE PART 10681 ANCHOR NOTES 1 GUARDIAN FALL PROTECTION FALL PROTECTION ANCHORAGES ARE DESIGNED TO BE USED WITH ANSI Z359 1 APPROVED FALL PROTECTION EQUIPMENT 2 FALL PROTECTION ANCHORAGES ARE DESIGNED FOR AN ULTIMATE LOAD OF 5 000 LBS WITHOUT FRACTURE OR DETACHMENT CONTACT A GUARDIAN FALL PROTECTION REPRESENTATIVE FOR CERTIFICATION TO USE AS A WINDOW WASHING TIE BACK ANCHOR GUARDIAN FALL PROTECTION DESIGNS THE ANCHOR TO STRUCTURE CONNECTION THE ABILITY OF THE STRUCTURE TO WITHSTAND THE DESIGN LOADS IS TO BE CHECKED BY OTHERS GUARDIAN FALL PROTECTION 26609 ave SOUTH INSTALLATION 800 466 6385 DETAILS WWW GUARDIANFALL COM 3 Page 17 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR USER INFORM ATION Date of First Use Serial Trainer Please fill out this out and keep for your records INSPECTION LOG INSPECT EQUIPMENT BEFORE EACH USE COMPETENT PERSON MUST INSPECT amp INITIAL EVERY SIX MONTHS Date Name Guardian Fall Protection 800 466 6385 www quardianfall com Page 18 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR NOTES Guardian Fall Protection 800 466 6385 www quardianfall com Page 19 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR SKETCH PROTECTION PLAN SKETCH AREA Guardian Fall Protection 800 466 6385 www quardianfall com Page 20 gt GUARDIAN FALL P
8. REE FALL FINAL HEIGHT OF D RING ABOVE WORKER S TOES SAFETY FACTOR Guardian Fall Protection 800 466 6385 www quardianfall com Page 7 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR LIMITATIONS continued e SWING FALLS Swing falls occur when the anchorage point is not directly above the point where fall occurs The force of striking an object in swing fall may cause serious injury or death Do NOT permit swing falls as injuries could occur Swing falls will significantly increase the clearance required when self retracting lifeline or other variable length connecting system is used The free fall from swing fall must not be more than four feet per ANSI Z359 6 2009 5 3 Swing Falls e POTENTIAL ENVIRONMENTAL HAZARDS Use of fall protection equipment in areas with environmental hazards may require additional precautions to prevent injury to the user or damage to the equipment Hazards may include but are not limited to chemicals corrosive environments high voltage power lines gases moving machinery and sharp edges SNAPHOOKS AND CARABINERS MUST BE SELF CLOSING AND SELF LOCKING THEY MUST WITHSTAND A 5 000 LBS LOAD THE GATE OF THE SNAPHOOK OR CARABINER MUST WITHSTAND A 3 600 LBS SIDE LOAD FOR MORE INFORMATION SEE ANSI 359 12 2009 3 1 1 3 Guardian Fall Protection 800 466 6385 www quardianfall com Page 8 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR LIMITATIONS continued
9. ROTECTION PERFORMANGE SAFETY GEAR WE PUT OUR NAME ON THE PRODUCT BECAUSE YOU PUT YOUR LIFE ON THE LINE Guardian Fall Protection Inc 800 4666385 26609 79 Ave S Kent WA 98032 www quardianfall com SE Guardian Fall Protection 800 466 6385 www quardianfall com Page 21
10. TAIL GUARDIAN CB 12 WELD ON POST NOTES WELD CB 12 TO A STRUCTURAL MEMBER CAPABLE OF RESISTING A 5 000 LB LOAD USING A 5 16 FILLET WELD ALL WELDING SHALL BE PERFORMED BY AN AWS D1 1 CERTIFIED WELDER USING E 70XX ROD OR WIRE FEED PREP GALVANIZED AREAS PER AWS D19 0 PRIOR TO WELDING TOUCH UP GALVANIZED AREA AFTER WELDING PER ASTM A780 ANCHOR NOTES GUARDIAN FALL PROTECTION FALL PROTECTION ANCHORAGES ARE DESIGNED TO BE USED WITH ANSI Z359 1 APPROVED FALL PROTECTION EQUIPMENT FALL PROTECTION ANCHORAGES ARE DESIGNED FOR AN ULTIMATE LOAD OF 5 000 LBS WITHOUT FRACTURE OR DETACHMENT CONTACT A GUARDIAN FALL PROTECTION REPRESENTATIVE FOR CERTIFICATION TO USE AS A WINDOW WASHING TIE BACK ANCHOR GUARDIAN FALL PROTECTION DESIGNS THE ANCHOR TO STRUCTURE CONNECTION THE ABILITY OF THE STRUCTURE TO WITHSTAND THE DESIGN LOADS IS TO BE CHECKED BY OTHERS GUARDIAN FALL PROTECTION 26609 Tem ave SOUTH INSTALLATION KENT WA 98032 800 466 6385 DETAILS WWW GUARDIANFALL COM Page 14 CB 12 INSTALLATION INSTRUCTIONS METAL DECK ANCHOR DETAIL NEW e xe 20 GAUGE MIND STEEL PLATE FASTENED METAL DECK WITH 1 4 14 SCREWS OR EQUAL ARDUND ENTIRE PERIMETER AT 3 OC 36 14 10 2 SCREWS FOR METAL DECK 40 14 10 2 SCREWS FOR METAL DECK NENNEN D00000O00C0000000000000Q0CQCG 6262 OOO OOOO OOO Oe RI 5505 GALVANIZED 24 GALVANIZED METAL DECK OR BETTER METAL DECK OR BETTER SECURE THE
11. alified Person or 5 000 Ibs without certification Refer to OSHA and ANSI for specific definition This anchor is to be used by one worker only unless otherwise determined by a Qualified Person or manufacturer If an HLL system is being used follow manufacturer s instructions and specifications Anchorages used for attachment of a personal fall arrest system shall be independent of any anchorage being used to support or suspend platforms Maximum permissible free fall is six feet RESTRAINT The structure to which the anchor point is attached must sustain static loads applied in the directions permitted by the restraint system or at least 3 000 Ibs Free fall must be restricted to two feet or less WORK POSITIONING The structure to which the anchor point is attached must sustain static loads applied in the directions permitted by the work positioning system of at least 3 000 Ibs or twice the potential impact load whichever is greater Free fall must be restricted to two feet or less RESCUE The structure to which the anchor point is attached must sustain static loads of at least 3 000 Ibs or twice the potential impact load whichever is greater NO VERTICAL FREE FALLIS PERMITTED Guardian Fall Protection 800 466 6385 www quardianfall com Page 11 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR PRIOR TO EACH USE In accordance with ANSI standards the requirements below must be followed e Fall protection equi
12. ase contact Guardian for alternatives FREE FALL Personal Fall Arrest Systems PFAS used with this equipment must be rigged to limit the freefall to six 6 feet as called out in ANSI 2359 1 Free fall can be further with a connected subsystem designed for extended free fall Only Qualified Persons and personnel trained on the proper use of fall protection such as this anchor are allowed to use this product Guardian Fall Protection 800 466 6385 www quardianfall com Page 6 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR LIMITATIONS continued FALL CLEARANCE There must be sufficient clearance below the user to arrest a fall before the user strikes the ground or any other obstruction A hazard assessment by a trained and Competent Person is recommended before any work is started that would include the use of fall protection e FALL ARREST DISTANCE Consult the image below to help deter mine your total fall arrest distance OVERHEAD ANCHORAGE LENGTH OF LANYARD THE LENGTH OF LANYARD USED IN THIS EXAMPLE IS A SIX FOOT LANYARD THAT COMPLIES WITH ANSI 2359 1 07 o DECELERATION DISTANCE DISTANCE WILL DEPEND ON TYPE OF SHOCK PACK USED AND DISPLACEMENT OF ANCHORAGE SYSTEM 20 WARNING THE DISTANCES SHOWN ARE ESTIMATES FOR ILLUSTRATION PURPOSES ONLY ADDITIONAL HEIGHT MUST BE ANALYZED FOR ANCHORAGE POINTS 7 6 BELOW THE DORSAL D RING SWING FALL POTENTIAL AND SYSTEMS THAT PERMIT EXTENDED F
13. e CORRECT ANCHORAGE POSITIONING Consult the chart and diagram below to determine the safe angles from which you can work when tied off to single anchor point Key X Working Distance Along Roof Edge Y Distance from Leading Edge O Total Working Angle SINGLE ANCHOR POINTS Note This chart details allowable working zones for swing fall based on ANSI 2359 6 2009 5 3 Swing Falls In fall arrest systems anchorages shall be located directly above the worker s to eliminate swing falls wherever it is reasonably practical to do so Where it is not reasonably practical to prevent swing falls the swing drop distance shall not exceed 4 0 ft 1 22m Distance from Working Distance Leading Edge Along Roof Edge Y Either Direction X 60 8 53Degees 10 9 9 45Degrees 38Degrees 18 30 33Degrees 25 148 30Degrees Working Angle From Perpindicular 8 30 _ 16 28Degres 172 26Degres 40 18 3 24Degrees 458 of 19 4 23Degrees 50 19 10 21Degrees 5 21 4 21Degrees 60 223 Degrees Guardian Fall Protection 800 466 6385 www quardianfall com Page 9 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR SYSTEM REQUIREMENTS e COMPATIBILITY OF COMPONENTS Guardian Fall Protection equipment is designed to be used with Guardian approved components Please
14. ll fall protection equipment A formal inspection must be made by a Competent or Qualified Person other than the user at least every six months Record the results of these inspections in the Inspectio n Log in the back of this manual Visually inspect all components of the equipment looking for signs of corrosion cracks deformation and other damage IF GUARDIAN EQUIPM ENT DOES NOT PASS INSPECTION REMOVE FROM SERVICE IMMEDIATELY Guardian Fall Protection 800 466 6385 www quardianfall com Page 5 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR DO NOT HANG EQUIPM ENT RIGGING OR STAGING FROM FALL PROTECTION ANCHOR POINTS APPLICABLE STANDARDS This productis designed to comply with OSHA ANSI and CSA standards when used properly in accordance with manufacturer s instructions Standards might include OSHA regulations depending on the type of work being done and also might include state regulations if applicable Consult regulatory agencies for more information on personal fall arrestsystems and associated components LIMITATIONS Consider the following application limitations before using this equipment e CAPACITY Guardian equipment is designed for use by persons with a combined weight clothing tools etc of no more than 310 Ibs using an approved connecting system No more than one personal protective system may be connected at one time If you require a combined weight of 310 Ibs 400 Ibs ple
15. pment shall be inspected by the user for defects damage and deterioration e Any suspected defective equipment shall be removed from service e If the manufacturer s label is not legible or is missing the equipment shall be removed from service e If it is necessary to remove Guardian equipment during a portion of a particular job make sure to re secure the equipment before resuming work PLAN YOUR FALL PROTECTION SYSTEM Before installation plan your system Consider all factors that will affect your safety during use of this equipment The following list gives important points to consider e ANCHORAGE Select a rigid anchorage capable of supporting loads of no less tha n 5 000 Ibs without certification and 3 600 Ibs with certification from a Qualified Person e SHARP EDGES Avoid working where system components may be in contact with or abrade against unprotected sharp edges e AFTER A FALL Components which have been subjected to the forces of arresting fall MUST be removed from service e RESCUE OSHA requires that the employer have a site specific rescue plan when using this equipment The employer must have the ability to perform rescue quickly and safely Guardian Fall Protection 800 466 6385 www quardianfall com Page 12 INSTALLATION GUIDELINES CB 12 INSTALLATION INSTRUCTIONS WOOD DECK ANCHOR DETAIL 0 0 00 40 gt 14 10 2 SCREWS FOR WOOD DECK 9 8 CDX PLYWOOD
16. the fall protection and rescue field who is capable of designing analyzing evaluating and specifying fall protection and rescue systems to the extent required by this standard RESCUE PLAN OSHA 1926 502 d 20 states The employer shall provide for prompt rescue of employees in the event of a fall or shall assure that employees are able to rescue themselves The rescue plan shall be project specific Employees shall be trainedin self rescue or alternate means shall be provided for prompt rescue in the event of a fall EQUIPMENT SUBJECTED TO THE FORCES OF A FALL MUST BE REMOVED FROM SERVICE IMMEDIATELY Guardian Fall Protection 800 466 6385 www quardianfall com Page 4 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR MAINTENANCE CLEANING AND STORAGE Repairs to Guardian Equipment can be made only by a Guardian representative or entity authorized by Guardian Contact Guardian for maintenance and repair Cleaning after use is important for maintaining the safety and life of the equipment Cleanse the equipment of all dirt corrosives and contaminants If equipment cannot simply be wiped clean use mild soap and water rinse wipe to dry OSHA ANSI and CSA require that equipment is stored in manner as to preclude damage from environmental factors such as heat light excessive moisture oil chemicals and their vapors or other degrading elements INSPECTION Before each use the worker must inspect a
17. to the users of the equipment The user must understand proper equipment use and limitations This manual covers the maintenance and use of equipment made and sold by Guardian Fall Protection See supplemental material for specific installation instructions Guardian Fall Protection 800 466 6385 www quardianfall com 2 gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR DO NOT alter the equipment DO NOT misuse the equipment DO NOT use combinations of components or subsystems that may affect or interfere with the safe compatible function of each other DO NOT expose the equipment to chemicals that may produce harmful effect or degra de the equipment Consult manufacturer in cases where doubt exists DO NOT use the equipment around moving machinery or electrical hazards unless specifically designed for such use DO NOT use the equipment around sharp edges or abrasive surfaces unless intended for such use GENERAL SYSTEM SELECTION CRITERIA Selection of fall protection shall be made by a Competent Person All fall protection equipment shall be purchased new and unused The equipment is designed for use as a part of a personal fall protection system Components shall not be used for any other operation other than that which it has been designed and approved for Consult a doctor if there is any reason to doubt a user s ability to withstand and safely absorb fall arrest forces or perform setup of equipment
Download Pdf Manuals
Related Search
Related Contents
MODE D EMPLOI LIBRARY B FUNCTION BLOCKS INSTRUCTION MANUAL Polar CS600X User's Manual OKI V19B-PHDUV Manual - Recambios, accesorios y repuestos Samsung Лазерний принтер ML-2955ND Керівництво користувача to the SimpleSEO Rank Checker User Manual User Manual Envío de imágenes a un smartphone/tableta (Comparte con Samsung LW20M21CP Uživatelská přiručka Copyright © All rights reserved.