Home

Industrial Unmanaged Ethernet Switches and Media Converter

image

Contents

1. ON Solid not flashing Indicates that there is a proper Ethernet connection Link between the port and another Ethernet device but no communications activity is detected Flashing Indicates that there is a proper Ethernet connection Link between the port and another Ethernet device and that there is communications activity Green A 100 Mbps 100BaseT connection is detected Yellow A 10 Mbps 10BaseT connection is detected OFF Fiber LED Indicates that there is not a proper Ethernet connection Link between the port and Au eae device Make sure the cable has been plugged securely into the ports at both ends This is the Green LED on Models SE SW5U and SE MC2U with yellow and a green LED per RJ45 port ON green not flashing Indicates that there is a proper fiber connection Link between the port and another fiber device but no communications activity is detected ON green flashing Indicates that there is a proper fiber connection Link between the port and another fiber device and that there is communications activity OFF amp I Ist Ed Rev C 07 11 Indicates that there is not a proper fiber connection Link between the port and another Lee O Make sure the fiber optic cable has been plugged securely into the ports at oth ends Industrial Unmanaged Ethernet Switches amp Media Converters Installation Plastic Case Switches Overview T
2. RJ45 copper Ethernet ports and one fiber optic Ethernet port on some models RJ45 Ethernet Wiring Use data quality not voice quality twisted pair cable rated category 5 or better with standard RJ45 connectors Straight through or crossover Ethernet cable can be used for all devices the switch is connected to as all the ports are capable of auto mdi mdix crossover detection The RJ45 Ethernet port connector bodies on these products are metallic and connected to the Chassis GND terminal Therefore shielded cables may be used to provide further protection To prevent ground loops the cable shield should be tied to the metal connector body at one end of the cable only Electrical isolation is also provided on the Ethernet ports for increased reliability Straight thru Cable Wiring Cross over Cable Wiring al Note For reference only Either cable wiring will work Ethernet Plug amp Connector Pin Positions 16 Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters RJ45 Cable Distance The maximum cable length for 10 100BaseT is 100 meters 328 ft Ethernet Fiber Wiring Guidelines The industrial Ethernet switches and media converters optionally have one pair of 100 Mbps 100BaseFX multimode fiber ports The maximum segment length is 4 km Each fiber optic port on the switch comprises a pair of ST or SC style connectors depending on the model For each fiber por
3. necesita informaci n adicional por favor ll menos al n mero 770 844 4200 en Estados Unidos Esta publicaci n est basada en la informaci n disponible al momento de impresi n En AutomationDirect com nos esforzamos constantemente para mejorar nuestros productos y servicios as que nos reservamos el derecho de hacer cambios al producto y o a las publicaciones en cualquier momento sin notificaci n y sin ninguna obligaci n Esta publicaci n tambi n puede discutir caracter sticas que no est n disponibles en ciertas revisiones del producto Marcas Registradas Esta publicaci n puede contener referencias a productos producidos y u ofrecidos por otras compa as Los nombres de las compa as y productos pueden tener marcas registradas y son propiedad nica de sus respectivos due os Automationdirect com renuncia cualquier inter s propietario en las marcas y nombres de otros PROPIEDAD LITERARIA 2007 2011 AUTOMATIONDIRECT COM INCORPORATED Todos los derechos reservados No se permite copiar reproducir o transmitir de ninguna forma ninguna parte de este manual sin previo consentimiento por escrito de AutomationDirect com Incorprated AutomationDirect com retiene los derechos exclusivos a toda la informaci n incluida en este documento Los usuarios de este equipo pueden copiar este documento solamente para instalar configurar y mantener el equipo correspondiente Tambi n las instituciones de ense anza pueden usar este manual par
4. maintain the UL 508 listing this must be a Class 2 power supply DC voltage in the range of 10 to 30 VDC needs to be applied between the P1 plus terminal and the Minus terminal as shown below The chassis screw terminal should be tied to panel or chassis ground To reduce down time resulting from power loss these industrial Ethernet switches can be powered redundantly with a second power supply as shown below Single DC Power Redundant DC Power Chassis Chassis GND GND panel panel One DC Supply Dual DC Supplies Screw Torque When tightening the screws be careful to tighten to a max torque of 5 lb in 0 57 Nm Wire size should be between 24 AWG and 12 AWG e The area is currently nonhazardous especially when working in Class 1 Div 2 or Zone 2 hazardous locations e Power is off to the switch e The screw terminal block is unplugged This is especially important on the aluminum housed units as shown below Connecting or disconnecting wires to the screw block when its in place and power is turned on can allow the screwdriver to short the power to the case Before performing any wiring to these switches make sure Ist Ed Rev C 07 11 15 St rid User Manual Communication Ports Wiring Overview The industrial Ethernet switches and media converters provide connections to standard Ethernet devices such as PLCs Ethernet I O industrial computers and much more Two types of communication ports are available
5. normes applicables peut entra ner des dommages l quipement ou causer de graves blessures au personnel Nous ne garantissons pas que les produits d crits dans cette publication conviennent votre application particuli re et nous n assumons aucune responsabilit l gard de la conception de l installation ou du fonctionnement de votre produit Nos produits ne sont pas insensibles aux d faillances et ne sont ni con us ni fabriqu s pour l utilisation ou la revente en tant qu quipement de commande en ligne dans des environnements dangereux n cessitant une s curit absolue par exemple l exploitation d installations nucl aires les syst mes de navigation a rienne ou de communication le contr le de la circulation a rienne les quipements de survie ou les syst mes d armes pour lesquels la d faillance du produit peut provoquer la mort des blessures corporelles ou de graves dommages mat riels ou environnementaux activit s risque lev La soci t AutomationDirect nie toute garantie expresse ou implicite d aptitude l emploi en ce qui a trait aux activit s risque lev Pour des renseignements additionnels touchant la garantie et la s curit veuillez consulter la section Modalit s et conditions de notre documentation Si vous avez des questions au sujet de l installation ou du fonctionnement de cet quipement ou encore si vous avez besoin de renseignements suppl mentaires n h sitez pas nous t l p
6. EMA la Asociaci n Nacional de Fabricantes El ctricos de USA Puede haber oficinas de normas locales o del gobierno que pueden ayudar a determinar cuales c digos y normas son necesarios para una instalaci n y operaci n segura Si no se siguen todos los c digos y normas aplicables puede resultar en da os al equipo o lesiones serias a personas No garantizamos los productos descritos en esta publicaci n para ser adecuados para su aplicaci n en particular ni asumimos ninguna responsabilidad por el dise o de su producto la instalaci n u operaci n Nuestros productos no son tolerantes a fallas y no han sido dise ados fabricados o intencionados para uso o reventa como equipo de control en l nea en ambientes peligrosos que requieren una ejecuci n sin fallas tales como operaci n en instalaciones nucleares sistemas de navegaci n a rea o de comunicaci n control de tr fico a reo m quinas de soporte de vida o sistemas de armamentos en las cuales la falla del producto puede resultar directamente en muerte heridas personales o da os f sicos o ambientales severos Actividades de Alto Riesgo AutomationDirect com espec ficamente rechaza cualquier garant a ya sea expresada o implicada para actividades de alto riesgo Para informaci n adicional acerca de garant a e informaci n de seguridad vea la secci n de T rminos y Condiciones de nuestro cat logo Si tiene alguna pregunta sobre instalaci n u operaci n de este equipo o si
7. Issue both shown below when communicating with Technical Support regarding this publication Manual Number SE USER M Issue Ist Edition Rev C Issue Date 07 11 Publication History Issue Description of Changes 1st Edition Original issue Rev A Corrected table on page 4 Rev B Added high temp WT models Rev C Added SC fiber port models INDUSTRIAL UNMANAGED ETHERNET SWITCHES amp MEDIA CONVERTERS In This User Manual INTEOQUETION aserrada ve Hae eee S 2 Conventions USE ioe pe hae wees Coe EEE SSE OE ae a a oe oe eS 2 Product OVGIVIEW cenas rar Qw Seleme eee cee weenie de aoe wees 3 General NIORMNGUON ss 542544044 res ie eee oo aies LED Ip AO Le ee susu cu 7 Installation Plastic Case Switches 9 Installation Metal Case Switches 10 Communication Ports Wiring 16 Technical Specifications 0 sense See BES ODT ee 19 RoHS c UL us FC pi Electrical Safety European Directives US Emissions WEEE Compliant RoHS Compliant St rid User Manual Introduction The Purpose of this User s Manual Thank you for purchasing our Stride Industrial Ethernet Switches and Media Converters This manual describes AutomationDirect coms Stride industrial Ethernet switches and media converters their specifications included components and p
8. Master Module p n H2 ERM F amp H4 ERM F Verifying Connectivity After all Ethernet and or fiber connections are made check the LEDs corresponding to the ports that each of the devices are connected to Ensure that for each port that is in use the LED is on or blinking If a port LED is off go back and check for connectivity problems between that port and the network device connected to that port In addition the color of the LED should indicate the speed at which your device is connected see prior section on LEDs 18 Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters JU U UJ Technical Specifications Technical Specs Here are the hardware technical specifications for the industrial Ethernet switches and media converters covered by this manual Copper RJ45 Ports 10 100BaseT ports Copper RJ45 Ports 10 100BaseT Shielded RJ45 Protocols supported All standard IEEE 802 3 Ethernet compliancy IEEE 802 3 802 3u 802 3x Auto crossover Yes allows you to use straight through or crossover wired cables Auto sensing operation Yes Full and half duplex Auto negotiating Yes 10BaseT and 100BaseT Auto polarity Yes on the TD and RD pair Flow control Automatic Ethernet isolation 1500 VRMS 1 minute Plug and play Yes Cable requirements Twisted pair Cat 5 or better shielded recommended Max cable di
9. N50021 EN60079 15 Zone2 RoHS and WEEE RoHS Pb free and WEEE compliant SE MC2U ST SE MC2U SC SE SW5U ST UL94V0 Lexan IP30 SE SWSU SC Packaging and protection eae SE SW5U WT SESWSU STWT SE SW9U ST WT Aluminum IP30 SE SW5U SC WT SE SW9U SC WT Dimensions L x W x H See mechanical diagrams for details SE SW5U SE SW5U ST SE SW5U SC 4 oz 0 11 kg SE MC2U ST SE MC2U SC SE SWSU SI Weights typical I SE SW9U SC SE SW5U WT 6 oz 0 17 kg SE SW5U ST WT SE SW5U SC WT SE SW8U WT SE SW9U ST WT 8 oz 0 23 kg SE SW9U SC WT Ist Ed Rev C 07 11 21 Automation
10. Stride USER MANUAL y 5 gt w E LU s oH amp c Y S gt Es ce gt Co Y HU 5 ES M USER Manual Number SE M WARNING y Thank you for purchasing automation equipment from AutomationDirect com doing business as AutomationDirect We want your new automation equipment to operate safely Anyone who installs or uses this equipment should read this publication and any other relevant publications before installing or operating the equipment To minimize the risk of potential safety problems you should follow all applicable local and national codes that regulate the installation and operation of your equipment These codes vary from area to area and usually change with time It is your responsibility to determine which codes should be followed and to verify that the equipment installation and operation is in compliance with the latest revision of these codes At a minimum you should follow all applicable sections of the National Fire Code National Electrical Code and the codes of the National Electrical Manufacturer s Association NEMA There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards We do not guarantee the products described in this publication are sui
11. WT models have a metal case and are rated for a wider temperature range from 40 to 85 C STRIDE SlimLine Industrial Unmanaged Ethernet Switch a E aa with eight 10 100BaseT RJ45 Ethernet Ports and one SE SW9U ST ie a 100BaseFX Fiber Optic Port ST or SC type multimode fiber SE SW9U SC H _ connector for links up to 4km Redundant power inputs F an TTY with surge and spike protection Auto crossover DIN rail SE SW9U ST WT an ah ah mounting Supports store amp forward wire speed switching SE SW9U SC WT am al as ai QE J and full duplex with flow control UL CSA CUL amp CE Note WT models have a metal case and are rated for a wider temperature range from 40 to 85 C STRIDE SlimLine Industrial Unmanaged Ethernet to Fiber Converter with one 10 100BaseT auto detecting f auto crossover and auto polarity RJ45 Ethernet Port and SE MC2U ST x I one 100BaseFX Fiber Optic Port ST or SC type multimode SE MC2U SC fiber connector for links up to 4km Redundant power Ji inputs with surge and spike protection DIN rail mounting Supports store amp forward wire speed switching and full duplex with flow control UL CSA CUL amp CE Ist Ed Rev C 07 11 I 3 St rid User Manual General Information Overview This user s manual will help you install and maintain the STRIDE Industrial Ethernet Switches and Media Converters Installation of t
12. a prop sitos educativos M AVERTISSEMENT y Nous vous remercions d avoir achet l quipement d automatisation de AutomationDirect com en faisant des affaires comme AutomationDirect Nous tenons ce que votre nouvel quipement d automatisation fonctionne en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publication et toutes les autres publications pertinentes avant de l installer ou de l utiliser Afin de r duire au minimum le risque d ventuels probl mes de s curit vous devez respecter tous les codes locaux et nationaux applicables r gissant l installation et le fonctionnement de votre quipement Ces codes diff rent d une r gion l autre et habituellement voluent au fil du temps Il vous incombe de d terminer les codes respecter et de vous assurer que l quipement l installation et le fonctionnement sont conformes aux exigences de la version la plus r cente de ces codes Vous devez tout le moins respecter toutes les sections applicables du Code national de pr vention des incendies du Code national de l lectricit et des codes de la National Electrical Manufacturer s Association NEMA Des organismes de r glementation ou des services gouvernementaux locaux peuvent galement vous aider d terminer les codes ainsi que les normes respecter pour assurer une installation et un fonctionnement s rs L omission de respecter la totalit des codes et des
13. and or offered by other companies The product and company names may be trademarked and are the sole property of their respective owners AutomationDirect disclaims any proprietary interest in the marks and names of others Copyright 2007 2011 AutomationDirect com Incorporated All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without the prior written consent of AutomationDirect com Incorporated AutomationDirect retains the exclusive rights to all information included in this document M ADVERTENCIA y Gracias por comprar equipo de automatizaci n de AutomationDirect com Deseamos que su nuevo equipo de automatizaci n opere de manera segura Cualquier persona que instale o use este equipo debe leer esta publicaci n y cualquier otra publicaci n pertinente antes de instalar u operar el equipo Para reducir al m nimo el riesgo debido a problemas de seguridad debe seguir todos los c digos de seguridad locales o nacionales aplicables que regulan la instalaci n y operaci n de su equipo Estos c digos varian de rea en rea y usualmente cambian con el tiempo Es su responsabilidad determinar cuales c digos deben ser seguidos y verificar que el equipo instalaci n y operaci n est n en cumplimiento con la revisi n mas reciente de estos c digos Como m nimo debe seguir las secciones aplicables del C digo Nacional de Incendio C digo Nacional El ctrico y los c digos de N
14. ation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note All information in this document is subject to change without notice I Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters LED Indicators Overview All of the Stride Industrial Ethernet Switches and Media Converters have 1 or 2 communication LEDs for each port and a power LED The fiber models also have one Fiber LED located next to the Power LED The Fiber LED will be ON solid when you have made a proper connection Refer to the sample pictures below for the location of these LEDs The activity link and speed LEDs are Potten net S nthe The activity ds tria
15. er typical with all port w o fiber 5 port w 1 fiber SE SW5U ST SE SW5U SC SE SW5U ST WT and SE SW5U SC WT ports active at 100 Mbps B port w o fiber SE SW8U SE SW8U WT 9 port w 1 fiber SE SW9U ST SE SW9U SC SE SW9U ST WT and SE SW9U SC WT Input voltage all models 10 30 VDC continuous Class 2 Power Supply Reverse power protection Yes Transient protection 15 000 watts peak Spike protection 5 000 watts 10x for 10 uS Ethernet isolation 1500 VRMS 1 minute General specifications continued on the next page 20 i Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters Technical Specifications cont d General Specifications contd General Specifications cont d SE MC2U ST SE MC2U SC SE SW5U SE SW8U 10 to 60 C 14 to 140 F SE SW5U ST cold startup at 10 C 414 F SE SW5U SC Operating temperature range u SE SW5U WT SE SW8U WT SE SW5U ST WT 40 to 85 C 40 to 185 F SE SW9U ST WT cold startup at 40 C 40 F SE SW5U SC WT SE SW9U SC WT Storage temperature range 40 to 85 C 40 to 185 F Humidity non condensing 5 to 95 RH Environmental Air No corrosive gasses permitted Vibration shock amp freefall IEC68 2 6 27 32 Electrical safety UL508 CSA C22 EN61010 1 EMI emissions FCC part 15 ICES 003 EN55022 EMC immunity IEC61326 1 UL1604 CSA C22 2 213 Class I Div 2 file E200031 Hazardous locations E
16. ers Product Overview Industrial Unmanaged Ethernet Switches and Media Converters Part Number Description STRIDE SlimLine Industrial Unmanaged Ethernet Switch with five 10 100BaseT RJ45 Ethernet ports Redundant J power inputs with surge and spike protection Auto SE SW5U in a DIN E e ou amp Pei E wire speed switching and full duplex with flow control UL AL CSA CUL amp CE Note WT models have a metal case and are rated for a wider temperature range from 40 to 85 C STRIDE SlimLine Industrial Unmanaged Ethernet Switch with eight 10 100BaseT RJ45 Ethernet ports Redundant power inputs with surge and spike protection Auto SE SW8U pu oo DIN i e porr h amp ae r p wire speed switching and full duplex with flow control UL SE SW8U WT CSA CUL amp CE Note WT models have a metal case and are rated for a wider temperature range from 40 to 85 C z STRIDE SlimLine Industrial Unmanaged Ethernet Switch kms cS ss with four 10 100BaseT RJ45 Ethernet Ports and one SE SW5U ST en 100BaseFX Fiber Optic Port ST or SC type multimode fiber SE SW5U SC e 11 connector for links up to 4km Redundant power inputs gt H 14 i with surge and spike protection Auto crossover DIN rail SE SWSU ST WT a mounting Supports store amp forward wire speed switching SE SWSU SC WT ali a and full duplex with flow control UL CSA CUL amp CE Note
17. et the following standards plus others Electrical Safety CE per Low Voltage Directive and EN61010 1 IEC 1010 UL recognition per UL508 UL File E200031 CSA per C22 2 14 CUL File E200031 See Warnings on following page Install the Switches in accordance with local and national electrical codes Lightning Danger Do not work on equipment during periods of lightning activity Do not connect a telephone line into one of the Ethernet RJ45 connectors EMC emmissions and immunity e CE per the EMC directive EN 55022 or IEC 61326 1 or EN 61000 6 2 4 e FCC part 15 and ICES 003 Class B See FCC statement on following page Marine maritime and offshore These devices when installed in an appropriately IP rated enclosure Comply with DNV No 2 4 and equivalent Lloyds and ABS standards For marine and maritime compliance do not install this product within 5 meters of a standard or a steering magnetic compass WEEE compliance These devices comply with the WEEE directive Dispose of properly RoHS compliance These devices comply with the RoHS directive and are considered lead and other hazardous substance free Hazardous Locations e CE per ATEX directive and EN50021 EN60079 15 Zone 2 EEx nA II T4 X 40 C lt T 85 C e UL per UL1604 Class 1 Div 2 Groups A B C D UL File E200031 e CSA per C22 2 213 Class 1 Div 2 Groups A B C D cUL File E200031 See Warnings on followin
18. g page Ist Ed Rev C 07 11 5 St rid User Manual A 6 Installation and Hazardous Area Warnings WARNING These products should not be used to replace proper safety interlocking No software based device or any other solid state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular AutomationDirect com disclaims any responsibility for damages either direct or consequential that result from the use of this equipment in any application All power input and output 1 0 wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR EXPLOSION HAZARD CLASS 1 DIVISION 2 ZONE 2 WARNING WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE EXPLOSION HAZARD REPLACING OR WIRING UNITS DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN WARNING EXPLOSION HAZARD SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS WARNING NOT SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED USE THE EXPLOSION HAZARD UNIT FOR INTERNAL CONNECTIONS ONLY ECC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential install
19. hese devices is very easy and they will begin to operate as soon as they are powered up Operation Unlike an Ethernet hub that broadcasts all messages out all ports these industrial Ethernet switches will intelligently route Ethernet messages only out the appropriate port The major benefits of this are increased bandwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems These industrial Ethernet switches can support 10BaseT 10 Mbps and 100BaseT 100 Mbps on their RJ45 ports Each of these ports will independently auto sense the speed and duplex mdi mdix crossover and polarity allowing you to use straight crossed or even mis wired cables Some models also have one 100BaseFX 100 Mbps fiber optic port for making noise immune connections up to 4 km Performance Specifications These general specifications apply to these industrial Ethernet switches Refer to the Technical Specifications topic for complete details Number of ports 2 5 8 or 9 Ethernet ports Ethernet Switch Type Unmanaged Ethernet Protocols All standard IEEE 802 3 RJ45 Ports shielded 10 100BaseT with auto negotiation auto crossover and auto polarity Fiber optic port speed 100BaseFX Fiber optic wavelength 1300 nm al I Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters Safety Standards These industrial Ethernet Switches me
20. hese industrial Ethernet switches and media converters can be snapped onto a standard 35 mm x 7 5 mm height DIN rail Standard CENELEC EN50022 The switches and media converters can be mounted either vertically or horizontally Refer to the mechanical drawings that follow for proper mounting Note Make sure to allow enough room to route your Ethernet copper or fiber optic cables Mounting Removal DIN Rail Mounting DIN rail mounting steps 1 Hook top back of unit over the DIN rail 2 Push bottom back onto the DIN rail until it snaps into place DIN rail removal steps A Insert screwdriver into DIN clip and pry until it releases from the DIN rail B Unhook top of unit from DIN rail Ist Ed Rev C 07 11 St rid User Manual Installation Metal Case Switches Overview These industrial Ethernet switches can be snapped onto a standard 35 mm x 7 5 mm height DIN rail Standard CENELEC EN50022 They can be mounted either vertically or horizontally Refer to the mechanical drawings that follow for proper mounting Note Make sure to allow enough room to route your Ethernet copper or fiber optic cables DIN Rail Mounting Mounting Removal DIN rail mounting steps 1 Hook top back of unit over the DIN rail 2 Push bottom back onto the DIN rail until it snaps into place DIN rail removal steps A Push the unit down to free the bottom of the DIN rail B Rotate the bottom of the unit away fr
21. honer au 770 844 4200 Cette publication s appuie sur l information qui tait disponible au moment de l impression la soci t AutomationDirect nous nous effor ons constamment d am liorer nos produits et services C est pourquoi nous nous r servons le droit d apporter des modifications aux produits ou aux publications en tout temps sans pr avis ni quelque obligation que ce soit La pr sente publication peut aussi porter sur des caract ristiques susceptibles de ne pas tre offertes dans certaines versions r vis es du produit Marques de commerce La pr sente publication peut contenir des r f rences des produits fabriqu s ou offerts par d autres entreprises Les d signations des produits et des entreprises peuvent tre des marques de commerce et appartiennent exclusivement leurs propri taires respectifs AutomationDirect nie tout int r t dans les autres marques et d signations Copyright 2007 2011 AutomationDirect com Incorporated Tous droits r serv s Nulle partie de ce manuel ne doit tre copi e reproduite ou transmise de quelque fa on que ce soit sans le consentement pr alable crit de la soci t AutomationDirect com Incorporated AutomationDirect conserve les droits exclusifs l gard de tous les renseignements contenus dans le pr sent document Stride Industrial Unmanaged Ethernet Switches and Media Converters USER MANUAL WAUTOMATIONDIRECT Please include the User Manual Number and
22. l Ett i link and integrated i speed LEDs into a single are multi color integrated LED They are into the labeled for RJ45 ports each port number J See the ACT LNK and Speed 10 100 LED See the ACT LNK Speed LED explanation Power LED There is one power LED that is ON if either power input P1 or P2 has power applied to it ACT LNK LED This is the Yellow LED on Models SE SW5U and SE MC2U with a yellow and a green LED per RJ45 port ON yellow Indicates that there is a proper Ethernet connection Link between the port and another not flashing Ethernet device but no communications activity is detected ON yellow Indicates that there is a proper Ethernet connection Link between the port and another flashing Ethernet device and that there is communications activity Indicates that there is not a proper Ethernet connection Link between the port and OFF o a device Make sure the cable has been plugged securely into the ports at both ends Explanation of LED Indicators continued on next page Ist Ed Rev C 07 11 7 St rid User Manual Speed 10 100 LED This is the Green LED on Models SE SW5U and SE MC2U with two LEDs per RJ45 port ON green A 100 Mbps 100BaseT connection is detected OFF ACT LNK Speed LED A 10 Mbps 10BaseT connection is detected This is a bi color Green Yellow LED on Models SE SW8U and SE SW9U with one LED per RJ45 port
23. om the DIN rail C Unhook top of unit from DIN rail 10 Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters Mounting Options Stride switches with metal cases offer the following optional mounting methods F i A Vertical DIN rail mount This mounting option allows for quickest installation and optimal utilization of rail space B Vertical screw to panel mount This mounting option gives better shock and vibration resistance C Flat screw to panel mount This mounting option offers a low profile orientation in shallow boxes plus the best shock and vibration resistance The power connection terminal block is removable for access to the mounting tab Important Notes about Thermal Performance Stride switches with metal cases use an innovative technique to remove excess heat from the product and its components This technique effectively utilizes the heavy gauge all aluminum case as a large heat sink Therefore the case may be warm during operation especially with heavy loads such as all ports linked and active This is normal operation For best performance it is recommended that a DIN rail spacer such as end clamp part number DN EB35 be used between the switch and any adjacent device This will leave an air gap for best heat dissipation off the case For best thermal performance when direct panel mounting to a metal surface thermal compound may be used between the switch and moun
24. or direct 100 6 panel mounting o a flat surface 50 3 T1 1 00 so gt 82 8 1 5 Mechanical Dimensions for 5 and 8 Port Models in Metal Case Inches mm 5 or 8 Port SE SW5U WT SE SW8U WT Removable 0 30 Snaps to standard 0 175 oo 7 6 35 mm x 7 5 mm height pansa 44 Cem DIN rail EN50022 y 2 25 Dia 0 175 4 4 57 1 Use for direct panel mounting to 4 a flat surface with 114 3 up to 8 screw Removable 2 25 for direct panel 57 1 mounting Ml _ 0 39 40 6 76 2 9 9 8 Port Ist Ed Rev C 07 11 I 13 St rid User Manual Mechanical Dimensions for 5 and 9 Port models with Fiber in Metal Case Inches mm SE SW5U ST WT SE SW5U SC WT SE SW9U ST WT and SE SW9U SC WT Removable Screw Block Snaps to standard Phoenix 0 40 0 30 9355 mm x 7 5 mm height 0 175 p n 1757035 10 2 7 6 DIN rail EN50022 T 4 4 O fll e a JN 2 25 57 1 Dia 0 175 4 4 Use for direct panel mounting to 4 00 a flat surface with 101 6 up to 8 screw Removable for direct panel mounting 0 55 14 0 1 10 27 9 40 6 5 Port 9 Port 14 I Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters mm Wh Power Wiring Overview The industrial Ethernet switches and media converters can be powered from the same DC source that is used to power your other devices To
25. rovides you with important information for installation connectivity and setup The manual shows you how to install wire and use the products Technical Support We strive to make our manuals the best in the industry We rely on your feedback to let us know if we are reaching our goal If you cannot find the solution to your particular application or if for any reason you need technical assistance please call us at 770 844 4200 Our technical support group will work with you to answer your questions They are available Monday through Friday from 9 00 A M to 6 00 P M Eastern Time We also encourage you to visit our web site where you can find technical and non technical information about our products and our company http www automationdirect com If you have a comment question or suggestion about any of our products services or manuals please let us know Conventions Used 2 When you see the notepad icon in the left hand margin the paragraph to its immediate right will be a special note The word NOTE in boldface will mark the beginning of the text When you see the exclamation mark icon in the left hand margin the paragraph to its immediate right will be a warning This information could prevent injury loss of property or even death in extreme cases The word WARNING in boldface will mark the beginning of the text I Ist Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Convert
26. stance Fiber Ports 100BaseFX ports 100 meters Fiber Ports 100BaseFX multimode 1 Fiber port mode Multimode mm Fiber port connector ST models SE ST and SE ST WT SC models SE SC and SE SC WT Optimal fiber cable 90 125 or 62 5 125 um Center wavelength 1300 nm Fiber ports continued on the next page Ist Ed Rev C 07 11 I 19 St rid User Manual Technical Specifications cont d Fiber Ports contd Fiber Ports 100BaseFX multimode cont d Links up to 4 km typ 1300 nm use with 50 or 62 5 125 um fiber Multimode gt Transmitter power dB 21 min 17 typ 14 max gt Receiver sensitivity dB 34 typ 31 max Nominal max distance 4 km full duplex Half and full duplex Full duplex Ethernet compliance 100BaseFX Eye safety laser IEC 60825 1 Class 1 FDA 21 CFR 1040 10 and 1040 11 General Specifications General Specifications Ethernet switch type Up to 9 ports Operating mode Store amp forward wire speed switching non blocking Devices supported All IEEE 802 3 compliant devices are supported Standards IEEE 802 3 802 3u 802 3x MAC addresses 1024 addresses Memory bandwidth 3 2 Gbps Latency for 10 Mbps ports 16 us frame time typical Latency for 100 Mbps ports 5 us frame time typical Power input Redundant Input Terminals H port WASAN a Uae ST and SE MC2U SC Input pow
27. t there is a transmit TX and receive RX signal When making the fiber optic connections make sure that the transmit TX port of the switch connects to the receive RX port of the other device and the receive RX port of the switch connects to the transmit TX port of the other device Use standard fiber optic wiring techniques not covered by this manual to make your connections The corresponding ACT LNK LED will be ON solid when you have made a proper connection See images below for typical fiber optic port placement Fiber Ports on Switches Ist Ed Rev C 07 11 17 St rid User Manual Duplex Operation Network Device Check The RJ45 ports will auto sense for Full or Half duplex operation while the fiber ports are configured for full duplex operation Note Fiber devices with half duplex settings will communicate with the switch in most situations The industrial Ethernet switches and media converters support 10 100BaseT on the RJ45 copper ports and 100BaseFX on the fiber optic ports Make sure you connect the appropriate devices to each port Note The following AutomationDirect PLC Ethernet Modules are not compatible with the Stride Ethernet Switches and Media Converters with fiber optic connections because the modules have a speed of 10BaseF fiber optic only Ethernet Communications Module p n H2 ECOM F amp H4 ECOM F Ethernet Base Controller Module p n H2 EBC F amp H4 EBC F Ethernet Remote
28. table for your particular application nor do we assume any responsibility for your product design installation or operation Our products are not fault tolerant and are not designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of the product could lead directly to death personal injury or severe physical or environmental damage High Risk Activities AutomationDirect specifically disclaims any expressed or implied warranty of fitness for High Risk Activities For additional warranty and safety information see the Terms and Conditions section of our catalog If you have any questions concerning the installation or operation of this equipment or if you need additional information please call us at 770 844 4200 This publication is based on information that was available at the time it was printed At AutomationDirect we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product This publication may contain references to products produced
29. ting surface This will reduce any air gaps and optimize the transfer of heat from the case to the mounting surface Ist Ed Rev C 07 11 11 St rid User Manual Mechanical Dimensions for 5 and 8 Port Models in Plastic Case Inches mm 5 or 8 Port SE SW5U 8 SE SW8U Removable Screw Block Ph p n 1757035 Snaps to standard 35 mm x 7 5 mm height DIN rail EN50022 O O o 25 7 1 98 4 20 Dia 0 15 3 8 106 7 D D c for se 3 95 100 3 panel mounting o a flat surface J IL Poll a JD IEY 1 00 7 1 50 Mm Eo 3 26 0 06 25 4 38 1 82 8 1 5 5 Port 8 Port Mechanical Dimensions for 5 and 9 Dort Models with Fiber in Plastic Case Inches mm SE SW5U ST SE SW5U SC SE SW9U ST and SE SW9U SC Removable Screw Block Phoenix p n 1757035 Snaps to standard 35 mm x 7 5 mm height DIN rail EN50022 4 35 Dia 0 15 3 8 110 5 Use for direct panel mounting o a flat surface 3 96 100 6 1 00 x 25 4 38 1 5 Port 9 Port 12 1st Ed Rev C 07 11 Industrial Unmanaged Ethernet Switches amp Media Converters Mechanical Dimensions for 2 Port Media Converter in Plastic Case Inches mm Media Converters SE MC2U ST and SE MC2U SC Removable Screw Block Phoenix 0 40 Snaps to standard p n 1757035 35 mm x 7 5 mm height Y DIN rail EN50022 50 3 Dia 0 15 3 8 3 96 Use f

Download Pdf Manuals

image

Related Search

Related Contents

Sem título-1  MANUAL DE MONTAGEM PLATAFORMAS    American Standard Acrylux Framed By-Pass Shower User's Manual  1. Product Description 2. Product Overview 3. Charging  Hamilton Beach 68120 User's Manual  Tripp Lite HCRK-3 User's Manual  Bosch 2609256A21  Camaraderie n°300 BD - Fédération Nationale des Francas  Time - Race Timer  