Home
IBM TotalStorage DS300 and DS400 Quick Installation Guide
Contents
1. IBM TotalStorage DS300 and DS400 Quick Installation Guide Before using this information and the product it supports read the IBM Statement of Limited Warranty in the IBM Machine Types 1700 and 1701 Warranty and Support Information document on the IBM Documentation CD Obtaining the documentation from the IBM Support Web site All IBM TotalStorage documentation that is referred to in this Quick Installation Guide is on the IBM Documentation CD that comes with the storage subsystem The storage subsystem might have features that are not described in the documentation that you received with the unit The documentation might be updated occasionally to include information about those features or technical updates might be available to provide additional information that is not included in the storage subsystem documentation These updates are available from the IBM Web site To check for updated documentation and technical updates complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www ibm com servers storage support 2 On the Support for TotalStorage products page under Select your product in the Product family field select Disk storage systems 3 In the Product field select DS300 Disk System or DS400 Disk System 4 Click Go 5 Under Technical resources select Documentation Befo
2. www ibm com ibm environment products prp shtml Notice This mark applies only to countries within the European Union EU and Norway This appliance is labeled in accordance with European Directive 2002 96 EC concerning waste electrical and electronic equipment WEEE The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Directive 3B IOI Id EU GHB KV WO LHILEWTCOABAENET x Oa IIL EU ENC HT 4 Be EA E T ae te 4 2002 96 EC WEEE O F AVA SIC WET COPA EU MRICS OHARA AROMM EU IVOR FEED TW ET LOAM MARI o MICH TIC GEO CIE Le TOMER HALLE MSC HATE OICM ORM MICH SV CWEF Remarque Cette marque s applique uniquement aux pays de l Union Europ enne et a la Norv ge L etiquette du syst me respecte la Directive europ enne 2002 96 EC en mati re de D chets des Equipements Electriques et Electroniques DEEE qui d termine les dispositions de retour et de recyclage applicables aux syst mes utilis s travers l Union europ enne Conform ment la directive ladite tiquette pr cise que le produit sur lequel elle est appos e ne doit pas tre jet mais tre r cup r en fin de vie In accordance with the European WEEE Directive
3. click Next Select the logical drive name size and preferred controller that you want then if you are finished click Next If you want to create more than one logical drive or change the preferred controller complete the following steps see the Creating logical drives section in the ServeRAID Manager online help for more information Change the default size to less than the full capacity Select the preferred controller from the Controller menu Click Create new logical drive at the bottom of the pane ao 5p Select the next logical drive name and size e When you have selected all the names and sizes that you want click Next For a TotalStorage DS400 continue to step 7 otherwise select the authentication options for the logical drive To configure the access control list for the logical drive complete the following steps see Defining initiator information in the ServeRAID Manager online help for more information a Select Add or Discover new initiators DS400 only A window opens containing the first entry in the access control list b If you selected Discover new initiators in the top line in the window type or select from the menu one of the following choices e The worldwide port name WWPN for the Fibre Channel host bus adapter HBA that the logical unit number LUN will be bound to e The iSCSI Qualified Name IQN for the iSCSI initiator c In the second line in the window type the al
4. derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 11 Taiwanese Class A warning statement a ERNA 2 PE Ae oe gt FE Fe AE WY BR EP AB A AF gt FY AGL Se RAMA Pa gt Hs AIF o AA SRE RAR KLM FON Ro Chinese Class A warning statement kA A PE e RMB iZF Go A RESIS RTCA BF HL FHA A RE we se H AT Ft AL SE YT AFB te Japanese Voluntary Control Council for Interference VCCI statement CORBIS fA PULSE SS RMS BF Ril hae VCCI D I BO lt AE ae os gull RECT CORE TAERA CHAT EERIE BSR CT CEMHVES COMAIMISHAAMBICMRE BT SKIER ENECEMHVYVEF Seventh Edition December 2005 Printed in Singapore Copyright International Business Machines Corporation 2005 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp 1P P N 31R1617
5. and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformit la r glementation d Industrie Canada Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Australia and New Zealand Class A statement Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures United Kingdom telecommunications safety requirement Notice to Customers This apparatus is approved under approval number NS G 1234 J 100003 for indirect connection to public telecommunication systems in the United Kingdom European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product including the fitting of non IBM option cards This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were
6. electrical and electronic equipment EEE is to be collected separately and to be reused recycled or recovered at end of life Users of EEE with the WEEE marking per Annex IV of the WEEE Directive as shown above must not dispose of end of life EEE as unsorted municipal waste but use the collection framework available to customers for the return recycling and recovery of WEEE Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE For proper collection and treatment contact your local IBM representative Battery return program This product may contain a sealed lead acid nickel cadmium nickel metal hydride lithium or lithium ion battery Consult your user manual or service manual for specific battery information The battery must be recycled or disposed of properly Recycling facilities may not be available in your area For information on disposal of batteries outside the United States go to http www ibm com ibm environment products batteryrecycle shtml or contact your local waste disposal facility In the United States IBM has established a return process for reuse recycling or proper disposal of used IBM sealed lead acid nickel cadmium nickel metal hydride and battery packs from IBM equipment For information on proper disposal of these batteries contact IBM at 1 800 426 4333 Have the IBM part number listed
7. must open a Telnet session to the new IP address Installing the IBM ServeRAID Manager and Management Station programs and adding a ServeRAID agent To install the IBM ServeRAID Manager and Management Station programs and add a ServeRAID agent for the storage subsystem complete the following steps Install the ServeRAID Manager program on the management station using the ServeRAID Application CD that comes with the DS300 or DS400 storage subsystem see Chapter 1 of the IBM TotalStorage DS300 and DS400 Software Installation Guide for instructions 2 Install the Management Station program on the management station see Chapter 1 of the Software Installation Guide for instructions 3 Start the ServeRAID Manager program then complete the following steps to add a management station object and a ServeRAID agent for the storage subsystem a To add a management station object right click Networked Storage in the ServeRAID Manager interface then select Add Management Station see Adding a remote system object in the ServeRAID Manager online help for more information about adding a management station b To add a ServeRAID agent right click the management station object in the interface and select Add agent Use the IP address that you assigned to the storage subsystem in step 4 on page 2 See Adding a Management Station Agent Object in the ServeRAID Manager online help for more information about adding an agent No
8. parameter help Display the current parameter values If a parameter has a default value the prompt displays the value in square brackets Some parameters require an arbitrary string in which case the commands back and abort cannot be used In these cases enclose the string in quotation marks Use the following information to assign values for the parameters hostname Enter the name that you want to use for the system Enter back to repeat this prompt domain name Enter the domain to which the system belongs SAN name Enter the Storage Area Network SAN to which the system belongs timezone Enter the system time zone system date Enter the system date in the format hh mm dd mm vyy define administrator password Define whether an administrator password is required If a password is required you are prompted for that password which you must enter twice Press Ctrl to leave the password unchanged Press Enter twice to not require an administrator password define operator password Define whether an operator password is required default gateway Enter the name or IP address of a router to which packets are sent if their destinations do not have routes that are defined in the system Enter no to clear the default gateway DNS servers Enter the IP addresses of up to three systems that will act as DNS servers Enter no to clear the list of DNS servers dhcp Enter yes if a DHCP server will be used to disc
9. Guide Important If you want to use the IBM ServeRAID Manager program to manage the DS300 or DS400 storage subsystem make sure that an Ethernet cable is connected to the management port on each controller Turn on the storage subsystem see Turning the storage subsystem on and off in Chapter 9 of the Hardware Installation and User s Guide for instructions Setting the controller defaults To set up the RAID controller defaults complete the following steps 1 w After turning on the storage subsystem wait until the green controller ready LED is lit then from a management station open a Telnet session to IP address 192 168 70 123 For the location and a description of the LED see the storage subsystem rear view section in Chapter 4 for DS300 or Chapter 8 for DS400 of the Hardware Installation and User s Guide Change to administrator mode by typing administrator admin or ad and pressing Enter When prompted for a password enter passwOrd all lowercase letters with a zero not O in passwOrd For Controller A only At the DS300 or DS400 prompt enter setup The Setup wizard prompts you to enter the values for the parameters that are required to configure the system to connect to a local network You can also use the three commands that are described in the following table Table 1 Setup wizard commands Command Function abort Quit the Setup wizard without saving changes back Go to the previous
10. dress for IBM IntelliStation information is http www ibm com intellistation You can find service information for IBM systems and optional devices at http www ibm com support Software service and support Through IBM Support Line you can get telephone assistance for a fee with usage configuration and software problems with xSeries servers BladeCenter products IntelliStation workstations and appliances For information about which products are supported by Support Line in your country or region see http www ibm com services sl products For more information about Support Line and other IBM services see http www ibm com services or see http www ibm com planetwide for support telephone numbers In the U S and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through IBM Services or through your IBM reseller if your reseller is authorized by IBM to provide warranty service See http www ibm com planetwide for support telephone numbers or in the U S and Canada call 1 800 IBM SERV 1 800 426 7378 In the U S and Canada hardware service and support is available 24 hours a day 7 days a week In the U K these services are available Monday through Friday from 9 a m to 6 p m Notices This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this documen
11. f the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Trademarks The following terms are trademarks of International Business Machines Corporation in the United States other countries or both BladeCenter IBM logo TotalStorage e business logo IntelliStation xSeries server ServeRAID IBM ServerProven Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both Linux is a trademark of Linus Torvalds in the United States other countries or both Red Hat the Red Hat Shadow Man logo and all Red Hat based trademarks and logos are trademarks or registered trademarks of Red Hat Inc in the United States and other countries Other company product or service names may be trademarks or service marks of others Important notes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB stands fo
12. hat you want to use for that port and netmask is the management network subnet address See the IBM TotalStorage DS300 Problem Determination Guide or IBM TotalStorage DS400 Problem Determination Guide on the IBM Support Web site for a list of all the available commands 5 Enter save to save the modified settings Configuring the RAID device in ServeRAID Manager To create a RAID array and configure the access control list for the logical drive complete the following steps 1 In the ServeRAID Manager interface on the management station in the right pane click the agent Installing the IBM ServeRAID Manager and Management Station programs and adding a ServeRAID ag The interface displays the Enclosure View pane for the storage subsystem 2 In the upper right corner of the Enclosure View pane click the disk icon The array configuration menu is displayed In the array configuration menu select Create logical drive in a new array then click Next To select the drives that you want in the array see the Creating arrays and hot spare drives section in the ServeRAID Manager online help for more information complete the following steps a Press Ctrl and click each drive that you want in the array b Click the single arrow to move the drives to the left pane c If you want to create more than one array click Create New Array at the top of the left pane and repeat steps 4a and d When you are finished
13. ias that you want to use for the entity in the top line d Click OK to accept the information that you entered A new access list entry window opens Repeat steps 75 through 7d for each entry in the access list When you are finished click Cancel Click Next The mapping pane is displayed The aliases in the access control list are displayed in tabs in the right pane the logical drives are displayed in the left pane Complete the following steps to associate one or more logical drives with an alias see Assigning logical drives to initiators in the ServeRAID Manager online help for more information a Highlight the logical drive b Click the alias that you want to associate it with c Click the single arrow in the middle pane to move the drive to the alias or click the double arrow in the middle pane to move all the drives to the alias The drive moves to a point beneath the alias in the right pane d Click Next e Click Accept to apply the changes or click Back to return to the mapping pane to make changes or to make more associations After you complete the associations the Enclosure View pane is displayed again and the LUN is ready for access Getting help and technical assistance If you need help service or technical assistance or just want more information about IBM products you will find a wide variety of sources available from IBM to assist you This appendix contains information about where to go fo
14. on the battery available prior to your call In the Netherlands the following applies For Taiwan Please recycle batteries v4 HEE ea DK 10 Electronic emission notices Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference
15. over the system network values Enter no if a DHCP server will not be used If you enter yes the wizard takes you to the finish parameter If you enter no the wizard continues to prompt you for information about the main Ethernet interface of the system IP address Enter the IP address in x x x x format You can also define the netmask by typing its width after the IP address Note For the DS300 storage subsystem the management interface must be in a separate network segment from your iSCSI ports netmask Define the size of the netmask Any of the common formats are accepted Note If you entered the netmask as part of the IP address in the previous prompt this parameter is skipped broadcast address Enter the address to be used for broadcasts Any of the common formats are accepted peer IP address Enter the IP address for the peer controller in x x x format Note For the DS300 storage subsystem the management interface must be in a separate network segment from your iSCSI ports peer netmask Define the size of the netmask for the peer controller Any of the common formats are accepted peer broadcast address Enter the address to use by the peer controller for broadcasts Any of the common formats are accepted finish Enter yes to apply the values that you have entered or enter no to return to the first parameter and change the values that you have entered Note If you changed the management IP address in step you
16. r 1 000 000 000 bytes Total user accessible capacity may vary depending on operating environments Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM Maximum memory may require replacement of the standard memory with an optional memory module IBM makes no representation or warranties regarding non IBM products and services that are ServerProven including but not limited to the implied warranties of merchantability and fitness for a particular purpose These products are offered and warranted solely by third parties IBM makes no representations or warranties with respect to non IBM products Support if any for the non IBM products is provided by the third party not IBM Some software may differ from its retail version if available and may not include user manuals or all program functionality Product recycling and disposal This unit must be recycled or discarded according to applicable local and national regulations IBM encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed IBM offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products Information on IBM product recycling offerings can be found on IBM s Internet site at http
17. r additional information about IBM and IBM products what to do if you experience a problem with your server or IntelliStation system or optional device and whom to call for service if it is necessary Before you call Before you call make sure that you have taken these steps to try to solve the problem yourself e Check all cables to make sure that they are connected e Check the power switches to make sure that the system and any optional devices are turned on e Use the troubleshooting information in your system documentation and use the diagnostic tools that come with your system Information about diagnostic tools is in the Hardware Maintenance Manual and Troubleshooting Guide or Problem Determination and Service Guide on the IBM Documentation CD that comes with your system Note For some server options the Hardware Maintenance Manual and Troubleshooting Guide is available only from the IBM support Web site e Go to the IBM support Web site at http www ibm com support to check for technical information hints tips and new device drivers or to submit a request for information You can solve many problems without outside assistance by following the troubleshooting procedures that IBM provides in the online help or in the documentation that is provided with your IBM product The documentation that comes with server and IntelliStation systems also describes the diagnostic tests that you can perform Most server and IntelliSta
18. re you begin you should have a plan for how you want to install this storage subsystem into a storage network This plan should allow for the data servers management station host bus adapters switches and other equipment See Chapter 2 for TotalStorage DS300 or Chapter 5 for TotalStorage DS400 in the IBM TotalStorage DS300 and DS400 Hardware Installation and User s Guide for more information Installing the hardware To install the hardware complete the following steps 1 Remove all packing materials 2 Install the rails and the DS300 or DS400 storage subsystem into a standard EIA 19 inch rack see the printed Rack Installation Instructions document that comes with the storage subsystem for instructions 3 Install the front bezel on the DS300 or DS400 storage subsystem see Chapter 10 of the Hardware Installation and User s Guide for instructions 4 Install hard disk drives in the DS300 or DS400 storage subsystem see Chapter 10 of the Hardware Installation and User s Guide for instructions 5 Connect the power cables that come with the DS300 or DS400 storage subsystem to the power distribution unit see Power cabling in Chapter 9 of the Hardware Installation and User s Guide for instructions 6 Install the small form factor pluggable SFP modules and connect the Ethernet and Fibre Channel cables For instructions see Chapter 3 for DS300 or Chapter 7 for DS400 of the Hardware Installation and User s
19. t in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product program or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions o
20. te Enter the IP address of controller A or controller B Only one controller must be added as a ServeRAID agent Installing the controller firmware The RAID controller firmware is updated occasionally to improve the function or performance of the RAID controller in the storage subsystem Obtain the latest firmware before proceeding to the next steps see the Software Installation Guide for information about how to locate and download the latest firmware Setting IP addresses for DS300 iSCSI ports To set the IP addresses for the iSCSI ports on the DS300 storage subsystem complete the following steps 1 Open a Telnet session to controller_A using either the default IP address 192 168 70 123 or the IP address that you assigned in step 2 Log in as administrator using either the default password passwOrd or the password that you defined in step 3 To set the IP address for iSCSI port eth2 enter the following commands interface manage eth2 x ip IPaddress interface manage eth2 x netmask netmask interface manage eth2 x broadcast broadcast where x is the controller Paddress is the IP address that you want to use for that port and netmask is the management network subnet address 4 To set the IP address for iSCSI port eth3 enter the following commands interface manage eth3 x ip IPaddress interface manage eth3 x netmask netmask interface manage eth3 x broadcast broadcast where x is the controller Paddress is the IP address t
21. tion systems operating systems and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes If you suspect a software problem see the documentation for the operating system or program Using the documentation Information about your IBM server or IntelliStation system and preinstalled software if any or optional device is available in the documentation that comes with the product That documentation can include printed documents online documents readme files and help files See the troubleshooting information in your system documentation for instructions for using the diagnostic programs The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates To access these pages go to http www ibm com support and follow the instructions Also some documents are available through the IBM Publications Center at http www ibm com shop publications order Getting help and information from the World Wide Web On the World Wide Web the IBM Web site has up to date information about IBM server and IntelliStation systems optional devices services and support The address for IBM xSeries and BladeCenter information is http www ibm com eserver xseries The ad