Home
- BCF Technology
Contents
1. FL Femur Length BPD Biparietal Diameter AC Abdominal Circumference HC Head Circumference APTD x TTD Anterior Posterior Trunk Diameter by Transverse Trunk Diameter LV Length of Vertebra FTA Fetal Trunk Cross sectional Area HL Humerus Length BD Binocular Distance FT Foot Length OFD Occipital Frontal Diameter TAD Transverse Abdominal Diameter TCD Transverse Cerebellum Diameter THD Thorax Transverse Diameter TIB Tibia Length ULNA Ulna Length Estimated Fetal Weight EFW by AC BPD AC BPD FL AC BPD FL HC AC FL AC FL HC AC HC e Calculations and Ratios FL BPD FL AC FL HC HC AC CI Cephalic Index AFI Amniotic Fluid Index e Measurements Calculations by Jeanty Merz Tokyo University Mercer Hansmann Erickson Hill Shephard Hadlock Hohler Campbell e Fetal Graphical Trending e Growth Percentiles e Multi Gestational Calculations 4 e Fetal Qualitative Description Anatomical survey e Fetal Environmental Description Biophysical profile e Programmable OB Tables e Over 20 selectable OB Calcs Expanded Worksheets GYN Measurements Calculations e Right Ovary Length Width Height Left Ovary Length Width Height e Uterus Length Width Height e Ovarian Volume e ENDO Endometrial thickness e Ovarian RI LOGIQ 7 Product Data Sheet e Uterine RI Follicular measurements e Summa
2. 11 0 MHz FOV Max 90 Doppler Frequency 5 0 MHz Number of Element 128 Physical Foot Print 14 x 11 mm Steered Angle 5 10 15 20 Convex Radius 11 mmR B mode Imaging Frequency 7 0 8 0 Biopsy Guide Available Not FOV Max 133 10 0 MHz Available Physical Foot Print 23 x 10 mm Doppler Frequency 5 0 6 7 MHz e 6T Wide Band Multiplane B mode Imaging Frequency 6 0 8 0 CW Doppler Frequency 5 0 MHz Transesophageal Phased Array Sector 10 0 MHz Biopsy Guide Available None Probe Harmonic Frequency 8 0 10 0 MHz 7L Wide Band Linear Probe Applications Cardiac Doppler Frequency 4 0 5 0 MHz Applications Vascular Small Parts Probe Band Width 4 0 10 0 MHz Biopsy Guide Available None Probe Band Width 3 0 8 0 MHz Number of Element 64 e M3S Matrix Array Wide Band Phased Number of Element 192 FOV Max 90 Array Sector Probe FOV Max 46 mm B mode Imaging Frequency 4 0 5 0 Applications Cardiac Transcranial Physical Foot Print 52 x 11 mm 6 0 MHz Abdomen B mode Imaging Frequency 4 0 6 0 Harmonic Frequency 6 0 MHz Probe Band Width 1 5 4 2 MHz 7 0 MHz Doppler Frequency 4 0 5 0 MHz Number of Element 192 Harmonic Frequency 6 0 8 0 MHz CW Doppler Frequency 5 0 MHz FOV Max 90 Doppler Frequency 4 0 5 0 MHz Biopsy Guide Available None Physical Foot Print 23 x 16 mm Steered Angle 0 5 10 15
3. 640MB with Extended Cine Memory option Dual Image CINE Display Quad Image CINE Display e CINE Gauge and CINE Image Number Display e CINE Review Loop e CINE Review Speed 9 types 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 e Selectable CINE Sequence for CINE Review e Measurements Calculations and Annotations on CINE Playback e Scrolling Timeline Memory e Digital Continuous CINE Capture over 180 sec option Image Storage e On board database of patient information from past exams e Storage Format DICOM Raw Data e DICOM Still Image Storage Size Gray Image 300K to 1 3 MB Color Image 900K to 1 9 MB e Multiframe e Display Format Full size 4x4 and thumbnails e Live image and stored image side by side display e MO Disk Storage 128 230 540 640 MB or 1 3 GB e CD R storage 650 700 MB DVD storage R 4 7GB and RAM 9 4GB Double sided Cartridge Non cartridge e Conversion to JPEG AVI and WMV file formats e Hard Drive Image Storage 60 GB Connectivity Ethernet network connection e RS 232 serial data output need a converter cable e DICOM 3 0 option Verify Print Store Modality Worklist Storage Commitment Modality Performed Procedure Step MPPS Media Exchange Off network mobile storage queue Query Retrieve supported on Centricity and other compatible vendors Structured Reporting compatible with LOGIQworks Public SR Template Media St
4. 7S 6T B Flow option e Available on 10L M12L 7L 3 5C 3 5CS and T739 Probes e Background On Off e Sensitivity PRI 14 steps e Line Density 4 steps e Edge Enhance 6 steps e Frame Average 8 steps e Gray Scale Map 23 types e Dynamic Range 30 120 dB 3 dB step LOGIQ 7 Product Data Sheet e Rejection 6 steps e Gain 0 98 dB 2 dB step e Auto Line Density On Off pre settable Dual Beam On Off pre settable e B Flow Color e Accumulation 6 steps Coded Contrast Imaging option e Coded Harmonic Angio Available on 3 5C 3 5CS M3S 3S and 7L 10L probes Tissue Background Selection 4 steps TruAgent Detection Available on 3 5C 3 5CS M3S 3S and 7L 10L probes 2 frequencies on 3 5C and 3 5CS 1 on M3S 3S 7L and 10L e Coded Phase Inversion 2 types Available on 3 5C 3 5CS M38 3S and 7L probes Tissue Background Selection 4 steps TAD PI Coded Phase Inversion Color Available on 3 5C and 3 5CS e Max Enhancement On Off e Gray Scale Map 21 types e Contrast Clock Display e Time Trigger Scan 0 3 amp 0 5 10 sec 0 5 sec step e Time Intensity Curve Analysis e Accumulation 6 steps e SRI LOGIQView option e Available on all probes Extended Field of View Imaging e For use in B Mode e LOGIQView Status e Auto detection of scan direction e Pre or post process zoom up to 10X e Rotation e Auto best fit on monitor e Measurements in B Mode Up to 60 cm
5. 4 e Accumulation 6 steps Power Doppler Imaging e PDI Map 13 types e CF PDI Flash Suppression 2 steps e CF PDI Focus Depth default pre settable for 0 100 of ROI in depth 10 step e CF PDI Acoustic Output 0 100 10 step e CF PDI Angle Steer 0 20 e Packet Size 5 16 dependent on probe application e Spatial Filter 6 steps e Frame Average 7 steps e PRF 280 Hz 19600 Hz e Power Threshold 0 100 5 step e Arbitration Threshold 15 steps pre settable e Gain 0 40 dB 0 5 dB step e Wall Filter 7 steps depend on probe application e CF PDI Frequency Up to 2 steps depend on probe e Auto Line Density On Off pre settable e Transparent 5 steps Invert On Off e Accumulation 6 steps M Mode e Sweep Speed 8 steps e M Color 8 types e M PW Display Format V 1 3B V 1 2B V 2 3B H 1 2B H 1 4B TLOnly e B M Acoustic Output 0 100 2 step e Rejection 6 steps e Dynamic Range 30 120 dB 3 dB step e Edge Enhance 6 steps e Gray Scale Map 23 types e M Gain 0 98 dB 2 dB step Anatomical M Mode e M mode cursor adjustable at any plane e Can be activated from a CINE loop from a live or stored image e Available with Color Flow Mode e M amp A capability PW CW Mode e Maximum and Minimum Velocity Scales Max 10 m sec Min 5 cm sec e Gray Scale Map 4 types e Dynamic Range 24 60 4 dB step e Base Line 5 95 11 steps
6. Interventricular Septum Thickness IVSd IVSs Inferior Vena Cava Pulmonary Artery Diameter MPA Systemic Vein Diameter Systemic Diam Patent Ductus Arterosis Diameter PDA Diam Pericard Effusion PEs Patent Foramen Ovale Diameter PFO Diam Ventricular Septal Defect Diameter VSD Diam Interventricular Septum IVS Fractional Shortening IVSd IVSs e Tricuspid Valve Tricuspid Valve Area TV Panimetry Tricuspid Valve Annulus Diameter TV Annulus Diam M Mode Measurements e Aorta Aortic Root Diameter Ao Root Diam e Aortic Valve Aortic Valve Diameter AV Diam Aortic Valve Cusp Separation AV Cusp Aortic Valve Ejection Time LVET e Left Atrium Left Atrium Diameter to AoRoot Diameter Ratio LA Ao Ratio Left Atrium Diameter LA Diam e Left Ventricle Left Ventricle Volume Teichholz Cubic LVIDd LVI Ds Left Ventricle Internal Diameter LVIDd LVI Ds Left Ventricle Posterior Wall Thickness LVPWd LVPWs Left Ventricle Ejection Time LVET Left Ventricle Pre Ejection Period LVPEP Interventricular Septum IVS Left Ventricle Internal Diameter LVI D Left Ventricle Posterior Wall Thickness LVPW e Mitral Valve E Point to Septum Separation EPSS Mitral Valve Leaflet Separation D E Excursion Mitral Valve Anterior Leaflet Excursion D E Excursion Mitral Valve D E Slope D E Slope Mitral Valve E F Slope E F Slope e Pulmonic Valve Q
7. Quad screen format e Zoom Write Read Pan Colorized Image Colorized B Colorized M Colorized PW Colorized CW option Colorized B Flow option Time line Display Independent Dual B PW Display Display Formats Top Bottom selectable format Size 1 2 1 2 1 3 2 3 2 3 1 3 Side Side selectable format 1 2 1 2 1 3 2 3 0 1 Switchable after freeze e Virtual Convex Page 2 e CrossBeam option e Tissue Velocity Imaging TVI Mode option Display Annotation Patient Name First Last amp Middle name each store 27 characters Up to 27 total characters displayed e Patient ID 31 Characters Up to 27 total characters displayed e Age Sex and Birth Date optional e Hospital Name 23 Characters e Date 2 Types selectable MM DD YY DD MM YY Time 2 types selectable 24 hours 12 hours e Gestational Age from LMP EDD GA BBT e Probe Name e Gray Map names Probe Orientation e Depth Scale Marker e Lateral Scale Marker e Focal Zone Markers e Image Depth Zoom Depth e B Mode Gain Dynamic Range Imaging Frequency Edge Enhance Frame Averaging Gray Map ATO On Off e M Mode Gain Dynamic Range Time Scale Doppler Mode Gain Angle Sample Volume Depth and Width Wall Filter Velocity and or Frequency Scale Spectrum Inversion Time Scale PRF Doppler Frequency e Color Flow Mode Line Density Frame Averaging Packet Size Color Scale Color Velocity R
8. e SV Gate 1 2 3 4 5 6 7 8 9 10 12 14 16 mm e Angle Correct 90 1 step e Spectral Color 5 types e PW Sweep Speed 8 steps Invert On Off e M PW Display Format V 1 3B V 1 2B V 2 3B H 1 2B H 1 4B TLOnly Duplex On Off e PW Acoustic Output 0 100 10 step e Spectral Averaging 5 steps e Time Resolution 4 steps e PW CF Ratio 1 2 4 e Rejection 15 steps e Gain 0 32 dB 1 dB step e Wall Filter 5 1500 Hz 22 steps depend on probe application e PW Angle Steer 0 5 10 15 20 e PRF 640 30000 Hz with PW 50000 Hz with CW e Sample Volume Depth 29 steps default pre settable e CW Mode option is Available on the Following Probes M3S 3S 7S 10S 6T Page 4 P2D P6D Coded Harmonic Imaging e Available on the Following Probes 3 5C 3 5CS 3C M7C E8C 8C BE9C M3S 3S 7S M12L 7L 10L il2L T739 6T Softener 4 steps e Line Density 4 steps e Line Density Zoom 4 steps e Suppression 6 steps e Edge Enhance 6 steps e Gray Scale Map 23 types e Gain 0 98 dB 2 dB step Dynamic Range 30 120 dB 3 dB step e Rejection 6 steps e Auto Line Density On Off pre settable e Frequency Up to 5 steps depend on probe Coded Excitation e Available on M7C probe Virtual Convex e Provides a Convex Field of View for Linear and Sector probes e Available on the Following Probes 10L M12L 7L 10S il2L T739 M3S
9. 7 MHz Steered Angle 5 10 15 20 Biopsy Guide Available None e P2D Non imaging Single CW Doppler Pencil Probe Applications Cardiac Frequnsy 2 0 MHz e P6D Non imaging Single CW Doppler Pencil Probe Applications Cardiac Vascular Pediatric Frequnsy 5 0 MHz e Probe Adapter Pencil Probe Adapter PPA for P2D and P6D probes Inputs and Outputs e Video In S Video e Video Out RGB VGA Composite Color Composite B W 2 S Video e Audio Stereo Out e Audio Stereo In e External Microphone In e Connectors Remote for B W Printer Remote for Color Printer or Camera Footswitch Ethernet InSite Modem Connection Option Power for Peripherals 5 LOGIQ 7 Product Data Sheet Safety Conformance The LOGIQ 7 is e Listed to UL 2601 1 by a Nationally Recognized Test Lab Certified to CSA 22 2 60601 1 by an SCC accredited Test Lab e CE Marked to Council Directive 93 42 EEC on Medical Devices e Conforms to the following standards for safety EN 60601 1 Electrical medical equipment EN 60601 1 1 Electrical medical equipment EN 60601 1 2 Electromagnetic compatibility EN 60601 1 4 Programmable medical systems IEC 61157 Declaration of acoustic output EN 60601 2 37 Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment IEC 60601 2 37 Amendment 1 Particular requirements for the safety of ultrasonic medical diagnostic and monitoring
10. Anatomical M Mode option System Standard Features e Sate of the art User Interface with High Resolution 10 4 inch Color LCD Touch Panel e Realtime Triplex Mode at Any Depth and Any PRF e Automatic Optimization Auto Tissue Optimization ATO LOGIQ 7 Product Data Sheet Auto Spectrum Optimization ASO Auto Color Optimization ACO e Coded Harmonic Imaging e Coded Excitation e Virtual Convex e Anatomical M Mode Patient Information Database e Image Archive on CD DVD and Hard Drive e Easy Backup to Media for data security e Easy 3D Freehand acquisition with basic features with 3D Movie e TruAccess Raw Data Processing and Analysis e Realtime Automatic Doppler Calcs e OB Calcs e Fetal Trending e Multi Gestational Calcs e Hip Dysplasia Calcs e Gynecological Calcs e Vascular Calcs e Cardiac Calcs e Urological Calcs e Renal Calcs e InSite Capability e iLing Capability e On board electronic documentation e Standby Mode System Options e LOGIQ View e Advanced 3D with 3D Landscape B Flow and B Flow Color e Coded Contrast Imaging e DICOM 3 0 Connectivity e CrossBeam spatial compounding e Report Writer on board reporting e Stress Echo Package PFD Pulsatile Flow Detection e Speckle Reduction Imaging SRI e VoiceScan e Tissue Velocity Imaging TVT with Curved Anatomical M Mode and Q Analysis e Physio Input Panel for ECG PCG Aux e ECG Cable e PCG microphone e
11. LVIDs LVSd LVSs Left Ventricle Stroke Index Single Plane Four Chamber Method of Disk LVI Dd LVIDs LVSd LVSs Left Ventricle Stroke Index Bi Plane Bullet Method of Disk LVAd LVAs Interventricular Septum IVS Left Ventricle Internal Diameter LVI D Left Ventricle Posterior Wall Thickness LVPW e Mitral Valve Mitral Valve Annulus Diameter MV Ann Diam E Point to Septum Separation EPSS Mitral Valve Area by Pressure Half Time MVA By PHT Mitral Valve Area Planimetry MVA Planimetry e Pulmonic Valve Pulmonic Valve Area PV Planimetry Pulmonic Valve Annulus Diameter PV Annulus Diam Pulmonic Diameter Pulmonic Diam e Right Atrium Right Atrium Diameter Length RAD Ma Right Atrium Diameter Width RAD Mi Right Atrium Area RAA Right Atrium Volume Single Plane Method of Disk RAAd Right Atrium Volume Systolic Single Plane Method of Disk RAAs e Right Ventricle Right Ventricle Outflow Tract Area RVOT Planimetry Left Pulmonary Artery Area LPA Area Right Pulmonary Artery Area RPA Area Right Ventricle Internal Diameter RVIDd RVIDs Right Ventricle Diameter Length RVD Ma Right Ventricle Diameter Width RVD Mi Right Ventricle Wall Thickness RVAWd RVAWSs Right Ventricle Outflow Tract Diameter RVOT Diam Left Pulmonary Artery LPA Main Pulmonary Artery MPA Right Pulmonary Artery RPA e System
12. Mean Square Root Velocity TV Trace Tricuspid Valve Velocity Time Integral TV Trace Tricuspid Valve Time to Peak TV Acc Dec Time Tricuspid Valve Ejection Time TV Acc Dec Time Tricuspid Valve A Wave Duration TV A Dur QRS complex to end of envelope Q to TV close Tricuspid Valve Pressure Half Time TV PHT Stroke Volume by Tricuspid Flow TV Planimetry TV Trace Tricuspid Valve E Peak to A Peak Ratio TV E A Velocity Color Flow Mode Measurements e Aortic Valve Proximal Isovelocity Surface Area Regurgitant Orifice Area AR Radius Proximal Isovelocity Surface Area Radius of Aliased Point AR Radius Proximal Isovelocity Surface Area Regurgitant Flow AR Trace Proximal Isovelocity Surface Area Regurgitant Volume Flow AR Trace Proximal Isovelocity Surface Area Aliased Velocity AR Vmax e Mitral Valve Proximal Isovelocity Surface Area Regurgitant Orifice Area MR Radius Proximal Isovelocity Surface Area Radius of Aliased Point MR Radius Proximal Isovelocity Surface Area Regurgitant Flow MR Trace Proximal Isovelocity Surface Area Regurgitant Volume Flow MR Trace Proximal Isovelocity Surface Area Aliased Velocity MR Vmax Combination Mode Measurements e Aortic Valve Aortic Valve Area Ao Root Diam LVOT Vmax AV Vmax Aortic Valve Area by Continuity Equation by Peak Velocity Ao Root Diam LVOT Vmax AV Vmax Stroke Volume by Aortic Flow AVA
13. Pl ani met ry AV Trace Cardiac Output by Aortic Flow AVA Planimetry AV Trace HR Aortic Valve Area by Continuity Equation VTI Ao Root Diam LVOT Vmax AV Trace e Left Ventricle Cardiac Output Teichholz Cubic LVIDd LVI Ds HR Cardiac Output Two Chamber Single Plane Area Length Method of Disk Simpson LVAd LVAs HR Cardiac Output Four Chamber Single Plane Area Length Method of Disk Simpson LVAd LVAs HR Ejection Fraction Two Chamber Single Plane Area Length Method of Disk Simpson LVAd LVAs Ejection Fraction Four Chamber Single Plane Area Length Method of Disk Simpson LVAd LVAs Left Ventricle Stroke Volume Single Plane Two Chamber Four Chamber Area Length LVAd LVAs Left Ventricle Stroke Volume Single Plane Two Chamber Four Chamber Method of Disk Simpson LVIDd LVIDs LVAd LVAs Left Ventricle Volume Two Chamber Four Chamber Area Length LVAd LVAs Ejection Fraction Bi Plane Method of Disk LVAd LVAs 2CH 4CH Left Ventricle Stroke Volume Bi Plane Method of Disk LVAd LVAs 2CH 4CH Left Ventricle Volume Bi Plane Method of Disk LVAd LVAs 2CH 4CH Left Ventricle Stroke Index Single Plane Two Chamber Four Chamber Area Length LVSd LVSs and BSA Left Ventricle Volume Single Plane Two Chamber Four Chamber Method of Disk LVAd LVAs Left Ventricle Volume Apical View Long Axis Method of Disk LVAd LVAs Stro
14. TV Probe Holder e 3 Pedal Foot Switch with Programmable Functionality Steerable CW Single CW Board e Pencil Probe Adapter Extended Cine Memory Media amp Peripheral Options e Integrated 3 5 inch MO Drive Supports 128 230 520 640 MB or 1 3 GB Disks e Integrated Mounting Kits and Remote Controls Provided for Analog B W thermal printer Analog A6 or A5 Color thermal printer Digital B W thermal printer Digital A6 Color thermal printer Digital A5 Color thermal printer Analog S VHS video cassette recorder DVD video recorder e Video and Audio Connections Provided for Other Devices such as Multi Format Cameras Laser Cameras and Other Peripherals Display Modes e Live and Stored Display Format Full size and split screen both w thumbnails For Still and CINE e Review Image Format 4x4 and thumbnails For Still and CINE e Simultaneous Capability B PW B CFM or PDI B M B CFM M Realtime Triplex Mode B CFM or PDI PW B Flow PW option Dual B B B Dual B CFM or PDI B CW option Realtime Triplex Mode B CFM or PDI CW option B PFD option e Selectable Alternating Modes B M B PW B CFM M B CFM PDD PW B Flow PW option 3D Mode 3D Color Mode option B CW option B CFM PDI CW option B PFD PW option e Multi Image Split Screen Live and or frozen B B CFM or PDI B B PFD option Independent Cine playback
15. Thermal Output 4095 BTU hr with on board peripherals 2390 BTU hr without peripherals Console Design 4 Active Probe Ports Integrated HDD 80GB e Integrated DVD Multi Drive KBD Monitor Up Down Mechanism 180mm adjustable in height e On board Storage for Peripherals Digital B W printer Digital color printer VCR DVD video recorder e Wheels Wheel diameter Front Rear 150 mm 4 rotating flexible wheels with protection cover Integrated locking mechanism that provides rolling lock and caster swivel lock Probe Holders Removable for Cleaning and Washing with Integrated Cable Management e Gel Holder Removable for Cleaning e Air Filters Easily Removable e Rear Storage Cover for Peripheral Connectors and Cables e Rear Handle GE Healthcare Chalfont St Giles Buckinghamshire UK www gehealthcare com User Interface Operator Keyboard Keyboard Width 599 mm 24 in Keyboard Height 785 950 mm 31 37 in adjustable Full Alphanumeric Keyboard e Ergonomic Hard Key Layout e Interactive Back Lighting e Indicator Lights Identify Activated Keys Integrated Recording Keys for Remote Control of Up to 4 Peripheral or DICOM Devices 10 TGC Pods with Re mapping Functionality at Any Depth External Microphone Connecter e Task Light Touch Screen e 26cm 10 4 in High Resolution Color LCD Screen with VGA Format e Interactive Dynamic Software Menu e Brightness Adjustment e User Configurabl
16. on probe application e Spatial Filter 6 steps e Frame Average 7 steps e PRF 280 Hz 19600 Hz e Power Threshold 0 100 5 step e Arbitration Threshold 15 steps pre settable e Gain 0 40 dB 0 5 dB step e Wall Filter 3 steps e CF PDI PFD Frequency Up to 2 steps depend on probe e Auto Line Density On Off pre settable Transparent 5 steps e Invert On Off e Accumulation 6 steps Page 5 SRI option e Speckle Reduction Imaging e Provides 6 levels of speckle reduction e Side by Side Display e Compatible with ALL linear convex and sector transducers e Compatible with ALL scanning mode e Side by Side Display with Non compounding Image TVI option e Myocardial Doppler Imaging with color overlay on tissue image e Available on the sector probes e Tissue color overlay can be removed to show just the 2D image still retaining the tissue velocity information e Curved Anatomical M mode free curved drawing of M mode generated from the cursor independent from the axial plane e Q Analysis Multiple Time Motion trace display from selected points in the myocardium Pre Processing e Write Zoom up to 8x e B M Mode Gain TGC Dynamic Range Acoustic Output Transmission Focus Position Transmission Focus Number Transmission Focus Width Imaging Frequency Edge Enhancement Line Density Control Live Anatomical M mode e PW CW Mode Gain Dynamic Range Acoustic Ou
17. scan length Advanced 3D options e Acquisition of Color data e Automatic rendering e 3D Landscape technology 3D Movie e Main Mode CrossBeam option e Provides Spatial Compounding e Available on the linear and convex probes M12L 10L 7L il2L T739 3 5C 3 5CS M7C 8C E8C BE9C e Provides 3 5 or 7 Angles for Compounding on Linear probes 3 or 5 Angles on Convex probes Side by Side Display with Non compounding Image e Compatible with Coded Harmonic Imaging Stress Echo Package option e Advanced and flexible stress echo examination capabilities e Provides exercise and pharmacological protocol templates 6 default templates Template editor for user configuration of existing templates or creation of new templates e Reference scan display during acquisition for stress level comparison dual screen Baseline level Previous level selectable e Raw data continuous capture Over 180 sec available e Wall motion scoring bulls eye and segmental PFD option e Available on all probes e PFD Map 4 types PFD directional pulsatile 2 types PFD pulsatile non pulsatile 2 types e PFD Type 6 steps e PFD Scale 1 106 3 step e CF PDI PFD Flash Suppression 2 steps e CF PDI PFD Focus Depth default pre settable for 0 100 of ROI in depth 10 step e CF PDI PFD Acoustic Output 0 100 10 step e CF PDI PFD Angle Steer 0 20 e Packet Size 5 16 dependent
18. 20 e BE9C Wide Band Biplane Microconvex B mode Imaging Frequency 2 0 2 5 Biopsy Guide Available Multi Angle Probe 3 0 MHz Reusable Applications Urology Endocavity Harmonic Frequency 3 0 3 2 3 6 4 0 e 10L Wide Band Linear Probe Probe Band Width 4 0 11 0 MHz 4 2 MHz Applications Vascular Small Parts Number of Element 96 x 2 Doppler Frequency 2 0 2 5 MHz Neonatal Pediatrics Convex Radius 9 mmR CW Doppler Frequency 2 0 MHz Probe Band Width 4 0 12 0 MHz FOV Max 126 Biopsy Guide Available Multi Angle Number of Element 192 Physical Foot Print 25 x 9 mm Reusable FOV Max 39 mm B mode Imaging Frequency 6 0 8 0 e 3S Wide Band Phased Array Sector Physical Foot Print 44 x 10 mm 10 0 MHz Probe B mode Imaging Frequency 6 0 8 0 Harmonic Frequency 8 0 10 0 MHz Applications Cardiac Transcranial 10 0 MHz F Dopp ler Frequency 5 0 6 7 MHz Abdomen Harmonic Frequency 8 0 10 0 12 0 Biopsy Guide Available Reusable Probe Band Width 1 5 3 6 MHz MHz stainless steel LOGIQ 7 Product Data Sheet Page 8 e T739 Intraoperative Wide Band Linear Probe Applications Intraoperative Small Parts Vascular Pediatrics Probe Band Width 4 0 12 0 MHz Number of Element 192 FOV Max 39 mm Physical Foot Print 44 x 10 mm B mode Imaging Frequency 6 0 8 0 10 0 MHz Harmonic Frequency 8 0 10 0 12 0 MHz Doppler Frequency 5 0 6
19. 6 steps e Scanning Size FOV or Angle probe dependent see probe specifications e Gray Scale Map 23 types e Gain 0 98 dB 2 dB step e Dynamic Range 30 120 dB 3 dB step e Depth 1 30 cm 1 cm step depend on probe e Rejection 6 steps e Frequency Up to 5 steps depend on probe Dual Beam On Off pre settable e Auto Line Density On Off pre settable Diff On Off e Steered Linear 15 LOGIQ 7 Product Data Sheet Color Flow Mode e Base Line 0 100 10 step e Invert On Off e CF PDI Focus Depth default pre settable for 0 100 of ROI in depth 10 step e CF PDI Flash Suppression 2 steps e CF PDI Acoustic Output 0 100 10 step e CF PDI Angle Steer 0 20 e Packet Size 5 16 dependent on probe application e Line Density 5 steps e Line Density Zoom 5 steps e Frame Average 7 steps e PRF 280 Hz 19600 Hz Spatial Filter 6 steps e Gain 0 40 dB 0 5 dB step e Wall Filter 7 steps depend on probe application e Scanning Size FOV or Angle probe dependent e CF PDI Vertical Size mm of ROI default pre settable e CF PDI Center Depth mm of ROI default pre settable e CF PDI Frequency Up to 2 steps depend on probe e Color Map 20 types depend on application e Transparent 5 steps e Color Threshold 0 100 5 step e Arbitration Threshold 15 steps pre settable e Auto Line Density On Off pre settable e PW CF Ratio 1 2
20. LOGIQ 7 Product Data Ver 4 Rev 0 October 13 2004 Product Description The LOGIQ 7 is a high performance multipurpose imaging system designed for abdominal vascular obstetrics gynecology cardiology neonatal urology transcranial and small parts applications System Architecture TruScan Architecture GE s exclusive software intensive platform provides unsurpassed computational power image manipulation capability workflow flexibility and product upgrade ability The LOGIQ 7 excels in the following areas Image Quality superiority is created through the use of CrossBeam SRI Coded Techniques and world class transducers Raw Data is GE s exclusive technology that allows a virtual rescan on archived images by applying the same scan controls available during the original exam Productivity features to make the LOGIQ 7 the most productive U S system including the new Automatic Optimization Ergonomics provide the most ergonomic U S system available including VoiceScan General Specification Dimensions and Weight Height Minimum 1441 mm 57 in Maximum 1606 mm 63 in e Width 599 mm 24 in Depth 999 mm 39 in e Weight approx 226 kg 498 Ib Electrical Power e Voltage 100 120 VAC or 220 240 VAC e Frequency 50 60 Hz e Maximum Power Consumption 1 2K VA with on board peripherals 0 7K VA without peripherals LOGIQ 7 Product Data Sheet TruScan Imaging Technology e Maximum
21. Probe Applications Abdomen OB Gyn Urology Probe Band Width 3 0 8 0 MHz Number of Element 128 Convex Radius 40 mmR FOV Max 73 Physical Foot Print 54 x 13 mm B mode Imaging Frequency 4 0 5 0 6 0 MHz Doppler Frequency 4 0 5 0 MHz Biopsy Guide Available Multi Angle Reusable Page 7 e M7C Matrix Array Wide Band Convex Number of Element 64 Doppler Frequency 5 0 6 7 MHz Probe FOV Max 90 Steered Angle 0 5 10 15 20 Applications Abdomen OB Gyn Physical Foot Print 21 x 15 mm Biopsy Guide Available Multi Angle Pediatrics B mode Imaging Frequency 2 0 2 5 Reusable Probe Band Width 3 0 8 0 MHz 3 0 MHz e M12L Matrix Array Wide Band Linear Number of Element 960 Harmonic Frequency 2 8 3 0 3 2 3 6 Probe Convex Radius 40 mmR MHz Applications Small Parts Vascular FOV Max 63 Doppler Frequency 1 7 2 0 MHz Neonatal Pediatrics Physical Foot Print 55 x 18 mm CW Doppler Frequency 2 0 MHz Probe Band Width 5 0 14 0 MHz B mode Imaging Frequency 6 0 7 0 Biopsy Guide Available Multi Angle Number of Element 960 8 0 MHz Reusable FOV Max 39 mm Harmonic Frequncy 6 0 7 0 MHz e 7S Wide Band Phased Array Sector Physical Foot Print 45 x 10 mm Doppler Frequency 4 0 5 0 MHz Probe B mode Imaging Frequency 7 0 10 0 Biopsy Guide Available Multi Angle Applications Cardiac Per
22. RS complex to end of envelope Q to PV close e Right Ventricle Page 10 Right Ventricle Internal Diameter RVIDd RVIDs Right Ventricle Wall Thickness RVAWd RVAWs Right Ventricle Outflow Tract Diameter RVOT Diam Right Ventricle Ejection Time RVET Right Ventricle Pre Ejection Period RVPEP Velocity Circumferential Fiber Shortening Vcf e System Interventricular Septum Thickness IVSd IVSs Pericard Effusion PE d Interventricular Septum IVS Fractional Shortening IVSd IVSs e Tricuspid Valve QRS complex to end of envelope Q to TV close Doppler Mode Measurements e Aortic Valve Aortic Insufficiency Mean Pressure Gradient AR Trace Aortic Insufficiency Peak Pressure Gradient AR Vmax Aortic Insufficiency End Diastole Pressure Gradient AR Trace Aortic Insufficiency Mean Velocity AR Trace Aortic Insufficiency Mean Square Root Velocity AR Trace Aortic Insufficiency Velocity Time Integral AR Trace Aortic Valve Mean Velocity AV Trace Aortic Valve Mean Square Root Velocity AV Trace Aortic Valve Velocity Time Integral AV Trace Aortic Valve Mean Pressure Gradient AV Trace Aortic Valve Peak Pressure Gradient AR Vmax Aortic Insufficiency Peak Velocity AR Vmax Aortic Insufficiency End Diastolic Velocity AR Trace Aortic Valve Peak Velocity AV Vmax Aortic Valve Peak Velocity at Point E AV Vmax Aorta Proxim
23. al Coarctation Coarc Pre Duct Aorta Distal Coarctation Coarc Post Duct Aortic Valve Insufficiency Pressure Half Time AR PHT Aortic Valve Flow Acceleration AV Trace Aortic Valve Pressure Half Time AV LOGIQ 7 Product Data Sheet Trace Aortic Valve Acceleration Time AV Acc Ti me Aortic Valve Deceleration TIme AV Trace Aortic Valve Ejection Time AVET Aortic Valve Acceleration to Ejection Time Ratio AV Acc Time AVET Aortic Valve Area according to PHT e Left Ventricle Left Ventricle Outflow Tract Peak Pressure Gradient VLOT Vmax Left Ventricle Outflow Tract Peak Velocity LVOT Vmax Left Ventricle Outflow Tract Mean Pressure Gradient LVOT Trace Left Ventricle Outflow Tract Mean Velocity LVOT Trace Left Ventricle Outflow Tract Mean Square Root Velocity LVOT Trace Left Ventricle Outflow Tract Velocity Time Integral LVOT Trace Left Ventricle Ejection Time LVET Cardiac Output by Aortic Flow AVA Pl ani met ry AV Trace Stroke Volume Index by Aortic Flow AVA Planimetry AV Trace e Mitral Valve Mitral Valve Regurgitant Flow Acceleration MR Trace Mitral Valve Regurgitant Mean Velocity MR Trace Mitral Regurgitant Mean Square Root Velocity MR Trace Mitral Regurgitant Mean Pressure Gradient MR Trace Mitral Regurgitant Velocity Time Integral MR Trace Mitral Valve Mean Velocity MR Trace Mitral Valve Mean Square Root Velocity MR Trace Mitral Valve Ve
24. al R Trigger e Pre settable ECG R Delay Time e Pre settable ECG Position e Adjustable ECG Gain Control e Pre settable PCG Position e Adjustable PCG Gain Control Pre settable AUX Position e Adjustable AUX Gain Control e Automatic Heart Rate Display Measurements Calculations General B Mode Depth amp Distance e Circumference Ellipse Trace e Area Ellipse Trace e Volume Ellipsoid e Stenosis Area or Diameter e Angle between two lines General M Mode e M Depth Distance e Time Slope e Heart Rate General Doppler Measurements Calculations e Velocity e Time e A B Ratio Velocities Frequency Ratio e PS Peak Systole ED End Diastole e PS ED PS ED Ratio ED PS ED PS Ratio e AT Acceleration Time e ACCEL Acceleration e TAMAX Time Averaged Maximum Velocity e Volume Flow TAMEAN and Vessel Area e Heart Rate e PI Pulsatility Index e RI Resistivity Index Real time Doppler Auto Measurements Calculations e PS Peak Systole ED End Diastole e MD Minimum Diastole e PI Pulsatility Index e RI Resistivity Index e AT Acceleration Time e ACC Acceleration PS ED PS ED Ratio ED PS ED PS Ratio e HR Heart Rate e TAMAX Time Averaged Maximum Velocity e PVAL Peak Velocity Value e Volume Flow TAMEAN and Vessel Area Page 6 OB Measurements Calculations e Gestational Age by GS Gestational Sac CRL Crown Rump Length
25. ange and Baseline Color Threshold Marker Color Gain PDI Color Scale Inversion Color Doppler Frequency e TGC Curve e Acoustic Frame Rate e Cine Frame Number LOGIQ 7 Product Data Sheet e VCR Counter e VCR Status a VCR Playback Counter e Body Pattern Application Name e Measurement Results e Operator Message e Displayed Acoustic Output TIS Thermal Index Soft Tissue TIC Thermal Index Cranial Bone TIB Thermal Index Bone MI Mechanical Index e of Power output e Biopsy Guide Line and or Zone e Heart Rate General System Parameters System Setup e Pre programmable Categories e User Programmable Preset Capability e Factory Default Preset Data e Languages English French German Spanish Italian Portuguese Russian Greek Swedish Danish Dutch Finnish Norwegian e OB Report Format 5 Types Tokyo Univ Osaka Univ USA Europe and ASUM e EFBW 10 types Japan USA and Europe Tokyo Univ Osaka Univ Tokyo Shinozuka JSUM German Shephard Merz Hadlock Shephard Williams Brenner 348 Pre defined Annotations and User Programmable Libraries Annotations Body Patterns 134 human types plus 14 animal types e Customized Comment Home Position Complete User Manual available on board through Help F1 User Manual and Service Manual are included on CD with each system A printed Manual is available upon request CINE Memory Image Memory e CINE Memory 128MB standard
26. animetry Trans AVA Left Atrium Left Atrium Diameter LA Diam LA Length LA Major LA W idth LA Minor Left Atrium Diameter to AoRoot Diameter Ratio LA Ao Ratio Left Atrium Area LAA d LAA s Left Atrium Volume Single Plane Method of Disk LAEDV A2C LAESV A2C LAEDV A4C LAESV A4C e Left Ventricle Left Ventricle Mass LVPWd LVPWs Left Ventricle Volume Teichholz Cubic LVIDd LVI Ds Left Ventricle Internal Diameter LVIDd LVI Ds Left Ventricle Length LVLd LVLs Left Ventricle Outflow Tract Diameter LVOT Diam Left Ventricle Posterior Wall Thickness LVPWd LVPWs Left Ventricle Length LV Major Left Ventricle Width LV Minor Left Ventricle Outflow Tract Area LVOT Left Ventricle Area Two Chamber Four Chamber Short Axis LVA d LVA s Left Ventricle Endocardial Area Width LVA d LVA s Left Ventricle Epicardial Area Length LVAepi d LVAepi s Left Ventricle Mass Index LVPWd LVPWs Ejection Fraction Teichholz Cube LVIDd LVIDs Left Ventricle Posterior Wall Fractional LOGIQ 7 Product Data Sheet Shortening LVPWd LVPWs Left Ventricle Stroke Index Teichholz Cube LVIDd LVIDs and Body Surface Area Left Ventricle Fractional Shortening LVIDd LVIDs Left Ventricle Stroke Volume Teichholz Cubic LVIDd LVIDs Left Ventricle Stroke Index Single Plane Two Chamber Method of Disk LVI Dd
27. d Diastolic Velocity PV Trace Pulmonary Artery Diastolic Pressure PV Trace Pulmonic Insufficiency Mean Pressure Gradient PR Trace Pulmonic Valve Mean Pressure Gradient PV Trace Pulmonic Insufficiency Mean Velocity PR Trace Pulmonic Insufficiency Mean Square Root Velocity PR Trace Pulmonic Insufficiency Velocity Time Integral PR Trace Pulmonic Valve Mean Velocity PV Trace Pulmonic Valve Mean Square Root Velocity PV Trace Pulmonic Valve Velocity Time Integral PV Trace Pulmonic Insufficiency Pressure Half Time PR PHT Pulmonic Valve Flow Acceleration PV Acc Time Page 11 Pulmonic Valve Acceleration Time PV Acc Time Pulmonic Valve Ejection Time PVET Pulmonic Valve Pre Ejection Period PVPEP QRS complex to end of envelope Q to PV close Pulmonic Valve Acceleration to Ejection TIme Ratio PV Acc Time PVET Pulmonic Valve Pre Ejection to Ejection Time Ratio PVPEP PVET e Right Ventricle Right Ventricle Outflow Tract Peak Pressure Gradient RVOT Vmax Right Ventricle Systolic Pressure RVOT Vmax Right Ventricle Outflow Tract Peak Velocity RVOT Vmax Right Ventricle Diastolic Pressure RVOT Trace Right Ventricle Outflow Tract Velocity Time Integral RVOTTrace Right Ventricle Ejection Time RV Trace Stroke Volume by Pulmonic Flow RVOT Planimetry RVOTTrace Right Ventricle Stroke Volume Index by Pulmonic Flow RVOT P
28. diatrics 12 0 14 0 MHz Reusable Abdomen Harmonic Frequency 10 0 12 0 14 0 E8C Wide Band Microconvex Probe Probe Band Width 3 1 8 0 MHz MHz Applications OB Gyn Urology Number of Element 96 Doppler Frequency 5 0 6 7 MHz Endocavity FOV Max 90 Steered Angle 0 5 10 15 20 Probe Band Width 4 0 11 0 MHz Physical Foot Print 18 x 12 mm Biopsy Guide Available Multi Angle Number of Element 128 B mode Imaging Frequency 4 0 6 5 Reusable Convex Radius 11 mmR 8 0 MHz e i12L Intraoperative Wide Band Linear FOV Max 133 Harmonic Frequency 7 0 8 0 MHz Probe Physical Foot Print 23 x 10 mm Doppler Frequency 4 0 5 0 MHz Applications Intraoperative Small B mode Imaging Frequency 6 0 8 0 CW Doppler Frequency 4 0 MHz Parts Vascular Pediatrics 10 0 MHz 5 Biopsy Guide Available None Probe Band Width 5 0 12 0 MHz Harmonic Frequency 8 0 10 0 MHz e 10S Wide Band Phased Array Sector Number of Element 96 Doppler Frequency 4 0 5 0 MHz Probe FOV Max 25 mm Biopsy Guide Available Single Angle Applications Neonatal Small Parts Physical Foot Print 29 x 10 mm Disposable and Reusable Abdomen Pediatrics B mode Imaging Frequency 6 0 8 0 e 8C Wide Band Microconvex Probe Probe Band Width 4 0 11 0 MHz 10 0 MHz Applications Neonatal Pediatrics Number of Element 96 Harmonic Frequency 10 0 12 0MHz Probe Band Width 4 0
29. e Layout in Measurement Annotation and Body Pattern Menus Monitor 17 inch Non Interlace High Resolution and Flat Display e SVGA Format Display size 800x600 Recording area 640x480 e Tilt Rotate Adjustable Tilt angle up down 10 Rotate angle right left 90 e Height Adjustable with keyboard 1255 1420 mm 49 56 in at center of monitor e Digital Brightness Contrast Adjustment Integrated Hi Fi Speakers e Integrated Microphone Page 1 System Overview Applications Abdominal e Obstetrical e Gynecological e Cardiac e Musculoskeletal e Vascular e Urological e Small Parts and Superficial e Breast e Pediatric and Neonatal e Orthopedic Transcranial Intraoperative Scanning Methods Electronic Sector e Electronic Convex Electronic Linear Transducer Types e Sector Phased Array e Convex Array e Microconvex Array e Linear Array e Matrix Arrays e Single CW Pencil Probes e Multi plane Sector Phased Array e Bi plane Microconvex Arrays Operating Modes e B Mode Coded Harmonic Imaging e M Mode Color Flow Mode CFM e Power Doppler Imaging PDI with Directional Map e PW Doppler with High PRF e M Color Flow Mode e Anatomical M Mode e Anatomical M Color Mode B Flow Mode option e B Flow Color Mode option e Coded Contrast Imaging option e CW Doppler Mode option e PFD Mode option e Tissue Velocity Imaging TVI Mode option e Curved
30. equipment ISO 10993 Biological evaluation of medical devices NEMA UD3 Acoustic output display MI TIS TIB TIC GE LOGIQ 7 is designed for compatibility with commercially available ultrasound contrast agents Because the availability of these agents is subject to government regulation and approval product features intended for use with these agents may not be commercially marketed nor made available before the contrast agent is cleared for use Contrast related product features are enabled only on systems for delivery to an authorized country or region of use GE Healthcare makes no claims concerning the safety or effectiveness of contrast agents Not all features or specifications described in this document may available in all probes and or modes General Electric Company reserves the right to make changes in specifications and features shown herein or discontinue the product at any time without notice or obligation Contact GE Representative for the most current information Page 9 Supplement Cardiac Measurements Calculations B Mode Measurements Aorta Aortic Root Diameter Ao Root Diam Aortic Arch Diameter Ao Arch Diam Ascending Aortic Diameter Ao Asc Descending Aortic Diameter Ao Desc Diam Aorta Annulus Diameter Ao Annulus Diam Aorta Isthmus Ao Isthmus Aorta Ao st junct e Aortic Valve Aortic Valve Cusp Separation AV Cusp Aortic Valve Area Planimetry AVA Pl
31. ke Volume by Aortic Flow AVA Planimetry AV Trace e Mitral Valve Stroke Volume by Mitral Flow MVA Page 12 Planimetry MV Trace Cardiac Output by Mitral Flow MVA Planimetry MV Trace HR e Pulmonic Valve Stroke Volume by Pulmonic Flow PV Planimetry PV Trace Cardiac Output by Pulmonic Flow PV Planimetry PV Trace HR e Tricuspid Valve Cardiac Output by Tricuspid Flow TV Planimetry TV Trace HR Cardiac Worksheet e Parameter lists the mode the measurement folder and the specific measurement e Measured Value Up to six measurement values for each item Average maximum minimum or last Generic Study in Cardiology Stroke Volume SV e Flow Volume FV e Cardiac Output CO e Flow Volume Output FVO LOGIQ 7 Product Data Sheet Page 13
32. lanimetry RVOT Trace e System Pulmonary Artery Peak Velocity PV Vmax Pulmonary Vein Velocity Peak A reverse P Vein A Pulmonary Vein Peak Velocity P Vein D P Vein S Systemic Vein Peak Velocity PDA Diastolic PDA Systolic Ventricular Septal Defect Peak Velocity VSD Vmax Atrial Septal Defect ASD Diastolic ASD Systolic Pulmonary Artery Velocity Time Integral PV Trace Systemic Vein Velocity Time Integral PDA Trace Pulmonary Vein A Wave Duration P Vein A Dur IsoVolumetric Relaxation Time IVRT IsoVolumetric Contraction Time IVCT Pulmonary Vein S D Ratio P Vein D P Vein S Ventricular Septal Defect Peak Pressure Gradient VSD Vmax Pulmonic to Systemic Flow Ratio Qp Qs e Tricuspid Valve Tricuspid Regurgitant Peak Pressure Gradient TR Vmax Tricuspid Valve Peak Pressure LOGIQ 7 Product Data Sheet Gradient TV Vmax Tricuspid Regurgitant Peak Velocity TR Vmax Tricuspid Valve Peak Velocity TV Vmax Tricuspid Valve Velocity Peak A TV A Velocity Tricuspid Valve Velocity Peak E TV E Velocity Tricuspid Regurgitant Mean Pressure Gradient TR Trace Tricuspid Valve Mean Pressure Gradient TV Trace Tricuspid Regurgitant Mean Velocity TR Trace Tricuspid Regurgitant Mean Square Root Velocity TR Trace Tricuspid Regurgitant Velocity Time Integral TR Trace Tricuspid Valve Mean Velocity TV Trace Tricuspid Valve
33. locity Time Integral MR Trace Mitral Valve Mean Pressure Gradient MR Trace Mitral Regurgitant Peak Pressure Gradient MR Vmax Mitral Valve Peak Pressure Gradient MR Vmax Mitral Regurgitant Peak Velocity MR Vmax Mitral Valve Peak Velocity MR Vmax Mitral Valve Velocity Peak A MV A Velocity Mitral Valve Velocity Peak E MV E Velocity Mitral Valve Area according to PHT MV PHT Mitral Valve Flow Deceleration MV Trace Mitral Valve Pressure Half Time PV PHT Mitral Valve Flow Acceleration MV Trace Mitral Valve E Peak to A Peak Ratio A C and D E MV E ARatio Mitral Valve Acceleration Time MV Acc Time Mitral Valve Deceleration Time MV Dec Time Mitral Valve Ejection Time MV Trace Mitral Valve A Wave Duration MV A Dur Mitral Valve Time to Peak MV Trace Mitral Valve Acceleration Time Deceleration Time Ratio MVAcc Dec Time Stroke Volume Index by Mitral Flow MVA Planimetry MVTrace Mitral Valve Area from Continuity Equation MVAPlanimetry LVOT Vmax MV Vmax e Pulmonic Valve Pulmonic Insufficiency Peak Pressure Gradient PR Vmax Pulmonic Insufficiency End Diastolic Pressure Gradient PRTrace Pulmonic Valve Peak Pressure Gradient PV Vmax Pulmonic End Diastolic Pressure Gradient PR Trace Pulmonic Insufficiency Peak Velocity PR Vmax Pulmonic Insufficiency End Diastolic Velocity Prend Vmax Pulmonic Valve Peak Velocity PV Vmax Pulmonic En
34. ore of SR iLing capability VoiceScan optional e Provides for Voice control of scanner e Over 150 voice commands e Voice Profile per user e Separate training file per user e Training file moveable between systems e Wired microphone attached as USB device Page 3 e Wireless microphone 518 550MHz adjustable range 30mW output power Scanning Parameters e Digital Beamformer e 7168 Maximum Virtual Channels Displayed Imaging Depth 0 30 cm e Minimum Depth of Field 0 1cm probe dependent e Maximum Depth of Field 0 30 cm probe dependent Transmission Focus 1 8 Focus Points Selectable probe and application dependent Focal Zone Position up to 19 steps Transmission Apodization Dual Beamforming in B Mode Quad Beamforming in CFM e Continuous Dynamic Receive Focus Aperture e Multi Frequency Wideband Technology e 256 Shades of Gray 16 777 216 Hues of Color e 172 dB Dynamic Range e Adjustable Field of View FOV e Image Reverse Right Left e Image Rotation 2 steps Rotation 0 180 B Mode e B M Acoustic Output 0 100 2 step e Image Reverse On Off e B Color 8 types Thermal Index TIC TIS TIB e Softener 4 steps e Focus Number 8 steps e Focus Width 3 types e Range Focus On Off e Compression 0 5 1 5 0 1 step e Line Density 4 steps e Line Density Zoom 4 steps e Suppression 6 steps e Frame Average 8 steps e Edge Enhance
35. ry Reports Vascular Measurements Calculations e SYS DCCA Systolic Distal Common Carotid Artery e DIAS DCCA Diastolic Distal Common Carotid Artery e SYS MCCA Systolic Mid Common Carotid Artery DIAS MCCA Diastolic Mid Common Carotid Artery e SYS PCCA Systolic Proximal Common Carotid Artery e DIAS PCCA Diastolic Proximal Common Carotid Artery e SYS DICA Systolic Distal Internal Carotid Artery e DIAS DICA Systolic Distal Internal Carotid Artery e SYS MICA Systolic Mid Internal Carotid Artery e DIAS MICA Diastolic Mid Internal Carotid Artery e SYS PICA Systolic Proximal Internal Carotid Artery e DIAS PICA Diastolic Proximal Internal Carotid Artery e SYS DECA Systolic Distal External Carotid Artery e DIAS DECA Diastolic Distal External Carotid Artery e SYS PECA Systolic Proximal External Carotid Artery e DIAS PECA Diastolic Proximal External Carotid Artery e VERT Systolic Vertebral Velocity e SUBCLAV Systolic Subclavian Velocity e Summary Reports Cardiac Measurements Calculations e Cardiac calculation package including extensive measurements and display of multiple repeated measurements e Parameter annotation follow ASE standard See Supplement for details Report Writer Option e On board reporting package automates report writing e Formats various exam results into a report suitable for printing to a windows printer or reviewing on a standard PC e Exam resul
36. tput Doppler Frequency Velocity Scale PRF PW CF Ratio Wall Filter Time Resolution Sample Volume Gate for PW Mode Length Depth e Color Flow Mode CFM Gain CFM Velocity Scale PRF or PFD Scale PRF Acoustic Output CFM Frequency Wall Filter Packet Size CFM Spatial Filter CFM Line Density LOGIQ 7 Product Data Sheet CFM Regression Filter Accumulation Post Processing w TruAccess Raw Data e SRI Selectable level of Speckle Reduction Imaging e Max Read Zoom to 8x e B M Mode ATO Auto Tissue Optimization Image Reverse Image Rotation Gray Map Colorized B and M Post Gain Compression Rejection Frame Averaging B Softener Suppression Sweep Speed for M Mode Anatomical M Mode e PW CW Mode ASO Auto Spectral Optimization Base Line Shift Gray Map Post Gain Compression Rejection Spectral Averaging Colorized D Display Format Sweep Speed e Color Flow Mode ACO Auto Color Optimization Base Line Shift Color Map Post Gain Frame Averaging CFM Display Threshold Angle Correct PW mode Quick Angle Correct PW mode Auto Angle Correct PW mode Spectral Invert for Color and Doppler 3D reconstruction from a stored CINE loop e Anatomical M Mode e Curved Anatomical M Mode e Accumulation e Cine Capture Physiological Input Panel Option e Physiological Input ECG 1 channel PCG 1 channel AUX 2 channel Du
37. ts include patient info exam info measurements calculations images comments and diagnosis Standard templates provided e Customizable templates Probes e 3 5C Wide Band Convex Probe Applications Abdomen OB Gyn Urology Vascular Probe Band Width 2 0 5 5 MHz Number of Element 128 Convex Radius 40 mmR FOV Max 68 Physical Foot Print 53 x 18 mm B mode Imaging Frequency 2 0 3 0 4 0 5 0 5 5 MHz Harmonic Frequency 4 0 4 5 5 0 5 2 5 5 MHz Doppler Frequency 2 0 3 3 MHz Biopsy Guide Available Single Angle Reusable e 3 5CS Wide Band Convex Probe Applications Abdomen OB Gyn Urology Vascular Probe Band Width 2 0 5 5 MHz Number of Element 128 Convex Radius 40 mmR FOV Max 68 Physical Foot Print 53 x 13 mm B mode Imaging Frequency 2 0 3 0 4 0 5 0 5 5 MHz Harmonic Frequency 4 0 4 5 5 0 5 2 5 5 MHz Doppler Frequency 2 0 3 3 MHz Biopsy Guide Available Single Angle Reusable 3C Wide Band Convex Probe Applications Abdomen OB Gyn Urology Probe Band Width 2 0 5 0 MHz Number of Element 128 Convex Radius 55 mmR FOV Max 58 Physical Foot Print 60 x 14mm B mode Imaging Frequency 2 0 3 0 4 0 5 0 MHz Harmonic Frequency 4 0 5 0 MHz Doppler Frequency 2 5 3 3 MHz Biopsy Guide Available Multi Angle Reusable 5C Convex
Download Pdf Manuals
Related Search
Related Contents
Automatic No-bark Collar Installation Guide - University of Kent MacroVue UV-20 Compact – Guía de Rescate en Avalancha EndoStim User Manual manuale di manutenzione Sun Cluster Handbuch Softwareinstallation für Solaris OS Guida dell`utente della fotocamera - Migros Copyright © All rights reserved.
Failed to retrieve file