1. For an arm of 239mm eff like the Artemis TA 1 arm a correct overhang adjustment after Baerwald results in average tracing error related tracking distortion of barely more than 0 4 Next the azimuth should be adjusted so that crosstalk is the same for both channels With a perfect equal output on both channels cartridge this can be done by using a mono record played back via an X adaptor or through your preamp switched to mono Reverse the headshell clips on one channel only switch red and green i e and adjust for the weakest signal coming from your speakers It s better to adjust for equal crosstalk using a proper test record or better yet use Dr Feickert s Adjust Plus software Azimuth on the TA 1 arm is altered by loosening the armwand set screw E 1 enough to allow turning the armwand F clock or counter clockwise until the headshell plate appears to be parallel with the record surface as a starting point If the resulting image stability leaves something to be desired turn the armwand in small increments clock or counter clockwise This will allow you to compensate for minor misalignments of the stylus cantilever assembly Once you ve hit it on the nail a centrally recorded female voice should be precisely located in space with no difference in the decay characteristics between channels Starting with the armwand parallel to the record surface VTA adjustment should be carried out in small steps until the
2. a wooden plinth a suitable brass or stainless wood screw If you need to secure your arm i e when carrying the turntable around please use a rubber band The arm doesn t feature a locking mechanism as these always leave marks with time AND resonate There is no rsk omitting this feature as the arm s design doesn t allow for the cartridge to be dropped onto the plinth or mounting board Page 1 The following schematics will help you to identify the tonearm parts including the set screws necessary to properly align your arm and cartridge C 1 D D 2 D 1 rrOMmmMmmmM ae eas ta T Mounting collar Mounting screw M6 cylinder head Mounting collar set screw Arm shaft Lift holder bar Antiskating adjustment screw Counterweight Counter weight set screw Armwand receptacle Armwand set screw Armwand Headshell section Headshell set screw Headshell cartridge mounting plate Arm lift Lift bank Skating compensation screw Arm seen from left Page 2 Arm seen from right Armwand counterweight assembly seen from above 2 The tonearm wiring This tonearm comes standard with a cable that was chosen for it s sonic and mechanical properties The signal is carried in a single run from the cartridge clips to the headamp or phonostage omitting additional soldered connections The wiring exist the tonearm shaft through a disc that acts as a strain relief Do not loosen either of the two set screws
3. best separation between individual instrument in space the least amount of grain audible and the best integration of fundamentals and upper harmonics is achieved see above There is no perfect position varying record thickness and a different cutting angle used for most records made before 1965 necessitate a new setting for every other record if you want to get the absolute best out of each record Stylus shapes are also more or less susceptible to changes in the VTA generally speaking the sharper the stylus smaller radius longer contact zone the more sensitive to changes The more time you spend on adjusting the VTA the less you ll get to actually enjoy your records The tracking force determines the tracking ability and also the position of the coils in the magnetic generator Follow the manufacturer s recommendation and try increasing or lowering the tracking force by increments of 0 05gr Low frequency tracking ability shouldn t be much lower than 7Omy Soundwise more relevant is the high frequency tracking ability The appropriate tracks on the Shure TT115 test record are helpful to get closer to the optimal tracking force Again being able to sail through every torture test doesn t mean your setting is perfect Too high a tracking force will help cope with demanding test records but much more important is the proper load on the cantilever damper assembly to ensure maximum dynamics The counter
4. the bearing Using the supplied alignment gauge will result in achieving a proper outer zero point 120 9mm once you have managed to get the inner zero point 66 04mm right Next check the tangency of the cantilever at the zero points as seen from above front hold the armlift so that the stylus is not quite touching the alignment gauge and if necessary raise it Page 4 again and turn the headshell mounting plate without sliding it forward or backward again making sure the cantilever not the cartridge body is tangential to the record Finally tighten screw F 2 again If the cantilever of your cartridge is aligned perfectly parallel with the sides of the cartridge body rarely the case you ll find the front of the headshell plate to be perfectly parallel with the front of the headshell F 1 The cartridge mounting plate G has bevelled polished edges to make it easier to see slight deviations from parallel alignment relative to the front of the headshell F 1 A non parallel cartridge mounting plate alignment is therefore required if the cantilever isn t well aligned relative to the cart body Now set the tracking force to the value recommended by the cartridge manufacturer by sliding the counter weight D again forward or backward on the end stub of the armwand It is recommendable to use a high quality digital gauge but even the venerable Shure see saw gauge will yield dependable if only low res mea
5. Artemis Labs Model TA 1 Instruction Manual Dear Customer Congratulations You have purchased a unique tonearm that will transcribe the most accurate detail and provide the most musically enjoyable reproduction from your vinyl records The tonearm features ceramic hybrid bearings of the highest quality reducing bearing friction to unprecedented low levels lt 2mg insuring years of trouble free performance To take full advantage of this inherently superior design please take the time to study and familiarise yourself with this manual hope you will enjoy mounting and adjusting the tonearm and rediscovering your record collection 1 Mounting the tonearm Mounting the arm requires drilling a 23 mm 0 90 inch to 25mm 0 98 inch max hole Rega mounting in your plinth or armboard plus a single tapped hole for the mounting screw A 1 non magnetic M6 supplied with the arm The pivot to spindle distance for your arm measures 222mm Please study the mounting schematic for the correct placement of the teardrop shaped mounting collar A and its mounting screw Deviations from the suggested orientation are permissible as long as the mounting collar A doesn t interfere with the arm s counterweight while maintaining the p s distance of 222mm Once you have found a suitable position and drilled tapped the M6 hole screw the mounting collar A to the base or plinth of your tonearm using the supplied M6 screw or if your turntable features
6. dge mounting plate G using the supplied M2 5 non magnetic stainless steel screws while the plate is off the tonearm First separate the mounting plate G from the armwand by unscrewing the headshell set screw F 2 Usually it is sufficient to tighten the M2 5 screws well but not excessively so Over tightened screws can result in internal tensions in the cartridge body negatively affecting the sound or even damaging the internal structure Don t forget the next step after REALLY tight is totally loose Connecting the mounting plate G with the armwand requires re tightening the headshell set screw F 2 The applied torque should be varied from just finger tight to reasonably tight excessive application of force is not recommended see paragraph 5 4 3 Tracking force overhang and tangency zenith Take the counter weight D 2 and slide it onto the back section of the armwand F Leave your stylus cover if your cartridge features such a device on and set the tracking force to approx 1 5 gr Tighten the counterweight set screw E 1 just so that you can still slide and turn the counterweight without applying too much pressure Using a proper template i e Dennesen Wallytractor AccuTrak Dr Feickert or mine which comes with the arm overhang is now adjusted by first loosening the screw F 2 just so it barely grips then sliding the cartridge mounting plate G towards or away from
7. ntact Artemis Labs In any case a slight under compensation is always to be preferred over even the slightest overcompensation The use of most test records and their torture tracks gt 80u will yield too high a compensation because there are no continuous signals of this magnitude on any record As a start just put the diamond on the space between the leadout grooves or a blank record i e Cardas sweeper record and adjust antiskating until the arm cartridge combo wanders slowly towards the center of the record From then on use your ears 5 The finetuning Everyone who has to mount cartridges frequently understands the importance of precisely adjusting an arm cartridge combination to release it s full potential Overhang azimuth VTA tracking force and if featured variable damping of the arm movement are all important parameters Page 5 The overhang adjustment was described already nevertheless let me add that a single perfect overhang setting does not exist Should you own a lot of records that are cut close to the inner groove you might consider using 68mm instead of 66mm as your inner zero point many crescendo finales of symphonic works could be tracked with reduced distortion this way On the other hand exist a lot of Pop records with no modulation but leadout groove already where the inner zero point is located One doesn t even benefit from this second distortion minimum
8. on the lower end of the shaft or the disc at its very end as this will disable the strain relief Page 3 3 Electrical connections grounding The conductors connectors are colour coded according to the international standard Red right channel hot green right channel ground white left channel hot blue left channel ground RCA plugs red right channel black left channel The standard wiring is shielded from the arm to the RCA plugs The ground wire is to be connected to the following amplification stage s ground If you use a star grounding pattern connect the ground wire to your central ground 4 Adjusting your tonearm cartridge 4 1 Alignment of the arm relative to the turntable After the arm collar A has been screwed down to the arm board or plinth excessive force is not required first insert the wiring then the shaft B into the collar A as far as it is required to end up with the armwand F roughly parallel to the platter Then turn the shaft B so the tonearm in its resting position armwand at rest close to the right end of the lift bank will be parallel to the right side of the turntable plinth or so it s visually agreeable if your turntable has an irregular or circular shape Any position is fine as long as the armwand will be within range of the liftbank throughout the usable record radius 4 2 Mounting your cartridge The cartridge can be mounted to the cartri
9. surements This is because the Artemis arm is a neutral balance design so changes in VTA record thickness or measuring height of your VTF gauge will not change VTF setting 4 4 VTA SRA Vertical Tracking Angle Stylus Rake Angle adjustment As a Starting point you should raise or lower the tonearm until the armwand F appears to be parallel to the record surface with the needle in the groove Just unscrew the VTA set screw A 2 then slide the shaft B up or down until this has been achieved The fine adjustment has to be carried out using your ears Raise or lower the arm by small increments until you have reached a position that combines precise placement of images with an effortless delivery of dynamic contrasts Sibiliants should come from the same position in space as the singer s head not from a point in front of it 4 5 Antiskating To compensate for the skating force turn the antiskating adjustment screw C 1 clockwise to increase force and counter clockwise to reduce it Skating compensation will always be a compromise because the required compensation force for a given VTF depends upon the stylus geometry the quality of the polished contact zone the vinyl formulation the modulation level arm bearing friction etc The skating force compensation of the Artemis Labs TA 1 is sufficient for a tracking force up to 2 3 gr Upon request higher tracking forces can be compensated for by exchanging the antiskating screw please co
10. ter 23mm Distance between mounting surface and platter level 25 60mm best 30 35mm Ceramic hybrid bearings with unprecedented low friction lt 2mg vertically lt 3 5mg horizontally Internal magnetic damping for the horizontal movement Frictionless resonance free magnetic antiskating Cryogenics treated low loss high purity copper wiring single run from cartridge clips to RCAs 1m from arm to RCAs Armwand made out of Kingwood Available in black and silver Contact Information info artemislabs com Page 7
11. weight D features a bottom element D 2 that can be screwed to its upper counterpart more or less tightly a polymer element gets compressed up to a point where finally hard contact is made In addition the inset screwed in from the bottom can be exchanged for a lighter or heavier cylinder available through Artemis Labs allowing for an increase or decrease of total counterweight mass without altering the overall mass distribution of the arm This way even ultra light or very heavy cartridges can be used as long as their weight compliance yields a fundamental arm cartridge resonance frequency of 8 12Hz Page 6 The amount of tightening of any of the arm s screws has an influence on the energy transmission and dissipation and should be experimented with Generally speaking only screws A 1 and A 2 should be tightened well Screws D 1 tightest E 1 less tight and F 2 seldom more than finger tight require some experimentation Should you have any questions regarding mounting adjusting or technical details of this tonearm feel free to contact us via phone or email Equally welcome is any sort of criticism or suggestions for improvements Yours truly Frank Schroder General info Eff length 239 3mm Pivot to spindle distance 222mm Overhang 17 29mm Offset Angle 232 Eff mass with supplied cartridge mounting plate 14gr 19gr with optional heavy cartridge mounting plate 12 5gr with ultralight cmp Shaft diame