1. Make sure you get a relay rated for higher continuous currents than your charger pulls from AC outlet so it doesn t get too hot Still you may need to mount it on a heat sink if it gets hot Low Voltage Cutoff LVC is temperature compensated Each module has a thermistor which automatically adjusts LVC for each cell which works well if some cells are installed in different locations in the car with different temperatures at each location LVC is set to 2 5V at OC temp 2 6V at 25C temp and 2 7V at 50C temp linearly adjusting itself across the entire temp range Green LED on each cell module indicates normal conditions i e cell voltage is between LVC and HVC levels All cells must have Green LEDs on during normal use When any cell goes below LVC or above HVC levels Green LED turns off and alert is created by open NC loop Optional shunt balancing has a maximum shunting current of 0 75 Amp Red LED comes on during shunting for visual indication Shunting slows down charging process on cells reaching HVC sooner than other cells allowing other cells to catch up This is referred to as top balancing Initial manual balancing is recommended so BMS can keep the pack balanced long term Head end control board is an interface between cell modules and charger and motor controller It uses simple NO NC connections to act on LVC and HVC events Control board senses alerts from NC loop and acts on those by reducing the throttle LVC and shu
2. AC relay to interrupt power to the charger HVC event will latch on so charger will not come back on when resting voltage goes below HVC NOTE In ideal world HVC function may not even interfere with the charger allowing it to finish CC CV charging phases as intended by charger s manufacturer However in case there enough misbalance across multiple cells such that one cell gets to HVC much sooner than others HVC will protect the cell by cutting off charging process prematurely It is up to you what action to take depending on how prematurely HVC cutoff occurs If charger is interrupted only a few minutes before the end of CV phase at which point charging current is very low then you are not losing much and you can simply let this happen every day If you have BMS with shunting option then shunting process will over time pull back this pesky cell and equalize it with others Or you can manually attempt to discharge that cell a little bit to bring it down in line with others You have many choices and MiniBMS is here to protect your battery investment even at the cost of somewhat incomplete charge You may soon realize that small amounts of charge at the end of the charge cycle are not all that important and not worth risking overcharge of individual cell 2 You must disconnect the charger before turning Ignition on Once ignition key is on BMS will reset HVC circuit to prepare it for the next charging cycle 3 Once Ignition key is on BMS
3. Kelly and others Check controller s documentation for details Do not use this diagram with Hall Effect throttles please refer to the following diagram for Hall Effect throttles If you are not sure which diagram works best for your conversion please contact MiniBMS support for assistance Throttle Assembly Loop H COM H NO MiniBMS Gnd Input 5V Control Board Buzzer Motor Controller Next diagram shows only motor controller portion of MiniBMS wiring diagram for 3 wire Hall Effect throttle Since Hall Effect device is powered by 5V input we must use voltage divider on the output side of the throttle to reduce its output level during LVC event Hall Effect Throttle Assembly Cell 5V Gnd Output H NC B Gnd Ign Ce Loop H COM H NO MiniBMS Control Board Buzzer Controller Below diagram shows how to interface LVC signal with popular Soliton1 and Soliton Jr controllers from EVNetics These controllers have 3 programmable inputs you can use any one of these inputs to interface with BMS then configure the input type in controller s Web interface BMS LVC input is ACTIVE LOW so normally BMS will pull it up to 12V using controller s 12V signal supply via 5K resistor When LVC event occurs BMS will pull the input down to Gnd which will cause controller to reduce its power using same behavior as if the pack voltage reached low limit H NC H com H NO B Gnd Ign Cell
4. expects LVC events During driving when your pack gets close to low charge levels BMS will sense LVC events from cells with smallest capacity This will initially happen during heavy acceleration due to deeper voltage sag 2 4 second delay is designed to filter out brief voltage sags which may happen while there is still plenty of charge in the pack However as you get closer to empty pack LVC events will become more frequent and prolonged which is an indication to the driver to get off the road ASAP If LVC alerts become solid with little or no throttle applied you have reached the lowest charge level and should not drive anymore It s possible that one or two cells are damaged or have significantly lower capacity than others causing LVC alerts when you don t expect them Check Green LEDs on all BMS modules to find offending cells which will have Green LED turned off during LVC event 4 Any lose wiring connections between cells and or head end control board will also cause LVC HVC alerts to bring your attention so you can find offending connection and fix it 5 Ina rare event when LVC alert is on solid you must keep the Ignition key on while turning on the charger This is necessary to prevent charger relay from false tripping since it can t distinguish LVC event from HVC event Within few minutes all cells will climb over LVC voltage and you can turn off ignition key and charger will remain running This situation is an extreme case and s
5. voltage input across Black Red control wires For newer style Elcon charger with 7 pin round connector which has its own voltage source use updated diagram below New style interface simply requires closure of Black Red wires to enable the charger to 12V battery to Ignition AC Power 120 240 VAC B Gnd Ign Cell H NC Loop BMS Input H COM Red wire Black wire Elcon PFC MiniBMS a k a Chinoz Control Charger Board to battery pack This diagram is for new style Elcon charger with 7 pin round connector which simply requires closure of Red Black control wires to enable the charger
6. Loop MiniBMS Control Board Signal Input Signal 12v 1 2 or 3 Gnd EVnetics Configure one of the inputs as BMS LVC Soliton1 in controller s Web interface or Soliton Jr Motor Controller Optional charger controls Some chargers have BMS input functions which turn off the charger based on ON OFF or specific voltage input You can wire such charger to MiniBMS control board without using high power solid state AC relay Please note that control board NO NC output has 2 Amp commutation current limits if you exceed it you may damage the relay Please check with MiniBMS support if you are not sure about this option See additional diagrams below for optional charger interface Auxillary 12V battery note MiniBMS relies on constant power supplied from your 12V aux battery Please make sure your 12V battery is properly charged at all times to ensure correct BMS operation For safety reasons MiniBMS will shut off the charging process if it loses 12V power to the head end control board which may leave you with undercharged pack unexpectedly MiniBMS takes less than 50 mA from 12V battery likely less than self discharge rate of typical Lead Acid battery but any failure of the 12V battery will result in BMS triggering HVC event so your traction pack will still be protected from potential overcharge even at the cost of premature charger interruption LVC safety note MiniBMS is designed to protect your battery pack from premature damage due t
7. MiniBMS User Manual Distributed version MiniBMS is a battery management system designed for LiFePo4 cells used in Electric Vehicles MiniBMS is designed to be reliable and cost effective solution it has most basic functions implemented via simple analog circuit and one wire interface which also allows easy installation and troubleshooting MiniBMS Features e Support for HiPower ThunderSky CALB SkyEnergy and other LiFePo4 cells Installs directly on cell terminals using included ring terminals One terminal has rigid connection supporting BMS module the other is connected via short wire This design allows installation on virtually any cell size BMS module is very small 48mm x 30mm and fits easily on most prismatic cells e Optional support for centralized installation with single board managing up to 16 cells Useful for smaller cell sizes and packs such as E bikes small cars etc You must select this option when ordering your BMS modules so they will not be cut into individual boards e Low profile Printed Circuit Boards with Surface Mount Components allows installation in tight spaces inside battery boxes etc Components are sealed from dirt and moisture safe to install under the hood of the car e Single wire Normally Closed NC analog communication loop All modules connect in a single series string using automotive style Quick Disconnect crimp terminals NC loop is extra reliable since it senses loose wiring connect
8. hould never be experienced unless you ignore LVC alerts and run your pack to empty DO NOT leave the Ignition key on unattended while charging it will disable BMS ability to turn off the charger when first cell reaches HVC level MiniBMS Wiring Diagram This basic diagram shows how to interface MiniBMS with your battery pack charger and motor controller This diagram shows motor controller with 2 wire resistive 0 5K pot box which is common for Curtis Logisystems and some other controllers 5K resistor shown in the diagram will be connected in parallel to the pot box during LVC event which will reduce total resistance to 2 5K which effectively clamps the throttle to 50 of max throttle You can manipulate resistor value if you wish to clamp LVC throttle to higher or lower levels Keep in mind that getting off road safely should be higher priority than saving few battery cells don t clamp the throttle too much so the car can keep driving at lower speeds MiniBMS Wiring Diagram to 12V battery to Ignition AC Power 120 240 VAC Solid State Relay 30 50 Amp B Gnd Ign Cell t Loop H NC Load H COM Control Resistor MiniBMS Control Motor Charger Board Controller Next diagram shows only motor controller portion of MiniBMS wiring diagram for 3 wire resistive pot box and controller which expects 0 5V throttle input Controllers which use this type of throttle input are Soliton1
9. ions as well as low and high cell conditions Analog NC loop is not affected by high electrical noise inside EV which has severe negative effects on digital communications Less than 7 mA operating current to prevent bleeding cells over long time period when not in daily use Resistors protect every part of the circuit from potential semiconductor failures Any component failure results in BMS alerts protecting the battery even from BMS itself PTC resettable fuse protects from overheating during shunting as well as short circuit conditions Fuse opens if temp reaches 80C or if shunting current reaches 1 Amp Open fuse results in same alert as full charge shutting down the charger Fuse returns to normal conditions automatically High Voltage Cutoff HVC HVC voltage level is selectable at the time of purchase for most popular cell types When first cell reaches HVC it will cause BMS to shut down the charger effectively protecting your battery pack Since BMS can control AC power to the charger you can use practically any charger with this BMS even dumb chargers without special LiFePo4 charging profiles This requires purchase of high current solid state AC relay not included with BMS If your charger has BMS shutoff input then you don t need AC relay This datasheet is an example of such AC relay http www teledynerelays com pdf industrial sh pdf You can find many others from various online electronic parts retailers including Ebay
10. lay is adjustable via trimpot on the head end control board Delay is designed to filter out false LVC alerts during brief voltage sags which are normal during hard accelerations When NC Loop connection is restored buzzer should turn off immediately It is not recommended to set delay more than 4 seconds to prevent deep discharge during LVC events To test charger connection to BMS after all charger connections are made turn on the charger and make sure it starts charging the pack normally Ignition must be off at this time so BMS can expect HVC signal Manually break NC Loop by disconnecting one of the wires After 2 4 second delay charger should turn off When you restore NC Loop connection charger should remain in off state until you cycle ignition key on and off It s a bit more difficult to test BMS connection to motor controller since it requires running motor to observe throttle reduction If your EV is drivable you can arrange to interrupt NC wire loop from the cabin using a temporary switch in line with NC wire loop to simulate LVC event After 2 4 second delay you should observe throttle reduction and buzzer alert In real LVC event throttle reduction will prolong your battery life so you can get off the road safely and prevent damage to your battery pack MiniBMS Operation i During charging Ignition key is off which tells BMS to expect HVC event When first cell reaches HVC voltage BMS will interrupt NC loop and cause charger
11. n connectors are very tight With enough force when pushing connector over the blade terminal you can lift the trace off the PCB and damage the connection recommend loosening up the connector a little bit with flat screwdriver before pushing it over the terminal 3 Wire head end control board according to attached schematics B terminal must come directly from the 12V aux battery to ensure BMS is powered while ignition is off during charging Ignition input is required to reset BMS after each charge When wiring to charger and motor controller please find most appropriate diagram for your type of charger and throttle assembly If you are not sure which diagram is best for you contact MiniBMS support and provide models of your charger controller and throttle assembly to get detailed wiring directions You can use any 12v low current Buzzer from Radio Shack or other retailers The more annoying it is the more inclined the driver will be to react on LVC alerts but it should not be deafening so the driver can pay attention to the road Buzzer current should not exceed 250 mA otherwise it will trip the fuse on the control board Mount the buzzer under the dash board or under the steering wheel so it can be heard clearly by the driver 5 6 To test head end control board after it s been wired manually disconnect one of NC Loop wires simulating BMS alert condition This should result in buzzer coming on after 2 4 second delay De
12. o overcharge and over discharge Specifically LVC function is carefully designed not to interfere with normal driving conditions until there is very little energy left in the pack You should not let your pack get to LVC alerts on regular basis and you should not rely on LVC alone to gauge your pack State Of Charge Using additional SoC instrumentation such as voltmeter or special SoC gauge is highly recommended to avoid reaching LVC levels on regular basis Know your range limitations and plan your route LVC is there to protect your battery even at the cost of leaving you stranded on the road First LVC alerts will come under heavy acceleration and indicate that you only have few minutes left to drive until your pack is empty Additional wiring diagrams for popular chargers with BMS Input Please note that not all Elcon a k a Chinoz chargers have the BMS input You would know about BMS input since you can t use the charger unless you apply control voltage on red black wires to 12V battery to Ignition AC Power 120 240 VAC B Gnd ign Cell H NC H COM H NO Loop MiniBMS Manzanita Control Charger Board to battery pack to 12V battery to Ignition AC Power 120 240 VAC r B Gnd Ign Cell Loop H NC H COM BMS Input Red wire Black wire Elcon PFC a k a Chinoz Charger MiniB MS Control Board To battery pack NOTE This diagram is for old style Elcon charger which requires external low
13. tting down the charger HVC Simple interface allows compatibility with virtually any charger and motor controller Head end control board supports piezo Buzzer to provide audible alarm for the driver when alerts are triggered by cell modules Any 12V low current buzzer from Radio Shack can be used MiniBMS Installation CRITICAL WARNING Make sure your battery pack is physically disconnected from the rest of your EV when attaching BMS modules to your cells Failure to do so may result in last BMS module completing the high voltage circuit before it gets attached to the last cell terminal This will damage the BMS module beyond repair and will not be covered by warranty 1 Install cell modules on each cell You MUST install BMS terminals on top of copper links but under the flat washer to make sure it won t be twisted when you torque the terminal bolt DO NOT install BMS terminals under copper links to avoid passing high currents thru the BMS terminal Thread both bolts by hand to secure both sides of BMS module before tightening terminal bolts Using 18AWG 16AWG wire and 0 25 Quick Disconnect crimp terminals fabricate wires to connect all cells in one series string Leave some slack on each wire to avoid stress if cells shift a little during use Signal connections are not polarized so you can connect in any order as long as wire loop goes thru all cells and both ends meet at the head end control board WARNING Push o

Download Pdf Manuals