Home

AQ7270 Brochure

image

Contents

1. Connection loss m ete Fiber under test Built in dummy fiber Trace Analysis Functions For Evaluation of Multicore Fiber For Accurate Splice Loss Measurement by Bi directional Testing Multi Trace Analysis 2 Way Trace Analysis Up to four traces can be overlaid Merges the two traces measured on the display for analysis and from both directions and finds the comparison correct splice loss This is useful for evaluating connection point locations and loss after installing multicore fiber Connection loss in lines where optical fibers of differing backscatter coefficients are connected can differ depending on the direction In such cases you can accurately determine the loss by measuring in both directions and taking an average For Evaluation of Aged Deterioration For Evaluation of Total Return Loss Differential Trace Analysis Section Analysis Displays the difference between Finds the total return loss in specific two specified traces portions of the fiber Makes it simple to check aged deterioration of fibers or connection points or fluctuation in loss between fibers and other phenomena This type of evaluation is often requested because the multiple reflections from optical fiber networks can affect signal light from transmitters cable TV etc Smart File Function Because the AQ7270 makes it easy to differentiate between measured optical fibers even complex one
2. aF A a Tr m i al Helps you to easily move the Front panel ee ee cursor and change parameters a f Moves to the main menu Also you can press the knob Bumper SI Keys You can select a variety of to toggle between fine and Protects the unit from Soft keys are used for measurement functions in coarse adjustment external shocks menu operation the main menu Essential for work in the field Cale N Switches between zooming in out on the trace or horizontal vertical shift YOKOGAWA A072700 OPTICAL PORT OFTEA TMF DONAN REFLECT OWE TEA 2006 1107 14 28 fwerage B8 10 LSA rrow Keys Enter Key These keys are used to select and enter items when setting conditions They can also be used for scaling in the OTDR trace display Move to the i gf aa d 1 r oy i si FEAL aye l measurement condition Loss dB Loss dE Loss a ne TOR eames i j gasis 0 146 ENTHE 1146 C settings menu B gba 8 1153 60 4065 6 349 1 12545 0 168 8 592 1 LAG 46 249 9 815 0 176 1 46000 erage ke ns E l A Starts stops measurement r Ga HIC AG iand beli CD dis play Escape key File ke Starts stops real time For carrying or holding 8 4 inch high intensity Escapes from menus Opens the file menu measurement during one hand TFT LCD with three operation brightness settings Side panel fi was To fix the unit when ona work bench Prin
3. Automatic Setting of Measurement Conditions Full Auto Mode Simply choose the measured wavelength then press a button The AQ7270 automatically sets the optimal measurement conditions performs measurement performs event analysis and saves data Because you can save to a different file name each time you execute measurement and accumulation of data is easy Press a button Full A Select wavelength Setting Test Analysis File save E Splice Retort Cunt ia te dik Eve TE SE ction Loess lB Loss id Loss toll Tye l LIUR Measurement with Auto Wavelength Switching Multi Wavelength Measurement Mode Prepare multiple wavelengths to measure then press a button Multi Wavelength Measurement is a mode in which multiple specified wavelengths from the same optical port are measured automatically in order You can also specify to perform analysis or file saving as needed for each measurement j F Wavelength switches automatically h T 1 J d _ he E st ee a r n METIL 1 ELTTI x nE im 2 7 i iaz ol Carat k i T 1 Tr 7 tra lah vent Dis Lance japl bot Crh L mt ere e p 7 0 of of bir zii i EA ee ey L TRL dL i a Oa ee 3 pry is p Th t a4 F i ity 1 T 3 if EI Macro s with Predefined Procedures One Button Mode Simply choose previously set measurement procedures then press a button
4. YOKOGAWA lt gt Optical Time Domain Reflectometer E i iil A i yam TRIB MG Unit Fy iL Dii Is i E OT pp a PLL EAEN Short dead zone 0 8 m Wide range of models available supporting FTTH to metro networks High performance amp easy to use OTDR Bright amp high contrast 8 4 inch LCD screen fiberX plorer www yokogawa com tm Bulletin AQ7270 01E w a m m 8 4 High intensity large LCD lt O06 4 1 39 14 04 z pez Meets a broad range of measurement needs from FITH to metrojnetworks f at a es D T j fine Button i Le A Ri onl Ot 1 HRON joe 9059 090s One Ae 190 AHO DOD c te Os 206 OAE FTTH FTTB Access networks Optical LAN WAN a aana E lt Optical power monitor screen mr A tie zy mi i din km peih SH 11b m em Use as an Optical POWermeter rower monitoring Function _ Using the power monitor factory option you can check optical power for link loss testing or when troubleshooting Useful for checking the optical power at the ONU s receiver in FTTH JE LN ead zone fat Dynamic r Fg Light source screen gt EEn cw iit Use as a Light Source Light Source Function lt zaan oldie 505 4a 34En The light source factory option can be used for optical fiber identification umeingia 164 00701km an s ce
5. You can execute up to five saved measurement procedures in order A batch of measurement procedures can be run directly from the main menu Measurement and analysis conditions can be read from a file making it easy to set up the measurement procedures Procedure 3 Procedure 2 j Procedure 1 Measurement Procedures Execute directly from the main menu Setting Setting Setting Test Test Test Analysis Analysis Analysis File save File save File save Measurement Wizard Assistance setting up measurements HBHRHRBRHRHRHE HEHEHE HEHE BERBER BERR RRR eR RE RRR eR eR eR eR eR RR RRR RE RE eR eR eRe eR eRe eR eRe eR eR eRe eee eee 2 es Displays detailed explanations of parameters in the measurement conditions setting menu and gives guidelines for setting methods This function assists unskilled users ACTIVE LINE ALARM Checking for communication light HBHRHRBRBRaHRaBHRaBHRaBRaBRaBRaHRaBRaBRaBRaBRHRaBRBREBRBRBRBRHBRHE HERE HBR BE HBR HEBER BR BERR BRR BE RRR RE RRR eR eR eR eRe eee eee 6 E Never disturb communication lines There may be concern that technicians inputting the OTDR measurement signal into the communication line could cause communication errors The live line alarm monitors the fiber s optical power level and diplays an alarm message if it detects optical power at or higher than a specified threshold level in order to warn the technician not to mistakenly feed the signal into the communic
6. AC adapter Rated supply voltage 100 to 240 VAC Rated supply frequency 50 to 60 Hz Power consumption Max 70 W when battery charging and optional printer printing Dimensions W 287x H 197x D 85 mm not including projections or options Weight Approx 2 8 kg not including options 1 Measurement for 30 seconds in every 10 minutes without any options in power save mode Full Auto 1minute 2 Ambient temperature of 23 C power OFF Laser Safety Label External Dimensions gt gt gt Specifications by Model Single mode Fiber 1 Wavelength Type Single mode Fiber 2 Wavelength Type 7 Wavelength _1310 1550 25nm _ 1550 1625 25nm _ Wavelength 1550 25nm 1650 Snm Wavelength 1310 1550 25nm 1310 1550 25nm_ 1550 1625 25nm 10nm Applicable fiber SM ITU T G 652 ee tus 2us 5us 10us 20us 500ns tus 2us at 10us 20us 30B Event dead zone gt Attenuation dead zone 7 8m typ 7 8m typ 8 12m typ Attenuation dead zone 8m typ 12m typ Fiber 3 Wavelength Type Wavelength 1310 1490 1550 25nm 1310 1550 1625 25nm fao 1550 25nm 1310 1550 1625 25nm 1650 5nm 1 10nm 2 Ap plicable Applicable fiber SM ITU T G 652 500m 1km 2km 5km 10km 20km 50km 100km 200km 300km 400km Pulse width 3ns 10ns 20ns 50ns 100ns 200ns 500ns 1us 2us 5us 10us 20us 34 30 32dB 34 32 28dB 34 32 30dB 40 38 35dB Event dead zone Attenuation
7. 0 00477kn E nvdiv _ SHP 5en Choose an Ideal OTDR 11 Moie Lineup Measure Near ws O Far Promi io dagaseiendih models Can detect closely spaced events up to 0 8m High dynamic range up to 40dB The AQ7270 comes in eleven models combining different measurement wavelengths and dynamic ranges Supported wavelengths 1310 1490 1550 1625 1650 nm single mode 850 and 1300 nm multi mode Accompanying the rapid proliferation of FTTH is a growing The high dynamic range of the AQ7270 enables accurate need for detection of reflective events arising from short measurement of optical fibers in short periods of time This Typical Model distance mechanical connections The AQ7270 s event makes it a powerful tool for evaluation of metro networks i i i i i i i Applicable Number of dead zone is the shortest in the world enabling detection of with relay distances in excess of 100 km or FTTH PON ee Wavelength Dynamic Range Model Des rptons o closely spaced events and other short optical fiber networks with large insertion Iber avelengths Based on company research of the field use OTDR as of November 2006 loss originating from optical couplers 1550nm 32dB 735020 Sere 34 320B_ 735022 2 40 38dB_ 735023 SME 1550 1625nm 38 35dB 735024 Supporting maintenance wavelength 1625nm Three wavelength model for installation and maintenance of PON systems 3 34 32 28dB 735026 _ Three wavelength model supporting a m
8. dead zone 7 8 8m typ 7 8 12m typ 7 8 12m typ 7 8 12m typ Multimode Fiber 2 Wavelength Type Multimode Single mode Fiber 4 Wavelength Type Model 135029 Vio 735030 Wavelength 850 1300 30nm Wavelength 1310 1550 25nm 850 1300nm 30nm Applicable fiber GI 50 125 62 5 125um Applicable fiber SM ITU T G 652 GI 50 125 62 5 125um 500m 1km 2km 5km 10km 500m 1km 2km 5km 10km 20km 500m 1km 2km 5km 20km 50km 100km 50km 100km 200km 300km 400km 10km 20km 50km 100km h37 10ns 20ns 50ns 100ns h3 3ns 10ns 20ns 50ns 100ns 200ns 10ns 20ns 50ns 100ns 200ns Puise width 200ns 500ns 1us 2us 5us PURSE ANIGNN 500ns 1us 2us 5us 10us 20us 500ns tus 2us 5us 22 5 240B 34 3208 22 5 240B Event dead zone _ 2m typ Event dead zone 2m ype Attenuation dead zone 7 10m typ Attenuation dead zone 7 8m o t 7 10m typ 1 N oR OW At a point 20 dB from the pulse light output peak value measured 30 min or more after power ON 6 Pulse width 10 ns return loss 45 dB or more at a point where the backscatter level is within 0 5 dB of the ambient temperature of 23 C normal value At a point 60 dB from the pulse light output peak value measured 30 min or more after power ON 7 Pulse width of 2 or 5 us when measured wavelength is 1300 nm ambient temperature of 23 C 8 SNR 1 at pulse width 200 ns 850nm 1 us 1300nm measurement time 3 minutes Pulse wid
9. fiber option may cause the reduction of dynamic range 0 5dB or less Modulation frequency CW 270 Hz Wi AQ7270 OTDR Option availability Description AQ7270 OTDR 1550nm 32dB AQ7270 OTDR 1650nm 30dB AQ7270 OTDR 1310 1550nm 34 32dB AQ7270 OTDR 1310 1550nm 40 38dB AQ7270 OTDR 1550 1625nm 38 35dB AQ7270 OTDR 1310 1490 1550nm 34 30 32dB AQ7270 OTDR 1310 1550 1625nm 34 32 28dB AQ7270 OTDR 1310 1550 1650nm 34 32 30dB AQ7270 OTDR 1310 1550 1625nm 40 38 35dB AQ7270 OTDR 850 1300nm 22 5 24dB AQ7270 OTDR 850 1300 1310 1550nm 22 5 24dB 34 32dB 1 Does not support the 1650nm port 2 Does not support the 850 1300nm port Available Not available Connector Optical power monitor GB standard Complied with CCC Built in printer LAN DF SB Example 735023 USC HE D PM LS AQ7270 OTDR 1310 1550nm 40 38cB with Universal adapter SC English version with a UL CSA standard power cord with power monitor function and with Light source function Dummy fiber SMF Sholder belt fi Standard Accessories An AC adapter a power cord a battery pack a hand belt and a set of users manual CD ROM YOKOGAWA Model and Suffix Codes Accessories Optional Soft carrying case Battery pack Universal adapter SC Universal adapter FC Printer roll paper Shoulder belt AC adapter SC type FC type 80mmx25m UL CSA standard VDE standard AS standard BS standard GB standard C
10. from a file to be used as the reference waveform SETUP KEY Jump to measurement condition setting menu HBHRHHRHRHRHEHBERHE HEHE HEHEHE BEBE BR RE BER RR RE RRR RRR RR RR RR RR RRR RR RRR eR eR eRe eRe eee eee ee With the new SETUP button on the front panel it is easy to move to the measurement condition setting menu fovea eu istanee sp i eane tir Distance Splice Return Cumulate dB km Event Section km Loss dBi Loss dB Loss dB Type IOR 6 44564 0 783 2 6067 _T 1 48606 1 48666 1 48000 Aeasurenent Wizard e Wave length i bistance Range SH 1558nnA Distance Range Please select a distance range suitable for the cable to be tected Auto Unknown D n Gm to Hii ikm 400m to P r gt j n to 1 6en 1 6ke bo 4km H Jka to Oka 2 ka to I6k dbke to 40kr ike to BOkA BOkR to i k z ib ka bo Zd km Akn to 4th Measurement Wizard Menu LASER OH ActiveLine Check Sib 113 2209 Active Line Alarm The connected fiber may be in wee oui you like to comt ime Active Line Alarm Message Error Code 510 PLUG CHECK Error Please check or clean the connector Press ESC key to clear Plug Check Alarm Message Fault event Fault Event Indication on the waveform Reference waveform Measured waveform Trace Fix Function ans 8 a n f Bright 8 4 in ch LC D Screen tasto Operate with Rotary knob amp Arrow Keys
11. ION Communication amp Measurement Business Headquarters 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Phone 81 422 52 6768 Fax 81 422 52 6624 E mail tm cs jp yokogawa com Represented by Subject to change without notice All Rights Reserved Copyright 2006 Yokogawa Electric Corporation Ed 02 b Printed in Japan 702 KP
12. V format Reports are easy to create by following the step by step instructions in the report wizard Note Operating System Microsoft Windows 2000 XP Excel Microsoft Excel 2000 XP 2003 Specifications gt gt gt Common Specifications Horizontal Axis Parameters Sampling resolution 5 cm 10cm 20 cm 50 cm 1m 2 m 4m 8m 16m 32m 1 cm Min Up to 50 000 points Readout resolution Number of sampled data Group refractive index 1 30000 to 1 79999 in 0 00001 steps Unit of distance km kf or miles Distance measurement accuracy Offset error 1 m Scale error Measured distance x2 10 Sampling error 1 sampling resolution Vertical Axis Parameters Vertical axis scale 0 2 dB div 0 5 dB div 1 dB div 2 dB div 5 dB div 7 5 dB div Readout resolution 0 001 dB Min Loss measurement accuracy 0 05 dB dB When the measuring loss is 1dB or less the accuracy is within 0 05dB OTDR Measurement Function Distance measurement Displays up to eight digits of the relative one way distance between two arbitrary points on the trace Displays one way loss in steps of 0 001 dB to a maximum of 5 digits Displays the one way loss loss per unit length and splice loss between any two given points on the waveform Measures return loss and total return loss of a fiber cable or between two arbitrary points on the trace OTDR Analysis Functions Analysis functions Multi trace analysis 2 way
13. aintenance wavelength of 1625nm 1310 1550 1625nm i i i d F f Now measurements can be started quickly upon arrival at the site 10 40 38 35dB 735028 ae Pere Bere SRO nec up po lm ng Generative coe GHG FASE seconds to powerup from completely OFF t fully ON With such a fast ume 2 oom 2252408 power up time battery life can be extended by turning the power off while not a UIn a 0 mode ber inode Hen Es alnlenanee Powers up quickly in use at the job site without any concern about the power up time when the MMF SMF 850 1300 1310 1550nm 34 32 22 5 244B 735030 Four wavelength model for installation and maintenance of LAN and FTTH in 10 seconds or less next job is ready It s ready when you re ready UN a uel Wet IMU Luvetels elie alee ee Ure The worldwide spread of broadband services has stimulated the installation of optical fiber in metro and access networks which in turn has increased the demand for portable and reliable test equipment to aid the installation and maintenance of these networks Our new OTDR has been developed to address these challenges with particular aims of improving operability to boost work efficiency and cost effectiveness The AQ7270 carries forward the basic operation of its predecessors the AQ7250 and AQ7260 OTDR while adding a Detail mode for trained technicians with functions for setting of measurement conditions and performing manual measurements J a gt d fi d gt g g gt
14. ation line PLUG CHECK FUNCTION Checking the connection with the OTDR Never spoil measurements with poor connections or dirty plugs The plug check function monitors the condition of the OTDR s optical input output connectors and displays an alarm if the connection is not properly made This function is useful for checking for damage dirt or other problems with optical plugs at the OTDR or on the fiber under test and for helping technicians to remember to connect the fiber under test Detecting Abnormal Events Fault Event Display Function HBHRHBRHRHRHEHERHEHER HEHEHE HERE BERR BEBE RR RR RR RP RR RRR RRR RRR RRP eR RE RRP eR eR eR eRe eee eee ee The fault event display function detects abnormal connection or reflection points and displays them Of the events detected by the event detection function abnormal events that cross a specified threshold value are highlighted in the event table and waveform display 6 672 6 64975 6 649 56 511 6 692 6 449 hb 1 41685 lt 46 8558 1 340 6 324 M Analysis results with Fault Event Display Measurement with Comparison to Reference Waveform Trace Fix Function You can freeze the display of one trace and overlap it with real time or averaged waveforms for comparison This is useful to create a template when installing multicore fiber or for checking aged deterioration during maintenance on existing fiber networks In addition to the last measured waveform a waveform can be loaded
15. n printers easily transfer saved data to a PC or other device You can easily access to internal memory with USB cable from a PC The AQ7270 can be remotely controlled from an external PC by connecting a USB cable from one to the other m a USB type A type B cable required for remote control Measured Data Analysis and Report Creation Tool AQ7932 OTDR Emulation Software Sold Separately AQ7932 is application software that performs analysis of trace data measured by the AQ7270 OTDR on a PC and creates reports The report creation wizard makes this task simple AQ7270 OTDR data can be easily loaded onto a PC using USB memory or the communication interface W Trace Analysis You can edit event search conditions approximate curve line settings and other conditions and then repeat the analysis And now it is even easier to operate simply click the function icon with the mouse E Analysis Functions Display up to eight traces on screen and perform a variety of different analyses including multi trace analysis differential trace analysis for comparing recent waveforms with old ones and 2 way trace analysis function for analyzing average values of data measured from both directions in the optical fiber 1s Ee T i ri ll n i J Lg Pe E Creating Reports Compiles trace and measured values from trace files and creates a report Reports can also be created in Excel or CS
16. omplied with CCC Application software Specifications AQ7932 OTDR Emulation Software Ver3 0 or later Model EN _ Engish S Related Products OTDR LD Light Source AQ 260 AQ42 0 01 High performance OTDR that also Compact lightweight 1310 1550 nm 2 supports long distance optical fiber wavelength light source with 4 switches for cables with high dynamic range of up to easy safe operation 45 dB Optical Powermeter Optical Powermeter AQ2160 01 Compact lightweight powermeter designed especially for absolute value measurements for FTTH LAN work AQ2160 02 Compact light weight body Using with a light source it can measure optical loss Measured values can be saved to internal memory making on site work more efficient Microsoft MS and Windows are registered trademarks or trademarks of Microsoft Corporation in the US and other countries YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan Georgia 30265 1094 U S A Phone 1 770 253 7000 Fax 1 770 251 6427 YOKOGAWA EUROPE B V Databankweg 20 3821 AL Amersfoort THE NETHERLANDS Phone 31 33 4641858 Fax 31 33 4641859 YOKOGAWA ENGINEERING ASIA PTE LTD 5 Bedok South Road Singapore 469270 Phone 65 62419933 Fax 65 62412606 YOKOGAWA MEASURING INSTRUMENTS KOREA CORP Phone 82 2 551 0660 Fax 82 2 551 0665 YOKOGAWA SHANGHAI TRADING CO LTD Phone 86 21 5405 0303 Fax 86 21 6880 9254 YOKOGAWA ELECTRIC CORPORAT
17. s you can add arbitrary information to file names such as measured wavelength ID number tape number or comments You can also have the ID number or tape number automatically updated and saved after each measurement Trace data can be saved in SOR and CSV format Also you can save screenshots as BMP JPG or PNG files TRB or TRD files saved on Yokogawa s previous AQ7250 and AQ7260 models can also be loaded File name setting screen Automatic updating of file names Concept of the file name structure 1310nmYokogawa5a sor D Tape No change 1310nmYokogawa5db sor De Tape No change 1310nmYokogawa5dc sor pr Tape No change af To 1310nmYokogawa5d sor ID number P 1310nmYokogawa6a sor Tape fiber Tape number File Nane ID number amp tape No change LT ene inhiyawaSa SOK Comment cable name etc Fiber NO CYAAN CO fd le ee Language Selection In addition to English standard you can select a display language of French German Chinese Korean Russian and others USB Function USB connectivity makes it more convenient to output to external memory or printers and to set up communication The AQ7270 comes standard with two USB1 1 compliant connector ports Type A and Type B e Saving Files to USB Memory Type A e Printing on an External Printer Type A Using USB memory or a USB You can print screen images or hard disk you can save large measured data on USB amounts of data Also you ca
18. ter paper feed button Built in printer Prints the Ethernet connector measured results or screen display Used for remote control and FTP File Transfer Protocol OTDR optical I O port Printer paper lock lever Slot for mounting the accessory battery pack A port for connecting to an Connector for the ical A port for connecting external PC for remote accessory AC adapter light l external memory or an control or accessing the external printer OTDR s internal memory 2006 11 07 14 28 Average 60 10 LSA 45195kn Distance Splice Return Cumulate dB km Event section ype IOR 9 217 I 1 46008 168 0 5247 L 1 456000 46 249 0 6815 6 176 1 46000 Built in Dummy Fiber Factory Option Excellent for detecting faults in fiber patch panels Fibers in offices frequently involve short distances between connectors By using the dummy fiber you can check whether there is any abnormal near end connection loss Also by measuring the connection loss at the near end connector you can determine the total fiber loss including that of the connector 7 3 Measurement connections in an office Office Optical fiber cable To office external network o REAR UII To external JO ae Oe Patch panel __ network r Patch panel ileke F gt Fiber connection point marker position 4 Dummy fiber Transmitter Sbp 2
19. th setting range depends on the distance range 9 Pulse width 10 ns return loss 45 dB or more at a point 1 5 dB below the peak value not satunated SNR 1 at pulse with 20 us distance range 200 km sampling resolution 32 m measurement time 3 minutes 10 GI 62 5 125 um is measured Pulse width 3 ns return loss 45 dB or more at a point 1 5 dB below the peak value not saturated 11 At group refractive index 1 5 12 Pulse light output power at 1650 nm less than 15 dBm Note Specifications without any special remarks assured at 23 2 C gt gt gt Factory Installed Option Specifications Built in Printer LAN Functions PL option Power Monitoring Function PM Option Printing method Thermal line dot Optical port OTDR optical I O port Dot density 576 dots line Measuring range 50 to 5 dBm Paper width 80 mm Measurement accuracy 0 5dB Operating environment Temperature 5 to 35 C Humidity 10 to 80 RH no condensation 1 CW light wavelength 1310 nm absolute max input level 0 dBm 1 mW Storage temperature 20 to 60 C 2 When inputting CW light wavelength 1310 nm 10 dBm at 23 2 C LAN function 10BASE T 100BASE TX RJ 45 x1 Light Source Function Option LS Dummy Fiber DF Option Optical port OTDR optical I O port Optical fiber Single mode fiber ITU T G 652 Center wavelength OTDR s center wavelengths Length approx 100 m Output level 5 dBm or more at 23 2 C Output level stability 1 dB 5 minutes Dummy
20. trace analysis differential trace analysis section analysis Loss measurement Return loss measurement Internal Memory 1000 waveforms or more Can store measured waveforms and measurement conditions DIE Display 8 4 inch color TFT LCD Total number of pixels 640 horizontal x 480 vertical Memory capacity The LCD may contain some pixels that are always ON or always OFF 0 002 or fewer of all displayed pixels including RGB and is not indicative of a general malfunction External Interface USB USB1 1 Type A and Type B one each Type A For external memory or external printer Type B For connecting to an external PC for remote control or access to the OTDR s internal memory ES Optical I O port Connector type SC fixed FC fixed SC universal adapter FC universal adapter No universal adapter base Number of port 1 or 2 Port 2 is only for model 735027 1650nm and Model 735030 850nm 1300nm File Formats Read SOR TRD TRB SET Write SOR Telcordia SET CSV BMP JPG PNG File formats General Specifications Laser safety standards class 1 M IEC60825 1 2001 Safety standard EN61010 1 Emission EN61326 Class A Immunity EN61326 Annex A Operating environment 0 to 45 C Temperature 0 to 35 C when charging the battery Humidity 85 RH or less no condensation Storage temperature 20 to 60 C Battery Operation time 6 hours Recharge time 5 hours

Download Pdf Manuals

image

Related Search

Related Contents

Philips AC4113/00 air filter  D4-500 digital power amplifier user manual    Mode d`emploi, Balances Pharmacy, Modèles PHL  Mode d`emploi du parcours asile  Instruction Manual  Descarga  Pioneer KEH-P5950 User's Manual  Transmodulador Digital Transparente TDT+  Sika®FerroGard®-901 - Distribuciones Villamar  

Copyright © All rights reserved.