Home

VTH15 Series User`s Manual

image

Contents

1. 261 221mm 154 181mm 262 200mm 136 CI mm 25mm mm 25mm mm 24mm Imm 25mm mm i6mm Imm 22 mm CI 0 8 kg Note e This manual is for reference only Slight difference may be found in user interface e Allthe designs and software here are subject to change without prior written notice e Alltrademarks and registered trademarks are the properties of their respective owners e If there is any uncertainty or controversy please refer to the final explanation of us e Please visit our website or contact userr local service engineer for more information
2. Menu The product main interface has four menus Video Talk Security Message and Settings See Figure 2 1 ARE Y Video Talk Message Settings Figure 2 1 VTH15 series Icon Name Note Network It means network connection is normal connection icon VTO not It means device does not connect to any connected VTO DND icon It means device enable DND do not ry 3 Ge disturb function SD card icon It means device has SD card inserted Missed icon It means user has missed message 2 1 2 Video Talk 2 1 2 1 Call User This function is used for VTH to call VTH a aa Call User Step 1 Click on BETO Input room no of user to call i e Building 1 Unit 1 Room 101 is 1 1 101 press i icon to call When the user being called answers the call user can have a bidirectional talk See Figure 2 2 Video Talk A Zz Call User CK Monitor e Records MA Call Center Pls input the room Number For example Building 1 Unit 1 Room 101 input 1 1 101 Figure 2 2 Step 2 Click on B contact book icon user can call add edit and delete contacts Note If both the two indoor door stations are VTH CM models with front camera then you can perform a bidirectional visual talk See Figure 2 3 OR Video Talk A Unit Door Station Fence Station 8 Call User CH Monitor Main VTO ej Records 3 d Call Center Figure 2 3 2 1 2 2 Monitor LR i Click
3. Resistive Support touch screen CS VTH1560CS Not support Capacitive Support touch screen VTH1580CS Not support Capacitive Support touch screen 1 2 Front Panel The front panel of the series product is shown in Figure 1 1 VTH15 Series A Model Figure 1 2 VTH15 Series AH Model Figure 1 3 VTH15 Series AS Model Figure 1 4 VTH15 Series AS H Model Figure 1 5 VTH15 Series B Model Figure 1 6 VTH15 Series CH Model and Figure 1 7 VTH15 Series CS Model a BEE a 3 2 oll Power Net Info DN sos Menu Call Monitor Unlock Figure 1 1 VTH15 Series A Model Figure 1 3 VTH15 Series AS Model Figure 1 4 VTH15 Series AS H Model 1e 00 Menu Figure 1 5 VTH15 Series B Model Figure 1 6 VTH15 Series CH Model Note VTH1520 model has front camera and other models do not have front camera Power Into 0060000000000 600000000000 600000000000 600000000000 60 0604000000000 600000000000 600000000000 600000000000 600000000000 600000000000 600000000000 600000000000 0m 00 0 CH SOS Menu Call Monitor Unlock Figure 1 7 VTH15 Series CS Model Different models of VTH may have slightly different button locations but same silk screens still correspond to the same function See Figure 1 8 and Figure 1 9 SSES Menu Call Monitor Uniock Figure 1 8 a SOS Q Arm Y Call Monitor ei Un
4. User Name Password Save o o o o Vv Figure 2 14 Step 2 Click on Save Step 3 In homepage click on talk to view added IPC video Clean Click on Clean to lock screen and now you can clean the screen Default Click on Default to restore system default settings SD card Click on SD Card you can view SD card free space or format SD card Note Password to enter SD card setting interface is the user password which is initially 123456 Touch Ring Slide O ON means touch sound is on OFF means touch sound is off Auto Capture Snapshot Slide A ON means snapshot is on OFF means snapshot is off 2 1 5 2 Project Settings Click on lat Ee this function is for installer user only The entry password is 002236 2 1 5 2 Introduction Click on Introduction you can view this product and problems might encounter during usage See Figure 2 15 CH E System Settings N Ke ge User Settings VTH15XX series is a well designed 7 inch digital building bidirectional talk product integrating monitoring A Project Settings bidirectional talk unlocking functions Introduction Embedding Technology further stabilize the system Whole IP subnet abundant function extension SNMP Network Manager Technology more convenient system management Network Encryption Technology safer data transmission Figure 2 15 2 2 Unlock When VTH is being called monitored in call status press unlock button
5. or unlock icon on VTH to remotely unlock door 2 3 Arm Disarm Disarm Status Press arm icon in homepage select one mode out in sleep and custom In pop up box input arm password default password is 123456 See Figure 2 16 Out Mode Arm Please input arm password Figure 2 16 e f you select delay then system will enter armed status after the delay period e If you select immediate arm then system will enter armed status when audio prompt ends Arm Status Press disarm icon in the lower right corner of homepage Input disarm password default password is 123456 If the password is correct system will say disarmed successfully If the password is incorrect system will ask you to try again 2 4 Screen Calibration The product is calibrated before shipped out from factory and if you want to calibrate the screen press unlock arm menu button to enter calibration interface Calibrate the screen according to the tips Appendix 1 Technical Specification ree 7 inch TFT full real color Dimension perating Mode Mechanical button SOS arm menu call monitor unlock touch screen echnology Input Alarm Input Support 8 channels alarm input 1 ch local Alarm Output N A alarm output Ethernet 10M 100Mbps self adaptive Protocol WF Power DC 10 15V or AV direct supply P GE Standby lt 1 5W Working lt 7W Consumption Working 10 C 60 C Environment 10 90 RH re 221mm 154 221mm 154 192mm
6. Alarm DS DS Area 2 Smoke Sensor NO Instant Alarm DS DS Area Urgency Button NO Instant Alarm 0S 05 Area4 Door Sensor NO Instant Alarm DS DS Area b Stolen Alarm NO Instant Alarm 05 DS Area 6 Perimeter NO Instant Alarm 05 DS Area 7 Doorbell NO Instant Alarm 05 DS Area 8 IR NO Instant Alarm 05 05 Figure 2 6 You can set bypass and delete for 4 8 channels to disable area for one time or long term 2 1 3 2 Alarm History i Records Click on Records and it records alarm time area no and event Meantime alarm info will be simultaneously uploaded to management platform When each channel has alarm there will be a 15s alarm locally plus a pop up alarm interface 2 1 3 3 Mode Setup Click on MEERE set area alarm mode including Out mode In mode Sleep mode and Custom mode See Figure 2 7 CH E Security Alarm A Out Mode In Mode Sleep Mode Custom Mode Area Status B Records Im Mode Settings Figure 2 7 Note Password to enter mode setup page is the user password and default password is 123456 Refer to Ch 2 1 5 2 1 4 Info Search In homepage click on Info Search to enter Info Search interface 2 1 4 1 Publish Info Click on Les El MAS you can view delete and clear information published VTH receives information from the center and indicator will turn on cH EL Info Search A Content Occurrence Time Publish Info lt G Guest Message ias Video Pictures Delete Delete All
7. Figure 2 8 2 1 4 2 Guest Message DS SE Click on nz user can view guest message with time and location on VTH 2 1 4 3 Video Pictures Step 1 Click on CSG TEEN user can view video and picture during monitoring and talk on VTH Step 2 Click on Records to view delete and clear records See Figure 2 9 CH E Info Search A Records Pictures MB Publish Info 01 VTO10116901 2014 04 01 13 58 36 Guest Message 02 VTO10116901 2013 09 12 15 26 30 Banna Delete Delete All Figure 2 9 Step 3 Click on View to play record See Figure 2 10 You are viewing 10716901 2013 11 20 13 50 15 00 00 05 00 00 05 SITT w Figure 2 10 Step 4 Click on file to view delete or clear pictures Note O AutoCapture On VTH project setting interface enable function When VTO calls VTH VTH will take three photos automatically and save them to local SD card Only Some models support this function 2 1 5 System Settings In System Settings interface user can set screen brightness incoming ring alarm ring talk time DND time and etc The following introduces the most commonly used functions User 2 1 5 1 User Settings Click on u User Settings you can set password ring talk DND local IPC clean touch ring SD card and snapshot plus restore default settings See Figure 2 11 cF X System Settings GI 3 User Settings lt N Password Displa Rin a me E 3 A Project Settings Introduction CET O
8. NO mw Local IPC Default E SD Card d Touch Ring QS O AutoCapture Qi Figure 2 11 Password Step 1 Click on Password You can set user password unlock password arm password and anti hijack password See Figure 2 12 Password Settings x UserPwd Unlock Pwd Arm Disarm Pwd Anti hijack Pwd Figure 2 12 User password initially is 123456 Unlock password initially is null Arm password initially is 123456 Disarm password initially is 123456 Anti hijack password initially is 654321 Note Some series has the same password for arming and disarming Step 2 Click on OK when you complete Display Click on Display You can set screen brightness and screensaver via and EN Ring Click on Ring You can set call ring and alarm ring via and em Talk Step 1 Click on Talk You can set ring call time monitor time record time and message time of VTO and VTH See Figure 2 13 EE Talk Settings xX VTO Ring Time 30s VTH Ring Time 30s VTO Talk Time VTH Talk Time _ 120s 30m np Monitor Time Record Time 30s 4 30s VTO Message Time Cancel Figure 2 13 Step 2 Click on increase time click on Em to decrease time Unit is second Step 3 Click on OK DND Click on DND to set do not disturb time Unit is hour Local IPC Step 1 Click on Local IPC You can set IPC name address username and password See Figure 2 14 Local IPC X IPC1 Name IP Address
9. VTH15 Series User s Manual V3 2 0 Table of Contents 1 General Introduction ancora 4 1 1 Mod l Kiel AAA anna 4 1 2 Front Panel sea ee ee ee 5 1 3 Re r EE 11 2 Product Ee 14 2 1 Basie F NELON EE 14 SMA d EE 2 1 2 Video WE EE 2 o e PA e nn o O eters 2 1 5 o PAP ee e 26 A an 26 2 4 Screen Calibration NEE 27 Appendix 1 Technical Specification runn44ssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ern 28 Important Safeguards and Warnings Please read the following safeguards and warnings carefully before using the product in order to avoid damages and losses Note Warning Do not expose the device to lampblack steam or dust Otherwise it may cause fire or electric shock Do not install the device at position exposed to sunlight or in high temperature Temperature rise in device may cause fire Do not expose the device to humid environment Otherwise it may cause fire The device must be installed on solid and flat surface in order to guarantee safety under load and earthquake Otherwise it may cause device to fall off or turnover Do not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not place any object on the device Do not disassemble the device without professional instruction Please use battery properly to avoid fire explosion and other dangers Please replace us
10. ed battery with battery of the same type Do not use power line other than the one specified Please use it properly Otherwise it may cause fire or electric shock Special Announcement This manual is for reference only All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website for more information 1 General Introduction 1 1 Model List This manual is for the following product models please carefully check your model and corresponding functions VTH15 Series Model Front Screen SD Card Camera A VTH1510A Not support Resistive Not support touch screen VTH1520A Not support Resistive Support touch screen AH VTH1510AH Not support Resistive Not support touch screen VTH1520AH Not support Resistive Support touch screen AS VTH1510AS Not support Resistive Not support touch screen VTH1520AS Not support Resistive Support touch screen AS H VTH1510AS H Not support Resistive Not support touch screen VTH1520AS H Not support Resistive Support touch screen B VTH1550B Not support Capacitive Not support touch screen VTH1560B Not support Capacitive Support touch screen CH VTH1550CH Not support Capacitive Not support touch screen VTH1520CH Support
11. lock Figure 1 9 No Name Note 1 SOS Emergent call to center 2 Arm Menu Press this button to return to main menu or arm 3 Call Under calling status press this button to answer call During a call press this button to hang up 4 Monitor Monitor VTO video 5 TEE During incoming call calling monitoring status press this button to unlock No Indicator Description Name 1 Power Indicator turns on when power is normal 2 Info Indicator turns on when there is missed call alarm or announcement Otherwise it remains off 1 3 Rear Panel Make VTH15 Series AH model and CH model as examples Ports of VTH of different models may have different locations but corresponding ports functions stay the same Figure 1 10 VTH15 Series AH Model No Name Note 1 8 ch alarm may connect to external alarm extension Alarm port module refer to label for details 2 Debug port For installation staff use only 3 Network port Plug in network cable 4 Handset port For model with handset only 5 Power port Connect to 2 pin plug 12V Figure 1 11 VTH15 Series CH Model No Name Description 1 Alarm Port 8 ch alarm please refer to tag 2 Debug Port Extension port for RS485 communication port 3 Network Port Plug in network cable 4 Note SE Reserved port 5 Power Port Connect to 2 pin green 12V power supply 2 Product Function 2 1 Basic Function 2 1 1 Main
12. on Monitor you can monitor unit VTO fence station or IPC 2 1 2 3 Call History Click on le Records you can view missed call answered call and called call See Figure 2 4 OR Video Talk CH Missed Call Accepted Call Called amp Call User LH Monitor 10116901 2014 02 13 17 27 24 Records 10116901 2014 02 13 12 10 41 10116901 2014 02 13 12 04 05 10116901 2013 09 13 10 00 29 2 Call Center Delete Delete Al Figure 2 4 2 1 2 4 Management Center gt Click on MUSA or press Emergency button and it is to call MGT center 2 1 3 Security In homepage click on Security to enter Security interface 2 1 3 1 Armed zone Step 1 Click on AREA interface shows current 8 ch area status including Area Type Current Status and Delay Time See Figure 2 5 CH El El Security Alarm Area No Area Type Current Status Delay Time Area 1 Urgency Button Instant Alarm 0S 0S Area 2 Gas Sensor Instant Alarm 0S 0S E Records Area 3 Smoke Sensor Instant Alarm 05 05 lm Mode Settings Area 4 Instant Alarm 0S 0S Area 5 Instant Alarm 05 05 Area 6 Instant Alarm 0S 0S Area 7 Instant Alarm 0S 0S Area 8 Instant Alarm 0S 0S Bypass Remove Refresh Figure 2 5 Step 2 Click on Set input password to enter area setting interface See Figure 2 6 Note The entry password is user password Default password is 123456 please see Ch 2 1 5 AreaNo R NO NC Alarm Enter Delay Exit Delay Area 1 Gas Sensor NO Instant

Download Pdf Manuals

image

Related Search

Related Contents

MyFax User Guide    CA ARCserve Central Reporting  Wacker Neuson  Samsung GT-S5302 راهنمای محصول  Template BA B168xH238    BEDIENUNGSANWEISUNG  。BDーーコネクタ一 46-3002  1309685 ENGLISH MANUAL 简化版.cdr  

Copyright © All rights reserved.
Failed to retrieve file