1. e Operating Steps Indication of the lock Touch the infrared sensor hole to power Fingerprint sensor is power on the lock 7 4 LED blinks green Press button lt One beep Place any admin finger 1 time to verify Admin ctun One beep Press button 2 to select normal user group Da One beep Place one finger 3 times on the One Beep for the first two fingerprint sensor ps fingerprints A long beep and LED blinks green 1 second for the third fingerprint Registration Succeed Register NEW users Note 1 Normal User group supports 60 users 2 The operating steps of Register new users Press button 1 2 3 to select user group then place one new finger 3 times on the fingerprint sensor to continue register new user Register Temporary User Operating Steps Indication of the lock Touch the infrared sensor hole to Fingerprint sensor is power power on the lock on LED blinks green gt Press button Place any admin finger 1 time to verify Admin cm One beep Press button 3 to select Temporary user group One beep Place one finger 3 times on the One Beep for the first two fingerprint sensor N fingerprints A long beep and 4 LED green 1 second for the third fingerprint Registration Succeed Register NEW users Note 1 Temporary User group supports 20 users 2 The operating
2. steps of Register new users Press button 1 2 3 to select user group then place one new finger 3 times on the fingerprint sensor to continue register new user se Delete Temporary User Group Operating Steps Indication of the lock Touch the infrared sensor hole ee Fingerprint sensor is power to power on the lock on LED blinks green Press button pese One beep Place any admin finger 1 time to verify Admin One beep Long press button 3 to delete A long beep LED blinks Temporary user group Fe green for 1 second Delete Succeed Note All delete operation is only valid for group se Delete Normal User Group Operating Steps Indication of the lock Touch the infrared sensor hole Fingerprint sensor is power to power on the lock on LED blinks green Press button Fr One beep Place any admin finger 1 time to verify Admin One beep Long press button 2 to delete Normal user group A long beep LED blinks green for 1 second Delete Succeed Note All delete operation is only valid for group Delete Admin Group Operating Steps Indication of the lock Touch the infrared sensor hole Fingerprint sensor is power to verify Admin Long press button 1 to delete Admin group A long beep LED blinks green for 1 second to p
3. User Manual PL10 ML10 Version 1 0 1 New lock is configured to grant ANY fingerprint access to unlock 2 The lock is equipped with mechanical keys for manual unlocking Remove mechanical keys from the package and keep them in a safe place 3 To power on the lock four alkaline AA batteries not included are required Non alkaline and rechargeable batteries ARE NOT RECOMMENDED 4 Please avoid strong light direct to the fingerprint holder otherwise the infrared sensor might be disturbed 5 The operation of setting lock has a stand by time limit of 10 seconds Without any activity lock will shut off after 10 seconds 6 Keep your fingers clean when using this lock oO O N O OC A C N n n n n a F c N O Infrared sensor hole LED Fingerprint Sensor Handle Mechanical key hole ey Battery box cover Battery Area Button 3 Temporary User sgn Button Admin user Back LED Button Delete user Button Add user d Heset Button Button 2 Normal User 9V Emergency battery interface User Introduction Admin user 10 Add delete fingerprint Enable Normal Open Unlock the door mae Umaci ie Button Definition e wem O Beet J Admin User Group Enable Normal Open Lock Status Indication Unlocking 1 Beep and electric engine makes a rolling sound for the first time which indicates that
4. nd LED blinks green 1 4 second for the third fingerprint Registration succeed v Register NEW users Note 1 The first user will be the first Admin automatically at default 2 Admin group supports 10 users you can still register 9 new Admins in next step 3 The operating steps of Register new users Press button 1 2 3 to select user group then place one new finger 3 times on the fingerprint sensor to continue register new user Register Other Admin Operating Steps Touch the infrared sensor hole to power on lock Indication of the lock Fingerprint sensor is power on LED blinks green Press button One beep Place any admin finger 1 time to verify Admin One beep Press button 1 to select Admin group One beep Place one finger 3 times on the fingerprint sensor Registration Succeed One Beep for the first two fingerprints A long beep and LED blinks green 1 second for the third fingerprint Register NEW users Note 1 Admin group supports 10 users you can still register 9 new Admin in this step 2 The operating steps of Register new users Press button 1 2 3 to select user group then place one new finger 3 times on the fingerprint sensor to continue register new user Register Normal User
5. ower on the lock DUM on LED blinks green Press button Pe One beep Place any admin finger 1 time One beep Pe Delete Succeed Note All delete operation is only valid for group Enable And Disable Normal Open Enable Normal Open Operating Steps Indication of the lock Place any registered finger De Fingerprint sensor is power once to do verification on LED blinks green Long press 1 button Alon i g beep LED blinks 3 seconds x green for 1 second Disable Normal Open Place any registered finger 1 time to disable
6. the door is open Locking Electric engine makes a rolling sound for the second time which indicates that the door is closed Initialize Lock Method 1 Method 2 Operating Steps Indication of the lock Operating Steps Press the Reset button with Delete all Temporary i Please see Delete a pin Users Temporary Users Fingerprint sensor is 4 Touch the infrared sensor hole i to power on the lock power on LED blinks Please see Delete Delete all Normal Users Normal Users green Loosen the pin Delete all Admin Users ee Please see Delete Admin Users One beep for each S Press the Dutton of 47 71 pressing back LED on ng l order blinks green Reset successfully A long beep LED blinks Initialization succeed green for 1 second Note The lock will be restored to factory defaults after initialization and the door can be opened with any fingerprint How to use mechanical key Hexagon Screw Register First Admin Operating Steps Indication of the lock Touch the infrared sensor hole Fingerprint sensor is power to power on lock on LED blinks green Press button ea One beep One Beep for the first two Place one finger 3 times on fingerprints A long beep the fingerprint sensor Es a