Home
IR Forehead Thermometer
Contents
1. IR Forehead Thermometer Include Protective Cap 1 pc User Manual pc Probe Covers 7 pcs Please read this instruction manual before use C 0123 User Manual of IR Forehead Thermometer Thank you for purchasing our IR Forehead Thermometer For a desirable use of this product be sure to read this User Manual before any operation For safe and proper use of this product be sure to read and fully understand Safety Precautions contained in this User Manual Keep this Manual with you for a convenient reference Keep this Manual in a proper way and avoid any loss SAFETY PRECAUTIONS Warning marks and symbols are contained for your safe and proper use of this product and prevention of any injury to you and others See Table below for description of warning marks and symbols A WARNING Means a possibility of personal injury in case of improper use A NOTICE Means a possibility of personal injury or property damage in case of improper use Property damage covers any damage to house family property domestic animal and pet MARKS or SYMBOLS ATTENTION Means Notice with detailed items expressed in words or figures within or beside Left one means No break Q PROHIBITION Means Forbidden with detailed items expressed in words or figures within or beside the mark Left one means General Forbidden Q MUST OBSERVE Means Obligatory with detailed items exp
2. 2 Battery in wrong polarity 1 Change new battery or 2 Adjust battery to proper polarity Battery symbol on LCD Low battery Change new battery Lo on screen result below 35 C 95 OF Thermometer rightly pointed at the eardrum Follow User s Manual to point at the eardrum Hi on screen result above 42 2 C 108 F Dirty lens Clean the lens ErrE on screen Thermometer temperature beyond the scope of 10 40 C 50 F 104 F Condition the thermometer till room temperature 10 40 C 50 104 F before measuring ErrE on screen Don t measure afterpressing Measure Follow steps in User s Manual for proper measurement ErrE on screen Errors detected during self check Consult a repairman Replace a battery Remove the battery compartment door Use only a new battery CR2032 style Replace the battery compartment tight SPECIFICATION Product Name IR Forehead Thermometer Power supply 3 Volt CR2032 Power consumption lt 0 05W for voice prompt Temperature sensing part IR sensor Measuring range 35 0 C 42 2 C 95 0 F to 108 0 F Measuring accuracy 0 2 C or 0 4 F from 36 0 C 39 0 C or 96 7 F to 102 2 F 0 3 C 0 5 F from 35 0 C 35 9 C or 95 0 F to 96 6 F from 39 1 C 42 2 C or 102 3 F to 108 0 F 7 Outer dimension 110 L
3. c F f g 7 AM PM 9 oF 4 as GLEN Cl F Z iog M c SE i AM PM Or 4 sd c F 7 oe MI c F 4 t AM PM 9 SE Ba MI Cl F d k E fa el E ri 5 AM PM s oF 4 Bb MI c F 2 A AE c F 4 AM PM c oF P 10 Meansuring Dara Record Dare Meansuring Time Temperature 2 d T MI c SR ee AF PM c F MI c F AM Pet c F AM PM acy oF 4 El A c F 4 alk AU rit Cl E pos MI c F AMEN c F I SF c F 5 AM PM oF i MI c F 4 d 2 MI c F MI c E l S MIM c F 4 2 ae Au PM c F 7 5 AM PM oF 2 i oi MI c F 4 4 e i AIN el E d 4 P MI c F 7 2i MI c F AM DEM c F f f z AM PM oF 4 ER MI c F d A MI ley F 4 ak Aur PM c F P11 Manufacturer Shenzhen Dongdixin Technology Co Ltd Authorized EC representative Shanghai International holding Corp GmbH Europe Add Eiffestrasse 80 20537 Hamburg Germany Tel 0049 40 2513175 Fax 0049 40 255726 E mail antonjin yahoo com cn
4. measurement records stored and searchable Maximum 30 sets of temperature records stored Each set has a maximum storage time of 30 days Temperature is stored together with measuring date time morning or afternoon and status day time or night time 4 Voice prompt report measurement results in C or F or current time PE Advanced operation 1 Time mode e System enters time mode when 1 Power on 2 No key is pressed for more than one minute e For normal status 1 Display time in a sequence of year month date week hour minute with a flickering stands for second 2 Press Talk to report current time 3 Press and hold Memory for 2 second to initiate setup mode 4 Press and hold Talk to switch between 12 24 hour mode e For setup mode 1 Press Talk to shift between a setting of hour minute year month and date 2 Press Memory to increase the digit 3 Press Memory subsequently to resume a normal status Unit return to time mode automatically for 1 minute after last key pressed 2 Memory search mode e A search mode can be activated by press Memory at normal time model e is displayed if no data is stored e Search number is shown for stored data available Maximum storage is 30 sets of data e Press and hold Memory to increase the digits rapidly e Unit returns to time mode automatically for 1 minute after last key pressed Recommendations 1 Mea
5. x 27 W x 35 H mm 8 Weight 66g 9 Working environment Temperature 10 40 C 50 0 F to 104 0 F Relative humidity 30 RH 80 RH 10 Storage environment Temperature 20 40 C 4 F to 104 0 F Relative humidity 30 RH 85 RH 11 EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE 12 CONTINUOUS OPERATION Dispose of used batteries with care consult your distribution center for details ACCESSORIES Protective cap 1 pc User Manual 1 pc Probe Covers 3 pcs on RO WARRANTY One year warranty is available from purchasing date excluding user caused failures listed below 1 Failure resulted in unauthorized disassembly and modification 2 Failure resulted in unexpected drop during application or transportation 3 Failure resulted in operation away from proper instruction in User Manual Present the Warrant Card with seal of distribution center include name and address for repair free Consult sales Office for service free P9 Meansuring Data Record Dare Meansuring Time Temperature l Vi MI c F 4 J X AM PM 9 oF Z A AMLA c F 2 E s AM AFA c F g t AM PM 9 Of ER MO c F ul poss MI c JE 4 J i t AM PM OF 4 MI c F A 4 ost Al c E 4 4 F AM PM 9 OF 4 MIN c F ld A MM
6. nd Once the measurement has been completed you will hear a short melody Then you will hear the result via the speaker or see it from the LCD 3 The result will be stored into memory automatically If 30 sets of memory are stored already the first set of data will be removed and others decreased by 1 with the new one at the top Note the recorded data will be removed automatically when it is recorded over 30 days 4 The maximum number of temperature taking is 3 times in a consecutive way It is possible that a proper body temperature measure is obstructed despite of a normal recovery For continuous measurement up to 4 times or above wait for 10 minutes before another measure 5 Display of measuring results A True value display for result falls between 35 42 2 C 95 108 F B HI displayed for result above 42 2 C 108 F C LO displayed for result below 35 C 95 F 6 At completion of measurement the unit automatically returns to time mode after 1 minute 7 The display will be turned off 3 minutes after last key pressed automatically Fundamental functions 1 Current date and time display Range of date display falls within Gregorian calendar year 1901 2099 time display mode includes 12 hours shift or 24 hours shift The initial time for a powered system is set at January 01 2003 2 Measurement and display of temperature Measurement ranges from 35 C 95 F to 42 2 C 108 F 3 30 sets of
7. ose any vibration or impact on the product Don t use a mobile phone nearby when the thermometer is working The forehead thermometer has been designed for practical use but is not meant to replace a visit to the doctor The forehead thermometer is only intended for measuring temperature on the forehead DO NOT USE for measuring body temperature rectally under the arm or in the mouth PRODUCT STRUCTURE Measure Measure Talk Memory Speaker Reset key Rear Front Side P4 ABC concerning ear temperature 1 What is forehead temperature Forehead temperature is the same temperature as the arterial blood supply under the skin It is the best determinate of body temperature and unaffected by the artificial errors and time delays of oral and rectal methods 2 How to take forehead temperature properly Gently touch probe to center of forehead Make sure remove anything covering the area to be measured hair hat wig and bandages Otherwise it would insulate the area resulting in falsely readings 3 Why is a forehead temperature is more accurate than ear temperature The reason why ear thermometers are considered inaccurate is because the positioning of the probe in the ear canal might affect the accuracy The forehead thermometer scans the forehead area for temperature given off by the arterial blood suppl
8. ressed in words or figures within or beside the mark Left one means General Compulsory A IMPLICATION OF SYMBOL Means Type B device P2 WARNING It is dangerous for patients to perform a self evaluation and self treatment based on the measuring results Be sure to follow doctors instruction A self evaluation may cause deterioration of diseases Don t touch or blow infrared sensor i A polluted infrared sensor may cause inaccuracy Clean a polluted infrared sensor with a soft dry cloth in a gentle manner Clean with toilet tissue or paper towel may scratch the infrared sensor causing inaccuracy Keep the machine out of children s reach A self measurement forced by children may cause ear damage For accidental swallow of battery or protective film please consult the doctor at once For temperature difference between storage area and measurement site condition the thermometer for about 30 minutes in room temperature measurement site Failing to do so may cause inaccuracy A Don t throw batteries into fire Battery is likely to explode in fire P3 RECOMMENDATIONS Don t use the product for other purpose It is not a waterproof product avoid any liquid invasion including alcohol and water It is forbidden to leave the product exposed to any chemical solvent direct sunshine or high temperature Don t drop tramp or imp
9. sure only the front of the head exposed to the environment Anything covering the area to be measured hair hat wig bandages would insulate the area resulting in falsely high readings 2 Wait about 30 seconds before measuring the same patient again to avoid excessive cooling of the skin 3 When exposed to changing room temperature the device should at least remain in the same room for 15 minutes prior to the measurement 4 Always cover the thermometer with the protective cap supplied P7 Maintenance storage and calibration Maintenance 1 Remove any stains on the body with a soft and dry cloth 2 Don t wash with water or detergent containing abrasive or benzene Storage 1 Always put the protective cap cover the probe if the unit is not in used 2 Don t leave the thermometer exposed to or at high risk of direct sunshine high temperature dampness fire flame vibration or impact 3 Remove the battery for long time of no use CALIBRATION This thermometer is calibrated at the time of manufactured If the thermometer is used according to the instruction periodic re calibration is not required If at any time you question the accuracy of the measurement please contact the retailer immediately Don t attempt to modify or reassemble the thermometer ROUBLES and TROUBLESHOOTING Troubles Checklists Counter measures No response 1 Battery used up or
10. y under the skin without worry making good position The gentle scan is comfortable and not objectionable Temperature measurements are also impacted by the type of measurement method used Rectal Ear temperature is generally 1 2 to 1 degree higher than oral temperature and axillary temperature is generally 1 2 to 1 degree lower than oral The following chart lists general temperature ranges for each method Measurement method Normal temperature range Fever temperature range Axillary under arm 95 5 98 5 F 35 3 36 9 C 98 9 F or higher 37 2 C or higher Forehead 95 0 100 4 F 35 0 38 0 C A temperature that is 1 0 1 5 F 0 6 0 8 C higher than usual It is highly recommended that you NOTED ements for some use our IR Forehead Thermometer adults may be lower than 95 0 F to establish the normal temperature 685 00 range for each person Oral 96 6 99 5 F 35 9 37 5 C 99 6 F or higher 37 6 C or higher Rectal Ear 97 7 100 3 F 36 5 37 9 C 100 4 F or higher 38 0 C or higher P 5 How to Take a Measurement 1 Remove protective cap before use and make sure lens is clean If not clean with cotton swab dipped in alcohol and let dry 2 Gently position the probe flush on the center of the forehead midway between the eyebrow and the hairline Press the Measure button once to start the measurement amp you will hear a beep sou
Download Pdf Manuals
Related Search
Related Contents
Notice d'emploi Benutzerhandbuch User manual User Manual Sartorius Wägezellen_WZA614-NC, WZA215-LC, WZA245 Electrolux 7.05 Compact Dishwasher User Manual Click to user manual Jacuzzi EV77959 User's Manual Dyno-Scan for Palm OS User Guide Ele-BOX(エレボックス) - D Copyright © All rights reserved.
Failed to retrieve file